HomeMy WebLinkAboutSURVEY 8.5x14 FY-20'House,25'Garage ,' � ' ` �'` ' � • '! � ainta between bottom ot siding d
'oning-RS-4 ' 'M in 6" an sod.
��;� 1 �_.� ; \,� ., �� �- � �, x `:-� ' 'No structures in easements.
�� �
'�S�' -���flt6flOf,2�'Comer The curb box,drain tile cleanout,and catch !.
basn�if applicable)must be mspectetl and
RY-30� accepted before As-Built escrow monies wdi ;
�Y Buffer-30� be releasetl. All structures must be flush
RY Buffer-50� with the sotl. This will be scheduled with the;
lantlscape inspection.
EROSION CONTROL
MUST BE INSTALLED
Exist'^9 3EFORE EXCAVATION
929.0� House
fOb 972 9
924.0
923.0
2�.02 MW
S87°28�12"W R� 98.46 � '5 x920.�
�57g°p6 S
Vacant x e2o.o
30 , ,�h
'�= �22.12 �" x ezo.z
x e,a.�
i mr °�e �$ x931.2 �28.47 i.,� enchmork � �
� 's a enchmark x 941.31 919.6 919'��
%922.E X 921.2
�� - t0 x 933.1 x g31.8 x 929.4 x 9222
y� p '� N x 92E.a 45.52 �822.0� (920.3) 970.! Ol x 915.6
928.0 x 9so.o
i 'D�� �s ��, � 25.51 ( � eso.s v'
x 926.2 x 8224 I 2`�� ���� �Q v /
, 9Q�4_ 9��� oN 927. I�______� I %
oL-jb---------- I� ms.� �
�� ,x 927.1 921.E �� I � �915.4
�� �
� � 927.8 . 1 _ I r 1
o e� , � x pn.e e.n 31.67 ' x a2z.i � x ezzi 1� 1
�°g �e .4J �uxni o i � o. i x 920.1 y o 1� 1
� �QjX j d o �ro o i I =n �
r I v � � � -- pp I x 821.6 7
Q� � I I r�i p O> x YS�7A I � y 919.9 �
� � O.� � .n�-� C a �916.0
� ,��� szQ* e,�* � � ,;N�3 ezi.g � °c � POND 2
W 928.5 �92�.1 ./927.7 -� a O m'osz.s 2. 0 x a . � 14 � o E 1 NWL=915.36
i 11.83 0=_ x �,n K � c y 3 j 1 0 1 R H W L=9 1 7.6 8
� x az�.a '�a '� � � X nNj."� � � e � 100 1R HWL=919.49
� i ��. � x;o��.o � � �x oz,., x.zd.6� � �
Z W , K � �3 � o �, � ' � s.s
� �
, � i' 921.9 �( _�_'�_�I�� 18.� �
�i ln ^ v' ne�o> `" o% I ezi s -'t---- 54.0 - � �
� oi xp2e.i o 0 7 M 1
w p� I a� c� � o i - ° ►�,,Edge of water
N���, '9� i9�a, ---'25.5--g2ze ��z� 21.50x ao, I x vs�.a I O 1 03-11-20
0
Q ' I I .O �'927.5 . �2.0 I Z �
� N � x exe.3 � � 20.00 ao axze� i x szi.e x azo.a I �i9.e �
I �. � I 915.7
_--_____-__
10 F ssze ezza i a, �p �
o �
�--��+ 'o---------%J �
-------- •
sze.�- �o �
I g�j ��82 92E.3 g� O ' Y2I.2 x 821.8 � 919.7 919.5 *915.7
r> O 25.50 (929.5) 45.50 � �
� �21.72 �' I
�C 915.8
i a?� ,,�e,a?� Iv x av.a enchmark 9�9 x exas �'�919.8
� x ese.s �27.92 X 9I7.6 x ou x x ssi.a
enchmork
� � � � �" �
� �
� 30 ' � N89°20'09"E 125.00 �
ENGINEERING REVIEWED
�ate Q3123/2020 aoxborou�c h
Lot area � 8955 SF � Denotes Iron pipe
House orea = 1769 SF +� Denotes sxNce Lowest floor elevotion per grading plon :922.5
Poreh area � 123 SF � omotea telewston box
Sfdewalk area � 44 SF � oenotes electric box House elevations 1Pr000sed) / As-built
Drtveway area � 651 SF
Totol Impervious Area � 2587 $F ❑� Denotes telephone Dox Lowest Floor Elevation ;(923.2) �
Imperviou6 Coveraqe � 28.OS X 000.00 Denotes existing eievatim Top Of Foundation Elev. : 931.2
( 000.00 ) Denotes proposed elewtion � � �
� Denotee drainage flow direction Garoge Slob Elev. O Door ;(Q3�,8� �
� Dmotes epike
Construction Notes: �-'�
1. Install rock construction entrance. 0� 10� 20�
2. Install silt fence as needed for erosion control. �
3. Sidewalks shall drain away from house a minimum of 1.0'.
4. Contractor must verify driveway design.
5. Contractor must verify service devation prior to
construCtion.
6. Add or remove foundation ledge os required. Scale: 1'� = 20�
er.erol Notes: ��
Benchmark:
. Grading plan by KJ Walk last dated 6-30-19 was used to determine proposed We hereby certify to Brandl Anderson Homes Inc that this survey, Top Nut Hydront
levations shown herein. plan or report wos prepared by me or under my direct supervision, Lot 1 Block 2
. This survey does not purport to show improvements or encroachments, except as and that I om a duly licensed Land Surveyor under the lows of the Elevation = 930.13
hown, as surveyed by me or under my direct supervision. State of Minnesota, dated 03/09/20.�
. Proposed building dimensions shown are for horizontal locotion of structures on
he lot only. Contact builder prior to construction for approved construction plons. Signed: iq eer En ineering, P.A. R����
. No specific soils investigation hos been performed on this lot by the surveyor. I.)o3-ii-zosukehouse
he suitability of soils to support the specific house proposed is not the �
esponsibility of the surveyor. BY:
. This certificate does not purport to show easements other than those shown on
he recorded plat. e er . aw inson, ro essiono on urveyor
. Bearings shown ore based on an assumed dat�m. Minnesota License No. 42299 email-phawkinsonOpioneereng.com
PI�NEER Lot 14, Block 3,
��kERs uNu�AN.�= A��1'�$''P� KNOB HILL OF LAKEVILLE Certificate of Survey for:
�us��L,"� �.��R� according to the recorded plot thereof Brandl Anderson Homes Inc
2422Ente�priseDrive Pn.:e6si�c�i_ivia Dakota County, Minnesota
Mendota Heighw,MN 55120 Fax:(65 q 6R1-9488 221 River Ridge Circle South.Suile IOD
www.pioncv�reng.com Address: 17950 Eventide Woy, Lokeville, Mlnnesoto Bumsvilk,MN 55337
House Model: Eastridge Elevation: N/A pho,x:(952)89R-023o
�7��+� 1 1 91 3 501 1 FolderN:8379 DreHnby:CWM Buyer. Stovall
�Pioneer Engineering