HomeMy WebLinkAboutSURVEYS 11x17 Zoning = RM-1 � +L� � ;"� �'�
FY - 20' House, 25' Garage '
SY - 7' Interior, 20' Corner , � e. ` �
RY - 30'
SY Buffer- 50' � � u � �
RY Buffer - 50' INCLI E WAY
- - - - - _--> _--->---__ -
�----->-
- --i-----�--S89°53'33"E 70.00
o ,�° 6h 6, h•-_--I-�"-� i. 6 0
"� ob - 06 0� .� c3� 06 �° -o`°��--I=
6�
r------g--- ----�---- ------- - ------r-�,� - ��---�-----
'.�1'� ,O6ro' ,060' \V'• � ,�;p6k. Op�`k `06�.
,� - " ._, ��q�' ', � � ;��6� � . .�Or°9' � - - -, � , O _ � _. � k. , _ -k. � -' _
- - �2_ 1 ,�� , ,p6�
- = ��ios�.o) � � � Y (�os4.-�) - -
� o o � � o � �g
� o o � a s.o� � a a
X o - - - -,� - - - - - � - � � a *Draintile connection required.
1067.54 �ri 5 r � �/� �� 5 c`nv g
1067.3 �
Benchmork N �� � M P N � tw= tos�.a
� � ° �Drrveway j � ; X Y � bw� �o5a.s 1063.74
; x I x � � x � �N � � g I Benchmark
�o�o.o) � n �o.os ioss.2 � x x `' X�o.o� �� ��os4.��
o � � --I-� � --- -- - �6�.$ T-f�-- X i� n io
2�.0� � ■ �v�j a afo
0 0 ; � `° 10.62 N � is.so � � : o
v �r i � j N,� a� $ g Porch � ■i I o p �
� 1071�5 f 'n G a r a e �,^ ^ �13.08 � ■ r �v
O � °'• � cv 9 �6.17No � �� tos5.o
�
� � � I N � o;/ o ■I '4 tob �
N x � ■ �
o J � ■ � M
� �'�, � g 10.1 �`0.12 ; x ■� x •
�, ------ ----- -----�
`�v, 7 oi 'O � � v I < N fo � i�-1 r o �� N
'X= `S - 00 I �� � o �ti � � ■I GO � .fn O7 r'-
�`' � I '� Proposed r� i � w=
� i � ^ i House ■�
I i M /8'4' F.�.W.O. ■�
r� I x N m/ a � n n
a � � I I �n ,"� X o � ■I a o .-. o
� o � � /! o "' ■ � � �
0 0 � � i X X o 39.75 0 0 ■� o �
^ � �- --�---L---� � - (-- o
(1065.0)o � 10�06 �� X�/ . ' tw= 1059.5 10�.07 � � (1056.2)
W �p�g�7 �,;%�,- �� f �� bw= s. o
'x;'
� Be c mark � � M � ^ I �� ; �` � " 1055.82
�1 0 ,� �' � � �� � (1059.5)0 � � o Benchmark w
� Graded � I � �I W I�� � r
p I � � I G aded (�
0 � � � (p
Z�� �� U�✓ � �i � �
1� x� x x x x x O
�� � .� x I M a � ao I e
�.` � O� I W N ri N N O
�� N � p I o� o � � o I � o -7 Z
� g o _�
.� 5 � I < � �
� � - � n
� � �
�� - - - �
� ` X X - -k _ _ x J 5
� � e - - - -
N� o � �o Drainage and x x
�x 'g a U}III{y + a N
__ eosement per plat � � o a
^ � o
� � X(1058•�)0 0 " �
�
=
w �.-. o o x a ��OS4.Z�o �
o vi o �n
x �, X o _ o
EROSION CONTROL o S86 L3�'I�"E � 70.�4 W x X
MUST BE INSTALLED ^ � � '°
BEFORE EXCAVATION � � '
0
n '
The curb box, drain tile cleanout and catch basin `fi ENGINEERING REVIEWED
(if applicable) must be inspected and accepted
before As-built escrow monies will be released. Date: 05/29/2019 mhughes
All structures must be flush with the sod. This ������� Denotes proposed retaining wall
will be scheduled with the landscape inspection. ee5�9�ed ond built by others.
OpOp�,�p Denotes boulder retaining wall
*Maintain 6�� between sidin gc SOd Lowest opening elevation per groding plon :1060.0
Lot orea = 8836 SF g � Denotes iron pipe
House areo = 1874 SF *No structures in easements �'� Lowest floor elevotion per groding plan : 1060.0
Denotes service
Porch area = 131 SF
�p Denotes television box
Sidewolk area = 21 SF � Denotes electric box House elevations Pro o ed
Driveway orea = 665 SF � A -buil
� Denotes telephone box Lowest Floor Elevation ; 1060.5
Totol Impervious Area = 2691 SF X 000.00 Denotes existing elevation ( � /
Impervious Coverage = 30.5 � Top Of Foundotion Elev. ;(�pg8.5) /
( 000.00 ) Denotes proposed elewtion
� Denotes drainage flow direction Garoge Slab Elev. � Door ;��Q6$,2� �
� Denotes spike �/
Construction Notes:
1. Install rock construction entrance. 0� 10' 20'
2. Install silt fence as needed for erosion control.
3. Sidewalks shall drain awoy from house a minimum of 1.0%.
4. Contractor must verify driveway design.
5. Contractor must verify service elevotion prior to
construction.
5cale: 1 = 20'
6. Add or remove foundation ledge as required.
General Notes: Benchmark:
1. Grading plan by Pioneer Engineering last dated 1-26-17 was used to We hereby certify to Lennar Corporation that this survey, plan or Top Nut Hydront
determine proposed elevations shown herein. Lots 7-8 Block 3
report was prepared by me or under my direct supervision, and Elevation = 1061.52
2. This survey does not purport to show improvements or encroachments, that I am a duly licensed Land Surveyor under the laws of the
except as shown, os surveyed by me or under my direct supervision. State of Minnesota, dated 04/17/19.
3. Proposed building dimensions shown are for horizontal location of structures
on the lot only. Contact builder prior to construction for approved construction Revisions:
plans. Signed: io eer En ineering, P.A.
I J 04-L9-19 Stake house
4. No specific soils investigation has been performed on this lot by the surveyor.
The suitability of soils to support the specific house proposed is not the
responsibility of the surveyor. BY�
5. This certificate does not purport to show easements other than those shown Pe er . ow inson, rofessiona Lon Surveyor
on the recorded plot. Minnesota License No. 42299 email-phawkinson�pioneereng.com
6. Bearings shown are based on an assumed datum.
PI�NEER �ot 6, Block 3,
�����P� SUMMERLYN 6TH ADDITION Certificate of Survey for:
CTVRENGINEERS LANDPLAM"CRS LAWSURVGY(MS LA\USC.iVLARCIRfCCTS
according to the recorded plat thereof Lennar Co oration
2422 Enterprise Drive Ph.:(651)681-1914 �d{COtd COUnty, Minnesota �
Mendota Heights,MN 55120 Fax:(651)681-9488 16305 36th Ave N Ste#600
www.pioneereng.com Address: 19157 Incline Way, Lakeville, Minnesota Plymouth,MN 55446-4270
House Model: Lewis Elevation: 63 Phone:(952)249-3000/Fax:(952)404-1909
Project#:117230023 Folder#:7999 Drawn by:KSO Buyer: Edlund