Loading...
HomeMy WebLinkAbout148247 Energy Code Compliance Certificate  Date Certificate Posted x Passive (No Fan ) Active (With fan and monometer or other system monitoring device ) Location (or future location) of Fan: Other Please Describe Here X R-10 X R-21 X R-21 X R-21 X R-49 X R-30 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60,000 Capacity in Gallons: Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct Not required per mech. code 6"Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 43VP50E2 DX13SN030 Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces R-410A Make-up Air Select a Type Rheem Domestic Water Heater Gas MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER /EER Model Heating System Gas Daikin DM92SS0803B Manufacturer Daikin 50 Output in Tons:2.5 Appliances Cooling System To t a l R - V a l u e o f a l l T y p e s o f In s u l a t i o n Type: Check All That Apply Min e r a l F i b e r b o a r d THERMAL ENVELOPE Insulation Location Fo a m , C l o s e d C e l l Fo a m O p e n C e l l Wall No n o r N o t A p p l i c a b l e Fi b e r g l a s s , B l o w n Fi b e r g l a s s , B a t t s Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Fuel Type Solar Heat Gain Coefficient (SHGC):0.30 Describe other insulated areas RADON CONTROL SYSTEM Rim Joist (2nd Floor+) 0.30 Building envelope air tightness: 6 MIL POLY - 4" AGG INTERIOR INTERIOR Below Entire Slab Rig i d , E x t r u d e d P o l y s t y r e n e Rig i d , I s o c y n u r a t e Perimeter of Slab on Grade Ceiling, flat ATTIC EXTERIOR SEALANT Rim Joist (1st Floor) Windows & Doors Ceiling, vaulted 66Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 150 Combustion Air Select a Type Location of duct or system: 28,40044,418 Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 27,236 Residential Load Calculation Heating Loss Bay Windows or cantilevered areas Floors over unconditioned area Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor Robert Thomas Homes MN License Number BC644819 City Mailing Address of the Dwelling or Dwelling Unit LakevilleSpirt of Brandtjen Farm 16th, Lot 17, Block 1 Builders Associaton of Minnesota version 101014