HomeMy WebLinkAbout150044 Energy Code Compliance Cert Date Certificate Posted
x Passive (No Fan)
Active (With fan and monometer or
other system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
X
R-10 X
R-21 X
R-21 X
R-21 X
R-49 X
R-30 X
R-30 X
R-30 X
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:80,000
Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%92%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
6"Passive
X Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
" round duct OR
" metal duct Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
43VP50E2 DX13SN036
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
R-410A
Make-up Air Select a Type
Rheem
Domestic Water
Heater
Gas
MECHANICAL SYSTEMS
Rating or Size
Efficiency 13SEER
/EER
Model
Heating System
Gas
Daikin
DM92SS0803B
Manufacturer Daikin
50 Output
in Tons:3
Appliances Cooling System
To
t
a
l
R
-
V
a
l
u
e
o
f
a
l
l
T
y
p
e
s
o
f
In
s
u
l
a
t
i
o
n
Type: Check All That Apply
Min
e
r
a
l
F
i
b
e
r
b
o
a
r
d
THERMAL ENVELOPE
Insulation Location
Fo
a
m
,
C
l
o
s
e
d
C
e
l
l
Fo
a
m
O
p
e
n
C
e
l
l
Wall
No
n
o
r
N
o
t
A
p
p
l
i
c
a
b
l
e
Fi
b
e
r
g
l
a
s
s
,
B
l
o
w
n
Fi
b
e
r
g
l
a
s
s
,
B
a
t
t
s
Foundation Wall
R-value
Average U-Factor (excludes skylights and one door) U:
Duct system air tightness:
Fuel Type
Solar Heat Gain Coefficient (SHGC):0.30
Describe other insulated areas
RADON CONTROL SYSTEM
Rim Joist (2nd Floor+)
0.30
Building envelope air tightness:
6 MIL POLY - 4" AGG
INTERIOR
INTERIOR
Below Entire Slab
Rig
i
d
,
E
x
t
r
u
d
e
d
P
o
l
y
s
t
y
r
e
n
e
Rig
i
d
,
I
s
o
c
y
n
u
r
a
t
e
Perimeter of Slab on Grade
Ceiling, flat
ATTIC
EXTERIOR
SEALANT
Rim Joist (1st Floor)
Windows & Doors
Ceiling, vaulted
66Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
150
Combustion Air Select a Type
Location of duct or system:
27,60056,147
Heating Gain Cooling Load
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
21,972
Residential Load
Calculation
Heating Loss
Bay Windows or cantilevered areas
Floors over unconditioned area
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.9/7/2016
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
Robert Thomas Homes
MN License Number
BC644819
City Mailing Address of the Dwelling or Dwelling Unit
Lakeville16315 Envoy Way
Builders Associaton of Minnesota version 101014