Loading...
HomeMy WebLinkAboutLA157686-Repair Requirements1973 12x46 – serial #:23687 This is a list of items noted at the preinstall inspection. All other deficiencies discovered at subsequent inspections, will also be required to be repaired before a certificate of occupancy is issued. - All gypsum board with any signs of mold or water damage must be replaced. - All exterior receptacles require weatherproof protective covers. - Smoke detectors required in each bedroom and one outside the bedrooms. Each bedroom also needs a CO alarm within 10’ of each bedroom. - The bottom belly lining is destroyed. The entire underside must be reinsulated and properly supported. - Any rotted wood on the underside of the trailer, including at the bottom of the exterior walls, must be replaced. - Each bedroom must have an egress window with a clear opening of 22” in width and height, and 5 square feet in area. The bottom sill must be within 48” of the floor. Verify existing windows meet this requirement or new windows will need to be installed. - The exterior of the home must comply with the City of Lakeville property maintenance code for peeling paint and all gaps sealed to prevent water intrusion.