Loading...
HomeMy WebLinkAboutSURVEYS 8.5x11 l88 TH S't. g�,21oE�1 ' � It�,r. �t��� �7 . � N 81°22'32"E • i97.60 o r •'o � T"` � 1� o * UTIIITY 8 ORAIwAGE ( �; �. EASEMENT ALL +�ROUNO �° �_ I Q , � y °` J l I � ^ ° �8 � �► � LQT 1 � 1— � � ` M � g l �0 4 � . � rt ` °� ��� � _...._-------r -- —" , � S 83°SO 3����` 196 73 �� � ��-- d ��" � � � s-- a � � � � � i � I hersby oerti �� � � fl► this ie �. cocrno.. re�res�a:.:�t;�;, of a �urtirvy of� i Lot 1, Placic �, Lalc�ri�be:, �skota Cc�u�.ty. i:i:,�asra� �ccordiu� to �he rlat tiacr�of o� Pi:a e,r�d of :3aa.•c. � ! e�d ti�t Y s� a �u:y reigiat�rod :a�9 ,u;voyflr ur:�er t'no :awa �f ths St�te of l'ic,:.esota. i , ! � ' :,vc.e L. .T�oo`s+o 1;iu:�. R^_g. bo. T734 2020 Deck Specifications 2020 Deck Specifications (Continued� • Footings must be a minimum 12"diametez and 42"below • Ledger connected to house with staggered'/2"lag screws/bolts gxade with cardboard tubes.(R403.1)Diamond piexs approved. @ 12"o.c. for joist span 14'or less and double lag screws/balts • Post/fooring connection shall be a foundarion anchor ar an @ 12"o.c.for joist spans greater than 14'with proper metal approved post holder bracket(R407.3) flashing. Other connectors allowed per manufacturer. • Post/beam eonnection shall be an approved post/beaxtr • Fasteners (screws&nails)must be corrosion resistant. Only connectox or solid wood bearing at beam-ends. No Strap��tn� ���ist hanger nails may be used in joist hangers with all holes •Wood shall be cedar,redwood,black locust,black walnut,oY filled. (Roofing nails are prohibited) preservarive treated wood.(R317) P • Special design is req'd for decks attached to house cantilever. •Guardrails muumum 36"above the finished deck boards foi • Future Porch-posts must be at outer portion of deck rims, decks more than 30"above grade. Open guaxdrails and stair beam canrilevers are not permitted and larger footings required. railings shall have intermediate rails spaced so that a 4" sphere • Lateral loads of decks shall be restrained by attaching bottom cannot pass through.(R312) Do not notch 4"x 4"posts. of deck joists to top plate of basement wall at 4locations. • Floor joist&Stair stringers spaced at 24"o.c.require min. 2" • Stair Stringer shall be attached to the deck rim with approved wood decking. Floor joists/stringers spaced at 16"o.c.may usc galvanized strapping or hangers. 5/4"wood decking. (5/4"decking may be installed diagonall� • Landings:min 36"length and width. across 16"o.c.joists) Composite decking shall be installed per � • Handrail 34"-38"above nosing. 1 '/4"to 2 5/8"cross secrion& manufacturer's specificarions. conrinuous. Stairs w/4 or more risers require handrail. • Beams/girders shall not bear on ledger but on sill or top plate • Stairway:min. 36"width;l0"min tread,7'/0"max rise with of wall.Beam splices shall only occur over centex of posts. max 3/8"variation;6'-8"min headroom.