Loading...
HomeMy WebLinkAboutLA168269 - 19900 Henley Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: C o n c e p t A p p r o v a l O N L Y S u b j e c t t o F i e l d I n s p e c t i o n I n s p e c t o r D a t e 2 0 1 5 M N B l d g C o d e 0 4 / 2 5 / 2 0 1 9 d m a t h e w s 4 4 6 1 2 ' - 0 " U F E R G r o u n d - P r o v i d e 2 0 ' R e b a r i n f o o t i n g a n d s t u b u p n e a r e l e c t r i c a l s e r v i c e p a n e l . S m o k e 1 2 ' - 0 " 2 6 " m i n d i a m e t e r a t b a s e f o r l o a d a n d a s s u m e d 1 5 0 0 # s o i l o f f b u i l d i n g p a d . S m o k e C O S m o k e 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 333 - M i n . 1 5 " c l e a r a n c e t o a n y o b s t r u c t i o n f r o m c e n t e r o f W . C . , 2 4 " i n f r o n t ( t y p ) . Stone Cottage HVAC Load Calculations for Warbington 19900 Henley Ln Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Tuesday, March 26, 2019 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Tuesday, March 26, 2019 Client Name:Warbington Client Address:19900 Henley Ln Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Northwest Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,153 CFM Per Square ft.:0.362 Square ft. of Room Area:3,180 Square ft. Per Ton:1,143 Volume (ft³) of Cond. Space:28,620 Building Loads Total Heating Required Including Ventilation Air:46,161 Btuh 46.161 MBH Total Sensible Gain:25,042 Btuh 83 % Total Latent Gain:4,981 Btuh 17 % Total Cooling Required Including Ventilation Air:30,023 Btuh 2.50 Tons (Based On Sensible + Latent) 2.78 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.50 1,271 3,180 25,042 4,981 30,023 46,161 839 1,153 1,153 System 1 Yes 2.50 1,271 3,180 25,042 4,981 30,023 46,161 839 1,153 1,153 21x10 Ventilation 437 1,352 1,789 5,850 Zone 1 3,180 24,605 3,629 28,234 40,311 839 1,153 1,153 21x10 1-Upper Level 1,590 19,668 2,599 22,267 26,695 556 921 921 11--6 2-Lower Level 1,590 4,937 1,030 5,967 13,616 284 231 231 3--6 C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 462 12,863 0 13,286 13,286 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1512 8,550 0 1,307 1,307 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1296 5,525 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1590 2,767 0 1,526 1,526 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1190 2,588 0 0 0 Subtotals for structure:33,571 0 16,471 16,471 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 73, Summer CFM: 38 6,740 729 524 1,253 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 Total Building Load Totals:46,161 4,981 25,042 30,023 Check Figures Total Building Supply CFM:1,153 CFM Per Square ft.:0.362 Square ft. of Room Area:3,180 Square ft. Per Ton:1,143 Volume (ft³) of Cond. Space:28,620 Building Loads Total Heating Required Including Ventilation Air:46,161 Btuh 46.161 MBH Total Sensible Gain:25,042 Btuh 83 % Total Latent Gain:4,981 Btuh 17 % Total Cooling Required Including Ventilation Air:30,023 Btuh 2.50 Tons (Based On Sensible + Latent) 2.78 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 5 Building Pie Chart Building Loss 46,161 Btuh Floor 6% Roof 6% Wall 30% Glass 28% Door 3% Infiltration 15% Ventilation 13% Building Gain 30,023 Btuh Roof 5%Wall 4% Glass 44% Door 1% People 10% Equipment 25% Infiltration 4% Ventilation 6% C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 6 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 462 12,863 0 13,286 13,286 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1512 8,550 0 1,307 1,307 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1296 5,525 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1590 2,767 0 1,526 1,526 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1190 2,588 0 0 0 Subtotals for structure:33,571 0 16,471 16,471 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 73, Summer CFM: 38 6,740 729 524 1,253 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 System 1 Whole House Load Totals:46,161 4,981 25,042 30,023 Check Figures Supply CFM:1,153 CFM Per Square ft.:0.362 Square ft. of Room Area:3,180 Square ft. Per Ton:1,143 Volume (ft³) of Cond. Space:28,620 System Loads Total Heating Required Including Ventilation Air:46,161 Btuh 46.161 MBH Total Sensible Gain:25,042 Btuh 83 % Total Latent Gain:4,981 Btuh 17 % Total Cooling Required Including Ventilation Air:30,023 Btuh 2.50 Tons (Based On Sensible + Latent) 2.78 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 7 Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,590.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,590.0 sq.ft.Supply Air:921 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.9 AC/hr Volume:14,310.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:11 Actual Winter Vent.:93 CFM Runout Air:84 CFM Percent of Supply.:10 % Runout Duct Size:6 in.Actual Summer Vent.:56 CFM Runout Air Velocity:427 ft./min.Percent of Supply:6 % Runout Air Velocity:427 ft./min.Actual Winter Infil.:60 CFM Actual Loss:0.114 in.wg./100 ft.Actual Summer Infil.:31 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SE-Wall-12F-0sw 40 X 9 221 0.065 5.7 1,250 0.9 0 191 NW-Wall-12F-0sw 40 X 9 234 0.065 5.7 1,323 0.9 0 202 NE-Wall-12F-0sw 52 X 9 402 0.065 5.7 2,273 0.9 0 348 SW-Wall-12F-0sw 52 X 9 397 0.065 5.7 2,245 0.9 0 343 NW-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 NW-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 SE-Gls-4A-1a-o shgc-0.33 0%S 139 0.320 27.8 3,870 31.0 0 4,306 NW-Gls-4A-1a-o shgc-0.33 0%S 84 0.320 27.8 2,339 24.1 0 2,028 NE-Gls-4A-1a-o shgc-0.33 0%S 66 0.320 27.8 1,837 24.1 0 1,593 SW-Gls-4A-1a-o shgc-0.33 0%S 71 0.320 27.8 1,977 31.0 0 2,199 UP-Ceil-16B-50 1590 X 1 1590 0.020 1.7 2,767 1.0 0 1,526 Subtotals for Structure:21,159 0 13,088 Infil.: Win.: 59.6, Sum.: 31.0 1,656 3.343 5,536 0.260 599 430 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 5,000 Room Totals:26,695 2,599 19,668 C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 8 Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,590.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,590.0 sq.ft.Supply Air:231 CFM Ceiling Height:9.0 ft.Supply Air Changes:1.0 AC/hr Volume:14,310.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:3 Actual Winter Vent.:47 CFM Runout Air:77 CFM Percent of Supply.:20 % Runout Duct Size:6 in.Actual Summer Vent.:14 CFM Runout Air Velocity:393 ft./min.Percent of Supply:6 % Runout Air Velocity:393 ft./min.Actual Winter Infil.:13 CFM Actual Loss:0.097 in.wg./100 ft.Actual Summer Infil.:7 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SE-Wall-12F-0sw 40 X 9 258 0.065 5.7 1,459 0.9 0 223 NW-Wall-15B0-10sf-10 40 X 9 360 0.049 4.3 1,535 0.0 0 0 NE-Wall-15B0-10sf-10 52 X 9 468 0.049 4.3 1,995 0.0 0 0 SW-Wall-15B0-10sf-10 52 X 9 468 0.049 4.3 1,995 0.0 0 0 SE-Gls-4A-1a-o shgc-0.33 0%S 102 0.320 27.8 2,840 31.0 0 3,160 Floor-21A-24 1 X 1190 1190 0.025 2.2 2,588 0.0 0 0 Subtotals for Structure:12,412 0 3,383 Infil.: Win.: 13.0, Sum.: 6.7 360 3.344 1,204 0.261 130 94 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:500 1,000 Room Totals:13,616 1,030 4,937 C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 9 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Upper Level 1,590 26,695 556 11-6 427 19,668 2,599 921 921 2 Lower Level 1,590 13,616 284 3-6 393 4,937 1,030 231 231 Ventilation 5,850 437 1,352 System 1 total 3,180 46,161 839 25,042 4,981 1,153 1,153 System 1 Main Trunk Size:21x10 in. Velocity:790 ft./min Loss per 100 ft.:0.092 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.50 83% / 17%25,042 4,981 30,023 Recommended:2.78 75% / 25%25,042 8,347 33,389 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\19900 HENLEY LAKEVILLE 03262019.rhv Tuesday, March 26, 2019, 12:54 PM Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 30,023 Below Entire Slab Rig i d , E x t r u d e d P o l y s t y r e n e Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville19900 Henley Lane BC636874 Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 46,161 Heating Gain Cooling Load Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances THERMAL ENVELOPE Fo a m O p e n C e l l Wall Rig i d , I s o c y n u r a t e Perimeter of Slab on Grade RADON CONTROL SYSTEM No n o r N o t A p p l i c a b l e Cooling System To t a l R - V a l u e o f a l l T y p e s o f In s u l a t i o n Type: Check All That Apply Min e r a l F i b e r b o a r d Insulation Location Fo a m , C l o s e d C e l l 0.22 Describe other insulated areas Fi b e r g l a s s , B l o w n Fi b e r g l a s s , B a t t s Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 25,042Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 04/19/19 X KP