Loading...
HomeMy WebLinkAboutLA167044 - 17851 Element Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: S e c u r e d o o r c l o s e d u n t i l d e c k i s c o n s t r u c t e d w i t h a s e p a r a t e p e r m i t . C o n c e p t A p p r o v a l O N L Y S u b j e c t t o F i e l d I n s p e c t i o n I n s p e c t o r D a t e 2 0 1 5 M N B l d g C o d e 0 2 / 2 1 / 2 0 1 9 d m a t h e w s U F E R G r o u n d - P r o v i d e 2 0 ' R e b a r i n f o o t i n g a n d s t u b u p n e a r e l e c t r i c a l s e r v i c e p a n e l . Tempe r i f g l a s s within 6 0 " o f f l o o r . T e m p e r i f g l a s s w i t h i n 6 0 " o f f l o o r a n d 2 4 " o f d o o r . - M i n . 1 5 " c l e a r a n c e t o a n y o b s t r u c t i o n f r o m c e n t e r o f W . C . , 2 4 " i n f r o n t ( t y p ) . R - 4 o n p i p e i n a t t i c 01: Upper Level Member Name Results Current Solution Comments Owner's Suite Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #2 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #3 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bed #4 WIC Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Stairway Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Owner's Bath Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 02: Main Level Member Name Results Current Solution Comments Kitchen Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Patio Door Passed 3 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Window Rear Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Office Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Drop Beam over Front Porch (H)Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Beam over Foyer (H)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Flush Beam over Foyer (V)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Foyer Entry Door Passed 3 Piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Flush Beam over Foyer/Dining Room (H)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Beam over Pantry Passed 2 Piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL 16' Garage Door Opening Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 8' Garage Door Opening Passed 2 Piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 Bath Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Garage Mudroom Service Door Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Side Windows (2)Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Mudroom Opening Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 03: Lower Level Member Name Results Current Solution Comments Bath Door Passed 2 Piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Beam over Hallway/Mech Room Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #5 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Family Room Patio Door Passed 2 Piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Family Room Window Passed 3 Piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL WIC Door Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 17851 Element Ave, Lakeville, MN.4te JOB SUMMARY REPORT Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 1 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None 2 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1156 @ 1 1/2"3825 (3.00")Passed (30%)--1.0 D + 1.0 S (All Spans) Shear (lbs)878 @ 1' 1/4"2872 Passed (31%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2314 @ 4' 3"3946 Passed (59%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.040 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.102 @ 4' 3"0.412 Passed (L/967)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Owner's Suite WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 7.0 1 - Uniform (PSF)0 to 8' 6"3'20.0 35.0 Snow - Main 2 - Uniform (PSF)0 to 8' 6"1'100.0 -Wall - Gable Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 2 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bedroom #2 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 3 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bedroom #3 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 4 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"345 591 936 None 2 - Trimmer - SPF 1.50"1.50"1.50"345 591 936 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)936 @ 0 1913 (1.50")Passed (49%)--1.0 D + 1.0 S (All Spans) Shear (lbs)191 @ 10 3/4"2872 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)527 @ 1' 1 1/2"3946 Passed (13%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.001 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bed #4 WIC WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"15'20.0 35.0 Snow - Main Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 5 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None 2 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1768 @ 0 1913 (1.50")Passed (92%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1023 @ 10 3/4"2872 Passed (36%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1879 @ 2' 1 1/2"3946 Passed (48%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.022 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Stairway WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 7.0 1 - Uniform (PSF)0 to 4' 3"15'20.0 35.0 Snow - Main Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 6 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None 2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans) Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Owner's Bath WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main 2 - Uniform (PSF)0 to 2' 3"1'100.0 -Wall - Gable Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 7 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None 2 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1143 @ 0 1913 (1.50")Passed (60%)--1.0 D + 1.0 L (All Spans) Shear (lbs)597 @ 10 3/4"2498 Passed (24%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1071 @ 1' 10 1/2"3431 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 10 1/2"0.125 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.010 @ 1' 10 1/2"0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Kitchen WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 9"N/A 7.0 1 - Uniform (PSF)0 to 3' 9"9' 6"15.0 40.0 Floor - Upper Level 2 - Uniform (PLF)0 to 3' 9"N/A 80.0 -Wall - Upper Level Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 8 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.09"1791 1040 1913 4744 None 2 - Trimmer - SPF 3.00"3.00"1.50"1022 1040 581 2643 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4006 @ 1 1/2"5738 (3.00")Passed (70%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)2837 @ 1' 1/4"4308 Passed (66%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)5231 @ 2'5919 Passed (88%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.045 @ 3' 1 1/16"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.081 @ 3' 1 1/16"0.313 Passed (L/921)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Dining Room Patio DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.6 1 - Uniform (PLF)0 to 6' 6"N/A 80.0 --Wall - Upper Level 2 - Uniform (PSF)0 to 2'15'20.0 -35.0 Snow - Main 3 - Uniform (PSF)0 to 6' 6"8'15.0 40.0 -Floor - Upper Level 4 - Point (lb)2'N/A 844 -1444 Linked from: Bedroom #2 Window, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 9 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"728 584/-67 787 2099/-67 None 2 - Trimmer - SPF 4.50"4.50"4.54"2513 1566 2799 6878 None 3 - Trimmer - SPF 4.50"4.50"3.26"1783 1566 1604 4953 None 4 - Trimmer - SPF 3.00"3.00"2.05"1107 626/-67 1384 3117/-67 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5786 @ 3' 9 3/4"5738 (4.50")Passed (101%)--1.0 D + 0.75 L + 0.75 S (Adj Spans) Shear (lbs)2430 @ 6' 8 3/4"2872 Passed (85%)1.15 1.0 D + 1.0 S (Alt Spans) Moment (Ft-lbs)-2244 @ 3' 9 3/4"3946 Passed (57%)1.15 1.0 D + 0.75 L + 0.75 S (Adj Spans) Live Load Defl. (in)0.008 @ 5' 9 3/4"0.129 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.012 @ 5' 10"0.194 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 8" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 8" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Great Room Window RearMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 7 1/2"N/A 7.0 1 - Uniform (PSF)0 to 11' 7 1/2"8' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 11' 7 1/2"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6"15'20.0 -35.0 Snow - Main 4 - Point (lb)6' 6"N/A 844 -1444 Linked from: Bedroom #3 Window, Support 1 5 - Point (lb)11' 7 1/2"N/A 844 -1444 Linked from: Bedroom #3 Window, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 10 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.97"1346 878 683 2907 None 2 - Trimmer - SPF 3.00"3.00"1.97"1346 878 683 2907 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2516 @ 1 1/2"3825 (3.00")Passed (66%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1304 @ 1' 1/4"2498 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2714 @ 3' 3"3431 Passed (79%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.037 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.074 @ 3' 3"0.313 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Office WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 1 - Uniform (PSF)0 to 6' 6"6' 9"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 6' 6"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 6"3'20.0 -35.0 Snow - Main 5 - Uniform (PSF)6' to 6' 6"3'20.0 -35.0 Snow - Main 6 - Uniform (PSF)0 to 6"1'100.0 --Wall - Gable 7 - Uniform (PSF)6' to 6' 6"1'100.0 --Wall - Gable 8 - Point (lb)6"N/A 459 -289 Bedroom# 4 Window Support 1 9 - Point (lb)6'N/A 459 -289 Bedroom# 4 Window Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 11 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"1.50"522 841 1363 Blocking 2 - Column - SPF 5.50"5.50"1.50"537 863 1400 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1400 @ 11' 8 1/4"7013 (5.50")Passed (20%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1084 @ 1' 2 3/4"2872 Passed (38%)1.15 1.0 D + 1.0 S (Alt Spans) Moment (Ft-lbs)3649 @ 6' 1/16"3946 Passed (92%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.189 @ 6' 1/8"0.378 Passed (L/722)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.306 @ 6' 1/8"0.568 Passed (L/446)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD Member Pitch: 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 7" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 12' 2" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Drop Beam over Front Porch (H)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 2"N/A 7.0 1 - Uniform (PSF)0 to 12' 2" (Front)4'20.0 35.0 Snow - Porch Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 12 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger •¹ See Connector grid below for additional information and/or requirements. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - LSL 5.50"5.50"1.50"1625 589 1909 4123 None 2 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1454 581 1633 3668 See note ¹ All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3148 @ 6' 2 1/2"4725 (1.50")Passed (67%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2118 @ 5' 2 5/8"9878 Passed (21%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)4594 @ 3' 9"18346 Passed (25%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.028 @ 3' 3 1/2"0.147 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.053 @ 3' 3 1/2"0.294 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 3" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer (H)MEMBER REPORT PASSED Connector: Simpson Strong-Tie Connectors Support Model Seat Length Top Nails Face Nails Member Nails Accessories 2 - Face Mount Hanger HHUS48 3.00"N/A 22-10d 8-10d None Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 2 1/2"N/A 13.0 1 - Uniform (PSF)0 to 6' 6" (Front)4' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 6' 6" (Front)N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6" (Front)1'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 1' 9" (Front)15'20.0 -35.0 Snow - Main 5 - Uniform (PSF)3' 9" to 6' 6" (Front)15'20.0 -35.0 Snow - Main 6 - Point (lb)1' 9" (Front)N/A 345 -591 Linked from: Bed #4 WIC Window, Support 1 7 - Point (lb)3' 9" (Front)N/A 345 -591 Linked from: Bed #4 WIC Window, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 13 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. •At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger •¹ See Connector grid below for additional information and/or requirements. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"3.72"4020 906 5422 10348 Blocking 2 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"824 558 860 2242 See note ¹ All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)9442 @ 1' 2 3/4"13956 (5.50")Passed (68%)--1.0 D + 1.0 S (All Spans) Shear (lbs)7899 @ 2' 5 3/8"9878 Passed (80%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)13418 @ 3' 1 3/4"18346 Passed (73%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.180 @ 5' 11 5/8"0.274 Passed (L/732)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.322 @ 6' 3/16"0.549 Passed (L/410)--1.0 D + 1.0 S (Alt Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Overhang deflection criteria: LL (2L/480) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 7' 1" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 12' 3" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer (V)MEMBER REPORT PASSED Connector: Simpson Strong-Tie Connectors Support Model Seat Length Top Nails Face Nails Member Nails Accessories 2 - Face Mount Hanger HHUS48 3.00"N/A 22-10d 8-10d None Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 2 1/2"N/A 13.0 1 - Uniform (PSF)0 to 3' (Front)1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)3' to 12' 6" (Front)2'15.0 40.0 -Floor - Upper Level 3 - Uniform (PSF)0 to 3' (Front)1'20.0 -35.0 Snow - Porch 4 - Uniform (PLF)0 to 3' 1 3/4" (Front)N/A 80.0 --Wall - Upper Level 5 - Uniform (PSF)0 to 3' (Front)8' 6"20.0 -35.0 Snow - Main 6 - Point (lb)2' 10 1/4" (Front)N/A 2080 -3640 Girder 7 - Point (lb)3' 1 3/4" (Front)N/A 1454 581 1633 Linked from: Flush Beam over Foyer (H), Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 14 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 3 piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"339 -525 864 None 2 - Trimmer - SPF 4.50"4.50"3.17"4373 906 5969 11248 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)10342 @ 5' 10 1/2"14681 (4.50")Passed (70%)--1.0 D + 1.0 S (All Spans) Shear (lbs)564 @ 1' 1/2"16551 Passed (3%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1191 @ 3'14912 Passed (8%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.012 @ 3'0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.019 @ 3'0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 2" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 2" o/c unless detailed otherwise. Main Level, Foyer Entry DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 1 1/2"N/A 13.0 1 - Uniform (PSF)0 to 6' 1 1/2"5'20.0 -35.0 Snow - Porch 2 - Point (lb)5' 9"N/A 4020 906 5422 Linked from: Flush Beam over Foyer (V), Support 1 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 15 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"1.57"1177 2802 73 4052 Blocking 2 - Column - SPF 5.50"5.50"2.15"1952 3506 787 6245 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5458 @ 11' 2"13956 (5.50")Passed (39%)--1.0 D + 1.0 L (All Spans) Shear (lbs)4059 @ 10' 5/8"8590 Passed (47%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)11023 @ 5' 11 15/16"15953 Passed (69%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.242 @ 5' 9 5/8"0.271 Passed (L/538)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.349 @ 5' 9 7/8"0.542 Passed (L/373)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 9' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 6" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer/Dining Room (H)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 6"N/A 13.0 1 - Uniform (PSF)0 to 4' (Front)8' 3"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)4' to 10' 3" (Front)13'15.0 40.0 -Floor - Upper Level 3 - Uniform (PSF)10' 3" to 11' 6" (Front)14'15.0 40.0 -Floor - Upper Level 4 - Uniform (PSF)0 to 4' (Front)3'15.0 40.0 -Floor - Stairs 5 - Point (lb)10' 3" (Front)N/A 824 558 860 Linked from: Flush Beam over Foyer (V), Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 16 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Column - SPF 3.00"3.00"1.50"815 2080 2895 Blocking 2 - Column - SPF 3.00"3.00"1.50"815 2080 2895 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2895 @ 1 1/2"6525 (3.00")Passed (44%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2141 @ 1' 1/2"9595 Passed (22%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)5433 @ 4'8645 Passed (63%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.152 @ 4'0.194 Passed (L/611)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.212 @ 4'0.387 Passed (L/439)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' o/c unless detailed otherwise. Main Level, Beam over PantryMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 8'N/A 8.7 1 - Uniform (PSF)0 to 8' (Front)13'15.0 40.0 Floor - Upper Level Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 17 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None 2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 10" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 9" o/c unless detailed otherwise. Main Level, 16' Garage Door OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 1 - Uniform (PSF)0 to 16' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PLF)0 to 16' 9"N/A 100.0 -Wall - Gable Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 18 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None 2 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1197 @ 1 1/2"3825 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)872 @ 1' 2 1/4"3493 Passed (25%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2470 @ 4' 4 1/2"5306 Passed (47%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.025 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.064 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, 8' Garage Door OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 1 - Uniform (PSF)0 to 8' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PLF)0 to 8' 9"N/A 100.0 -Wall - Gable Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 19 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"448 45 198 691 None 2 - Trimmer - SPF 1.50"1.50"1.50"315 45 130 490 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)646 @ 0 1913 (1.50")Passed (34%)--1.0 D + 1.0 S (All Spans) Shear (lbs)116 @ 1' 4 1/4"2872 Passed (4%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)269 @ 1' 7/16"3946 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.001 @ 1' 1"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Bath WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 2' 3"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 2' 3"1'100.0 --Wall - Gable 4 - Uniform (PSF)3" to 2' 3"3'20.0 -35.0 Snow - Main 5 - Point (lb)3"N/A 188 -118 Linked from: Owner's Bath Window, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 20 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"581 370 540 1491 None 2 - Trimmer - SPF 1.50"1.50"1.50"581 370 540 1491 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1263 @ 0 1913 (1.50")Passed (66%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)529 @ 10 3/4"2872 Passed (18%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)974 @ 1' 6 1/2"3946 Passed (25%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.006 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 1" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Garage Mudroom Service DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 1 - Uniform (PSF)0 to 3' 1"6'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 3' 1"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 1"9'20.0 -35.0 Snow - Main 4 - Uniform (PSF)0 to 3' 1"1'20.0 -35.0 Snow - Garage Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 21 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"426 65 171 662 None 2 - Trimmer - SPF 1.50"1.50"1.50"426 65 171 662 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)603 @ 0 1913 (1.50")Passed (32%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)270 @ 10 3/4"2872 Passed (9%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)490 @ 1' 7 1/2"3946 Passed (12%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.001 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.003 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Great Room Side Windows (2)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 7.0 1 - Uniform (PSF)0 to 3' 3"1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 3' 3"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 3"3'20.0 -35.0 Snow - Main 4 - Uniform (PSF)0 to 3' 3"1'100.0 --Wall - Gable Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 22 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None 2 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1501 @ 0 1913 (1.50")Passed (78%)--1.0 D + 1.0 L (All Spans) Shear (lbs)694 @ 10 3/4"2498 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1251 @ 1' 8"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.007 @ 1' 8"0.111 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.009 @ 1' 8"0.167 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 4" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 4" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Mudroom OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 4"N/A 7.0 1 - Uniform (PSF)0 to 3' 4"16' 3"15.0 40.0 Floor - Upper Level Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 23 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"438 1120 1558 None 2 - Trimmer - SPF 1.50"1.50"1.50"841 2075 2916 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2916 @ 2' 9"3263 (1.50")Passed (89%)--1.0 D + 1.0 L (All Spans) Shear (lbs)807 @ 1' 10"9595 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1346 @ 1' 8 3/4"8645 Passed (16%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.009 @ 1' 5 3/16"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.013 @ 1' 5 3/16"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c unless detailed otherwise. Lower Level, Bath DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 8.7 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level 2 - Uniform (PLF)2' 3" to 2' 9"N/A 90.0 -Wall - Main Level 3 - Uniform (PSF)2' 3" to 2' 9"16' 3"15.0 40.0 Floor - Upper Level 4 - Point (lb)2' 3"N/A 418 1083 Linked from: Mudroom Opening, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 24 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.55"550 1429 1979 None 2 - Trimmer - SPF 3.00"3.00"1.55"550 1429 1979 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1979 @ 1 1/2"3825 (3.00")Passed (52%)--1.0 D + 1.0 L (All Spans) Shear (lbs)990 @ 1' 1/4"2498 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1781 @ 2' 1/2"3431 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.012 @ 2' 1/2"0.128 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.017 @ 2' 1/2"0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 1" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 1" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Lower Level, Beam over Hallway/Mech RoomMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 1"N/A 7.0 1 - Uniform (PSF)0 to 4' 1" (Front)17' 6"15.0 40.0 Floor - Main Level Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 25 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.29"1144 1776 2920 None 2 - Trimmer - SPF 3.00"3.00"2.26"1101 1776 2877 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2919 @ 1 1/2"3825 (3.00")Passed (76%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1439 @ 4' 5 3/4"2498 Passed (58%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2398 @ 2' 8 15/16"3431 Passed (70%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.027 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.045 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Lower Level, Bedroom #5 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"7' 6"15.0 40.0 Floor - Main Level 2 - Uniform (PSF)0 to 5' 6"1'90.0 -Wall - Main Level 3 - Uniform (PSF)0 to 7 1/2"9' 6"15.0 40.0 Floor - Upper Level 4 - Uniform (PSF)0 to 7 1/2"1'80.0 -Wall - Upper Level 5 - Uniform (PSF)4' 10 1/2" to 5' 6"9' 6"15.0 40.0 Floor - Upper Level 6 - Uniform (PSF)4' 10 1/2" to 5' 6"0 80.0 -Wall - Upper Level 7 - Point (lb)7 1/2"N/A 430 713 Linked from: Kitchen Window, Support 1 8 - Point (lb)4' 10 1/2"N/A 430 713 Linked from: Kitchen Window, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 26 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 1 1/2" x 9 1/2" 1.5E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.40"2143 3084 803 6030 None 2 - Trimmer - SPF 3.00"3.00"1.50"1005 2016 41 3062 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5227 @ 1 1/2"6525 (3.00")Passed (80%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2481 @ 1' 1/2"9595 Passed (26%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4765 @ 3' 1 3/16"8645 Passed (55%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.086 @ 3' 2 1/2"0.208 Passed (L/868)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.131 @ 3' 2 3/8"0.313 Passed (L/571)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. Lower Level, Family Room Patio DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 8.7 1 - Uniform (PSF)0 to 6' 6"8'15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 6' 6"1'90.0 --Wall - Main Level 3 - Uniform (PSF)0 to 6' 6"7'10.0 40.0 -Floor - Deck 4 - Uniform (PSF)0 to 6"8'15.0 40.0 -Floor - Upper Level 5 - Uniform (PLF)0 to 6"N/A 80.0 --Wall - Upper Level 6 - Uniform (PSF)0 to 6"15'20.0 -35.0 Snow - Main 7 - Point (lb)6"N/A 1022 1040 581 Linked from: Dining Room Patio Door, Support 2 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 27 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.95"3304 3012 2479 8795 None 2 - Trimmer - SPF 3.00"3.00"1.99"3265 3810 1924 8999 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)7566 @ 8' 4 1/2"11419 (3.00")Passed (66%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)6927 @ 1' 1/2"10898 Passed (64%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)15389 @ 3' 5 1/4"20312 Passed (76%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.167 @ 4' 2 1/2"0.275 Passed (L/592)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.300 @ 4' 2 1/2"0.412 Passed (L/330)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c unless detailed otherwise. Lower Level, Family Room WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 14.5 1 - Uniform (PSF)0 to 8'8' 3"15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 8' 6"1'90.0 --Wall - Main Level 3 - Point (lb)8'N/A 372 990 -FLR Girder 4 - Uniform (PSF)8' to 8' 6"3'15.0 40.0 -Floor - Main Level 5 - Point (lb)2' 4"N/A 2513 1566 2799 Linked from: Great Room Window Rear, Support 2 6 - Point (lb)6' 2"N/A 1783 1566 1604 Linked from: Great Room Window Rear, Support 3 Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 28 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"469 894 1363 None 2 - Trimmer - SPF 1.50"1.50"1.50"469 894 1363 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1362 @ 0 1913 (1.50")Passed (71%)--1.0 D + 1.0 L (All Spans) Shear (lbs)475 @ 10 3/4"2498 Passed (19%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)937 @ 1' 4 1/2"3431 Passed (27%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.005 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Lower Level, WIC DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by IDR; plan dated 12/11/2018. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 7.0 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level 2 - Uniform (PLF)0 to 2' 9"N/A 90.0 -Wall - Main Level Forte v5.4, Design Engine: V7.1.1.3 1/24/2019 11:08:16 AM Page 29 of 29 17851 Element Ave, Lakeville, MN.4te Forte Software Operator Jeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com Job Notes Topaz - TPZLL794 17851 Element Ave, Lakeville, MN Payton XL 1/24/2019; #23342 0 2 / 1 2 / 1 9 X K P