Loading...
HomeMy WebLinkAboutItem 06.r Date: Item No. KENWOOD HILLS 2ND ADDITION FINAL PLAT AND PUD AMENDMENT Proposed Action Staff recommends adoption of the following motion: Move to approve a resolution approving the Kenwood Hills 2nd Addition final plat and an ordinance amending the Kenwood Hills PUD. Overview Kenwood Hills, LLC (a/k/a Homestead Partners) representatives are requesting approval of the Kenwood Hills 2nd Addition final plat and PUD amendment. The Kenwood Hills PUD consists of 45 detached townhome units located west of Kenwood Trail (CSAH 50) at Jurel Way. The Kenwood Hills 2nd Addition final plat adjusts the detached townhome unit lot lines to better accommodate dwelling unit design, allowing the decks to be located within the unit lot and not encroach into the HOA common lots. The Kenwood Hills 2nd Addition final plat does not increase the number of lots in the Kenwood Hills development. The PUD amendment will allow a reduced front yard setback for the detached townhomes fronting Jurel Way. The Kenwood Hills preliminary plat, Comp. Plan amendment and rezoning were approved by the City Council on December 1, 2014. The Kenwood Hills final plat was approved by the City Council on April 6, 2015 and the first amendment to the Kenwood Hills PUD, to reduce the setback between buildings from 20 feet to 10 feet, was approved by the City Council on January 19, 2016. The Planning Commission held a public hearing on the Kenwood Hills 2nd Addition PUD amendment at their September 8, 2016 meeting. There was no public comment. The Planning Commission unanimously recommended approval of the PUD amendment. Primary Issues to Consider • Why is a trail on the west side of Jurel Way no longer required? • What design flexibilities have been approved with the Kenwood Hills PUD? Supporting Information • Staff response to primary issues to consider • Final plat resolution • Ordinance amending the Kenwood Hills PUD • Signed second amendment to the Kenwood Hills development contract • September 8, 2016 draft Planning Commission meeting minutes • September 14, 2016 planning report (revised) Financial Impact: $ Budgeted: Y☐ N☐ Source: Related Documents: (CIP, ERP, etc.): Envision Lakeville Community Values: A Home for All Ages and Stages of Life Report Completed by: Daryl Morey, Planning Director September 19, 2016 Subdivision Ordinance, Kenwood Hills PUD Staff Response to Primary Issues to Consider • Why is a trail on the west side of Jurel Way no longer required? The developer is constructing (extending) the sidewalk on the east side of Jurel Way within the Kenwood Hills development. The Comp. Plan amendment approved with the Kenwood Hills preliminary plat in 2014 reduced the development density of the subject property from high density residential to low/medium density residential. Staff has determined that a trail on the west side of Jurel Way is no longer needed due to the reduction in the number of units being developed. In conjunction with the elimination of this trail, the developer is requesting a reduced setback for the detached townhome units that front Jurel Way from 25 feet to 20 feet. Since construction of the trail is no longer required, the developer must reimburse the City for the credit provided by the City with the initial Kenwood Hills development contract. The credit reimbursement is $4,185 and amounts to 3/8ths (City portion) of the cost of constructing the trail. An amendment to the Kenwood Hills development contract is included with the Kenwood Hills 2nd Addition final plat to reflect the trail credit reimbursement. In exchange for not requiring the construction (extension) of this trail, the developer will be required to remove the existing dead-end trail segment located west of the Southfork Village 3rd Addition private sidewalk connection to the existing trail on the west side of Jurel Court. In addition, the developer has agreed to have the Kenwood Hills HOA maintain the sidewalk on the east side of Jurel Way. This will be reflected in revised HOA documents that will be submitted to the City prior to release of the Kenwood Hills 2nd Addition final plat mylars. • What design flexibilities have been approved with the Kenwood Hills PUD? The subject property was rezoned to PUD, Planned Unit Development in conjunction with the City Council’s approval of the Kenwood Hills preliminary plat in 2014. The PUD allows flexibility in the site design to reduce grading, wetland and significant tree impacts due to the physical constraints affecting the development of the property, including wetlands, steep slopes, and a 75 foot wide electric transmission line easement that bisects the property. The existing and proposed design flexibilities include exterior building material requirements, the allowance of two private drives, reduced building setbacks, and the allowance of a temporary off-premise subdivision identification sign. These PUD flexibilities are included in the ordinance amending the Kenwood Hills PUD. (Reserved for Dakota County Recording Information) CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA RESOLUTION NO. __________ RESOLUTION APPROVING THE FINAL PLAT OF KENWOOD HILLS 2ND ADDITION WHEREAS, the owner of the plat described as Kenwood Hills 2nd Addition has requested final plat approval; and WHEREAS, the Kenwood Hills 2nd Addition final plat is a re-plat of the Kenwood Hills final plat to adjust the detached townhome unit lot lines; and WHEREAS, the Kenwood Hills 2nd Addition final plat does not increase the number of lots in the Kenwood Hills development; and WHEREAS, the Kenwood Hills 2nd Addition final plat is consistent with the approved preliminary plat; and WHEREAS, the Kenwood Hills 2nd Addition final plat is acceptable to the City. NOW, THEREFORE, BE IT RESOLVED by the Lakeville City Council: 1. The final plat of Kenwood Hills 2nd Addition is hereby approved subject to the second amendment to the Kenwood Hills development contract and the ordinance amending the Kenwood Hills PUD. 2. The Mayor and City Clerk are hereby directed to sign the second amendment to the Kenwood Hills development contract, the ordinance amending the Kenwood Hills PUD, and the Kenwood Hills 2nd Addition final plat mylars. 3. The City Clerk is directed to file a certified copy of this resolution with the Dakota County Recorder. DATED this 19th day of September 2016. CITY OF LAKEVILLE BY: _____________________ Matt Little, Mayor ATTEST: ________________________ Charlene Friedges, City Clerk STATE OF MINNESOTA ) ( CITY OF LAKEVILLE ) I hereby certify that the foregoing Resolution No. _______ is a true and correct copy of the resolution presented to and adopted by the City Council of the City of Lakeville at a duly authorized meeting thereof held on the 19th day of September 2016, as shown by the minutes of said meeting in my possession. ________________________ Charlene Friedges, City Clerk (SEAL) ORDINANCE NO._______ CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA AN ORDINANCE AMENDING THE KENWOOD HILLS PLANNED UNIT DEVELOPMENT (PUD) DISTRICT THE CITY COUNCIL OF THE CITY OF LAKEVILLE ORDAINS: Section 1. Legal Description. The legal description of the property included in the Kenwood Hills PUD District is as follows: Lots 1-13, Block 1, Lots 1-23, Block 2, and Lots 1-12, Block 3, Kenwood Hills. Section 2. Kenwood Hills PUD District. The Kenwood Hills PUD District shall be subject to the requirements of the RST-2, Single and Two Family Residential District except for the following: A. Exterior building finish (Section 11-57-19.C.4.b and c of the Zoning Ordinance). B. The allowance of two private drives. C. The following building setbacks shall apply: Base Lot – 30 feet, except Lots 1 and 11, Block 3 as shown on the approved site plan Street ROW – 25 feet, except Lots 1 and 16-22, Block 2 at 20 feet Private Drives – 25 feet Guest Parking – 15 feet Between Buildings – 10 feet D. A temporary off-premise subdivision identification sign located at the project entrance off of Kenwood Trail (CSAH 50) within Outlot A, Southfork Village 3rd Addition and subject to the requirements of Section 11-23-15.X.2 of the Zoning Ordinance. Section 3. Effective Date. This ordinance shall be effective upon its passage by the City Council. Adopted by the Lakeville City Council this 19th day of September, 2016. CITY OF LAKEVILLE BY: _______________________ Matt Little, Mayor ATTEST: ___________________________ Charlene Friedges, City Clerk MEMORANDUM TO: Daryl Morey FROM: D. Daniel Licht, AICP DATE: 14 September 2016 RE: Lakeville – Kenwood Hills 2nd Addition TPC FILE: 135.01 BACKGROUND Homestead Partners, LLC has submitted revised PUD Development Stage plans for Kenwood Hills, which consists of 45 detached townhome dwellings within 17.7 acres of land located west of Kenwood Trail (CSAH 50) at Jurel Way. On 1 December 2014 the City Council approved a Comprehensive Plan amendment for Low-Medium Density residential uses, rezoning to PUD District, preliminary plat and PUD Development Stage Plan for Kenwood Hills. The City Council approved an amendment to the preliminary plat and PUD Development Stage Plan on 19 January 2016 to establish a minimum setback of 10 feet between dwelling units. The developer has identified additional issues with the configuration whereby the proposed dwelling units cannot be adequately accommodated within the final platted unit lots. The developer is proposing an amendment of the PUD Development Stage Plan and the Kenwood Hills 2nd Addition final plat to modify the site plans to better accommodate the dwelling unit design. Exhibits: A. Location Map B. Final Plat C. Grading Plan D. Utility Plan E. Landscape Plan (3 pages) F. Tree Inventory G. Site Plan 2 ANALYSIS Existing Conditions. There are severe physical constraints effecting the development of the subject site including steep slopes and wetlands. There is also a 75 foot wide electric transmission line easement bisecting the property that affects the site design for any proposed land use. The applicant has designed their development within the constraints of the existing natural conditions of the site and the utility easement and the City has based the approved Comprehensive Plan amendment, rezoning to PUD and PUD District performance standards on the feasibility of developing the site in consideration of these constraints. Zoning. The subject site is zoned PUD, Planned Unit Development based upon the standards of the RST-2 District except as specifically modified by the approved PUD Development Stage Plan. In revising the PUD Development Stage Plan, the developer is proposing to increase the area of the individual unit lots within which the detached townhouse dwellings are to be constructed and modify the required setback from public streets and private drives as discussed in subsequent paragraphs. Setbacks. The table below lists the setbacks required for the detached townhouse dwellings within the base RST-2 District, as required by the approved PUD Development Stage Plan, and as proposed with the amendment of the preliminary plat, PUD Development Stage Plan, and final plat: Minimum Setback RST-2 Approved Proposed Base Lot 30ft. Less than 30ft. 30ft., except Lot 6, Block 1 and Lots 1 and 11, Block 3 as shown on site plan Street 30ft. 25ft. 25ft., except Lot 1 and Lots 16-22, Block 2 at 20ft Private Drive 30ft. 25ft. 25ft. Between Bldgs. 20ft. 10ft. 10ft. Guest Parking 15ft. 15ft. 15ft. The applicant is requesting a reduction in the required setback from the public right-of-way on the west side of Jurel Way, south of Jurel Court. The setback approved with the PUD Development Stage Plan was already reduced from 30 feet to 25 feet. However, the approved building envelope for Lots 1 and 16 through 22, Block 2 is not adequate to accommodate the proposed dwellings. The lack of depth is due in part to the 66 foot wide right-of-way for Jurel Way. As noted below, this right-of-way would be consistent with that required for a minor collector street, but Jurel Way will function as a local street due to the reduced density of the Kenwood Hills development versus a medium or high density development as originally guided 3 on the 2008 Comprehensive Land Use Plan. As with the approved setback reduction, the additional five foot reduction requested now will serve to minimize the depth of site grading beyond the right-of-way and private drives to avoid impacts to the existing steep slopes of the subject site. Streets. The subject site is accessed at its northeast corner by the extension of Jurel Way. The Transportation Plan designates Jurel Way as a minor collector roadway. With the reduction in density proposed to be developed within the subject site, traffic volumes utilizing Jurel Way would not be at minor collector street levels. As such, the extension of Jurel Way was approved as designed to be a local street with a 32 foot wide section within a 66 foot right-of-way. The approved PUD Development Stage Plan provided for extension of the existing eight foot trail and five foot sidewalk on the west and east sides of Jurel Way, respectively. In conjunction with the amendment of the PUD Development Stage Plan, the developer is requesting that the extension of the trail on the west side of Jurel Way not be required. The elimination of the trail will facilitate a proposed reduction in the front yard setback maintaining visibility along the street for when vehicles may be parked in the driveways. With the environmental constraints of the subject site effectively reducing the depth of the building pad and reduced population density of the development based on the approved Comprehensive Plan amendment, City staff supports removal of the planned trail west of Jurel Court. The segment between Jurel Court and Kenwood Trail (CSAH 50) is to remain. In exchange for the City not requiring a trail on the west side of Jurel Way west of Jurel Court, the PUD amendment will require the Kenwood Hills HOA maintain the sidewalk on the east side of Jurel Way within the Kenwood Hills plat and adjacent City owned outlot to the east. Trails. The approved Kenwood Hills final plat credited the developer for 3/8ths of the cost of construction for the planned trail along the west side of Jurel Way. Since the trail is no longer to be required, the developer is required to pay back the credit, which was $4,185.00. City staff is further recommending that the developer remove the existing segment of trail located east of the Kenwood Hills plat and west of the Southfork Village 3rd Addition sidewalk located west of Jurel Court in consideration of the City not requiring extension of the trail through Kenwood Hills. Homeowners Association. Lot 13, Block 1, Lot 23, Block 2 and Lot 12, Block 3 are common open space lots and include the private drives. These lots must be owned by a homeowners association as required by Section 11-57-17 of the Zoning Ordinance to provide for long-term maintenance. Documents establishing the homeowners association were submitted with the Kenwood Hills final plat application. The developer will need to submit revised homeowners association documents addressing the change in the legal description of the development as Kenwood Hills 2nd Addition prior to City Council consideration of the application. Landscape Plan. The developer has submitted a landscape plan illustrating front yard plantings along the public streets and private drives and typical foundation plantings. The proposed 4 plantings comply with the material type and size requirements of Section 11-21-9.C of the Zoning Ordinance. Subdivision Identification Sign. The amended PUD Development Stage Plan identifies a subdivision area identification sign on Lot 23, Block 2 at the southeast corner of Jurel Way and Jurel Circle. Section 11-23-15.X.1 of the Zoning Ordinance allows this sign to be a maximum of 100 square feet in area with a height of up to 10 feet. A temporary subdivision identification sign is proposed at the project entrance and subject to Section 11-23-15.X.2 of the Zoning Ordinance for a sign with a maximum area of 64 square feet and height up to eight feet. The temporary sign may be displayed for up to three years or all of the lots are sold. Both the permanent and temporary signs require a permit as outlined in Section 11-23-5 of the Zoning Ordinance. Grading Plan. The submitted plans include a revised grading plan that is subject to review and approval by the City Engineer. In conjunction with the revised grading plan, the developer has submitted a survey of trees within the proposed construction limits for the development. The existing wetlands and wetland buffer required by Section 11-16-13.C.1 of the Zoning Ordinance are platted within outlots that have been deeded to the City in accordance with Section 11-16- 13.C.1.d of the Zoning Ordinance. The proposed amendment of the PUD Development Stage Plan and the Kenwood Hills 2nd Addition final plat does not affect wetlands, wetland buffers, or wetland setbacks. Utility Plan. The developer has submitted a revised utility plan that is subject to review and approval by the City Engineer. The proposed amendment of the PUD Development Stage Plan and the Kenwood Hills 2nd Addition final plat does not affect utilities. Easements. The approved final plat provided for dedication of drainage and utility easements as required by Section 10-4-4 of the Subdivision Ordinance. There is an existing 75 foot wide electric utility easement bisecting the subject site. The easements dedicated with the approved final plat are not affected by the proposed amendment of the PUD Development Stage Plan and the Kenwood Hills 2nd Addition final plat. CONCLUSION The proposed amendment of the Kenwood Hills PUD Development Stage Plan and the Kenwood Hills 2nd Addition final plat is consistent with the goals of the Comprehensive Plan and the intent of the requirements established by the Zoning Ordinance, in consideration of the environmental constraints within the subject site. The developer must address the following issues prior to consideration of the application by the Planning Commission: 1. The following principal building setbacks shall apply to the Kenwood Hills PUD, except as indicated on the PUD Development Stage Plan: 5 Setback Base Lot 30ft., except Lot 6, Block 1 and Lots 1 and 11, Block 3 as shown on site plan Street 25ft., except Lots 1 and 16-22, Block 2 at 20ft Private Drive 25ft Between Bldgs. 10ft Guest Parking 15ft 2. The Kenwood Hills HOA shall maintain the sidewalk on the east side of Jurel Way within the final plat and adjacent to Outlot A, Southfork 3rd Addition. 3. The developer shall remove the portion of the existing trail located on the northwest side of Jurel Way located east of the Kenwood Hills plat and west of the Southfork Village 3rd Addition sidewalk located west of Jurel Court. 4. The developer shall reimburse the City the $4,185.00 that was credited to them with the Kenwood Hills development agreement for the City’s 3/8th share of the construction of the trail within the Kenwood Hills plat. 5. The developer shall submit revised Kenwood Hills HOA documents addressing the change in the legal description of the development as Kenwood Hills 2nd Addition, subject to review by the City Attorney and approval of the City Council. 6. Installation of subdivision signs as allowed by Section 11-23-15.X of the Zoning Ordinance shall require issuance of a sign permit. 7. The revised grading plan shall be subject to review and approval of the City Engineer. 8. The revised utility plan shall be subject to review and approval of the City Engineer. c. Justin Miller, City Administrator Zachary Johnson, City Engineer John Hennen, Parks and Recreation Director Roger Knutson, City Attorney Tom Bakritges, Homestead Partners, LLC PUD RH-1 P/OS RH-1 P/OS RH-1 O-R RS-2 P/OS PUD P/OS PUD C-3 RS-3 RM-1 RS-2 K E N W O O D T R L 181ST ST W K E N W O O D T R L JUR E L W A Y J A G U A R P A T H JARL CT JUREL CT ORCHARDTRL J AV A T R L K E N R I C K A V E K E N R I C K A V E ± City of Lakeville Location and Zoning Map Kenwood Hills Final Plat EXHIBIT A NW 1 / 4 SW 1 / 4 SE 1 / 4 NE 1 / 4 Vicinty Map Sec 13, Twp 114, Rng 21 SHEET 2 OF 2 SHEETS LOUCKS SCALE IN FEET 0 40 EXHIBIT B C0.1 C3.1 C3.2 C4.1 C4.2-C4.6 C5.1-C5.3 C8.1-C8.3 L1.1 L1.2 L1.3 COVER SHEET GRADING PLAN SWPP PLAN UTILITY PLAN STREET/STORM SEWER PLAN & PROFILES SAN. SEWER/WATER PLAN & PROFILES CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS TREE INVENTORY PLAN Todd W. McLouth - PE of the State of Minnesota. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws 20383 License No.Date Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ C I V I L \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 0 5 / 2 0 1 6 2 : 5 9 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 C3-1 GRADING PLAN.DWG C3.1 TWM TRG TWM 07-22-15 GRADING, DRAINAGE & EROSION CONTROL NOTES 1. ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 6 INCHES OF TOP SOIL AND SOD OR SEED. THESE AREAS SHALL BE WATERED BY THE CONTRACTOR UNTIL THE SOD OR SEED IS GROWING IN A HEALTHY MANNER. 2. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASE OF THIS PROJECT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGES TO ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASE OF THIS PROJECT. 3. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TRAFFIC CONTROL DEVICES SUCH AS BARRICADES, WARNING SIGNS, DIRECTIONAL SIGNS, FLAGMEN AND LIGHTS TO CONTROL THE MOVEMENT OF TRAFFIC WHERE NECESSARY. PLACEMENT OF THESE DEVICES SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE APPROPRIATE MINNESOTA DEPARTMENT OF TRANSPORTATION STANDARDS. 4. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 5. THE DUTY OF THE ENGINEER OR THE DEVELOPER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTORS SAFETY MEASURES IN, OR NEAR THE CONSTRUCTION SITE. 6. BEFORE BEGINNING CONSTRUCTION THE CONTRACTOR SHALL INSTALL A TEMPORARY ROCK ENTRANCE PAD AT ALL POINTS OF VEHICLE EXIT FROM THE PROJECT SITE. SAID ROCK ENTRANCE PAD SHALL BE MAINTAINED BY THE CONTRACTOR FOR THE DURATION OF THE PROJECT. 7. EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE ESTABLISHED AROUND THE ENTIRE SITE PERIMETER AND IN ACCORDANCE WITH NPDES PERMIT REQUIREMENTS, BEST MANAGEMENT PRACTICES, CITY REQUIREMENTS AND THE DETAILS SHOWN ON SHEET C8-1 OF THE PROJECT PLANS. 8. ALL ENTRANCES AND CONNECTIONS TO CITY STREETS SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND NOTIFICATIONS AS REQUIRED BY THE CITY. 9. SEE UTILITY PLANS FOR FURTHER DETAIL REGARDING THE STORM SEWER. 10. EACH LOT SHALL HAVE A BACK YARD SLOPE OF 10:1 OR FLATTER FOR A MINIMUM OF 20 FEET FROM THE BUILDING. 11. POWER POLE TO BE LOWERED BY OTHERS.  GENERAL NOTES SETBACKS: FRONT BUILDING SETBACK = 25' ZONING: EXISTING ZONING = RST-2 MULTIPLE FAMILEY RESIDENTIAL PROPOSED ZONING = PLANNED UNIT DEVELOPMENT SITE AREA: TOTAL AREA = ~17.7 AC TOTAL HOUSING UNITS = 45 NET DENSITY = 3.11 UNITS/ACRE IMPERVIOUS SURFACE AREA = 4.0 AC = 22.6% PERVIOUS SURFACE AREA = 13.7 AC = 77.4% WETLAND DATA: AREA OF EXISTING WETLANDS (ON PROPERTY): WETLAND 'A' = 14,262 SF WETLAND 'B' = 6,904 SF WETLAND 'C' = 3,628 SF WETLAND 'D' = 7,432 SF WETLAND 'E' = 1,982 SF WETLAND 'F' = 10,686 SF WETLAND 'G' = 16,974 SF WETLAND 'H' = 2,059 SF TOTAL AREA OF IMPACTED WETLAND = 11,984 SF WETLAND BUFFERS ARE BEING AVERAGED FOR WIDTH (SEE PLAN). PROPOSED WETLAND BUFFER TOTAL AREA - 83,381 SF (INCLUDES ALL PAVEMENT, ESTIMATED HOME AREA, AND ESTIMATED DRIVEWAY AREA) EXHIBIT C C0.1 C3.1 C3.2 C4.1 C4.2-C4.6 C5.1-C5.3 C8.1-C8.3 L1.1 L1.2 L1.3 COVER SHEET GRADING PLAN SWPP PLAN UTILITY PLAN STREET/STORM SEWER PLAN & PROFILES SAN. SEWER/WATER PLAN & PROFILES CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS TREE INVENTORY PLAN Todd W. McLouth - PE of the State of Minnesota. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws 20383 License No.Date Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ C I V I L \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 0 5 / 2 0 1 6 2 : 3 4 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 C4-1 UTILITY PLAN - FLIPPED.DWG C4-1 TWM TRG TWM 07-22-15  EX SAN MH SAN MH #1 SAN MH #2 CB #109 CBMH #108 SAN MH #3 CBMH #107 CB #110 SAN MH #4 SAN MH #5 SAN MH #6 CBMH #106 SAN MH #12 SAN MH #13 SAN MH #14 CBMH #105 FES #2 FES #4 FES #6 OCS #1 FES #5 FES #1 FES #7 CBMH #101 SAN MH #11 CBMH #102 SAN MH #8 SAN MH #9 STMH #103 SAN MH #10 CBMH #104 CB #113 CB #112 CBMH #111 FES #3 OCS #2 FES #9 FES #8 FES #11 FES #10 HYDRANT HYDRANT HYDRANT HYDRANT SAN MH #7 HYDRANT HYDRANT HYDRANT EXHIBIT D C0.1 C3.1 C3.2 C4.1 C4.2-C4.6 C5.1-C5.3 C8.1-C8.3 L1.1 L1.2 L1.3 COVER SHEET GRADING PLAN SWPP PLAN UTILITY PLAN STREET/STORM SEWER PLAN & PROFILES SAN. SEWER/WATER PLAN & PROFILES CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS TREE INVENTORY PLAN Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ L A N D S C A P E \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 0 5 / 2 0 1 6 3 : 6 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 L1-1 LANDSCAPE PLAN2436.DWG L1.1 TWM TJF DDL 02/13/15 PLANT SCHEDULE: GENERAL NOTES CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID. HE SHALL INSPECT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS RELATING TO THE NATURE AND SCOPE OF WORK. VERIFY LAYOUT AND ANY DIMENSIONS SHOWN AND BRING TO THE ATTENTION OF THE LANDSCAPE ARCHITECT ANY DISCREPANCIES WHICH MAY COMPROMISE THE DESIGN AND/OR INTENT OF THE PROJECT'S LAYOUT. ASSURE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS GOVERNING THE WORK OR MATERIALS SUPPLIED. CONTRACTOR SHALL PROTECT ALL EXISTING ROADS, CURBS/GUTTERS, TRAILS, TREES, LAWNS AND SITE ELEMENTS DURING PLANTING OPERATIONS. ANY DAMAGE TO SAME SHALL BE REPAIRED AT NO COST TO THE OWNER. CONTRACTOR SHALL VERIFY ALIGNMENT AND LOCATION OF ALL UNDERGROUND AND ABOVE GRADE UTILITIES AND PROVIDE THE NECESSARY PROTECTION FOR SAME BEFORE CONSTRUCTION / MATERIAL INSTALLATION BEGINS (MINIMUM 10' - 0" CLEARANCE). ALL UNDERGROUND UTILITIES SHALL BE LAID SO THAT TRENCHES DO NOT CUT THROUGH ROOT SYSTEMS OF ANY EXISTING TREES TO REMAIN. EXISTING CONTOURS, TRAILS, VEGETATION, CURB/GUTTER AND OTHER EXISTING ELEMENTS BASED UPON INFORMATION SUPPLIED TO LANDSCAPE ARCHITECT BY OTHERS. CONTRACTOR SHALL VERIFY ANY AND ALL DISCREPANCIES PRIOR TO CONSTRUCTION AND NOTIFY LANDSCAPE ARCHITECT OF SAME. THE ALIGNMENT AND GRADES OF THE PROPOSED WALKS, TRAILS AND/OR ROADWAYS ARE SUBJECT TO FIELD ADJUSTMENT REQUIRED TO CONFORM TO LOCALIZED TOPOGRAPHIC CONDITIONS AND TO MINIMIZE TREE REMOVAL AND GRADING. ANY CHANGE IN ALIGNMENT MUST BE APPROVED BY LANDSCAPE ARCHITECT. LANDSCAPE PLAN: TURF SEED MIX - MNDOT SEED MIX # 25-131. APPLY AT 220 LBS/AC. MID TERM STABILIZATION SEED MIX - MNDOT SEED MIX # 22-112. APPLY AT 40 LBS/AC. DRY PRAIRIE SEED MIX - MNDOT SEED MIX # 35-221. APPLY AT 36.5 LBS/AC. STORMWATER POND SEED MIX - MNDOT SEED MIX # 33-261. APPLY AT 35 LBS/AC. DRY POND SEED MIX - MNDOT SEED MIX # 33-262. APPLY AT 44 LBS/AC. SEEDING LEGEND: Date of the State of Minnesota. Douglas D. Loken, LA I am a duly Licensed Landscape Architect under the laws prepared by me or under my direct supervision and that I hereby certify that this plan, specification or report was 45591 License No. 02/10/15 EXHIBIT E C0.1 C3.1 C3.2 C4.1 C4.2-C4.6 C5.1-C5.3 C8.1-C8.3 L1.1 L1.2 L1.3 COVER SHEET GRADING PLAN SWPP PLAN UTILITY PLAN STREET/STORM SEWER PLAN & PROFILES SAN. SEWER/WATER PLAN & PROFILES CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS TREE INVENTORY PLAN Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ L A N D S C A P E \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 0 5 / 2 0 1 6 2 : 4 1 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 L1-1 LANDSCAPE PLAN2436.DWG L1.2 TWM TJF DDL 02/10/15 Date of the State of Minnesota. Douglas D. Loken, LA I am a duly Licensed Landscape Architect under the laws prepared by me or under my direct supervision and that I hereby certify that this plan, specification or report was 45591 License No. 02/10/15 LANDSCAPE INSTALLATION: COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING INSTALLATION WITH OTHER CONTRACTORS WORKING ON SITE. NO PLANTING WILL BE INSTALLED UNTIL COMPLETE GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA. WHERE SOD/SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SOD/SEED SHALL BE HELD 1" BELOW SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC. SEED ALL AREAS DISTURBED DUE TO GRADING OTHER THAN THOSE AREAS NOTED TO RECEIVE SOD. SEED SHALL BE INSTALLED AND MULCHED AS PER MNDOT SPECS. SOD SHALL BE LAID PARALLEL TO THE CONTOURS AND SHALL HAVE STAGGERED JOINTS. ON SLOPES STEEPER THAN 3:1 OR IN DRAINAGE SWALES, THE SOD SHALL BE STAKED TO THE GROUND. ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, DECIDUOUS SHRUBS SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED SHRUB HEIGHT. ORNAMENTAL TREES SHALL HAVE NO V CROTCHES AND SHALL BEGIN BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL. STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAN 6' ABOVE FINISHED GRADE. ANY CONIFEROUS TREE PREVIOUSLY PRUNED FOR CHRISTMAS TREE SALES SHALL NOT BE USED. ALL CONIFEROUS TREES SHALL BE FULL FORM, NATURAL TO THE SPECIES, WITHOUT PRUNING. PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN QUANTITIES EXIST. SPECIFICATIONS TAKE PRECEDENCE OVER NOTES. NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR. ADJUSTMENTS IN LOCATION OF PROPOSED PLANT MATERIALS MAY BE NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE ADVISED, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED. COORDINATE W/ OWNER FOR TIMING OF ALL TREE INSTALLATION. ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH DRIED BONE MEAL, OTHER APPROVED FERTILIZER MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS OR MAY BE TREATED FOR SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR 0-20-20 OF 12 OZ PER 2.5" CALIPER PER TREE AND 6 OZ PER SHRUB WITH AN ADDITIONAL APPLICATION OF 10-10-10 THE FOLLOWING SPRING IN THE TREE SAUCER. ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CALIPER THAN THE TREE BEING PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL WRAPPING AFTER 5-1. ALL TREES TO RECEIVE 4" DEEP SHREDDED HARDWOOD MULCH WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK. SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER MANUFACTURES RECOMMENDATIONS UNDER ALL MULCHED AREAS. THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE OWNER WITH A WATERING SCHEDULE APPROPRIATE TO THE PROJECT SITE CONDITIONS AND TO PLANT MATERIAL GROWTH REQUIREMENTS. IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT ESTABLISHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND/OR INSTALLATION. CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER ACCEPTANCE INSPECTION OF ALL LANDSCAPE AND SITE IMPROVEMENTS. CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL NEWLY INSTALLED MATERIALS UNTIL TIME OF OWNER ACCEPTANCE. ANY ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR PRIOR TO OWNER ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PROVIDE THE OWNER WITH A MAINTENANCE PROGRAM INCLUDING, BUT NOT NECESSARILY LIMITED TO, PRUNING, FERTILIZATION AND DISEASE/PEST CONTROL. CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE CALENDAR YEAR FROM THE DATE OF OWNER ACCEPTANCE. WARRANTY (ONE FULL GROWING SEASON) FOR LANDSCAPE MATERIALS SHALL BEGIN ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF PLANTING OF ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED. REPRODUCIBLE AS-BUILT DRAWING(S) OF ALL LANDSCAPE INSTALLATION AND SITE IMPROVEMENTS UPON COMPLETION OF CONSTRUCTION INSTALLATION AND PRIOR TO PROJECT ACCEPTANCE. UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT MATERIAL INSTALLATION AND SEED/SOD PLACEMENT IS FROM THE TIME GROUND HAS THAWED TO JUNE 15. CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND FALL DECIDUOUS PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. CONTRACTOR TO REFER TO TREE PRESERVATION PLAN FOR TREE REMOVALS. CONTRACTOR RESPONSIBLE FOR REGULAR WATERING OF INSTALLED PLANT MATERIAL. TYPICAL HOUSE FOUNDATION PLANTINGS: FOUNDATION PLANTINGS MUST CONSIST OF A COMBINATION OF DECIDUOUS AND CONIFEROUS SHRUBS AS WELL AS PERENNIALS. EACH HOME UNIT SHALL INCLUDE A MINIMUM 10 SHRUBS AND 10 PERENNIALS. PLANTINGS TO BE INSTALLED BY BUILDER AT TIME OF HOME CONSTRUCTION. OVERALL TREE DATA: TOTAL NUMBER OF TREES SURVEYED: 358 TREES TREE INFORMATION FOR TREE INVENTORY: L1.3 TWM DDL TWM 02/10/15 C0.1 C3.1 C3.2 C4.1 C4.2-C4.6 C5.1-C5.3 C8.1-C8.3 L1.1 L1.2 L1.3 COVER SHEET GRADING PLAN SWPP PLAN UTILITY PLAN STREET/STORM SEWER PLAN & PROFILES SAN. SEWER/WATER PLAN & PROFILES CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS TREE INVENTORY PLAN Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ L A N D S C A P E \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 0 5 / 2 0 1 6 3 : 3 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 L1-3 TREE INVENTORY.DWG TREE INVENTORY NOTES: THE EXISTING TREES SHOWN ON THIS PLAN WERE SURVEYED BY LOUCKS ASSOCIATES FROM 10/29/14 TO 11/05/14. SEE CHART ON SHEET L1.2 FOR TREE INFORMATION. NOT ALL TREES LISTED ARE ON THE PROJECT'S PROPERTY. SOME TREES LISTED ARE ON ADJACENT PROPERTIES. ALL TREES WITHIN THE CONSTRUCTION LIMITS WERE SURVEYED. TREES 50' BEYOND CONSTRUCTION LIMITS ON PROJECT PROPERTY WERE SURVEYED. ALL TREES WITHIN THE CONSTRUCTION LIMITS WERE SURVEYED. TREES 50' BEYOND CONSTRUCTION LIMITS ON PROJECT PROPERTY WERE SURVEYED. ALL TREES WITHIN THE CONSTRUCTION LIMITS WERE SURVEYED. TREES 50' BEYOND CONSTRUCTION LIMITS ON PROJECT PROPERTY WERE SURVEYED. 3800 TREE LEGEND: TREE TO REMAIN TREE TO BE REMOVED ALL TREES WITHIN THE CONSTRUCTION LIMITS WERE SURVEYED. TREES 50' BEYOND CONSTRUCTION LIMITS ON PROJECT PROPERTY WERE SURVEYED. 3800 Date of the State of Minnesota. Douglas D. Loken, LA I am a duly Licensed Landscape Architect under the laws prepared by me or under my direct supervision and that I hereby certify that this plan, specification or report was 45591 License No. 02/10/15 EXHIBIT F C2-2 TWM DDL TWM -- SITE PLAN GENERAL NOTES MINIMUM SETBACKS: BASE LOT = 30 FT, EXCEPT LOTS 1 AND 11, BLOCK 3 AS SHOWN ON SITE PLAN ZONING: EXISTING ZONING = PLANNED UNIT DEVELOPMENT SITE AREA: TOTAL AREA = ~17.7 AC TOTAL HOUSING UNITS = 45 NET DENSITY = 3.11 UNITS/ACRE IMPERVIOUS SURFACE AREA = 4.0 AC = 22.6% PERVIOUS SURFACE AREA = 13.7 AC = 77.4% ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER SHEET C8-1 AND THE REQUIREMENTS OF THE CITY. CURB AND GUTTER SHALL BE D412 PER CITY DETAIL. ALL INLET LOCATIONS SHALL BE B618 AT AS PER CITY DETAIL THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPT. AND THE CONSTRUCTION ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE STREET RIGHT OF WAY (SIDEWALK, STREET OR DRIVEWAYS) MINNESOTA STATE STATUTE REQUIRES NOTIFICATION PER "GOPHER STATE ONE CALL" PRIOR TO COMMENCING ANY GRADING, EXCAVATION OR UNDERGROUND WORK. APPROXIMATE LOCATION OF ON STREET PARKING STALL. (8'X22') TOTAL ON STREET PARKING STALLS - 87  WETLAND DATA: AREA OF EXISTING WETLANDS (ON PROPERTY): WETLAND 'A' = 12,808 SF WETLAND 'D' = 7,432 SF WETLAND 'E' = 1,982 SF WETLAND 'F' = 10,686 SF WETLAND 'G' = 16,974 SF WETLAND 'H' = 2,059 SF WETLAND BUFFERS ARE BEING AVERAGED FOR WIDTH (SEE PLAN). PROPOSED WETLAND BUFFER TOTAL AREA - 83,381 SF PROPOSED GRADING AND RESTORATION PLAN FOR THE WETLAND MITIGATION AREAS TO BE CORDINATED WITH THE CITY OF LAKEVILLE AND THE VERMILLION RIVER WMO. AREA OF UTILITY EASMENT - APPROX. 60,182 SF (INCLUDES ALL PAVEMENT, ESTIMATED HOME AREA, AND ESTIMATED DRIVEWAY AREA) SITE PLAN GENERAL NOTES .. Todd W. McLouth - PE of the State of Minnesota. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws 20383 License No.Date Sheet No.: Project No.: Sheet Title: Checked By:Review Date: Quality Control: Project Lead:Drawn By: Professional Signature: Submittal: Landscape Architecture Environmental Planning Civil Engineering Land Surveying for use solely with respect to this project. These CADD files are instruments of the Consultant professional services CADD files prepared by the Consultant for this project by the Consultant. With the Consultant's approval, others Consultant from any & all responsibilities, claims, and liabilities. deletions and that party shall hold harmless and indemnify the at the full risk of that party making such revisions, additions or revisions, additions, or deletions to these CADD files shall be made files for information and reference only. All intentional or unintentional may be permitted to obtain copies of the CADD drawing or for completion of this project by others without written approval shall not be used on other projects, for additions to this project, CADD Qualification: Professional Services: Project Name: W: \ 2 0 1 3 \ 1 3 5 8 5 \ C A D D D A T A \ C I V I L \ _ d w g S h e e t F i l e s \ 2 4 x 3 6 Pl o t t e d : 0 8 / 2 6 / 2 0 1 6 1 : 3 9 P M Sheet Index: Owner/Developer: 2016 7200 Hemlock Lane - Suite 300 Maple Grove, MN 55369 Telephone: (763) 424-5505 www.LoucksAssociates.com 525 15th Avenue South Hopkins, MN 55343 STREET = 25FT, EXCEPT LOTS 16-22, BLOCK 22 AT 20 FT PRIVATE DRIVE = 25 FT GUEST PARKING = 15 FT BETWEEN BUILDINGS = 10 FT EXHIBIT G