HomeMy WebLinkAboutItem 06.gDate: August 15, 2016
Item No.
AGREEMENT WITH ALPHA VIDEO FOR THE PURCHASE
OF A BROADCAST PIX VIDEO SWITCHER
Proposed Action
Staff recommends adoption of the following motion: Move to approve an agreement with
Alpha Video for the purchase and installation of a Broadcast Pix video switcher and associated
hardware and software.
Overview
The cable control room includes integrated live production equipment that is used to route,
relay, create and deliver live video. The current equipment is outdated, over ten years old, and
is based on Windows XP which is no longer supported by Microsoft. In addition, the table top
control panel, which is over 18 years old, is broken and is not repairable. The control room
improvements will also include upgrading the sound processor from analog to digital. The
sound processor eliminates fluctuations in audio and keeps it at a steady level for our viewers.
Primary Issues to Consider
Was this equipment included in the 2o16 budget?
• The 2ox6 budget included $30,78$ to cover the cost of purchasing and installing the
equipment. Alpha Video is proposing to supply and install the equipment for $28,140.
Supporting Information
Quote from Alpha Video dated June 8, 2o16
Purchase Agreement with Alpha Video
Financial Impact: $ 28,140 Budgeted: YD N❑ Source: Communications/PEG Funds
Related Documents: (CIP, ERP, etc.):
Envision Lakeville Community Values: Good Value for Public Services
Report Completed by: Allyn G. Kuennen, Assistant City Administrator
i
7690 Golden Triangle Drive, Eden Prairie, MN 55344
Phone: 952-896-9898 - Fax 952-896-9899 - Visit us at www.alphavideo.com
Quotation
Date
I Quote #
I Cust #
06/08/16
1 AMQ31584-02
I LAK007
We are an equal opportunity employer
ID # Item
Description
Qty
Unit Price
Prepared For:
1 940
Broadcast Pix Slate to Mica Upgrade
Sales Representative:
Tim Klausier
Phone:
(952)985-4417
Mike Pouh
City of Lakeville
20195 Holyoke Ave
Fax:
(952)985-4499
Sales Executive
Lakeville, MN 55044
Terms:
NET 30
952-841-3365
USA
Ship via:
Best Way
mike.pouh@alphavideo.com
ID # Item
Description
Qty
Unit Price
Ext. Price
1 940
Broadcast Pix Slate to Mica Upgrade
1
$13,300.00
$13,300.00
2 175
Broadcast Pix Fluent Rapid CG LT
1
$1,335.00
$1,335.00
3 241
Broadcast Pix Rack Rails
1
$175.00
$175.00
4 642
Broadcast Pix Ext Warranty
1
$1,585.00
$1,585.00
5 S81713
Winsted 3 Bay 24"D Work Surface - 3" Beveled Front with Slatye
1
$930.00
$930.00
Grey Insert (EBBB)
6 S81716
Winsted 3 Bay 24"D Work Surface - 3" Beveled Front with Slatye
1
$1,165.00
$1,165.00
Grey Insert - Corner (BCBCB)
7
Alpha Video Miscellaneous Materials
1
$665.00
$665.00
8
Alpha Video Installation Labor
1
$3,350.00
$3,350.00
SubTotal
$22,505.00
9 951903211
TC Electronic Loudness Pilot 2xSDl
1
$5,635.00
$5,635.00
Shipping charges are not included and will be billed at actual cost.
Sub Total
$28,140.00
Sales tax is not included and will be billed at actual.
Sales Tax
$0.00
A 3% convenience will be added for credit card payments.
Shipping
$0.00
Total
$28,140.00
Accepted by: Date: PO:
All information contained within this quote is valid for the next 30 days. Thereafter, all prices and applicable charges are subject to change.
MINIMUM 15% RESTOCKING FEE WITH ORIGINAL PACKAGING.
06/10/16
CONFIDENTIAL
Page 1 of 1
1 of 1
BROADCAST PIX
UPGRADE
DATE:
June 8, 2418
Prepared for:
CITY OF LAKEVILLE
Presented by:
Account Manager — Mike Pouh
Project Engineer — Mike Ford
Introduction
Alpha Video and Audio Inc. is pleased to present this proposal for the Broadcast Pix
production switcher upgrade for the City of Lakeville. This statement of work document
outlines the equipment and services that Alpha Video will deliver and the responsibilities of
The City of Lakeville for a successful implementation.
Broadcast Pic Upgrade
Alpha Video will provide and install a new Broadcast Pix Mica production switcher as an
upgrade to the existing Broadcast Pix Slate Switcher. The new HD switcher will be changed
out while continuing to use the existing control surface. As the existing system is wired for
HD -SDI signal flow, Alpha will rewire the new switcher with the same configuration making
necessary minor changes. Alpha will verify the use of existing options installed on the old
switcher and transfer to the Mica system.
Alpha will work with the City to help move existing shows and databases from the existing
switcher to the new, but this should be a task completed by the City.
Console Upgrade
In addition to the switcher upgrade, Alpha Video will also provide and install a new work
surface for the existing Winsted System 85 console. The new 24" deep shelf will be a 3"
beveled oak work surface with a slate grey insert. The work surface will be a combination of
two pieces (1 — 3 bay straight surface and 1 — 3 bay 90 deg. corner piece).
Additional Installation Information or Requirements
This proposal assumes that all existing equipment required for the functionality of the system
is in proper operating condition and without defect. tf any of the required existing equipment
is not in proper operating condition, a change order may be required for the functionality
outlined in this proposal. This proposal also assumes that work can be carried out
continuously throughout the day with limited to no interruptions. If daily interruptions do occur
during on site work, change orders may be required based on installation inefficiencies
related to these interruptions.
Standards of Integration
General
• System and components will be installed in a neat and professional manner.
• All equipment will be new and blemish free unless otherwise noted in this
document.
• All rack equipment will be installed using proper manufacture supplied mounting
hardware.
• All rack blank spaces will be filled with either a blank or vent panel depending on
need.
• All racks will have proper ventilation to prevent heat buildup and increase
equipment life expectance.
2
Wiring and Cables
• All rack cabling will be bundled neatly with cable ties or hook & loop depending
on requirements.
• Low and high voltage cabling will be separated in according with NFPA 70
(National Electric Code) 2014 specifications.
• All cabling in conduit will comply with the conduit fill specifications in NFPA 70
(National Electric Code) 2014.
• Proper strain relief at connections and joints will be used.
• Sufficient service loops shall be provided for all above ceiling elements, above
racks, in racks or in cable trays so that components may be minimally moved or
serviced without cable strain.
• All connectors are sized to fit the specific cabling and are installed in accordance
with manufacture specifications.
• All permanently installed cabling will be labeled with permanent CAD generated
labels.
Installer Testing and Adjustments
• Proper grounding will be verified on all equipment.
• Video displays shall be properly aligned and free from distortion.
• Audio shall be free of distortion, hums, buzzes or pops.
• Loudspeaker systems shall be tested and equalized to provide uniform frequency
response.
• Control system program shall be tested for proper system operation and shall be
free of glitches. Any issues will be brought to the attention of the programmer for
correction.
Training
Alpha Video will provide up to 1 hour of system training to no more than three key users on
basic system operation and troubleshooting. The training will be provided once the system is
fully functional and will be continuous during one day unless otherwise noted above.
Advance system training for the use and configuration of the Broadcast Pix switcher will be
be provided.
Documentation
Alpha Video will provide shop drawings that reflect the final system design. Upon project
completion, a full set of "D" size as -built drawings will be provided, which will include
components of the video, audio and control systems and any architectural documentation
used during the installation. Those drawings will become property of The City of Lakeville
upon receipt of final payment for this project.
Project Management
Alpha Video will appoint a project manager that will be the main point of contact for The City
of Lakeville regarding this project. The project manager will manage the installation timeline
and coordinate work with any additional trades involved in this installation.
3
Installation can only begin when the project manager has been notified that construction
progress has reached a point that electronic equipment can be installed in a secure and
clean job site.
Change Requests
When the scope of work is agreed upon, any changes to that scope must be requested as a
change order. Change requests shall be submitted in written form so that both parties fully
understand the request. Any costs resulting from change orders shall be the responsibility of
The City of Lakeville.
System Warranty and Support
Alpha Video offers a standard 90 -day warranty on all systems installations. During the 90
days, Alpha Video will facilitate system service, phone support or repair at no charge for
labor, travel, and/or shipping on any Alpha Video installed system or component. All system
hardware is covered under the terms and conditions of each manufacturer's warranty. Alpha
Video, at its option, may repair or replace any product or part of the products, which proves
defective because of failure, under normal use, for the length of the 90 -day warranty period.
An optional extension for a full 1 -year support agreement is available for purchase during the
90 -day warranty period.
Phone support is available Monday through Friday during regular business hours of 8:00
a.m. to 5:00 p.m. Alpha Video's office number is 952-896-9898. Calls will be returned within
a four-hour period. If the issue cannot be rectified over the phone a technician will be on site
within 24 — 48 hours. Alpha Video will not be open on various holidays that occur during a
Monday - Friday work week. The City of Lakeville agrees that prompt and full access to the
system will be granted to Alpha Video at any time Alpha Video is on-site to service the
system.
Products not provided by Alpha Video but included in this installation will not be covered by
this warranty. Alpha Video is not responsible for any failure of equipment that is connected to
or caused by Client furnished equipment. The warranty coverage will commence on date the
Certificate of Completion form is signed by both Alpha Video and The City of Lakeville.
Service issues after the 90 -day period will be handled as time, materials and travel, plus fees
associated with such work unless a warranty extension has been purchased. This warranty
does not cover system misuse, reconfiguration or negligence on the part of The City of
Lakeville.
Client Responsibilities
This statement of work indicates the responsibilities of Alpha Video and Audio Inc. As in any
system installation, this project contains a number of customer responsibilities. They include,
but are not limited to:
• Any High Voltage AC necessary
• Any necessary conduits, back boxes, or structural supports for mounted
equipment
• One key point of contact for control system design verification
• Owner furnished equipment described above (PC, PC monitor, laptops, etc.)
• Provide access to the job site during normal business hours (lam to 5pm M -F)
• Coordination with Client staff for training times
• Disposal of existing equipment, cabling, and racks
• IP Address's for all networked devices prior to onsite installation.
Client Sign -Off
As an appointed representative of The City of Lakeville, I hereby agree with and approve the
above statement of work including all outlined Client Responsibilities. A purchase order for
this project, in verbal or written form indicates acceptance of this statement of work.
Date:
Company:
Name:
Signature: