HomeMy WebLinkAboutLA167332 - 19475 Iteri Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 4 :4 9 A M 00 T i t l e S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 S C O L E S R E S I D E N C E 19475 ITERI AVE. LAKEVILLE, MN 55044 Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 03/13/2019dmathews First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" L o w e r L e v e l W i n d o w H e i g h t 8 ' - 0 " U p p e r L e v e l W i n d o w H e i g h t 8 ' - 0 " M a i n L e v e l W i n d o w H e i g h t 9 ' - 0 " 9 ' - 1 1 /8 " 2 ' - 0 3 /4 " 1 0 ' - 1 1 /8 " 1 ' - 8 1 /4 " 9 ' - 0 " Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" S t e p p e d 2 n d L e v e l W i n d o w H e i g h t 8 ' - 0 " Garage T.O.F. - 1' - 8 1/4" 9 ' - 1 1 /8 " 2 ' - 0 3 /4 " 1 0 ' - 0 3 /8 " A A A A B B B B C C D C 2 14/" STONE CAP 5/4" x 8" TRIM 5/4" x 12" TRIM 5/4" x 8" TRIM 10" STONE LINTEL SEE DETAIL 2/09 78" C C 3 8 1 /8 " 3 6 " 8" 3 8 1 /8 " 3 6 " 8" 114" SEE DETAIL 2/09 D D 7 2 " 1 8 " 17" 30" 30" 11 15/16" 8 4 " 1 8 " 17" 30" 30" 30" 30" 30" 30" 23 1/4" 23 1/4" 1 8 " 8 4 " 8x8 COLUMNS w/COMPOSITE WRAP 2x2 TRIM w/5/4" x 8" TRIM G a r a g e W i n d o w H e i g h t 7 ' - 6 " WESTERN CEDAR DECORATIVE GABLE VENTS WESTERN CEDAR DECORATIVE GABLE VENTS 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 10" TRIM 2 4 "18" 18" ENTRY DOOR TO MATCH CEDAR SIDING COLOR 2 4 " A A A A A A B B B B E E E E E E B B 3 6 " 3 8 1 /8 " 8" C 132" 6 0 5 /8 " 36" 36" 36" 4 9 7 /8 " 42" 72" 42" 42" 72" 42" 2 8 3 /4 " 1 5 1 /2 " 42" 72" 5/4" x 8" TRIM SEE DETAIL 2/09 5/4" x 6" TRIM 5/4" x 8" TRIM 2x2 TRIM w/5/4" x 8" TRIM 5/4" x 12" TRIM 5/4" x 6" TRIM 5/4" x 6" TRIM 2x2 TRIM w/5/4" x 8" TRIM 5/4"x4 TRIM w/5/4" x 12" TRIM C E 2x2 TRIM w/5/4" x 8" TRIM B D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 4 :5 5 A M 01 F r o n t & R e a r E l e v a t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 TYPICAL EXTERIOR MATERIALS SQ FT BREAKDOWN SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE 4" EXPOSURE HARDIELAP SIDING PER ELEVATION HARDIEPANEL SMOOTH PER ELEVATION 7" EXPOSURE #1 RED WESTERN CEDAR SIDING PER ELEVATION STONE VENEER PER ELEVATION HARDIEBOARD AND BATTEN w/BATTENS @ 12" O.C. INSTALL KICK OUT FLASHING & TWO MEMBRANE TAR PAPER BACKING IN ALL STONE AREAS 199 SERIES METAL CORNERS PER ELEVATION 1x10 HARDIE TRIM FASCIA PER ELEVATION COMPOSITE VENTED SOFFITS PER ELEVATION EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR B C D A STONE ATTACHMENT 1. VERIFY COMPLIANCE WITH INSPECTOR WHEN PAPER IS COMPLETE IN ONE WINDOW AREA. 2. WEATHER RESISTIVE BARRIERS: INCLUDE 2 LAYERS OF GRADE D PAPER WITH WEATHER RESISITVE BARRIERS OVER WOOD BASED SHEATHING. 15 OR 15# IS NOT GRADE D PAPER. LAP VERTICAL JOINTS IN PAPER AT LEAST 2 INCHES. 3. EXTERIOR OPENINGS FLASHED: FLASH ALL EXTERIOR OPENINGS. THE NAILING FLANGE ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE MANUFACTURERS INSULATION INSTRUCTIONS ARE PROVIDED ON SITE STATING THE FLANGE IS ACCEPTABLE AS FLASHING. 4. WINDOW FLANGES: INSTALL PAPER ON BOTTOM AND SIDES OF WINDOW BEFORE INSTALLING WINDOW. PAPER LOCATED ON TOP OF WINDOW SHALL GO OVER THE WINDOW FLASHING. INSTALL A SECOND LAYER OF PAPER OVER SIDE WINDOW FLANGES. 5. WINDOW OPENINGS: WATERPROOF WINDOW OPENINGS WITH CAULK, TAPE, OR LIKE MATERIAL. ALL OTHER OPENINGS MUST BE WATERPROOFED WITH CAULK, TAPE, OR LIKE MATERIAL. 6. PAPER ENTIRE WALL: BUILDING PAPER MUST BE INSTALLED ON ALL EXTERIOR WALLS INCLUDING WITHIN THE SOFFIT. INSTALL PAPER IN SHINGLE FASHION TO ENSURE PROPER WATER DRAINIAGE. 7. FLASHING: AT ALL WALL/ROOF INTERSECTIONS WHERE ROOF LINE DOES NOT EXTEND PAST WALL, KICKOUT FLASHING IS REQUIRED. ALL OTHER OPENINGS MUST BE FLASHED TO ENSURE PROPER WATERPROOFING. 8. WEEP SCREED: PROVIDE A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 - 1/2" AT OR BELOW THE FOUNDATION PLATE. TO ENSURE TRAPPED WATER HAS PROPER DRAINAGE TO EXTERIOR, SCREED SHALL BE A TYPE THAT ALLOWS FOR DRAINAGE AND MUST BE PLACED A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE CONCRETE. PLACE WEEP SCREEDS JUST BELOW PLATE LINE. IF PAPER HAS BEEN INSTALLED ON FOUNDATION, EXTEND WEEP SCREED ONTO FOUNDATION. ALL STONE MUST NOT EXTEND BELOW, BUT MUST COVER, ALL LATH AND PAPER. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR STONE INSTALLATION OR WATERPROOFING TECHNIQUES. REFER TO MANUFACTURER AND INSTALLERS FOR PREFERRED INSTALLATION METHODS WHICH WILL DIFFER FROM WHAT IS SHOWN. 1/4" = 1'- 0" 1 Front Elevation 1/4" = 1'- 0" 2 Rear Elevation E 3PLY 1-3/4" X 5-1/2" LSL AT 16" O.C. 2PLY 2X6 TRIMMERS 5-1/4" X 11-7/8" PSL POSTS 5-1/4" X 7" PSL HEADER 5-1/4" X 7" PSL HEADER A A A A A B B B B B D D E E E 30" 30" 30" 1 8 " 28" 28" 1 8 " C 5/4" x 8" TRIM 8 x 8 C O L U M N S w /C O M P O S I T E W R A P 2x2 TRIM w/5/4" x 8" TRIM 5/4" x 6" TRIM 5/4" x 6" TRIM 5/4" x 8" TRIM 2x2 TRIM w/5/4" x 8" TRIM 5/4" x 12" TRIM 8 x 8 C O L U M N S w /C O M P O S I T E W R A P A A A A A B C C C E D E 3 6 " 3 8 1 /8 " 8" C 7 3 1 /8 " 36" 36" 36" 5/4" x 8" TRIM 5/4" x 12" TRIM 2x2 TRIM w/5/4" x 8" TRIM 2x2 TRIM w/5/4" x 8" TRIM B B WESTERN CEDAR DECORATIVE GABLE VENTS WESTERN CEDAR DECORATIVE GABLE VENTS 3 8 1 /8 " 3 6 " 8" 6 "6 " 11' - 0" 4 ' - 6 "6 " 6 " 6" 6" 30" 12" 1 2 " 1 2 ' - 0 " 24" 2 4 " 24" 2 4 " 2 4 " 10' - 0" 30' - 6" 4 ' - 0 " 9' - 6" 6' - 6" 6 " 2 4 " 2 4 " 2 4 " 24" 6 " 6" 3' - 0" 15' - 5 1/2" 3' - 0" 6" 6" 7 2 " 7 2 " 7 2 " 24" 35 1/2" 8 ' - 0 1 /2 " 2 5 ' - 1 1 1 /2 " 1 2 ' - 0 " ENGINEERING ROOF TRUSSES PER MFG. SPEC. MANUFACTURE WILL PROVIDE ALL ENGINEERING DRAWING AND SPECIFICS OVERHANG DIMENSIONS ARE TO FACE OF FRAMING ICE AND WATER ALL ADJOINING ROOFS NOTE: RIDGE VENT 14:12 SLOPE 1/4":12 SLOPED SADDLE RIDGE VENT RIDGE VENT R I D G E V E N T 6:12 SLOPE SADDLE 7:12 SLOPE CRICKET 5:12 SLOPE SADDLE 6 1 /2 " / 1 2 " 1 4 " / 1 2 " 1/4" / 12" 1/4" / 12" 1/4" / 12" 16" / 12" 16" / 12" 4 1 /4 " / 1 2 " 16" / 12" 16" / 12" 7 " / 1 2 " 7 " / 1 2 " 7 " / 1 2 " 6 1 /2 " / 1 2 " 16" / 12" 16" / 12" 7" / 12" 7" / 12" 7" / 12" 14:12 SLOPE 8 " / 1 2 " 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 24" 12" 24" 24" 3 8 1 3 /1 6 " 30" 1 9 9 1 /1 6 " 2 4 " 2 4 " 24" D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 1 A M 02 L e f t & R i g h t E l e v a t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 1/4" = 1'- 0" 1 Left Elevation 1/4" = 1'- 0" 2 Right Elevation TYPICAL EXTERIOR MATERIALS SQ FT BREAKDOWN SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS STONE ATTACHMENT 1. VERIFY COMPLIANCE WITH INSPECTOR WHEN PAPER IS COMPLETE IN ONE WINDOW AREA. 2. WEATHER RESISTIVE BARRIERS: INCLUDE 2 LAYERS OF GRADE D PAPER WITH WEATHER RESISITVE BARRIERS OVER WOOD BASED SHEATHING. 15 OR 15# IS NOT GRADE D PAPER. LAP VERTICAL JOINTS IN PAPER AT LEAST 2 INCHES. 3. EXTERIOR OPENINGS FLASHED: FLASH ALL EXTERIOR OPENINGS. THE NAILING FLANGE ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE MANUFACTURERS INSULATION INSTRUCTIONS ARE PROVIDED ON SITE STATING THE FLANGE IS ACCEPTABLE AS FLASHING. 4. WINDOW FLANGES: INSTALL PAPER ON BOTTOM AND SIDES OF WINDOW BEFORE INSTALLING WINDOW. PAPER LOCATED ON TOP OF WINDOW SHALL GO OVER THE WINDOW FLASHING. INSTALL A SECOND LAYER OF PAPER OVER SIDE WINDOW FLANGES. 5. WINDOW OPENINGS: WATERPROOF WINDOW OPENINGS WITH CAULK, TAPE, OR LIKE MATERIAL. ALL OTHER OPENINGS MUST BE WATERPROOFED WITH CAULK, TAPE, OR LIKE MATERIAL. 6. PAPER ENTIRE WALL: BUILDING PAPER MUST BE INSTALLED ON ALL EXTERIOR WALLS INCLUDING WITHIN THE SOFFIT. INSTALL PAPER IN SHINGLE FASHION TO ENSURE PROPER WATER DRAINIAGE. 7. FLASHING: AT ALL WALL/ROOF INTERSECTIONS WHERE ROOF LINE DOES NOT EXTEND PAST WALL, KICKOUT FLASHING IS REQUIRED. ALL OTHER OPENINGS MUST BE FLASHED TO ENSURE PROPER WATERPROOFING. 8. WEEP SCREED: PROVIDE A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 - 1/2" AT OR BELOW THE FOUNDATION PLATE. TO ENSURE TRAPPED WATER HAS PROPER DRAINAGE TO EXTERIOR, SCREED SHALL BE A TYPE THAT ALLOWS FOR DRAINAGE AND MUST BE PLACED A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE CONCRETE. PLACE WEEP SCREEDS JUST BELOW PLATE LINE. IF PAPER HAS BEEN INSTALLED ON FOUNDATION, EXTEND WEEP SCREED ONTO FOUNDATION. ALL STONE MUST NOT EXTEND BELOW, BUT MUST COVER, ALL LATH AND PAPER. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR STONE INSTALLATION OR WATERPROOFING TECHNIQUES. REFER TO MANUFACTURER AND INSTALLERS FOR PREFERRED INSTALLATION METHODS WHICH WILL DIFFER FROM WHAT IS SHOWN. 1/8" = 1'- 0" 3 Roof Plan ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE 4" EXPOSURE HARDIELAP SIDING PER ELEVATION HARDIEPANEL SMOOTH PER ELEVATION 7" EXPOSURE #1 RED WESTERN CEDAR SIDING PER ELEVATION STONE VENEER PER ELEVATION HARDIEBOARD AND BATTEN w/BATTENS @ 12" O.C. INSTALL KICK OUT FLASHING & TWO MEMBRANE TAR PAPER BACKING IN ALL STONE AREAS 199 SERIES METAL CORNERS PER ELEVATION 1x10 HARDIE TRIM FASCIA PER ELEVATION COMPOSITE VENTED SOFFITS PER ELEVATION EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR B C D A E 5-1/4" X 11-7/8" PSL POSTS 5-1/4" X 7" PSL HEADER 5-1/4" X 7" PSL HEADER 5-1/4" X 7" PSL HEADER 3PLY 1-3/4" X 5-1/2" LSL AT 16" O.C. 3PLY 1-3/4" X 5-1/2" LSL AT 16" O.C. 2PLY 2X6 TRIMMERS UP UP 20' - 0" 16' - 0" 18' - 0" 16' - 0" 70' - 0" 70' - 0" 11' - 2 3/4" 8' - 9 1/4" 8' - 0" 8' - 0" 4' - 3" 7' - 5" 6' - 4" 2' - 0" 11' - 10" 10' - 0" 13' - 6" 1' - 9 3/4" M.O. 18' - 3" 1' - 7 1/4" 1' - 10 1/2" M.O. 9' - 3" 1' - 10 1/2" 35' - 4" 21' - 8" 13' - 0" 70' - 0" 1 2 ' - 0 " 6 ' - 0 " 6 ' - 0 " 2 8 ' - 2 " 1 2 ' - 0 " 7 ' - 1 0 " 5 2 ' - 2 " 6 ' - 0 " 2 ' - 0 " 4 2 ' - 0 " 4 ' - 0 " 1 2 ' - 0 " 6 ' - 2 3 /4 " 5 ' - 9 1 /4 " 2 ' - 2 1 /2 " 1 ' - 9 1 /2 " 9 ' - 4 " M .O . 3 ' - 3 " 2 9 ' - 5 " 3 ' - 6 " 4 ' - 6 " 1 4 ' - 2 " 21' - 0" 4' - 6" 9' - 0" 8' - 7" 9' - 5" 15' - 10" 7 ' - 1 0 " 1 4 ' - 6 " 7 ' - 5 1 /2 " 1 3 ' - 4 1 /2 " 4 ' - 0 " 3 ' - 1 0 " 10' - 0" 1' - 10" 6" 6 0 ' - 0 " 6 ' - 0 " 6" 6" 6 ' - 8 3 /4 " 5 ' - 7 1 /2 " 4 ' - 0 1 /2 " 1 7 ' - 9 1 /4 " 5 1 " 4 8 " 5' - 0" 5' - 6" 2' - 10 1/4" 17' - 9" 5' - 0" 8' - 4 1/4" 17' - 9" 4' - 8" 8' - 11 3/4" 7 ' - 1 0 3 /4 " 5 ' - 1 1 " 3 ' - 3 1 /2 " 3 ' - 1 0 1 /2 " 4 ' - 8 1 /4 " 5 1 /2 " 35' - 9 1/4" 6' - 5 1/2" 1' - 7 1/2" 3 0 " 50 1/2" 42" 63 1/2" 2 4 " 1 1 4 " 5 4 " 8 4 " 44 1/2" 48" 4' - 8 3/4" 8' - 7 1/2" 49" FRONT PORCH FND WALL: 3'- 6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE - UNEXCAVATED - 36"x36"x12" CONC. PAD (TYPICAL) 2 X 6 P L U M B I N G W A L L GARAGE FND WALL: 3'- 6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE DECK COLUMNS: 3/4" COMPOSITE WRAP 6x6 TRD. POST ON 18" SONO TUBE @ 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL DIMENSIONS ARE TO EDGE OF CONCRETE AND EDGE OF FRAMING FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C. FLOOR SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 8'- 10" UNLESS NOTED SET WINDOW HDRS @ 96" FROM CONCRETE FLOOR UNLESS NOTED NOTE: - UNEXCAVATED - EXPOSED TREADS & RISERS STAIRS WOOD RAILING WINE RM TILE GLASS PANELS 30"x80" GLS DR GLASS PANELS EXERCISE ROOM RUBBER TILES 36"x80" OPENING w/38"x84" BARN DOOR S T O R A G E C A B I N E T ARCADE GAMES WOOD FD WH FURN 3 2 "x 8 0 " D O O R MECHANICAL ROOM CONCRETE SUMP w/ SEALED COVER 5' - 6 3/4" 13' - 8 1/2" 5' - 0 3/4" R&S SMOKE DET. GUEST BEDROOM CARPET 30"x80" DOOR SD/CO 6 0 "x 8 0 "D B L D R FAN 4 2 " V A N I T Y 3 4 "x 6 0 " F B R G L S S H O W E R BATH TILE 2 8 "x 8 0 " D O O R FAN B E N C H & H O O K S GAME ROOM WOOD FAMILY ROOM WOOD E N T E R T A I N M E N T C E N T E R WET BAR WOOD S N K I S L A N D D W SCREEN PATIO CONCRETE UNDERDECKING MAIN FND WALL: 9'- 0"x8" POURED CONC. FOUNDATION ON 20"X8" CONCRETE FOOTING REBAR PER CODE INTERIOR THERMAL WALL: (UNEXPOSED WALLS ONLY) 1" AIRSPACE 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. INTERIOR THERMAL WALL: (EXPOSED WALLS ONLY) 1" RIGID INSULATION (R - 5) 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. EXTERIOR THERMAL WALL: 2" RIGID INSULATION SYSTEM (R - 10) APPLIED TO EXTERIOR PROVIDE FLASHING WALK OUT WALL: 2X6 STUDS @ 16" O.C. 3'- 6"x10" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE PROVIDE 3 1/2"x5 1/2" POUR ON TOP OF 10" WALL UNDER 2X6 WALL SCREEN PATIO FND WALL: 3'- 6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE 36"x36"x12" CONC. PAD (TYPICAL) 2 x 1 2 J O I S T S @ 1 6 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 1 8 " F L O O R T R U S S E S @ 1 9 .2 " O .C . STAIR FOOTING: 12" SONO TUBE @ 42" BELOW GRADE INTERIOR BEARING WALLS: 4X6 TREATED WOOD 16"X8" FOOTING (TYPICAL) W.O. W .O . W.O. W.O. W .O . SIMPSON METAL TIES: END JOISTS TO BEAM - LUC21OZ POST TO FOOTING - ABW66Z POST TO BEAM - LPC6Z MIDDLE JOISTS - LUS21OZ DECK RIM TO HOUSE - 3/8"x5 - 1/2" COATED LAG BOLTS & WASHERS NOTE: SOLID BLOCK ALL JOIST SPACES FIRE CAULK ALL PENETRATIONS IN SOLID BLOCK 2X6 WALL 2 X 6 W A L L 2X6 WALL 2X6 BEARING WALL 2X6 BRG WALL SOLID BEARING TYPICAL SOLID BEARING TYPICAL BEAM PER MFG. SPEC DROPPED BEARING POINT FROM MAIN LEVEL BEAM PER MFG. SPEC DROPPED BEAM PER MFG. SPEC FLUSH ALLOW FOR HVAC B E A M P E R M F G . S P E C F L U S H BEAM PER MFG. SPEC FLUSH BEAM PER MFG. SPEC FLUSH 2x12 JOISTS @ 16" O.C. 8" 8 " 8" 8 " 8" 8 " 8" 8 " 8" 8 " 10" 8 " 8" 8 " 8" 1 0 " 10" 8 " 8" 8 " 10" OPEN TO ABOVE 2 06 1 06 1 08 1 09 3 07 3 08 3 06 3 09 2 08 4 09 2 07 4 10 F L O A T I N G S H E L V E S 3 0 " F R E Z . 3 0 " R E F I G . F U L L H E I G H T F N D W A L L 8 ' - 0 " 1 07 3 6 "x 8 4 " C .O . 17'- 3"x7'- 0" C.O. 2 4 " 19 1/4" 97" FND FOR STEPS DROPPED CLG. AREA FOR HVAC CHASE FWH3'- 6"x8'- 0"AR BEAM PER MFG. SPEC. P3560 BEAM PER MFG. SPEC. P6060 BEAM PER MFG. SPEC. F W H 9 '- 0 "x 8 '- 0 " O X O B E A M P E R M F G . S P E C . FWH2'- 8"x8'- 0"AL BEAM PER MFG. SPEC. 2)CXW16 BEAM PER MFG. SPEC. STACKED W/D CXW16 BEAM PER MFG. SPEC. 28"x80" PKT DR 8' CLG. 8' CLG. 15' - 10" 2' - 0" 5' - 0" INT. DRINK LEDGE 244GW5050 (200 SERIES) BEAM PER MGF. SPEC. 6 " 27 3/4" 136 1/2" 25" C15 FX C15 FX EXT. SERVING LEDGE METAL FLASHING 5/4" x 6" TRIM 2" RIGID INSULATION 2X2 BLOCKING LAP SIDING 1/2" SHEATHING 2X6 SILL PLATE 1/2" ANCHOR BOLT 2 " BUILDING PAPER 2X6 SILL PLATE NOTE: ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR. FLOOR TRUSSES PER PLAN NOTE: FOUNDATION WALL SIZE MAY VARY PER PROJECT. SEE FOUNDATION PLAN 2X6 SOLE PLATE INSULATION PER CODE 2X6 STUDS @ 16" O.C. 1/2" GYP. BRD. DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE. NOTE: 5 1/2" 4 1/2" 10" 3 1 /2 " 2 " I N S U L A T I O N 2" INSULATION @ 45 DEGREE ANGLE 4" SAND 10" WALKOUT WALL NOTE: ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR. NOTE: LAP SIDING PER PLAN BUILDING PAPER 1/2" PLYWOOD 2X6 STUDS @ 16" O.C. INSULATION PER CODE METAL FLASHING 1/2" GYP. BRD. 1/2" ANCHOR BOLT 2X6 SILL PLATE DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE. NOTE: D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 1 A M 03 L o w e r L e v e l S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 1" = 1'- 0" 2 Floor Detail - 2x6 Sill Plate 1" = 1'- 0" 3 Floor Detail - 10" Walkout Wall 2PLY 9-1/2" LVL 2 PLY 11-7/8" LVL FLUSH 5-1/2" X 5-1/2" GLU-LAM 5-1/2" X 5-1/2" GLU-LAM 3PLY 16" LVL 2PLY 11-7/8" LVL 2PLY 11-7/8" LVL 5-1/4" X 11-7/8" NO ROOF LOAD. 5-1/4" X 16" TREATED GLU- LAM NO SUPPORT POST RIGHT SIDE OF DOOR. TOO MUCH UPLIFT WILL OCCUR. 2PLY 9-1/2" LVL 2PLY 9-1/2" LVL 2PLY 9-1/2" LVL W16X45 STEEL BEAM 7.035" WIDE X 16.13" DEEP 7-1/8" X 7-1/2" GLU-LAM 7-1/8" X 7-1/2" GLU-LAM 12" O.C. Max for spans TEMPER CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. UP DN DN DN 11' - 2 3/4" 8' - 9 1/4" 8' - 0" 8' - 0" 4' - 0 1/2" 21' - 11 1/2" 8' - 0" 20' - 0" 16' - 0" 34' - 0" 70' - 0" 1 9 ' - 0 " 1 2 ' - 0 1 /2 " 1 0 ' - 1 1 1 /2 " 4 6 ' - 0 " 2 ' - 0 " 6 ' - 0 " 1 2 ' - 0 " 4 ' - 0 " 4 4 ' - 0 " 4 ' - 0 " 4 ' - 0 " 3 ' - 3 1 /2 " 2 ' - 8 1 /2 " 3 ' - 0 " 3 ' - 0 " 5 ' - 2 3 /4 " 7 ' - 9 1 /4 " 1 2 ' - 0 " 3 ' - 0 " 5 ' - 9 1 /4 " 6 ' - 2 3 /4 " 1 2 ' - 0 " 2 8 ' - 0 " 6 ' - 0 " 6 ' - 0 " 8 ' - 0 " 6 ' - 0 " 6 0 ' - 0 " 12' - 0" 10' - 0" 13' - 6 1/2" 21' - 5 1/2" 13' - 0" 6' - 3" 5' - 9" 5' - 2 3/4" 4' - 9 1/4" 4' - 10 1/2" 8' - 8" 1' - 8 3/4" 18' - 0" 1' - 8 3/4" 2' - 0" 9' - 0" 2' - 0" 35' - 6 1/2" 34' - 5 1/2" 1 4 ' - 6 1 /2 " 8 ' - 0 " 7 ' - 5 1 /2 " 1 4 ' - 0 " 8' - 6 1/2" 7' - 8" 1' - 9 1/2" 4' - 8 1/2" 4' - 9" 4 1/2" 4 1/2" 4 1 /2 " 4 1 /2 " 6" 6" 3 " 3 " 3" 3" 3" 3 " 3 " 3" 3" 3 " 10' - 0" 2' - 0" 20' - 6" 6" 9' - 0" 6 ' - 1 3 /4 " 5 ' - 8 1 /2 " 6 ' - 1 3 /4 " 24" 3 ' - 6 " 4 ' - 6 " 1 4 ' - 8 " B U I L T - I N G R I L L GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C. FLOOR SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 10'- 1 1/8" UNLESS NOTED SET WINDOW HDRS @ 108" FROM MAIN LEVEL UNLESS NOTED NOTE: SCREEN PORCH COMPOSITE DECKING PINE T&G CLG. VAULTED FRONT PORCH CONCRETE PINE T&G CLG. FLOOR DRAIN TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL 2X6 PLUMBING WALL COLUMN CONSTRUCTION: 8x8 POST w/COMPOSITE WRAP 32"x96" FIRE DR 20 MIN RATED BEAM PER MFG SPEC NOTE: 9'- 0" x 8'- 0" DOOR BEAM PER MFG SPEC BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 1 2 ' - 2 3 /4 " 1 7 ' - 6 1 /2 " 2 ' - 0 " 2 ' - 5 1 /2 " 4 ' - 4 1 /2 " 7 ' - 4 3 /4 " 5 ' - 5 1 /2 " 6 ' - 7 1 /2 " 5 ' - 8 1 /4 " 27 3/4" 10' - 2 3/4" 6' - 5" 7' - 4 1/4" 7 ' - 8 1 /4 " 1 1 ' - 0 " 6 ' - 9 1 /4 " 4' - 8 3/4" 8' - 8" 8' - 10" 13' - 6 1/2" 8' - 6 1/4" 9' - 8 1/2" 33 1/4" 3 3 1 /4 " 6 ' - 0 " 6 ' - 2 3 /4 " foyer WOOD RECESSED CLG w/WD BEAMS 2)18"x84" SIDELITES w/24" TRANSOM BEAM PER MFG SPEC 4 2 "x 8 4 " E N T R Y D R . w /2 4 " T R A N S O M B E A M P E R M F G S P E C 13'- 0"x9'- 0" C.O. DINING WOOD RECESSED CLG. G A S F I R E P L A C E P E R M F G . S P E C S . B U I L T I N 'S GREAT ROOM WOOD RECESSED CLG. w/WD BEAMS 2 4 " 24" B U I L T I N 'S 24" 2 4 " 17'- 0"x9'- 0" C.O. 2 1 " 21" 58" 10" 58" 10" 58" 10" 58" 10" 58" 1 6 2 " 11' - 0" 8 9 1 /2 " 5' - 6 1/2" 2 7 1 /8 " 1 0 " 2 9 1 /2 " 2 7 1 /8 " 1 0 " 2 7 1 /8 " 1 0 " 2 7 1 /8 "STAIRS WOOD EXPOSED TREADS & RISERS RAILING OPEN TO BELOW RAILING 30" FREZ. K I T C H E N W O O D R E C E S S E D C L G w /W D B E A M S SNK DW 2 - BIN TRASH 4 8 " R A N G E H O O D V E N T U P P E R S U P P E R S S N K BUTLER PANTRY WOOD 30" REFIG 18" WINE DBL. OVEN U P P E R S W.I.C. TILE R&S MUD ROOM TILE D R O P Z O N E B E N C H & L O C K E R S HVAC PANTRY WOOD B A S E C A B I N E T S UPPER CABINETS R&S BATH WOOD HALL WOOD OFFICE WOOD B U I L T - I N D E S K60"x 9 6 "D B L . D R 4 8 "x 9 6 "D B L . D R 30"x96" DOOR 30"x96" PKT DR 3 6 "x 9 6 " P K T D R 36"x108" C.O. 3 6 "x 1 0 8 " C .O . 3 6 "x 1 0 8 " C .O . CONCRETE INSULATE WALLS & CEILING GARAGE FLOOR DRAIN 18'- 0" x 8'- 0" DOOR BEAM PER MFG SPEC 36"x96" SERVICE DR. BEAM PER MFG SPEC FAN 44" VANITY G A S F I R E P L A C E P E R M F G . S P E C S . 1 0 '- 0 " x 9 '- 0 " F O L D I N G D O O R B E A M P E R M F G S P E C 3 6 "x 9 6 "S C R N D R SD/CO ROOF TRUSSES @ 24" O.C. ROOF TRUSSES @ 24" O.C. 2 4 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 4 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 4 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 4 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2 4 " F L O O R T R U S S E S @ 1 9 .2 " O .C . 2X6 WALL 2 X 6 W A L L 2 X 6 W A L L 2 X 6 W A L L 2X6 WALL 2X6 BRG WALL B E A M P E R M F G . S P E C F L U S H BEAM PER MFG. SPEC FLUSH ALLOW FOR HVAC BEAM PER MFG. SPEC DROPPED BEAM PER MFG. SPEC DROPPED BEAM PER MFG. SPEC FLUSH BEAM PER MFG. SPEC FLUSH BEAM PER MFG. SPEC FLUSH B E A M P E R M F G . S P E C F L U S H G I R D E R T R U S S P E R M F G . S P E C F L U S H BEAM PER MFG. SPEC FLUSH CONC. BEAM PER MFG. SPEC DROPPED 48" 99" 48" 99" 4 8 " 1 1 1 /2 " 4 8 " STAIR LANDING SUPPORTS BEAM PER MFG SPEC R A I L I N G BEAM PER MFG. SPEC DROPPED 2 06 1 06 1 08 1 09 3 07 3 08 3 06 3 09 2 08 4 09 2 07 4 10 BEAM PER MFG. SPEC FLUSH 8 " P R O J E C T I O N 1 07 2 x 4 L A D D E R T R U S S R A I S E D F L O O R A R E A 8" PROJECTION AXW351 FX P3550 AR351 BEAM PER MFG. SPEC. AXW351 FX P3550 AR351 BEAM PER MFG. SPEC. AXW61 FX P6050 AR61 BEAM PER MFG. SPEC. A 3 5 1 F X P 3 5 5 0 B E A M P E R M F G . S P E C . A 3 5 1 F X P 3 5 5 0 B E A M P E R M F G . S P E C . 3 )C X 1 4 5 F X 3 )A 2 8 1 F X 3 )C X 1 5 F X B E A M P E R M F G . S P E C . 3)A281 FX 3)CX15 FX BEAM PER MFG. SPEC. A281 FX CX15 FX BEAM PER MFG. SPEC. 2)A251 FX 2)CW15 BEAM PER MFG. SPEC. 3)A281 FX 3)CX15 BEAM PER MFG. SPEC. 3 )A 3 1 F X B E A M P E R M F G . S P E C . @ 7 '- 6 " F R O M T .O .F . 2)A31 FX BEAM PER MFG. SPEC. @ 7'- 6" FROM T.O.F. A31 FX CXW14 BEAM PER MFG. SPEC. 3 )A 3 1 F X 3 )C X W 1 5 B E A M P E R M F G . S P E C . A31 FX CXW15 BEAM PER MFG. SPEC. A31 FX CXW15 BEAM PER MFG. SPEC. A51 FX P5050 BEAM PER MFG. SPEC. GIRDER TRUSS PER MFG. SPEC FLUSH 3 6 "x 1 0 8 " C .O . STONE VENEER STONE VENEER 60" 52" 1 2 0 " 4 2 " 4'x4' PAD F X RAILING 1 2 " B E N C H 3 6 " R E F . D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 2 A M 04 M a i n L e v e l S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 2PLY 11-7/8" LVL CORNER TO CORNER 2PLY 16" LVL 3PLY 18" LVL 3PLY 16" LVL 2PLY 9-1/2" LVL 2PLY 9-1/2" LVL 3PLY 11-7/8" LVL 3PLY 16" LVL 2PLY 16" LVL 2PLY 16" LVL 2PLY 16" LVL 2PLY 16" LVL 2PLY 11-7/8" LVL 2PLY 9-1/2" LVL 2PLY 11-7/8" LVL 2PLY 11-7/8" LVL 3PLY 14" LVL 2PLY 11-7/8" LVL 2PLY 16" LVL 3PLY 16" LVL 3PLY 18" LVL 3PLY 18" LVL W16X89 STEEL BEAM 3PLY 24" LVL 5-1/2" X 7" GLU- LAM FOR 3PLY 2PLY 5-1/2" X 5-1/2" GLU-LAM POST 3PLY 16" LVL 5-1/2" X 5-1/2" GLU-LAM POST TEMPER glass within 36" of landing or stair treads. CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF CS-PF Fl o o r G i r d e r DN DN 9' - 2 3/4" 8' - 9 1/4" 8' - 0" 8' - 0" 12' - 3 1/2" 5' - 8 1/2" 13' - 6 1/2" 2' - 5 1/2" 2' - 0" 18' - 0" 16' - 0" 18' - 0" 16' - 0" 70' - 0" 5 ' - 2 3 /4 " 5 ' - 2 3 /4 " 8 ' - 0 " 1 2 ' - 0 " 1 0 ' - 5 1 /2 " 1 7 ' - 6 1 /2 " 1 2 ' - 0 " 6 0 ' - 0 " 6' - 3" 9' - 9" 7' - 0" 7' - 0" 6' - 0 1/2" 2' - 6" 7' - 8 3/4" 7' - 8 3/4" 8' - 10 1/2" 7' - 1 1/2" 16' - 0" 14' - 0" 8' - 6 1/2" 15' - 5 1/2" 16' - 0" 70' - 0" 1 0 ' - 1 1 1 /2 " 1 5 ' - 0 " 1 2 ' - 0 " 1 2 ' - 0 " 1 2 ' - 0 " 2 5 ' - 1 1 1 /2 " 1 0 ' - 0 1 /2 " 6 0 ' - 0 " 6 ' - 0 " 6 ' - 0 " 2' - 0" 2 ' - 0 " 1 0 ' - 0 " 4' - 0" 3' - 0" 6' - 0" 4 1 /2 " 4 1 /2 " 6" 6" 3" 3" 3" 3" 3 " 3 " 3" 3" 3" 3" 3" 4 1/2" 4 1/2" 12" 48" 99" 4 8 " 4 8 " 48" 99" 1 2 " 1 0 7 1 /2 " 6" 6 " 13' - 3" 6' - 11 3/4" 8' - 5 1/2" 7' - 7" 8' - 1" 3' - 11 1/2" 5' - 5 1/2" 16' - 2 3/4" 6' - 11 3/4" 9' - 6 1/2" 9' - 1" 5' - 5" 5' - 5 1/2" 4' - 0 1/2" 16' - 2 3/4" 5' - 4 1/2" 7 ' - 9 1 /4 " 7 ' - 1 " 4 ' - 9 " 1 0 ' - 5 " 5 ' - 8 1 /2 " 3 ' - 1 1 1 /2 " 3 ' - 1 0 1 /2 " 8 ' - 5 1 /4 " 1 2 ' - 3 3 /4 " 2 ' - 6 1 /2 " 4 ' - 9 " 2 ' - 7 1 /2 " 7 ' - 9 1 /2 " 5 ' - 8 1 /2 " 4 ' - 3 1 /4 " 1 3 ' - 1 3 /4 " 7 ' - 4 " 2 ' - 4 1 /2 " 4 ' - 1 0 " 7 ' - 5 1 /2 " 1 2 ' - 1 0 1 /4 " 3 ' - 3 1 /2 " 3 ' - 8 1 /2 " 7 ' - 2 1 /2 " 2 ' - 6 " 2 ' - 6 " 5 ' - 0 1 /2 " 18' - 2 3/4" 8' - 5 1/2" 7' - 7" 4' - 5 1/2" 13' - 3 1/4" HALLWAY CARPET SD/CO SD/CO STAIRS WOOD EXPOSED TREADS & RISERS RAILING OPEN TO BELOW 3)CX16 BEAM PER MFG. SPEC. R&S SMOKE DET. BEDROOM #2 CARPET 3 0 "x 8 0 " D O O R W.I.C. CARPET 30"x80" DOOR U P P E R L E V E L F L O O R T R U S S E S FAN 3 9 " V A N I T Y 34"x60" TILE SHOWER BATH TILE 30"x80" DOOR 28"x80" PKT DR 2 4 "x 8 0 "G L S D R W.I.C. CARPET R&S BEDROOM #3 CARPET SMOKE DET. BATH TILE 30"x60" TUB/SHWR FAN 4 2 " V A N I T Y 3 0 "x 8 0 " D O O R 3 0 "x 8 0 " D O O R 2 8 "x 8 0 " D O O R 4 8 "x 8 0 "D B L D R LINEN SHELVES BEDROOM #4 CARPET W.I.C. CARPET R&S 3 0 "x 8 0 " D O O R 30"x80" DOOR STORAGE RM CARPET KIDZ LOFT CARPET FAN 34"x48" TILE SHWR 54" VANITY BATH TILE 2 8 "x 8 0 " D O O R 3 6 "x 8 0 " D O O R 3 R I S E R S 8 4 "x 9 6 " O P 'N G HER W.I.C. CARPET HIS W.I.C. CARPET B U I L T - I N D R E S S E R 36"x96" PKT DR R&S R&S 5 4 " V A N I T Y 5 4 " V A N I T Y 30"x80" DOOR 30"x80" DOOR 4 8 " L I N E N W.I.SHOWER 6' - 8 1/4" 5 8 1 /4 " 4 3 " 29 1/2" 52" LUXURY BATH TILE S C R E E N P O R C H C H I M N E Y OWNER'S SUITE CARPET VAULTED CLG. 6 0 "x 8 0 "D B L . D R PINNED R O O F T R U S S E S @ 2 4 " O .C . ROOF TRUSSES @ 24" O.C. ROOF TRUSSES @ 24" O.C. R O O F T R U S S E S @ 2 4 " O .C . ROOF TRUSSES @ 24" O.C. R O O F T R U S S E S @ 2 4 " O .C . SMOKE DET. SMOKE DET. WSHR w/ FLOOR DRAIN DRYER A T T I C A C C E S S U P P E R S FAN LAUNDRY TILE 3 2 "x 8 0 " D O O R S N K U P P E R L E V E L F L O O R T R U S S E S 2X6 WALL 2 X 6 W A L L 2 X 6 W A L L 2X6 WALL 2X6 WALL 2 X 6 W A L L 2X6 PLUMBING WALL 2 X 6 P L U M B I N G W A L L 2X6 PLUMBING WALL 2 X 6 P L U M B I N G W A L L 2 X 6 W A L L ROOF TRUSSES ARE CALLED OUT AT 24" O.C. ROOF SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 9'- 1 1/8" UNLESS NOTED SET WINDOW HDRS @ 96" FROM UPPER LEVEL NOTE: NOTE: BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 4 2 "x 9 6 " O P 'N G 1 06 1 08 1 09 3 07 3 08 3 06 3 09 2 08 4 09 2 07 4 10 R A I S E D C O U N T E R - T O P PASS - THRU M I R R O R L'DRY BINS SOLAR TUBE SOLAR TUBE SOLAR TUBE 1 07 S L O P E D C L G . S L O P E D C L G . S L O P E D C L G . S L O P E D C L G . S L O P E D C L G . S L O P E D C L G . SLOPED CLG. CX135 FX BEAM PER MFG. SPEC. 2)CX16 BEAM PER MFG. SPEC. 3)AX41 BEAM PER MFG. SPEC. 3 )C X W 1 6 B E A M P E R M F G . S P E C . A31 FX BEAM PER MFG. SPEC. @ 54" FROM U.L. A31 BEAM PER MFG. SPEC. 3)AXW31 BEAM PER MFG. SPEC. CXW15 BEAM PER MFG. SPEC. A31 BEAM PER MFG. SPEC. C X W 1 4 F X B E A M P E R M F G . S P E C . 5 ' - 8 1 /4 " 6 ' - 3 3 /4 " 3'- 6"x6'- 0" CSMT BEAM PER MFG. SPEC. 3'- 6"x6'- 0" CSMT BEAM PER MFG. SPEC. P6060 BEAM PER MFG. SPEC. 6)CX16 FX BEAM PER MFG. SPEC. L I N E O F C L G H G T C H A N G E 2x6 WALL 3 0 "x 8 0 " O P 'N G 48" TALL SHELVES I S L A N D 18" 3 6 " 3" MIN. ABS OR PVC OR EQUIVALENT GAS TIGHT PIPE SEAL ALL JOINTS BETWEEN SLAB AND FOUNDATION WALL 4" PERFORATED DRAIN TILE W/FILTER FABRIC 8"X16" ROCK TRENCH SEALED SUMP BASKET MIN 6 MIL OR 3 MIL CROSS LAMINATED POLY SHALL BE LAPPED 12" AND PLACED BELOW THE SLAB AND ON TOP OF 4" MIN. SAND GAS PERMEABLE LAYER INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOOR AND IN ACCESSIBLE ATTICS ALL CONTROL JOINTS, ISOLATION JOINTS CONSTRUCTION JOINTS AND ANY OTHER JOINTS IN CONCRETE SLABS SHALL BE SEALED WITH CAULK OR SEALANT SEAL ALL FLOOR OPENINGS ALL PIPE JOINTS AND FITTINGS TO BE GLUED OR TRANSITION COUPLINGS PROVIDE SPACE FOR FUTURE INSTALLATION OF A FAN *MIN. 24' DIAMETER CENTERED ON THE AXIS OR THE VENT STACK *MIN. VERTICAL DISTANCE 36" INSTALL LIVE OUTLET IN ATTIC WHERE FUTURE FAN MAY BE INSTALLED R - 4 MIN. INSULATION AROUND PIPE IN UNCONDITIONED SPACES 2x4 LADDER TRUSS RAISED FLOOR D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 3 A M 05 U p p e r L e v e l S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 NOTE: ANDERSEN WINDOWS (400 SERIES) ARE CALLED OUT BY WINDOW FRAME SIZE IN FEET. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.) ATTENTION: BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION: 1/4" = 1'- 0" 2 Detail - Passive Radon System 1/4" = 1'- 0" 3 Raised Floor Area 2PLY 9-1/2" LVL 2'-0" FAN CS-PF CS-PF CS-PF CS-PF -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). TEMPER if within 60" of floor. -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL SCREEN PATIO UNDERDECKING GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE PARALLEL CHORD ROOF TRUSSES PER MFG. SPEC. 2X12 JOISTS @ 16" O.C. CONTINOUS BEAM PER MFG SPEC SCREEN PORCH COMPOSITE DECKING PINE T&G CLG 6" 4' - 6" 9 ' - 3 " E .H . 1 5 3 /1 6 " 10' - 3" 6 3 /4 " 7 ' - 1 0 7 /8 "FOS 24" 6:12 ROOF SADDLE 7" 12" 7 ' - 2 3 /8 " 9 ' - 1 1 /8 " 1 0 ' - 1 1 /8 " 8' - 0" 8' - 0" 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. 16" 12" 7" 12" 9 1 /4 " E .H . 7 1 3 /1 6 " E .H . 8 1 /1 6 " RECESSED CLG. 24" 132" 24" 8 " LUXURY BATH DINING WET BAR 1 8 " BEAM FLUSH PER MFG. SPEC. 12" 24" 24" First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" 9 ' - 0 " 3 ' - 6 " 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL SLOPED CLG. 21" 162" 21" 24" 138 1/2" 24" 27 1/8" 10" 27 1/8" 10" 27 1/8" 10" 27 1/8" 8 "8 " 8 ' - 1 0 " 1 0 ' - 1 1 /8 " 9 ' - 1 1 /8 " V A U L T E D C L G A P E X 1 1 ' - 2 3 /4 " O P 'N G 1 0 8 " O P 'N G 9 6 " 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. 14" 12" 6 1/2" 12" 3" 12" EXERCISE ROOM FAMILY ROOM FRONT PORCH foyer GREAT ROOM BEDROOM #2 OWNER'S SUITE RECESSED CLG. 8" WOOD B'M RECESSED CLG. 8" WOOD B'M BEAM FLUSH PER MFG. SPEC. BEAM FLUSH PER MFG. SPEC. BEAM DROPPED PER MFG. SPEC. BEAM DROPPED PER MFG. SPEC. 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 2 4 " 24" 8' - 0" 6' - 0" 7 1 /4 " 1 0 ' - 1 1 /8 " 1 0 ' - 8 3 /8 " 12' - 0" 10' - 0" 4' - 0" 14' - 0" 6" 12" 24" 9 ' - 1 1 /8 " GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE CANTILEVER INSULATION: SPRAY FOAM INSULATION R - 30 MIN. 24" E .H . 6 7 /8 " 7" 12" 10' - 3" 10' - 3" 9 ' - 3 " 8 ' - 0 " V A U L T E D C L G . A P E X 1 4 ' - 9 1 /8 " 9 ' - 4 " 3 ' - 6 " 1 5 " 1 8 " 52 1/8" 52 1/8" 52 1/8" 52 1/8" SCREEN PATIO UNDERDECKING GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE PARALLEL CHORD ROOF TRUSSES PER MFG. SPEC. 2X12 JOISTS @ 16" O.C. CONTINOUS BEAM PER MFG SPEC 8 x 8 C O L U M N W R A P P E D 8 x 8 C O L U M N W R A P P E D G U A R D R A I L 3 6 " 6 6 1 /8 " SCREEN PORCH COMPOSITE DECKING PINE T&G CLG E .H . 1 5 3 /1 6 " 24" 24" D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 4 A M 06 C r o s s S e c t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 1/4" = 1'- 0" 1 Cross Section - Dining/Screen Porch 1/4" = 1'- 0" 3 Cross Section - Foyer/Great Room 1/4" = 1'- 0" 2 Detail - Screen Porch Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" Garage T.O.F. - 1' - 8 1/4" 9 ' - 1 1 /8 " 5 ' - 6 1 1 /1 6 " E .H . 8 1 /1 6 " T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " E .H . 5 1 9 /1 6 " 6 6 1 1 /1 6 " 9 1 /4 " 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GARAGE GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL GIRDER TRUSS FLUSH PER MFG. SPEC. 3 ' - 6 " BEDROOM #3 3' - 0" 7' - 8 3/4" 7' - 8 3/4" 3' - 0" 24" E .H . 2 5 5 /1 6 " 16" 12" BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 07 4 First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" Garage T.O.F. - 1' - 8 1/4" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. CONCRETE STEPS 3 ' - 6 " 9 ' - 0 " 3 ' - 6 " SCREEN PATIO UNDERDECKING GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE PARALLEL CHORD ROOF TRUSSES PER MFG. SPEC. 2X12 JOISTS @ 16" O.C. CONT. BEAM PER MFG SPEC SCREEN PORCH COMPOSITE DECKING PINE T&G CLG OUTDOOR GRILL 8 ' - 1 0 " 1 0 ' - 1 1 /8 " 9 ' - 1 1 /8 " E .H . 6 7 /8 " 9 ' - 4 " 9 ' - 3 " T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " 2 1 " 2 0 1 /4 " 8 ' - 4 1 /8 " 2 1 " 3 3 /4 " 18' - 0" 14' - 0" 13' - 0" 21' - 0" 6" 6" 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. 6 1/2" 12" 14" 12" 7" 12" GUEST BEDROOM W.I.C. MUD ROOM GARAGE BEDROOM #3 BATH GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL T .O .F . T O W D W R .O . 7 ' - 6 " SLOPED CLG. 08 4 09 2 72" 72" 72" 1 2 " DROPPED CLG. HVAC 24" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. GREAT ROOM FAMILY ROOM ROOF TRUSSES PER MFG. SPEC. 8 ' - 1 0 " 1 0 ' - 1 1 /8 " E .H . 2 5 1 /1 6 " 4' - 0" 14' - 0" 3 ' - 6 " 24" 5 1/2" 24" 1 4 1 3 /1 6 " 14 5/16" 20" RADIUS 2 x 6 R A F T E R T A I L2x4 L O O K O U T 1/2" BENDABLE PLYWOOD 1 3 5 .0 0 ° 3 8 1 1 /1 6 " 2x4 LOOK OUT 2x6 6" R O O F T R U S S E S P E R M F G S P E C 5 9 .0 0 °EAVE DRIP COMPOSITE FASCIA D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 6 A M 07 C r o s s S e c t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 1/4" = 1'- 0" 3 Cross Section - Garage/Bedroom#3 1/4" = 1'- 0" 2 Cross Section - Garage/Screen Porch 1/4" = 1'- 0" 1 Detail - Great Room E.H. 1" = 1'- 0" 4 Detail - Radius Garage Overhang 1 1/2" = 1'- 0" 5 Detail - Front Gabel Fascia First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" Garage T.O.F. - 1' - 8 1/4" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. TYPICAL STAIRCASE CONSTRUCTION: 6'- 10" MINIMUM HEADROOM (3) 11 - 7/8" STAIR STRINGER w/1 - 1/8" x 11 - 1/4" PARTICLE BOARD TREADS PROVIDE 34" - 36" HGT HANDRAILS & GUARDS RAILS PER CODE MAIN STAIRCASE LANDING CONSTRUCTION: 2 - 4 x 8 RECTANGLE STEEL TUBE SUPPORTS 3/4" PLYWOOD BACKING 2x8 JOISTS @ 16" O.C. 3/4" PLYWOOD 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. 9 6 " 3/4" SUBFLOOR 2x4 LADDER TRUSS @ 19.2" O.C. 12" 2 4 " ROOF TRUSSES PER MFG. SPEC. GARAGE GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL KIDZ LOFT BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 3 ' - 6 " 9 ' - 0 " 9 ' - 0 " 2 2 ' - 1 1 1 /4 " 1 0 ' - 8 1 /4 " 4 ' - 1 0 " 6 ' - 3 7 /8 " 4 ' - 3 3 /8 " 6 ' - 1 3 /8 " 6 ' - 0 1 5 /1 6 " 6 ' - 0 1 5 /1 6 " 1 7 R I S E R S 1 0 ' - 4 3 /4 " 2 0 R I S E R S 1 2 ' - 1 7 /8 " 7 5 /1 6 " 11" 11" 7 5 /1 6 " 13' - 3" 9 6 " 47' - 0" 23' - 0" 6" T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " 9 ' - 1 1 /8 " 8 ' - 1 0 " 1 0 ' - 1 1 /8 " 9 ' - 0 1 1 3 /2 5 6 " 16" 12" 5" 12" 2 0 1 /4 " 8 ' - 4 1 /8 " 2 1 3 /8 " 2 1 3 /4 " 3 3 /4 " 11" 7 " HALLWAY STAIRS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL ARCADE GAMES MECHANICAL ROOM PANTRY BATH ROOF TRUSSES PER MFG. SPEC. LOWER STAIRCASE LANDING CONSTRUCTION: 2 - 2x8 HEADER 3/4" PLYWOOD BACKING 2x8 JOISTS @ 16" O.C. 3/4" PLYWOOD 24" 66 1/2" 24" 8 " 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP STAIRCASE LANDING SUPPORTS First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" Garage Clg. 8' - 4 1/8" Garage T.O.F. - 1' - 8 1/4" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL 9 ' - 0 " 9 ' - 0 " 2' - 0" 52' - 0" 16' - 0" 6" 6" 6" 16" 12" 7" 12" T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " E .H . 2 9 9 /1 6 " 8 ' - 4 1 /8 " 1 ' - 8 1 /4 " 1 ' - 9 " 8 ' - 1 0 " 1 0 ' - 1 1 /8 " 9 ' - 1 1 /8 " GUEST BEDROOM BATH GAME ROOM FAMILY ROOM GREAT ROOM KITCHEN BUTLER PANTRY MUD ROOM GARAGE BEDROOM #4 W.I.C. OWNER'S SUITE 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL 1 1 ' - 2 3 /4 " VAULTED CLG APEX RECESSED CLG. 3' - 9" 27' - 6" 3' - 9" 8 " 58" 10" 58" 10" 58" 10" 58" 10" 58" 8" WOOD B'M R O O F T R U S S E S P E R M F G . S P E C . 30" ROOF TRUSSES PER MFG. SPEC. 8 ' - 1 0 " 1 0 ' - 1 1 /8 " 9 ' - 1 1 /8 " 2 0 1 /4 " 8 ' - 4 1 /8 " 2 1 " 2 1 " T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " 3 3 /4 " 2 4 3 /4 " 1 8 3 /4 " 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. GARAGE GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). E .H . 1 1 1 5 /1 6 " ROOF TRUSSES PER MFG. SPEC. 4 1/4" 12" 10' - 0" 6" 24" 2 4 " W.I.C. BATH 9 ' - 0 " 3/4" SUBFLOOR 2x4 LADDER TRUSS @ 19.2" O.C. 24" 24" 2 x 4 R A F T E R T A I L S COMPOSITE VENTED SOFFIT 1x6 COMPOSITE FASCIA E A V E D R I P 2x4 LOOK - OUT D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 7 A M 08 C r o s s S e c t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 1/4" = 1'- 0" 1 Cross Section - Garage/Staircase 1/4" = 1'- 0" 3 Cross Section - Great Room/Garage 1/4" = 1'- 0" 2 Detail - W.I.C. E.H./Raised 2nd Floor 1" = 1'- 0" 4 Detail - Typical Overhang Construction First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" Garage T.O.F. - 1' - 8 1/4" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. CANTILEVER INSULATION: SPRAY FOAM INSULATION R - 30 MIN. 10' - 0" 12' - 0" 24" 2 4 " 7 1 /4 " 1 0 ' - 1 1 /8 " 1 0 ' - 8 3 /8 " 9 ' - 0 " 3 ' - 6 " F L R D I F 2 1 " 1 ' - 8 1 /4 " 8 ' - 4 1 /8 " 1 ' - 9 "3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GARAGE GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL GIRDER TRUSS FLUSH PER MFG. SPEC. BEDROOM #3 9 ' - 1 1 /8 " 5 ' - 6 1 1 /1 6 " ROOF TRUSSES PER MFG. SPEC. 9 ' - 1 1 /8 " 8 ' - 6 3 /8 " E .H . 8 1 /1 6 " 8 ' - 1 0 " 1 0 ' - 1 1 /8 " E .H . 1 3 1 /8 "E .H . 4 4 1 5 /1 6 " E .H . 8 1 /1 6 " 3 3 /4 " BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 12' - 0" 11' - 0" 13' - 0" 10' - 3 1/4" 10' - 8 3/4" 13' - 0" 16" 12" 16" 12" 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. BEDROOM #2 OFFICE EXERCISE ROOM FRONT PORCH 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP BEAM FLUSH PER MFG. SPEC. BEAM FLUSH PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " 7' - 8 3/4" 7' - 8 3/4" 7' - 0" 7' - 0" 9 1 /4 " 9 1/4" ROOF TRUSSES PER MFG. SPEC. 6" 1 8 " First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" First Floor Clg. 10' - 1 1/8" Roof Peak 30' - 10" 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 10' - 0" 4' - 0" 14' - 0" 12" 14" 12" 6 1/2" 12" E .H . V A R I E S 2 4 " 9 ' - 1 1 /8 " E .H . 6 7 /8 " 1 0 ' - 1 1 /8 " 8 ' - 1 0 " 4 ' - 3 3 /8 " 6 ' - 1 3 /8 " 6 ' - 0 1 5 /1 6 " 6 ' - 0 1 5 /1 6 " 1 0 ' - 4 3 /4 " 1 2 ' - 1 7 /8 " 1 1 ' - 1 7 /8 " 9 ' - 0 " 2 2 ' - 1 1 1 /4 " 1 3 1 /8 " 2 0 1 /4 " 2 4 " 24" 16' - 0" 1 0 ' - 8 3 /8 " 7 1 /4 " 1 0 ' - 1 1 /8 " LINE OF MAIN LEVEL 2x4 PARAPET WALLS VARIES IN HEIGHT. HEIGHT WILL BE DETERMINED BY 1/4":12" SLOPE OF MAIN ROOF UNLESS NOTED 1/4" SLOPED FLAT ROOF: ENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 3 ' - 6 " 9 ' - 0 " GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. V A U L T E D C L G A P E X 1 1 ' - 2 3 /4 " 3" 12" STAIRS OWNER'S SUITE FRONT PORCH GREAT ROOM FAMILY ROOM TYPICAL STAIRCASE LANDING CONSTRUCTION: 2 - 2x8 HEADER 3/4" PLYWOOD BACKING 2x8 JOISTS @ 16" O.C. 3/4" PLYWOOD BEAM FLUSH PER MFG. SPEC. 24" 24" First Floor 0' - 0" Second Floor 12' - 1 7/8" Roof 21' - 3" Basement - 10' - 4 3/4" T.O. Footing - 10' - 8 1/4" Top of Foundation - 1' - 8 1/4" Stepped 2nd Floor 10' - 4 7/8" Garage Clg. 8' - 4 1/8" Garage Clg. 8' - 4 1/8" Stepped 2nd Clg. 19' - 6" Garage T.O.F. - 1' - 8 1/4" 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ROOF TRUSSES PER MFG. SPEC. GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE GARAGE WALLS: INSULATE WALLS 5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLS BATHROOM OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED. HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R - 49). 3 ' - 6 " T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " E .H . 3 4 1 1 /1 6 " 7 ' - 2 7 /1 6 " E .H . 7 1 /2 " 9 ' - 1 1 /8 " E .H . 1 3 1 /8 " T .O .F . T O W D W R .O . 7 ' - 6 " E .H . 8 7 /1 6 " T .O .F . T O T O P P L A T E 1 0 ' - 0 3 /8 " 8' - 0" 15' - 0" 10' - 11 1/2" 8' - 0 1/2" 9 1 / 4 " ROOF TRUSSES PER MFG. SPEC. ROOF TRUSSES PER MFG. SPEC. 7" 12" 7" 12" 1 2 ' - 2 1 /2 " 10" STORAGE ROOM KIDZ LOFT GARAGE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL BEAM FLUSH PER MFG. SPEC. BEAM FLUSH PER MFG. SPEC. S U B F L O O R T O W D W R .O . 7 5 " 38 13/16" 24" 24" 24" 2X8 JOISTS PITCHED @ 16" O.C. w/SOLID BLOCKING BETWEEN EACH JOIST 24" PROVIDE SOLID BLOCKING FOR CANOPY HANGERS 1/4" SLOPED CANOPY ROOF: 2x8 JOISTS SLOPED @ 1/4" / 12" @ 16" O.C. (PER MFG. SPEC.) SELF - BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 12" - 18" ABOVE ABUDDING WALLS 3/4" PLYWOOD SHEATHING w/STEEL CLIPS COMPOSITE FASCIA CANT STRIP 9 1 /4 " D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :0 9 A M 09 C r o s s S e c t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 1/4" = 1'- 0" 1 Cross Section - Office/Garage 1/4" = 1'- 0" 4 Cross Section - Front Porch/Great Room 1/4" = 1'- 0" 3 Cross Section - Garage/Kidz Loft 1" = 1'- 0" 2 Detail - Typical Canopy Construction UP UP DN DN DN DN DN 1645 SF LOWER LEVEL 362 SF SCREEN PATIO 98 SF MECH. 1825 SF MAIN LEVEL 362 SF SCREEN PORCH 1160 SF GARAGE 446 SF FRONT PORCH 2107 SF UPPER LEVEL 287 SF KIDZ LOFT 129 SF STORAGE 134 SF STAIRCASE 6 1/2" 12" E .H . 6 7 /8 " 9 ' - 1 1 /8 " 2 4 3 /4 " 1 0 ' - 1 1 /8 " 1 8 3 /4 " 8 ' - 1 0 " L O W E R L E V E L W I N D O W H E A D E R H E I G H T 8 ' - 0 " G R E A T R O O M R E A R E L E V A T I O N W I N D O W H E A D E R H E I G H T 9 ' - 6 " U P P E R L E V E L W I N D O W H E A D E R H E I G H T 8 ' - 0 " 3 ' - 6 " ROOF, CEILING & EAVE CONSTRUCTION: WALL CONSTRUCTION: FOUNDATION WALL & BASEMENT SLAB CONSTRUCTION: MAIN LEVEL CONSTRUCTION: UPPER LEVEL CONSTRUCTION: ARCHITECTURAL GRADE ASPHALT SHINGLES #15FELT & ICE & WATER SHIELD (6'- 0") 1/2" OSB SHEATHING w/STEEL CLIPS TRUSSES @ 24" O.C. (PER MFG. SPEC.) BAFFLES w/1" AIR SPACE 2X4 LOOKOUTS 2X6 SUB FASCIA w/ 6" COMPOSITE FASCIA COMPOSITE VENTED SOFFITS COMPOSITE FRIEZE BOARDS R - 50 BLOWN INSULATION POLY VAPOR BARRIER 5/8" GYP. BRD. CEILING 3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED 24" FLOOR TRUSSES @ 19.2" O.C. (FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS) 5/8" GYP. BRD. ON CEILING SPRAY INSULATE RIMS (R - 21) SIDING PER ELEVATION HOUSE WRAP (WRAP WINDOWS PER MFG. SPEC.) 1/2" OSB SHEATHING 2X6 STUDS @16" O.C. DBL. TOP PLATE R - 21 WALL INSULATION 4 MIL POLY VAPOR BARRIER 1/2" GYP. BRD. 2X6 SOLE PLATE ALL DETAILS TO CONFORM W/ ENERGY CODE 3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED 18" FLOOR TRUSSES @ 19.2" O.C. (FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS) FLASHING UNDER SILLS & STOOPS TREATED 2X6 SILL PLATE w/ SEALER 1/2" ANCHOR BOLTS @ 6' O.C. & 1' FROM CORNERS 5/8" GYP. BRD. ON CEILING SPRAY INSULATE RIMS (R - 21) WATERPROOFING EXTERIOR THERMAL WALL: 2" RIGID INSULATION (R - 10) APPLIED TO EXTERIOR, PROVIDE FLASHING TO COVER EXPOSED INSULATION POURED CONC. WALL PER PLAN REINFORCE WALLS PER CODE AND ENGINEER'S SPECIFICATIONS 20" X 8" CONTINUOUS CONC. FOOTING UNLESS OTHERWISE NOTED 4" CONC. SLAB VAPOR/MOISTURE BARRIER PER IRC SECTION 506 EXTENDING UP THE WALL AND SEALED TO FOUNDATION WALL 4" SAND/AGGREGATE FILL INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TO SUMP BASKET INTERIOR THERMAL WALL: 1" RIGID INSULATION (R - 5) 2x4 STUDS @ 16" O.C. 2x4 TRD. PLATE 1/2" GYP BD. 5 1 /2 " 2' - 0" M A I N L E V E L W I N D O W H E A D E R H E I G H T 9 ' - 0 " 24" D R A W N B Y D E S C R I P T I O N P R O J E C T # P R O J E C T I S S U E R E - I S S U E B U I L D E R 1 8 4 7 6 K E N R I C K A V E S U I T E 2 0 2 L A K E V I L L E , M N 5 5 0 4 4 T E L : 9 5 2 .4 2 8 .8 2 0 0 E M : D a v e @ D a v i d C h a r l e z D e s i g n s .c o m D A V I D C H A R L E Z D E S I G N S a Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licens ed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by th e manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclo sed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2018. Do not replicate with out permission (952)428 - 8200. David Charlez Design retains rights to all plans and detail shown. 1 1 /2 0 /2 0 1 8 1 0 :5 5 :1 0 A M 10 S q u a r e F o o t a g e C a l c u l a t i o n s S D C - S c o l e s R e s i d e n c e - C D - R E V 2 - L M C S c o l e s R e s i d e n c e S D C u s t o m H o m e s 7 5 0 M a i n S t r e e t S u i t e #2 2 3 M e n d o t a H e i g h t s , M N 5 5 1 1 8 9 .2 8 .2 0 1 8 S M M 1 9 4 7 5 I t e r i A v e . L a k e v i l l e , M N 5 5 0 4 4 LOWER LEVEL: SQUARE FOOTAGE CALCULATIONS 1645 SQ. FT. LOWER LEVEL 98 SQ. FT. MECHANICAL ROOM 362 SQ. FT. SCREEN PATIO 1825 SQ. FT. MAIN LEVEL 1160 SQ. FT. GARAGE 362 SQ. FT. SCREEN PORCH 446 SQ. FT. FRONT PORCH 2107 SQ. FT. UPPER LEVEL 287 SQ. FT. KIDZ LOFT 129 SQ. FT. STORAGE 134 SQ. FT. STAIRCASE 5864 SQ. FT. FINISHED TOTAL (DOES NOT INCLUDED U.L. STAIRCASE) GENERAL NOTES 1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C. 2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS OTHERWISE NOTED) 3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING 4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR. 5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD 6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND 50% AT SOFFIT - MIN 7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILER UNLESS OTHERWISE NOTED. UNDERCUT MIN 1" 8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER. 9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF A DOORWAY SHALL BE TEMPERED GLASS 10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR EQUIVALENT 11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR 12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES 13. 1/2" AIR SPACE ON EACH SIDE OF MICRO - LAM BEAM & MIN 3" BEARING ON CONCRETE 14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE TO PASS THROUGH 15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE 16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY 17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS 18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE 19. PROVIDE DRAFT STOPS PER UBC 708.3 20. FIRE BLOCK ALL CHASES AT EACH FLOOR - CEILING ASSEMBLY OR AT 10' MAX INTERVALS 21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE 22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD 23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS 24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED MATERIALS 25. BLOCK PATIO DOORS WITHOUT A DECK 26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC 27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES 28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE ROOMS 29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE STAIRS 30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN REQUIRED (IMC703) 31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED 32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE 62 - 2001 6.1) 33. DRYER VENT TO THE EXTERIOR - INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER OPENINGS: (IMC504.4, 401.52 AND 604.1) 34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS. CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE VAPOR BARRIER (R307) 35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE. ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL 36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE REQUIRED AT MIN 4" O.C. 37. 4 - MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING. FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED 38. WIND - WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING INSULATION DAM @ CEILING CHANGES 39. WEATHER - RESISTIVE BARRIER - i.e. BUILDING WRAP TABLE R703.4 40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO AT LEAST R - 3 41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE WEATHERED - STRIPPED AND INSULATED. 42. NEW WOOD - BURNING FIREPLACES WILL HAVE TIGHT - FITTING FLUE DAMPERS AND OUTDOOR COMBUSTION AIR. 43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6' ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4", WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL DEVICES. 44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH SLEEPING AREA OR BEDROOM. 45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi. 46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES. EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10". 47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL LOADS. 48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER - RESISTIVE BARRIER MUST LAP OVER THE ATTACHMENT FLANGE. 49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS 1/8" = 1'- 0" 1 Basement 1/8" = 1'- 0" 2 First Floor 1/8" = 1'- 0" 3 Second Floor 1/2" = 1'- 0" 4 Detail - Typical Wall Section MAIN LEVEL: UPPER LEVEL: FINISHED TOTAL: DI M E N S I O N S O N T H E T R U S S L A Y O U T AR E F R O M O U T S I D E O F F R A M I N G . LE F T E N D O F T H E T R U S S E S A R E DE N O T E D O N T H E L A Y O U T W I T H A LI T T L E T R I A N G L E . DO N O T C U T T R U S S E S . IF Y O U H A V E A N Y Q U E S T I O N S O R CO N C E R N S , P L E A S E C A L L Da l l a s Y u r e k 6 5 1 - 2 8 7 - 1 9 4 8 OR E M A I L : Dy u r e k @ V I L L A U M E . C O M D1 D1 D2 D1 D3 D3 D3 D3 D3 D3 G 1 C2 C1 C1 C1 C1 C1 C1C6CT1C10 C8 C11 C9 C7 C7 C5 C4 C4 C4 C3 B7 B6 B5 B5 B5 A5 A4 A4 A4 A7 A6 A3 A2 A2 A2 B4 B3 B3 B3 B3 A2 A1 A1 A1 B1 B1 B1 B1 B1 B1 B2 C 4 P 1 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 LUS26 LUS26 LUS26 LUS26 LUS26 LU S 2 4 L U S 2 4 LU S 2 4 L U S 2 4 LU S 2 4 L U S 2 4 LU S 2 4 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 L U S 2 6 HJC26 LUS26 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 Z ZZ T3 H 2 H 1 H 1 H 1 H 1 H 1 H 1 H 1 N 1 K2 K1 K1 K1 K3 T1 0 K 1 1 K 1 0 K 9 K 8 K 7 K 6 K 5 K1 2 K 4 K1 2 T4 M1 M1 M1 M1 M1 M1 T8 T7 T7 T7 T9 N 2 N 3 N 4 N 5 N 6 N 7 N 7 N 7 T6 T5 T2 T1 T1 T1 T1 N 8 N 9 N 9 N 9 N 9 N 9 N 9 N 9 N 9 N 1 0 R2 R1 R1 R1 R1 R1 R1 R1 U1 S 4 S 3 S 2 S 2 S 1 R 5 R 5 R 4 R 3 V1 V2 V3 V4 V5 V6 V1 1 L V1 2 L V1 3 L V1 4 L V7 R V8 R V9 R V1 0 R LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 8 HH U S 2 1 0 - 2 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 H U S 2 6 H U S 2 1 0 H U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 H U S 2 6 H U S 2 6 H U S 2 6 L U S 2 6 H U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 H U S 2 6 H U S 2 6 H U S 2 6 H U S 2 6 H U S 2 6 Customer: Dakota County LumberJob Number: 307047-A Home Owner: SD CUSTOM / SCOLESJob Name: Roof Site Address: 19475 ITERI AVE Sales Rep: John Hummel City, ST, ZIP: LAKEVILLE MN Designer: Dallas Yurek2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 3/11/2019 Version: 8.2.4.272 18 " D E E P T R U S S E S 19 . 2 " O . C . B A S E S P A C I N G . DI M E N S I O N S O N T R U S S L A Y O U T A R E FR O M O U T S I D E O F F R A M I N G . LE F T E N D O F T R U S S E S A R E D E N O T E D ON T H E L A Y O U T W I T H A L I T T L E TR I A N G L E . L E F T E N D O F T R U S S HA S A L S O B E E N P A I N T E D . PL U M B I N G L O C A T I O N S A R E E S T I M A T E D . CO N T R A C T O R T O V E R I F Y P L U M B I N G LO C A T I O N S . D O N O T C U T T R U S S E S . IF Y O U H A V E A N Y Q U E S T I O N S O R CO N C E R N S , P L E A S E C A L L Da l l a s Y u r e k 6 5 1 - 2 8 7 - 1 9 4 8 OR E M A I L : D y u r e k @ V I L L A U M E . C O M 3p l y D r o p p e d B e a m B O 3p l y F l u s h B e a m B O 2 p l y F l u s h B e a m B O 2 p l y F l u s h B E a m B O 2p l y F l u s h B e a m B O 2p l y F l u s h B e a m B O 2p l y F l u s h B e a m B O F 3 F 2 F 2 F 1 F 1 F 1 F 1 F 1 F 1 F 5 F 5 F 5 F 4 F 6 F 7 F 7 F 7 F 7 F 7 F 7 F 7 F 7 F 7 F 8 F 8 F 9 F 9 F 8 F 1 1 F 1 1 F 1 1 F11 F10 F10 F12 F 1 7 F 1 3 F 1 8 F 1 8 F 1 8 F 1 4 F 1 4 F 1 5 F 1 5 F 1 5 F 1 5 F 1 5 F 1 5 F 1 4 F 1 4 F 1 6 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1 - 0 7 - 0 3 1-07-03 1-07-03 1-02-13 1 - 0 7 - 1 3 1 - 0 6 - 0 9 6 - 0 0 - 0 0 6 - 0 0 - 0 0 2 8 - 0 0 - 0 0 1 2 - 0 0 - 0 0 5 2 - 0 0 - 0 0 14-06-00 7-05-08 18-00-08 12-00-00 52-00-00 12 - 0 0 - 0 0 1 0 - 0 0 - 0 0 1 4 - 0 0 - 0 0 8 - 0 6 - 0 8 9 - 0 5 - 0 8 54 - 0 0 - 0 0 20 - 0 0 - 0 0 16 - 0 0 - 0 0 18 - 0 0 - 0 0 54 - 0 0 - 0 0 Customer: Dakota County LumberJob Number: 307047-C Home Owner: SD CUSTOM / SCOLESJob Name: 2nd Floor Site Address: 19475 ITERI AVE Sales Rep: John Hummel City, ST, ZIP: LAKEVILLE MN Designer: Dallas Yurek2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 3/4/2019 Version: 8.2.4.272 Double plate on floor truss end verts 1" GapHandframe down for box vault as req.Beam raised 8" into floor container, partially dropped fur down as req.Flush Beam BO Garage/House Wall DI M E N S I O N S O N T H E T R U S S L A Y O U T AR E F R O M O U T S I D E O F F R A M I N G . LE F T E N D O F T H E T R U S S E S A R E DE N O T E D O N T H E L A Y O U T W I T H A LI T T L E T R I A N G L E . DO N O T C U T T R U S S E S . IF Y O U H A V E A N Y Q U E S T I O N S O R CO N C E R N S , P L E A S E C A L L Da l l a s Y u r e k 6 5 1 - 2 8 7 - 1 9 4 8 OR E M A I L : Dy u r e k @ V I L L A U M E . C O M F F 1 7 F F 1 6 F F 2 2 F F 2 2 F F 2 2 F F 2 2 F F 2 2 F F 2 2 F F 2 3 F F 2 3 F F 2 3 F F 2 4 F F 1 9 F F 2 5 F F 2 6 F F 2 6 F F 2 6 F F 2 6 F F 2 6 F F 2 6 F F 1 5 F F 1 8 F F 2 8 F F 2 8 F F 2 8 F F 2 8 F F 2 8 F F 2 8 F F 2 8 F F 2 8 F F 1 8 F F 1 5 F F 1 5 F F 1 2 F F 1 2 F F 1 2 F F 1 2 F F 1 3 F F 1 3 F F 1 3 F F 1 3 F F 1 3 F F 1 3 F F 1 2 F F 1 9 F F 1 4 F F 1 1 F F 1 1 F F 1 0 F F 1 0 F F 1 0 F F 1 0 F F 9 F F 9 F F 9 F F 9 F F 2 1 F F 2 1 F F 2 1 F F 2 1 F F 2 1 F F 2 7 F F 2 7 F F 2 7 F F 2 7 F F 2 F F 2 F F 2 F F 2 F F 2 F F 2 F F 2 FF2 FF2 FF2 FF3 F F 1 F F 1 F F 1 F F 1 F F 1 F F 1 F F 4 F F 4 F F 4 F F 6 F F 2 0 F F 8 FF 3 2 FF 3 2 FF 3 2 FF 3 2 FF 3 2 FF 3 2 FF 3 2 FF 3 0 FF 3 0 FF 3 1 FF 3 1 FF 2 9 FF 2 9 FF 3 1 D1 D1 D2 D1 D3 D3 D3 D3 D3 D3 G 1 C2 C1 C1 C 1 C 1 C 1 C 1 C 6 CT1 C10 C8 C11 C9 C7 C7 C 5 C 4 C 4 C 4 C 3 B7 B6 B5 B5 B5 A5 A4 A4 A4 A7 A6 A3 A2 A2 A2 B4 B3 B3 B3 B3 A2 A1 A1 A1 B1 B1 B1 B1 B1 B1 B2 C 4 X 1 P 1 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 HU S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 L U S 2 6 LU S 2 4 L U S 2 4 LU S 2 4 L U S 2 4 LU S 2 4 LU S 2 4 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 LU S 2 6 L U S 2 6 HJ C 2 6 L U S 2 6 L U S 2 4 L U S 2 4 LUS24 LUS24 L U S 2 4 L U S 2 4 1 3 - 0 6 - 0 0 27 - 0 6 - 0 0 7 - 0 5 - 0 8 11 - 0 1 - 0 0 8-04-02 10-01-0210-01-028-00 1-04-00 2-00-00 2-00-00 10-01-02 Customer: Dakota County LumberJob Number: 307047-C Home Owner: SD CUSTOM / SCOLESJob Name: 2nd Floor Site Address: 19475 ITERI AVE Sales Rep: John Hummel City, ST, ZIP: LAKEVILLE MN Designer: Dallas Yurek2926 Lone Oak Circle, St. Paul, MN 55121 Ph: 651-454-3610 Fax: 651-454-4765 Date: 3/11/2019 Version: 8.2.4.272 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-08 16:45:58 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 ...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor: 19475 Iteri Ave, Lakeville, mn Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F) Semi-tightConstruction quality7572Inside db (°F) 0Fireplaces1387Design TD (°F) M-Daily range 5030Inside humidity (%) 3134Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model EL296UH110XE60C-*Cond XC14-060-230-** AHRI ref 5625720 Coil C33-50/60C+EL296UH110XE60C*+TDR+TXV AHRI ref 5697852 Efficiency 96 AFUE Efficiency 11.7 EER, 14 SEER Heating input Btuh110000 Sensible cooling Btuh39550 Heating output Btuh106000 Latent cooling Btuh16950 Temperature rise °F53 Total cooling Btuh56500 Actual air flow cfm1883 Actual air flow cfm1883 Air flow factor cfm/Btuh0.019 Air flow factor cfm/Btuh0.052 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.83 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) below grade 1295 7993 437 156 23 main floor 1846 35974 15462 700 806 second floor 2667 36652 14587 713 760 walk out 551 16149 5652 314 295 Entire House d 6358 96767 36138 1883 1883 Other equip loads 5960 2946 Equip. @ 0.93 RSM 36309 Latent cooling 7996 TOTALS 6358 102728 44305 1883 1883 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-08 16:45:58 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 ...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Loads for Multiple Orientations Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor: 19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude: Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) )M(18-Daily range (°F) 72-Wet bulb (°F) 7.515.0Wind speed (mph) Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh)33137 37423 37170 37173 31997 35888 36309 36780 Latent Load (Btuh)7996 7996 7996 7996 7996 7996 7996 7996 Total Load (Btuh)41133 45419 45166 45169 39993 43884 44305 44775 Heating AVF (cfm)1883 1883 1883 1883 1883 1883 1883 1883 Cooling AVF (cfm)1883 1883 1883 1883 1883 1883 1883 1883 Building Orientation Cooling Load To t a l C o o l i n g L o a d ( B t u h ) Direction Front Door faces 0 10000 20000 30000 40000 50000 N NE E SE S SW W NW Front Door faces WestCurrent Orientation: Front Door faces NortheastHighest Cooling Load: Bold/italic values have been manually overridden 2018-Nov-08 16:46:00 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Building Analysis Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor:7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation:5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F)SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 23.5241564.4Walls 39.04009227.8Glazing 0.663930.4Doors 4.747841.7Ceilings 6.365172.42.4Floors 20.0205793.8Infiltration 00Ducts00Piping00Humidification5.85960Ventilation0Adjustments100.0102728Total Cooling Walls Glazing Other Ceilings Infiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 8.734160.6Walls 63.12466517.1Glazing 0.51878.9Doors 6.926921.0Ceilings 0.52120.1Floors 4.115870.3Infiltration 00Ducts7.52946Ventilation8.63380Internal gains 00Blower0Adjustments100.039084Total Latent Cooling Load = 7996 BtuhOverall U-value = 0.072 Btuh/ft²-°F Data entries checked. 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Component Constructions Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15 ins, 10" thk 380.1113233.9515.00.042335n 380.1113233.9515.00.042335s 620.1121633.9515.00.042548w 1370.1148093.9515.00.0421218all IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 8100.8243114.3520.00.050991n 10020.8253324.3520.00.0501226e 6240.8233234.3520.00.050764s 5840.8231104.3520.00.050715w 30210.82160764.3520.00.0503696all Partitions 12F-0sw: Frm wall, 1/2" wood shth, r-21 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2580.4532715.6521.00.065579 Windowsmarvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 26437.71954027.800.320343n 1022421.91302627.800.320468e 108513.0233227.800.32084s 700921.9893027.800.320321w 2096117.33382827.800.3201215all 10A-m: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 64215.3116927.800.32042e 157321.9200427.800.32072e 116613.0250627.800.32090s 32115.358527.800.32021w 370316.5626427.800.320225all Doors11N0: Door, mtl eps core type 1878.9163930.48.70.35021n Ceilings16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 26920.9847841.7450.00.0202750 Floors 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 2...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 5/8" gypsum board int fnsh 350.372332.4830.00.03494 19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul 1780.2211981.4830.00.049810 21A-32t: Bg floor, heavy dry or light damp soil, 8' depth 00.0201295 0022531.74 22B-10tpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins 00283430.910.00.35592 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 3...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Component Constructions Date:below grade By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15 ins, 10" thk 380.1113233.9515.00.042335n 380.1113233.9515.00.042335s 620.1121633.9515.00.042548w 1370.1148093.9515.00.0421218all Partitions(none) Windows (none) Doors (none) Ceilings(none) Floors21A-32t: Bg floor, heavy dry or light damp soil, 8' depth 00.0201295 0022531.74 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 4...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Component Constructions Date:main floor By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2490.8213274.3520.00.050305n 3040.8216204.3520.00.050372e 700.823744.3520.00.05086s 1930.8210244.3520.00.050236w 8170.8243454.3520.00.050999all Partitions 12F-0sw: Frm wall, 1/2" wood shth, r-21 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2580.4532715.6521.00.065579 Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 20587.71743127.800.320267n 502421.9640027.800.320230e 310821.9396027.800.320142w 1019015.91779227.800.320639all 1A-c1omd: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 116613.0250627.800.32090s 32115.358527.800.32021w 148813.4309027.800.320111all Doors 11N0: Door, mtl eps core type 1878.9163930.48.70.35021n Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 810.981441.7450.00.02083 Floors(none) 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 5...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Component Constructions Date:second floor By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 4200.8222344.3520.00.050514n 4180.8222234.3520.00.050511e 4270.8222734.3520.00.050523s 3920.8220864.3520.00.050479w 16570.8288164.3520.00.0502027all Partitions (none) Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 4867.71175427.800.32063n 321221.9409227.800.320147e 70013.0150327.800.32054s 390121.9497027.800.320179w 829918.81232027.800.320443all Doors(none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 26110.9846401.7450.00.0202667 Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 5/8" gypsum board int fnsh 350.372332.4830.00.03494 19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul 1780.2211981.4830.00.049810 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 6...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Component Constructions Date:walk out By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F) SimplifiedMethod)M(18-Daily range (°F) Semi-tightConstruction quality72-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1410.827494.3520.00.050172n 2800.8214904.3520.00.050343e 1270.826754.3520.00.050155s 5480.8229154.3520.00.050670all Partitions(none) Windows marvin fiberglass integrety: low e fiber glass marvin; NFRC rated (SHGC=0.19); 6.67 ft head ht 987.7135527.800.32013n 198821.9253327.800.32091e 38613.082827.800.32030s 247218.5371727.800.320134all 10A-m: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk; NFRC rated (SHGC=0.19); 6.67 ft head ht 64215.3116927.800.32042e 157321.9200427.800.32072e 221619.4317427.800.320114all Doors(none) Ceilings (none) Floors 22B-10tpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins 00283430.910.00.35592 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-08 16:46:00Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:Project Summary Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor:19475 Iteri Ave, Lakeville, mn Notes: Design Information Minneapolis-St Paul Int'l Arp, MN, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-15 Outside db °F88Inside db °F72 Inside db °F75Design TD °F87 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh96767 Structure Btuh36138DuctsBtuh0DuctsBtuh0Central vent (SER=70% 214 cfm)Btuh5960 Central vent (SER=0% 214 cfm)2946 BtuhHeat recovery Heat recoveryHumidificationBtuh0Blower Btuh0PipingBtuh0Equipment load Btuh102728 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh36309 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Semi-tight0Fireplaces Structure Btuh3579DuctsBtuh0Central vent (214 cfm)Btuh4417CoolingHeatingHeat recovery63586358Area (ft²)Equipment latent load Btuh79965319853198Volume (ft³)Air changes/hour 0.130.25 Equipment Total Load (Sen+Lat)Btuh44305Equiv. AVF (cfm)115222 Req. total capacity at 0.70 SHR ton4.3 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make LennoxTradeLENNOXTradeLENNOXModelEL296UH110XE60C-*Cond XC14-060-230-**AHRI ref 5625720 Coil C33-50/60C+EL296UH110XE60C*+TDR+TXVAHRI ref 5697852Efficiency96 AFUE Efficiency 11.7 EER, 14 SEERHeating input Btuh110000 Sensible cooling Btuh39550Heating output Btuh106000 Latent cooling Btuh16950Temperature rise °F53 Total cooling Btuh56500Actual air flow cfm1883 Actual air flow cfm1883Air flow factor cfm/Btuh0.019 Air flow factor cfm/Btuh0.052Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.83 Bold/italic values have been manually overridden 2018-Nov-08 16:46:00 Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1 ...k up nov 18\binder heating\Scoles residence.rup Calc = MJ8 Front Door faces: W Job:AED Assessment Date:Entire House By: Tony Ledo Phone: 763-229-4252 Project Information Scoles Residence, Binder HeatingFor: 19475 Iteri Ave, Lakeville, mn Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temperature (°F)Minneapolis-St Paul Int'l Arp, MN, US 1387Design TD (°F)ft837Elevation: 5030Relative humidity (%)°N45Latitude:Outdoor:31.334.0Moisture difference (gr/lb)CoolingHeating Infiltration:88-15Dry bulb (°F))M(18-Daily range (°F) 72-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 13.1%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Job:Right-J® Worksheet Date:Entire House By:Tony Ledo Phone: 763-229-4252 1 Room name Entire House below grade 2 Exposed wall 638.0 ft 121.8 ft3Room height 10.0 dft 10.0 heat/coolft 4 Room dimensions ft1294.6x1.0 5 Room area 6357.6 ft²1294.6 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-815B-15sfc-8 0.0590.059 nn 3.953.95 0.110.11 335 335 1323 38 335 335 1323 38.WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 nn 4.354.35 0.820.82 1334 991 4311 810 0 0 0 0.GG marvin fiberglass in 0.320marvin fiberglass in 0.320 nn 27.8427.84 7.717.71 343 0 9540 2643 0 0 0 0 .WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ee 4.354.35 0.820.82 1808 1226 5332 1002 0 0 0 0 11 GG 10A-m10A-m 0.3200.320 ee 27.8427.84 15.3015.30 42 0 1169 642 0 0 0 0 GG 1A-c1omd1A-c1omd 0.3200.320 ee 27.8427.84 21.8521.85 72 0 2004 1573 0 0 0 0 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ee 27.8427.84 21.8521.85 468 0 13026 10224 0 0 0 0WW15B-15sfc-815B-15sfc-8 0.0590.059 ss 3.953.95 0.110.11 335 335 1323 38 335 335 1323 38 WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ss 4.354.35 0.820.82 938 764 3323 624 0 0 0 0GG1A-c1omd1A-c1omd 0.3200.320 ss 27.8427.84 12.9612.96 90 0 2506 1166 0 0 0 0 GG marvin fiberglass in 0.320marvin fiberglass in 0.320 ss 27.8427.84 12.9612.96 84 0 2332 1085 0 0 0 0WW15B-15sfc-815B-15sfc-8 0.0590.059 ww 3.953.95 0.110.11 548 548 2163 62 548 548 2163 62WWIECC2012 frame zone 0.050IECC2012 frame zone 0.050 ww 4.354.35 0.820.82 1057 715 3110 584 0 0 0 0 GG 10A-m10A-m 0.3200.320 ww 27.8427.84 15.3015.30 21 0 585 321 0 0 0 0GGmarvin fiberglass in 0.320marvin fiberglass in 0.320 ww 27.8427.84 21.8521.85 321 0 8930 7009 0 0 0 0 PP 12F-0sw12F-0sw 0.0650.065 --5.655.65 0.450.45 600 579 3271 258 0 0 0 0 DD 11N011N0 0.3500.350 nn 30.4530.45 8.918.91 21 21 639 187 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.741.74 0.980.98 2750 2750 4784 2692 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.482.48 0.370.37 94 94 233 35 0 0 0 0FF19C-19cscp19C-19cscp 0.0490.049 --1.481.48 0.220.22 810 810 1198 178 0 0 0 0FF21A-32t21A-32t 0.0200.020 --1.741.74 0.000.00 1295 1295 2253 0 1295 1295 2253 0 FF 22B-10tpm22B-10tpm 0.3550.355 --30.8830.88 0.000.00 551 92 2834 0 0 0 0 0 Job #: Performed for: Scoles Residence 19475 Iteri Ave Lakeville, mn Tony Ledo Phone: 763-229-4252 Scale: 1 : 123 Page 1 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Nov-08 16:46:16 ...der heating\Scoles residence.rup N lower level below grade walk out 1883 cfm 105 cfm 105 cfm 156 cfm 105 cfm Job #: Performed for: Scoles Residence 19475 Iteri Ave Lakeville, mn Tony Ledo Phone: 763-229-4252 Scale: 1 : 123 Page 2 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Nov-08 16:46:16 ...der heating\Scoles residence.rup N second floor second floor 18'-0" 10'-6" 12'-0" 15'-9" 26'-0" 16'-0" 10'-0" 15'-6" 10'-0" 8'-6"14'-0" 12'-0" 18'-0"16'-0" 152 cfm 152 cfm 152 cfm 152 cfm 152 cfm Job #: Performed for: Scoles Residence 19475 Iteri Ave Lakeville, mn Tony Ledo Phone: 763-229-4252 Scale: 1 : 123 Page 3 Right-Suite® Universal 2018 18.0.10 RSU16575 2018-Nov-08 16:46:16 ...der heating\Scoles residence.rup N main floor main floor garage 161 cfm 161 cfm 161 cfm 161 cfm161 cfm Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Ri g i d , E x t r u d e d P o l y s t y r e n e Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Fo a m O p e n C e l l Wall Ri g i d , I s o c y n u r a t e Perimeter of Slab on Grade RADON CONTROL SYSTEM To t a l R - V a l u e o f a l l T y p e s o f In s u l a t i o n Type: Check All That Apply Mi n e r a l F i b e r b o a r d Insulation Location Fo a m , C l o s e d C e l l Describe other insulated areas Ceiling, flat No n o r N o t A p p l i c a b l e Fi b e r g l a s s , B l o w n Fi b e r g l a s s , B a t t s Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 02/27/19 X KP