HomeMy WebLinkAboutLA157686-Repair Requirements1973 12x46 – serial #:23687
This is a list of items noted at the preinstall inspection. All other deficiencies discovered at
subsequent inspections, will also be required to be repaired before a certificate of occupancy is
issued.
- All gypsum board with any signs of mold or water damage must be replaced.
- All exterior receptacles require weatherproof protective covers.
- Smoke detectors required in each bedroom and one outside the bedrooms. Each bedroom
also needs a CO alarm within 10’ of each bedroom.
- The bottom belly lining is destroyed. The entire underside must be reinsulated and properly
supported.
- Any rotted wood on the underside of the trailer, including at the bottom of the exterior walls,
must be replaced.
- Each bedroom must have an egress window with a clear opening of 22” in width and height,
and 5 square feet in area. The bottom sill must be within 48” of the floor. Verify existing
windows meet this requirement or new windows will need to be installed.
- The exterior of the home must comply with the City of Lakeville property maintenance code for
peeling paint and all gaps sealed to prevent water intrusion.