HomeMy WebLinkAboutItem 06.o Date: Item No.
RAVEN LAKE THIRD ADDITION
PRELIMINARY AND FINAL PLAT AND VARIANCE
Proposed Action
Staff recommends adoption of the following motion: Move to approve a resolution approving the Raven
Lake Third Addition preliminary and final plat and a variance from Section 10-3-5.V of the Subdivision
Ordinance and adopt the findings of fact.
Overview
NITI, LLC and Ron Clark Construction representatives are requesting approval of the Raven Lake Third
Addition preliminary and final plat and house pad elevation variance. Raven Lake Third Addition
proposes two single family lots and three outlots on 8.8 acres of land located on the west side of Jaguar
Path, east of Kenwood Trail (CSAH 50).
The Planning Commission held a public hearing on the Raven Lake Third Addition preliminary and final
plat at their December 18, 2014 meeting and unanimously recommended approval. There was public
comment from one neighboring homeowner. The Parks, Recreation and Natural Resources Committee
also recommended unanimous approval of the preliminary and final plat at their December 17, 2014
meeting. The developer has extended City Council consideration of the preliminary and final plat and
variance applications several times while marketing the property for sale.
Primary Issues to Consider
• What is the relationship between the Raven Lake Third Addition and Lakeville Pointe plats?
Ron Clark Construction is purchasing the subject property and will be developing the Raven Lake Third
Addition plat. The 49 unit apartment building proposed with the Lakeville Pointe preliminary plat and
CUP will be located on Outlot B, Raven Lake Third Addition.
Supporting Information
• Plat Resolution
• Variance Form
• Variance Findings of Fact
• Signed Development Contract and Warranty Deed
• December 18, 2014 Planning Commission meeting minutes
• December 17, 2014 Parks, Recreation and Natural Resources Committee meeting minutes
• Planning report (revised June 15, 2016) and Engineering report (revised May 9, 2016)
Financial Impact: $ Budgeted: Y☐ N☐ Source:
Related Documents: (CIP, ERP, etc.):
Envision Lakeville Community Values: A Home for All Ages and Stages of Life
Report Completed by: Daryl Morey, Planning Director
June 20, 2016
Zoning and Subdivision Ordinances
(Reserved for Dakota County Recording Information)
CITY OF LAKEVILLE
DAKOTA COUNTY, MINNESOTA
RESOLUTION NO. __________
RESOLUTION APPROVING THE PRELIMINARY AND FINAL PLAT OF
RAVEN LAKE THIRD ADDITION
WHEREAS, the owner of the plat described as Raven Lake Third Addition has
requested preliminary and final plat approval; and
WHEREAS, the preliminary and final plat was reviewed by the Planning
Commission and the Parks, Recreation and Natural Resources Committee; and
WHEREAS, the preliminary and final plat is acceptable to the City.
NOW, THEREFORE, BE IT RESOLVED by the Lakeville City Council:
1. The preliminary and final plat of Raven Lake Third Addition is hereby
approved subject to the development contract and security requirements.
2. The Mayor and City Clerk are hereby directed to sign the final plat mylars and
the development contract.
3. The City Clerk is directed to file a certified copy of this resolution with the
Dakota County Recorder.
ADOPTED by the Lakeville City Council this 20th day of June 2016.
CITY OF LAKEVILLE
BY: _____________________
Matt Little, Mayor
ATTEST:
________________________
Charlene Friedges, City Clerk
STATE OF MINNESOTA )
(
CITY OF LAKEVILLE )
I hereby certify that the foregoing Resolution No. _______ is a true and correct copy of
the resolution presented to and adopted by the City Council of the City of Lakeville at a
duly authorized meeting thereof held on the 20th day of June 2016 as shown by the
minutes of said meeting in my possession.
________________________
Charlene Friedges, City Clerk
(SEAL)
(Reserved for Dakota County Recording Information)
CITY OF LAKEVILLE
DAKOTA COUNTY, MINNESOTA
RAVEN LAKE THIRD ADDITION VARIANCE
1. Permit. Subject to the terms and conditions set forth herein, the City of
Lakeville hereby grants a variance from Section 10-3-5.V of the Lakeville Subdivision
Ordinance concerning house pad elevations in conjunction with the plat of Raven Lake
Third Addition.
2. Property. The variance is for the following described property in the City of
Lakeville, Dakota County, Minnesota:
Lots 1 and 2, Block 1, Raven Lake Third Addition
3. Conditions. The variance is issued subject to the following conditions:
a. The developer shall grade an overflow swale between the two homes within the
drainage and utility easement located along the shared side lot line.
b. The driveways are graded to direct runoff away from the garage opening and the
house.
DATED: June 20, 2016
CITY OF LAKEVILLE
BY: ________________________
Matt Little, Mayor
BY: ________________________
Charlene Friedges, City Clerk
STATE OF MINNESOTA )
(
COUNTY OF DAKOTA )
The foregoing instrument was acknowledged before me this ________ day of
______________, 2016, by Matt Little, Mayor and by Charlene Friedges, City Clerk of
the City of Lakeville, a Minnesota municipal corporation, on behalf of the corporation.
______________________
Notary Public
STATE OF MINNESOTA )
(
CITY OF LAKEVILLE )
I hereby certify that the foregoing variance is a true and correct copy of the variance
presented to and adopted by the City Council of the City of Lakeville at a duly
authorized meeting thereof held on the 20th day of June, 2016 as shown by the minutes
of said meeting in my possession.
_______________________
Charlene Friedges, City Clerk
(SEAL)
DRAFTED BY:
The City of Lakeville
20195 Holyoke Avenue
Lakeville, MN 55044
1
CITY OF LAKEVILLE
DAKOTA COUNTY, MINNESOTA
RAVEN LAKE THIRD ADDITION VARIANCE
FINDINGS OF FACT AND DECISION
On December 18, 2014, the Lakeville Planning Commission met at its regularly scheduled
meeting to consider the application of NITI, LLC for a variance from Section 10-3-5.V of the
Subdivision Ordinance in conjunction with the preliminary plat of Raven Lake Third Addition.
The Planning Commission conducted a public hearing on the variance application preceded by
published and mailed notice. The applicant was present and the Planning Commission heard
testimony from all interested persons wishing to speak. The City Council hereby adopts the
following:
FINDINGS OF FACT
1. The subject property is located in Comprehensive Planning Districts 1 and 2, which guides
the two single family lots proposed with Raven Lake Third Addition for low density
residential use.
2. The subject site is zoned RS-2, Single Family Residential District.
3. Legal description of the property is:
Lots 1 and 2, Block 1, Raven Lake Third Addition
4. Chapter 6 of the City of Lakeville Zoning Ordinance provides that a variance may not be
issued unless failure to grant the variance will result in practical difficulties and unless
certain criteria are satisfied. The criteria and our findings regarding them are:
a. That the variance would be consistent with the Comprehensive Plan.
Finding: The two single family lots proposed with the Raven Lake Third Addition plat are
consistent with the low density residential use guided by the Comprehensive Land Use
Plan.
b. That the variance would be in harmony with the general purposes and intent of
this ordinance.
Finding: The two single family lots proposed with the Raven Lake Third Addition plat can
achieve gravity sanitary sewer flow and positive drainage away from the foundations of
the houses, meeting the intent of Chapter 10-3-5.V of the Subdivision Ordinance.
c. That the plight of the landowner is due to circumstances unique to the property
not created by the landowner.
Finding: The design of the Raven Lake Second Addition plat approved in 1997 included
partial right-of-way for an eyebrow cul-de-sac to be located on the west side of Jaguar
Path that would provide street frontage and access for the development of future single
family lots on the Raven Lake Third Addition property. The Subdivision Ordinance no
2
longer allows eyebrow cul-de-sacs and staff does not support the construction of an
eyebrow cul-de-sac to serve the two single family lots in Raven Lake Third Addition.
d. That the purpose of the variance is not exclusively economic considerations.
Finding: Grading impacts and retaining wall construction would be reduced with the
granting of the variance.
e. That the granting of the variance will not alter the essential character of the
neighborhood in which the parcel of land is located.
Finding: The single family homes to be constructed in Raven Lake Third Addition will fit
in nicely with the surrounding Raven Lake single family neighborhood.
f. That the requested variance is the minimum action required to eliminate the
practical difficulty.
Finding: The proposed building floor elevations for the two single family lots in Raven
Lake Third Addition are supported by Engineering staff provided the developer grades
an overflow swale between the two homes within the drainage and utility easement
located along the shared side lot line and provided the driveways are graded to direct
runoff away from the garage opening and the house.
g. Variances may not be approved for any use that is not allowed under this title for
property in the zone where the affected person’s land is located.
Finding: Single family homes are a permitted use in the RS-2 District.
5. The report dated December 11, 2014 (revised June 15, 2016) prepared by Planning Director
Daryl Morey is incorporated herein.
DECISION
The City Council approves the variance if the form attached hereto.
DATED: June 20, 2016
CITY OF LAKEVILLE
BY: __________________________
Matt Little, Mayor
BY: __________________________
Charlene Friedges, City Clerk
Planning Commission Meeting Minutes
December 18, 2014 Page 3
8. Fulford Group LLC
Acting Chair Drotning opened the public hearing to consider the application of James
Fulford, Fulford Group, LLC, for the vacation of a 10 -foot wide public drainage and utility
easement located at 21350 Cedar Avenue.
The easement vacation is being requested in association with the Fulford Group 1st Addition
preliminary and final plat, comprehensive plan amendment and rezoning approved by the
City Council on November 17, 2014 and is needed for the expansion of the building to the
east of the easement. Utility companies in the area were notified and no objections were
received.
Ms. Jenson stated that Planning Department staff recommends approval of the public
drainage and utility easement vacation subject to one stipulation as described in the
December 11, 2014 planning report.
Acting Chair Drotning opened the hearing to the public for comment.
There were no comments from the audience.
Motion was made by Blee, seconded by Swenson to close the public hearing at 6:11
p.m.
Ayes: Swenson, Maguire, Drotning, Blee
Nays: 0
There was no further discussion from the Planning Commission.
Motion was made by Blee, seconded by McGuire, to recommend to City Council approval
of the vacation of a 10 -foot wide public drainage and utility easement located at 21350
Cedar Avenue, subject to one stipulation as described in the December 11, 2014 planning
report:
1. The drainage and utility easement shall be vacated upon City Council approval of the
Fulford Group 1st Addition final plat.
Ayes: Swenson, Maguire, Drotning, Blee
Nays: 0
This item will be considered by the City Council at their January 5, 2015 meeting.
9. Raven Lake Third Addition
Acting Chair Drotning opened the public hearing to consider the application of NITI, LLC for
the following located west of Jaguar Path, east of Kenwood Trail (CSAH 50), and north of
185th Street (CSAH 60):
A. Preliminary and final plat of two (2) single family lots to be known as Raven Lake
Third Addition.
Planning Commission Meeting Minutes
December 18, 2014 Page 4
B. Variance from Section 10-3-5.V of the Subdivision Ordinance concerning single
family lot pad elevations.
Steve Norton representing NITI, LLC presented a brief overview of the request. The applicant
is proposing to combine two existing parcels to be platted into two single family lots, and
three outlots.
Planning Director Daryl Morey presented the planning report. Mr. Morey stated that the
variance request was discussed at the September 18, 2014 Planning Commission work
session. The subdivision ordinance requires house pads to be 18" above adjacent roadways
to accommodate gravity sanitary sewer and stormwater drainage. Staff supports the
developer's request for a variance for the foundation elevation. An electric transmission line
bisects the northwest corner of the property and creates additional challenges with the plat.
An eyebrow cul-de-sac was originally proposed for the property but that type of cul-desac is
no longer allowed by the City of Lakeville. Outlot C, the unpaved cul-de-sac, will be deeded
to the City for utilities and snow storage.
Staff supports the variance request and has identified seven criteria of the Zoning Ordinance
which have been met by the developer. Staff is recommending approval of the Raven Lake
Third Addition preliminary and final plat and variance subject to four stipulations listed in
the December 11, 2014 planning report.
Acting Chair Drotning opened the hearing to the public for comment.
Mike Robb lives next door to the property and asked if there were covenants or
requirements for building a certain size home in the neighborhood and also asked if the City
would deed property for the driveways to the homeowners.
Motion was made by Maguire, seconded by Blee, to close the public hearing at 6:22
p.m.
Ayes: Swenson, Maguire, Drotning, Blee
Nays: 0
Planning Director Morey stated that the zoning ordinance specifies minimum floor area
requirements for single-family homes. The homeowners' driveways will be able to access
Jaguar Path through Outlot C. Staff can check with the City Attorney to determine if an
encroachment agreement would be needed. Mr. Norton stated that there are no covenants
proposed for Raven Lake Third Addition since this addition has no relationship to the
previous Raven Lake additions. The developer intends to sell the vacant lots.
Motion was made by Maguire, seconded by Blee, to recommend to City Council approval
of the Raven Lake Third Addition preliminary and final plat of two (2) single family lots; and
variance from Section 10-3- 5.V of the Subdivision Ordinance concerning single family house
pad elevations subject to the following four stipulations:
1. The recommendations listed in the December 11, 2014 engineering report.
Planning Commission Meeting Minutes
December 18, 2014 Page 5
2. The recommendations of the Parks, Recreation and Natural Resources Committee.
3. Outlots A and C shall be deeded to the City with the final plat.
4. A custom grading plan, erosion control plan, tree preservation plan, and soil survey
must be submitted with the building permit for Lots 1 and 2.
Ayes: Drotning, Blee, Swenson, Maguire
Nays: 0
The City Council will consider final approval of Raven Lake Third Addition preliminary and
final plat at their January 20, 2015 meeting.
10. Berres Ridge
Acting Chair Drotning opened the public hearing to consider the application of Berres Ridge
Development, LLC for the following located north of 202nd Street (CSAH 50), west of
Hamburg Avenue and east of Highview Avenue:
A. Preliminary plat of 366 single family residential lots to be known as Berres Ridge;
B. Comprehensive Plan amendment to bring approximately 21 acres of land into the
current Municipal Urban Service Area (MUSA); and
C. Zoning Map amendments for the following:
1. Rezone a portion of the property from RS -3, Single Family Residential District to
RS -4, Single Family Residential District;
2. Rezone a portion of the property from P/OS, Park/Open Space District to RS -3,
Single Family Residential District; and
3. Rezone that portion of the property to be brought into the current MUSA from
RA, Rural/Agricultural District to RS -3, Single Family Residential District.
John Anderson, representing Berres Ridge Development, LLC, presented a brief overview.
The developer plans to begin construction on the first of six phases in the spring of 2015.
Most of the property is owned by the Berres family, however some additional property is
planned to be purchased from St. John's Lutheran Church.
Associate Planner Kris Jenson presented the planning report. This is a request for approval of
a preliminary plat and comprehensive plan amendment which includes bringing property
into the MUSA and amending the Zoning Map. The current and proposed zoning was
highlighted. There are three existing home sites on the property. The Berres homestead is
being incorporated into the preliminary plat as Ms. Berres is choosing to remain in her home
at this time. The home's driveway will be relocated to Heath Avenue and the home will be
connected to City sewer and water. The other two homesteads will be platted into 10 -acre
parcels and replatted as part of a future phase. An EAW was completed and a negative
declaration was approved by the City Council. The density and average lot size is consistent
with the requirements of the zoning ordinance. The City's comprehensive park plan does
not identify parkland in this area. The Parks, Recreation and Natural Resources Committee
recommended a cash contribution to satisfy the park dedication requirement. The Dakota
County Plat Commission has reviewed and approved the preliminary plat.
CITY OF LAKEVILLE
PARKS, RECREATION & NATURAL RESOURCES COMMITTEE
MEETING MINUTES
December 17, 2014
Chair Kelly called the meeting to order at 6:00 p.m. in Council Chambers at City Hall.
Members Present: Lori Bovitz, Judy Hayes, Scott Kelly, Howard Lovelace, Bob Swan,
Tom Goodwin
Members Absent: Jeanne Peterson
Staff Present: Environmental Resources Manager Mac Cafferty, Recording Secretary
Tamara Wallace
2. Approval of November 19 minutes
Minutes were approved as presented.
3. Citizen comments
There were no citizen comments.
4. Staff report
Environmental Resources Manager Mac Cafferty conducted the meeting and
reported that Parks and Recreation Director, Brett Altergott, is currently putting
together a work plan for the committee that will guide discussions around the topics
discussed at the joint Council-PRNRC meeting.
5. Barres Ridge Development Preliminary Plat
Staff reviewed the Barres Ridge Development preliminary plat and discussed storm
water treatment, the greenway corridor, tree preservation, park and trail placement,
and drainage issues.
Motion made by Tom Goodwin, seconded by Lori Bovitz to recommend to City
Council approval of the Barres Ridge Development preliminary plat, subject to the
recommendations as presented by City staff.
Ayes: unanimous
6. Raven Lake Third Addition Preliminary & Final Plat
Staff reviewed the Raven Lake Third Addition preliminary and final plat and
discussed wetland impact, trails, and tree preservation.
Motion made by Tom Goodwin, seconded by Howard Lovelace to recommend
to City Council approval of the Raven Lake Third Addition preliminary and final plat,
subject to the recommendations as presented by City staff.
Ayes: unanimous
7. Other Business
The environmental department is still looking for an alternate for the Black Dog
Watershed meetings held the third Wednesday of the month from 5:00-6:00 p.m.
City of Lakeville
Planning Department
Memorandum
To: Planning Commission
From: Daryl Morey, Planning Director
Date: December 11, 2014 (revised June 15, 2016)
Subject: Packet Material for the December 18, 2014 Planning Commission Meeting
Agenda Item: Raven Lake Third Addition Preliminary and Final Plat and Variance
INTRODUCTION
Peter Eisenhuth, on behalf of NITI, LLC, has submitted preliminary and final plat applications
and plans for Raven Lake Third Addition, which consists of two single family lots and three
outlots on 8.8 acres of land located on the west side of Jaguar Path, east of Kenwood Trail
(CSAH 50). In conjunction with the preliminary and final plat, the developer has submitted a
variance application to allow a reduction in the proposed house pad elevations required by
Section 10-3-5.V of the Subdivision Ordinance.
The Raven Lake Third Addition preliminary and final plat plans have been distributed to
Engineering and Parks and Recreation staff as well as the Parks, Recreation and Natural
Resources Committee for review.
EXHIBITS
Exhibit A – Aerial Location Map
Exhibit B – Zoning Map
Exhibit C – Preliminary Plat
Exhibit D – Final Plat
Exhibit E – Boundary and Topographic Survey
Exhibit F – Grading, Drainage & Erosion Control Plan
Exhibit G – Dakota County Plat Commission letter
Raven Lake Third Addition Preliminary and Final Plat
December 18, 2014 Planning Commission Meeting
2
PLANNING ANALYSIS
Existing Conditions. The subject property is vacant land with rolling topography, a wetland
in the center of the site, and numerous significant trees on the easterly portion. A 75 foot
wide electric transmission line easement cuts across the northwest corner of the property.
Zoning and Adjacent Land Uses. The east half of the subject property is zoned RS-2, Single
Family Residential District and the west half is zoned O-R, Office/Residential Transition
District. Only the east half is proposed to be platted into lots at this time. The adjacent land
uses and zoning are as follows:
North – NTB minor auto repair use, wetland complex (Argonne Village PUD and P/OS)
East – Single family homes and twinhomes (RS-2 and RST-1)
South – Single family homes, wetland complex (RS-2 and P/OS)
West – Kenwood Trail and multi-family homes (ROW and RH-1)
Premature Subdivision Criteria. A preliminary plat may be deemed premature if any of the
criteria listed in Chapter 10-2-4-1 of the Subdivision Ordinance exist. The criteria pertain to a
lack of adequate drainage, water, streets, sanitary sewer and public service capacity (i.e.
recreation facilities, police and fire protection), or inconsistency with the Comprehensive Plan,
Capital Improvement Plan or Metropolitan Council Environmental Services policies. The
Raven Lake Third Addition preliminary plat is not considered a premature subdivision given
these criteria.
Density. The Raven Lake Third Addition preliminary and final plat proposes two single family
lots. The two single family lots total 3.26 acres (excluding outlots and ROW) resulting in a
gross and net density of 0.61 dwelling units/acre.
Lots. The two single family lots in Raven Lake Third Addition are subject to the RS-2 District
lot requirements, which are as follows:
Lot Area: 15,000 sq. ft.
Lot Width: 100 feet
The two proposed lots meet the RS-2 District lot area and lot width requirements.
Outlots. The Raven Lake Third Addition preliminary and final plat proposes three outlots as
follows:
Outlot A: Wetland complex (1.28 acres). Will be deeded to the City with the final plat.
Outlot B: Future development (3.26 acres). Will be retained by the developer.
Outlot C: Street/utility ROW (0.01 acres). Will be deeded to the City with the final plat.
Raven Lake Third Addition Preliminary and Final Plat
December 18, 2014 Planning Commission Meeting
3
Setbacks. The two single family lots in Raven Lake Third Addition are subject to the RS-2
District building setback requirements, which are as follows:
Front: 30 feet
Rear: 30 feet
Side: 15 feet
Proposed house pads are shown on the grading, drainage & erosion control plan. The
proposed house pads meet the RS-2 District building setback requirements.
Streets. The Raven Lake Third Addition preliminary and final plat abuts Kenwood Trail (CSAH
50), which is designated as a minor arterial in the City’s Transportation Plan. A 150 foot
right-of-way width is required by Dakota County for Kenwood Trail. The preliminary and final
plat shows the required right-of-way dedication for Kenwood Trail. Kenwood Trail was
upgraded to a four lane divided roadway adjacent to the subject property in 2015 in
conjunction with the CSAH 50/60 roundabout project. The preliminary and final plat
approved by the Dakota County Plat Commission at their December 15, 2014 meeting.
The Raven Lake Third Addition preliminary and final plat abuts Jaguar Path, which is
designated as a minor collector in the City’s Transportation Plan. The required right-of-way
for Jaguar Path was dedicated with the Raven Lake Second Addition final plat. The design of
the Raven Lake Second Addition plat included partial right-of-way (platted as an outlot and
deeded to the City) for an eyebrow cul-de-sac to be located on the west side of Jaguar Path
that would provide street frontage and access for the development of future single family lots
on the Raven Lake Third Addition property. The Subdivision Ordinance no longer allows
eyebrow cul-de-sacs and staff does not support the construction of an eyebrow cul-de-sac to
serve the Raven Lake Third Addition development. However, platting the right-of-way
(Outlot C) in an eyebrow configuration allows enough street frontage for the development of
two single family lots meeting the RS-2 District lot width requirement.
Grading, Drainage, Erosion Control, and Utilities. Grading, drainage, erosion control, and
utilities plans have been submitted for Raven Lake Third Addition. The plans have been
reviewed by engineering staff and their comments are contained in the May 9, 2016
engineering report. The two single family lots are proposed to be custom graded. As such, a
custom grading plan, erosions control plan, tree preservation plan, and soil survey must be
submitted with the building permit for each lot.
Tree Preservation. An inventory of significant trees is shown on the boundary and
topographic survey. Since the two single family lots are proposed to be custom graded, an
individual tree preservation plan must be submitted for each lot. Tree preservation security is
required for Lots 1 and 2 and Outlots A and B.
Raven Lake Third Addition Preliminary and Final Plat
December 18, 2014 Planning Commission Meeting
4
Wetlands. A wetland delineation was prepared in conjunction with the preliminary plat. No
wetland impacts are proposed. The wetland and wetland buffer is located within Outlot A,
which will be deeded to the City with the final plat. Natural area signs must be installed on
Lots 1 and 2 as discussed in the December 11, 2014 engineering report.
Parks and Trails. Park dedication for the two single family lots in Raven Lake Third Addition
will be met by a cash contribution. When Outlot B is final platted into lots, the developer will
be responsible for 5/8ths of the cost of both a greenway corridor trail and a ten foot wide
MPTW along the east side of CSAH 50 as identified in the Parks, Trails and Open Space Plan.
The Parks, Recreation and Natural Resources Committee reviewed the Raven Lake Third
Addition preliminary and final plat at their December 17, 2014 meeting and unanimously
recommended approval.
Variance. Chapter 10-3-5.V of the Subdivision Ordinance requires that the proposed
elevation of the top of the foundation and the garage floor for residential dwellings shall be a
minimum of 18 inches (or 3%) above the grade of the center of the street. This requirement is
in place to ensure positive stormwater drainage away from the house and into the storm
water drainage system located within the public street.
The developer’s engineer, Rehder & Associates, has indicated that the two single family lots in
Raven Lake Third Addition can achieve gravity sanitary sewer flow and positive drainage away
from the foundations of the houses, meeting the intent of Chapter 10-3-5.V of the Subdivision
Ordinance. In addition, grading impacts and retaining wall construction would be reduced.
The variance request was discussed at the September 18, 2014 work session and the Planning
Commission expressed support because the request meets the variance criteria of Section
11-6-5 of the Zoning Ordinance as follows:
A. That the variance would be consistent with the Comprehensive Plan.
The Comprehensive Plan guides the property for low density residential uses as proposed
with the Raven Lake Third Addition preliminary and final plat.
B. That the variance would be in harmony with the general purposes and intent of this
ordinance.
The two single family lots in Raven Lake Third Addition can achieve gravity sanitary sewer
flow and positive drainage away from the foundations of the houses, meeting the intent of
Chapter 10-3-5.V of the Subdivision Ordinance.
C. That the plight of the landowner is due to circumstances unique to the property not
created by the landowner.
Raven Lake Third Addition Preliminary and Final Plat
December 18, 2014 Planning Commission Meeting
5
The design of the Raven Lake Second Addition plat approved in 1997 included partial right-
of-way for an eyebrow cul-de-sac to be located on the west side of Jaguar Path that would
provide street frontage and access for the development of future single family lots on the
Raven Lake Third Addition property. The Subdivision Ordinance no longer allows eyebrow
cul-de-sacs and staff does not support the construction of an eyebrow cul-de-sac to serve
the two single family lots in Raven Lake Third Addition. Platting the right-of-way in an
eyebrow configuration allows enough street frontage for the development of two single
family lots meeting the RS-2 District lot width requirement.
D. That the purpose of the variance is not exclusively economic considerations.
Grading impacts and retaining wall construction would be reduced with the granting of
the variance.
E. That the granting of the variance will not alter the essential character of the
neighborhood in which the parcel of land is located.
The single family homes to be constructed in Raven Lake Third Addition will fit in nicely
with the surrounding Raven Lake single family neighborhood.
F. That the requested variance is the minimum action required to eliminate the practical
difficulty.
The proposed building floor elevations for the two single family lots in Raven Lake Third
Addition are supported by Engineering staff provided the developer grades an overflow
swale between the two homes within the drainage and utility easement located along the
shared side lot line and provided the driveways are graded to direct runoff away from the
garage opening and the house.
G. Variances may not be approved for any use that is not allowed under this title for
property in the zone where the affected person’s land is located.
Single family homes are a permitted use in the RS-2 District.
Staff has prepared findings of fact that support granting the variance.
RECOMMENDATION
Planning Department staff recommends approval of the Raven Lake Third Addition
preliminary and final plat and variance subject to the following stipulations:
Raven Lake Third Addition Preliminary and Final Plat
December 18, 2014 Planning Commission Meeting
6
1. The recommendations listed in the May 9, 2016 engineering report.
2. Outlots A and C shall be deeded to the City with the final plat.
3. A custom grading plan, erosion control plan, tree preservation plan, and soil survey
must be submitted with the building permit for Lots 1 and 2.
City of Lakeville
Public Works – Engineering Division
Memorandum
To: Daryl Morey, Planning Director
From: Alex Jordan, Project Engineer
McKenzie L. Cafferty, Environmental Resources Manager
John Hennen, Parks and Recreation Director
Copy: Zach Johnson, City Engineer
Jerilyn Erickson, Finance Director
Gene Abbott, Building Official
Date: May 9, 2016
Subject: Raven Lake Third Addition
• Preliminary Plat Review
• Final Plat Review
• Preliminary and Final Grading and Erosion Control Plan Review
• Preliminary and Final Utility Plan Review
• Preliminary and Final Tree Preservation Plan Review
BBAACCKKGGRROOUUNNDD
NITI, LLC has submitted a preliminary and final plat named Raven Lake Third Addition. The
proposed subdivision is located east of and adjacent to Kenwood Trail (CSAH 50) and west of
and adjacent to Jaguar Path. The parent parcels consist of two metes and bounds parcels
zoned O-R and RS-2 (PID No. 220130001010 and 221185000380). The Developer is dedicating
0.92 acres of Kenwood Trail (CSAH 50) right-of-way.
The preliminary and final plat consists of two (2) single-family lots within one block and three
(3) outlots on 8.80 acres.
The outlots created with the preliminary and final plat shall have the following use:
Outlot A: Wetland complex; to be deeded to the City (1.28 acres)
Outlot B: Future Development; to be retained by the Developer (3.26 acres)
Outlot C: Additional Jaguar Path Right-of-Way; to be deeded to the City (0.01 acres)
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 22 OOFF 88
The proposed subdivision will be completed by:
Developer: NITI, LLC
Engineer: Rehder and Associates, Inc.
SSIITTEE CCOONNDDIITTIIOONNSS
The Raven Lake Third Addition site contains undeveloped land with a large number of
significant trees scattered throughout the site. Existing overhead transmission lines are
located within a 75-foot private easement that crosses Kenwood Trail and through the
northeast corner of Outlot B. A large wetland complex exists within the center of the site. The
land generally slopes downward south and to the existing wetland area.
SSTTRREEEETT AANNDD SSUUBBDDIIVVIISSIIOONN LLAAYYOOUUTT
Kenwood Trail (CSAH 50)
Raven Lake Third Addition is located east of and adjacent to Kenwood Trail, a minor arterial
County roadway as identified in the City’s Transportation Plan. The County’s ½ right-of-way
requirement is 75-feet. The Developer is dedicating the necessary right-of-way with the final
plat.
Kenwood Trail adjacent to the parent parcels was reconstructed in 2015 to a four lane divided
roadway with Dakota County Project Nos. 50-17 and 60-21 and City Project No. 09-07. The
cash fee for the future upgrade of Kenwood Trail has not been collected on the parent
parcels. The Developer shall provide a cash fee for the re-construction of Kenwood Trail, at
the time Outlot B is final platted into lots and blocks. The cash fee will be based on the rate in
effect at the time of final plat.
Jaguar Path
Raven Lake Third Addition is located west of and adjacent to Jaguar Path, a minor collector
roadway as identified in the City’s Transportation Plan. The right-of-way for Jaguar Path was
dedicated with the Raven Lake Second Addition final plat. The Developer is dedicating
additional area for Jaguar Path as Outlot C, Raven Lake Third Addition, west of and adjacent
to Outlot C, Raven Lake Second Addition. Outlot C, Raven Lake Second Addition was platted
and dedicated to the City for a future “eyebrow” cul-de-sac that was identified to allow for the
future development of the parent parcels. City ordinance no longer allows the construction of
eyebrow cul-de-sacs due to the increased maintenance difficulty and cost. Therefore, the
Developer is not required to construct the cul-de-sac.
CCOONNSSTTRRUUCCTTIIOONN AACCCCEESSSS
Construction traffic access and egress for site grading and building construction shall be
restricted to Jaguar Path, by way of Kenwood Trail (CSAH 50).
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 33 OOFF 88
PPAARRKKSS,, TTRRAAIILLSS AANNDD SSIIDDEEWWAALLKKSS
There are no proposed sidewalks or trails associated with the Raven Lake Third Addition
improvements.
The Park Dedication Fee has not been collected on the parent parcels and shall be paid at the
time of final plat approval. The Park Dedication Fee is based on the rate in effect at the time of
final plat approval and is calculated as follows:
2 units x $3,781.00/dwelling unit = $7,562.00
Single-Family Dwelling Units Park Dedication Fee Rate Total
The Parks, Trails and Open Space Plan identifies a 10-foot wide trail on the east side of
Kenwood Trail. This trail was constructed in 2015 with City Project No. 09-07. The Developer
shall provide a cash fee for its 5/8ths share of the construction costs (excluding grading and
restoration) of the bituminous trail, based on the contractor’s bid prices for the project, at the
time Outlot B is final platted into lots and blocks. The cash fee is calculated as follows:
$13,179.54 x 5/8 = $8,237.21
Trail Construction Cost (excluding grading
and restoration)
Developer’s Cost Share Total
UUTTIILLIITTIIEESS
SSAANNIITTAARRYY SSEEWWEERR AANNDD WWAATTEERRMMAAIINN
Raven Lake Third Addition is located within subdistrict OL-56110 and OL-56120 of the
Orchard Lake sanitary sewer district as identified in the City’s Comprehensive Sanitary Sewer
Plan. Wastewater will be conveyed via existing trunk sanitary sewer to the MCES Farmington
Interceptor and continue to the Empire Wastewater Treatment Facility. The downstream
facilities have sufficient capacity to serve the proposed residential subdivision.
Sanitary sewer and watermain within Jaguar Path were installed as part of the Raven Lake
Second Addition improvements. The Developer shall install the two sanitary sewer and water
services from the existing sanitary sewer and watermain located within Jaguar Path right-of-
way, as shown on the final utility plans. A $5,000 security will be required with the final plat
for the connection to the public sanitary sewer and watermain.
The Lateral Sanitary Sewer Access charge is required for the sanitary sewer within Kenwood
Trail. The fee will be required at the time Outlot B is final platted into lots and blocks and will
be based on the rate in effect at the time of final plat approval.
A homestead was previously located at 18030 Kenwood Trail and was connected to City
sewer. This homestead was demolished and the sewer service was permanently abandoned
in 2010. The Developer shall be eligible to receive one SAC Unit credit at the time of building
permit issuance for the demolished homestead that connected to City sewer.
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 44 OOFF 88
The Sanitary Sewer Availability Charge has been collected on the parent parcels and will not
be required with the final plat.
The Lateral Watermain Access Charge is required for the watermain located within Kenwood
Trail. The fee will be required at the time Outlot B is final platted into lots and blocks and will
be based on the rate in effect at the time of final plat.
Final sewer and water service connection locations and sizes will be reviewed by City staff
with the final construction plans.
OOVVEERRHHEEAADD LLIINNEESS
The private existing overhead transmission lines, located at the northwest corner of Outlot B
are not required by City Code to be buried and shall remain with the Raven Lake Third
Addition improvements.
DDRRAAIINNAAGGEE AANNDD GGRRAADDIINNGG
Raven Lake Third Addition is located within subdistricts OL-12A and OL-13 of the Orchard
Lake drainage district as identified in the City’s Water Resources Management Plan.
Development of Raven Lake Third Addition does not include the construction of stormwater
management basins. The proposed development will create less than an acre of impervious
surface; therefore, the Developer is not required to install a stormwater management system,
consistent with City ordinance. The entire site will drain to the existing wetland in Outlot A.
The runoff from the imperious surfaces will be treated by the existing vegetation within
Outlot A. The Developer is required to grade the area of the right-of-way from the back of
curb to the building pads prior to the issuance of building permits. A $1,000 security will be
required with the final plat for grading and erosion control of the site.
The proposed garage floor elevations are located below the elevation at the center of Jaguar
Path. The Developer shall grade an overflow swale between the two buildings within the
drainage and utility easement, prior to issuance of building permits. In addition, the
driveways shall be graded to direct runoff away from the garage opening and building.
The grading plan indicates that the two lots within Raven Lake Third Addition will be custom
graded by prospective homeowners. Consistent with Subdivision Ordinance requirements, all
custom graded lots shall submit a custom grading plan, erosion control plan, tree
preservation plan, soil survey and pre-approved site/building plan prior to the issuance of a
building permit. The maximum slope for grading shall be 3 horizontal feet per 1 vertical foot.
The grading plan shall provide for an area with a slope not greater than ten percent
extending not less than a depth of twenty feet from the rear line of the building pad the
entire width of the building pad. The Developer shall provide a $10,000 security to ensure
that the vacant lots are graded to meet these requirements and with positive drainage away
from the building, including side-yard swales that direct runoff toward the wetland in Outlot
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 55 OOFF 88
A, and that the driveways are constructed. The grading specifications shall also indicate that
all embankments meet FHA/HUD 79G specifications.
RREETTAAIINNIINNGG WWAALLLLSS
Any retaining wall necessary for the building construction shall be privately owned and
maintained and located outside of the public drainage and utility easements. Any retaining
wall that is greater than 4-feet in combined height shall be designed by a registered
geotechnical or structural engineer, consistent with MnDOT requirements. The Building
Official must approve the retaining wall design and plans.
SSTTOORRMM SSEEWWEERR
There are no proposed storm sewer improvements associated with the Raven Lake Third
Addition development. The public storm sewer was installed with the Raven Lake Second
Addition improvements.
Any draintile construction, including perimeter draintile required for building footings, which
is deemed necessary during construction shall be the Developer’s responsibility to install and
finance. In addition, existing draintile is located behind the back of curb along Jaguar Path.
The Developer shall provide a $1,000 security to preserve the functionality of this draintile
system.
The Trunk Storm Sewer Area Charge has not been collected on the parent parcels and shall be
paid at the time of final plat approval. The Trunk Storm Sewer Area Charge is calculated as
follows:
Gross Area of Raven Lake Third Addition 381,150.00 s.f.
Less Area of Outlot A (Wetland Complex) (-) 55,892.00 s.f.
Less Area of Outlot B (Future Development) (-) 141,828.00 s.f.
Less Area of Kenwood Trail Right-of-way (-) 40,838.00 s.f.
Total = 142,592.00 s.f.
142,592.00 s.f. x $0.178/s.f. = $25,381.37
Net Area of Raven Lake
Third Addition
Area Charge Total
The Developer will receive a credit to the Trunk Storm Sewer Area Charge for deeding Outlot
A to the City, consistent with City policy. The credit is based on the area of the outlot and is
calculated at the rate of $5,500.00 per acre, and will be applied to the Raven Lake Third
Addition final plat cash fees. The credit is calculated as follows:
1.28 acres x $5,500/acre = $7,040.00
Total Area of Outlot A Per Acre Credit Total
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 66 OOFF 88
FEMA FLOODPLAIN ANALYSIS
Raven Lake Third Addition is shown on the Flood Insurance Rate Map (FIRM) as Zone X by the
Federal Emergency Management Agency (FEMA). Based on this designation, there are no
areas in the plat located within a Special Flood Hazard Area (SFHA), as determined by FEMA.
WWEETTLLAANNDDSS
A wetland delineation was completed for the site. No impacts are proposed to any wetlands.
All wetland and wetland buffers are located in an outlot that will be dedicated to the City with
final plat. Natural Area signs will be installed along the rear property lines (7 locations) for
Block 1, Lots 1 and 2.
TTRREEEE PPRREESSEERRVVAATTIIOONN
A tree inventory was completed for the site. Since the lots are custom graded with the house
an individual tree preservation plan will be required for each lot with the building permit.
Block 1 Lots 1 & 2 2 Lots @ $1,500.00 each = $3,000.00
Outlots A & B 2 Outlots @ $1,000.00 each = $2,000.00
Total = $5,000.00
EERROOSSIIOONN CCOONNTTRROOLL
An erosion control plan has been submitted and includes the following:
• A seed/mulch specification that meets City requirements.
• All 3:1 slopes and swales will be seeded and stabilized with fiber blanket.
• Silt fence installed around disturbed areas.
• Inlet protection is included in the plans. Wimco Road Drain or equivalent will be used
on all street catch basins and Royal Infra-safe or equivalent will be used for all rear lot
catch basins.
Additional erosion control measures may be required during construction as deemed
necessary by City staff. Additional measures shall be installed and maintained by the
developer. The streets must be cleared of debris at the end of each day. Street sweeping
must be done weekly or more often as needed. All streets must be maintained to provide
safe driving conditions.
The grading plan indicates that the two vacant lots within Raven Lake Third Addition will be
custom graded by prospective builders/homeowners. All custom graded lots shall submit a
custom grading plan, erosion control plan, tree preservation plan, soil survey and pre-
approved site/building plan prior to the issuance of a building permit.
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 77 OOFF 88
SSEECCUURRIITTIIEESS
The Developer shall provide a Letter of Credit as security for the Developer-installed
improvements relating to Raven Lake Third Addition.
CONSTRUCTION COSTS
Connect to Existing Sanitary Sewer $2,000.00
Connect to Existing Watermain $3,000.00
Erosion Control and Grading Certification for
Right-of-Way and Emergency Overflow Swale
$5,000.00
SUBTOTAL - CONSTRUCTION COSTS $ 10,000.00
OTHER COSTS
Developer’s Design (6.0%) $ 600.00
Developer’s Construction Survey (2.5%) 250.00
City’s Legal Expense (0.5%) 50.00
City Construction Observation (7.0%) 700.00
Developer’s Record Drawing (0.5%) 50.00
Custom Graded Lots 10,000.00
Preserve Existing Draintile System 1,000.00
Tree Preservation 5,000.00
Natural Area Signs 700.00
Lot Corners 500.00
SUBTOTAL - OTHER COSTS $18,850.00
TOTAL PROJECT SECURITIES $ 28,850.00
The Developer shall post a security to ensure the final placement of iron monuments at
property corners with the final plat. The security is $100.00 per lot and outlot for a total of
$500.00. The City shall hold this security until the Developer’s land surveyor certifies that all
irons have been placed following site grading.
CCAASSHH FFEEEESS
A cash fee for one-year of streetlight operating expenses shall be paid at the time of final plat
approval and is calculated as follows:
2 units x $8.42/unit/qtr. x 4 qtrs. = $67.36
Dwelling Units Streetlight Operating Fee Total
A cash fee for one-year of environmental resources expenses shall be paid at the time of final
plat approval and is calculated as follows:
2 units x $7.75/unit/qtr. x 4 qtrs. = $62.00
RRAAVVEENN LLAAKKEE TTHHIIRRDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY AANNDD FFIINNAALL PPLLAATT
MMAAYY 99,, 22001166
PPAAGGEE 88 OOFF 88
Dwelling Units Environmental Resources Fee Total
A cash fee for the preparation of record construction drawings and for upgrading the City
base map shall be paid at the time of final plat approval and is calculated as follows:
5 units
x $75.00/unit
= $375.00
Lots/Outlots City Base Map Updating Fee Total
The Developer shall submit the final plat and construction drawings in an electronic format.
The electronic format shall be either a .dwg file (AutoCAD) or a .dxf format.
The Developer shall also pay a cash fee for City Engineering Administration. The fee for City
Engineering Administration will be based on three percent (3.00%) of the estimated
construction costs, or $300.00.
CASH REQUIREMENTS
Park Dedication Fee $ 7,562.00
Trunk Storm Sewer Area Charge 25,381.37
Streetlight Operating Fee 67.36
Environmental Resources Expenses 62.00
City Base Map Updating Fee 375.00
City Engineering Administration (3.00%) 300.00
SUBTOTAL - CASH REQUIREMENTS $33,747.73
CREDITS TO THE CASH REQUIREMENTS
Outlot A (Trunk Storm Sewer Fund) $7,040.00
SUBTOTAL - CREDITS TO THE CASH REQUIREMENTS = $7,040.00
TOTAL CASH REQUIREMENTS $26,707.73
RREECCOOMMMMEENNDDAATTIIOONN
Engineering recommends approval of the preliminary plat, final plat, grading and erosion
control plan, utility plan and tree preservation plan for Raven Lake Third Addition, subject to
the requirements and stipulations within this report.