Loading...
HomeMy WebLinkAboutItem 06City of Lakeville Planning Department Memorandum To: Planning Commission From: Brent Jones, Planning Assistant/Code Enforcement Technician Date: August 10, 2018 Subject: Packet Material for the August 16, 2018 Planning Commission Meeting Agenda Item: Northland Collision Conditional Use Permit Amendment Application Action Deadline: September 14, 2018 INTRODUCTION Representatives of Northland Collision are requesting a conditional use permit amendment to allow an expansion to the building on the property located at 7430 160th Street. The proposed addition will include a 3,420 square foot expansion to the south side of the existing building. The proposed building expansion requires an amendment to Conditional Use Permit No. 99- 01, which established the automobile repair use and allowed an expansion to the building that was previously a car wash. The subject property is zoned C-3, General Commercial District. Section 11-73-7B of the Zoning Ordinance allows major automobile repair on properties in the C-3 District by conditional use permit. EXHIBITS A. Location Map B. Site Plan C. Building Elevations D. Floor Plan E. CUP 99-01 (3 pages) Surrounding Land Uses and Zoning North – 160th Street (CSAH 46) South – Toll Gas & Welding, Apple Lake Animal Hospital (C-3) East – Glacier Avenue and Pro-Tech Automotive (C-3) West – Dakota Plaza Commercial Building (C-3) 2 PLANNING ANALYSIS The applicant proposes a 3,420 square foot expansion to the south side of the existing 4,946 square foot building over an existing paved area. The building expansion will be used for major auto repair including auto body repair. The proposed expansion was reviewed for conformance with the Zoning Ordinance performance standards as follows: Building Setbacks. The existing building meets the additional setback requirements for major auto repair in the C-3 District of: Front – 30 feet Side – 20 feet Side abutting street – 30 feet Rear – 30 feet The proposed building addition will have the following setbacks: Front – 55 feet Side – 21 feet Side abutting street – 91 feet Rear – 70 feet Building Height. The new addition will match the height of the existing building as a 21 foot single story building and will not exceed the maximum building height of 35 feet allowed in the C-3 District. Floor Plan. The floor plan for the addition will include a 3,420 square foot auto body shop. Access and Circulation. The property access will remain unaffected by the proposed addition. The site is accessed via one driveway from Glacier Avenue. Parking. The site currently has 19 parking spaces on the east side of the property. The proposed site plan shows proof of parking for an additional 18 spaces on the south side of the property. The Zoning Ordinance requires 1 parking space per 200 square feet of floor area for auto repair uses established after March 17, 2003. Since this use was established in 1999, it would follow the old requirement of 8 spaces plus one space per 800 square feet of building area in excess of 1,000 square feet. The total building size with the addition is 8,366 square feet. The required parking is calculated as follows: 8,366 – 10% = 7,529.4 – 1000 = 6,529.4 / 800 = 8 + 8 = 16 parking spaces required There are 19 spaces on the property with space for up to 18 additional spaces for a total of 37 parking spaces, which is in compliance with Zoning Ordinance requirements. If the new requirements were to be applied, the required parking calculations would be as follows: 8,366 – 10% = 7,529.4 / 200 = 38 parking spaces required 3 Building Elevations and Exterior Building Materials. The existing building consists of painted concrete block and masonry. The proposed addition will consist of matching concrete block and accents in compliance with Zoning Ordinance requirements. Signs. The Zoning Ordinance allows one wall sign on two separate elevations for a property with two street frontages. Northland Collision currently has one wall sign on the north elevation, one wall sign on the west elevation, and one freestanding sign. All signs are in compliance with Zoning Ordinance requirements and no additional signage is being proposed. Lighting. The lighting shown on the building elevation plan is downcast design only, as required by the Zoning Ordinance, and will require the approval of an electrical permit prior to installation. Landscaping. Section 11-73-7B.2 requires that at least 25% of the property remain as landscaped green area. Approximately 50% of the property will remain landscaped in compliance with Zoning Ordinance requirements. There are numerous trees and shrubs on the property that will not be impacted by the expansion. RECOMMENDATION Planning Department staff recommends approval of the Northland Collision conditional use permit amendment subject to the following stipulations: 1. The stipulations of the conditional use permit dated March 1, 1999 (CUP 99-01) shall remain in full force and effect. Findings of fact are attached. Northland Collision CUP Property Information Au gust 8, 2018 0 225 450112.5 ft 0 60 12030 m 1:2,400 Disclaimer: Map and parcel data are believed to be accurate, but accuracy is not guaranteed. This is not a legal document and should not be substituted for a title search,appraisal, survey, or for zoning verification. COUNTY ROAD NO. 46 (160TH STREET WEST)GLACIER AVENUEEXISTING BUILDING EXISTING BUILDING NEW 1-STORY ADDITION (3,420 SF)DRAINAGE & UTILITYEASEMENT PER PLAT100'- 0" N O R T H E R N N A T U R A L G A S C O M P A N Y E A S E M E N T A S S H O W N O N P L A T EXISTING TRASH ENCLOSURE PROPERTY LINE PROPERTY LINE ℄ EXISTING BUILDING EXISTING BUILDING EXISTING TRANSFORMER AND PAD EXISTING SIGN DEMO EXISTING CURB EXISTING PAVEMENT EXISTING PAVEMENT EXISTING CURB CUT 18 9 10 DEMO EXISTING CURB FOR NEW PARKING STALLS Fax: (952) 854-3126 www.encompassinc.com engineering consultants forensic analysis Tel: (952) 854-4511 CONSULTANTS: CERTIFICATION: Registration Number Date Signature Name Project Number: Date: Drawn: Checked: Scale: REVISIONS: PROJECT: SHEET TITLE: SHEET NUMBER: I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. 6583 05/18/2018 OV AS NOTED 2018 BUILDING ADDITION NORTHLAND COLLISION 7430 160TH STREET WEST LAKEVILLE, MN 55068 - 5435 Feltl Road Minnetonka, MN 55343 SITE PLAN A2SITE PLAN1 A2 SCALE: 1/16" = 1'-0" TRUE NORTH 21 3 41.3 1.6 MATCH EXISTG. FIELD VERIFY ACCENT BAND TO MATCH EXISTING BLOCK TEXTURE, PAINT COLOR, & LOCATION T.O. PARAPET 21'-0" T.O. SLAB EL. 0'-0" A.2 AEBCDB.9 2'-0"2'-0" 6'-0" 2'-0" MATCH EXISTG. FIELD VERIFY T.O. PARAPET 21'-0" T.O. SLAB EL. 0'-0" NORTHLAND COLLISION MATCH EXISTG. FIELD VERIFY A B C D E 4'-0" 2'-0" 6'-0" 2'-0" 6'-0" 2'-0" 6'-0" 2'-0" 6'-0" 2'-0" 6'-0" 2'-0" 4'-0" NEW SCUPPER IN EXISTING WALL, MATCH EXISTING MEMBRANE ELEVATION. PATCH EXISTING MEMBRANE, SEE 3/A7 REMOVE EXISTING SCUPPER, INFILL OPENING, PATCH EXISTING ROOF MEMBRANE, SEE 3/A8 T.O. PARAPET 21'-0" T.O. SLAB EL. 0'-0" FIELD VERIFY, TYP. T.O. PARAPET 13'-8" COLLISION NORT H AND L 2 1341.31.6 MATCH EXISTG. FIELD VERIFY T.O. PARAPET 21'-0" T.O. SLAB EL. 0'-0" FIELD VERIFY, TYP. T.O. PARAPET 13'-8" Fax: (952) 854-3126 www.encompassinc.com engineering consultants forensic analysis Tel: (952) 854-4511 CONSULTANTS: CERTIFICATION: Registration Number Date Signature Name Project Number: Date: Drawn: Checked: Scale: REVISIONS: PROJECT: SHEET TITLE: SHEET NUMBER: I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. 6583 05/18/2018 OV AS NOTED 2018 BUILDING ADDITION NORTHLAND COLLISION 7430 160TH STREET WEST LAKEVILLE, MN 55068 - 5435 Feltl Road Minnetonka, MN 55343 ELEVATIONS A6 WEST ELEVATION3 A6 SCALE: 1/8" = 1'-0" EAST ELEVATION4 A6 SCALE: 1/8" = 1'-0" SOUTH ELEVATION2 A6 SCALE: 1/8" = 1'-0" NORTH ELEVATION1 A6 SCALE: 1/8" = 1'-0" SIM @ LOWER ROOF EDGE ACCENT BAND TO MATCH EXISTING BLOCK TEXTURE, PAINT COLOR, & LOCATION LIGHT FIXTURES BY OTHERS, TYP EXISTING LIGHT FIXTURES TO REMAIN LIGHT FIXTURES BY OTHERS, TYP WINDOWS TYP. SEE DETAILS 8/A8 THROUGH 10/A8 WINDOWS TYP. SEE DETAILS 8/A8 THROUGH 10/A8 SCUPPER & DOWNSPOUT CJ CJ CJ CJ 21 3 4 A B C D E 2.221 A.2 A E 3 4 B C D B.9 1.3 1.6 UP2'-0"2'-0"69'-8" 10'-0" 132'-5" 10'-0"28'-0"50'-0"6'-4"26'-0"32'-0"4'-0"28'-0"68'-5"64'-0" 132'-5" 31'-9"32'-3" 62'-9"3'-0"82'-0"50'-0"24'-0"2'-8" 10'-0" 2'-8"14'-0"11'-0"EXISTING SHOP AREA - 1 (N.I.C.) NEW MECH., BY OTHERS NEW MECH. UNITS, BY OTHERS PAINT BOOTH 101 100-A 100-B 100-C 100-D100-ENEW PRE-FAB PAINT BOOTH ENCLOSURE BY OTHERS NEW PIT, SEE STRUCT. DWGS SHOP AREA - 3 100 O.H. DOOR ON OPEN POSITION, TYP. SEE SHT. A6 FOR CLEARSTORY WINDOWS FD FD FD NEW 3'-7" x 7'-0" x 4 1/2"D LIFT PIT. VERIFY NUMBER, SIZE, & LOCATION WITH OWNER PRIOR TO CONSTRUCTION, SEE STRUCT. DWGS FD FD INFILL EXISTING PIT, SEE STRUCT. DWGS, TYP EXISTING SHOP AREA - 2 101 10"FIELD VERIFY20'-5" FIELD VERIFY 28'-8" FIELD VERIFY 19'-4" FIELD VERIFY 100-FSEE SHEET A6 FOR CLEARSTORY WINDOWS SPLASH BLOCK SPLASH BLOCK 6"6" TRENCH DRAIN SLOPE TO DRAIN Fax: (952) 854-3126 www.encompassinc.com engineering consultants forensic analysis Tel: (952) 854-4511 CONSULTANTS: CERTIFICATION: Registration Number Date Signature Name Project Number: Date: Drawn: Checked: Scale: REVISIONS: PROJECT: SHEET TITLE: SHEET NUMBER: I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. 6583 05/18/2018 OV AS NOTED 2018 BUILDING ADDITION NORTHLAND COLLISION 7430 160TH STREET WEST LAKEVILLE, MN 55068 - 5435 Feltl Road Minnetonka, MN 55343 FLOOR PLAN A3 FLOOR PLAN1 A3 SCALE: 1/8" = 1'-0" TRUE NORTH 1.ELECTRICAL REQUIREMENTS TO BE COORDINATED BY OWNER/CONTRACTOR/ELECTRICAL, TYP. GENERAL NOTES 1 CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA NORTHLAND COLLISION CONDITIONAL USE PERMIT AMENDMENT FINDINGS OF FACT AND RECOMMENDATION On August 16, 2018 the Lakeville Planning Commission met at its regularly scheduled meeting to consider the application of Northland Collision for a conditional use permit amendment to allow an expansion to the existing major automobile repair building located at 7430 160th Street in the C-3 District. The Planning Commission conducted a public hearing on the proposed conditional use permit amendment preceded by published and mailed notice. The applicant was present and the Planning Commission heard testimony from all interested persons wishing to speak. FINDINGS OF FACT 1. The property is located in Planning District No. 3 of the 2008 Comprehensive Plan, which guides the property for commercial uses. 2. The property is currently zoned C-3, General Commercial District. 3. The legal description of the property is: Lot 2, Block 1, Dakota Plaza 4. Section 11-4-3E of the City of Lakeville Zoning Ordinance provides that a conditional use permit may not be issued unless certain criteria are satisfied. The criteria and our findings regarding them are: a. The proposed action has been considered in relation to the specific policies and provisions of and has been found to be consistent with the official City Comprehensive Plan. Finding: The proposed use is a commercial use consistent with the policies and provisions of Planning District 8 of the 2008 Comprehensive Land Use Plan. b. The proposed use is or will be compatible with present and future land uses of the area. Finding: The proposed expansion will be compatible with existing and future land uses in the area. 2 c. The proposed use conforms with all performance standards contained in the Zoning Ordinance. Finding: The proposed expansion will conform with all performance standards contained in the Zoning Ordinance and the City Code. d. The proposed use can be accommodated with existing public services and will not overburden the City’s service capacity. Finding: The subject property is served with existing public services and will not overburden the City’s service capacity. e. Traffic generation by the proposed use is within capabilities of streets serving the property. Finding: Traffic generation will not significantly increase due to the proposed expansion to the major auto repair use. 5. The planning report dated August 10, 2018 prepared by Brent Jones, Planning Assistant/Code Enforcement Technician is incorporated herein. RECOMMENDATION The Planning Commission recommends that the City Council approve the conditional use permit amendment. DATED: August 16, 2018 LAKEVILLE PLANNING COMMISSION BY: _______________________________ Pat Kaluza, Chair