Loading...
HomeMy WebLinkAboutLA163405 - 19491 Iteri Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 3 :1 5 P M 00 T i t l e S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N t h e P e r r o n R e s i d e n c e LAKEVILLE, MN Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 08/01/2018dmathews First Floor 0' - 0" Second Floor 11' - 7 7/8" Roof 19' - 9" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Basement Clg. - 1' - 6 3/4" L o w e r L e v e l W i n d o w H e i g h t 7 ' - 0 " U p p e r L e v e l W i n d o w H e i g h t 7 ' - 0 " M a i n L e v e l W i n d o w H e i g h t 8 ' - 0 " 1 2 ' - 3 7 /8 " 8 ' - 1 1 /8 " 1 ' - 6 3 /4 " 1 0 ' - 1 1 /8 " 1 ' - 8 1 /4 " 9 ' - 0 " 5/4" x 12" TRIM 5/4"x6" TRIM 5/4" x 8" TRIM 4/4" x 18" SKIRT BOARD C C D B CUSTOM CHIMNEY SHROUD 8:12 SLOPE METAL SEAM ROOF 6:12 SLOPE METAL SEAM ROOF 5/4" x 6" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5 /4 " x 4 " T R I M 5 /4 " x 4 " T R I M 12" SOFFIT WITH 5" CROWN 5 /4 " x 8 " F R I E Z E B O A R D 2 - 1/4" STONE CAP 5 /4 " x 8 " F R I E Z E B O A R D 8:12 SLOPE METAL SEAM ROOF 120" 76" 5/4" x 10" TRIM WITH 2"x2" TRIM E E 5/4" x 10" TRIM WITH 2"x2" TRIM 132" 6 09 BRACKET #1 6 09 BRACKET #1 5/4" x 8" TRIM 5/4" x 8" TRIM 12" SOFFIT WITH 5" CROWN 4/5 02 CUSTOM FLOWERBOXS w/ CORBELS 5/4" x 8" TRIM B B A A A A A A A 3030 FX @ 13'- 6" FROM U.L. BRACKET #1 6 09 BRACKET #1 6 09 Roof Peak 32' - 0 211/256" 29 1/2" 5 /4 " x 8 " F R I E Z E B O A R D 5/4" x 6" TRIM 4/4" x 12" SKIRT BOARD 5/4" x 12" TRIM B CUSTOM CHIMNEY SHROUD 5/4"x12" TRIM A A A A B 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4"x12" TRIM 5/4"x12" TRIM 5/4"x12" TRIM B E A A A A 5/4" x 10" TRIM WITH 2"x2" TRIM NOTE: PROPOSED RETAINING WALL VERIFY WITH SITE SURVEY AND LANDSCAPE DESIGNER CXW245 w/ SDL TO APPEAR AS A DH WINDOW. 29 1/2" 1 1/2" 1 1/2" 1 1 /2 " 1 1 /2 " 2 5 1 /4 " 5/4" x 6" TRIM 5/4" x8 " TRIM 5 /4 " x 6 " T R I M 5 /4 " x 6 " T R I M 5 /4 " x 6 " T R I M 5 /4 " x 6 " T R I M C O M P O S I T E P A N E L C O M P O S I T E P A N E L 26 3/8" 7 8 " 5 1 /2 " 1 2 1 /2 " 7 1 /4 " ASPHALT ROOF 4 - 1/2": 12" SLOPE 12" SOFFIT w/ 5" CROWN 1 1 1 /4 " D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 3 :3 9 P M 01 F r o n t & R e a r E l e v a t i o n s S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N TYPICAL EXTERIOR MATERIALS SQ FT BREAKDOWN SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE 7" EXPOSURE HARDIELAP SIDING PER ELEVATION 7" EXPOSURE HARDIESHAKE STRAIGHT PER ELEVATION 2" STONE VENEER PER ELEVATION HARDIEPANEL SMOOTH PER ELEVATION HARDIE BOARD AND BATTEN SMOOTH @ 16" O.C. INSTALL KICK OUT FLASHING & TWO MEMBRANE TAR PAPER BACKING IN ALL STONE AREAS 5/4" x 6" HARDIE WINDOW & DOOR WRAPS PER ELEVATION 5/4" x 6" HARDIE CORNER BOARDS PER ELEVATION METAL SEAMED ROOF PER ELEVATION 1X3 ON 1X8 METAL FASCIA PER ELEVATION ALUMINIUM VENTED SOFFITS PER ELEVATION EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR B C D A 1/4" = 1'- 0" 1 Front Elevation 1/4" = 1'- 0" 2 Rear Elevation 1/2" = 1'- 0" 3 Detail - Front Elevation - Office Bump Out E 5/4" x 12" TRIM 4/4" x 12" SKIRT BOARD CUSTOM CHIMNEY SHROUD A A A B C D 5/4"x12" TRIM 5/4"x6" TRIM SOFFIT w/ 5" CROWN 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" F R IE Z E B O A R D 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 8" F R IE Z E B O A R D 5/4" x 6" TRIM 5/4" x 8" TRIM S t o n e C a p 2 1 /4 " 5/4" x 6" TRIM 5 /4 " x 8 " F R I E Z E B O A R D A A B A A D A NOTE: PROPOSED RETAINING WALL VERIFY WITH SITE SURVEY AND LANDSCAPE DESIGNER 72" 4/4" x 18" SKIRT BOARD 5/4" x 8" TRIM A A A A C 5/4"x12" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5/4" x 8" TRIM 5 /4 " x 6 " F R Z . B R D 5/4" x 8" F R IE Z E B O A R D 5/4" x 8" F R IE Z E B O A R D 5 /4 " x 8 " F R I E Z E B O A R D 5/4" x 8" TRIM 5 /4 " x 4 " T R I M 5 /4 " x 4 " T R I M 5/4" x 8" FRIEZE BOARD A TWT 2423 @ 19'- 6" FROM T.O.F. A 5/4" x 8" TRIM BOARD A 5/4" x 6" TRIM SOFFIT w/ 5" CROWN B 5/4"x12" TRIM TWT 2423 @ 11'- 0" FROM U.L. 8:12 SLOPE 76" 2 4 " 18" 132" 6" ENGINEERING ROOF TRUSSES PER MFG. SPEC. MANUFACTURE WILL PROVIDE ALL ENGINEERING DRAWING AND SPECIFICS OVERHANG DIMENSIONS ARE TO FACE OF FRAMING ICE AND WATER ALL ADJOINING ROOFS NOTE: RIDGE VENT RIDGE VENT 18" / 12" 5 " / 1 2 " 6 " / 1 2 " 1 4 " / 1 2 " 1 4 " / 1 2 " 4 " / 1 2 " 6 " / 1 2 " 1 4 " / 1 2 " 1 4 " / 1 2 " 1 4 " / 1 2 " 1 4 " / 1 2 " 1 4 " / 1 2 " METAL SEAM ROOF 6:12 SLOPE 2 4 " 18" 1 2 " 1 4 " / 1 2 " 8 " / 1 2 " 18" / 12" 18" / 12" 18" / 12" 18" / 12" 6 " / 1 2 " 18" / 12" 1 4 " / 1 2 " 8:12 SLOPE 120" 4 1 /2 " / 1 2 " 1 1 4 " 4 2 " 1 8 " 12" 24" 1 8 " 1 2 " 16" 3 0 " 3 0 " 12" 88" 1 8 " 2 4 " 12" 1 2 " 6" 6" 1 8 " 18" 1 8 " 1 8 " 18" 1 2 " 12" 1 2 " 18" 2 4 " 8 " / 1 2 "4 " / 1 2 " 1 8 " 1 5 " 1 1 /2 " 1 1 /2 " 5 1/2" 5 1/2" EQ. 16 3/4" 2 " 2 " 3 1/2" 3 1/2" Finish Box 44" Finish Trim 47" 1 8 " Framing 12" 5 1 /2 " 5 1/2" 2 3 1 /2 " Finish To Trim 14 1/4" 1 1/2" 1 1 /2 " 1 5 " 1 1 /2 " VENTED 3/4" PANEL METAL PAN INSERT 2x2 TRIM 3/4" PANEL 2x2 TRIM 2x4 FRAMING 6x6 CORBEL w/ 3" RAD. PORCH COLUMN CONSTRUCTION: 2X8 TOP/BOTTOM COLLAR 3/4" COMPOSITE WRAP 1/2" PLYWOOD 2X4 FRAMED BOX 6x6 TRD. STRUCTURAL POST PER MFG. SPEC. PORCH COLUMN SUPPORTING STEEL BEAMS CONSTRUCTION: 2x8 TOP/BOTTOM COLLAR 3/4" COMPOSITE WRAP 1/2" PLYWOOD 2X4 FRAMED BOX 6x6 TRD. STRUCTURAL POST PER MFG. SPEC. STEEL BEAM DROPPED PER MFG. SPEC. 6 X 6 T R D S T R U C T U R A L P O S T 6 x 6 T R D S T R U C T U R A L P O S T 7 1 /4 " 8 8 3 /4 " 7 1 /4 "Framing 13 1/2" Framing 13 1/2" F r a m i n g 1 3 1 /2 " PORCH COLUMN CONSTRUCTION: 2X8 TOP/BOTTOM COLLAR 3/4" COMPOSITE WRAP 1/2" PLYWOOD 2X4 FRAMED BOX 6X6 TRD STRUCTURAL POST PER MFG. SPEC. F i n i s h e d 1 6 " Finished 16" D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :0 3 P M 02 L e f t & R i g h t E l e v a t i o n s S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N 1/4" = 1'- 0" 1 Left Elevation 1/4" = 1'- 0" 2 Right Elevation 1/8" = 1'- 0" 3 Roof Plan 1" = 1'- 0" 4 Detail - Flowerbox (Front View) 1" = 1'- 0" 5 Detail - Flower Box (Cross Section) 3/8" = 1'- 0" 6 Detail - Front Porch Column 1 1/2" = 1'- 0" 7 Detail - Front Porch Column (Plan View) UP 8" 8 " 8" 8 " 8 " 8" 8" 8 " 8 " 8" 8 " 10" 8" 8 " 4 6 " 7 0 " 8 " 8 " 8 " 8" MAIN FND WALL: 9'- 0"x8" POURED CONC. FOUNDATION ON 20"X8" CONCRETE FOOTING REBAR PER CODE DECK / PORCH FOOTINGS: 10"x10" COMPOSITE WRAPPED COLUMNS ON 18" SONO TUBE @ 42" BELOW GRADE INTERIOR THERMAL WALL: (UNEXPOSED WALLS ONLY) 1" AIRSPACE 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. SIMPSON METAL TIES: END JOISTS TO BEAM - LUC21OZ POST TO FOOTING - ABW66Z POST TO BEAM - LPC6Z MIDDLE JOISTS - LUS21OZ DECK RIM TO HOUSE - 3/8"x5 - 1/2" COATED LAG BOLTS & WASHERS DIMENSIONS ARE TO EDGE OF CONCRETE AND EDGE OF FRAMING FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C. FLOOR SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 8'- 10" UNLESS NOTED SET WINDOW HDRS @ 84" FROM CONCRETE FLOOR UNLESS NOTED NOTE: WATER & SEWER SLEEVES A.C. PAD G A S & E L E C T R I C S E R V I C E L O C A T I O N DIMENSIONS DO NOT REFLECT FOUNDATION BEING PULLED IN BY 1 1/2" OR THE SILL PLATE BEING CANTILEVERED. REFER TO SILL PLATE DETAIL (PG 03) AND THE ENGINEERED STRUCTURAL DRAWINGS FROM A LICENSED STRUCTURAL ENGINEER. NOTE: FAN INTERIOR THERMAL WALL: (EXPOSED WALLS ONLY) 1" RIGID INSULATION (R - 5) 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. PORCH FND WALL: 3'- 6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE WALK OUT WALL: 2X6 STUDS @ 16" O.C. 5'- 0"x10" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE PROVIDE 3 1/2"x5 1/2" POUR ON TOP OF 10" WALL UNDER 2X6 WALL FD WATER HEATER F U R N A N C E 48" VANITY 3 4 "x 6 0 " F B R G L S S H O W E R MECH. ROOM CONCRETE OSB WALLS - UNEXCAVATED - 2) 36"x36"x12" CONC. PAD (TYPICAL) 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 x 1 0 J O I S T S @ 1 6 " O .C . SUMP w/ SEALED COVER 2" SLAB LEDGE 2X6 BRNG W.O. SMOKE DET. NOTE: SOLID BLOCK ALL JOIST SPACES FIRE CAULK ALL PENETRATIONS IN SOLID BLOCK 1) 32"x80" DOOR S I L C O C K BEAM PER MFG. SPEC FLUSH 54" x 96" OP'NG B.P.M.S.D. BATH LVT FLOOR 1 ) 2 8 "x 8 0 " D O O R guest BEDROOM CARPET FLOOR W E T B A R L V T F L O O R FAMILY ROOM CARPET FLOOR S N K U P P E R S 1 2 " O V E R H A N G GAME ROOM CARPET FLOOR STAIRS EXTERIOR THERMAL WALL: 2" RIGID INSULATION SYSTEM (R - 10) APPLIED TO EXTERIOR PROVIDE FLASHING 17'- 0"x8'- 0" C.O. BEAM DROPPED PER MFG. SPEC. SET B.O. HDR HGT. @ 96" UNDER STAIR ST'RG GARAGE FND WALL: 3'- 6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL NOTE: PROPOSED RETAINING WALL, VERIFY LOCATION AND DESIGN WITH LANDSCAPE DESIGNER AND SURVEYING ENGINEER 11' - 9 1/4" 18' - 5 1/2" 4' - 9 1/4" 4' - 9 1/4" 7' - 4 3/4" 1 ' - 1 0 3 /4 " 5 ' - 4 1 /2 " 6 ' - 1 1 1 /2 " 1 5 ' - 9 1 /4 " 7' - 3 3/4" 3' - 9 1/2" 5' - 7 1/2" 13' - 11 1/4" 3 ' - 5 1 /4 " 6 ' - 1 1 1 /2 " 1 5 ' - 8 3 /4 " 1 8 ' - 0 1 /2 " 1 0 ' - 7 " 1 3 ' - 7 1 /2 " 1 ' - 8 3 /4 " 1 8 ' - 2 3 /4 " 7 7 " 5 0 " 51 3/4" 4 1/2" 51 3/4" 46 3/4" 11' - 6 1/2" 18' - 11" 9' - 6 1/2" 6' - 6" 29' - 6" 76' - 0" 6' - 3 1/2" 5' - 3" 9' - 5 1/2" 9' - 5 1/2" 5' - 0" 5 4 ' - 6 " 1 6 ' - 0 1 /2 " 2 8 ' - 0 " 6 ' - 0 " 3 0 " 2 3 1 /2 " 76' - 0" 30' - 0" 18' - 0" 4' - 0" 24' - 0" 5 4 ' - 6 " 6 ' - 6 " 3 0 ' - 0 " 1 8 ' - 0 " 2 ' - 6 " 7 ' - 2 " 6" 3' - 10 1/2" M.O. 16' - 3" 3' - 10 1/2" 3 ' - 6 1 /4 " M .O . 9 ' - 0 " 3 ' - 6 1 /4 " 1 0 " 2X10 BEARING WALL 1 0 " LINEN - UNEXCAVATED - - UNEXCAVATED - 2 X 6 W A L L 2 X 6 B R G W A L L WOOD FLOOR w/CARPET RUNNER 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 " S L A B L E D G E 2" SLAB LEDGE 2 " S L A B L E D G E 2" SLAB LEDGE 2 " S L A B L E D G E 2 " S L A B L E D G E 2 " P O R C H L E D G E2" PORCH LEDGE CONCRETE storage CONCRETE FLOOR B E A M P E R M F G . S P E C F L U S H BEAM PER MFG. SPEC FLUSH BEAM PER MFG. SPEC FLUSH 6 ' - 6 " 1 4 ' - 0 " 1 6 ' - 0 " 1 2 ' - 0 " 6 ' - 0 " DECK ABOVE 25' - 6 1/2" 8' - 0" 6' - 0" 2 X 6 B R G W A L L W.O. W.O. W.O. 1 ) 3 0 "x 8 0 " D O O R 1 ) 2 8 "x 8 0 " D O O R 1 ) 3 0 "x 8 0 " D O O R 1) 36"x80" DOOR R A D O N P I P E 9 '-0 " P O U R E D W A L L 6 ' - 0 " 4 ' - 0 " 8 ' - 0 " 16' - 6" 2 7 ' - 6 1 /2 " 1 7 ' - 9 1 /2 " 1 4 ' - 3 " 1 ' - 7 3 /4 " 1 ' - 7 " 4 ' - 8 3 /4 " INTERIOR BEARING WALLS: 4X6 TREATED WOOD 16"X8" FOOTING (TYPICAL) 8 '- 0 " I S L A N D 9' - 0" 1 5 ' - 2 " 1 1 ' - 0 1 /2 " 4 09 1 06 3 07 2 06 3 06 1 07 5 08 4 06 3) 36"x36"x12" CONC. PAD (TYPICAL) POINTS TO BEAR FROM ABOVE ON BEAM 36"x36"x12" CONC. PAD (TYPICAL) 4' - 5 1/2" 2" PORCH LEDGE 2 " P O R C H L E D G E 2' - 0" 4' - 0" 16' - 0" 2' - 0" 6' - 0" 2' - 0" 4' - 0" BEAM FLUSH PER MFG .SPEC. 1 )3 0 "x 8 0 " D O O R R&S W.I.C. CARPET FLOOR B E A M P E R M F G . S P E C F L U S H HANG DECK JOISTS OFF PORCH TRUSSES AT THIS LOCATION Post to Post 14' - 0" Post to Framing 11' - 6 1/2" 3 08 3" 1 6 " 16" 48" 9 2 " 8 " 1 6 " 16" 88" 16" 1 6 " 3" 2 08 2 04 I N T E R I O R B E A R I N G W A L L S : 4 X 6 T R E A T E D W O O D 1 6 "X 8 " F O O T I N G (T Y P I C A L ) 6 08 PORCH COLUMN FOOTINGS: 24"x24"x42" POURED CONCRETE PIER 36"x36"x8" FOOTING REBARD PER CODE 16" 1 6 " 2 ' - 0 " 1 6 ' - 6 " 2 ' - 0 " 4 08 2) TW210410 BEAM PER MFG. SPEC. TW34510 BEAM PER MFG. SPEC. TW34510 BEAM PER MFG. SPEC. 72"x84" DBL SLIDING GLS DOOR BEAM PER MFG. SPEC. T W 3 4 5 1 0 B E A M P E R M F G . S P E C . DHP42510 BEAM PER MFG. SPEC. 4' - 6 1/2" 8" 1 - 1 /2 T R E A D A N K L E W A L L 8 " 8" 12 1/2" M.O. 39" 25' - 2 1/2" 1 4 ' - 6 " 3 ' - 6 " 4 ' - 6 " 3 ' - 6 " T W 3 4 5 1 0 B E A M P E R M F G . S P E C . SMOKE DET. FLOOR TRUSSES ABOVE FOR OFFICE BOX OUT 1 8 " 1 8 " 24" 96" 24" HVAC CHASE DROPPED CLG. TO ALLOW FOR HVAC 42" 42" 4 0 " 9 6 " 4 0 " 18" FLOOR TRUSSES @ 19.2" O.C. D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :0 6 P M 03 L o w e r L e v e l S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 3ply 20" lvl or w12x35 steel beam 5-1/4" x 9-1/2" or 3-1/2" x 11-7/8" treated glu-lam 5-1/4" x 11-7/8" treated glu-lam no roof load 5- 1 / 4 " x 1 4 " tr e a t e d g l u - l a m 2ply 9-1/2" lvl 2ply 9-1/2" lvl 2ply 9-1/2" lvl UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. 4 4 4 Smoke CO UP UP DN DN DN 25' - 6 1/2" 18' - 11" 9' - 6 1/2" 6' - 6" 29' - 6" 1 8 ' - 0 " 2 8 ' - 0 " 6 ' - 0 " 6' - 0" 2' - 0" 8' - 0" 2' - 0" 18' - 0" 18' - 0" 4' - 0" 24' - 0" 4 ' - 0 " 1 ' - 6 " 1 8 ' - 0 " 5 ' - 0 " 6 ' - 0 " 5 ' - 0 " 1 4 ' - 0 " 1 ' - 6 " 5 ' - 0 " 48" COOKTOP w/ HOOD 6' - 0" 6' - 0" 1' - 10" 7' - 2" 7' - 2" 1' - 10" 4' - 9" 8' - 6" 4' - 9" 4' - 0" 4' - 0" 8' - 0" 8' - 0" 4' - 0" 3 ' - 6 1 /4 " 4 ' - 6 " 4 ' - 6 " 3 ' - 6 1 /4 " 7' - 2 1/2" 6' - 9 1/2" 6' - 0" 5' - 6 1/2" 18' - 11" 4' - 6 1/2" 5' - 0" 3' - 3" 3' - 3" 2' - 6" 12' - 3" 14' - 9" 6 ' - 9 1 /4 " 7 ' - 2 3 /4 " 2 ' - 8 1 /2 " 8 ' - 6 " 3 ' - 6 " 6 ' - 0 " 8 ' - 0 " 8 ' - 0 " 1 2 " 1 2 " 3" 3" 2 0 ' - 0 1 /2 " 4 ' - 7 3 /4 " 9 ' - 1 " 1 0 ' - 2 3 /4 " 11' - 9 1/4" 18' - 5 1/2" 4' - 9 1/4" 4' - 9 1/4" 4' - 6" 2' - 8 1/4" 11' - 9 1/4" 2' - 3 1/4" 13' - 11" 2' - 3 1/4" 2' - 0" 5' - 8 1/2" 2' - 4 1/2" 6' - 7 3/4" 5' - 0 1/2" 1 3 ' - 8 3 /4 " 1 4 ' - 0 1 /2 " 8 8 " 4 9 1 /2 " 54" 54" 7 ' - 4 " 4 ' - 7 1 /2 " 4 ' - 6 " 3 ' - 6 " 4 2 " 4 8 " 119" 48" C O A T H O O K S FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.. FLOOR SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 9'- 1 1/8" UNLESS NOTED SET WINDOW HDRS @ 96" FROM MAIN LEVEL UNLESS NOTED B.P.M.S : BEAM PER MANUFACTURER SPECIFICATION NOTE: BATHROOM AND BEDROOM FLOOR OVER GARAGE: - HEAT DUCT & SEWER WRAPPED & FOAMED - HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR - 18" BLOWN INSULATION (R - 49) DW 2 - BIN TRASH 4 8 " R E F . D .O ./ M I R C O RAILINGS PER CODE (OUTSIDE) CONCRETE INSULATE WALLS & CEILING 4 - SEASON PORCH WOOD FLOORING PINE T&G CLG. 14'- 6" VAULTED CLG. DECK COMPOSITE DECKING FRONT PORCH STONE CAP PINE T&G CLG. 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . GAS OR ELEC. FIREPLACE PER MFG. SPECS. 204"x96" CASED OP'NG BEAM DROPPED PER MFG. SPEC. GARAGE FAN 4 8 " V A N I T Y BATH TILE FLOOR OFFICE WOOD FLOOR KITCHEN WOOD FLOOR STAIRS CARPET FLOOR SPILT LNDNG GREAT ROOM WOOD 1 4 4 "x 9 6 " C .O . dinning room WOOD FLOOR foyer WOOD SHIPLAP CLG P'TRY WOOD FLOOR BENCH & LOCKERS 72"x96" DOUBLE GLASS ENTRY DR. BEAM PER MFG SPEC 3 2 "x 9 6 " S E R V I C E D R . B E A M P E R M F G S P E C MUD ROOM TILE FLOOR SD/CO NOTE: 16'- 0" x 8'- 0" DOOR BEAM PER MFG SPEC BATHROOM AND BEDROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 5 0 9 UPPERS UPPERS U P P E R S SHELVES (WHITE MELAMINE) R &S 1 ) 4 8 "x 9 6 " D B L D R C L O S E T1) 30"x96" DOOR 1 8 ' - 2 3 /4 " 2 ' - 1 1 1 /2 " 6 ' - 1 1 /2 " 4 ' - 7 3 /4 " 8 ' - 0 1 /2 " 1 ) 3 0 "x 9 6 " D O O R 2X6 WALL 7 ' - 9 1 /4 " 1 4 ' - 2 3 /4 " 2X6 BEARING WALL 2X6 BRNG/PLMNG WALL 1 ) 6 0 "x 9 6 " D B L D O O R 36"x96" C.O. B.P.M.S.D 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . CONCRETE INSULATE WALLS & CEILING GARAGE 9 '- 0 " x 8 '- 0 " D O O R B E A M P E R M F G S P E C BEAM FLUSHED PER MFG. SPEC. NOTE: SLOPE CONC. FLOOR TOWARDS FLOOR DRAINS 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 4 09 1 06 3 07 2 06 3 06 1 07 5 08 4 06 R O O F G I R D E R P E R M F G . S P E C . ROOF GIRDER PER MFG. SPEC. F L O O R G I R D E R P E R M F G . S P E C . BEAM FLUSH PER MFG. SPEC. 16" OVERHANG 2 X 6 P L U M B I N G W A L L 36"x96" C.O. B.P.M.S.D LINE OF CANT. ABOVE BATHROOM FLOOR OVER UNCONIDTIONED SPACE: - HEAT DUCT & SEWER WRAPPED & FOAMED - HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR - 18" BLOWN INSULATION (R - 49) 6 ' - 0 " 4 ' - 0 " 3 08 S T E E L B E A M D R O P P E D P E R M F G . S P E C . STEEL BEAM DROPPED PER MFG. SPEC. PORCH COLUMN SUPPORTING STEEL BEAMS CONSTRUCTION: 2x8 TOP/BOTTOM COLLAR 3/4" COMPOSITE WRAP 1/2" PLYWOOD 2X4 FRAMED BOX 6X6 TRD STRUCTURAL POST PER MFG. SPEC. 1 08 1) 34"x96" PKT DR BEAM FLUSHED PER MFG. SPEC. 1 08 2 08 2 04 L I N E O F D O R M E R A B O V E L I N E O F D O R M E R A B O V E FLOOR GIRDER PER MFG. SPEC. BEAM DROPPED PER MFG. SPEC. Soffit 16" S o f f i t 1 6 " 1 - 1 /2 T R E A D A N K L E W A L L 6 08 W O O D F I R E P L A C E P E R M F G . S P E C S . 5 06 4 08 108"x96" TRIPLE SLIDING GLASS PATIO DOOR BEAM PER MFG. SPEC. F W G 1 2 0 6 1 1 - 4 B E A M P E R M F G . S P E C . 3 ) T W T 2 4 2 3 B E A M P E R M F G . S P E C . TW2662 - 2 BEAM PER MFG. SPEC. TW2662 BEAM PER MFG. SPEC. TW2662 BEAM PER MFG. SPEC. TW2652 BEAM PER MFG. SPEC. TW2652 BEAM PER MFG. SPEC. 3) TW210310 BEAM PER MFG. SPEC. 1 ) 3 6 "x 9 6 " D R B E A M P E R M F G . S P E C . TWT3831 BEAM PER MFG. SPEC. DHP42510 BEAM PER MFG. SPEC. TW3862 BEAM PER MFG. SPEC. TW3862 BEAM PER MFG. SPEC. DHP41062 BEAM PER MFG. SPEC. T W 3 4 6 2 B E A M P E R M F G . S P E C . T W 3 4 6 2 B E A M P E R M F G . S P E C . T W 3 4 6 2 B E A M P E R M F G . S P E C . S T E E L B E A M D R O P P E D P E R M F G . S P E C . BEAM FLUSHED PER MFG. SPEC. A.C. PAD G A S & E L E C T R I C S E R V I C E L O C A T I O N S o f f i t 1 6 " F L O O R G I R D E R P E R M F G . S P E C . R O O F T R U S S E S @ 2 4 " O .C . R O O F T R U S S E S @ 2 4 " O .C . 5 4 ' - 6 "5 2 ' - 0 " 1 ) 3 0 "x 9 6 " D O O R HVAC CHASE SINK FLOOR TRUSSES ABOVE 7)TW3876 BEAM PER MFG. SPEC. @ 102" FROM M.L. 2 ' - 8 1 /2 " 2' - 8 1/2" 6" 13 1/2" 6" 13 1/2" FWG31611AL BEAM PER MFG. SPEC. FWG31611AR BEAM PER MFG. SPEC. 2 7 3 /4 " 6' - 1 3/4" 6' - 7 1/2" 6' - 1 3/4" D H P 5 6 6 2 B E A M P E R M F G . S P E C . 1 6 " 1 6 " 1 2 " W O O D B E A M /1 0 " P R O J E C T I O N 50" 10" 96" 10" 50" 1 0 " W O O D B E A M /1 0 " P R O J E C T I O N 1 2 " W O O D B E A M /1 0 " P R O J E C T I O N NOTE: SLOPE CONC. FLOOR TOWARDS FLOOR DRAINS F.D. F.D. NOTE: RUN GAS LINE FOR FUTURE HEATER RUN HOT/COLD WATER TO GARAGE WOOD FLOOR w/CARPET RUNNER 10" 4 2 " H e e l 7 3 /4 " L o w e r S t e p o f L a n d i n g T o C l g . 1 4 ' - 2 3 /4 " L a n d i n g t o L a n d i n g 1 1 ' - 0 1 /4 " 5 ' - 2 1 /4 " 2 4 1 /4 " L a n d i n g T o W i n d o w R .O . 1 0 8 " S l a b t o L a n d i n g 6 2 1 /4 " 1 3 1 /8 " 4 8 " L o w e r S t e p o f S t e p p e d L a n d i n g T o W i n d o w R .O . 1 0 1 " 8 5 /8 " BEAMS FLUSH PER MFG. SPEC. BEAMS FLUSH PER MFG. SPEC. T .O .F . t o T a l l W a l l H g t . 3 0 ' - 1 3 /4 " 5 1/2" ROOF TRUSSES PER MFG. SPEC. Ovr'Hng 18" STRUCTURAL ENGINEER TO VERIFY TALL WALL CONSTRUCTION INCLUDING WALL FRAMING, BEAMS, AND HEADERS IMPORTANT NOTE: U.L. M.L. D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :0 7 P M 04 M a i n L e v e l S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 3/8" = 1'- 0" 2 Detail - Stairwell Tall Wall 3ply 20" lvl or w12x35 steel beam 2ply 11-7/8" lvl 2ply 11-7/8" lvl corner to corner 2ply 11-7/8" lvl corner to corner 3p l y 1 6 " o r w 1 0 x 2 6 st e e l b e a m 3ply 16" or w10x26 steel beam 2ply 9-1/2" lvl 3ply 16" lvl 2ply 9-1/2" lvl 2p l y 1 1 - 7 / 8 " " l v l co r n e r t o c o r n e r 2ply 9-1/2" lvl 3p l y 1 8 " l v l 2ply 18" lvl 2ply 9-1/2" lvl 2ply 9-1/2" lvl Large point loads near 10,000 lbs, remove plates at bearing for crushing. TE M P E R 4 4 4 4 CS-PF CS-PF 4 4 CS-PF CS-PFCS-PF 4 4 CS-PF CS-PF TEMPER glass if within 36" of landing Smoke 4 (2 ) 1 1 - 7 / 8 " L V L p e r w a l l br a c i n g e n g i n e e r i n g d e t a i l 1 4 B 3p l y 1 8 " l v l 11' - 6 1/2" 18' - 11" 9' - 6 1/2" 12' - 0" 8 ' - 0 " 8 ' - 6 " 2 9 ' - 6 " 6 ' - 0 " 4 ' - 0 " 1 6 ' - 0 " C A N T . 2 ' - 0 " 3 0 ' - 0 " 4 09 1 06 2 06 3 06 1 07 5 08 4 06 11" 2 ' - 2 3 /4 " 9 ' - 5 1 /2 " 3 ' - 1 0 1 /2 " 2 ' - 4 1 /2 " 1 4 ' - 0 3 /4 " 1 ' - 1 0 1 /2 " 7' - 4 1/2" 4' - 2" 2' - 11 1/2" 6' - 6" 6' - 6" 2' - 11 1/2" 4' - 6 1/2" 5' - 0" 6' - 2 7/8" 5' - 9 1/8" 3' - 0 1/2" 4' - 8 1/4" 5' - 0" 4 ' - 7 1 /2 " 7 ' - 4 " 51 3/4" 4 1/2" 51 3/4" 9" ROOF TRUSSES ARE CALLED OUT AT 24" O.C. ROOF SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 8'- 1 1/8" UNLESS NOTED SET WINDOW HDRS @ 84" FROM UPPER LEVEL NOTE: WSHR w/ FLOOR DRAIN DRYER 36"x66" FREE - STANDING TUB 3 0 "x 6 0 " F B R G L S T U B / S H W R 36" LINEN BATH LVT FLOOR 1) 28"x80" DOOR F L O O R T R U S S E S R &S SMOKE DET. OWNER'S SUITE CARPET FLOOR 14' 1 - 5/8" VAULT 3 4 "x 8 0 " D O O R FAN 6 0 " V A N I T Y 81"x42" CUSTOM TILE SHWR OwnER'S BATH TILE FLOOR 30"x80" DOOR A N K L E W A L L W / R A I L I N G STAIRS CARPET w/ STEPPED LNDNG R&S HALL WOOD FLOOR NOTE: BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). F L A T C L G . 4 8 " C O S . D E S K 6 6 " V A N I T Y 2 X 6 P L M N G 2 X 6 P L M N G W A L L 2X6 PLMNG WALL 2X6 PLMNG WALL 2X6 WALL 2X6 WALL 2X6 PLMNG WALL 2X6 WALL 2X6 WALL 2 X 6 W A L L 30"x80" PKT DR. 30"x80" C.O. 2 8 "x 8 0 " D O O R 2 4 "x 8 0 " G L S D R .GLASS WALL FAN LAUNDRY LVT FLOOR OWNER'S W.I.C CARPET FLOOR UPPERS A T T I C A C C E S S gallery WOOD FLOOR SMOKE DET. SMOKE DET. SMOKE DET. LVT FLOOR BATH LVT FLOOR LVT FLOOR 3 4 "x 6 0 " F B R G L S S H W RFAN FAN 49" VANITY 6 6 " V A N I T Y 5 3 " V A N I T Y 1 ) 2 8 "x 8 0 " P K T D R 1 ) 2 8 "x 8 0 " D O O R 1) 28"x80" PKT DR 1) 28"x80" PKT DR 1) 30"x80" DOOR 1) 30"x80" DOOR 3 2 "x 8 0 " P K T D R 1) 48"x80" DBL DR 1) 28"x80" DOOR 1) 30"x80" DOOR M I R R O RDRESSING AREA CRPT BEDROOM #2 CARPET FLOOR BEDROOM #3 CARPET FLOOR W.I.C. CARPET FLOOR W.I.C. CARPET FLOOR 1 ' - 9 3 /4 " BEDROOM #4 CARPET FLOOR R&S SMOKE DET. 1) 72"x80" DBL DR SNK l i n e n SMOKE DET. workstation WOOD FLOOR B U I L T I N D E S K FALSE GARAGE DORMER 2X6 FRAMING 6" 3" 3" 2)TWT2423 WNDWS @ 15'- 0" FROM T.O.F. 7' - 0" 10' - 0" 7' - 0" 60" 60" LINE OF GARAGE BELOW LINE OF GARAGE BELOW T W T 2 4 2 3 @ 1 9 '- 6 " F R O M T .O .F . 1 1 ' - 1 0 " 1 6 ' - 2 " R A I L I N G 4 8 ' - 0 " 12' - 0" 20' - 6" 13' - 0" 6' - 6 1/2" 3 08 1 ) 2 8 "x 8 0 " D O O R 6" 6" 6" 6" 52' - 0 1/2" 6' - 0" 6' - 0" 9' - 0" 11' - 6" 6' - 6" 6' - 6" 6 ' - 6 " 4 ' - 5 1 /2 " 6 ' - 0 1 /2 " 4 ' - 1 1 1 /2 " 1 1 ' - 8 3 /4 " 7 " 33 3/4" 4 ' - 2 1 /4 " 9 ' - 8 1 /2 " 1 ' - 5 1 /2 " 2 ' - 0 1 /4 " 6 ' - 8 " 6' - 2 1/4" 7' - 3" 2' - 0" 7' - 4" 3' - 3 1/2" 4' - 2" 4' - 9 1/4" 5' - 9 1/2" 11' - 2 1/2" 1 8 ' - 3 3 /4 " 3 ' - 1 1 1 /2 " 5 ' - 5 " 5 ' - 8 " 5 ' - 5 1 /2 " 5 ' - 2 1 /4 " 12 1/4" 26 1/4" 2 08 2 04 6 08 FLOOR TRUSSES F L O O R T R U S S E S FLOOR TRUSSES LINE OF GARAGE BELOW 5 06 4 08 TW2652 - 2 BEAM PER MFG. SPEC. TWT2023 BEAM PER MFG. SPEC. 3)TW2652 BEAM PER MFG. SPEC. T W T 2 0 1 1 1 B E A M P E R M F G . S P E C . CXW245 w/ SDLS BEAM PER MFG. SPEC. DHP310310 DHP310410 TEMPERED BEAM PER MFG. SPEC. TW21052 BEAM PER MFG. SPEC. TW21052 BEAM PER MFG. SPEC. TWT34111 TW3452 BEAM PER MFG. SPEC. DHP 31052 BEAM PER MFG. SPEC. 2 ' - 2 3 /4 " 9 ' - 5 1 /2 " 3 ' - 1 0 1 /2 " 1 ' - 9 1 /2 " 5 ' - 5 1 /2 " 9 ' - 2 1 /4 " 3' - 9 1/4" 7' - 6 1/2" 3' - 5" 1' - 7 1/2" 2 X 6 W A L L FLOOR TRUSSES ROOF TRUSSES @ 24" O.C. ROOF TRUSSES @ 24" O.C. ROOF TRUSSES @ 24" O.C. R O O F T R U S S E S @ 2 4 " O .C . 8 ' - 0 " B E N C H R.H. HANGING ROD WOOD FLOOR w/CARPET RUNNER 4 2 " 10" L o w e r L e v e l W i n d o w H e i g h t 8 4 " U p p e r L e v e l W i n d o w H e i g h t 8 4 " L o w e r L e v e l C e i l i n g H e i g h t 8 ' - 1 0 " 1 ' - 6 3 /4 " M a i n L e v e l C e i l i n g H e i g h t 1 0 ' - 1 1 /8 " 1 ' - 6 3 /4 " U p p e r L e v e l C e i l i n g H e i g h t 8 ' - 1 1 /8 " 18" ROOF, CEILING & EAVE CONSTRUCTION: WALL CONSTRUCTION: FOUNDATION WALL & BASEMENT SLAB CONSTRUCTION: MAIN LEVEL CONSTRUCTION: UPPER LEVEL CONSTRUCTION: ARCHITECTURAL GRADE ASPHALT SHINGLES #15FELT & ICE & WATER SHIELD (6'- 0") 1/2" OSB SHEATHING w/STEEL CLIPS TRUSSES @ 24" O.C. (PER MFG. SPEC.) BAFFLES w/1" AIR SPACE 2X4 LOOKOUTS 2X8 SUB FASCIA w/ 8" METAL FASCIA ALUMINIUM VENTED SOFFITS COMPOSITE FRIEZE BOARDS R - 50 BLOWN INSULATION POLY VAPOR BARRIER 5/8" GYP. BRD. CEILING 3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED 18" FLOOR TRUSSES @ 19.2" O.C. (FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS) 5/8" GYP. BRD. ON CEILING SPRAY INSULATE RIMS (R - 21) SIDING PER ELEVATION HOUSE WRAP (WRAP WINDOWS PER MFG. SPEC.) 1/2" OSB SHEATHING 2X6 STUDS @16" O.C. DBL. TOP PLATE R - 21 WALL INSULATION 4 MIL POLY VAPOR BARRIER 1/2" GYP. BRD. 2X6 SOLE PLATE ALL DETAILS TO CONFORM W/ ENERGY CODE 3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED 18" FLOOR TRUSSES @ 19.2" O.C. (FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS) FLASHING UNDER SILLS & STOOPS TREATED 2X6 SILL PLATE w/ SEALER 1/2" ANCHOR BOLTS @ 6' O.C. & 1' FROM CORNERS 5/8" GYP. BRD. ON CEILING SPRAY INSULATE RIMS (R - 21) WATERPROOFING EXTERIOR THERMAL WALL: 2" RIGID INSULATION (R - 10) APPLIED TO EXTERIOR, PROVIDE FLASHING TO COVER EXPOSED INSULATION POURED CONC. WALL PER PLAN REINFORCE WALLS PER CODE AND ENGINEER'S SPECIFICATIONS 20" X 8" CONTINUOUS CONC. FOOTING UNLESS OTHERWISE NOTED 4" CONC. SLAB VAPOR/MOISTURE BARRIER PER IRC SECTION 506 EXTENDING UP THE WALL AND SEALED TO FOUNDATION WALL 4" SAND/AGGREGATE FILL INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TO SUMP BASKET INTERIOR THERMAL WALL: 1" RIGID INSULATION (R - 5) 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. M a i n L e v e l W i n d o w H e i g h t 9 6 " D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :0 8 P M 05 U p p e r L e v e l S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 1/2" = 1'- 0" 2 Detail - Typical Wall Section TEMPERED -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 4 4 4 4 4 4 4 Smoke CO Smoke CO (2 ) 7 - 1 / 4 " L V L or ( 3 ) 2 x 1 0 (3)2x10 or (2)2x12 or (2)7-1/4 LVL H e e l 8 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAIN SAND BED GRANULAR FILL TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL NOTE: BEDROOM & BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " T .O .F . T o G a r a g e C l g . 1 1 ' - 9 3 /8 " 7' - 4" 6' - 0" 6' - 0" 7' - 2 1/4" 4' - 11 3/4" 5' - 9 7/8" 9' - 0" 13' - 0" H e e l 8 " H e e l 2 ' - 5 " H e e l 2 ' - 5 " H e e l 9 7 /8 " 2' - 0" Ovr' Hng 16" 9 ' - 0 " 4 2 " 4 2 " 4 2 " 7 1 /4 " S t o n e C a p 2 1 /4 " 18" 12" 18" 12" ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. L o w e r L e v e l C l g . H g t . 9 ' - 1 1 /2 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " 1 6 3 /4 " garage bedroom #3 bedroom #2 office Guest Bath F r o n t P o r c h C l g . H g t . 9 ' - 6 1 /2 " ROOF TRUSSES PER MFG. SPEC. STEEL BEAM DROPPED PER MFG. SPEC. 1 1 1 /4 " FLOOR GIRDER TRUSSES PER MFG. SPEC. 6' - 6" 13' - 0" 2' - 6" T .O .F . T o G a b l e W i n d o w 1 9 ' - 6 " 4 2 " 4 2 " H e e l 7 3 /8 " 16' - 2" 11' - 10" 14" 12" 6" 12" H e e l 1 1 1 /4 " H e e l 2 1 1 /2 " Ovr'hng 24" Ovr'hng 24" T .O .F . F r o n t D o r m e r W i n d o w 1 5 ' - 0 " 2x6 FRAMING GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAIN SAND BED GRANULAR FILL GARAGE WALLS: INSULATE WALLS & CLG. 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS garage FALSE DORMER M a i n S t a l l C l g . H g t . 1 0 ' - 1 1 /8 " 10" 4 2 " 9 ' - 0 " 4 2 " H e e l 7 3 /4 " Ovr'Hng 18" 21' - 0" 24' - 6" Ovr'hng 18" Ovr'Hng 24" Ovr'Hng 42" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL TYPICAL STAIRCASE CONSTRUCTION: 6'- 10" MINIMUM HEADROOM (3) 11 - 7/8" STAIR STRINGER w/1 - 1/8" x 11 - 1/4" PARTICLE BOARD TREADS PROVIDE 34" - 36" HGT HANDRAILS & GUARDS RAILS PER CODE TYPICAL STAIRCASE LANDING CONSTRUCTION: 2 - 2x8 HEADER 3/4" PLYWOOD BACKING 2x8 JOISTS @ 16" O.C. 3/4" PLYWOOD TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL NOTE: BATHROOM & BDRM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE 14" 12" 8" 12" 4 1/2" 12" 1 1 1 /4 " T .O .F . t o G a r a g e C l g . H g t 1 0 ' - 1 1 /8 " 2 0 1 /4 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. GARAGE PANTRY GAME ROOM STAIRwell BEDROOM # 3 HANDFRAME DOWN CLG. HGT. TO 10'- 1 1/8" WALK IN CLOSET BDRM #4 J&j BATH T .O .F . t o B .O . F l o o r T r u s s e s 1 1 ' - 9 3 /8 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. 11" 7 3 /8 " 1 4 ' - 2 3 /4 " 1 1 ' - 0 1 /4 " 5 ' - 2 1 /4 " 7 2 " 3 6 " 6 2 1 /4 " 1 3 1 /8 " 4 8 " 6 0 " 4 1 " 8 5 /8 " SEE DETAIL ON PG A04 - 2 BEAM FLUSH PER MFG. SPEC. BEAM FLUSH PER MFG. SPEC. BEAMS FLUSH PER MFG. SPEC. BEAMS FLUSH PER MFG. SPEC. 8 ' - 3 " 11" 7 3 /8 " 26" 1 2 " DROPPED CLG. TO ALLOW FOR HVAC BEAM DROPPED PER MFG. SPEC. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. H e e l 1 9 5 /8 " ROOF TRUSSES PER MFG. SPEC. 18" 24" 18" 72" F r o n t P o r c h C l g . H g t . 9 ' - 6 1 /2 " 8" 12" 4 1/2" 12" NOTE: OFFICE OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). OFFICE GUEST W.I.C. BATH bedroom # 2 L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " BEAM DROPPED PER MFG. SPEC. 27" CANT. 24" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. NOTE: BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). H e e l 6 1 /4 " 15' - 0" 12" BEAM FLUSHED PER MFG. SPEC. 5 1/2" 6" 12" 14" 12" DINING ROOM owner's luxury bath bath cl' st M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :1 2 P M 06 C r o s s S e c t i o n s S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N 1/4" = 1'- 0" 1 Cross Section - Bedroom 2&3, Front Porch @ Entry 1/4" = 1'- 0" 2 Cross Section - Main Garage Stall 1/4" = 1'- 0" 3 Cross Section - Stairwell and Garage 1/4" = 1'- 0" 4 Cross Section - Office Box Out 1/4" = 1'- 0" 5 Cross Section - Owner's Lux Bath Cantilever T .O .F . T o F r o n t D o r m e r W i n d o w 1 5 ' - 0 " T .O .F . M a i n S t a l l C l g . H g t . 1 0 ' - 1 1 /8 " 2 0 1 /4 " FLOOR GIRDER TRUSS PER MFG. SPEC. LINE OF VAULT PINE T&G PORCH CLG. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAIN SAND BED GRANULAR FILL 2X10 JOISTS @ 16" O.C. TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL GARAGE 9 ' - 0 " 9 ' - 0 " 4 2 " M .L . T o S c r e e n P o r c h C l g . H g t . 1 0 ' - 1 1 /8 " T o S c r e e n P o r c h V a u l t P e a k 1 4 ' - 6 1 /8 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. SCISSOR TRUSSES PER MFG. SPEC. C a s e d O p e n i n g 9 6 " GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE Ovr'Hng 12" Ovr'Hng 12" 21' - 0" 19' - 0" 12' - 0" 18" 12" ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. METAL SEAM ROOF 6:12 SLOPE ROOF TRUSSES PER MFG. SPEC. Ovr'hng 18" 7' - 0" 10' - 0" 7' - 0" 6" 6" 29 1/2" 4 2 1 /2 " T .O .F . T o B .O . F l o o r T r u s s e s 1 1 ' - 9 3 /8 " 2 0 1 /4 " HANDRAME CLG HGT. DOWN TO 10'- 1 1/8" NOTE: BATHROOM & BDRM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). GARAGE WALLS: INSULATE WALLS & CLG. 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS MUDROOM BEDROOM #4 HALL LAUNDRY MUDROOM OWNER'S LUX. BATH STORAGE ROOM GAME ROOM WET BAR GUEST ROOM KITCHEN DINING ROOM PANTRY CL' ST C a s e d O p e n i n g 9 6 " C a s e d O p e n i n g 9 6 " C a s e d O p e n i n g 9 6 " 4 - SEASON porch 14' - 0" Ovr'Hng 12" BEAM DROPPED PER MFG. SPEC. C H I M N E Y S T A C K H E I G H T 2 4 ' - 0 " DROPPED CLG. TO ALLOW ROOM FOR HVAC 1 0 " DROPPED SOFFIT OVER WET BAR CABINETRY TO MATCH DROPPED CLG. HGT. 8 ' - 0 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " 29 1/2" METAL FLASHING 5/4" x 8" TRIM 2" RIGID INSULATION 2X2 BLOCKING LAP SIDING 1/2" SHEATHING 2X6 SILL PLATE 1/2" ANCHOR BOLT 2X2 BLOCKING 2 " BUILDING PAPER SILL PLATE DETAIL: STANDARD FOUNDATION: ALL STRUCTURAL EXTERIOR FOUNDATION WALLS MUST BE WRAPPED w/ 8" TRIM BOARD AND FLASHED PER CODE DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL FOUNDATION WALLS (STRUCTURAL AND NON - STRUCURAL) MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR FOUNDATION WALLS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE. NOTE: WALKOUT WALL DETAIL: TYPICAL FOUNDATION: 3'- 6" OR 5'- 0" x 10" POURED CONCRETE FOUNDATION WALL ON 20" x 8" CONCRETE FOOTING REBAR PER CODE NOTE: DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL FOUNDATION WALLS (STRUCTURAL AND NON - STRUCURAL) MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR FOUNDATION WALLS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE. 5 1/2" 4 1/2" 10" 3 1 /2 " 2 " I N S U L A T I O N LAP SIDING PER PLAN BUILDING PAPER 1/2" PLYWOOD 2X6 STUDS @ 16" O.C. INSULATION PER CODE FLASHING GYP. BRD. 2" INSULATION @ 45 DEGREE ANGLE 1/2" ANCHOR BOLT 4" SAND 5 /4 " x 6 " T R I M B D . 5/4" x 6" TRIM BD. 5 /4 " x 6 " T R I M B D . 5/4" x 6" TRIM BD. 2" x 2" TRIM BD. 2" 2" x 2" TRIM BD. 2" 2" 8 ' - 1 1 1 /4 " 4 2 " 9 ' - 0 " 4 2 " 10" F a m i l y R o o m C a s e d O p e i n g 9 6 " G r e a t R o o m O p e n i n g 9 6 " S o f f i t 2 5 1 /8 " 10" 1 0 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL H e e l 1 6 1 /8 " B .O . O w n e r ''s S u i t e F l a t . C l g . 8 ' - 1 1 /8 " L o w e r L e v e l C l g . H g t 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " T .O . O w n e r 's S u i t e V a u l t 1 4 ' - 1 5 /8 " ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. T .O . T r n s m W n d w R .O . 9 ' - 0 " SLOPED CLG. GREAT ROOM FAMILY ROOM OWNER'S SUITE DRESSING AREA OWNER'S WALK IN CLOSET BATH GALLERY FOYER KITCHEN WET BAR MECHANICAL ROOM 7 1 /4 " P o r c h C l g . H g t . 9 ' - 6 3 /4 " 11' - 6" Slab to Ovr'Hng 12" LINE OF M.L. 4 1/2" 12" 14" 12" 8" 12" 31' - 0" 13' - 0" Ovr'Hng 24" ROOF TRUSSES PER MFG. SPEC. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. front porch BEAM DROPPED PER MFG. SPEC. BEAM DROPPED PER MFG. SPEC. H e e l 1 3 5 /8 " 26" 1 2 " DROPPED SOFFIT D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :1 3 P M 07 C r o s s S e c t i o n s S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N 1/4" = 1'- 0" 3 Cross Section - Main Garage Stall, Mudroom, 4 - Season Porch 1" = 1'- 0" 2 Truss Detail - Standard Sill Plate 1" = 1'- 0" 4 Detail - 10" Walkout Wall 1" = 1'- 0" 5 Stool & Apron Trim Detail 1/4" = 1'- 0" 1 Cross Section - Front Entry, Front Porch, Owner's Suite Vault 9 ' - 0 " 4 2 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " 1 1 1 /4 " 6' - 0" 7' - 4" Ovr'Hng 12" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. 18" 12" 18" 12" GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE WORK - STATION BATH BEDROOM #2 foyer office guest w.i.c. hall way mechanical room M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " STEEL BEAM DROPPED PER MFG. SPEC. P o r c h S l a b T o C l g . H g t . 9 ' - 6 1 /2 " T&G CLG. 50" 10" 96" 10" 50" 1 0 "10x10 WD BEAMS 1 4 ' - 1 5 /8 " 4 2 " 4 2 " 5 ' - 1 5 /8 " B .O . V a u l t C l g . H g t . 8 ' - 1 1 /8 " 2' - 11 1/2" 6' - 6" 6' - 6" 2' - 11 1/2" 18" 12" 12" 12" owner's suite great room family room L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL 18" 18" H e e l 1 1 1 /4 " H e e l 1 1 1 /4 " 9 ' - 0 " 4 2 " T .O .F . t o B .O . F l o o r T r u s s e s 1 1 ' - 9 3 /8 " T .O .F . T o G a r a g e C l g . H g t . 1 0 ' - 1 1 /8 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " 13' - 0" Ovr'Hng 12" 24" 2 0 1 /4 " GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAIN SAND BED GRANULAR FILL GARAGE NOTE: BATHROOM & BDRM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). GARAGE WALLS: INSULATE WALLS & CLG. 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS HANDFRAME CLG. DOWN TO 10'- 1 1/8" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. 18" 12" 18" 12" BEDROOM #3 WORK - STATION BATH RAILING (PER CODE OUTSIDE) 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. SCISSOR TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAIN SAND BED GRANULAR FILL 2X10 JOISTS @ 16" O.C. TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL deck 5 ' - 1 5 /8 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " T .O . O w n e r 's S u i t e V a u l t 1 4 ' - 1 5 /8 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " H e e l 1 1 1 /4 " Ovr'Hng 18" 29' - 0 1/2" 6' - 11 1/2" 18" 6" 19' - 0" 9' - 5 1/2" 4 2 " 9 ' - 0 " 4 2 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. 2 0 1 /4 " T .O .F . t o G a r a g e C l g . H g t . 1 0 ' - 1 1 /8 " 8 ' - 1 1 /8 " 9' - 2" 6' - 0 1/2" 12" 12" 18" 12" GARAGE NOTE: BATHROOM & BDRM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). GARAGE WALLS: INSULATE WALLS & CLG. 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS storage room 1/2 bath stairs owner's suite great room family room 1 4 ' - 2 3 /4 " 1 1 ' - 0 1 /4 " 4 ' - 1 0 3 /4 " 18" 6" M .L . T o S c r e e n P o r c h C l g . H g t . 1 0 ' - 1 1 /8 " 30" 30" 8' - 0" 8' - 0" 7" 12" 14" 12" PINE T&G PORCH CLG. SCISSOR TRUSSES PER MFG. SPEC. 2X10 JOISTS @ 16" O.C. screen porch deck RAILING PER CODE (OUTSIDE) BEAMS FLUSH PER MFG. SPEC. BEAM FLUSH PER MFG. SPEC. 6" WD MNTL 2" BRICK VENNER H e e l 2 6 7 /8 " H e e l 2 6 7 /8 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. 3" MIN. ABS OR PVC OR EQUIVALENT GAS TIGHT PIPE SEAL ALL JOINTS BETWEEN SLAB AND FOUNDATION WALL 4" PERFORATED DRAIN TILE W/FILTER FABRIC 8"X16" ROCK TRENCH SEALED SUMP BASKET MIN 6 MIL OR 3 MIL CROSS LAMINATED POLY SHALL BE LAPPED 12" AND PLACED BELOW THE SLAB AND ON TOP OF 4" MIN. SAND GAS PERMEABLE LAYER INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOOR AND IN ACCESSIBLE ATTICS ALL CONTROL JOINTS, ISOLATION JOINTS CONSTRUCTION JOINTS AND ANY OTHER JOINTS IN CONCRETE SLABS SHALL BE SEALED WITH CAULK OR SEALANT SEAL ALL FLOOR OPENINGS ALL PIPE JOINTS AND FITTINGS TO BE GLUED OR TRANSITION COUPLINGS PROVIDE SPACE FOR FUTURE INSTALLATION OF A FAN *MIN. 24' DIAMETER CENTERED ON THE AXIS OR THE VENT STACK *MIN. VERTICAL DISTANCE 36" INSTALL LIVE OUTLET IN ATTIC WHERE FUTURE FAN MAY BE INSTALLED R - 4 MIN. INSULATION AROUND PIPE IN UNCONDITIONED SPACES D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :1 5 P M 08 C r o s s S e c t i o n S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N 1/4" = 1'- 0" 2 Cross Section - Garage, Foyer, Bedroom 2 1/4" = 1'- 0" 3 Cross Section - Owner's Suite Vault 1/4" = 1'- 0" 4 Cross Section - Garage, Foyer, Bedroom 3 1/4" = 1'- 0" 5 Cross Section - Owner's Suite Vault and Stairwell 1/4" = 1'- 0" 1 Cross Section - Screen Porch 3/8" = 1'- 0" 6 Detail - Passive Radon System UP UP UP DN DN DN DN DN LOWER LEVEL 1261 SQ. FT mech. room 124 SQ. FT st'rg 139 SQ. FT main level 1599 SQ. FT deck 306 SQ. FT 4 - SEASON porch 221 SQ. FT wrap around porch 383 SQ. FT garage 1198 SQ. FT upper level 1804 SQ. FT stairs 105 SQ. FT 9 ' - 0 " 1 1 6 1 /4 " 4 2 " 4 2 " BEAM FLUSHED PER MFG. SPEC. HANDFRAME SOFFIT & EAVE 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL BEDROOM FLOOR OVER GARAGE: - HEAT DUCT & SEWER WRAPPED & FOAMED - HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR - 18" BLOWN INSULATION (R - 49) TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL POLY/VAPOR BARRIER OVER 6" SAND BED GRANULAR FILL storage room 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. U .L . T o G a b l e W i n d o w 1 3 ' - 6 " L o w e r L e v e l C l g . H g t . 8 ' - 1 0 " U p p e r L e v e l C l g . H g t . 8 ' - 1 1 /8 " hall 1/2 bath mudroom bedroom #4 bedroom #3 J&J bath H e e l 7 1 /4 " 4' - 6" 14' - 6" 21' - 0" 1' - 6" 12" garage 14" 12" 6" 12" H e e l 7 3 /8 "4 1/2" 12" 1 ' - 8 1 /4 " T .O .F . T o B .O . F l o o r T r u s s e s 1 1 ' - 9 3 /8 " 8 ' - 4 7 /8 " 2 0 1 /4 " T .O .F . T o G a r a g e C l g . H g t . 1 0 ' - 1 1 /8 " FRAME DOWN TO CLG. HGT. 10" Ovr'Hng 42" M a i n L e v e l C l g . H g t . 1 0 ' - 1 1 /8 " 8" 12" TWT 2423 BEAM PER MFG. SPEC NOTE: SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. VERIFY DESIGN WITH INTERIOR DESIGNER AND HOMEOWNER TV LOCATION CUSTOM BRACKET #1 DETAIL SIDE VIEW FRONT VIEW 3 6 " 15" 5 1/2" 3 6 " 2 " 1 1 /2 " 2 8 1 /4 " 3 /4 " 1 /2 " 3 " 5 1/2" 5 1/2" 3 1/2" 3 1 /2 " 4 1 /4 " 2 8 1 /4 " 3 1 /2 " 1 /2 " 7 /1 6 " 3 5 /1 6 " 1" 2" 1" 1 1/2" 5 0 3 / 4 " R A D I U S 1" D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 5 /2 2 /2 0 1 8 4 :5 4 :1 5 P M 09 S q u a r e F o o t a g e C a l c u l a t i o n s S D - T h e P e r r o n R e s - C D 's - L M C P e r r o n R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 0 5 .0 3 .1 8 L M C L a k e v i l l e , M N LOWER LEVEL: MAIN LEVEL: UPPER LEVEL: FINISHED TOTAL: SQUARE FOOTAGE CALCULATIONS 1261 SQ. FT. LOWER LEVEL 124 SQ. FT. MECHANICAL ROOM 139 SQ. FT. PATIO 1599 SQ. FT. MAIN LEVEL 1198 SQ. FT. GARAGE 221 SQ. FT. SCREEN PORCH 306 SQ. FT. DECK 383 SQ. FT. FRONT PORCH 1804 SQ. FT. UPPER LEVEL 105 SQ. FT. STAIRS 4664 SQ. FT. FINISHED TOTAL GENERAL NOTES 1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C. 2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS OTHERWISE NOTED) 3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING 4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR. 5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD 6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND 50% AT SOFFIT - MIN 7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILER UNLESS OTHERWISE NOTED. UNDERCUT MIN 1" 8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER. 9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF A DOORWAY SHALL BE TEMPERED GLASS 10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR EQUIVALENT 11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR 12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES 13. 1/2" AIR SPACE ON EACH SIDE OF MICRO - LAM BEAM & MIN 3" BEARING ON CONCRETE 14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE TO PASS THROUGH 15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE 16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY 17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS 18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE 19. PROVIDE DRAFT STOPS PER UBC 708.3 20. FIRE BLOCK ALL CHASES AT EACH FLOOR - CEILING ASSEMBLY OR AT 10' MAX INTERVALS 21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE 22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD 23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS 24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED MATERIALS 25. BLOCK PATIO DOORS WITHOUT A DECK 26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC 27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES 28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE ROOMS 29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE STAIRS 30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN REQUIRED (IMC703) 31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED 32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE 62 - 2001 6.1) 33. DRYER VENT TO THE EXTERIOR - INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER OPENINGS: (IMC504.4, 401.52 AND 604.1) 34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS. CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE VAPOR BARRIER (R307) 35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE. ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL 36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE REQUIRED AT MIN 4" O.C. 37. 4 - MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING. FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED 38. WIND - WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING INSULATION DAM @ CEILING CHANGES 39. WEATHER - RESISTIVE BARRIER - i.e. BUILDING WRAP TABLE R703.4 40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO AT LEAST R - 3 41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE WEATHERED - STRIPPED AND INSULATED. 42. NEW WOOD - BURNING FIREPLACES WILL HAVE TIGHT - FITTING FLUE DAMPERS AND OUTDOOR COMBUSTION AIR. 43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6' ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4", WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL DEVICES. 44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH SLEEPING AREA OR BEDROOM. 45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi. 46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES. EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10". 47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL LOADS. 48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER - RESISTIVE BARRIER MUST LAP OVER THE ATTACHMENT FLANGE. 49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS 1/8" = 1'- 0" 1 Basement 1/8" = 1'- 0" 2 First Floor 1/8" = 1'- 0" 3 Second Floor 1/4" = 1'- 0" 4 Cross Section - Bedroom 3&4. Garage and Mudoom 3/8" = 1'- 0" 5 Detail - Great Room Fireplace 1 1/2" = 1'- 0" 6 Bracket #1 Detail ME C H PLUMBING LOCATION 2X 1 0 2 X 1 0 FL U S H 9 1 / 2 " L V L DR O P P E D B E A M DR O P P E D B E A M 18 " D E E P T R U S S E S 19 . 2 " O . C . B A S E S P A C I N G . DI M E N S I O N S O N T R U S S L A Y O U T A R E FR O M O U T S I D E O F F R A M I N G . LE F T E N D O F T R U S S E S A R E D E N O T E D ON T H E L A Y O U T W I T H A L I T T L E TR I A N G L E . L E F T E N D O F T R U S S HA S A L S O B E E N P A I N T E D . PL U M B I N G L O C A T I O N S A R E E S T I M A T E D . CO N T R A C T O R T O V E R I F Y P L U M B I N G LO C A T I O N S . D O N O T C U T T R U S S E S . IF Y O U H A V E A N Y Q U E S T I O N S O R CO N C E R N S , P L E A S E C A L L JO H N @ 6 5 1 - 6 8 8 - 3 6 0 9 OR E M A I L : JM I L L E R @ V I L L A U M E . C O M F 5 F 3 F 1 6 F13 F 1 5 F 1 7 F 1 4 F 1 4 F 4 F 6 F 7 F 7 F 6 F 6 F 4 F 2 F 2 F 1 F 1 F 1 F 1 F 1 F 1 F 1 F 1 F 1 F 1 0 F 1 1 F 1 1 F 1 1 F 1 1 F 1 1 F 1 2 F 1 2 F12 F12 F 1 0 F 8 F 8 F 9 F 9 F 9 F 9 F 9 F 9 F 9 F 8 F 8 3 0 - 0 0 - 0 0 1 8 - 0 0 - 0 0 4 8 - 0 0 - 0 0 4-00-00 10-00-0022-00-00 4-00-00 8-00-00 12 - 0 0 - 0 0 18 - 0 0 - 0 0 16 - 0 6 - 0 0 11 - 0 6 - 0 8 18 - 1 1 - 0 0 9 - 0 6 - 0 8 6 - 0 6 - 0 0 46 - 0 6 - 0 0 4 - 0 0 - 0 0 1- 0 6 - 0 0 2 - 0 0 - 0 0 8- 0 0 - 0 0 2 - 0 0 - 0 0 1 5 - 0 9 - 0 4 1 4 - 0 2 - 1 2 1 1 - 1 0 - 0 0 1 - 0 5 - 0 1 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 1 - 0 4 2 - 0 0 - 0 0 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1-07-03 Customer: Dakota County LumberJob Number: 304947-A Home Owner: SD / PERRONJob Name: Roof Site Address:Sales Rep: John Hummel City, ST, ZIP: MN Designer: John Miller2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 7/3/2018 Version: 8.2.2.241 ME C H P L U M B I N G W A L L P L U M B I N G W A L L P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N P L U M B I N G L O C A T I O N ST A I R H E A D E R FL U S H 9 1 / 2 " L V L DR O P P E D B E A M DR O P P E D B E A M D R O P P E D B E A M FL U S H 9 1 / 2 " L V L DR O P P E D B E A M F L U S H 3 P L Y 1 8 " L V L DR O P P E D B E A M WIN D O W H E A D E R A B O V E 2X 4 L E D G E R 2 X 4 L E D G E R 2 X 4 L E D G E R F L U S H 3 P L Y 1 8 " L V L 18" DEEP TRUSSES 19.2" O.C. BASE SPACING.DIMENSIONS ON TRUSS LAYOUT ARE FROM OUTSIDE OF FRAMING.LEFT END OF TRUSSES ARE DENOTED ON THE LAYOUT WITH A LITTLE TRIANGLE. LEFT END OF TRUSS HAS ALSO BEEN PAINTED.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBING LOCATIONS. DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE CALL JOHN @ 651-688-3609 OR EMAIL:JMILLER@VILLAUME.COM F F 6 F F 2 F F 1 8 F F 1 1 F F 1 9 F F 2 0 F F 5 F F 4 F F 4 F F 3 F F 3 F F 4 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 9 F F 9 F F 9 F F 9 F F 9 F F 9 F F 9 F F 1 0 F F 1 0 F F 1 0 F F 1 0 F F 1 0 F F 1 0 F F 1 0 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 8 F F 5 F F 7 F F 5 F F 5 F F 7 F F 1 5 F F 1 7 F F 1 6 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 3 F F 1 3 F F 1 4 F F 1 4 X 2 X 2 X 2 X 4 X 4 X 4 X 4 X 2 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 3 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 W2 W1 W1 W1 W1 W1 W1 W1 U 2 U 1 U 1 U 1 U 3 U 3 U 3 U 3 S 2 S 1 S 1 R 4 R 1 R1 R2 R2 R2 R2 R2 R2 R2 R1 R1 R3 Z2 Z1 Z1 Z1 Z1 Z2 S 3 S 3 S 3 S 3 Y2 Y1 Y1 Y1 MA 2 MA 2 MA 2 MA 2 MA 2 MA 2 V1 5 R V1 6 R V1 7 R V1 0 L V1 1 L V1 2 L V1 3 L V1 4 L P 3 P 3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P4 2- 0 6 - 0 0 1- 0 6 - 0 0 1 4 - 0 0 - 0 0 1 6 - 0 0 - 0 0 1 8 - 0 0 - 0 0 5 2 - 0 0 - 0 0 1-11-08 16-00-0828-00-006-00-00 14 - 0 0 - 0 0 2 - 0 0 - 0 0 8- 0 0 - 0 0 2 - 0 0 - 0 0 18 - 0 0 - 0 0 18 - 0 0 - 0 0 4 - 0 0 - 0 0 2 4 - 0 0 - 0 0 14 - 0 0 - 0 0 1 1 - 0 6 - 0 8 18 - 1 1 - 0 0 9 - 0 6 - 0 8 6 - 0 6 - 0 0 29-06-00 90 - 0 0 - 0 0 1 - 0 5 - 0 1 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 1 - 0 4 2 - 0 0 - 0 0 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 Customer: Dakota County LumberJob Number: 304947-A Home Owner: SD / PERRONJob Name: Roof Site Address:Sales Rep: John Hummel City, ST, ZIP: MN Designer: John Miller2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 7/3/2018 Version: 8.2.2.241 Job 304947-A Truss F1 Truss Type Floor Qty 9 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:12 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qesMD4JNErTWDKukUaDUcvVqysdg6k5drqpgzJz?pA1 Scale = 1:33.2 B1 BL1 BL1 T1 W3 W3 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 1.5x3 3x6 1.5x3 1.5x3 3x6 1.5x3 3x8 4x8 1.5x3 3x4 1.5x3 3x5 3x4 1.5x3 4x6 4x6 16-10-11 16-10-11 18-2-10 1-3-15 2-5-4 1-4-5 1-4-5 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.35 0.79 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.32 0.07 (loc) 12-13 12-13 10 l/defl >999 >681 n/a L/d 480 240 n/a PLATES MT20 Weight: 74 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 14 = 856/0-5-8 (min. 0-1-8) 10 = 856/0-2-8 (min. 0-1-8) Max Grav 14 = 856(LC 1) 10 = 856(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2317/0, 3-4=-2317/0, 4-5=-2810/0, 5-6=-2810/0, 6-7=-1558/0, 7-8=-1558/0 BOT CHORD 13-14=0/1404, 12-13=0/2766, 11-12=0/2390, 10-11=0/860 WEBS 2-14=-1588/0, 2-13=0/1043, 4-13=-512/0, 6-12=0/479, 6-11=-950/0, 8-11=0/971, 8-10=-1168/0 NOTES- 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss F2 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:14 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-m1_7emLdlTjETe26c?FyhKb?PgIYaZYvI8In2Bz?pA? Scale = 1:33.2 B1 BL1 BL1 T1 W3 W3 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 1.5x3 3x8 1.5x3 1.5x3 4x6 1.5x3 4x10 4x10 1.5x3 3x4 1.5x3 3x8 3x5 1.5x3 5x8 6x6 16-10-11 16-10-11 18-2-10 1-3-15 2-5-4 1-4-5 1-4-5 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.99 0.89 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.51 0.10 (loc) 12-13 12-13 10 l/defl >999 >422 n/a L/d 480 240 n/a PLATES MT20 Weight: 74 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF 1650F 1.5E(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 14 = 1162/0-5-8 (min. 0-1-8) 10 = 1181/0-2-8 (min. 0-1-8) Max Grav 14 = 1162(LC 1) 10 = 1181(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3451/0, 3-4=-3451/0, 4-5=-4384/0, 5-6=-4384/0, 6-17=-2242/0, 7-17=-2242/0, 7-8=-2242/0 BOT CHORD 13-14=0/1967, 12-13=0/4301, 11-12=0/3662, 10-11=0/1209 WEBS 2-14=-2228/0, 2-13=0/1693, 3-13=-304/0, 4-13=-971/0, 5-12=-405/0, 6-12=0/824, 6-11=-1620/0, 8-11=0/1437, 8-10=-1645/0 NOTES- 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 2) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-14=-8, 1-3=-88, 3-17=-163, 9-17=-88 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-14=-8, 1-3=-88, 3-17=-163, 9-17=-88 Job 304947-A Truss F3 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:16 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-jP6t3SMuH4zxiyCVjQHQnlgZCUBm2gWCmSnt54z?p9z Scale = 1:32.7 B1 BL1 BL1 T1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 31 32 3x4 3x5 1.5x5 3x4 18-2-10 18-2-10 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [16:0-2-0,Edge], [32:0-1-8,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.01 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 67 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 18-2-10. (lb) - Max Grav All reactions 250 lb or less at joint(s) 30, 16, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss F4 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:17 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-BcgFHoNW2O5oK6nhH7ofJzDbktPln0PM?6XRdWz?p9y Scale = 1:53.7 B1 BL1 BL1 T1 W3 W4 W5 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 24 23 22 21 20 19 18 17 16 25 26 3x6 FP3x6 3x6 FP 3x6 3x4 3x4 3x5 3x4 4x8 3x8 4x4 3x4 3x4 3x8 3x8 4x8 3x4 3x6 15-9-4 15-9-4 25-9-12 10-0-8 30-0-0 4-2-4 2-5-4 0-4-12 2-5-0 1-5-4 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [21:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.66 0.48 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.15 0.03 (loc) 22-23 22-23 16 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 121 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 24 = 590/0-5-8 (min. 0-1-8) 20 = 1759/0-5-8 (min. 0-1-8) 16 = 495/0-5-8 (min. 0-1-8) Max Grav 24 = 633(LC 3) 20 = 1759(LC 1) 16 = 563(LC 4) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1498/0, 3-4=-1498/0, 4-5=-1182/23, 5-6=-1182/23, 6-7=0/1353, 7-8=0/1353, 8-9=0/1733, 9-10=0/1737, 10-11=-921/285, 11-12=-921/285, 12-13=-1145/0, 13-14=-1145/0 BOT CHORD 23-24=0/989, 22-23=0/1542, 21-22=-414/356, 20-21=-1353/0, 19-20=-721/142, 18-19=-721/142, 17-18=-28/1232, 16-17=0/580 WEBS 2-24=-1118/0, 2-23=0/581, 4-22=-501/0, 6-22=0/1032, 6-21=-1500/0, 8-21=0/732, 8-20=-948/0, 12-18=-497/0, 10-18=0/1028, 10-20=-1493/0, 14-17=0/645, 14-16=-770/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F5 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:19 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7_n0hUPma?LWZPx4OYr7OOI4ShCRF1GfSQ0XiPz?p9w Scale = 1:54.0 B2 BL1 BL1 T1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 B1 T21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2425 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 51 52 3x6 FP 3x4 3x4 3x6 FP 30-0-0 30-0-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 26 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 105 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 30-0-0. (lb) - Max Grav All reactions 250 lb or less at joint(s) 26, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 35, 34, 33, 32, 31, 30, 29, 28, 27 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss F6 Truss Type Floor Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:21 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-3Nvm69Q06ccEoj4SWztbUpNHLVmZjqdxvkVenHz?p9u Scale = 1:56.2 B1 BL1 BL2 T1 W3 W6W4W5 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 23 22 21 20 19 18 17 27 28 29 3x6 FP3x6 4x6 3x6 FP 3x8 4x8 3x4 3x4 3x4 3x6 3x4 3x8 3x8 4x4 3x4 3x4 3x8 3x5 4x8 3x6 15-9-4 15-9-4 25-9-12 10-0-8 29-10-8 4-0-12 30-0-0 0-1-8 31-6-0 1-6-0 2-5-4 0-4-12 2-5-0 1-5-4 1-3-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [16:0-1-8,Edge], [23:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.69 0.55 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.15 0.03 (loc) 24-25 24-25 22 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 129 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 26 = 606/0-5-8 (min. 0-1-8) 18 = 1643/0-5-8 (min. 0-1-8) 22 = 1627/0-5-8 (min. 0-1-8) Max Grav 26 = 649(LC 5) 18 = 1711(LC 4) 22 = 1633(LC 3) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1555/0, 3-4=-1555/0, 4-5=-1296/0, 5-6=-1296/0, 6-7=0/1189, 7-8=0/1189, 8-9=0/1565, 9-10=0/1569, 10-11=-691/526, 11-12=-691/526, 12-13=-513/543, 13-14=-513/543, 14-15=0/980, 15-16=0/980 BOT CHORD 25-26=0/1018, 24-25=0/1628, 23-24=-278/498, 22-23=-1189/0, 21-22=-753/112, 20-21=-753/112, 19-20=-480/801, 18-19=-785/0 WEBS 2-26=-1151/0, 2-25=0/613, 4-24=-471/0, 6-24=0/1001, 6-23=-1469/0, 8-23=0/719, 8-22=-935/0, 16-18=-1355/0, 12-19=-340/0, 12-20=-267/0, 10-20=0/801, 10-22=-1266/0, 14-19=0/881, 14-18=-916/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 16=-889 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 16=-889 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-889 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-16=-88 Concentrated Loads (lb) Vert: 16=-889 5) 3rd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-88, 9-15=-24, 15-16=-88 Concentrated Loads (lb) Vert: 16=-889 6) 4th Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-889 7) 5th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-889 8) 6th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-16=-88 Concentrated Loads (lb) Vert: 16=-889 9) 7th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-88, 9-15=-24, 15-16=-88 Concentrated Loads (lb) Vert: 16=-889 10) 8th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-889 Job 304947-A Truss F7 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:23 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-0m1XXrSHeEsy21ErdOv3ZETcCISJBkyEN2_lrAz?p9s Scale = 1:56.4 B1 BL1 BL2 T1 W3 W6W4W5 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 23 22 21 20 19 18 17 27 28 29 3x6 FP3x6 3x4 3x6 FP 3x6 3x6 3x4 3x4 3x4 3x5 3x4 3x8 3x8 4x4 3x4 3x4 3x8 3x6 4x8 3x5 15-9-4 15-9-4 25-9-12 10-0-8 29-10-8 4-0-12 30-0-0 0-1-8 31-6-0 1-6-0 2-5-4 0-4-12 2-5-0 1-5-4 1-3-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [16:0-1-8,Edge], [23:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.73 0.53 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.15 0.03 (loc) 24-25 24-25 22 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 129 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 26 = 594/0-5-8 (min. 0-1-8) 18 = 862/0-5-8 (min. 0-1-8) 22 = 1723/0-5-8 (min. 0-1-8) Max Grav 26 = 638(LC 5) 18 = 930(LC 4) 22 = 1729(LC 3) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1514/0, 3-4=-1514/0, 4-5=-1213/0, 5-6=-1213/0, 6-7=0/1314, 7-8=0/1314, 8-9=0/1693, 9-10=0/1697, 10-11=-867/350, 11-12=-867/350, 12-13=-995/61, 13-14=-995/61, 14-15=0/257, 15-16=0/256 BOT CHORD 25-26=0/997, 24-25=0/1566, 23-24=-382/395, 22-23=-1314/0, 21-22=-729/136, 20-21=-729/136, 19-20=-152/1130, 18-19=-152/386 WEBS 2-26=-1127/0, 2-25=0/590, 4-24=-494/0, 6-24=0/1024, 6-23=-1492/0, 8-23=0/729, 8-22=-944/0, 16-18=-354/0, 12-20=-442/0, 10-20=0/974, 10-22=-1439/0, 14-19=0/708, 14-18=-794/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise 3) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 16=-192 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 16=-192 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-192 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-16=-88 Concentrated Loads (lb) Vert: 16=-192 5) 3rd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-88, 9-15=-24, 15-16=-88 Concentrated Loads (lb) Vert: 16=-192 6) 4th Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Standard Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-192 7) 5th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-192 8) 6th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-16=-88 Concentrated Loads (lb) Vert: 16=-192 9) 7th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-88, 9-15=-24, 15-16=-88 Concentrated Loads (lb) Vert: 16=-192 10) 8th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-9=-24, 9-15=-88, 15-16=-24 Concentrated Loads (lb) Vert: 16=-192 Job 304947-A Truss F8 Truss Type Floor Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:24 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-UybvlBTvPX_pfBp1B6QI5R?qWioYwBoOchjINcz?p9r Scale = 1:47.1 B1 BL1 BL1 T1 W5W2W4 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 21 20 19 18 17 16 15 14 22 23 3x6 FP 1.5x3 3x6 1.5x3 1.5x3 1.5x3 3x6 FP 3x6 1.5x3 3x4 3x6 3x4 3x6 1.5x3 3x4 4x8 3x4 3x4 3x8 1.5x3 3x6 4x4 3x4 4-11-6 4-11-6 15-6-6 10-7-0 25-9-2 10-2-12 2-2-6 2-5-4 0-4-12 2-5-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [17:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.57 0.47 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.14 0.02 (loc) 19-20 19-20 16 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 105 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 21 = 608/0-2-8 (min. 0-1-8) 14 = 282/0-5-8 (min. 0-1-8) 16 = 1547/0-5-8 (min. 0-1-8) Max Uplift 14 = -8(LC 3) Max Grav 21 = 626(LC 3) 14 = 384(LC 4) 16 = 1547(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1445/0, 3-4=-1445/0, 4-5=-1186/0, 5-6=-1186/0, 6-7=0/1018, 7-8=0/1018, 8-9=0/1384, 9-10=0/1388, 10-11=-581/297, 11-12=-581/297 BOT CHORD 20-21=0/903, 19-20=0/1517, 18-19=-99/389, 17-18=-99/389, 16-17=-1018/0, 15-16=-693/174, 14-15=-87/525 WEBS 12-14=-591/100, 10-15=0/674, 10-16=-1145/0, 2-20=0/619, 2-21=-1045/0, 4-19=-416/0, 6-19=0/948, 6-17=-1416/0, 8-17=0/697, 8-16=-935/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 21. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 14. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F9 Truss Type Floor Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:26 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-QLif9tU9x9EXvUzQJWTmBs48?WTMO4Lh3?CPSVz?p9p Scale = 1:47.1 B1 BL1 BL1 T2 W5W2W4 B2 T11 2 3 4 5 6 7 8 9 10 11 12 13 21 20 19 18 17 16 15 14 22 23 24 25 3x6 FP 1.5x3 3x6 1.5x3 1.5x3 1.5x3 3x6 FP 3x6 1.5x3 3x4 3x6 3x4 3x6 1.5x3 3x5 4x8 3x5 3x4 4x8 1.5x3 3x8 4x4 3x4 4-11-6 4-11-6 15-6-6 10-7-0 25-9-2 10-2-12 2-2-6 2-5-4 0-4-12 2-5-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [17:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.69 0.57 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.16 0.03 (loc) 19-20 19-20 16 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 105 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 21 = 650/0-2-8 (min. 0-1-8) 14 = 264/0-5-8 (min. 0-1-8) 16 = 1678/0-5-8 (min. 0-1-8) Max Uplift 14 = -26(LC 3) Max Grav 21 = 669(LC 3) 14 = 365(LC 4) 16 = 1678(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1596/0, 3-24=-1596/0, 4-24=-1596/0, 4-5=-1340/0, 5-6=-1340/0, 6-25=0/1095, 7-25=0/1095, 7-8=0/1095, 8-9=0/1517, 9-10=0/1520, 10-11=-514/364, 11-12=-514/364 BOT CHORD 20-21=0/974, 19-20=0/1729, 18-19=-52/436, 17-18=-52/436, 16-17=-1095/0, 15-16=-792/74, 14-15=-121/491 WEBS 12-14=-553/139, 12-15=-277/26, 10-15=0/712, 10-16=-1182/0, 2-20=0/710, 2-21=-1128/0, 4-19=-483/0, 6-19=0/1070, 6-17=-1557/0, 8-17=0/764, 8-16=-1071/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 21. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 26 lb uplift at joint 14. 4) Load case(s) 1, 2, 3, 4, 5, 6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-21=-8, 1-24=-88, 5-24=-112, 5-25=-88, 9-25=-112, 9-13=-88 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-21=-8, 1-24=-88, 5-24=-112, 5-25=-88, 9-25=-112, 9-13=-88 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-21=-8, 1-24=-88, 5-24=-112, 5-25=-88, 9-25=-112, 9-13=-24 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-21=-8, 1-24=-24, 5-24=-48, 5-25=-24, 9-25=-48, 9-13=-88 5) 3rd unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-21=-8, 1-24=-88, 5-24=-112, 5-25=-88, 9-25=-112, 9-13=-24 6) 4th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Standard Uniform Loads (plf) Vert: 14-21=-8, 1-24=-24, 5-24=-48, 5-25=-24, 9-25=-48, 9-13=-88 Job 304947-A Truss F10 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:28 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-MjqQaYWPSmUE8o7oQxVEGHAZiJ7ZszvzWJhWWNz?p9n Scale = 1:25.8 B1 BL2 T1 BL1 W1 W4 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 17 18 1.5x3 4x6 1.5x3 6x6 4x8 1.5x3 4x6 3x4 3x4 1.5x3 3x6 3x4 4x4 3x4 0-4-0 0-4-0 3-4-4 3-0-4 14-2-0 10-9-12 0-5-12 2-5-4 0-6-0 0-1-8 1- 6 - 0 0- 9 - 8 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [9:Edge,0-1-8], [10:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.36 0.66 0.59 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.02 (loc) 11-12 11-12 9 l/defl >999 >918 n/a L/d 480 240 n/a PLATES MT20 Weight: 60 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9 = 802/0-5-8 (min. 0-1-8) 16 = 742/0-3-8 (min. 0-1-8) Max Grav 9 = 802(LC 1) 16 = 742(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-373/0, 2-3=-1421/0, 3-17=-1421/0, 4-17=-1421/0, 4-5=-2015/0, 5-6=-2015/0, 6-7=-430/0, 1-16=-742/0 BOT CHORD 12-13=0/373, 11-12=0/1966, 10-11=0/1482, 9-10=0/430 WEBS 2-12=0/1190, 2-13=-758/0, 1-13=0/854, 4-12=-622/0, 5-11=-279/0, 6-11=0/609, 6-10=-1200/0, 7-10=0/619, 7-9=-967/0 NOTES- 1) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 2) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 9-14=-8, 1-17=-88, 17-18=-112, 8-18=-88 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 9-14=-8, 1-17=-88, 17-18=-112, 8-18=-88 Job 304947-A Truss F11 Truss Type FLOOR Qty 5 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:29 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qwOoouW2D3c5myi?_f0ToVilkjUtbQE7lzR33qz?p9m Scale = 1:25.8 B1 BL2 T1 BL1 W1 W4 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 1.5x3 4x6 1.5x3 6x6 4x8 1.5x3 4x6 3x5 3x4 1.5x3 3x5 3x4 4x4 3x4 0-4-0 0-4-0 3-4-4 3-0-4 14-2-0 10-9-12 0-5-12 2-5-4 0-6-0 0-1-8 1- 6 - 0 0- 9 - 8 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [9:Edge,0-1-8], [10:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-10-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.28 0.59 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.18 0.02 (loc) 11-12 11-12 9 l/defl >999 >953 n/a L/d 480 240 n/a PLATES MT20 Weight: 60 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9 = 759/0-5-8 (min. 0-1-8) 16 = 764/0-3-8 (min. 0-1-8) Max Grav 9 = 759(LC 1) 16 = 764(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-386/0, 2-3=-1426/0, 3-4=-1426/0, 4-5=-1918/0, 5-6=-1918/0, 6-7=-406/0, 1-16=-764/0 BOT CHORD 12-13=0/386, 11-12=0/1900, 10-11=0/1395, 9-10=0/406 WEBS 3-12=-260/0, 2-12=0/1180, 2-13=-783/0, 1-13=0/884, 4-12=-541/0, 5-11=-250/0, 6-11=0/597, 6-10=-1129/0, 7-10=0/591, 7-9=-911/0 NOTES- 1) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F12 Truss Type Floor Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:31 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-nIWYDaYIlhsp?FrN542xuwo?vX7h3IqQDHwA7iz?p9k Scale = 1:40.2 B1 BL1 BL1 T1 W2 W4 B2 T21 2 3 4 5 6 7 8 9 10 11 12 20 19 18 17 16 15 14 13 21 22 3x12 MT18HS FP 1.5x3 4x6 1.5x3 1.5x3 1.5x3 3x6 FP 3x5 1.5x3 3x4 1.5x3 4x8 4x8 5x5 3x4 3x4 1.5x3 4x8 4x8 5x5 3x4 4x6 11-2-4 11-2-4 22-0-0 10-9-12 0-10-8 2-5-4 0-6-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [13:Edge,0-1-8], [14:0-1-8,Edge], [19:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.62 0.76 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.35 -0.62 0.11 (loc) 16 16-18 13 l/defl >744 >422 n/a L/d 480 240 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20%F, 11% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF 1650F 1.5E(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 20 = 1038/0-5-8 (min. 0-1-8) 13 = 1038/0-5-8 (min. 0-1-8) Max Grav 20 = 1038(LC 1) 13 = 1038(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-803/0, 3-4=-3352/0, 4-5=-3352/0, 5-6=-4156/0, 6-7=-4156/0, 7-8=-4156/0, 8-9=-3221/0, 9-10=-3221/0, 10-11=-543/0 BOT CHORD 19-20=0/803, 18-19=0/2281, 17-18=0/3955, 16-17=0/3955, 15-16=0/3890, 14-15=0/2085, 13-14=0/543 WEBS 5-18=-689/0, 3-18=0/1222, 3-19=-1688/0, 2-19=0/850, 2-20=-1312/0, 8-16=0/303, 8-15=-763/0, 10-15=0/1297, 10-14=-1760/0, 11-14=0/891, 11-13=-1218/0 NOTES- 1) All plates are MT20 plates unless otherwise indicated. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss F13 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:32 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-FU4wQwZwW__gdPQafnaAQ7KIAweTovUZRxfjf9z?p9j Scale = 1:39.4 B1 BL1 BL1 T2 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 B2 T11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 39 40 3x4 3x6 FP 3x4 3x6 FP 22-0-0 22-0-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 20 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 78 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 22-0-0. (lb) - Max Grav All reactions 250 lb or less at joint(s) 38, 20, 37, 36, 35, 34, 33, 32, 31, 29, 28, 27, 26, 25, 24, 23, 22, 21 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss F14 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:34 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-BtBhrcaA2cEOsjaynCceVYQcvkJYGpbsvF8qk1z?p9h Scale = 1:12.3 B1 BL1 W1 T1 W2 W3 W4 1 2 3 4 7 6 5 8 9 1.5x3 1.5x3 1.5x3 3x4 1.5x3 3x4 3x6 3x4 3x4 5-7-8 1-6-0 1-6-0 1-7-8 0-1-8 4-7-8 3-0-0 5-9-0 1-1-8 5-11-0 0-2-0 1-3-0 1-5-4 2-5-4 0-1-8 0-2-0 1- 6 - 0 1- 4 - 8 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.25 0.11 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.03 0.00 (loc) 6 5-6 4 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 27 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4 = 170/0-1-7 (min. 0-1-8) 6 = 357/0-5-8 (min. 0-1-8) Max Grav 4 = 187(LC 4) 6 = 357(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F15 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:35 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-f3l32ybopvMFUt98Kv7t2mypP8gE?GD?7vuOGTz?p9g Scale = 1:19.5 B1 BL1 W1 T1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 19 3x4 9-11-12 9-11-12 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.01 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 9-11-12. (lb) - Max Grav All reactions 250 lb or less at joint(s) 18, 10, 17, 16, 15, 14, 13, 12, 11 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F16 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:36 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7GJRGIcRaDV661kLude6bzV_3Y0DkjS9MZdxowz?p9f Scale = 1:16.7 B1 BL1 W1 T1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 3x4 3x6 3x4 8-5-8 8-5-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.08 0.03 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 8-5-8. (lb) - Max Grav All reactions 250 lb or less at joint(s) 15, 9, 14, 13, 12, 11, 10 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss F17 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:38 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-3eRBhzdh6qlqLKuj02hagOaKXLhqCdxSqt62toz?p9d Scale = 1:9.4 B1 BL1 W1 W1W1 T1 ST1 ST1 1 2 3 4 8 7 6 5 9 3x4 3x4 1.5x3 1.5x3 3x4 1.5x3 1.5x3 1.5x3 1.5x3 4-3-0 4-3-0 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.08 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 4-3-0. (lb) - Max Grav All reactions 250 lb or less at joint(s) 8, 5, 7, 6 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF1 Truss Type Floor Qty 11 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:39 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-Yr?auJeJt8thzUTwZlCpCc7R8lr?xymb2XsbPFz?p9c Scale = 1:33.2 B1 BL1 BL1 T1 W3 W3 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 1.5x3 3x6 1.5x3 1.5x3 3x6 1.5x3 3x8 4x8 1.5x3 3x4 1.5x3 3x5 3x4 1.5x3 4x6 4x6 16-10-11 16-10-11 18-2-10 1-3-15 2-5-4 1-4-5 1-4-5 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.35 0.79 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.32 0.07 (loc) 12-13 12-13 10 l/defl >999 >681 n/a L/d 480 240 n/a PLATES MT20 Weight: 74 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 14 = 856/0-5-8 (min. 0-1-8) 10 = 856/0-2-8 (min. 0-1-8) Max Grav 14 = 856(LC 1) 10 = 856(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2317/0, 3-4=-2317/0, 4-5=-2810/0, 5-6=-2810/0, 6-7=-1558/0, 7-8=-1558/0 BOT CHORD 13-14=0/1404, 12-13=0/2766, 11-12=0/2390, 10-11=0/860 WEBS 2-14=-1588/0, 2-13=0/1043, 4-13=-512/0, 6-12=0/479, 6-11=-950/0, 8-11=0/971, 8-10=-1168/0 NOTES- 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss FF2 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:41 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-UD6KJ?gZPl7OCocIhAEHH1CruZjdP_iuWrLiU7z?p9a Scale = 1:32.6 B1 BL1 BL1 T1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 31 32 3x4 3x4 18-2-10 18-2-10 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.01 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 65 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 18-2-10. (lb) - Max Grav All reactions 250 lb or less at joint(s) 30, 16, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss FF3 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:42 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-yQgiWLhB93FFqyBVFtlWqElsVyyV8Kj1kV4F0az?p9Z Scale = 1:57.3 B1 BL1 BL2 T1 W2 W4 W5 W6 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 23 22 21 20 19 18 17 27 28 29 3x6 FP 3x4 3x6 FP 3x8 3x4 3x8 3x4 3x4 3x6 3x4 3x8 3x6 4x4 3x4 3x8 4x8 3x4 3x6 3x4 3x6 2-0-0 2-0-0 2-1-8 0-1-8 17-9-4 15-7-12 22-9-12 5-0-8 32-0-0 9-2-4 1-9-0 2-5-4 0-4-12 2-5-0 1-5-4 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [21:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.72 0.49 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.14 0.02 (loc) 23-24 23-24 17 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 131 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 25 = 980/0-5-8 (min. 0-1-8) 20 = 1712/0-5-8 (min. 0-1-8) 17 = 502/0-3-8 (min. 0-1-8) Max Grav 25 = 1024(LC 3) 20 = 1723(LC 4) 17 = 570(LC 5) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/327, 2-3=0/329, 3-4=-1327/0, 4-5=-1327/0, 5-6=-1121/103, 6-7=-1121/103, 7-8=0/1307, 8-9=0/1307, 9-10=0/1674, 10-11=0/1678, 11-12=-969/247, 12-13=-969/247, 13-14=-1167/0, 14-15=-1167/0 BOT CHORD 24-25=-79/765, 23-24=0/1426, 22-23=-426/348, 21-22=-426/348, 20-21=-1307/0, 19-20=-672/204, 18-19=-0/1267, 17-18=0/588 WEBS 1-25=-400/0, 3-25=-1141/0, 3-24=0/665, 5-23=-437/0, 7-23=0/971, 7-21=-1439/0, 9-21=0/702, 9-20=-915/0, 11-19=0/1016, 11-20=-1481/0, 13-19=-485/0, 15-18=0/661, 15-17=-781/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise 3) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 1=-160 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 1=-160 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-160 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-16=-88 Concentrated Loads (lb) Vert: 1=-160 5) 3rd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-88, 2-10=-24, 10-16=-88 Concentrated Loads (lb) Vert: 1=-160 6) 4th Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Standard Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-160 7) 5th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-160 8) 6th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-16=-88 Concentrated Loads (lb) Vert: 1=-160 9) 7th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-88, 2-10=-24, 10-16=-88 Concentrated Loads (lb) Vert: 1=-160 10) 8th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-160 Job 304947-A Truss FF4 Truss Type Floor Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:44 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-uooTx1iShgVz3FLtMIn_vfqAsmdycBLKCpZM5Sz?p9X Scale = 1:57.0 B1 BL1 BL2 T2 W2 W4 W5 W6 B2 T11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 23 22 21 20 19 18 17 27 28 29 3x6 FP 4x8 3x6 FP 3x8 3x4 4x10 3x4 3x8 4x8 3x4 3x8 3x5 4x4 3x4 3x8 4x8 3x4 3x6 3x5 3x6 2-0-0 2-0-0 2-1-8 0-1-8 17-9-4 15-7-12 22-9-12 5-0-8 32-0-0 9-2-4 1-9-0 2-5-4 0-4-12 2-5-0 1-5-4 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [21:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.86 0.49 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.13 -0.02 (loc) 23-24 18-19 20 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 131 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 25 = 2360/0-5-8 (min. 0-1-10) 20 = 1498/0-5-8 (min. 0-1-8) 17 = 536/0-3-8 (min. 0-1-8) Max Grav 25 = 2404(LC 3) 20 = 1652(LC 4) 17 = 604(LC 5) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/2018, 2-3=0/2020, 3-4=-981/967, 4-5=-981/967, 5-6=-992/489, 6-7=-992/489, 7-8=0/1219, 8-9=0/1219, 9-10=0/1559, 10-11=0/1563, 11-12=-1193/172, 12-13=-1193/172, 13-14=-1267/0, 14-15=-1267/0 BOT CHORD 24-25=-1445/310, 23-24=-673/1188, 22-23=-485/328, 21-22=-485/328, 20-21=-1219/0, 19-20=-577/490, 18-19=0/1430, 17-18=0/627 WEBS 1-25=-2468/0, 3-25=-1510/0, 3-24=0/1037, 5-24=-503/0, 5-23=-313/211, 7-23=-4/847, 7-21=-1315/0, 9-21=0/643, 9-20=-850/0, 11-19=0/993, 11-20=-1458/0, 13-19=-462/0, 15-18=0/731, 15-17=-832/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 1=-1360 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-16=-88 Concentrated Loads (lb) Vert: 1=-1360 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-1360 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-16=-88 Concentrated Loads (lb) Vert: 1=-560 5) 3rd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Standard Vert: 17-26=-8, 1-2=-88, 2-10=-24, 10-16=-88 Concentrated Loads (lb) Vert: 1=-1360 6) 4th Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-560 7) 5th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-1360 8) 6th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-16=-88 Concentrated Loads (lb) Vert: 1=-560 9) 7th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-88, 2-10=-24, 10-16=-88 Concentrated Loads (lb) Vert: 1=-1360 10) 8th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 17-26=-8, 1-2=-24, 2-10=-88, 10-16=-24 Concentrated Loads (lb) Vert: 1=-560 Job 304947-A Truss FF5 Truss Type Floor Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:46 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qBwDMikiDIlhIZVGUjqS_4wVKaKk45qdf72T9Lz?p9V Scale = 1:32.4 B1 BL1 W1 T1 W2 W4 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 1.5x3 1.5x3 1.5x3 4x8 3x4 4x6 4x10 3x4 4x6 4x8 1.5x3 3x4 1.5x3 3x5 3x4 3x4 3x4 2-0-0 2-0-0 2-1-8 0-1-8 17-10-12 15-9-4 1-9-0 2-5-4 0-4-12 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [10:Edge,0-1-8], [11:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.86 0.40 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.13 -0.02 (loc) 12-13 12-13 10 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 76 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 10 = 568/0-4-4 (min. 0-1-8) 14 = 2479/0-5-8 (min. 0-1-11) Max Grav 10 = 576(LC 4) 14 = 2479(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/2018, 2-3=0/2019, 3-4=-567/753, 4-5=-567/753, 5-6=-1292/64, 6-7=-1292/64, 7-8=-270/0 BOT CHORD 13-14=-1337/0, 12-13=-354/1131, 11-12=0/985, 10-11=0/270 WEBS 1-14=-2468/0, 3-14=-1666/0, 3-13=0/1192, 5-13=-658/0, 5-12=0/332, 7-12=-125/351, 7-11=-816/0, 8-11=0/438, 8-10=-690/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Load case(s) 1, 2, 3, 4, 5, 6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-9=-88 Concentrated Loads (lb) Vert: 1=-1360 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-9=-88 Concentrated Loads (lb) Vert: 1=-1360 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-2=-88, 2-9=-24 Concentrated Loads (lb) Vert: 1=-1360 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-2=-24, 2-9=-88 Concentrated Loads (lb) Vert: 1=-1360 5) 3rd unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-2=-88, 2-9=-24 Concentrated Loads (lb) Vert: 1=-1360 6) 4th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-2=-24, 2-9=-88 Concentrated Loads (lb) Vert: 1=-1360 Job 304947-A Truss FF6 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:47 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-JNUba2kK_btYwj4S1RLhXISjDzdsphLmumo0hnz?p9U Scale = 1:57.4 B1 BL1 BL2 T2 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 B2 T11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 53 54 55 56 4x6 3x6 FP 3x5 5x5 3x5 3x6 FP 2-0-0 2-0-0 2-1-8 0-1-8 32-0-0 29-10-8 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [27:Edge,0-1-8], [53:0-1-8,0-0-8] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.66 0.60 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 27 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 110 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 30-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 27=-108(LC 3), 49=-215(LC 3) Max Grav All reactions 250 lb or less at joint(s) 27, 49, 48, 47, 46, 45, 44, 43, 42, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29 except 50=595(LC 1), 28=326(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-50=-362/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 27 and 215 lb uplift at joint 49. 6) Non Standard bearing condition. Review required. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF7 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:49 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-FmbM_kmaWD7G90Dr9sN9cjX9bnJPHVb3L4H7mgz?p9S Scale = 1:25.9 B1 BL1 W1 T1 W2 W4 1 2 3 4 5 6 7 11 10 9 8 12 1.5x3 3x6 1.5x3 3x4 3x6 3x8 1.5x3 3x6 3x4 1.5x3 3x6 3x4 4-2-4 4-2-4 14-4-4 10-2-0 1-5-4 2-5-4 2-5-0 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.28 0.53 0.43 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.14 0.03 (loc) 9-10 9-10 8 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 59 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 11 = 671/0-5-8 (min. 0-1-8) 8 = 677/0-4-4 (min. 0-1-8) Max Grav 11 = 671(LC 1) 8 = 677(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1463/0, 3-4=-1463/0, 4-5=-1634/0, 5-6=-1634/0 BOT CHORD 10-11=0/702, 9-10=0/1750, 8-9=0/1054 WEBS 2-10=0/868, 2-11=-933/0, 4-10=-327/0, 6-9=0/662, 6-8=-1198/0 NOTES- 1) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF8 Truss Type Floor Qty 11 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:50 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-jy9kC4nDHWF7nAo1jZuO9w4GyBge0xEDak0gI6z?p9R Scale = 1:47.0 B1 BL1 BL2 T1 W5W2W4 B2 T21 2 3 4 5 6 7 8 9 10 11 12 13 21 20 19 18 17 16 15 14 22 23 24 3x6 FP 1.5x3 3x6 1.5x3 1.5x5 1.5x5 3x4 3x6 FP 3x6 1.5x3 3x4 4x8 3x4 1.5x3 3x6 3x4 3x6 3x4 3x4 3x8 1.5x3 3x6 4x4 3x4 4-11-6 4-11-6 15-6-6 10-7-0 25-9-2 10-2-12 2-2-6 2-5-4 0-4-12 2-3-8 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [13:0-1-8,Edge], [17:0-1-8,Edge], [23:0-1-8,0-0-12], [24:0-1-8,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.57 0.47 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.14 0.02 (loc) 18-20 18-20 16 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 106 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 21 = 608/0-2-8 (min. 0-1-8) 16 = 1542/0-3-8 (min. 0-1-8) 14 = 280/0-5-8 (min. 0-1-8) Max Uplift 14 = -10(LC 3) Max Grav 21 = 626(LC 3) 16 = 1542(LC 1) 14 = 383(LC 4) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1445/0, 3-4=-1445/0, 4-5=-1186/0, 5-6=-1186/0, 6-7=0/1009, 7-8=0/1374, 8-9=0/1378, 9-10=-570/295, 10-11=-570/295, 11-12=-570/295 BOT CHORD 20-21=0/903, 19-20=0/1517, 18-19=0/1517, 17-18=-89/389, 16-17=-1009/0, 15-16=-690/179, 14-15=-86/498 WEBS 9-16=-1139/0, 9-15=0/660, 12-14=-573/98, 2-20=0/618, 2-21=-1045/0, 4-18=-415/0, 6-18=0/946, 6-17=-1414/0, 7-17=0/695, 7-16=-934/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 21. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint 14. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF9 Truss Type FLOOR Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:52 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-fLHUdmoTp8Wr0UyQq_xsEL9g0_LSUq9V22VnN_z?p9P Scale = 1:25.4 B1 BL2 T1 BL1 W1 W4 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 1.5x3 6x6 1.5x3 6x6 4x8 1.5x3 3x6 3x5 3x4 1.5x3 3x6 3x4 4x4 3x5 0-4-0 0-4-0 3-4-8 3-0-8 13-11-6 10-6-14 0-6-0 2-5-4 0-3-2 0-1-8 1- 6 - 0 0- 9 - 8 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [2:0-1-8,Edge], [9:Edge,0-1-8], [10:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-10-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.27 0.57 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.17 0.02 (loc) 11-12 11-12 9 l/defl >999 >973 n/a L/d 480 240 n/a PLATES MT20 Weight: 60 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9 = 747/0-2-10 (min. 0-1-8) 16 = 751/0-3-8 (min. 0-1-8) Max Grav 9 = 747(LC 1) 16 = 751(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-390/0, 2-3=-1403/0, 3-4=-1403/0, 4-5=-1844/0, 5-6=-1844/0, 6-7=-280/0, 1-16=-751/0 BOT CHORD 12-13=0/390, 11-12=0/1851, 10-11=0/1295, 9-10=0/280 WEBS 3-12=-260/0, 2-12=0/1150, 2-13=-768/0, 1-13=0/872, 4-12=-511/0, 5-11=-251/0, 6-11=0/627, 6-10=-1158/0, 7-10=0/614, 7-9=-918/0 NOTES- 1) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 9. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF10 Truss Type Floor Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:53 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7Xrsq6p5aReheeXcOhS5nZirTOeCDHIfGiFLvRz?p9O Scale = 1:31.6 B1 BL2 T1 BL1 W1 W4 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 1.5x3 6x6 1.5x3 4x6 3x6 1.5x3 3x4 1.5x3 4x8 3x4 1.5x3 3x8 3x6 4x4 3x5 0-4-0 0-4-0 6-8-4 6-4-4 17-3-2 10-6-14 1-4-8 2-5-4 0-3-2 0-1-8 1- 6 - 0 0- 9 - 8 1- 6 - 0 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [10:Edge,0-1-8], [11:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.29 0.73 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.27 0.03 (loc) 12-13 12-13 10 l/defl >999 >753 n/a L/d 480 240 n/a PLATES MT20 Weight: 71 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 10 = 810/0-2-10 (min. 0-1-8) 17 = 814/0-3-8 (min. 0-1-8) Max Grav 10 = 810(LC 1) 17 = 814(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-874/0, 2-3=-874/0, 3-4=-2430/0, 4-5=-2430/0, 5-6=-2235/0, 6-7=-2235/0, 7-8=-297/0, 1-17=-814/0 BOT CHORD 13-14=0/1856, 12-13=0/2533, 11-12=0/1468, 10-11=0/297 WEBS 3-13=0/655, 3-14=-1120/0, 1-14=0/1164, 5-12=-340/0, 7-12=0/875, 7-11=-1337/0, 8-11=0/695, 8-10=-970/0 NOTES- 1) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF11 Truss Type Floor Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:54 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-bjPF2RqjLlmYGo6oyPzKJmFuBoy9yfcoVM_uRtz?p9N Scale: 3/8"=1' B1 W1 BL2 T2 BL1 W4W4W2 W4 W4 W4 W4 W5W2T1 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 17 16 18 3x6 7x12 1.5x3 1.5x3 6x12 5x8 1.5x3 4x8 6x12 3x5 3x4 1.5x3 6x8 4x10 3x5 0-2-0 0-2-0 6-8-4 6-6-4 17-3-2 10-6-14 1-1-8 2-5-4 0-3-2 0-1-8 1- 6 - 0 0- 9 - 8 0- 1 - 8 1- 6 - 0 Plate Offsets (X,Y)-- [10:0-4-6,Edge], [12:0-2-0,Edge], [13:0-3-12,Edge], [18:0-0-12,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.81 0.88 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.48 0.03 (loc) 12-13 12-13 10 l/defl >999 >424 n/a L/d 480 240 n/a PLATES MT20 Weight: 93 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) *Except* T2: 2x4 SPF 1650F 1.5E(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 10 = 1650/0-2-12 (min. 0-1-8) 18 = 1610/0-3-8 (min. 0-1-8) Max Grav 10 = 1650(LC 1) 18 = 1610(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1738/0, 2-3=-1748/0, 3-4=-5040/0, 4-5=-5040/0, 5-6=-4648/0, 6-7=-4648/0, 7-8=-546/0 BOT CHORD 13-14=0/3850, 12-13=0/5302, 11-12=0/3054, 10-11=0/568 WEBS 4-13=-460/0, 3-13=0/1344, 3-14=-2370/0, 2-14=-492/0, 1-14=0/2300, 5-13=-296/0, 5-12=-739/0, 6-12=-459/0, 7-12=0/1801, 7-11=-2832/0, 8-11=0/1186, 8-10=-1768/0, 1-18=-1636/0, 17-18=0/356 NOTES- 1) Bearing at joint(s) 18 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 3) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-9=-188 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-15=-8, 1-9=-188 Job 304947-A Truss FF12 Truss Type Floor Qty 8 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:56 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-Y6X?S7rzsM0GV5GB3q?oOBKLoce2Qej5ygT?Wmz?p9L Scale = 1:33.2 B1 BL1 BL1 T1 W2W2 W4 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 1.5x3 3x6 1.5x3 1.5x3 3x6 1.5x3 4x8 1.5x3 3x4 1.5x3 3x5 3x4 1.5x3 4x6 4x6 3x8 13-2-4 13-2-4 18-2-10 5-0-6 1-5-4 1-5-4 2-5-4 2-3-6 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.35 0.79 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.32 0.07 (loc) 11-12 11-12 10 l/defl >999 >683 n/a L/d 480 240 n/a PLATES MT20 Weight: 74 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 14 = 856/0-5-8 (min. 0-1-8) 10 = 856/0-2-10 (min. 0-1-8) Max Grav 14 = 856(LC 1) 10 = 856(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1623/0, 3-4=-1623/0, 4-5=-2821/0, 5-6=-2821/0, 6-7=-2274/0, 7-8=-2274/0 BOT CHORD 13-14=0/901, 12-13=0/2428, 11-12=0/2750, 10-11=0/1331 WEBS 6-11=-543/0, 4-12=0/448, 4-13=-919/0, 2-13=0/979, 2-14=-1197/0, 8-11=0/1077, 8-10=-1528/0 NOTES- 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss FF13 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:58 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-UVeltptEO_G_kPQZBF1GUcPaLPKGuROOQ_y6aez?p9J Scale = 1:33.2 B1 BL1 BL1 T1 W2 W2 W3 W3 W5W5W4 W5 W6 W3 W3W2 W2 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 1.5x3 4x8 1.5x3 1.5x3 4x8 1.5x3 5x8 1.5x3 4x6 5x12 1.5x3 5x8 4x8 3x6 1.5x3 3x8 3x6 4x12 3-2-4 3-2-4 6-2-12 3-0-8 13-2-4 6-11-8 18-2-10 5-0-6 1-5-4 1-5-4 1-5-2 1-5-2 1-9-4 2-5-4 2-3-6 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [11:Edge,0-1-8], [16:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.80 0.80 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.54 0.10 (loc) 12-13 12-13 11 l/defl >781 >402 n/a L/d 480 240 n/a PLATES MT20 Weight: 86 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E(flat) BOT CHORD 2x4 SPF 2100F 1.8E(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 16 = 1688/0-5-8 (min. 0-1-8) 11 = 1284/0-5-8 (min. 0-1-8) Max Grav 16 = 1688(LC 1) 11 = 1284(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3451/0, 3-4=-3451/0, 4-5=-6134/0, 5-6=-5886/0, 6-7=-5886/0, 7-8=-3797/0, 8-9=-3797/0 BOT CHORD 15-16=0/1846, 14-15=0/4882, 13-14=0/6214, 12-13=0/5049, 11-12=0/2079 WEBS 5-14=-1173/0, 2-16=-2456/0, 2-15=0/2177, 4-15=-1948/0, 4-14=0/1721, 7-12=-1430/0, 7-13=0/955, 5-13=-401/0, 9-12=0/1961, 9-11=-2390/0 NOTES- 1) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-16=-8, 1-10=-88 Concentrated Loads (lb) Vert: 5=-1260 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-16=-8, 1-10=-88 Concentrated Loads (lb) Vert: 5=-1260 Job 304947-A Truss FF14 Truss Type Floor Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:00:59 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-yhC859us9HOrMZ_mkyZV0qym9pgldxXXfeif64z?p9I Scale = 1:33.2 B1 BL1 BL2 T1 W2 W6W6W5 W6 W7W3 W4 W4 W4 W4 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 1.5x3 1.5x3 1.5x3 3x4 1.5x3 3x6 1.5x3 4x10 1.5x3 5x8 3x4 6x6 6x6 5x8 3x4 1.5x3 3x5 3x6 4x8 5x8 1-11-8 1-11-8 2-1-0 0-1-8 2-3-8 0-2-8 3-2-4 0-10-12 6-2-12 3-0-8 13-2-4 6-11-8 18-2-10 5-0-6 1-8-8 0-11-0 1-5-2 1-5-2 1-9-4 2-5-4 2-3-6 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [3:0-1-8,Edge], [14:0-3-0,Edge], [15:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.73 0.79 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.36 0.08 (loc) 12-13 12-13 11 l/defl >999 >532 n/a L/d 480 240 n/a PLATES MT20 Weight: 84 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF 1650F 1.5E(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 11 = 1026/0-2-10 (min. 0-1-8) 16 = 2407/0-5-8 (min. 0-1-10) Max Grav 11 = 1033(LC 4) 16 = 2407(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/716, 2-3=0/715, 3-4=-720/0, 4-5=-3953/0, 5-6=-4079/0, 6-7=-4079/0, 7-8=-2902/0, 8-9=-2902/0 BOT CHORD 15-16=0/720, 14-15=0/2429, 13-14=0/4051, 12-13=0/3696, 11-12=0/1639 WEBS 3-15=0/1584, 5-14=-1432/0, 1-16=-887/0, 7-12=-907/0, 7-13=0/514, 5-13=-281/46, 9-12=0/1441, 9-11=-1883/0, 3-16=-2158/0, 4-15=-2340/0, 4-14=0/2106 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. 3) Load case(s) 1, 2, 3, 4, 5, 6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-10=-88 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-10=-88 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 3) 1st Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-2=-88, 2-10=-24 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 4) 2nd Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-2=-24, 2-10=-88 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 5) 3rd unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-2=-88, 2-10=-24 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 6) 4th unbalanced Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-8, 1-2=-24, 2-10=-88 Concentrated Loads (lb) Vert: 17=-200 1=-260 5=-1260 Job 304947-A Truss FF15 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:01 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-u4KuWrv6hveZbs88sNbz5F19ZdXI5yTq6yBmBzz?p9G Scale = 1:32.3 B1 BL1 BL2 T1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1W2 W3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 29 30 31 3x4 3x4 3x4 3x4 3x4 3x8 2-0-0 2-0-0 18-2-10 16-2-10 1-9-0 1-4-4 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.48 0.08 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 27 26-27 15 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 69 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 16-2-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 26=-748(LC 3) Max Grav All reactions 250 lb or less at joint(s) 15, 15, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16 except 27=2166(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/862, 2-3=0/858 WEBS 3-26=0/750, 2-27=-763/0, 1-27=-1058/0, 3-27=-1148/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 748 lb uplift at joint 26. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 15-28=-10, 1-14=-110 Concentrated Loads (lb) Vert: 1=-526 2=-526 Job 304947-A Truss FF16 Truss Type Floor Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:02 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-MGuGjBwkSCmQD0jLQ46CeSaI_0eXqHw_LcwJjPz?p9F Scale = 1:33.2 B1 BL1 BL1 T1 W3 W7W2 W2 W3 W4 W6W5 T1W2 W2 W3 W7W3 W4 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 1.5x3 4x10 1.5x3 4x10 3x6 3x6 5x12 1.5x5 4x12 1.5x5 5x16 3x6 6x12 6x8 6x12 6x8 3-2-4 3-2-4 8-2-12 5-0-8 13-2-4 4-11-8 18-2-10 5-0-6 1-5-4 1-5-4 2-5-4 2-5-0 2-4-0 2-3-6 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [3:0-3-0,Edge], [6:0-3-8,Edge], [7:0-3-0,Edge], [10:Edge,0-1-8], [14:Edge,0-1-8], [15:0-1-8,0-0-9], [16:0-1-8,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.63 0.97 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.56 0.13 (loc) 11-12 11-12 10 l/defl >723 >382 n/a L/d 480 240 n/a PLATES MT20 Weight: 110 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF 2100F 1.8E(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 14 = 1818/0-5-8 (min. 0-1-8) 10 = 1646/0-2-10 (min. 0-1-8) Max Grav 14 = 1818(LC 1) 10 = 1646(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3999/0, 3-4=-3991/0, 4-5=-8835/0, 5-6=-8835/0, 6-7=-5277/0, 7-8=-5262/0 BOT CHORD 13-14=0/2073, 12-13=0/6576, 11-12=0/7283, 10-11=0/2827 WEBS 7-11=-254/0, 5-12=-1961/0, 8-11=0/2771, 8-10=-3213/0, 2-14=-2703/0, 2-13=0/2525, 4-13=-2932/0, 4-12=0/2541, 6-11=-2252/0, 6-12=0/1759 NOTES- 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 2) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-14=-8, 1-9=-88 Concentrated Loads (lb) Vert: 5=-1751 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-14=-8, 1-9=-88 Concentrated Loads (lb) Vert: 5=-1751 Job 304947-A Truss FF17 Truss Type Floor Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:04 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-Je?18sy?_q08SKtjXV8gjtfkJqVqILKGowPQoIz?p9D Scale = 1:18.4 B1 BL1 BL2 T1 W3 1 2 3 4 5 8 7 6 9 10 11 1.5x3 1.5x3 1.5x3 1.5x3 3x6 1.5x3 3x4 3x4 1.5x3 3x5 3x4 10-2-10 10-2-10 2-5-4 2-3-6 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.25 0.28 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.08 0.01 (loc) 7 7-8 6 l/defl >999 >999 n/a L/d 480 240 n/a PLATES MT20 Weight: 42 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6 = 470/0-5-8 (min. 0-1-8) 8 = 475/0-4-13 (min. 0-1-8) Max Grav 6 = 470(LC 1) 8 = 475(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-899/0, 3-4=-899/0 BOT CHORD 7-8=0/676, 6-7=0/657 WEBS 2-8=-772/0, 2-7=0/253, 4-7=0/275, 4-6=-753/0 NOTES- 1) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job 304947-A Truss FF18 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:06 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-F17nZYzFWRGrie16fwB8oIl6UeFEmItZGEuXsAz?p9B Scale = 1:16.7 B1 BL1 BL2 T1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 3x4 3x6 3x4 8-5-8 8-5-8 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.08 0.03 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 8-5-8. (lb) - Max Grav All reactions 250 lb or less at joint(s) 15, 9, 14, 13, 12, 11, 10 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss FF19 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:08 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-BQFX_E?V22XZxxAUmLDcujqS8Rw?EBPsjYNdx3z?p99 Scale: 3/4"=1' B1 BL1 BL2 T1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 3x4 3x4 3x4 8-0-0 8-0-0 0-1-8 0-1-8 1- 6 - 0 1- 6 - 0 LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.01 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 8-0-0. (lb) - Max Grav All reactions 250 lb or less at joint(s) 14, 8, 13, 12, 11, 10, 9 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job 304947-A Truss FF20 Truss Type Floor Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 10:01:10 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7oNIOw0lZgnHBFKtumF4z8vogFcPi5w9Brsk?yz?p97 Scale = 1:9.4 B1 BL1 W1 W1W1W1 T1 ST1 ST1 1 2 3 4 8 7 6 5 9 3x4 3x5 1.5x3 1.5x3 3x5 1.5x3 1.5x3 1.5x3 1.5x3 4-1-8 4-1-8 0-1-8 1- 6 - 0 1- 6 - 0 Plate Offsets (X,Y)-- [4:0-2-0,Edge], [5:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 15.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-R 0.07 0.01 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20%F, 11% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2(flat) BOT CHORD 2x4 SPF No.2(flat) WEBS 2x4 SPF Stud(flat) OTHERS 2x4 SPF Stud(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 4-1-8. (lb) - Max Grav All reactions 250 lb or less at joint(s) 8, 5, 7, 6 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 3) Gable studs spaced at 1-4-0 oc. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard DR O P P E D B E A M WIN D O W H E A D E R A B O V E 2X 4 L E D G E R 2 X 4 L E D G E R 2 X 4 L E D G E R F L U S H 3 P L Y 1 8 " L V L 5 ' - 1 5 / 8 " W A L L H E I G H T 5 ' - 1 5 / 8 " W A L L H E I G H T THE Y TRUSSES ARE DESIGNED TO BEAR ON A 2X6 PLATE SET ON TOP OF THE SUB-FLOOR AT THE EXTERIOR WALL.DIMENSIONS ON TRUSS LAYOUT ARE FROM OUTSIDE OF FRAMING.THE LEFT END OF EACH TRUSS IS DENOTED WITH A LITTLE TRIANGE.IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE CALL JOHN @ 651-688-3609 OR EMAIL: JMILLER@VILLAUME.COM X 2 X 2 X 2 X 4 X 4 X 4 X 4 X 2 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 3 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 M A 1 W2 W1 W1 W1 W1 W1 W1 W1 U 2 U 1 U 1 U 1 U 3 U 3 U 3 U 3 S 2 S 1 S 1 R 4 R 1 R1 R2 R2 R2 R2 R2 R2 R2 R1 R1 R3 Z2 Z1 Z1 Z1 Z1 Z2 S 3 S 3 S 3 S 3 Y2 Y1 Y1 Y1 MA 2 MA 2 MA 2 MA 2 MA 2 MA 2 V1 5 R V1 6 R V1 7 R V1 0 L V1 1 L V1 2 L V1 3 L V1 4 L P 3 P 3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P4 2- 0 6 - 0 0 1- 0 6 - 0 0 1 4 - 0 0 - 0 0 1 6 - 0 0 - 0 0 1 8 - 0 0 - 0 0 5 2 - 0 0 - 0 0 1-11-08 16-00-0828-00-006-00-00 14 - 0 0 - 0 0 2 - 0 0 - 0 0 8- 0 0 - 0 0 2 - 0 0 - 0 0 18 - 0 0 - 0 0 18 - 0 0 - 0 0 4 - 0 0 - 0 0 2 4 - 0 0 - 0 0 14 - 0 0 - 0 0 1 1 - 0 6 - 0 8 18 - 1 1 - 0 0 9 - 0 6 - 0 8 6 - 0 6 - 0 0 29-06-00 90 - 0 0 - 0 0 D1 E2 E1 E1 E1 E1 E3 E4 E4 E4 E5 H2 H1 H3 A 3 A 2 A 1 A 1 A 1 A 4 A 5 A 6 A 6 A 6 A 6 J1 K 1 K1 A 6 A 6 A 6 A 7 A 7 G2 G1 G1 G1 G1 G3 G3 G4 L1 M 2 M 1 M 1 M 1 M 1 A 8 B 1 B 1 B 1 B 2 C 2 C 1 C 1 C 1 C 3 C 3 N 1 V1 V2 V4 V5 V6 V1 V2 V3 V3 V 9 V7 V8 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 5- 0 8 1- 0 8 - 0 8 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 Customer: Dakota County LumberJob Number: 304947-A Home Owner: SD / PERRONJob Name: Roof Site Address:Sales Rep: John Hummel City, ST, ZIP: MN Designer: John Miller2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 7/3/2018 Version: 8.2.2.241 Job 304947-A Truss A1 Truss Type Roof Special Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:05 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-xA71rC?Tc4WLgrDqxl8co1LAxLyvEXvWs5PfSVz?nKy Scale = 1:71.1 W1 T1 T2 T3 T4 B1 W2 W3 W4 W5 W6 W7 B2 HW2 1 2 3 4 13 5 6 11 10 9 8 7 14 12 2x4 4x6 4x6 4x6 6x6 3x6 4x6 4x8 2x3 6x6 5-7-7 5-7-7 13-0-0 7-4-9 19-2-14 6-2-14 28-0-0 8-9-2 5-7-7 5-7-7 13-0-0 7-4-9 19-2-14 6-2-14 23-6-5 4-3-6 28-0-0 4-5-11 29-0-0 1-0-0 3- 6 - 1 4 4- 1 0 - 1 3 12 - 2 - 3 0- 6 - 4 3- 6 - 1 4 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [2:0-3-4,0-2-4], [5:0-1-3,0-0-9], [5:0-7-0,0-1-3], [5:Edge,0-3-4], [9:0-4-0,0-1-12], [10:0-2-0,0-1-12], [11:0-2-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.99 0.91 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.47 0.05 (loc) 7-14 7-14 5 l/defl >999 >712 n/a L/d 240 180 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T2,T4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W1: 2x4 SPF No.2 W3,W7: 2x3 SPF Stud WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-5-11 max.): 1-2. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-9, 4-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 11 = 1447/Mechanical 5 = 1534/0-5-8 (min. 0-2-6) Max Horz 11 = -281(LC 6) Max Uplift 11 = -59(LC 8) 5 = -83(LC 9) Max Grav 11 = 1447(LC 1) 5 = 1534(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-11=-1396/82, 1-2=-1981/107, 2-3=-1564/169, 3-4=-1531/164, 4-13=-2358/93, 5-13=-953/0 BOT CHORD 9-10=-117/2014, 8-9=-20/1968, 7-8=-20/1968, 7-14=-18/1972, 12-14=-13/781 WEBS 1-10=-98/2275, 2-10=-1056/136, WEBS 1-10=-98/2275, 2-10=-1056/136, 2-9=-1251/175, 3-9=-81/1440, 4-9=-1361/221, 4-7=0/304, 5-12=-905/48, 13-14=-517/222, 12-13=-883/27, 5-14=-35/914 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss A2 Truss Type Roof Special Girder Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:08 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-Llo9TD1Mv?uwXJyPctiJQgzhtY0wRuczY3dK2qz?nKv Scale = 1:71.6 W1 T1 T2 T3 T4 B2 W2 W5 W4 W6 W3 W7 B1 HW2 1 2 3 4 13 5 6 11 10 9 8 7 14 12 15 16 2x4 4x6 4x6 4x6 6x6 3x6 4x6 4x8 4x6 4x8 2x3 NAILED NAILED 1-9-10 1-9-10 2-9-12 1-0-2 5-7-7 2-9-12 13-0-0 7-4-9 19-2-14 6-2-14 28-0-0 8-9-2 1-9-10 1-9-10 2-9-12 1-0-2 5-7-7 2-9-12 13-0-0 7-4-9 19-2-14 6-2-14 28-0-0 8-9-2 29-0-0 1-0-0 3- 6 - 1 4 4- 1 0 - 1 3 12 - 2 - 3 0- 6 - 4 3- 6 - 1 4 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [2:0-3-4,0-2-4], [5:0-0-0,0-1-3], [5:0-1-5,0-7-11], [9:0-4-0,0-1-12], [10:0-2-0,0-1-12], [11:0-2-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.95 0.76 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.45 0.04 (loc) 7-14 7-14 5 l/defl >999 >736 n/a L/d 240 180 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T2,T4: 2x4 DF 2400F 2.0E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x3 SPF No.2 *Except* W1: 2x4 SPF No.2 W3,W7: 2x3 SPF Stud WEDGE Right: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (3-5-6 max.): 1-2. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-9, 4-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 11 = 1462/Mechanical 5 = 1535/0-5-8 (min. 0-2-7) Max Horz 11 = -281(LC 6) Max Uplift 11 = -131(LC 8) 5 = -88(LC 9) Max Grav 11 = 1462(LC 1) 5 = 1535(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-11=-1400/131, 1-15=-1987/147, 2-15=-1987/147, 2-3=-1565/180, 3-4=-1532/172, 4-13=-2350/106, 5-13=-1161/0 BOT CHORD 11-16=-165/259, 10-16=-165/259, 9-10=-151/2020, 8-9=-29/1970, 7-8=-29/1970, 7-14=-27/1975, 12-14=-14/884 BOT CHORD 11-16=-165/259, 10-16=-165/259, 9-10=-151/2020, 8-9=-29/1970, 7-8=-29/1970, 7-14=-27/1975, 12-14=-14/884 WEBS 1-10=-133/2280, 3-9=-96/1442, 2-9=-1257/206, 4-9=-1363/226, 2-10=-1054/144, 4-7=0/302, 5-12=-940/58, 13-14=-371/169, 12-13=-908/34, 5-14=-34/960 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 11=131. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe-nails per NDS guidlines. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-3=-84, 3-4=-84, 4-6=-84, 11-12=-20 Concentrated Loads (lb) Vert: 16=-16(B) Job 304947-A Truss A3 Truss Type Roof Special Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:11 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-mKUI5F3ECwGUOmhzH?F02IbPgmDleO4PE1s_f9z?nKs Scale = 1:67.4 T1 T2 T3 B1 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST6 ST5 ST4 ST3 ST8 ST9 ST10 ST11 ST12 ST13 HW1 HW2B2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 38 37 36 35 34 33 32 3130 29 28 27 26 25 24 23 22 4x4 3x6 3x6 3x6 3x4 3x8 24-10-7 24-10-7 9-10-7 9-10-7 16-1-5 6-2-14 24-10-7 8-9-2 25-10-7 1-0-0 0- 8 - 0 4- 1 0 - 1 3 12 - 2 - 3 0- 6 - 4 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-0-7,0-0-6], [1:0-0-14,0-2-12], [20:0-0-0,0-0-15], [20:0-2-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.08 0.05 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.01 (loc) 21 21 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST7,ST6,ST5: 2x3 SPF No.2 WEDGE Left: 2x4 SPF No.2, Right: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-33, 7-34, 6-35, 9-31, 10-30 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 24-10-7. (lb) - Max Horz 1=-250(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 34, 35, 36, 37, 38, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 20 except 39=-138(LC 8), 1=-142(LC 6) Max Grav All reactions 250 lb or less at joint(s) 33, 34, 35, 36, 37, 38, 39, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 20 except 1=286(LC 8) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-367/231, 19-20=-256/84 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 34, 35, 36, 37, 38, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 20 except (jt=lb) 39=138, 1=142. LOAD CASE(S) Standard Job 304947-A Truss A4 Truss Type Roof Special Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:13 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-ijc2Wx5UkXWCd4qMPQHU7jgX4Zgs68WihKL4k2z?nKq Scale = 1:70.5 T1 T2 T3 T4 B2 W6 W7 W8 W1 W2 HW2B1 W5 W3 W4 1 2 3 4 5 14 6 7 12 11 10 9 8 15 1316 17 4x4 5x5 4x6 6x6 4x6 6x6 4x8 2x4 2x4 4x8 2x4 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 28-0-0 8-9-2 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 28-0-0 8-9-2 29-0-0 1-0-0 1- 4 - 2 7- 1 - 6 4- 1 0 - 1 3 12 - 2 - 3 0- 6 - 4 8.00 12 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-1-8], [6:0-1-3,0-0-9], [6:0-7-0,0-1-3], [6:Edge,0-3-4], [10:0-4-0,0-1-8], [11:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.98 0.90 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.50 0.04 (loc) 10-11 10-11 6 l/defl >999 >662 n/a L/d 240 180 n/a PLATES MT20 Weight: 115 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W8,W2,W3: 2x3 SPF Stud W1: 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12. WEBS 1 Row at midpt 5-10, 3-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 1534/0-5-8 (min. 0-2-6) 12 = 1447/Mechanical Max Horz 12 = -255(LC 6) Max Uplift 6 = -83(LC 9) 12 = -52(LC 8) Max Grav 6 = 1534(LC 1) 12 = 1447(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1738/68, 2-3=-1761/166, 3-4=-1448/193, 4-5=-1534/176, 5-14=-2359/107, 6-14=-956/0, 1-12=-1422/60 BOT CHORD 11-12=-170/267, 11-16=-73/1253, 16-17=-73/1253, 10-17=-73/1253, BOT CHORD 11-12=-170/267, 11-16=-73/1253, 16-17=-73/1253, 10-17=-73/1253, 9-10=-36/1969, 8-9=-36/1969, 8-15=-34/1974, 13-15=-13/781 WEBS 4-10=-140/1556, 5-10=-1369/227, 5-8=0/293, 1-11=-5/1337, 3-10=-717/209, 2-11=-390/162, 3-11=-86/320, 6-13=-905/48, 14-15=-510/222, 13-14=-884/28, 6-15=-36/913 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 12. LOAD CASE(S) Standard Job 304947-A Truss A5 Truss Type Roof Special Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:15 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-e5jpxd7lG8mwsO_lWrKyC8lu6NQQa3d?9eqBowz?nKo Scale = 1:69.1 T1 T2 T3 T4 B2W2 W5 W6 W7 W8 W1 W10 W9 W3 W4 B1 1 2 3 4 5 6 12 11 10 9 8 713 14 4x4 4x6 4x4 5x5 4x6 3x6 3x4 4x8 4x8 3x5 2x4 2x3 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 25-6-14 6-4-0 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 25-6-14 6-4-0 1- 4 - 2 7- 1 - 6 4- 1 0 - 1 3 12 - 2 - 3 1- 8 - 1 3 8.00 12 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-0,0-1-8], [4:0-1-12,0-2-0], [5:0-2-4,0-2-8], [6:Edge,0-1-8], [8:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.95 0.70 0.77 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.45 0.04 (loc) 10-11 10-11 7 l/defl >999 >672 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W5,W6,W7,W4: 2x3 SPF No.2 W1,W10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12. WEBS 1 Row at midpt 3-10, 5-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 7 = 1315/Mechanical 12 = 1315/0-5-8 (min. 0-2-1) Max Horz 12 = -246(LC 4) Max Uplift 7 = -47(LC 9) 12 = -49(LC 8) Max Grav 7 = 1315(LC 1) 12 = 1315(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1566/59, 2-3=-1590/163, 3-4=-1231/182, 4-5=-1311/170, 5-6=-1657/96, 1-12=-1288/58, 6-7=-1251/80 BOT CHORD 11-12=-209/257, 11-13=-75/1102, 13-14=-75/1102, 10-14=-75/1102, 9-10=-31/1384, 8-9=-31/1384 WEBS 1-11=0/1191, 3-10=-676/209, WEBS 1-11=0/1191, 3-10=-676/209, 4-10=-131/1217, 5-10=-817/191, 6-8=-40/1271, 2-11=-391/162, 3-11=-87/354 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 12. LOAD CASE(S) Standard Job 304947-A Truss A6 Truss Type Roof Special Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:17 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-bUrZMI8?om0e6h87eGMQHZrEhA6z2zDIcyJItpz?nKm Scale = 1:69.4 T1 T2 T3 T4 B2W2 W5 W6 W7 W8 W1 W10 W9 W3 W4 B11 2 3 4 5 6 7 13 12 11 10 9 814 15 4x6 4x4 5x5 4x6 3x6 3x4 4x8 3x5 4x8 3x5 2x4 2x3 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 25-6-14 6-4-0 -2-0-0 2-0-0 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 19-2-14 6-2-14 25-6-14 6-4-0 1- 4 - 2 7- 1 - 6 4- 1 0 - 1 3 12 - 2 - 3 1- 8 - 1 3 8.00 12 14.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-12], [5:0-1-12,0-2-0], [6:0-2-4,0-2-8], [7:Edge,0-1-8], [9:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.94 0.70 0.76 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.45 0.04 (loc) 11-12 11-12 8 l/defl >999 >676 n/a L/d 240 180 n/a PLATES MT20 Weight: 117 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W5,W6,W7,W4: 2x3 SPF No.2 W1,W10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 4-11, 6-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 8 = 1307/Mechanical 13 = 1503/0-5-8 (min. 0-2-6) Max Horz 13 = -256(LC 6) Max Uplift 8 = -47(LC 9) 13 = -88(LC 8) Max Grav 8 = 1307(LC 1) 13 = 1503(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1526/60, 3-4=-1529/153, 4-5=-1220/182, 5-6=-1299/168, 6-7=-1646/94, 2-13=-1477/97, 7-8=-1243/80 BOT CHORD 12-14=-73/1087, 14-15=-73/1087, 11-15=-73/1087, 10-11=-29/1373, 9-10=-29/1373 WEBS 2-12=0/1232, 4-11=-660/206, WEBS 2-12=0/1232, 4-11=-660/206, 5-11=-129/1200, 6-11=-814/191, 7-9=-38/1260, 3-12=-355/151, 4-12=-78/308 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 13. LOAD CASE(S) Standard Job 304947-A Truss A7 Truss Type Roof Special Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:19 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-XtzKn_AFJNGML?IWlhOuN_wgJ_nSWsSa4GoPxhz?nKk Scale = 1:69.4 T1 T2 T3 T4 B1 W3 W4 W5 W6 W7 W8 W9 W1 W2 W11 W10 B21 2 3 4 5 6 7 8 14 13 12 11 10 915 16 17 4x6 4x4 4x4 2x4 3x6 2x3 4x8 4x8 2x3 3x5 2x4 4x8 4x4 4-5-3 4-5-3 13-0-0 8-6-13 19-4-12 6-4-12 25-6-14 6-2-2 -2-0-0 2-0-0 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 15-7-4 2-7-4 19-4-12 3-9-8 25-6-14 6-2-2 1- 4 - 2 7- 1 - 6 9- 1 - 1 2 12 - 2 - 3 4- 1 1 - 1 4 8.00 12 14.00 12 5.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-12], [5:0-1-12,0-2-0], [6:0-2-0,0-1-12], [8:0-1-8,0-1-12], [9:0-2-0,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.55 0.70 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.41 0.03 (loc) 12-13 12-13 9 l/defl >999 >735 n/a L/d 240 180 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W3,W9,W2: 2x3 SPF Stud W1,W11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14. WEBS 1 Row at midpt 4-12, 6-12, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 14 = 1503/0-5-8 (min. 0-2-6) 9 = 1307/Mechanical Max Horz 14 = -260(LC 6) Max Uplift 14 = -87(LC 8) 9 = -64(LC 9) Max Grav 14 = 1503(LC 1) 9 = 1307(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1525/48, 3-4=-1527/151, 4-5=-1224/160, 5-6=-1120/194, 6-7=-1026/128, 7-8=-1026/91, 2-14=-1478/96, 8-9=-1249/93 BOT CHORD 13-15=-80/1138, 15-16=-80/1138, 12-16=-80/1138, 11-12=-26/905, 11-17=-26/905, 10-17=-26/905 WEBS 3-13=-352/150, 4-13=-77/283, WEBS 3-13=-352/150, 4-13=-77/283, 4-12=-673/210, 5-12=-167/1315, 6-12=-605/178, 7-10=-506/163, 2-13=0/1231, 8-10=-32/1068 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 9. LOAD CASE(S) Standard Job 304947-A Truss A8 Truss Type Roof Special Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:21 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-TF54CgBWr_X4aJRut6RMSP?zJoRY_metXaHW0az?nKi Scale = 1:71.5 T1 T2 T3 T4 B1 W3 W4 W5 W6 W7 W8 W1 W11 W10 B2W2 W9 1 2 3 4 5 6 7 8 14 13 12 11 10 915 16 17 4x6 4x4 4x4 3x5 2x4 3x6 2x3 4x8 4x8 3x5 3x4 4x8 2x3 8-7-14 8-7-14 15-7-4 6-11-5 19-4-12 3-9-8 21-3-13 1-11-1 27-2-14 5-11-1 -2-0-0 2-0-0 4-3-8 4-3-8 8-7-14 4-4-6 13-0-0 4-4-2 15-7-4 2-7-4 19-4-12 3-9-8 21-3-13 1-11-1 27-2-14 5-11-1 1- 4 - 2 7- 1 - 6 9- 1 - 1 2 12 - 2 - 3 4- 3 - 9 8.00 12 14.00 12 5.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-12], [5:0-1-8,0-2-0], [6:0-2-0,0-1-12], [8:Edge,0-1-0], [9:Edge,0-1-8], [12:0-4-0,0-1-8], [13:0-3-4,0-2-0], [14:0-2-0,0-0-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.71 0.79 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.39 0.04 (loc) 10-12 12-13 9 l/defl >999 >825 n/a L/d 240 180 n/a PLATES MT20 Weight: 132 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W4,W5,W6,W7,W8: 2x3 SPF No.2 W1: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14. WEBS 1 Row at midpt 4-12, 6-12, 6-10, 8-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 14 = 1591/0-5-8 (min. 0-2-8) 9 = 1396/Mechanical Max Horz 14 = -263(LC 6) Max Uplift 14 = -89(LC 8) 9 = -71(LC 9) Max Grav 14 = 1591(LC 1) 9 = 1396(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1636/52, 3-4=-1637/156, 4-5=-1374/173, 5-6=-1302/199, 6-7=-1243/152, 7-8=-1191/77, 2-14=-1563/100, 8-9=-1349/95 BOT CHORD 13-14=-159/253, 13-15=-80/1256, 15-16=-80/1256, 12-16=-80/1256, 11-12=-16/1065, 11-17=-16/1065, 10-17=-16/1065 BOT CHORD 13-14=-159/253, 13-15=-80/1256, 15-16=-80/1256, 12-16=-80/1256, 11-12=-16/1065, 11-17=-16/1065, 10-17=-16/1065 WEBS 3-13=-351/149, 4-13=-80/258, 4-12=-696/212, 5-12=-188/1571, 6-12=-820/216, 8-10=-44/1253, 2-13=0/1320, 7-10=-576/186 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 9. LOAD CASE(S) Standard Job 304947-A Truss B1 Truss Type Roof Special Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:23 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-PeCqdMDmNcnnqcbH_XTqXq5EBbAySiaA?umc4Sz?nKg Scale = 1:69.1 T1 T2 T3 B1 W6W1 W2 W8 W7 B2 W3 W4 W5 1 2 3 4 5 10 9 8 7 611 5x5 4x4 4x4 3x4 2x4 3x6 2x3 3x8 3x8 2x4 2-7-2 2-7-2 9-6-8 6-11-5 15-3-1 5-8-9 21-2-2 5-11-1 6-11-4 6-11-4 9-6-8 2-7-4 15-3-1 5-8-9 21-2-2 5-11-1 4- 1 - 1 9- 1 - 1 2 12 - 2 - 3 4- 3 - 9 14.00 12 5.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-4], [2:0-2-0,0-1-12], [3:0-2-0,0-1-12], [5:0-2-0,0-1-0], [7:0-2-8,0-1-8], [9:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 1.00 0.60 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.36 0.01 (loc) 7-9 7-9 6 l/defl >999 >700 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W6,W8,W7: 2x3 SPF Stud W1: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 10 = 1088/Mechanical 6 = 1088/Mechanical Max Horz 10 = -284(LC 4) Max Uplift 10 = -57(LC 9) 6 = -60(LC 9) Max Grav 10 = 1088(LC 1) 6 = 1088(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-902/131, 2-3=-724/151, 3-4=-944/141, 4-5=-892/59, 1-10=-1030/90, 5-6=-1042/83 BOT CHORD 9-10=-135/273, 8-9=-26/667, 8-11=-26/667, 7-11=-26/667 WEBS 4-7=-576/187, 1-9=-42/471, 5-7=-31/919, 2-9=-113/664, 3-9=-695/198, 3-7=-107/296 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. LOAD CASE(S) Standard Job 304947-A Truss B2 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:25 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-M0Kb11E0vD1V3wlg6yVIcFAahPsOwe9TSCFj9Lz?nKe Scale = 1:69.1 T1 T2 T3 B1 W2 W3 W4 W7W1 W11 W9 W5 B2 W6 W8 W10 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 1 2 3 4 5 10 9 8 7 6 12 14 13 11 29 5x5 4x4 4x4 3x4 2x4 3x6 3x8 3x8 3x4 3x5 3x5 9-6-8 9-6-8 15-3-1 5-8-9 21-2-2 5-11-1 6-11-4 6-11-4 9-6-8 2-7-4 15-3-1 5-8-9 21-2-2 5-11-1 4- 1 - 1 9- 1 - 1 2 12 - 2 - 3 4- 3 - 9 14.00 12 5.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-4], [2:0-2-0,0-1-12], [3:0-2-0,0-1-12], [5:0-2-0,0-1-0], [6:Edge,0-2-8], [9:0-2-0,0-1-8], [13:0-0-6,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 1.00 0.60 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.36 0.01 (loc) 7-9 7-9 6 l/defl >999 >699 n/a L/d 240 180 n/a PLATES MT20 Weight: 132 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W2,W3,W4,W5: 2x3 SPF No.2 W7,W11,W9: 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9 JOINTS 1 Brace at Jt(s): 11, 12, 13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 10 = 1088/Mechanical 6 = 1088/0-2-6 (min. 0-1-11) Max Horz 10 = -284(LC 4) Max Uplift 10 = -57(LC 9) 6 = -60(LC 9) Max Grav 10 = 1088(LC 1) 6 = 1088(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-902/131, 2-3=-724/151, 3-4=-937/140, 4-5=-882/58, 1-10=-1030/90, 6-14=-1040/82, 5-14=-1027/83 BOT CHORD 9-10=-135/273, 8-9=-26/667, 8-29=-26/667, 7-29=-26/667 WEBS 1-9=-42/471, 2-9=-113/664, WEBS 1-9=-42/471, 2-9=-113/664, 3-9=-695/198, 7-12=-575/187, 4-12=-577/187, 7-13=-31/899, 5-13=-30/904, 3-11=-105/288, 7-11=-109/302 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. LOAD CASE(S) Standard Job 304947-A Truss C1 Truss Type Roof Special Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:26 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qDuzFNFegX9Mh4Ksgf0X9Sjmrp7Xf1_chs_Ghnz?nKd Scale = 1:73.9 T1 T2 T3 T4 B1 W1 W2 W3 W4 W5 W6HW1 HW2B21 2 15 3 4 5 6 7 198 9 14 16 13 12 11 10 201817 4x6 4x6 6x6 4x10 4x6 3x6 3x4 2x3 5x8 2x3 7x8 9-1-7 9-1-7 15-0-0 5-10-9 21-5-14 6-5-14 29-6-0 8-0-2 -1-6-0 1-6-0 4-7-15 4-7-15 9-1-7 4-5-7 15-0-0 5-10-9 21-5-14 6-5-14 29-6-0 8-0-2 30-8-0 1-2-0 0- 9 - 2 5- 3 - 1 3 4- 7 - 5 12 - 2 - 3 0- 7 - 4 6.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-5-3,Edge], [8:Edge,0-3-4], [8:0-5-0,0-0-3], [8:0-0-3,0-0-1], [12:0-4-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.91 0.86 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.36 0.09 (loc) 12-13 12-13 8 l/defl >999 >988 n/a L/d 240 180 n/a PLATES MT20 Weight: 119 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3,T4: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W3,W4,W5: 2x3 SPF No.2 WEDGE Right: 2x6 SPF 1650F 1.5E SLIDER Left 2x6 SPF 1650F 1.5E 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12, 7-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2 = 1661/0-5-8 (min. 0-2-10) 8 = 1631/0-5-8 (min. 0-2-9) Max Horz 2 = 198(LC 7) Max Uplift 2 = -95(LC 8) 8 = -85(LC 9) Max Grav 2 = 1661(LC 1) 8 = 1631(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-908/0, 3-15=-783/0, 3-4=-2468/130, 4-5=-2234/114, 5-6=-1666/188, 6-7=-1694/185, 7-19=-2535/112, 8-19=-754/0 BOT CHORD 14-16=-229/1009, 13-16=-201/2116, 12-13=-122/1944, 11-12=-45/2128, 10-11=-45/2128, 10-20=-43/2132, 18-20=-20/722 BOT CHORD 14-16=-229/1009, 13-16=-201/2116, 12-13=-122/1944, 11-12=-45/2128, 10-11=-45/2128, 10-20=-43/2132, 18-20=-20/722 WEBS 5-13=0/304, 5-12=-1277/199, 6-12=-110/1721, 7-12=-1387/220, 7-10=0/287, 2-14=-1000/0, 16-17=0/254, 15-17=-38/586, 2-17=0/549, 14-17=-903/142, 3-17=-1990/267, 8-18=-880/35, 19-20=-568/216, 18-19=-1028/32, 8-20=-30/963 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. LOAD CASE(S) Standard Job 304947-A Truss C2 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:30 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-i_7U5lI9klfoAhddvV5UJItRlQUKbnDCcUzUqYz?nKZ Scale = 1:73.9 T1 T2 T3 T4 B2 W3 W4HW1 HW2B1 W2 W2 W1 W1 ST12 ST11 ST10 ST11 ST9 ST8 ST7ST6ST5ST4ST3ST2 ST1 ST10 ST11 ST13 ST14 ST15 ST16 ST17 ST18 ST19ST20ST21 ST22 1 2 69 34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 662021 6870 34 33 32 31 30 29 28 27 26 25 2423 22 6765 35 42 39 4536 37 38 71 3x6 5x5 6x6 5x8 6x6 3x4 3x8 4x4 4x4 4x4 2x4 3-0-8 3- 1 - 0 5- 4 - 1 4 9-1-7 9-1-7 12-5-5 3-3-14 13-5-12 1-0-7 15-0-0 1-6-4 16-6-4 1-6-4 21-5-14 4-11-10 29-6-0 8-0-2 -1-6-0 1-6-0 4-7-15 4-7-15 9-1-7 4-5-7 13-5-12 4-4-5 15-0-0 1-6-4 16-2-12 1-2-12 16-6-4 0-3-8 21-5-14 4-11-10 29-6-0 8-0-2 30-8-0 1-2-0 0- 9 - 2 5- 3 - 1 3 4- 7 - 5 12 - 2 - 3 0- 7 - 4 6.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-4-3,0-0-3], [16:0-3-0,Edge], [20:Edge,0-2-9], [20:0-5-0,0-0-3], [20:0-0-3,0-0-1], [24:0-0-0,0-1-12], [24:0-4-0,0-0-4], [35:0-0-0,0-1-12], [35:0-2-0,0-0-12], [36:0-0-0,0-1-12], [42:0-1-4,0-0-0], [44:0-1-8,0-0-8], [45:0-1-4,0-0-0], [46:0-1-4,0-0-0], [47:0-1-8,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.98 0.93 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.65 0.02 (loc) 22-23 22-23 20 l/defl >552 >315 n/a L/d 240 180 n/a PLATES MT20 Weight: 187 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2: 2x4 SPF 1650F 1.5E WEBS 2x4 SPF 1650F 1.5E *Except* W3,W4: 2x3 SPF Stud W1: 2x3 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST9,ST13: 2x3 SPF No.2 WEDGE Right: 2x4 SPF No.2 SLIDER Left 2x6 SPF 1650F 1.5E 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 25-26,23-25. WEBS 1 Row at midpt 19-23, 13-26 JOINTS 1 Brace at Jt(s): 35, 36, 37, 38 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-5-5 except (jt=length) 20=0-5-8, 26=0-3-8, 26=0-3-8. (lb) - Max Horz 2= 198(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 20, 2, 28, 29, 30, 31, 32, 33, 26 except 27=-218(LC 20), 34=-153(LC 20) Max Grav All reactions 250 lb or less at joint(s) 27, 30, 31, 32, 33, 34, 26 except 20=1276(LC 1), 2=742(LC 1), 28=461(LC 1), 29=305(LC 1), 26=281(LC 19), 2=742(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-69=-368/3, 3-4=-760/35, 4-5=-690/35, 5-6=-699/43, 6-7=-693/49, 7-8=-687/56, 8-9=-672/65, 9-10=-753/86, 10-11=-723/90, 11-12=-967/149, 12-13=-881/184, 13-14=-1016/236, 14-15=-838/205, 15-16=-798/223, 16-17=-723/213, 17-18=-527/161, 18-19=-1130/95, 19-66=-1829/86, 20-66=-465/0 BOT CHORD 68-70=0/592, 34-70=0/592, 33-34=0/592, 32-33=0/592, 31-32=0/592, 30-31=0/592, 29-30=0/592, 28-29=0/592, 27-28=0/591, 26-27=0/591, 25-26=0/591, 24-25=0/588, 23-24=0/588, 22-23=0/1498, 22-67=0/1504, 65-67=-16/541 WEBS 19-23=-1210/214, 19-22=0/331, 25-37=-154/572, 35-37=-154/572, 23-38=0/520, 36-38=0/520, 18-36=0/384, 16-39=-257/784, 13-26=-279/93, 11-28=-378/69, 9-29=-294/41, 17-45=-284/58, 20-65=-673/26, 66-67=-565/251, 65-66=-771/24, 20-67=-28/703, 2-68=-458/32, 69-71=-18/261, 68-71=-626/24, 3-71=-656/43 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 2, 28, 29, 30, 31, 32, 33, 26, 2 except (jt=lb) 27=218, 34=153. LOAD CASE(S) Standard Job 304947-A Truss C3 Truss Type Roof Special Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:32 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-eNFEWRKPFNvWP?n00w7yOjzn9DEU3nCV3oSbvRz?nKX Scale = 1:66.6 T1 T2 T3 B1 W3 W4 W5 W1 W2 HW2B2 1 2 3 114 5 9 8 7 6 1210 5x5 4x6 6x6 2x4 3x6 3x8 2x3 6x6 6-11-4 6-11-4 13-5-2 6-5-14 21-5-4 8-0-2 6-11-4 6-11-4 13-5-2 6-5-14 21-5-4 8-0-2 22-7-4 1-2-0 4- 1 - 1 4- 7 - 5 12 - 2 - 3 0- 7 - 4 14.00 12 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-4], [4:0-0-3,0-0-1], [4:0-5-0,0-0-3], [4:Edge,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.99 0.63 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.26 0.01 (loc) 6-12 6-12 4 l/defl >999 >970 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W5: 2x3 SPF Stud, W1: 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 9 = 1104/Mechanical 4 = 1208/0-5-8 (min. 0-1-14) Max Horz 9 = -286(LC 6) Max Uplift 9 = -73(LC 9) 4 = -68(LC 9) Max Grav 9 = 1104(LC 1) 4 = 1208(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-911/146, 2-3=-903/136, 3-11=-1664/64, 4-11=-446/0, 1-9=-1039/108 BOT CHORD 8-9=-164/278, 7-8=-1/1354, 6-7=-1/1354, 6-12=0/1359, 10-12=-10/492 WEBS 2-8=-37/506, 3-8=-1078/210, 3-6=0/290, 1-8=-43/466, 4-10=-653/25, WEBS 2-8=-37/506, 3-8=-1078/210, 3-6=0/290, 1-8=-43/466, 4-10=-653/25, 11-12=-513/216, 10-11=-703/19, 4-12=-18/659 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 4. LOAD CASE(S) Standard Job 304947-A Truss D1 Truss Type Roof Special Girder Qty 1 Ply 3 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:36 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-X8VlLoNwJbPxuc5nFlCuZZ7Zardt?ae5_PQo2Cz?nKT Scale = 1:71.3 W1 T1 T2 T3 T4 W8 B1W3 W4 W5 W6 W7 W8 W9 W2 1 2 3 4 5 6 11 10 9 8 712 13 14 15 16 17 18 19 4x6 2x4 5x5 4x6 5x5 2x4 7x8 3x6 7x8 7x8 5x5 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 0-5-8 0-5-8 2-4-7 1-10-15 5-11-0 3-6-8 9-5-8 3-6-8 14-4-4 4-10-12 16-5-8 2-1-4 18-7-4 2-1-12 18-9-0 0-1-12 2-4-7 2-4-7 5-11-0 3-6-8 9-5-8 3-6-8 14-4-4 4-10-12 18-9-0 4-4-12 1- 6 - 7 4- 9 - 1 5 12 - 2 - 0 4- 9 - 1 5 18.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-3-0], [3:0-0-12,0-1-8], [4:0-2-8,0-2-0], [5:0-2-8,0-2-0], [6:0-1-12,0-2-4], [8:0-3-8,0-4-0], [9:0-4-0,0-4-0], [10:0-3-8,0-4-4], [11:0-2-12 ,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.58 0.54 0.65 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.24 0.03 (loc) 10-11 10-11 7 l/defl >999 >924 n/a L/d 240 180 n/a PLATES MT20 Weight: 404 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2700F 2.2E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2, 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 11 = 7338/0-5-8 (min. 0-3-13) 7 = 7474/0-3-8 (min. 0-2-1) Max Horz 11 = 285(LC 26) Max Uplift 11 = -318(LC 9) 7 = -374(LC 8) Max Grav 11 = 7338(LC 1) 7 = 7474(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-8113/402, 3-4=-5150/382, 4-5=-5092/363, 5-6=-5113/288, 6-7=-5721/295 BOT CHORD 11-12=-544/10007, 12-13=-544/10007, 13-14=-544/10007, 10-14=-544/10007, 10-15=-293/4455, 15-16=-293/4455, 9-16=-293/4455, 9-17=-249/5188, 17-18=-249/5188, 8-18=-249/5188 WEBS 2-10=-5856/323, 3-10=-184/5189, 3-9=-3441/358, 4-9=-533/7936, 5-9=-3256/233, 5-8=-2298/184, 6-8=-377/7540, 2-11=-11207/536 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=318, 7=374. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Use Simpson Strong-Tie HUS26 (14-10d Girder , 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-1-12 oc max. starting at 0-5-8 from the left end to 18-7-4 to connect truss(es) A5 (1 ply 2x4 SPF), A6 (1 ply 2x4 SPF), A7 (1 ply 2x4 SPF) to front face of bottom chord. 11) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-4=-84, 4-5=-84, 5-6=-84, 7-11=-20 Concentrated Loads (lb) Vert: 7=-1296(F) 8=-1287(F) 12=-1302(F) 13=-1287(F) 14=-1287(F) 15=-1287(F) 16=-1287(F) 17=-1287(F) 18=-1287(F) 19=-1287(F) Job 304947-A Truss E1 Truss Type Piggyback Base Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:38 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-TWcVmUOArCgf7wFANAEMe_C_xeMYTTBNRjvv65z?nKR Scale = 1:63.0 T1 T2 T3B1B1 W1 W1 HW1 HW1 1 2 9 3 4 12 5 6 8 10 7 13 11 5x5 5x5 6x6 6x8 6x6 5-5-1 5-5-1 9-5-8 4-0-7 13-5-13 4-0-5 18-11-0 5-5-3 -1-6-0 1-6-0 3-6-0 3-6-0 6-9-8 3-3-8 12-1-8 5-4-0 15-5-0 3-3-8 18-11-0 3-6-0 20-5-0 1-6-0 0- 1 1 - 4 11 - 1 - 8 0- 1 1 - 4 9- 0 - 0 18.00 12 12.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-2-3], [3:0-3-0,0-2-12], [4:0-3-0,0-2-12], [5:0-3-13,0-2-3], [7:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.27 0.27 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.28 0.59 (loc) 7 7-10 5 l/defl >999 >812 n/a L/d 240 180 n/a PLATES MT20 Weight: 120 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x3 SPF No.2 WEDGE Left: 2x3 SPF Stud, Right: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except 2-0-0 oc purlins (5-2-10 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2 = 1110/0-5-8 (min. 0-1-12) 5 = 1110/0-5-8 (min. 0-1-12) Max Horz 2 = -273(LC 6) Max Uplift 2 = -33(LC 9) 5 = -33(LC 8) Max Grav 2 = 1110(LC 1) 5 = 1110(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-806/0, 3-9=-2121/226, 3-4=-2846/280, 4-12=-2121/165, 5-12=-860/40 BOT CHORD 8-10=-277/545, 7-10=-371/1679, 7-13=-141/1581, 11-13=-150/468 WEBS 3-7=-102/2218, 4-7=-275/2295, 2-8=-570/0, 9-10=-649/374, 8-9=-705/26, 5-11=-636/11, 12-13=-629/247, 11-12=-705/32 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss E2 Truss Type GABLE L GABLE L GABL l MMON l l MON Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:41 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-u5IeOWR2872E_Nzk2Jn3GdqTRsLrgx1q8h7ZjQz?nKO Scale = 1:62.0 T2 T3 T2 B1 B1 W1 W2 W2 W1 ST6 ST5ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST1 T1 T1 1 2 36 3 4 5 6 7 8 9 10 11 12 13 14 15 40 16 17 35 37 32 31 30 29 28 26 25 24 22 21 20 19 18 41 39 33 34 38 42 27 23 4x8 6x6 6x6 4x8 5x8 3x4 3x4 0-5-8 0-5-8 7-1-11 6-8-3 7-5-12 0-4-1 9-5-8 1-11-12 11-5-4 1-11-12 11-9-5 0-4-1 18-5-8 6-8-3 18-11-0 0-5-8 -1-6-0 1-6-0 7-1-11 7-1-11 11-9-5 4-7-9 18-11-0 7-1-11 20-5-0 1-6-0 0- 1 1 - 4 11 - 1 - 8 0- 1 1 - 4 9- 0 - 0 18.00 12 12.00 12 Plate Offsets (X,Y)-- [8:0-2-15,Edge], [10:0-2-15,Edge], [25:0-6-4,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.38 0.49 0.32 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.19 -0.22 0.08 (loc) 31-32 18-19 16 l/defl >472 >409 n/a L/d 240 180 n/a PLATES MT20 Weight: 125 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.) (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 26-27,25-26,24-25,23-24. REACTIONS. All bearings 0-5-8 except (jt=length) 27=0-3-0, 23=0-3-0. (lb) - Max Horz 2= 429(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 27, 23 except 2=-507(LC 9), 16=-499(LC 9) Max Grav All reactions 250 lb or less at joint(s) except 2=919(LC 16), 16=908(LC 16), 27=948(LC 18), 23=953(LC 18) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-36=-458/154, 3-36=-566/238, 3-4=-481/253, 4-5=-544/384, 5-6=-479/495, 6-7=-537/700, 7-8=-335/598, 10-11=-460/703, 11-12=-700/835, 12-13=-625/621, 13-14=-647/510, 14-15=-519/289, 15-40=-583/272, 16-40=-484/198 BOT CHORD 35-37=-396/459, 32-37=-336/513, 31-32=-353/720, 30-31=-383/834, 29-30=-469/1018, 28-29=-403/960, 27-28=-336/864, 26-27=-298/380, 25-26=-293/414, 22-23=-15/718, 21-22=-82/629, 20-21=-205/687, BOT CHORD 35-37=-396/459, 32-37=-336/513, 31-32=-353/720, 30-31=-383/834, 29-30=-469/1018, 28-29=-403/960, 27-28=-336/864, 26-27=-298/380, 25-26=-293/414, 22-23=-15/718, 21-22=-82/629, 20-21=-205/687, 19-20=-55/516, 18-19=0/418, 18-41=0/280 WEBS 8-28=-557/215, 8-33=-269/393, 25-33=-244/399, 25-34=-500/600, 10-34=-492/574, 10-22=-732/503, 4-32=-287/246, 14-18=-299/256, 2-35=-595/267, 2-38=-44/302, 35-38=-317/117, 16-39=-608/306, 16-42=-2/274, 39-42=-276/84 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 2, 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 23 except (jt=lb) 2=507, 16=499. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 27, 23. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss E3 Truss Type PIGGYBACK BASE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:43 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qUQOpBSJglIyDh779kqXL2wqef4h8kF6b?cgoIz?nKM Scale = 1:63.0 T1 T2 T3 B1 B1 W1 W1 HW1 HW1 1 2 11 3 4 8 5 10 12 6 9 7 5x5 5x5 6x6 6x6 6x8 1 2 - 3 - 1 5 20-7-8 5-5-1 5-5-1 9-5-8 4-0-7 13-5-13 4-0-5 18-11-0 5-5-3 -1-6-0 1-6-0 3-6-0 3-6-0 6-9-8 3-3-8 12-1-8 5-4-0 15-5-0 3-3-8 18-11-0 3-6-0 0- 1 1 - 4 11 - 1 - 8 0- 1 1 - 4 9- 0 - 0 18.00 12 12.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-2-3], [3:0-3-0,0-2-12], [4:0-3-0,0-2-12], [5:0-3-13,0-2-3], [6:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.27 0.27 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.28 0.59 (loc) 6 6-12 5 l/defl >999 >817 n/a L/d 240 180 n/a PLATES MT20 Weight: 115 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x3 SPF No.2 WEDGE Left: 2x3 SPF Stud, Right: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc purlins, except 2-0-0 oc purlins (5-2-6 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 5 = 979/0-5-8 (min. 0-1-9) 2 = 1115/0-5-8 (min. 0-1-12) Max Horz 2 = 252(LC 5) Max Uplift 5 = -25(LC 8) 2 = -35(LC 9) Max Grav 5 = 979(LC 1) 2 = 1115(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-754/0, 3-11=-2137/262, 3-4=-2816/349, 4-8=-2142/201, 5-8=-708/68 BOT CHORD 10-12=-237/431, 6-12=-414/1525, 6-9=-185/1503, 7-9=-121/401 WEBS 3-6=-160/2100, 4-6=-333/2093, 5-7=-577/7, 8-9=-1087/483, 7-8=-919/70, 5-9=-62/420, 2-10=-541/0, 11-12=-637/398, 10-11=-710/36 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss E4 Truss Type Piggyback Base Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:45 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-mtX9EtUZCMYgT?HWH8s?QT?ADTlGcf5P2J5nsBz?nKK Scale = 1:62.9 T1 T2 T3 T4 W6 B1 B2 B3 W1 W2 W4 W3 W5 HW1 1 2 11 3 4 5 6 10 12 9 8 7 6x6 6x6 5x5 2x4 4x4 6x6 6x8 5x5 1 0 - 7 - 3 2 1-3-7 9-5-8 9-5-8 15-6-0 6-0-8 18-9-0 3-3-0 -1-6-0 1-6-0 6-9-8 6-9-8 12-1-8 5-4-0 16-6-8 4-5-0 18-9-0 2-2-8 0- 1 1 - 4 4- 6 - 0 11 - 1 - 8 1- 6 - 8 2- 1 1 - 8 6- 0 - 8 8- 2 - 0 18.00 12 12.00 12 Plate Offsets (X,Y)-- [2:0-3-13,0-2-3], [4:0-3-8,0-3-0], [5:0-2-8,0-2-12], [8:0-2-8,0-2-12], [9:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.26 0.27 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.27 0.42 (loc) 9 9-12 7 l/defl >999 >839 n/a L/d 240 180 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x3 SPF Stud *Except* W1,W2,W3: 2x3 SPF No.2 WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-4 oc purlins, except end verticals, and 2-0-0 oc purlins (5-3-4 max.): 3-4, 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 7 = 965/0-3-8 (min. 0-1-8) 2 = 1101/0-5-8 (min. 0-1-12) Max Horz 2 = 248(LC 5) Max Uplift 7 = -32(LC 8) 2 = -24(LC 8) Max Grav 7 = 965(LC 1) 2 = 1101(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-733/0, 3-11=-2095/271, 3-4=-2730/388, 4-5=-1900/150 BOT CHORD 10-12=-194/307, 9-12=-417/1458, 8-9=-196/1447, 7-8=-86/1699 WEBS 3-9=-201/2025, 4-9=-364/2037, 5-8=-1159/177, 4-8=-232/301, 5-7=-1833/103, 2-10=-537/0, 11-12=-625/430, 10-11=-697/39 WEBS 3-9=-201/2025, 4-9=-364/2037, 5-8=-1159/177, 4-8=-232/301, 5-7=-1833/103, 2-10=-537/0, 11-12=-625/430, 10-11=-697/39 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss E5 Truss Type Piggyback Base Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:47 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-iFfvfZVpjzoOiIRuOZuTVu4X5GRp4YOiWdaux3z?nKI Scale = 1:60.8 T1 T2 T3 T4 W6 B1 B2 B3 W1 W2 W4 W3 W5 HW1 1 10 2 3 4 5 9 11 8 7 6 4x6 6x6 6x6 5x5 2x4 4x4 6x8 5x5 9-5-8 9-5-8 15-6-0 6-0-8 18-9-0 3-3-0 6-9-8 6-9-8 12-1-8 5-4-0 16-6-8 4-5-0 18-9-0 2-2-8 0- 1 1 - 4 4- 6 - 0 11 - 1 - 8 1- 6 - 8 2- 1 1 - 8 6- 0 - 8 8- 2 - 0 18.00 12 12.00 12 Plate Offsets (X,Y)-- [1:0-2-13,0-1-3], [3:0-3-8,0-3-0], [4:0-2-8,0-2-12], [7:0-2-8,0-2-12], [8:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.24 0.26 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.27 0.42 (loc) 8 8-11 6 l/defl >999 >827 n/a L/d 240 180 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x3 SPF Stud *Except* W1,W2,W3: 2x3 SPF No.2 WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-11 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-15 max.): 2-3, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 970/0-5-8 (min. 0-1-8) 6 = 970/0-3-8 (min. 0-1-8) Max Horz 1 = 220(LC 5) Max Uplift 1 = -10(LC 9) 6 = -35(LC 8) Max Grav 1 = 970(LC 1) 6 = 970(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-628/12, 2-10=-2117/275, 2-3=-2767/395, 3-4=-1911/156 BOT CHORD 9-11=-182/329, 8-11=-422/1485, 7-8=-199/1459, 6-7=-91/1709 WEBS 2-8=-205/2048, 3-8=-370/2070, 4-7=-1165/178, 3-7=-231/301, 4-6=-1844/108, 1-9=-519/0, 10-11=-1081/709, 9-10=-909/140, WEBS 2-8=-205/2048, 3-8=-370/2070, 4-7=-1165/178, 3-7=-231/301, 4-6=-1844/108, 1-9=-519/0, 10-11=-1081/709, 9-10=-909/140, 1-11=-88/416 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss G1 Truss Type Common Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:49 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-fenf4FX4Fb25xcaHW_xxaJAp_47kYah?zx3_?yz?nKG Scale = 1:68.0 T1 T1 B1 W3 W1 W2 W1 W2 1 2 3 6 5 4 2x4 2x4 4x6 6x6 3x8 6x6 6-6-0 6-6-0 13-0-0 6-6-0 6-6-0 6-6-0 13-0-0 6-6-0 2- 5 - 0 12 - 2 - 0 2- 5 - 0 18.00 12 Plate Offsets (X,Y)-- [1:0-3-4,0-1-0], [3:0-3-4,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.47 0.30 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.09 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3: 2x3 SPF No.2, W2: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 661/0-5-8 (min. 0-1-8) 4 = 661/0-5-8 (min. 0-1-8) Max Horz 6 = 206(LC 7) Max Uplift 6 = -69(LC 9) 4 = -69(LC 8) Max Grav 6 = 661(LC 1) 4 = 661(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-580/131, 2-3=-580/131, 1-6=-604/99, 3-4=-604/99 BOT CHORD 5-6=-246/274 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. LOAD CASE(S) Standard Job 304947-A Truss G2 Truss Type COMMON SUPPORTED GAB Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:51 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-b1vQVwYKnCIpBwkfdPzPgkFF8uql0S3IRFY54rz?nKE Scale = 1:69.5 W1 T1 T1 W1 B1 ST5 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 W3 W4W4 W2 W2 12 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 2223 25 24 2628 27 3x5 3x4 4x4 3x4 3x5 5x5 5x5 3-0-8 4- 1 1 - 1 1 4-11-12 4-11-12 8-0-4 3-0-8 13-0-0 4-11-12 6-6-0 6-6-0 12-8-8 6-2-8 13-0-0 0-3-8 1- 1 0 - 1 1 11 - 7 - 1 1 1- 1 0 - 1 1 18.00 12 Plate Offsets (X,Y)-- [1:0-0-12,0-1-8], [11:0-0-12,0-1-8], [12:0-2-12,0-1-8], [13:0-2-8,0-3-0], [20:0-2-8,0-3-0], [21:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-3 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.11 0.13 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 12 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 96 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W1: 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1, 6, 11, 22, 25, 26 REACTIONS. All bearings 13-0-0. (lb) - Max Horz 21=-328(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 16, 17 except 21=-519(LC 6), 12=-505(LC 7), 18=-202(LC 8), 19=-166(LC 8), 20=-735(LC 8), 15=-204(LC 9), 14=-166(LC 9), 13=-730(LC 9) Max Grav All reactions 250 lb or less at joint(s) 18, 15 except 21=1060(LC 8), 12=1052(LC 9), 19=268(LC 15), 20=452(LC 6), 14=268(LC 16), 13=444(LC 7), 16=404(LC 16), 17=411(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-21=-1029/519, 1-2=-581/310, 2-3=-433/244, 3-4=-298/166, 8-9=-294/158, 9-10=-428/237, 10-11=-576/301, 11-12=-1021/506 BOT CHORD 20-21=-320/323, 19-20=-177/350, 18-19=-177/350, 17-18=-176/349, 16-17=-176/349, 15-16=-176/349, 14-15=-176/350, 13-14=-176/349 WEBS 1-20=-336/657, 11-13=-330/653 WEBS 1-20=-336/657, 11-13=-330/653 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 17 except (jt=lb) 21=519, 12=505, 18=202, 19=166, 20=735, 15=204, 14=166, 13=730. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss G3 Truss Type Common Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:53 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-XP0AwcaaJpZXQDu2lq?tl9KV_hUgUOCbuZ1C8jz?nKC Scale = 1:68.0 T1 T1 B1 W3 W1 W1 W2W2 1 2 3 6 5 4 2x4 2x4 4x6 6x6 6x6 3x8 0-2-0 0-2-0 6-6-0 6-4-0 13-0-0 6-6-0 0-3-12 0-3-12 6-6-0 6-2-4 13-0-0 6-6-0 2- 5 - 0 12 - 2 - 0 2- 5 - 0 18.00 12 Plate Offsets (X,Y)-- [1:0-3-4,0-1-0], [3:0-3-4,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.47 0.30 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.09 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3: 2x3 SPF No.2, W2: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 661/0-3-8 (min. 0-1-8) 4 = 661/0-5-8 (min. 0-1-8) Max Horz 6 = -269(LC 4) Max Uplift 6 = -64(LC 9) 4 = -64(LC 8) Max Grav 6 = 661(LC 1) 4 = 661(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-580/132, 2-3=-580/132, 1-6=-604/94, 3-4=-604/95 BOT CHORD 5-6=-291/313 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. LOAD CASE(S) Standard Job 304947-A Truss G4 Truss Type Common Girder Qty 1 Ply 2 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:56 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-x_iJYecTckx6HhddQyZaMnytWvT7hh_1aXGsl2z?nK9 Scale = 1:71.3 T1 T1 B1 W3 W2W2 W1 W1 1 2 3 6 5 47 8 9 10 11 12 4x6 4x6 4x6 5x5 5x5 7x8 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 0-2-0 0-2-0 1-6-8 1-4-8 3-6-8 2-0-0 5-6-8 2-0-0 6-6-0 0-11-8 7-5-12 0-11-12 9-5-12 2-0-0 11-5-12 2-0-0 12-8-4 1-2-8 13-0-0 0-3-12 6-6-0 6-6-0 13-0-0 6-6-0 2- 5 - 0 12 - 2 - 0 2- 5 - 0 18.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-0], [3:0-3-0,0-1-0], [4:Edge,0-3-8], [5:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.96 0.50 0.43 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.14 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 179 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2700F 2.2E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6 = 3866/0-3-8 (min. 0-3-1) 4 = 3897/0-5-8 (min. 0-3-1) Max Horz 6 = 267(LC 5) Max Uplift 6 = -277(LC 9) 4 = -298(LC 8) Max Grav 6 = 3866(LC 1) 4 = 3897(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2644/271, 2-3=-2644/271, 1-6=-2653/230, 3-4=-2651/230 BOT CHORD 6-7=-311/408, 7-8=-311/408, 8-9=-311/408, 5-9=-311/408, 5-10=-120/255, 10-11=-120/255, 11-12=-120/255, 4-12=-120/255 WEBS 2-5=-232/3521, 3-5=-219/1180, 1-5=-221/1184 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=277, 4=298. 8) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 1-6-8 from the left end to 11-5-12 to connect truss(es) B1 (1 ply 2x4 SPF), B2 (1 ply 2x4 SPF), C3 (1 ply 2x4 SPF) to back face of bottom chord. 9) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-3=-84, 4-6=-20 Concentrated Loads (lb) Vert: 7=-1068(B) 8=-1068(B) 9=-1068(B) 10=-1068(B) 11=-1084(B) 12=-1084(B) Job 304947-A Truss H1 Truss Type Common Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:05:58 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-uNq3zKej8MBqX?m0YNb2SC1KIi7F9fAK2rlzqxz?nK7 Scale = 1:54.4 T1 T1 B1 W1 HW1 HW1 1 6 2 9 3 5 7 4 10 81112 2x4 4x4 6x6 6x6 6-0-0 6-0-0 12-0-0 6-0-0 6-0-0 6-0-0 12-0-0 6-0-0 0- 8 - 0 9- 8 - 0 0- 8 - 0 18.00 12 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-3-10,0-1-13], [1:Edge,0-2-12], [3:0-0-10,0-0-14], [3:0-3-10,0-1-13], [3:Edge,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.56 0.53 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.11 -0.14 0.03 (loc) 4-7 4-7 1 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 WEDGE Left: 2x6 SPF 1650F 1.5E, Right: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 624/0-5-8 (min. 0-1-8) 3 = 624/0-5-8 (min. 0-1-8) Max Horz 1 = 194(LC 7) Max Uplift 1 = -47(LC 9) 3 = -47(LC 8) Max Grav 1 = 671(LC 16) 3 = 671(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-327/115, 2-6=-680/131, 2-9=-679/131, 3-9=-330/120 BOT CHORD 5-7=-196/323, 7-11=-42/326, 4-11=-42/326, 4-12=-42/326, 10-12=-42/326 WEBS 2-4=-28/397, 1-5=-329/3, 6-7=-523/558, 5-6=-290/37, 3-8=-334/10, 9-10=-517/553, 8-9=-281/25 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard Job 304947-A Truss H2 Truss Type COMMON SUPPORTED GAB Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:00 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qlxqO?fzfzRXmIwOfodWXd7nwWwhdXZdV8E4upz?nK5 Scale = 1:49.7 T1 T1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 103x4 4x4 3x4 12-0-0 12-0-0 6-0-0 6-0-0 12-0-0 6-0-0 0- 1 - 1 1 9- 1 - 1 1 0- 1 - 1 1 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-3 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.10 0.08 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST4: 2x3 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.) (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-13 REACTIONS. All bearings 12-0-0. (lb) - Max Horz 1=-300(LC 4) Max Uplift All uplift 100 lb or less at joint(s) except 1=-172(LC 6), 9=-142(LC 7), 14=-143(LC 8), 15=-160(LC 8), 16=-225(LC 8), 12=-139(LC 9), 11=-161(LC 9), 10=-225(LC 9) Max Grav All reactions 250 lb or less at joint(s) 13, 15, 11 except 1=371(LC 8), 9=353(LC 9), 14=258(LC 15), 16=350(LC 15), 12=253(LC 16), 10=350(LC 16) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-456/288, 2-3=-251/182, 8-9=-435/252 BOT CHORD 1-16=-158/298, 15-16=-158/299, 14-15=-158/299, 13-14=-158/299, 12-13=-158/299, 11-12=-157/299, 10-11=-157/298, 9-10=-156/297 WEBS 2-16=-272/241, 8-10=-272/241 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 172 lb uplift at joint 1, 142 lb uplift at joint 9, 143 lb uplift at joint 14, 160 lb uplift at joint 15, 225 lb uplift at joint 16, 139 lb uplift at joint 12, 161 lb uplift at joint 11 and 225 lb uplift at joint 10. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss H3 Truss Type Common Girder Qty 1 Ply 2 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:02 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-m83aohhDBahF?c4nnDg_c2CvpJVs5MGvzSjAziz?nK3 Scale = 1:56.8 T1 T1 B1 W1 1 6 2 9 3 5 7 4 1081112 13 14 1516 6x6 6x6 4x8 4x6 HUS26 HUS26 HUS26 HUS26 HUS26 2-0-0 2-0-0 6-0-0 4-0-0 10-0-0 4-0-0 12-0-0 2-0-0 6-0-0 6-0-0 12-0-0 6-0-0 0- 8 - 0 9- 8 - 0 0- 8 - 0 18.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-10], [2:0-2-8,0-2-0], [3:0-0-0,0-0-10], [4:0-4-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.97 0.55 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.16 0.01 (loc) 4-7 4-7 1 l/defl >999 >916 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2700F 2.2E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1 = 4204/0-5-8 (min. 0-3-5) 3 = 4194/0-5-8 (min. 0-3-5) Max Horz 1 = -194(LC 4) Max Uplift 1 = -283(LC 9) 3 = -231(LC 8) Max Grav 1 = 4204(LC 1) 3 = 4194(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-2174/544, 2-6=-3620/298, 2-9=-3621/299, 3-9=-2171/528 BOT CHORD 5-7=-406/695, 7-11=-135/1902, 11-12=-135/1902, 12-13=-135/1902, 4-13=-135/1902, 4-14=-135/1902, 14-15=-135/1902, 15-16=-135/1902, 10-16=-135/1902, 8-10=-304/584 WEBS 2-4=-317/5193, 1-5=-1957/510, 6-7=-1172/1234, 5-6=-1219/100, 1-7=-99/733, 3-8=-1953/489, 9-10=-1152/1226, 8-9=-1219/94, 3-10=-106/732 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 283 lb uplift at joint 1 and 231 lb uplift at joint 3. 8) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-0 from the left end to 10-0-0 to connect truss(es) A2 (1 ply 2x4 SPF), A1 (1 ply 2x4 SPF), A4 (1 ply 2x4 SPF) to back face of bottom chord. 9) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-3=-84, 5-8=-20 Concentrated Loads (lb) Vert: 4=-1427(B) 11=-1442(B) 13=-1427(B) 14=-1427(B) 16=-1427(B) Job 304947-A Truss J1 Truss Type JACK-OPEN Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:04 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-iXBKDNjUjCxzFwE9ueiShTHUn7IyZPjCQmCH1az?nK1 Scale = 1:19.4 T1 B1 HW1 1 5 4 6 2 3 3x4 1-11-4 1-11-4 1-11-4 1-11-4 0- 8 - 0 3- 6 - 1 4 18.00 12 Plate Offsets (X,Y)-- [1:0-0-14,0-0-10], [1:0-1-13,0-3-10] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.05 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 6 6 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2 = 64/Mechanical 3 = 36/Mechanical 1 = 100/0-5-8 (min. 0-1-8) Max Horz 1 = 87(LC 8) Max Uplift 2 = -68(LC 8) 3 = -18(LC 8) Max Grav 2 = 76(LC 15) 3 = 42(LC 15) 1 = 109(LC 17) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 68 lb uplift at joint 2 and 18 lb uplift at joint 3. LOAD CASE(S) Standard Job 304947-A Truss K1 Truss Type Common Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:05 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-BjljRjj6UV3qs3pMSLDhEhqaxXdEIrEMfQxrZ1z?nK0 Scale = 1:36.3 T1 T1 B1 W1 1 2 3 43x4 4x4 3x4 2x3 4-0-0 4-0-0 8-0-0 4-0-0 4-0-0 4-0-0 8-0-0 4-0-0 0- 0 - 1 0 6- 0 - 1 0 0- 0 - 1 0 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.34 0.12 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 284/8-0-0 (min. 0-1-8) 3 = 284/8-0-0 (min. 0-1-8) 4 = 215/8-0-0 (min. 0-1-8) Max Horz 1 = 122(LC 5) Max Uplift 1 = -54(LC 9) 3 = -48(LC 8) Max Grav 1 = 284(LC 1) 3 = 284(LC 1) 4 = 215(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 48 lb uplift at joint 3. LOAD CASE(S) Standard Job 304947-A Truss L1 Truss Type Flat Girder Qty 1 Ply 2 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:08 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-bIQr3km_nQSPjXXx7UmOsJS6LkaSV5CoLOAV9Mz?nJz Scale = 1:22.7 W1 T1 W1 B1 W2 W1 W2 1 2 3 6 5 4 7 8 9 10 3x4 3x4 8x10 4x6 2x3 4x6 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 2-0-0 2-0-0 4-0-0 2-0-0 5-0-0 1-0-0 6-0-0 1-0-0 8-0-0 2-0-0 10-0-0 2-0-0 0-1-12 0-1-12 5-0-0 4-10-4 10-0-0 5-0-0 4- 2 - 4 Mark this chord UP Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [3:0-3-0,0-1-12], [5:0-5-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.27 0.41 0.48 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.10 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 119 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2700F 2.2E WEBS 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-3, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6 = 3829/0-3-8 (min. 0-3-0) 4 = 3511/0-5-8 (min. 0-2-12) Max Horz 6 = -108(LC 4) Max Uplift 6 = -355(LC 4) 4 = -342(LC 5) Max Grav 6 = 3829(LC 1) 4 = 3511(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-2734/287, 1-2=-3148/288, 2-3=-3148/288, 3-4=-2612/282 WEBS 1-5=-383/3908, 2-5=-432/137, 3-5=-384/3919 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 355 lb uplift at joint 6 and 342 lb uplift at joint 4. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-0 from the left end to 8-0-0 to connect truss(es) A8 (1 ply 2x4 SPF), B1 (1 ply 2x4 SPF) to front face of bottom chord. 10) Use Simpson Strong-Tie HUS26 (14-10d Girder , 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-0 from the left end to 8-0-0 to connect truss(es) M1 (1 ply 2x4 SPF) to back face of bottom chord. 11) Fill all nail holes where hanger is in contact with lumber. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 128 lb down and 12 lb up at 0-1-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Standard Vert: 1-3=-84, 4-6=-20 Concentrated Loads (lb) Vert: 1=-128 7=-1782(F=-1376, B=-405) 8=-1474(F=-1068, B=-405) 9=-1474(F=-1068, B=-405) 10=-1474(F=-1068, B=-405) Job 304947-A Truss M1 Truss Type Roof Special Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:10 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-XgYcUQnFJ2i7zrhJFupsxkXPGYEIz6C5oifbEEz?nJx Scale = 1:22.9 T1 W1 B11 2 6 3 5 7 4 2x4 2x4 4x6 8-6-0 8-6-0 -1-6-0 1-6-0 8-6-0 8-6-0 0- 7 - 1 2 4- 2 - 4 5.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.50 0.51 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.40 0.03 (loc) 4-7 4-7 2 l/defl >688 >251 n/a L/d 240 180 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 4 = 425/Mechanical 2 = 574/0-5-8 (min. 0-1-8) Max Horz 2 = 128(LC 7) Max Uplift 4 = -52(LC 8) 2 = -57(LC 8) Max Grav 4 = 425(LC 1) 2 = 574(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-342/85 WEBS 2-5=-401/0, 6-7=-9/610 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 4 and 57 lb uplift at joint 2. LOAD CASE(S) Standard Job 304947-A Truss M2 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:11 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-?t6_hmot4Lq_a_GVocK5Ty4d5xhAiZnE1MO9mgz?nJw Scale = 1:22.6 T1 W1 B1 ST5 ST4 ST3 ST2 ST1 1 2 3 4 5 6 7 8 14 13 12 11 10 9 2x4 2x4 4x4 -1-6-0 1-6-0 8-6-0 8-6-0 0- 7 - 1 2 4- 2 - 4 5.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.23 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 8-6-0. (lb) - Max Horz 2= 127(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 9, 2, 10, 11, 12, 13, 14 Max Grav All reactions 250 lb or less at joint(s) 9, 10, 11, 12, 13, 14 except 2=269(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x3 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2, 10, 11, 12, 13, 14. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. LOAD CASE(S) Standard Job 304947-A Truss MA1 Truss Type Monopitch Qty 12 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:13 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-yFEk6Sp7cz4hqIQuw1MZZN9zGlMDATxXVgtGrZz?nJu Scale = 1:10.6 T1 W1 B1 HW11 2 7 3 4 6 8 5 9 2x4 3x8 4x4 2x4 2-4-0 2-4-0 -1-0-0 1-0-0 2-4-0 2-4-0 0- 1 0 - 4 1- 8 - 1 2 4.50 12 Plate Offsets (X,Y)-- [2:0-5-12,0-0-5], [4:0-2-11,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.26 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 8 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud SLIDER Left 2x6 SPF 1650F 1.5E 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 5 = 316/Mechanical 4 = -0/Mechanical Max Horz 5 = -351(LC 1) 4 = 351(LC 1) Max Uplift 5 = -80(LC 4) Max Grav 5 = 316(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-101/416, 4-5=-263/67 BOT CHORD 6-8=-351/117, 5-8=-351/117 WEBS 6-9=-106/331, 3-9=-118/415 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Job 304947-A Truss MA2 Truss Type Monopitch Qty 6 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:15 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-ueLUX8rN7aKP3caH1SP1eoFL9Z3IeN5qy_MMvSz?nJs Scale = 1:17.5 T1 W3 B1 W1 W21 2 3 5 4 2x4 3x4 4x4 3x4 1-3-8 1-3-8 -0-6-0 0-6-0 1-3-8 1-3-8 2- 1 1 - 1 4 0- 5 - 1 2 3- 2 - 0 2- 5 - 9 18.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.10 0.01 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 5 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 4 = 163/Mechanical 3 = 0/Mechanical Max Horz 4 = -73(LC 15) 3 = 67(LC 16) Max Uplift 4 = -21(LC 8) Max Grav 4 = 163(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Job 304947-A Truss N1 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:17 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-q1TFyptefBa7Iwjf9tRVjDKfeMjL6GK7PIrT_Kz?nJq Scale = 1:14.8 T1 W1 B1 ST11 2 3 5 4 3x4 2x4 2x4 2x3 2x3 6-1-12 6-1-12 0- 0 - 8 2- 7 - 4 5.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.23 0.10 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = -19/6-1-12 (min. 0-1-8) 4 = 164/6-1-12 (min. 0-1-8) 5 = 418/6-1-12 (min. 0-1-8) Max Horz 1 = 73(LC 5) Max Uplift 1 = -19(LC 1) 4 = -17(LC 8) 5 = -61(LC 8) Max Grav 1 = 25(LC 5) 4 = 164(LC 1) 5 = 418(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-338/109 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 4-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. LOAD CASE(S) Standard Job 304947-A Truss P1 Truss Type Piggyback Qty 9 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:19 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-mPb?NVuuBpqrYDt2GHTzoeP13AQjaBzQtcKa2Dz?nJo Scale: 1/2"=1' T1 T1 B1 ST1 1 2 3 4 5 6 4x4 3x4 3x4 2x3 0-5-7 0-5-7 4-10-9 4-5-3 5-4-0 0-5-7 2-8-0 2-8-0 5-4-0 2-8-0 0- 6 - 9 4- 0 - 0 0- 1 - 9 0- 6 - 9 0- 1 - 9 18.00 12 Plate Offsets (X,Y)-- [2:0-2-15,0-1-8], [4:0-2-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.11 0.04 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2 = 172/4-5-3 (min. 0-1-8) 4 = 172/4-5-3 (min. 0-1-8) 6 = 125/4-5-3 (min. 0-1-8) Max Horz 2 = -81(LC 4) Max Uplift 2 = -35(LC 9) 4 = -31(LC 8) Max Grav 2 = 172(LC 1) 4 = 172(LC 1) 6 = 125(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job 304947-A Truss P2 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:21 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-jojmoBw8jQ4ZnX1QOiVRt3UOqz6f256iKwph75z?nJm Scale = 1:18.0 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 6 7 10 9 8 4x4 3x4 3x4 2x3 2x3 2x3 2x3 2x3 0-5-7 0-5-7 4-2-3 3-8-12 4-7-9 0-5-7 2-3-13 2-3-13 4-7-9 2-3-13 0- 6 - 9 3- 5 - 1 1 0- 1 - 9 0- 6 - 9 0- 1 - 9 18.00 12 Plate Offsets (X,Y)-- [2:0-2-15,0-1-8], [6:0-2-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.03 0.01 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 6 6 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 3-8-12. (lb) - Max Horz 2= -69(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 6 except 10=-107(LC 8), 8=-107(LC 9) Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6 except (jt=lb) 10=107, 8=107. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job 304947-A Truss P3 Truss Type GABLE Qty 12 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:22 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-B_H8?XwmUkCQPhcdyQ1gQG1ZbNSqnYUsZZZEfYz?nJl Scale = 1:26.5 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 1 2 3 4 5 6 7 8 9 14 13 12 11 10 4x4 3x4 3x4 0-6-3 0-6-3 7-5-14 6-11-12 8-0-1 0-6-3 4-0-0 4-0-0 8-0-1 4-0-0 0- 5 - 1 0 4- 8 - 1 0- 1 - 9 0- 5 - 1 0 0- 1 - 9 14.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [8:0-2-10,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.02 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 8 8 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 6-11-12. (lb) - Max Horz 2= -90(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11, 10. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job 304947-A Truss P4 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:24 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7NOuQDy10LT8e_m?3r38Vh6vsB7EFSr90t2LjQz?nJj Scale = 1:24.5 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 6 7 10 9 8 4x4 3x4 3x4 2x3 2x3 2x3 2x3 2x3 0-6-3 0-6-3 6-7-13 6-1-10 7-2-0 0-6-3 3-7-0 3-7-0 7-2-0 3-7-0 0- 5 - 1 0 4- 2 - 3 0- 1 - 9 0- 5 - 1 0 0- 1 - 9 14.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [6:0-2-10,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.04 0.02 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 6 7 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 6-1-10. (lb) - Max Horz 2= -80(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 10, 8. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job 304947-A Truss R1 Truss Type Piggyback Base Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:26 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-3lWfru_HYyjrtIvOBF5ca6C2c_fqjCsSUBXSoJz?nJh Scale = 1:58.8 T1 T2 T3 T4 B1 W3 W4 W5 W6 W5 W1 W2 W8 B1 W7 1 2 3 4 5 6 71312 11 10 9 814 4x6 6x6 5x8 3x4 3x6 3x6 3x4 3x8 4x8 3x4 4x8 7-1-2 7-1-2 12-2-0 5-0-14 20-2-1 8-0-1 28-0-0 7-9-15 -2-0-0 2-0-0 7-1-2 7-1-2 12-2-0 5-0-14 20-2-1 8-0-1 25-0-0 4-9-15 27-6-8 2-6-8 28-0-0 0-5-8 30-0-0 2-0-0 1- 9 - 8 4- 1 - 1 4 10 - 0 - 1 4 0- 1 1 - 4 10 - 0 - 1 4 4.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-3-8,0-1-4], [4:0-2-11,Edge], [5:0-2-11,Edge], [6:0-2-0,0-1-12], [11:0-1-12,0-1-8], [12:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.86 0.65 0.60 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.32 0.04 (loc) 9-11 9-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x4 SPF 2100F 1.8E T4: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* W3,W4: 2x3 SPF Stud W6: 2x4 SPF No.2 W1,W8: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-6-8 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-11, 4-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 13 = 1619/0-5-8 (min. 0-2-9) 8 = 1619/0-5-8 (min. 0-2-9) Max Horz 13 = 244(LC 7) Max Uplift 13 = -110(LC 4) 8 = -61(LC 9) Max Grav 13 = 1619(LC 1) 8 = 1619(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2097/67, 3-4=-1668/95, 4-5=-828/129, 5-6=-1534/71, 2-13=-1546/148, 6-8=-1549/104 BOT CHORD 12-13=-198/284, 11-12=-91/1895, 10-11=-66/998, 10-14=-66/998, 9-14=-66/998, 8-9=-253/417 WEBS 3-12=-284/73, 3-11=-1130/162, WEBS 3-12=-284/73, 3-11=-1130/162, 4-11=-23/833, 4-9=-377/95, 5-9=0/429, 2-12=0/1732, 6-9=-184/635 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 13=110. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss R2 Truss Type Piggyback Base Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:28 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-?8ePGa?X3azZ7c3nIg74fXHLIoKwB66kxV0YsBz?nJf Scale = 1:58.8 T1 T2 T3 T4 B1 W3 W4 W5 W1 W2 W10 W6 W5 B1 W8 W9 W7 1 2 3 4 5 6 7 81514 13 12 11 10 916 4x6 6x6 4x6 3x6 3x4 3x6 3x4 3x4 4x8 4x6 3x4 3x4 3x8 7-1-2 7-1-2 12-2-0 5-0-14 20-2-1 8-0-1 23-11-0 3-8-15 28-0-0 4-1-0 -2-0-0 2-0-0 7-1-2 7-1-2 12-2-0 5-0-14 20-2-1 8-0-1 23-11-0 3-8-15 28-0-0 4-1-0 30-0-0 2-0-0 1- 9 - 8 4- 1 - 1 4 10 - 0 - 1 4 0- 1 1 - 4 10 - 0 - 1 4 4.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-3-8,0-1-4], [4:0-2-11,Edge], [5:0-3-2,0-2-0], [6:0-1-8,0-1-8], [7:0-3-4,0-0-8], [10:0-1-12,0-1-8], [13:0-1-12,0-1-8], [14:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.97 0.74 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.35 0.04 (loc) 11-13 11-13 9 l/defl >999 >934 n/a L/d 240 180 n/a PLATES MT20 Weight: 137 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W5,W2: 2x3 SPF No.2 W1,W10: 2x6 SPF 1650F 1.5E W6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-4-5 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-10. WEBS 1 Row at midpt 3-13, 4-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 9 = 1791/0-5-8 (min. 0-2-13) 15 = 1647/0-5-8 (min. 0-2-9) Max Horz 15 = 244(LC 7) Max Uplift 9 = -77(LC 9) 15 = -112(LC 4) Max Grav 9 = 1791(LC 1) 15 = 1647(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2148/73, 3-4=-1722/99, 4-5=-874/129, 5-6=-1438/119, 6-7=-1655/62, 2-15=-1573/151, 7-9=-1738/101 BOT CHORD 14-15=-198/285, 13-14=-96/1944, 12-13=-68/1034, 12-16=-68/1034, 11-16=-68/1034, 10-11=0/983 BOT CHORD 14-15=-198/285, 13-14=-96/1944, 12-13=-68/1034, 12-16=-68/1034, 11-16=-68/1034, 10-11=0/983 WEBS 3-14=-298/72, 3-13=-1146/165, 4-13=-19/846, 2-14=0/1780, 4-11=-344/80, 5-11=-34/528, 7-10=-18/1009 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 15=112. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 200 lb down and 19 lb up at 23-11-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-3=-84, 3-4=-84, 4-5=-84, 5-7=-84 , 7-8=-84, 9-15=-20 Concentrated Loads (lb) Vert: 6=-200 Job 304947-A Truss R3 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:31 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-QjJYuc1QMVL8_3oLzphnHAvxR?V6OY?BdTEDTWz?nJc Scale = 1:63.0 W1 T2 T3 T4 T5 B1 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9 ST10 ST11 ST11 ST11 ST10 ST12 ST13 ST14 ST15 ST16T1 T6 B1 ST17 W3 W4 W4 HW2 W2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 50 49 48 47 46 45 44 43 42 41 4039 38 37 36 35 34 33 32 31 30 29 54 51 52 53 55 56 57 2x4 5x8 3x6 3x6 3x6 5x8 3x6 3x4 3x6 2x4 2x4 2x4 3x4 5x12 2x4 2x4 6- 1 - 0 3-0-8 28-0-0 28-0-0 -2-0-0 2-0-0 7-1-2 7-1-2 12-7-0 5-5-14 14-7-1 2-0-1 17-7-9 3-0-8 17-8-4 0-0-11 19-9-0 2-0-12 28-0-0 8-3-0 30-0-0 2-0-0 1- 9 - 8 3- 1 0 - 3 10 - 3 - 1 0- 1 1 - 4 10 - 3 - 1 4.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-2-8], [3:0-4-15,0-1-4], [14:0-4-8,0-1-12], [19:0-4-8,0-1-12], [26:0-0-12,0-2-4], [27:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.66 0.07 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 0.01 0.02 (loc) 28 28 27 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 187 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W3: 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST8,ST9,ST10,ST12,ST13: 2x3 SPF No.2 SLIDER BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 49-50. WEBS 1 Row at midpt 13-41, 20-34 JOINTS 1 Brace at Jt(s): 2, 9, 14, 19, 51, 53, 54, 55 REACTIONS. All bearings 28-0-0. (lb) - Max Horz 50= 364(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 48, 47, 46, 45, 44, 41, 40, 38, 36, 27, 29 except 50=-198(LC 4), 49=-236(LC 8), 43=-115(LC 8), 42=-124(LC 8), 33=-126(LC 9), 32=-109(LC 9), 31=-108(LC 9), 30=-102(LC 9) Max Grav All reactions 250 lb or less at joint(s) 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 37, 35, 34, 33, 32, 31, 30, 29 except 50=612(LC 1), 38=307(LC 20), 36=307(LC 19), 27=610(LC 20) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-50=-594/207, 24-25=-264/182, TOP CHORD 2-50=-594/207, 24-25=-264/182, 25-26=-276/168, 26-27=-355/188 BOT CHORD 49-50=-350/289, 48-49=-178/362, 47-48=-178/362, 46-47=-178/362, 45-46=-178/362, 44-45=-178/362, 43-44=-178/362, 42-43=-178/362, 41-42=-178/362, 40-41=-178/362, 39-40=-178/362, 38-39=-178/362, 37-38=-178/362, 36-37=-178/362, 35-36=-178/362, 34-35=-178/362, 33-34=-178/362, 32-33=-178/362, 31-32=-178/362, 30-31=-178/361, 29-30=-177/361, 27-29=-174/355 WEBS 38-51=-265/73, 36-53=-265/71, 16-56=-346/99, 17-57=-344/95, 2-49=-93/368 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x3 MT20 unless otherwise indicated. 6) The Fabrication Tolerance at joint 27 = 8% 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 48, 47, 46, 45, 44, 41, 40, 38, 36, 27, 29 except (jt=lb) 50=198, 49=236, 43=115, 42=124, 33=126, 32=109, 31=108, 30=102. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss R4 Truss Type Piggyback Base Girder Qty 1 Ply 2 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:33 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-M6RIJI3gu6bsDNyk5EjFMb_Cxp41sIbT5njJYPz?nJa Scale = 1:58.8 T1 T2 T3 T4 B2 W3 W6 W7 W2 W1 W9 W8B1 W5 W41 2 3 4 5 6 7131211 10 9 814 15 4x6 6x12 4x4 4x6 3x4 3x8 3x8 4x8 4x6 3x8 4x10 3-7-13 3-7-13 7-1-2 3-5-5 10-7-12 3-6-10 12-2-0 1-6-4 19-11-9 7-9-9 20-2-1 0-2-8 23-11-12 3-9-12 28-0-0 4-0-4 -2-0-0 2-0-0 3-7-13 3-7-13 7-1-2 3-5-5 12-2-0 5-0-14 20-2-1 8-0-1 23-11-12 3-9-12 28-0-0 4-0-4 30-0-0 2-0-0 1- 9 - 8 4- 1 - 1 4 10 - 0 - 1 4 0- 1 1 - 4 10 - 0 - 1 4 4.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-3-12,0-1-8], [4:0-2-11,Edge], [5:0-1-12,Edge], [6:0-2-12,0-1-8], [11:0-5-0,0-1-4], [12:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.98 0.55 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.36 0.04 (loc) 11-12 9-11 8 l/defl >999 >930 n/a L/d 240 180 n/a PLATES MT20 Weight: 275 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B1: 2x6 SPF 1650F 1.5E WEBS 2x3 SPF No.2 *Except* W3,W4: 2x3 SPF Stud W6: 2x4 SPF No.2 W1,W9: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.(lb/size) 8 = 2863/0-5-8 (min. 0-2-4) 13 = 3641/0-5-8 (min. 0-2-14) Max Horz 13 = 243(LC 7) Max Uplift 8 = -179(LC 9) 13 = -301(LC 4) Max Grav 8 = 2863(LC 1) 13 = 3641(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5894/429, 3-4=-5927/486, 4-5=-1822/222, 5-6=-3034/212, 2-13=-3478/335, 6-8=-2793/221 BOT CHORD 12-13=-213/505, 11-12=-435/5515, 11-14=-250/2979, 10-14=-251/2978, 10-15=-255/2979, 9-15=-255/2979, 8-9=-263/450 WEBS 3-12=-1154/122, 4-9=-1959/248, 5-9=-82/1544, 2-12=-320/5148, 6-9=-274/1544, 4-11=-445/5328, 3-11=-2527/318 WEBS 3-12=-1154/122, 4-9=-1959/248, 5-9=-82/1544, 2-12=-320/5148, 6-9=-274/1544, 4-11=-445/5328, 3-11=-2527/318 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc , Except member 4-11 2x3 - 1 row at 0-7-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=179, 13=301. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3265 lb down and 309 lb up at 10-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-84, 2-3=-84, 3-4=-84, 4-5=-84, 5-6=-84 , 6-7=-84, 8-13=-20 Concentrated Loads (lb) Vert: 11=-3265(F) Job 304947-A Truss S1 Truss Type Monopitch Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:35 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-IUZ2kz5wQjraTh57CemjS04hZdrGKH_mY5CQcHz?nJY Scale = 1:27.6 T1 W5 B1 W3 W4 W1 W2 1 2 3 4 7 6 5 2x4 2x4 3x4 3x4 3x4 3x4 5-1-13 5-1-13 10-5-8 5-3-11 -2-0-0 2-0-0 5-1-13 5-1-13 10-5-8 5-3-11 1- 9 - 8 5- 3 - 5 4.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.39 0.25 0.60 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 7 = 728/0-5-8 (min. 0-1-8) 5 = 515/Mechanical Max Horz 7 = 167(LC 5) Max Uplift 7 = -109(LC 4) 5 = -63(LC 8) Max Grav 7 = 728(LC 1) 5 = 515(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-569/41, 2-7=-684/134 BOT CHORD 5-6=-69/478 WEBS 3-5=-551/87, 2-6=-2/491 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 7=109. LOAD CASE(S) Standard Job 304947-A Truss S2 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:36 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-mh7RxJ5YB1zR4qgJmMHy_Dctk0Dp3sCwnly_9kz?nJX Scale = 1:25.0 W1 T1 W3 B1 ST7 ST6 ST5 ST4 ST3 ST2 ST1 W2 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 3x4 3x4 -2-0-0 2-0-0 10-5-8 10-5-8 1- 9 - 8 5- 3 - 5 4.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.37 0.04 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 -0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 18-19. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 10-5-8. (lb) - Max Horz 19= 167(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 19, 11, 12, 13, 14, 15, 16, 17 except 18=-159(LC 5) Max Grav All reactions 250 lb or less at joint(s) 11, 12, 13, 14, 15, 16, 17, 18 except 19=417(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-413/23 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 11, 12, 13, 14, 15, 16, 17 except (jt=lb) 18=159. LOAD CASE(S) Standard Job 304947-A Truss S3 Truss Type Monopitch Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:38 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-j3EBM?7pjeD8K8qiunJQ3ehDaqt1XndDE3R4Dcz?nJV Scale = 1:19.1 T1 W3 B1 W1 W2 1 2 3 5 4 2x4 2x4 3x4 3x4 4-5-8 4-5-8 -1-0-0 1-0-0 4-5-8 4-5-8 2- 1 - 4 3- 7 - 1 3- 3 - 9 0- 3 - 8 3- 7 - 1 4.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.34 0.18 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.05 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W3: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 5 = 324/0-5-8 (min. 0-1-8) 4 = 207/0-1-8 (min. 0-1-8) Max Horz 5 = 104(LC 5) Max Uplift 5 = -54(LC 4) 4 = -41(LC 5) Max Grav 5 = 324(LC 1) 4 = 207(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-282/79 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. LOAD CASE(S) Standard Job 304947-A Truss U1 Truss Type Scissor Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:40 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-fSMxnh83FGUsZS_4?CLu93nS_eVU?dmViNwBIVz?nJT Scale = 1:66.1 T1 T1 B1 B1 W3 W1 W2 W1 W2 1 2 3 4 5 8 7 6 3x4 3x4 4x6 6x6 6x12 6x6 8-0-0 8-0-0 16-0-0 8-0-0 -2-6-0 2-6-0 8-0-0 8-0-0 16-0-0 8-0-0 18-6-0 2-6-0 2- 2 - 1 4 11 - 6 - 1 4 2- 2 - 1 4 4- 4 - 1 3 14.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [4:0-3-4,0-1-8], [6:0-1-12,0-1-8], [7:0-6-0,Edge], [8:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.80 0.44 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.36 0.07 (loc) 7-8 7-8 6 l/defl >999 >529 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3: 2x3 SPF Stud, W2: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-2-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 8 = 1039/0-5-8 (min. 0-1-10) 6 = 1039/0-5-8 (min. 0-1-10) Max Horz 8 = -310(LC 6) Max Uplift 8 = -59(LC 9) 6 = -59(LC 8) Max Grav 8 = 1039(LC 1) 6 = 1039(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1001/0, 3-4=-1001/71, 2-8=-1026/201, 4-6=-1026/140 BOT CHORD 7-8=-360/478 WEBS 3-7=-4/632, 2-7=0/451, 4-7=-183/518 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. LOAD CASE(S) Standard Job 304947-A Truss U2 Truss Type Scissor Structural Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:42 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-bqUiCNAJmtkaol8T7dOMEUsoaRFBTUro9hPIMNz?nJR Scale = 1:61.3 T1 T1 B1 B1 W3 W1 W2 W1 W2 ST8 ST7ST5 ST6 ST3 ST4 ST1 ST2 ST8 ST7 ST5 ST6 ST3 ST4 ST1 ST2 1 2 3 4 5 14 13 12 11 10 9 8 7 6 6x6 6x6 5x10 6x6 3x4 3x4 3x4 3x4 3x4 3x4 8-0-0 8-0-0 16-0-0 8-0-0 -2-6-0 2-6-0 8-0-0 8-0-0 16-0-0 8-0-0 18-6-0 2-6-0 2- 2 - 1 4 11 - 6 - 1 4 2- 2 - 1 4 4- 4 - 1 3 14.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [4:0-3-4,0-1-8], [19:0-0-15,0-1-0], [21:0-0-15,0-1-0], [23:0-0-15,0-1-0], [30:0-0-15,0-1-0], [32:0-0-15,0-1-0], [34:0-0-15,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.79 0.10 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.01 (loc) 10-11 10-11 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3: 2x3 SPF Stud, W2: 2x3 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 9-11-14 oc bracing: 11-12 10-0-0 oc bracing: 8-9. WEBS 1 Row at midpt 2-10, 4-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 16-0-0. (lb) - Max Horz 14=-310(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 10, 12, 13, 8, 7 except 14=-223(LC 9), 6=-229(LC 9) Max Grav All reactions 250 lb or less at joint(s) 11, 12, 13, 9, 8, 7 except 14=684(LC 1), 6=684(LC 1), 6=684(LC 1), 10=582(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-433/150, 3-4=-433/150, 2-14=-700/267, 4-6=-700/268 BOT CHORD 13-14=-358/413, 12-13=-359/413, 11-12=-350/427, 10-11=-370/428 WEBS 3-10=-357/0, 2-10=-199/287, 4-10=-202/288 WEBS 3-10=-357/0, 2-10=-199/287, 4-10=-202/288 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 12, 13, 8, 7 except (jt=lb) 14=223, 6=229. LOAD CASE(S) Standard Job 304947-A Truss U3 Truss Type Scissor Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:44 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-XDcSd2CaIU_I23IrE1QqJvx70FrNxJc5d?uPRGz?nJP Scale = 1:66.1 T1 T2 B1 B1 W3 W1 W2 W6 W4 W5 1 2 3 4 5 8 7 6 4x4 2x4 3x4 6x6 6x8 3x4 3x4 8-0-0 8-0-0 16-0-0 8-0-0 -2-6-0 2-6-0 8-0-0 8-0-0 14-0-0 6-0-0 16-0-0 2-0-0 2- 2 - 1 4 11 - 6 - 1 4 2- 2 - 1 4 4- 4 - 1 3 14.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [3:0-2-0,0-1-12], [4:0-1-8,0-1-8], [7:0-3-12,0-3-8], [8:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.79 0.50 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.40 0.09 (loc) 6-7 6-7 6 l/defl >999 >470 n/a L/d 240 180 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* T2: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W1: 2x4 SPF No.2, W2: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-8-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 8 = 1060/0-5-8 (min. 0-1-11) 6 = 800/0-5-8 (min. 0-1-8) Max Horz 8 = 260(LC 5) Max Uplift 8 = -61(LC 9) 6 = -49(LC 8) Max Grav 8 = 1060(LC 1) 6 = 800(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1036/42, 3-4=-949/126, 2-8=-1051/241 BOT CHORD 7-8=-344/413, 6-7=-79/560 WEBS 3-7=0/636, 2-7=0/435, 4-7=-117/264, 4-6=-1066/157 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. LOAD CASE(S) Standard Job 304947-A Truss V1 Truss Type Valley Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:45 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-0P9qqOCC3o69fDs2olx3s7UQDfHjgwIFrfdyziz?nJO Scale = 1:35.3 T1 T1 B1 ST1 1 2 3 43x4 4x4 3x4 2x3 0-0-3 0-0-3 7-9-14 7-9-11 3-10-15 3-10-15 7-9-14 3-10-15 0- 0 - 4 5- 1 0 - 7 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.32 0.11 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 274/7-9-9 (min. 0-1-8) 3 = 274/7-9-9 (min. 0-1-8) 4 = 208/7-9-9 (min. 0-1-8) Max Horz 1 = -118(LC 4) Max Uplift 1 = -52(LC 9) 3 = -46(LC 8) Max Grav 1 = 274(LC 1) 3 = 274(LC 1) 4 = 208(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard Job 304947-A Truss V2 Truss Type Valley Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:47 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-yoHbF4ESbPMtvX0QvAzXxYZpCS_L8rzXJy631bz?nJM Scale = 1:18.8 T1 T1 B1 ST1 1 2 3 4 3x4 4x4 3x4 2x3 0-0-3 0-0-3 4-8-8 4-8-5 2-4-4 2-4-4 4-8-8 2-4-4 0- 0 - 4 3- 6 - 6 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.09 0.04 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 157/4-8-2 (min. 0-1-8) 3 = 157/4-8-2 (min. 0-1-8) 4 = 119/4-8-2 (min. 0-1-8) Max Horz 1 = 67(LC 5) Max Uplift 1 = -30(LC 9) 3 = -26(LC 8) Max Grav 1 = 157(LC 1) 3 = 157(LC 1) 4 = 119(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard Job 304947-A Truss V3 Truss Type Valley Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:49 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-uBPLgmFi71ca8qAp1b0?0zfA4GfFclsqmGbA6Tz?nJK Scale = 1:8.1 T1 T1 B1 1 2 3 3x4 3x6 3x4 0-0-3 0-0-3 1-7-2 1-7-0 0-9-9 0-9-9 1-7-2 0-9-9 0- 0 - 4 1- 2 - 6 0- 0 - 4 18.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-13] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.01 0.01 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 55/1-6-13 (min. 0-1-8) 3 = 55/1-6-13 (min. 0-1-8) Max Horz 1 = 17(LC 5) Max Uplift 1 = -4(LC 9) 3 = -4(LC 8) Max Grav 1 = 55(LC 1) 3 = 55(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard Job 304947-A Truss V4 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:51 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-qZX65RHzfesIN8KB802T5OkT93JQ4d27Ea4GAMz?nJI Scale = 1:54.3 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 69103x4 4x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 12-8-1 12-7-15 6-4-1 6-4-1 12-8-1 6-4-1 0- 0 - 4 9- 6 - 1 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.22 0.16 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST2: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-7-12. (lb) - Max Horz 1=-197(LC 4) Max Uplift All uplift 100 lb or less at joint(s) except 1=-125(LC 6), 5=-107(LC 7), 8=-299(LC 8), 6=-299(LC 9) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=344(LC 18), 8=495(LC 15), 6=494(LC 16) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-280/196, 2-3=-262/114, 3-4=-262/101, 4-5=-267/174 WEBS 2-8=-378/340, 4-6=-378/340 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 lb uplift at joint 1, 107 lb uplift at joint 5, 299 lb uplift at joint 8 and 299 lb uplift at joint 6. LOAD CASE(S) Standard Job 304947-A Truss V5 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:53 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-nyesW7IDBF60dSUaGQ4xApppUt?6XWiQhuZNFFz?nJG Scale = 1:48.8 T1 T1 B1 ST2 ST1 ST11 2 3 4 5 8 7 69 103x4 4x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-3 0-0-3 11-4-1 11-3-15 5-8-1 5-8-1 11-4-1 5-8-1 0- 0 - 4 8- 6 - 1 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.24 0.14 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST2: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 11-3-12. (lb) - Max Horz 1=-175(LC 4) Max Uplift All uplift 100 lb or less at joint(s) except 1=-154(LC 6), 5=-138(LC 7), 8=-298(LC 8), 6=-298(LC 9) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=325(LC 18), 8=478(LC 15), 6=477(LC 16) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-290/199, 2-3=-263/103, 3-4=-263/92, 4-5=-278/179 WEBS 2-8=-384/346, 4-6=-384/346 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 154 lb uplift at joint 1, 138 lb uplift at joint 5, 298 lb uplift at joint 8 and 298 lb uplift at joint 6. LOAD CASE(S) Standard Job 304947-A Truss V6 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:55 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-jLmcwpKTjtMksldzNr6PGEv9qhhv?RVj9C2UK7z?nJE Scale = 1:43.2 T1 T1 B1 ST2 ST1 ST11 2 3 4 5 8 7 69 103x4 4x4 3x4 2x3 3x5 2x3 3x5 2x3 0-0-3 0-0-3 10-0-1 9-11-15 5-0-1 5-0-1 10-0-1 5-0-1 0- 0 - 4 7- 6 - 1 0- 0 - 4 18.00 12 Plate Offsets (X,Y)-- [6:0-2-12,0-1-8], [8:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-S 0.24 0.12 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 9-11-12. (lb) - Max Horz 1=-153(LC 4) Max Uplift All uplift 100 lb or less at joint(s) except 1=-237(LC 6), 5=-224(LC 7), 8=-355(LC 8), 6=-355(LC 9) Max Grav All reactions 250 lb or less at joint(s) except 1=313(LC 8), 5=305(LC 9), 7=286(LC 15), 8=551(LC 15), 6=550(LC 16) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-355/236, 2-3=-270/91, 3-4=-270/82, 4-5=-345/221 WEBS 2-8=-467/421, 4-6=-466/421 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 237 lb uplift at joint 1, 224 lb uplift at joint 5, 355 lb uplift at joint 8 and 355 lb uplift at joint 6. LOAD CASE(S) Standard Job 304947-A Truss V7 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:56 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-BXK_89L5TAVbUvC9xZeeoRRJ341UkvHsNso1sZz?nJD Scale = 1:33.4 T1 T1 B1 ST1 1 2 3 43x4 4x4 3x4 2x3 0-0-3 0-0-3 7-4-9 7-4-6 3-8-5 3-8-5 7-4-9 3-8-5 0- 0 - 4 5- 6 - 7 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.28 0.10 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 258/7-4-4 (min. 0-1-8) 3 = 258/7-4-4 (min. 0-1-8) 4 = 196/7-4-4 (min. 0-1-8) Max Horz 1 = -111(LC 4) Max Uplift 1 = -49(LC 9) 3 = -43(LC 8) Max Grav 1 = 258(LC 1) 3 = 258(LC 1) 4 = 196(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 1 and 43 lb uplift at joint 3. LOAD CASE(S) Standard Job 304947-A Truss V8 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:58 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-7vSlZrMM?olJjDMY3_g6tsXhkuk1Cql9rAH8wSz?nJB Scale = 1:17.3 T1 T1 B1 ST1 1 2 3 4 3x4 4x4 3x4 2x3 0-0-3 0-0-3 4-3-4 4-3-1 2-1-10 2-1-10 4-3-4 2-1-10 0- 0 - 4 3- 2 - 7 0- 0 - 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.07 0.03 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 140/4-2-14 (min. 0-1-8) 3 = 140/4-2-14 (min. 0-1-8) 4 = 107/4-2-14 (min. 0-1-8) Max Horz 1 = -60(LC 4) Max Uplift 1 = -27(LC 9) 3 = -24(LC 8) Max Grav 1 = 140(LC 1) 3 = 140(LC 1) 4 = 107(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 1 and 24 lb uplift at joint 3. LOAD CASE(S) Standard Job 304947-A Truss V9 Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:06:59 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-b607mBN_m5tALNxkchBLQ43q?I39xGbI3q0hTuz?nJA Scale = 1:17.5 T1 W1 B1 ST1 1 2 3 5 4 3x4 2x4 2x4 2x3 2x3 7-6-10 7-6-10 0- 0 - 4 3- 1 - 1 2 5.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.23 0.10 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 89/7-6-0 (min. 0-1-8) 4 = 162/7-6-0 (min. 0-1-8) 5 = 444/7-6-0 (min. 0-1-8) Max Horz 1 = 91(LC 5) Max Uplift 4 = -15(LC 8) 5 = -65(LC 8) Max Grav 1 = 89(LC 1) 4 = 162(LC 1) 5 = 444(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-359/116 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint 4 and 65 lb uplift at joint 5. LOAD CASE(S) Standard Job 304947-A Truss V10L Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:01 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-YU7tBsPEIj7uag56k6DpVV86x5jnP8KbX8VoXnz?nJ8 Scale = 1:62.2 T1 W1 B1 B2 B3 ST3 ST2 ST11 2 3 4 5 6 12 11 10 9 8 73x4 2x4 2x4 2x4 2x4 2x4 2x3 2x3 2x3 2x3 2x3 2x3 0-4-3 0-4-3 5-1-1 4-8-14 7-6-9 2-5-8 5-1-1 5-1-1 7-6-9 2-5-8 10 - 9 - 1 0 0- 0 - 1 9- 9 - 9 0- 0 - 1 1- 0 - 0 1- 0 - 1 18.00 12 0.02 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.46 0.16 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.04 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST3: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 7-2-6. (lb) - Max Horz 1= 285(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 11 except 1=-211(LC 6), 7=-139(LC 7), 9=-114(LC 8), 12=-130(LC 8) Max Grav All reactions 250 lb or less at joint(s) 7, 10, 9, 8, 11, 12 except 1=332(LC 5) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-400/301, 2-3=-326/238, 3-4=-278/198 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 11 except (jt=lb) 1=211, 7=139, 9=114, 12=130. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 7, 10, 9, 8, 11, 12. LOAD CASE(S) Standard Job 304947-A Truss V11L Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:02 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-0hhGOCPs30FkCqgJIpl22ihGlV0B8cHlmoFM3Dz?nJ7 Scale = 1:59.9 T1 W2 B1 B2 ST1 W1 1 2 3 4 7 56 8 9 10 12113x4 2x4 2x4 5x5 2x3 2x3 2x3 0-0-3 0-0-3 4-4-4 4-4-2 4-7-12 0-3-8 7-0-12 2-5-0 4-4-4 4-4-4 4-7-12 0-3-8 7-0-12 2-5-0 0- 0 - 4 10 - 7 - 4 0- 0 - 1 10 - 3 - 1 2 0- 0 - 1 0- 3 - 6 18.00 12 0.02 12 Plate Offsets (X,Y)-- [6:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.52 0.34 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W1: 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 6-0-0 oc bracing: 6-7 WEBS 1 Row at midpt 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 7-0-10. (lb) - Max Horz 1= 288(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 5 except 1=-120(LC 4), 8=-142(LC 7), 7=-120(LC 8) Max Grav All reactions 250 lb or less at joint(s) 8, 6, 5 except 1=323(LC 16), 7=346(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-349/177, 2-3=-305/143 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 1=120, 8=142, 7=120. 6) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 8, 6, 5 , 7. LOAD CASE(S) Standard Job 304947-A Truss V12L Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:04 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-y3p0puR6beVSR8phPEnW77mcFJm_cWD1D6kS86z?nJ5 Scale = 1:56.7 T1 W1 B1 B2 B3 ST1 1 2 3 4 8 7 6 53x4 2x4 2x4 2x4 2x4 2x4 2x3 2x3 0-0-3 0-0-3 4-1-12 4-1-10 6-6-12 2-5-0 4-1-12 4-1-12 6-6-12 2-5-0 0- 0 - 4 10 - 3 - 1 4 0- 5 - 1 2 0- 5 - 1 2 18.00 12 0.02 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.52 0.12 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.01 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 6-6-10. (lb) - Max Horz 1= 279(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-160(LC 6), 5=-142(LC 7), 7=-187(LC 8), 8=-170(LC 8) Max Grav All reactions 250 lb or less at joint(s) 5, 7, 6 except 1=282(LC 5), 8=271(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-341/262 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint 1, 142 lb uplift at joint 5, 187 lb uplift at joint 7 and 170 lb uplift at joint 8. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 8. LOAD CASE(S) Standard Job 304947-A Truss V13L Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:06 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-uSxmEaTN7FlAhRz4Xfp_CYsyl6Qi4QyKgQDZC_z?nJ3 Scale = 1:56.3 T1 W1 B1 B2 B3 ST11 2 3 4 8 7 6 5 3x4 2x4 2x4 2x4 2x4 2x4 2x3 2x3 0-0-3 0-0-3 3-7-12 3-7-10 6-0-12 2-5-0 3-7-12 3-7-12 6-0-12 2-5-0 0- 0 - 4 10 - 3 - 1 4 1- 2 - 1 2 1- 2 - 1 2 18.00 12 0.03 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.52 0.24 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.08 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 6-0-10. (lb) - Max Horz 1= 273(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-154(LC 6), 5=-141(LC 7), 7=-212(LC 8), 8=-140(LC 8) Max Grav All reactions 250 lb or less at joint(s) 5, 7, 6, 8 except 1=256(LC 5) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-310/238 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 154 lb uplift at joint 1, 141 lb uplift at joint 5, 212 lb uplift at joint 7 and 140 lb uplift at joint 8. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 8. LOAD CASE(S) Standard Job 304947-A Truss V14L Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:07 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-MeV9SwT?uZt1IbYG4NKDlmO7VWk_puOUv4y7lRz?nJ2 Scale = 1:56.1 T1 W1 B1 B2 B3 ST11 2 3 4 8 7 6 5 3x4 2x4 2x4 2x4 2x4 2x4 2x3 2x3 0-0-3 0-0-3 3-2-1 3-1-15 5-7-1 2-5-0 3-2-1 3-2-1 5-7-1 2-5-0 0- 0 - 4 10 - 3 - 1 4 1- 1 1 - 4 1- 1 1 - 4 18.00 12 0.03 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.52 0.36 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.19 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 5-6-15. (lb) - Max Horz 1= 267(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 1=-147(LC 6), 5=-141(LC 7), 7=-238(LC 8), 8=-115(LC 8) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 6, 8 FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-308/214 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 147 lb uplift at joint 1, 141 lb uplift at joint 5, 238 lb uplift at joint 7 and 115 lb uplift at joint 8. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 8. LOAD CASE(S) Standard Job 304947-A Truss V15R Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:09 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-J1cvsbVFPA7lYvifCnNhqBUa2KUvHnGnNNRDpJz?nJ0 Scale = 1:39.7 T1 W1 B1 ST3 ST2 ST11 2 3 4 5 9 8 7 63x4 2x4 2x4 2x3 2x3 2x3 2x3 2x3 2x3 5-4-9 5-4-9 7- 6 - 9 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.07 0.01 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 5-0-6. (lb) - Max Horz 1= 210(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 6, 9 except 1=-121(LC 6), 7=-104(LC 8), 8=-107(LC 8) Max Grav All reactions 250 lb or less at joint(s) 6, 7, 8, 9 except 1=295(LC 8) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-358/164, 2-3=-269/125 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 9 except (jt=lb) 1=121, 7=104, 8=107. LOAD CASE(S) Standard Job 304947-A Truss V16R Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:11 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-FQkfHHWVxnOTnDs1JCP9vcZky77IliI3qhwKuCz?nJ_ Scale = 1:36.5 T1 W1 B1 1 2 33x4 2x4 2x4 4-10-9 4-10-9 0- 0 - 4 7- 3 - 1 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.87 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 234/4-10-7 (min. 0-1-8) 3 = 233/4-10-7 (min. 0-1-8) Max Horz 1 = 197(LC 7) Max Uplift 1 = -47(LC 4) 3 = -139(LC 5) Max Grav 1 = 291(LC 16) 3 = 294(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 3=139. LOAD CASE(S) Standard Job 304947-A Truss V17R Truss Type Valley Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:12 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-jcI2VdX8i5WKPMREtwwOSp6yTXUCU9YD3LgtPez?nIz Scale = 1:33.4 T1 W1 B1 1 2 33x4 2x4 2x4 4-5-1 4-5-1 0- 0 - 4 6- 7 - 1 0 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.70 0.17 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 1 = 210/4-4-15 (min. 0-1-8) 3 = 209/4-4-15 (min. 0-1-8) Max Horz 1 = 177(LC 5) Max Uplift 1 = -43(LC 4) 3 = -124(LC 5) Max Grav 1 = 262(LC 16) 3 = 264(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 3=124. LOAD CASE(S) Standard Job 304947-A Truss W1 Truss Type Monopitch Qty 7 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:14 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-f_QowJZOEim1egac?LysXEBKhL70y0?WWf9_TXz?nIx Scale = 1:58.8 T1 W3 B1 W1 W21 2 3 5 4 2x4 2x4 4x4 3x4 -1-11-6 1-11-6 5-4-2 5-4-2 3- 4 - 1 3 11 - 5 - 0 11 - 1 - 8 0- 3 - 8 11 - 5 - 0 18.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.46 0.27 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.10 -0.00 (loc) 4-5 4-5 4 l/defl >999 >606 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W3: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 5 = 472/0-3-8 (min. 0-1-8) 4 = 230/0-1-8 (min. 0-1-8) Max Horz 5 = 278(LC 8) Max Uplift 4 = -349(LC 8) Max Grav 5 = 472(LC 1) 4 = 343(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-421/43 BOT CHORD 4-5=-294/164 WEBS 2-4=-193/346 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=349. LOAD CASE(S) Standard Job 304947-A Truss W2 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:16 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-cNXYK?aemK0lt_k?6m?KcfGao8fvQvIp_ze5YPz?nIv Scale = 1:54.5 T2 W4 B1 W1 W2 W3 ST3 ST2 ST1 T1 1 2 3 4 6 515 16 6x10 MT18HS 5x5 3x5 3x5 0-1-12 0-1-12 2-0-0 1-10-4 4-0-0 2-0-0 5-3-15 1-3-15 5-4-2 0-0-3 -1-11-6 1-11-6 5-4-2 5-4-2 3- 4 - 1 3 10 - 1 0 - 1 1 18.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-8], [5:Edge,0-2-12], [7:0-0-5,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 9.0 0.0 * 12.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.87 0.95 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.34 -0.00 (loc) 5-6 5-6 5 l/defl >383 >181 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 53 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x3 SPF Stud *Except* W4: 2x3 SPF No.2, W1: 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD 2-0-0 oc purlins, except end verticals (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 7-9-12 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.(lb/size) 6 = 1262/0-3-8 (min. 0-2-0) 5 = 640/Mechanical Max Horz 6 = 423(LC 8) Max Uplift 6 = -56(LC 4) 5 = -568(LC 8) Max Grav 6 = 1262(LC 1) 5 = 694(LC 29) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-406/103, 3-4=-272/244, 4-5=-349/299, 2-6=-707/16 BOT CHORD 6-15=-447/247, 15-16=-447/247, 5-16=-447/247 WEBS 2-5=-286/516 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are MT20 plates unless otherwise indicated. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 5=568. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 263 lb down and 51 lb up at 0-1-12, and 222 lb down and 72 lb up at 2-0-0, and 222 lb down and 72 lb up at 4-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-139, 2-4=-139, 5-6=-38 Concentrated Loads (lb) Vert: 6=-263 15=-222 16=-222 Job 304947-A Truss X1 Truss Type Monopitch Qty 9 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:17 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-4Z5xYKbGXd8cV8JBgTWZ9tptzYAq9JQyCdNe4sz?nIu Scale = 1:25.2 T1 W6 B1 W4 W5 W1 W3W21 2 3 4 5 9 8 7 6 2x4 3x8 3x4 3x4 3x4 3x4 2x4 0-8-0 0-8-0 5-9-9 5-1-9 10-5-8 4-7-15 -1-0-0 1-0-0 5-9-9 5-9-9 10-5-8 4-7-15 0- 1 0 - 4 4- 9 - 5 4.50 12 Plate Offsets (X,Y)-- [2:0-0-8,0-1-4], [9:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.33 0.20 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.00 (loc) 7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 481/Mechanical 8 = 678/0-3-8 (min. 0-1-8) Max Horz 8 = 121(LC 8) Max Uplift 6 = -75(LC 8) 8 = -63(LC 4) Max Grav 6 = 481(LC 1) 8 = 678(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-592/10 BOT CHORD 6-7=-84/488 WEBS 4-6=-561/96, 3-7=0/442, 3-8=-581/106 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8. LOAD CASE(S) Standard Job 304947-A Truss X2 Truss Type Roof Special Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:19 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-0yDhz0dX3FOKkRTanuY1EIuCMMsKdICFgxsl9kz?nIs Scale = 1:18.7 T1 W4 B1 W1 W3W21 2 3 4 7 6 5 3x4 3x8 3x4 2x4 3x4 0-8-0 0-8-0 6-5-8 5-9-8 -1-0-0 1-0-0 6-5-8 6-5-8 0- 1 0 - 4 3- 3 - 5 2- 1 1 - 1 3 0- 3 - 8 3- 3 - 5 4.50 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-4], [7:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.40 0.20 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W4: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 478/0-3-8 (min. 0-1-8) 5 = 260/0-1-8 (min. 0-1-8) Max Horz 6 = 101(LC 5) Max Uplift 6 = -70(LC 4) 5 = -34(LC 8) Max Grav 6 = 478(LC 1) 5 = 260(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-437/152 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. LOAD CASE(S) Standard Job 304947-A Truss X3 Truss Type GABLE Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:21 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-yLLROienbse2_ldyvJaVJjzYZ9XU5BeY7FLsDdz?nIq Scale = 1:18.7 T1 W4 B1 W1 W3W2 ST2 ST1 1 2 3 4 7 6 5 3x4 3x8 3x4 2x4 2x4 2x4 2x4 2x4 4x4 0-8-0 0-8-0 6-5-8 5-9-8 -1-0-0 1-0-0 6-5-8 6-5-8 0- 1 0 - 4 3- 3 - 5 2- 1 1 - 1 3 0- 3 - 8 3- 3 - 5 4.50 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-4], [7:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 9.0 0.0 * 12.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.42 0.22 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.07 0.00 (loc) 5-6 5-6 5 l/defl >999 >930 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud *Except* W4: 2x4 SPF No.2 OTHERS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6 = 512/0-3-8 (min. 0-1-8) 5 = 281/0-1-8 (min. 0-1-8) Max Horz 6 = 101(LC 7) Max Uplift 6 = -70(LC 4) 5 = -34(LC 8) Max Grav 6 = 512(LC 1) 5 = 281(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-450/152 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. LOAD CASE(S) Standard Job 304947-A Truss X4 Truss Type Monopitch Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:23 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-ujSCoOg16TumD3mL0kdzO83yfzFsZ6xqbZqzIVz?nIo Scale = 1:18.7 T1 W4 B1 B2 B3 W1 W3W21 2 3 4 5 10 9 8 7 6 2x4 2x4 3x8 2x4 2x4 3x4 3x4 2x4 0-8-0 0-8-0 4-11-8 4-3-8 5-5-8 0-6-0 6-5-8 1-0-0 -1-0-0 1-0-0 4-11-8 4-11-8 6-5-8 1-6-0 0- 1 0 - 4 3- 3 - 5 2- 1 - 7 1- 1 - 1 4 4.50 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-4], [10:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MS 0.19 0.10 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 -0.00 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 7-8. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 7 = 363/0-5-8 (min. 0-1-8) 9 = 379/0-3-8 (min. 0-1-8) Max Horz 9 = 87(LC 5) Max Uplift 7 = -59(LC 5) 9 = -59(LC 4) Max Grav 7 = 363(LC 1) 9 = 379(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 4-7=-298/76 WEBS 3-9=-279/89 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 9. LOAD CASE(S) Standard Job 304947-A Truss Y1 Truss Type Monopitch Qty 3 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:24 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-Nw0a0kgftn0drCLXaR8CxLb2DNU7IaW_pDaWqyz?nIn Scale = 1:62.8 T1 W1 B1 1 2 6 3 5 7 48 2x4 3x5 2x4 5-7-7 15 -8 -4 -1-11-8 1-11-8 6-6-0 6-6-0 0- 6 - 1 4 10 - 3 - 1 4 10 - 0 - 6 0- 3 - 8 10 - 3 - 1 4 18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.46 0.54 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.15 -0.27 0.02 (loc) 4-7 4-7 2 l/defl >520 >285 n/a L/d 240 180 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2 = 520/0-5-8 (min. 0-1-8) 4 = 305/0-1-8 (min. 0-1-8) Max Horz 2 = 364(LC 8) Max Uplift 4 = -234(LC 8) Max Grav 2 = 520(LC 1) 4 = 436(LC 15) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-640/407, 3-6=-268/191, 3-4=-270/232 BOT CHORD 5-7=-414/164 WEBS 2-5=-275/57, 6-7=-485/657 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=234. LOAD CASE(S) Standard Job 304947-A Truss Y2 Truss Type MONOPITCH SUPPORTED Qty 1 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:25 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-r6ayD4hHe58UTMwk89fRTZ8ADnyU1zF72tJ3MOz?nIm Scale = 1:58.6 T2 W1 B1 ST4 ST3 ST2 ST1 HW1T1 1 2 3 4 5 6 7 8 13 12 11 10 9 3x4 3x4 3x4 6-6-0 6-6-0 -1-11-8 1-11-8 6-6-0 6-6-0 0- 6 - 1 4 9- 9 - 9 18.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-3], [2:0-2-15,0-4-6], [2:0-1-8,0-1-0], [3:0-1-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 10.0 0.0 * 13.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-2-0 1.15 1.15 NO MNSRC2015/TPI2007 CSI. TC BC WB Matrix-P 0.70 0.02 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.00 -0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x3 SPF Stud *Except* ST4: 2x3 SPF No.2 WEDGE Left: 2x6 SPF 1650F 1.5E BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals (Switched from sheeted: Spacing > 2-0-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9 REACTIONS. All bearings 6-4-8. (lb) - Max Horz 2= 553(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 9, 2, 12 except 10=-165(LC 8), 11=-167(LC 8), 13=-133(LC 1) Max Grav All reactions 250 lb or less at joint(s) 9, 13 except 2=680(LC 1), 10=281(LC 15), 11=281(LC 15), 12=310(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-550/211, 3-4=-520/224, 4-5=-519/279, 5-6=-421/201 WEBS 5-12=-256/113 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2, 12 except (jt=lb) 10=165, 11=167, 13=133. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job 304947-A Truss Z1 Truss Type Monopitch Qty 4 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:27 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-nVijeljYAiPBig46FZhvZ_Dciab3VwJQWBoARGz?nIk Scale = 1:25.1 T1 B1 B2 W1 HW1 1 2 10 3 7 4 9 11 5 8 6 3x4 3x5 4x4 2x3 4-0-15 4-0-15 8-1-14 4-0-15 -1-0-0 1-0-0 4-0-15 4-0-15 8-1-14 4-0-15 0- 7 - 6 4- 7 - 1 2 4- 7 - 1 2 6.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-7], [2:0-0-1,0-3-7], [2:0-0-0,0-0-1], [4:0-1-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.31 0.14 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.03 0.02 (loc) 6 5-11 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 4 = 3/4-0-15 (min. 0-1-8) 2 = 167/0-5-8 (min. 0-1-8) 5 = 683/4-0-15 (min. 0-1-8) Max Horz 2 = 123(LC 8) Max Uplift 4 = -77(LC 3) 5 = -94(LC 8) Max Grav 4 = 3(LC 1) 2 = 167(LC 1) 5 = 683(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-10=-117/280 BOT CHORD 5-8=-256/0, 6-8=-324/55, 4-6=-252/18 WEBS 3-5=-370/115 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 5) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 4, 5. LOAD CASE(S) Standard Job 304947-A Truss Z2 Truss Type Monopitch Structural Gable Qty 2 Ply 1 Roof Job Reference (optional) 8.220 s Jun 14 2018 MiTek Industries, Inc. Tue Jul 3 12:07:28 2018 Page 1 Villaume Industries, St Paul, MN ID:?rIuPgXyo3KRqmSS1F3L2Gz0AmL-FhG5s5kAx0X2KqfJpHC95Bmo0_wlENzakrYkzjz?nIj Scale: 1/2"=1' T1 B1 B2 W1 HW1 ST4 ST3 ST2 ST1 1 2 18 3 15 4 17 19 9 8 7 6 5 14 16 20 3x4 3x5 4x4 4-0-15 4-0-15 8-1-14 4-0-15 -1-0-0 1-0-0 4-0-15 4-0-15 8-1-14 4-0-15 0- 7 - 6 4- 7 - 1 2 4- 7 - 1 2 6.00 12 14.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-7], [2:0-0-1,0-3-7], [2:0-0-0,0-0-1], [4:0-1-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES MNSRC2015/TPI2007 CSI. TC BC WB Matrix-MP 0.21 0.24 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.02 (loc) 1 1-2 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF Stud OTHERS 2x3 SPF Stud WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 8-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 8-0-12. (lb) - Max Horz 4= 123(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 5, 6 except 7=-314(LC 8), 8=-124(LC 1) Max Grav All reactions 250 lb or less at joint(s) 4, 5, 6, 8 except 7=577(LC 1), 9=357(LC 1) FORCES.(lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-18=-54/252, 3-18=-75/253 BOT CHORD 6-7=-306/242, 5-6=-295/145, 5-14=-311/210 WEBS 3-7=-292/107, 18-19=-334/54 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x3 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6 except (jt=lb) 7=314, 8=124. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 4, 5, 6. LOAD CASE(S) Standard Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jun-22 14:58:26 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Load Short Form June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor: Lakeville, mn Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F) AverageConstruction quality7572Inside db (°F) 0Fireplaces1387Design TD (°F) M-Daily range 5030Inside humidity (%) 3134Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model EL195UH090XE48C-*Cond XC16S048-230-04 AHRI ref 4675033 Coil C33-48C+EL195UH090XE48C*+TDR+TXV AHRI ref 7622116 Efficiency 95 AFUE Efficiency 11.7 EER, 15 SEER Heating input Btuh88000 Sensible cooling Btuh31150 Heating output Btuh85000 Latent cooling Btuh13350 Temperature rise °F50 Total cooling Btuh44500 Actual air flow cfm1593 Actual air flow cfm1483 Air flow factor cfm/Btuh0.020 Air flow factor cfm/Btuh0.053 Static pressure in H2O0.50 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) lower level 1519 22779 6033 463 318 main floor 1519 29561 11954 601 630 second 1918 25969 10157 528 535 Entire House d 4956 78308 28144 1593 1483 Other equip loads 4818 2382 Equip. @ 0.93 RSM 28358 Latent cooling 7184 TOTALS 4956 83126 35542 1593 1483 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jun-22 14:58:26 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Loads for Multiple Orientations June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor: Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude: Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) )M(18-Daily range (°F) 72-Wet bulb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)25598 22639 27233 28358 26133 21142 24491 26028 Latent Load (Btuh)7184 7184 7184 7184 7184 7184 7184 7184 Total Load (Btuh)32783 29823 34418 35542 33318 28326 31675 33212 Heating AVF (cfm)1593 1593 1593 1593 1593 1593 1593 1593 Cooling AVF (cfm)1483 1483 1483 1483 1483 1483 1483 1483 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 10000 20000 30000 40000 N NE E SE S SW W NW Front Door faces SoutheastCurrent Orientation: Front Door faces SoutheastHighest Cooling Load: Bold/italic values have been manually overridden 2018-Jun-22 14:58:28 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Building Analysis June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Design Conditions Location:CoolingHeatingIndoor:7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation:5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F)SimplifiedMethod)M(18-Daily range (°F) AverageConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilingsFloors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 25.9215184.5Walls 28.52366227.8Glazing 0.863930.4Doors 4.133931.7Ceilings 7.562023.23.2Floors 27.5228935.4Infiltration 00Ducts00Piping00Humidification5.84818Ventilation0Adjustments100.083126Total Cooling Walls Glazing Other Ceilings Infiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 10.331370.7Walls 58.71792321.1Glazing 0.61878.9Doors 6.319091.0Ceilings 0.3940.0Floors 5.717430.4Infiltration 00Ducts7.82382Ventilation10.33150Internal gains 00Blower0Adjustments100.030525Total Latent Cooling Load = 7184 BtuhOverall U-value = 0.068 Btuh/ft²-°F ERROR: negative wall area in lower level - check windows. 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Component Constructions June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) AverageConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1420.938675.6521.00.065153n 2090.9312785.6521.00.065226e 3610.9322035.6521.00.065390s 2920.9317815.6521.00.065315w 10040.9361285.6521.00.0651084all 15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15 ins, 10" thk 280.0813053.8715.00.042337n 510.1117873.9515.00.042453e 210.0810683.8515.00.042277s 1000.1134363.7115.00.042926all IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 4550.8224194.3520.00.050556n 2680.8214244.3520.00.050327e 5130.8227324.3520.00.050628s 5970.8231744.3520.00.050730w 18320.8297484.3520.00.0502241all PartitionsIECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2020.4022054.3520.00.050507 Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 1757.7163327.800.32023n 1757.7163327.800.32023n 937.7133427.800.32012n 117621.9149927.800.32054e 176421.9224827.800.32081e 129013.0277027.800.320100s 29513.063327.800.32023s 261821.9333627.800.320120w 217421.9277027.800.320100w 284621.9362627.800.320130w 1260719.01848327.800.320664all 10A-m: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 64215.3116927.800.32042e 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 2G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE 10B-m: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 3549.07108627.800.32039s 137721.9175427.800.32063w 91821.9116927.800.32042w 264818.4400927.800.320144all Doors 11N0: Door, mtl eps core type 1878.9163930.48.70.35021n Ceilings16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 19090.9833931.7450.00.0201950 Floors19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul 940.226371.4830.00.049431 22D-10tpm: Bg floor, heavy dry or light damp soil, full ext ins cov, on grade depth, r-10 edge ins, r-10 ins 00556529.810.00.343187 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 3G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Component Constructions June 22 2018Date:lower level By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) AverageConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15 ins, 10" thk 280.0813053.8715.00.042337n 510.1117873.9515.00.042453e 210.0810683.8515.00.042277s 1000.1134363.7115.00.042926all IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 980.825224.3520.00.050120n 1470.827834.3520.00.050180s 3700.8219664.3520.00.050452w 6150.8232714.3520.00.050752all Partitions (none) Windowsmarvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 1757.7163327.800.32023n 29513.063327.800.32023s 217421.9277027.800.320100w 264418.2403727.800.320145all 1D-c2omd: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 91821.9116927.800.32042w Doors (none) Ceilings (none) Floors22D-10tpm: Bg floor, heavy dry or light damp soil, full ext ins cov, on grade depth, r-10 edge ins, r-10 ins 00556529.810.00.343187 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 4G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Component Constructions June 22 2018Date:main floor By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) AverageConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1420.938675.6521.00.065153n 2090.9312785.6521.00.065226e 3610.9322035.6521.00.065390s 2920.9317815.6521.00.065315w 10040.9361285.6521.00.0651084all Partitions IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2020.4022054.3520.00.050507 Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 1757.7163327.800.32023n 117621.9149927.800.32054e 129013.0277027.800.320100s 261821.9333627.800.320120w 526017.8823827.800.320296all 10A-m: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 64215.3116927.800.32042e 10B-m: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 3549.07108627.800.32039s 137721.9175427.800.32063w 173017.0284027.800.320102all Doors 11N0: Door, mtl eps core type 1878.9163930.48.70.35021n Ceilings16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 320.98571.7450.00.02033 Floors(none) 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 5G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Component Constructions June 22 2018Date:second By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) AverageConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 3560.8218974.3520.00.050436n 2680.8214244.3520.00.050327e 3660.8219494.3520.00.050448s 2270.8212084.3520.00.050278w 12170.8264774.3520.00.0501489all Partitions (none) Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 937.7133427.800.32012n 176421.9224827.800.32081e 284621.9362627.800.320130w 470321.1620827.800.320223all Doors(none) Ceilings16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 18770.9833371.7450.00.0201918 Floors 19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul 940.226371.4830.00.049431 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jun-22 14:58:28Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:Project Summary June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor:Lakeville, mn Notes: Design Information Minneapolis-St Paul Int'l Arp, MN, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-15 Outside db °F88Inside db °F72 Inside db °F75Design TD °F87 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh78308 Structure Btuh28144DuctsBtuh0DuctsBtuh0Central vent (SER=70% 173 cfm)Btuh4818 Central vent (SER=0% 173 cfm)2382 BtuhHeat recovery Heat recoveryHumidificationBtuh0Blower Btuh0PipingBtuh0Equipment load Btuh83126 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh28358 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh3614DuctsBtuh0Central vent (173 cfm)Btuh3571CoolingHeatingHeat recovery49564956Area (ft²)Equipment latent load Btuh71843998739987Volume (ft³)Air changes/hour 0.190.37 Equipment Total Load (Sen+Lat)Btuh35542Equiv. AVF (cfm)127247 Req. total capacity at 0.70 SHR ton3.4 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make LennoxTradeLENNOXTradeLENNOXModelEL195UH090XE48C-*Cond XC16S048-230-04AHRI ref 4675033 Coil C33-48C+EL195UH090XE48C*+TDR+TXVAHRI ref 7622116Efficiency95 AFUE Efficiency 11.7 EER, 15 SEERHeating input Btuh88000 Sensible cooling Btuh31150Heating output Btuh85000 Latent cooling Btuh13350Temperature rise °F50 Total cooling Btuh44500Actual air flow cfm1593 Actual air flow cfm1483Air flow factor cfm/Btuh0.020 Air flow factor cfm/Btuh0.053Static pressure in H2O0.50 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.81 Bold/italic values have been manually overridden 2018-Jun-22 14:58:28 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 G:\binder heating\perron Residence.rup Calc = MJ8 Front Door faces: SE Job:AED Assessment June 22 2018Date:Entire House By: Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com Project Information Perron Residence, Binder Heating and AirFor: Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F))M(18-Daily range (°F) 72-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 43.8%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 2025 Btuh (PFG - 1.3*AFG) Job:Right-J® Worksheet June 22 2018Date:Entire House By:Tony Ledo Phone: 763-229-4252 Email: Tonyledo2012@gmail.com 1 Room name Entire House lower level 2 Exposed wall 539.0 ft 186.5 ft3Room height 9.5 dft 10.0 heat/coolft 4 Room dimensions ft1519.0x1.0 5 Room area 4955.6 ft²1519.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 5.655.65 0.930.93 176 153 867 142 0 0 0 0.GG marvin fiberglass in 0.320marvin fiberglass in 0.320 nn 27.8427.84 7.717.71 23 0 633 175 0 0 0 0.WW 15B-15sfc-815B-15sfc-8 0.0590.059 nn 3.873.87 0.080.08 360 337 1305 28 360 337 1305 28 .GG marvin fiberglass in 0.320marvin fiberglass in 0.320 nn 27.8427.84 7.717.71 23 0 633 175 23 0 633 175 11 WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 nn 4.354.35 0.820.82 568 556 2419 455 120 120 522 98 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 nn 27.8427.84 7.717.71 12 0 334 93 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ee 5.655.65 0.930.93 322 226 1278 209 0 0 0 0GG10A-m10A-m 0.3200.320 ee 27.8427.84 15.3015.30 42 0 1169 642 0 0 0 0 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ee 27.8427.84 21.8521.85 54 0 1499 1176 0 0 0 0WW15B-15sfc-815B-15sfc-8 0.0590.059 ee 3.953.95 0.110.11 453 453 1787 51 453 453 1787 51 WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ee 4.354.35 0.820.82 408 327 1424 268 0 0 0 0GGmarvin fiberglass in 0.320marvin fiberglass in 0.320 ee 27.8427.84 21.8521.85 81 0 2248 1764 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 ss 5.655.65 0.930.93 528 390 2203 361 0 0 0 0 GG 10B-m10B-m 0.3200.320 ss 27.8427.84 9.079.07 39 0 1086 354 0 0 0 0GGmarvin fiberglass in 0.320marvin fiberglass in 0.320 ss 27.8427.84 12.9612.96 100 0 2770 1290 0 0 0 0 WW 15B-15sfc-815B-15sfc-8 0.0590.059 ss 3.853.85 0.080.08 300 277 1068 21 300 277 1068 21 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ss 27.8427.84 12.9612.96 23 0 633 295 23 0 633 295 WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ss 4.354.35 0.820.82 628 628 2732 513 180 180 783 147 WW 12F-0sw12F-0sw 0.0650.065 ww 5.655.65 0.930.93 498 315 1781 292 0 0 0 0GG1D-c2omd1D-c2omd 0.3200.320 ww 27.8427.84 21.8521.85 63 0 1754 1377 0 0 0 0GGmarvin fiberglass in 0.320marvin fiberglass in 0.320 ww 27.8427.84 21.8521.85 120 0 3336 2618 0 0 0 0 WW 15B-15sfc-815B-15sfc-8 0.0590.059 ww 5.145.14 0.000.00 1 -141 -724 0 1 -141 -724 0GG1D-c2omd1D-c2omd 0.3200.320 ww 27.8427.84 21.8521.85 42 0 1169 918 42 0 1169 918 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ww 27.8427.84 21.8521.85 100 0 2770 2174 100 0 2770 2174WWIECC2012 frame zone 0.050IECC2012 frame zone 0.050 ww 4.354.35 0.820.82 860 730 3174 597 452 452 1966 370 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ww 27.8427.84 21.8521.85 130 0 3626 2846 0 0 0 0 PP IECC2012 frame zone 0.050IECC2012 frame zone 0.050 --4.354.35 0.400.40 528 507 2205 202 0 0 0 0 DD 11N011N0 0.3500.350 nn 30.4530.45 8.918.91 21 21 639 187 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.741.74 0.980.98 1950 1950 3393 1909 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --1.481.48 0.220.22 431 431 637 94 0 0 0 0FF22D-10tpm22D-10tpm 0.3430.343 --29.8429.84 0.000.00 1519 187 5565 0 1519 187 5565 0 Job #: Performed for: Perron Residence Lakeville, mn Tony Ledo Phone: 763-229-4252 Tonyledo2012@gmail.com Scale: 1 : 140 Page 1 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Jun-22 14:58:50 ...der heating\perron Residence.rup N lower lower level 11'-6" 18'-0" 9'-6" 6'-6" 18'-0" 16'-0" 14'-0" 12'-0" 4'-0"30'-0" 16'-0" 8'-0" 4'-0" 22'-0" 1593 cfm 154 cfm 154 cfm 154 cfm Job #: Performed for: Perron Residence Lakeville, mn Tony Ledo Phone: 763-229-4252 Tonyledo2012@gmail.com Scale: 1 : 140 Page 2 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Jun-22 14:58:50 ...der heating\perron Residence.rup N main level main floor garage 158 cfm 158 cfm 158 cfm 158 cfm Job #: Performed for: Perron Residence Lakeville, mn Tony Ledo Phone: 763-229-4252 Tonyledo2012@gmail.com Scale: 1 : 140 Page 3 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Jun-22 14:58:50 ...der heating\perron Residence.rup N second second 8'-0" 2'-0"13'-0"6'-6" 13'-0" 6'-0" 29'-0" 134 cfm 134 cfm 134 cfm 134 cfm 07/17/18 X KH