Loading...
HomeMy WebLinkAboutitem 05City of Lakeville Planning Department Memorandum To: Planning Commission From: Frank Dempsey, AICP Associate Planner Date: November 30, 2018 Subject: Packet Material for the December 6, 2018 Planning Commission Meeting Agenda Item: Newman Conditional Use Permit Application Action Deadline: January 4, 2018 INTRODUCTION Scott and Debra Newman have applied for a conditional use permit to allow a combined accessory building square footage greater than 1,100 square feet and more than one detached accessory building on a lot in the RS-3, Single Family Residential District and Shoreland Overlay District. The property is located at 10055 - 205th Street on the south shore of Lake Marion. The project includes the removal of the existing home constructed in 1890, removal of an old detached garage and the construction of a new home and new detached accessory building (garage). An existing 94 square foot, six-foot tall garden shed is proposed to remain. The house and detached garage were recently demolished after issuance of a demolition permit by the City. The following exhibits are attached for your review: Exhibit A – Location/Zoning Map Exhibit B – Aerial Photo Map Exhibit C – Certificate of Survey Exhibit D – Building Plans (3 Pages) Exhibit E – List of approved conditional use permits for accessory buildings – 1981-2018 2 PLANNING ANALYSIS Existing Conditions. The subject property is 63,789 square feet (1.46 acres) in area. The property was platted in 1972 as one of 11 single family home lots along the south shore of Lake Marion known as Weichselbaums First Addition. The house constructed in 1890 remained on Lot 1. A number of additions were constructed on the home over the years. The entire area of the plat was previously operated as a vacation resort until the 1970’s. The property is served with city sewer and water. Adjacent Land Uses. The subject property is zoned RS-3, Single Family Residential District and Shoreland Overlay District. Adjacent land uses and zoning are as follows: North – Lake Marion East – Single Family Home (RS-3) South – 205th Street and Single Family Homes (RS-3) West – Single Family Home (RS-3) Setbacks. The minimum setbacks for the subject property are as follows: Front (south): 30 feet Lake (north): 75 feet from the Ordinary High Water Level (OHWL) Sides: 10 feet The new single family home will be set back 130 feet from the front property line, 225 feet from the OHWL and more than 20 feet to each side property line. The accessory buildings also meet setback requirements. Total Accessory Building Area. The applicant proposes to replace the previous detached garage with a new 528 square foot accessory building. The existing 94 square foot garden shed would remain. The total proposed area of accessory building space, including the attached garage, would be 1,422 square feet. The Zoning Ordinance allows 1,100 square feet of total accessory building area in the RS-3 District. Driveway. The existing driveway is paved with bituminous and will remain so following construction. Any part of the driveway disturbed by the new construction shall be paved prior to issuance of a Certificate of Occupancy for the new house. Building Height. A maximum allowable height for a detached accessory building in the RS-3 District is 15 feet. The proposed new detached accessory building will be 15 feet in height as defined by the Zoning Ordinance. The garden shed is approximately six feet in height. Existing Non-Conforming Conditions. There are no known non-conforming conditions on the property based on the survey submitted with the conditional use permit application. 3 CONDITIONAL USE PERMIT ANALYSIS The Zoning Ordinance allows the accessory building area requirement to be exceeded by conditional use permit subject to the following criteria as listed in Section 11-18-5 of the Zoning Ordinance: A. There is a demonstrated need and potential for continued use of the structure for the purpose stated. The new house will be constructed with an attached two car garage and will include a 172 square foot workshop area and will total 800 square feet. The Zoning Ordinance allows the attached accessory building space to be up to 1,250 square feet in area. The larger of the two detached accessory buildings will be used as a 528 square foot two-car garage with space for storage of personal and recreational/lake equipment. The total accessory building area is proposed to be 1,422 square feet. The use of the accessory buildings will be accessory to the principal use, a single-family home. B. No accessory building or private garage shall be utilized for all or a portion of a home occupation, for commercial activities or for commercial storage. This will be a stipulation of the conditional use permit. C. The accessory building has an evident reuse or function related to a single-family residential environment in urban service areas or hobby farm environment in nonurban service areas of the city. The proposed accessory building space is compatible and functional with a single family home use. Attached Exhibit F is a list of accessory building conditional use permits approved since 1981. The total proposed accessory building area will be approximately 2.2% of the area of the property, which is lower than a typical single family lot. D. Detached accessory buildings shall be maintained in a manner that is compatible with the adjacent residential uses and does not present a hazard to public health, safety and general welfare. The proposed detached garage building will be designed to match the exterior of the new house. The existing garden shed is constructed of finished metal. Both buildings will be compatible with the new home and other single family homes in the area. E. The performance standards and criteria of section 11-4-7 of this title shall be considered and a determination made that the proposed activity is in compliance with such criteria. The provisions of section 11-4-7 of the Zoning Ordinance (Conditional Use Permits) have been considered and satisfactorily met. Please refer to the attached findings of fact. 4 RECOMMENDATION Planning Department staff recommends approval of the Newman conditional use permit to allow a total accessory building area exceeding 1,100 square feet and two detached accessory buildings in the RS-3 District located at 10055 – 205th Street subject to the following stipulations: 1. The total accessory building area (combined attached and detached) on the property shall not exceed the dimensions shown on the plans approved by the City Council (approximately 1,422 square feet). 2. The accessory buildings shall not be used for the operation of any commercial business or for the storage of commercial materials or equipment. 3. The new detached garage accessory building shall be constructed of exterior materials to match the house. 4. All driveway and parking areas shall be paved with bituminous, concrete or paver brick in compliance with Zoning Ordinance requirements. P/OS RS-3 RST-2 RS-3 RS-3 RS-3 RS-3 RS-3 P/OS RS-3 RS-3 RM-1 L a k e M a r i o n J USTICE PATHITALY AVEJASMINEPATHJACQUARD AVEUPPER 205TH ST W ICALEE PATHITERI AVEJAGUART E R J U NOTRLJADE CIRITERIAVE207TH ST W 206TH STW 208TH ST W ITALY AVEJAGUARAVE205TH STW 206THSTW JUNCO T RL 201ST ST W 2 0 4 T H S T WISLANDVIEW CIR205THCTW 1 0 0 5 5 2 0 5 T H S T R E E T W E S T Newman Conditional Use Permit Property Information November 1 5, 2018 0 450 900225 ft 0 130 26065 m 1:4,800 Disclaimer: Map and parcel data are believed to be accurate, but accuracy is not guaranteed. This is not a legal document and should not be substituted for a title search,appraisal, survey, or for zoning verification. 3'-9"6'-4"3'-3"PPRROOPPOOSSEEDD FFRROONNTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//44"" == 11''--00"" 11 11 12 7 12 7 STONE VENEER W/ LIMESTONE CAP 10' x 8' O.H DOOR - STYLE T.B.D 10' x 8' O.H DOOR - STYLE T.B.D 6" LP CORNER LP SIDING L.P B. & BATTEN @ 16" O.C. 24" x 24" STONE VENEER BASE w/ LIMESTONE CAP 16" x 16" L.P. WRAPPED OVER 6" x 6" TRTD POST 8" L.P. FRIEZE BRD. 8" x 8" CEDAR GABLE BRACKET DEC. CEDAR BRACKET 4" CONC. SLAB 20" x 20" L.P. COLUMN ON 24" x 24" STONE VENEER BASE w/ LIMESTONE CAP L.P. BOARD & BATTENS @ 16" O.C. 8" L.P. FRIEZE BRD. 8" x 8" CEDAR GABLE BRACKET STONE VENEER W/ LIMESTONE CAP ALUM. SOFFIT & FASCIA 1x4 OVER 1x12 L.P. TRIM 30" O.H. TYP. L.P. BOARD & BATTENS @ 16" O.C. 6" LP CORNER 12 7 PPRROOPPOOSSEEDD LLEEFFTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//88"" == 11''--00"" 22 11 STONE VENEER w/ LIMESTONE CAP B. & BATTEN 12 7 12 7 STONE VENNER w/ LIMESTONE CAP 24" x 24" STONE BASE 16" x 16" CEDAR COLUMN PPRROOPPOOSSEEDD RREEAARR EELLEEVVAATTIIOONN SSCCAALLEE:: 11//44"" == 11''--00"" 33 11 LP SIDING L.P. BOARD & BATTENS @ 16" O.C. 1x4 OVER 1x12 L.P. TRIM 8" LP FRIEZE 8"x8" CEDAR BRACKET 6" L.P. CORNER TRIM 6" L.P. WDW TRIM 8" L.P. FRIEZE BRD. ALUM. SOFFIT & FASCIA L.P. BOARD & BATTEN BATTENS @ 16" O.C. ARCHITECTURAL ASPHALT SHINGLES L.P. BOARD & BATTENS @ 16" O.C. 12 7 STONE VENEER W/ LIMESTONE CAP PPRROOPPOOSSEEDD RRIIGGHHTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//88"" == 11''--00"" 44 11 12" X 12" BEAM 24" x 24" MFG STONE BASE 16" x 16" LP WRAPPED OVER 6" x 6" TRTD POST LP SIDING 6" LP CORNER 4" CONC. SLAB ARCHITECTURAL ASPHALT SHINGLES ALUM. SOFFIT & FASCIA 1x4 OVER 1x12 L.P. TRIM HEADER SPANS:HEADER SPANS: UP TO 4'-11" = 1 TRIMMER 5'-0" AND LARGER = 2 TRIMMERS ** UNLESS NOTED OTHERWISE ** 2'-6" 2'-6"2'-6"1'-6"2'-6"1'-6"2'-6"2'-6"1'-6"2'-3" 2'-6" 2'-3"2'-6"1'-6"2'-6"2'-6"3'-0"1'-6"NOTE: ALL GIRDERS & BEAMS RELATIVE TO THE ROOF STRUCTURE ARE TO BE ENG. & DESIGNED BY THE TRUSS MNF. REFER TO THE SPEC/LAYOUT SHEETS PROVIDED BY THE TRUSS MNF. PPRROOPPOOSSEEDD RROOOOFF PPLLAANN SSCCAALLEE:: 33//1166"" == 11''--00"" 55 11 77::1122 77::1122 77::1122 77::112277::112277::112277::1122 77::1122 77::1122 77::112277::1122 77::1122 77::112277::112277::112277::1122 77::1122 77::1122 77::112277::1122 77::1122 77::1122 PERMITPLANSHEET NUMBER© GONYEA TRANSFORMATIONS 2018REVISION SETLICENSE #BC672669CONCEPTS AND PLANS ARE PROPERTY OF GONYEA TRANSFORMATIONS(REMODELING SPECIALISTS LLC dba GONYEA TRANSFORMATIONS). SOLE USE BYGONYEA TRANSFORMATIONS FOR THE PURPOSE OF DESIGNING, PRESENTING,COSTING AND BUILDING WITH CLIENTS UNDER CONTRACT, ONLY. ANY USE BYPARTIES OTHER THAN GONYEA TRANSFORMATIONS FOR THE ABOVE WILL RESULTIN LEGAL ACTION.1000 Boone Ave. N. Suite 400 - Golden Valley, MN 55422 - Main 763.432.4510 - Fax 763.432.4501Gonyea Transformations10-18-18DEMO OF EXIST'GRE-BUILD NEWSTRUCTURENEWMAN RESIDENCE10055 205TH STREET WLAKEVILLE, MN 5504417-20-188-28-189-10-189-14-1810-9-1810-11-1810-18-18 REF.REF.26683080 PKT.30803380 PCKTICA2955 R.O. = 29" x 56 1/8" ICA2955 R.O. = 29" x 56 1/8"2680 PKT.ICAP2919R.O. 29" x 20 1/8"ICAP2919R.O. 29" x 20 1/8"ICAP2919R.O. 29" x 20 1/8"ICA2971 w/ICA2923 ABOVER.O. = 29" x 95 1/4"10'-0" HEAD HGT.ICA2971 w/ICA2923 ABOVER.O. = 29" x 95 1/4"10'-0" HEAD HGT.6080ICA2963 R.O. = 29" x 64 1/8" ICAP4963 R.O. = 49" x 64 1/8" ICA2963 R.O. = 29" x 64 1/8"3080ICA3735-2W R.O. 73" x 36 1/8"3080 PKT3080 PKT.3080 STEEL3080 PCKT4080 ICA3771R.O. = 37" x 72 1/8"ICA3771R.O. = 37" x 72 1/8"ICA3771R.O. = 37" x 72 1/8"ICA3371-2WR.O. 65" x 72 1/8"ICA2927R.O. = 29" x 28 1/8"ICAP5735R.O. 57" x 36 1/8"ICA3359R.O. = 33" x 60 1/8"ICA3359R.O. = 33" x 60 1/8"2 4 8 0 ICN3771 R.O. = 37" x 72 1/8" ICN5727 R.O. 57" x 28 1/8" ICN3771 R.O. = 37" x 72 1/8"30803080 TRAN. ABV 3080 PKT. ICA3735 R.O. 37" x 36 1/8" ICA3771 R.O. = 37" x 72 1/8" ICA3771 R.O. = 37" x 72 1/8" ICA3771 R.O. = 37" x 72 1/8" 3080 C.O. 3080 PKT 308010' x 8' O.H. DOOR 2-11 7/8" HDR. 10' x 8' O.H. DOOR 2-11 7/8" HDR.ICA2971 w/ICA2923 ABOVER.O. 29" x 95 1/4"10'-0" HEAD HGT.ICA2971 w/ICA2923 ABOVER.O. 29" x 95 1/4"10'-0" HEAD HGT.ICA2955 w/ICA2923 ABOVER.O. 29" x 79 1/4"10'-0" HEAD HGT.ICA2947R.O. 29" x 48 1/8"3080HEADER SPANS:HEADER SPANS: UP TO 4'-11" = 1 TRIMMER 5'-0" AND LARGER = 2 TRIMMERS ** UNLESS NOTED OTHERWISE **2'-6"17'-0"18'-6"22'-0"21'-6"3'-0" 7'-6"5'-0"4'-2"10'-1"7'-6"19'-9"6'-10"18'-2"11'-3"12'-2"12'-10"8'-0"12'-0"10'-0"27'-0"1'-0"40'-3"24'-9"6'-0"3'-0"75'-0"82'-0"11'-0"5'-9"10'-7"17'-3"2'-8"1'-4"8"2'-0"3'-0"30'-10"7'-4"25'-4"4'-6"4'-3"2'-9" 1'-4"8"10'-0"1'-8"8'-10"1'-8"1'-0"7'-0"1'-8"25'-11"5'-9"6'-9"25'-1"9'-5"2'-10"3'-6"2'-9"3'-7"16'-8"9'-0"68'-6"4'-0"4'-0"11'-0"10'-0"22'-1"9'-6"11'-6"26'-9" 1'-6"17'-7"10'-9"3'-11"8'-0"7'-7"5'-4"6'-6"5'-7"14'-10"15'-2"16'-8"6'-6"12'-7"2'-3"5'-3"8'-0"9'-0" 8'-6"8'-6"8'-10"3'-8"3'-8"2'-4"5'-0"4'-0"4'-0"4'-0"5'-0"4'-0"6'-3"6'-3"5'-0"4'-0"10'-0"10'-5"5'-10"10'-0"3'-6"10'-0"3'-6"3'-6"4'-3"82'-0" 5'-5"4'-7"6'-0"6'-0"2'-10"5'-2"3'-1"3'-6"3'-6"2'-9"4'-7"3'-0"4'-7"8'-8"4'-0"4'-0"8'-8"4'-0"3'-4"2'-7"8'-6"6'-0"11'-0"2'-9"7'-10"11'-4"7'-10" 1'-4"8"1'-4"8"4'-6"20'-0"2'-0" 6"3'-8"2'-10"4'-6"SSHHOOPP -- 117722 SSQQ FFTT OOFFFFIICCEE PPAANNTTRRYY GGAARRAAGGEE -- 662288 SSQQ FFTT SSIIDDEE PPOORRCCHH FFOOYYEERR LLIIBBRRAARRYY // HHAALLLL CURBLESS 18"t TILE BENCH MMAASSTTEERR BBAATTHH LLAAUUNNDDRRYY SSEECCUURREE RROOOOMM SSTTUUDDIIOO // LLIIBBRRAARRYY MUSIC CENTERHHAALLLL PPWWDDRR.. MMAASSTTEERR CCLLSSTT GGRREEAATT RROOOOMM KKIITTCCHHEENN OPEN BELOW FULL HGT. HANGING DDOOGG AARREEAA MMAASSTTEERR BBEEDDRROOOOMM CCOOVV.. PPOORRCCHHT.V. ABOVEBENCH w/ SHELF AND HOOKSDROPZONEMMUUDD.. // HHAALLLL T.V. ABOVE VAULT CLG FLAT 15' CLG33,,668855 SSQQ FFTT PPRROOPPOOSSEEDD MMAAIINN FFLLOOOORR PPLLAANN SSCCAALLEE:: 11//44"" == 11''--00"" 11 33 5) 18"d PANTRY SHELVES DOG CRATE DOG CRATE PANTRY CAB. LINEN SHELVES GLASS PANEL NO STEP NO STEP NO STEPUTILITY SINK DOG WASH 10' CLG11' CLG48" COUNTER DEPTH REF/FZR DW 5:12 VAULT5:12 VAULT 5:12 VAULT 10'-1 1/8" CLG HGT. TILE FLR - DROP FLR 1-1/2" TO ACCOMODATE IN FLOOR HEAT NO STEP CONTROLS HAND HELD24"x42" NICHE 8' CLG @ SHWR 10' CLG HGT. CARPET 10'-1 1/8" CLG HGT. LVT FLOOR 10'-1 1/8" CLG HGT. CARPET 12'-8" @ PEAK VAULTED CLG ENG. WOOD FLOOR KNEE WALL 10'-1 1/8" CLG HGT. ENG. WOOD FLOOR 10'-1 1/8" CLG HGT. LVT FLOOR 10'-1 1/8" CLG HGT. ENG. WOOD FLOOR 13'-5 1/8" @ PEAK ENG. WOOD FLOOR 10'-1 1/8" CLG HGT. CARPET 5:12 VAULT5:12 VAULT 5:12 VAULT 19'-10" @ PEAK VAULTED CLG ENG. WOOD FLOOR VAULTED CLG ENG. WOOD FLOOR 12'-8" @ PEAK VAULTED CLG ENG. WOOD FLOOR 7:12 VAULT 7:12 VAULT 7:12 VAULT 10'-5 1/8" CLG HGHT CONC. FLR FINISH, TAPE, & PAINT 10'-1 1/8" CLG HGT. LVT FLOOR 10'-1 1/8" CLG HGT. LVT FLOOR 10'-5 1/8" CLG HGHT CONC. FLR FINISH,TAPE, & PAINT 19 5 19 5 16 5 16 5 15 5 15 5 17 5 17 515 5 15 5 24 5 24 5 20 5 20 5 21 5 21 510'-1 1/8" CLG HGT. LVT FLOOR 22 5 22 5 11 5 11 5 10 5 10 5 9 5 9 5 13 5 13 5 23 5 23 5 14 5 14 5 NOTES:NOTES: 1)ALL INTERIOR & EXTERIOR HEADERS TO BE 2-2x10 UNLESS NOTED OTHERWISE 2)STAIR TREAD CUT SHOWN @ 10" - 7 3/4" MAX RISE 3)ALL ANGLED WALLS AT 45° UNLESS NOTED OTHERWISE 4)ALL DIMENSIONS TO OUTSIDE OF SHEATHING 5)MAIN FLOOR WINDOWS AT 8'-0" HEAD HGT. (TRANSOMS ABOVE) 6)GARAGE WALLS 2x6 7)ALL BATHROOM WALL TO BE INSULATED 8)4-1/2" RETURNS ON ALL DOORS UNLESS NOTED OTHERWISE 9)TRUSS MANUFACTURER TO VERIFY SIZE & SPACING OF TRUSSES 10)OSB ENTIRE EXTERIOR OF HOUSE 2 4 2 4 2 4 2 4 1 4 1 4 1 4 1 4 6"MULL3 4 3 4 3 4 3 4 18 5 18 5T.V. ABOVEBUILT-INBUILT-IN12" RAISED HEARTH7:12 VAULT DECOR. WOOD BEAMS DECOR. WOOD BEAMS DECOR. WOOD BEAMS DECOR. WOOD BEAMS DECOR. WOOD BEAMS FALCON DISPLAY ALUM. SOFFIT CLG CONC. FLR ALUM. SOFFIT CLG CONC. FLR ALUM. SOFFIT CLG CONC. FLR CCOOVV.. PPAATTIIOO DECOR. WOOD BEAMSDECOR. WOOD BEAMSDECOR. WOOD BEAMSDECOR. WOOD BEAMS OWNER'S EXIST'G TABLE TOP 22 222 - 2x102 - 2x102 - 2x102 - 2x102 - 2x10 2 - 2x10 2 - 9 1/2" LVL2 - 2x102 - 2x102 - 2x102 - 9 1/2" LVL 22 222 - 2x1022 22 2 - 2x10 2 - 14" LVL2 - 14" LVL22 222 - 9 1/2" LVL 2 - 2x1022 22 22 22 2 - 11 7/8" LVL 2 - 11 7/8" LVL 2 - 2x102 - 2x102 - 2x102 - 2x102 - 2x102 - 2x102 - 2x102 - 2x102 - 2x1022 22 EW P NOTES:EWP NOTES: TRUSS & TALL WALL LAYOUTS PROVIDED AT TIME OF ORDER 2 - 2x1022 33 22 223322332 - 2x10 2 - 2x102 - 2x10 12 5 12 5 TRENCH DRAIN66" x 36" FREE STD'G TUBCPT. @ STAIRS 2 - 2x10 2 - 2x10 CHASE DECO. BEAM 2 - 2x102 - 2x10ICN5727 ABOVE R.O. = 57" x 28 1/8" SET BOTTOM AT 108" 3-2x63-2x6 ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP9036 R.O. = 91" x 37" SET BOTTOM @ 9'-0" ICAP4260 R.O. = 43" x 61" SET BOTTOM @ 9'-0" ICAP4218 R.O. = 43" x 19" SET BOTTOM @ 9'-0" SEE TALL WALL DESIGN ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP4284 R.O. = 43" x 85" 8'-0" HEAD HGT. ICAP4218 R.O. = 43" x 19" SET BOTTOM @ 9'-0" ICAP4260 R.O. = 43" x 61" SET BOTTOM @ 9'-0" ICAP9636 R.O. = 97" x 37" SET BOTTOM @ 9'-0" IPD8080 R.O. = 96 1/4" x 96 1/8" SEE TALL WALL DESIGN EEXXIISSTT''GG DDEETTAACCHHEEDD GGAARRAAGGEE SSQQUUAARREE FFOOOOTTAAGGEE:: 1177''--22 11//22"" xx 1177''--44 11//22"" == 229999 SSQQ FFTT 2x4 WALL FOR SOUND INSUL. 2 - 2x8 2 - 2x8 2 - 2x8 2X8 WALL CONSTRUCTION AT GABLE WALL 2X8 WALL CONSTRUCTION AT GABLE WALL8'-0"9'-0"10'-1 1/8"OOWWNNEERR''SS BBEEDDRROOOOMM GGAABBLLEE WWAALLLL SSCCAALLEE:: 11//44"" == 11''--00"" 33 33 ICN3771 ICN3771 ICN5771 ICN572711'-1 1/8"8'-0"9'-0"GGRREEAATT RROOOOMM // DDIINNIINNGG GGAABBLLEE WWAALLLL SSCCAALLEE:: 11//44"" == 11''--00"" 22 33 ICAP4284 ICAP4284 ICAP4284 ICAP4284 ICAP4284 ICAP4284IPD8080 ICAP4218 ICAP4218 ICAP9036 ICAP9636 ICAP4260ICAP4260 PERMITPLANSHEET NUMBER© GONYEA TRANSFORMATIONS 2018REVISION SETLICENSE #BC672669CONCEPTS AND PLANS ARE PROPERTY OF GONYEA TRANSFORMATIONS(REMODELING SPECIALISTS LLC dba GONYEA TRANSFORMATIONS). SOLE USE BYGONYEA TRANSFORMATIONS FOR THE PURPOSE OF DESIGNING, PRESENTING,COSTING AND BUILDING WITH CLIENTS UNDER CONTRACT, ONLY. ANY USE BYPARTIES OTHER THAN GONYEA TRANSFORMATIONS FOR THE ABOVE WILL RESULTIN LEGAL ACTION.1000 Boone Ave. N. Suite 400 - Golden Valley, MN 55422 - Main 763.432.4510 - Fax 763.432.4501Gonyea Transformations10-18-18DEMO OF EXIST'GRE-BUILD NEWSTRUCTURENEWMAN RESIDENCE10055 205TH STREET WLAKEVILLE, MN 5504437-20-188-28-189-10-189-14-1810-9-1810-11-1810-18-18 16' x 8' O.H. DOOR306822'-0"1'-4"8"11'-0"11'-0"24'-0" 5'-0"19'-0"8"1'-4"8"1'-4" DDEETTAACCHHEEDD GGAARRAAGGEE 3 7 3 7 5 7 5 7 4 7 4 7 6 7 6 7PPRROOPPOOSSEEDD DDEETTAACCHHEEDD GGAARRAAGGEE SSCCAALLEE:: 11//22"" == 11''--00"" 22 77 553355 SSQQ FFTT 10' PLATE HEIGHT CONC. FLOOR SLOPED TO O.H. DOORS 7 7 7 7 2 - 2x10 2 - 11 7/8" LVLPPRROOPPOOSSEEDD LLEEFFTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//44"" == 11''--00"" 55 77 PPRROOPPOOSSEEDD BBAACCKK EELLEEVVAATTIIOONN SSCCAALLEE:: 11//44"" == 11''--00"" 44 77 PPRROOPPOOSSEEDD RRIIGGHHTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//44"" == 11''--00"" 66 7722'-0"3'-0"16'-3"2'-9"3'-4 1/2"3'-3"17'-4 1/2" 24'-0" 8"1'-4"8"1'-4"8"1'-4"8"1'-4"PPRROOPPOOSSEEDD DDEETTAACCHHEEDD GGAARRAAGGEE SSCCAALLEE:: 11//22"" == 11''--00"" 11 77 UUNNEEXXCCAAVVAATTEEDD 6" x 4'-0" POURED CONC. FROST WALL 2" INTERIOR LEDGE 16" x 8" CONT. CONC. FOOTING REBAR PER CODE 5 7 5 7 4 7 4 7 6 7 6 7 7 7 7 7 1'-6"1'-6"2'-6"2'-6"77::112277::112277::1122DDEETTAACCHHEEDD GGAARRAAGGEE RROOOOFF PPLLAANN SSCCAALLEE:: 11//44"" == 11''--00"" 88 7710'-1 1/8"2'-6" ENGINEERED ROOF TRUSSES @ 24" O.C. BY MANUFACTURER ASPHALT SHINGLES 15# ROOF FELT 1/2" OSB SHEATHING w/ CLIPS INSTALL ICE & WATER WITHIN 4' OF EXTERIOR WALLS CONT. RIDGE VENT VENT 1/300 OF ATTIC 50% AT RIDGE 50% AT EAVE TYP. O.H. 6" x 4'-0" POUR. CONC. FROST WALL 2" INTERIOR LEDGE AT 3'-4" ON 16" x 8" CONT. CONC. FTGS. REBAR PER CODE SIDING PER ELEVATION 7/16" OSB SHEATHING 2x4 STUDS AT 16" O.C. ALUM. SOFFIT & FASCIA 4" POURED CONC. GARAGE SLAB SLOPED TO O.H. DOOR BBUUIILLDDIINNGG SSEECCTTIIOONN SSCCAALLEE:: 11//22"" == 11''--00"" 77 77 3'-0"PPRROOPPOOSSEEDD FFRROONNTT EELLEEVVAATTIIOONN SSCCAALLEE:: 11//22"" == 11''--00"" 33 77 24" x 24" STONE VENEER BASE w/ LIMESTONE CAP 16" L.P. WRAPPED COLUMN 1x4 OVER 1x12 L.P. TRIM 8" L.P. FRIEZE BRD. L.P. BOARD & BATTEN BATTENS @ 16" O.C. 27" O.H. TYP. ALUM. SOFFIT & FASCIA 6" L.P. TRIM PERMITPLANSHEET NUMBER© GONYEA TRANSFORMATIONS 2018REVISION SETLICENSE #BC672669CONCEPTS AND PLANS ARE PROPERTY OF GONYEA TRANSFORMATIONS(REMODELING SPECIALISTS LLC dba GONYEA TRANSFORMATIONS). SOLE USE BYGONYEA TRANSFORMATIONS FOR THE PURPOSE OF DESIGNING, PRESENTING,COSTING AND BUILDING WITH CLIENTS UNDER CONTRACT, ONLY. ANY USE BYPARTIES OTHER THAN GONYEA TRANSFORMATIONS FOR THE ABOVE WILL RESULTIN LEGAL ACTION.1000 Boone Ave. N. Suite 400 - Golden Valley, MN 55422 - Main 763.432.4510 - Fax 763.432.4501Gonyea Transformations10-18-18DEMO OF EXIST'GRE-BUILD NEWSTRUCTURENEWMAN RESIDENCE10055 205TH STREET WLAKEVILLE, MN 5504487-20-188-28-189-10-189-14-1810-9-1810-11-1810-18-181 ACCESSORY BUILDING CONDITIONAL USE PERMITS Applicant Year Size (sf) Zoning Inside MUSA Parcel Size Newman 2018 1,422 RS-3 Yes 1.46 acres Poehling 2018 2,904 RS-2 Yes 2.74 acres Berres 2017 4,240 RS-3 Yes 10.00 acres Lynch 2016 1,617 RS-2 Yes 1.04 acres Durst 2016 1,656 RS-3 Yes 0.73 acres Boecker 2014 +2% Lot Area RA No 1.41 acres Radke 2013 22 feet tall RS-3/Shoreland Yes 0.38 acres Helman 2013 1,614 RS-3 Yes 1.0 acre Lau 2013 2,927 RA No 2.0 acres Sarff 2012 882 RST-2 Yes 0.38 acres Johnson 2010 16,760 RA No 9.6 acres Hellevik 2010 5 Bldgs RA No 10 acres Miler 2008 Exc. 15 ft RS-1 Yes 1.42 acres Goss 2008 4,032 RA No 30 acres Piekauski 2006 1,344 RS-3 Yes 1.60 acres Meyer 2006 1,572 RS-3 Yes 66 acres Rimnac 2005 2,096 RS-2 Yes 7.3 acres Spangler 2005 869 RS-2 Yes 2.3 acres Weinel 2004 1,480 RS-3 Yes 0.69 acres Hanson 2002 576 RS-3 Yes 1.5 acres Drogmuller 2002 2,184 RM-1 No 10 acres Steinman 2002 624 RM-1 Yes 1.4 acres Zeien 2001 1,102 RS-3 Yes 1.5 acres Emond 2001 864 RS-CBD Yes 0.25 acres Riehm 2000 1,310 RM-1 Yes 1.96 acres Graham 2000 1,078 RS-CBD Yes 0.57 acres Jensen 2000 1,470 RS-3 Yes 0.52 acres Laun 2000 952 RS-CBD Yes 0.50 acres Hendrickson 2000 4,452 R-2 Yes 15 acres Pietsch 1999 2,400 R-1 No 22 acres Smith 1999 896 R-3 Yes 0.35 acres Edmonson 1998 864 R-2 Yes 3.0 acres Krebs 1998 2,400 R-1 No 9.1 acres Forland 1998 1,462 R-1 No 5.0 acres Stuke 1998 2,520 R-1 No 20 acres Miller 1996 2,240 R-2 Yes 3.7 acres Menke 1996 1,620 R-2 Yes 15 acres Teal 1996 2,160 R-2 Yes 10 acres Curren 1995 960 R-2 Yes 3.0 acres Cronen 1995 2,396 R-1 No 10 acres Koble 1994 2,400 R-2 Yes 10 acres Goetze 1993 1,232 R-2 Yes 4.3 acres Fenner 1993 936 R-2 Yes 9.5 acres Oster 1992 2,400 R-2 Yes 10 acres Clifford 1990 288 R-1 No 20 acres Moe 1990 1,600 R-2 Yes 2.0 acres Olson 1989 1,728 R-2 Yes 9.4 acres Storlie 1989 1,196 R-1 Yes 3.0 acres Moss 1985 2,000 R-1 Yes - Tangen 1984 1,800 R-2 Yes - Grossman 1983 672 RA Yes - Johnson 1983 3,402 R-1 Yes - Radunz 1983 5,000 R-2 Yes - LaFavor 1983 1,600 R-2 Yes - Harris 1982 900 R-2 Yes - Campbell 1982 400 R-2 Yes - Kalmes 1982 720 R-2 No - Zak 1981 1,632 I-1 No 1 CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA NEWMAN CONDITIONAL USE PERMIT FINDINGS OF FACT AND RECOMMENDATION On December 6, 2018 the Lakeville Planning Commission met at it’s regularly scheduled meeting to consider the request of Scott and Debra Newman for a conditional use permit to allow a combined accessory building area greater than 1,100 square feet and more than one detached accessory building for a single family home in the RS-3 Single Family Residential District and Shoreland Overlay District on property located at 10055 - 205th Street. The Planning Commission conducted a public hearing on the proposed conditional use permit preceded by published and mailed notice. The applicant was present and the Planning Commission heard testimony from all interested persons wishing to speak. FINDINGS OF FACT 1. The property is located in Planning District No. 4 of the 2008 Comprehensive Plan, which guides the property for low density residential uses. 2. The property is zoned RS-3, Single Family Residential District. 3. The legal description of the property is: Lot 1, Block 1, Weichselbaum First Addition 4. Section 11-4-3E of the City of Lakeville Zoning Ordinance provides that a conditional use permit may not be issued unless certain criteria are satisfied. The criteria and our findings regarding them are: a. The proposed action has been considered in relation to the specific policies and provisions of and has been found to be consistent with the official City Comprehensive Plan. Finding: The proposed single family use of the property is consistent with the 2030 Land Use Plan and District 4 recommendations of the Comprehensive Plan. The property is 1.46 acres in area. The proposed attached and detached accessory buildings are consistent with single family lots of this size. b. The proposed use is or will be compatible with present and future land uses of the area. Finding: The attached and detached accessory buildings will be compatible with present and future land uses in the area. c. The proposed use conforms with all performance standards contained in the Zoning Ordinance. 2 Finding: Provided compliance with the conditional use permit, the two detached accessory buildings and the use of that space will conform with all performance standards contained in the Zoning Ordinance and the City Code. d. The proposed use can be accommodated with existing public services and will not overburden the City’s service capacity. Finding: The subject property lies within in the current MUSA. The property is served with City sanitary sewer and water. The accessory building square footage will have no impact on the City’s service capacity. e. Traffic generation by the proposed use is within capabilities of streets serving the property. Finding: The accessory buildings will not overburden the streets serving the property. 5. The planning report dated November 30, 2018 prepared by Associate Planner Frank Dempsey is incorporated herein. RECOMMENDATION The Planning Commission recommends that the City Council approve the conditional use permit. DATED: December 6, 2018 LAKEVILLE PLANNING COMMISSION BY: ______________________________ Pat Kaluza, Chair