Loading...
HomeMy WebLinkAboutItem 07 Date: Item No. PUBLIC HEARING ON-SALE AND SUNDAY LIQUOR LICENSE LAKEVILLE BURGER LLC Proposed Action Staff recommends adoption of the following motion: Move to grant an on-sale and Sunday liquor license and outdoor patio to Lakeville Burger LLC d.b.a. B-52 Burgers & Brew, 20751 Holyoke Avenue. Overview Lakeville Burger LLC has applied for an on-sale and Sunday liquor license at the former Erickson Drug building in downtown Lakeville. B-52 Burgers & Brew will consist of a full-service restaurant with a bar and outdoor patio. The patio application has been reviewed by the planning, building inspections and police departments, and all recommend approval. The police department conducted a background investigation on the partners Brandon Bramscher, Ryan Wentz, Mark Reese and Michael McMahon, and found no reason to deny the license requested. Ryan Wentz will be present at Monday night’s public hearing. Primary Issues to Consider • Does the applicant meet all requirements for the licenses requested? • The applicant meets all City and State requirements for an on-sale and Sunday liquor license. Supporting Information • Police Department investigative summary • Patio application and site plan Financial Impact: $ Budgeted: Y☐ N☐ Source: Related Documents: (CIP, ERP, etc.): Envision Lakeville Community Values: Good Value for Public Services Report Completed by: Char Friedges, City Clerk December 3, 2018 B-52 Burgers and Brew 20751 Holyoke Avenue, Lakeville, MN 55044 Investigative Summary for Lakeville City Council Lt. Jim Puncochar Applicants: Lakeville Burger DBA B-52 Burgers and Brew Michael McMahon Mark Reese Brandon Bramscher Ryan Wentz License Applied For: • Liquor • Sunday Liquor Date: 11-14-18 Background Investigation Process On November 13, 2018, I was assigned to the liquor license background investigation of the B-52 Burgers and Brew. The above person(s) were listed on the license application and completed the required personal information application. The following automated databases were checked to conduct this background; DVS, MNCIS, in-house records, and criminal history files. Conclusion The background investigation is complete. Based on State Statute and Lakeville ordinance, the applicants meet the qualifications for a liquor and Sunday liquor license for B-52 Burgers and Brew. D06D06 D10D10 N 35'5'35'22' 4'-11 1/2" WALK-IN BEER COOLER WALK-IN FREEZER WALK-IN COOLER 10080 OHD GLASS10080 OHD GLASS10080 OHD GLASSLAY BLOCK ON EXISTING LEDGE HAND DRYER HAND DRYER RECESSED NICHE FOR MERCHANDISE 12" PLUMBING WALL ELECTRIC METER 1:12 RAMP OFFICE DRY STORAGE DISH ROOM RECEIVING PATIO 10080 OHD TEMPERED GLASS42" HIGH BLACK RAILING FLOOR RAISED 14" 48" HIGH WALL 48" HIGH WALL 96" HIGH WALL PREP AREA LIQUOR STORAGE 108" HIGH WALLS 30"x47"30"x47"SERVIVE DELIVERY ENTRANCE 1 STEP 2 RISERS 24"x36"21"x72"74"x48" BOOTH74"x48" BOOTH30"x47"74"x48" BOOTH30"x47"74"x48" BOOTH1616 1717 1818 1818 GATE 36" w/ PANIC HARDWARE SERVER STATION BAR AREA 24"x24" CEILING GRID 24"x48" FLUORESCEN T LIGHTS MECHANICAL 24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"MECHANICAL ROOM WATER SERVICE WATER SERVICE OFFICE REAR DELIVERY AREA ENTRANCE UTILITY BOXES 36" HIGH HANDRAIL12" HANDRAIL EXTENSION 36" HIGH HANDRAIL 12" HANDRAIL EXTENSION NOTES:1. SEPARATE SEWER AND WATER PERMIT REQUIRED.INSPECTIONS AND TESTING REQUIRED PRIOR TO BACKFILL.2. A COPY OF THE CITY APPROVED PLAN IS TO BEPROVIDED ON THE JOB SITE FOR THE INSPECTOR.3. MEP, SIGNS, & FIRE SUPPRESSION/ALARMS TO BEPROVIDED BY OTHERS.4. VAPOR BARRIER REQUIRED ON WARM SIDE OF ALLEXTERIOR WALLS AND CEILINGS PER IBC 1405. 5. SEALED ELECTRICAL BOXES REQUIRED PER CODE. 6. THE MEANS OF EGRESS, INCLUDING THE EXITDISCHARGE, SHALL BE ILLUMINATED AT ALL TIMESTHE BUILDING SPACE SERVED BY THE MEANS OFEGRESS IS OCCUPIED. PROVIDE EMERGENCY POWERFOR ILLUMINATION. (IBC 1006)7. NOTE: ALL GLAZING IN AN INDIVIDUAL FIXEDOR OPERABLE PANEL THAT MEETS ANY OFTHE FOLLOWING SHALL BE TEMPERED (IBC 240) (A) INDIVIDUAL PANE > 9 SQ.FT. (B) BOTTOM EDGE < 18" ABV. FLOOR (C)TOP EDGE > 36" ABV. FLOOR (D)WALKING SURFACE WITH 36" PROVIDE MIN. OF 12" CLEARANCE SPACE ON PUSH SIDE OF DOORS 8. AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALLBE PROVIDED THROUGHOUT THE BUILDING AS PERIBC 903.2.1.2. PROVIDE MIN. OF 18" CLEARANCE ON PULL SIDE OF DOORS NOTE: WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. (IBC 1210.2.2) ACCESSIBLE TURNING SPACE 42" GRAB BAR SELF-CLOSING DOOR60"x36" AMBULATORY ACCESSIBLE STALL 42" GRAB BAR ALL DOORS WITH A LOCKOR LATCH SHALL BE PRO- VIDED WITH PANIC HARD- WARE AS PER IBC 1008.1.10 36" GATE w/ PANIC HARDWARE 42" HIGH RAILING METAL RAIL POSTS EVERY 60" - 72"42''14''EXTERIOR INTERIOR 24"x42" FOOTING EXISTING ASPHALT METAL RAIL POSTS EVERY 60" - 72" D09D09 D11D11 N 9'-5"11"1'-1 3/8"14'-5 1/8"5'-10" 60" MIN.44'WALK-IN BEER COOLER WALK-IN FREEZER WALK-IN COOLER 10080 OHD GLASS10080 OHD GLASS10080 OHD GLASSLAY BLOCK ON EXISTING LEDGE HAND DRYER HAND DRYER RECESSED NICHE FOR MERCHANDISE 12" PLUMBING WALL ELECTRIC METER 1:12 RAMP OFFICE DRY STORAGE DISH ROOM RECEIVING PATIO10080 OHD TEMPERED GLASS42" HIGH BLACK RAILING FLOOR RAISED 14" 48" HIGH WALL 48" HIGH WALL 96" HIGH WALL PREP AREA LIQUOR STORAGE 108" HIGH WALLS 33 30"x47"30"x47"SERVIVE DELIVERY ENTRANCE 1 STEP 2 RISERS 24"x36"21"x72"74"x48" BOOTH74"x48" BOOTH30"x47"74"x48" BOOTH30"x47"74"x48" BOOTHGATE 36" w/ PANIC HARDWARE SERVER STATION BAR AREA 24"x24" CEILING GRID 24"x48" FLUORESCEN T LIGHTS MECHANICAL 24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"24" x 48"MECHANICAL ROOM WATER SERVICE WATER SERVICE OFFICE REAR DELIVERY AREA ENTRANCE UTILITY BOXES 36" HIGH HANDRAIL12" HANDRAIL EXTENSION 36" HIGH HANDRAIL 12" HANDRAIL EXTENSION NOTES:1. SEPARATE SEWER AND WATER PERMIT REQUIRED.INSPECTIONS AND TESTING REQUIRED PRIOR TO BACKFILL.2. A COPY OF THE CITY APPROVED PLAN IS TO BEPROVIDED ON THE JOB SITE FOR THE INSPECTOR.3. MEP, SIGNS, & FIRE SUPPRESSION/ALARMS TO BEPROVIDED BY OTHERS. 4. VAPOR BARRIER REQUIRED ON WARM SIDE OF ALL EXTERIOR WALLS AND CEILINGS PER IBC 1405. 5. SEALED ELECTRICAL BOXES REQUIRED PER CODE. 6. THE MEANS OF EGRESS, INCLUDING THE EXITDISCHARGE, SHALL BE ILLUMINATED AT ALL TIMESTHE BUILDING SPACE SERVED BY THE MEANS OFEGRESS IS OCCUPIED. PROVIDE EMERGENCY POWERFOR ILLUMINATION. (IBC 1006)7. NOTE: ALL GLAZING IN AN INDIVIDUAL FIXEDOR OPERABLE PANEL THAT MEETS ANY OFTHE FOLLOWING SHALL BE TEMPERED (IBC 240) (A) INDIVIDUAL PANE > 9 SQ.FT. (B) BOTTOM EDGE < 18" ABV. FLOOR (C)TOP EDGE > 36" ABV. FLOOR (D)WALKING SURFACE WITH 36" PROVIDE MIN. OF 12" CLEARANCE SPACE ON PUSH SIDE OF DOORS 8. AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALLBE PROVIDED THROUGHOUT THE BUILDING AS PERIBC 903.2.1.2. PROVIDE MIN. OF 18" CLEARANCE ON PULL SIDE OF DOORS NOTE: WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. (IBC 1210.2.2) ACCESSIBLE TURNING SPACE 42" GRAB BAR SELF-CLOSING DOOR60"x36" AMBULATORY ACCESSIBLE STALL 42" GRAB BAR ALL DOORS WITH A LOCK OR LATCH SHALL BE PRO- VIDED WITH PANIC HARD- WARE AS PER IBC 1008.1.10 36" GATE w/ PANIC HARDWARE 42" HIGH RAILING METAL RAIL POSTS EVERY 60" - 72" A-7 SHEET: DATE: 11/29/2018INTERIOR BUILDOUT FOR B52 BURGERS & BREWS20751 HOLYOKE AVE., LAKECILLE, MN 55044REAR PATIO SCALE: 1/2" = 1'-0" CROSS SECTION SCALE: 1/4" = 1'-0" 1818 CROSS SECTION SCALE: 1/4" = 1'-0" CROSS SECTION SCALE: 1/4" = 1'-0" FRONT PATIO SCALE: 3/8" = 1'-0"