Loading...
HomeMy WebLinkAboutLA168478 - 17827 Essex Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 05/01/2019dmathews Secure door closed until deck is constructed with a separate permit. UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. (2)9-1/2 Versa-Lam (2)7-1/4 Versa-Lam (3)14" Versa-Lam (2)9-1/2 Versa-Lam (2)7-1/4 Versa-Lam (2 ) 1 1 - 7 / 8 V e r s a - L a m (2 ) 1 1 - 7 / 8 V e r s a - L a m 8' LIB 8' LIB 8' LIB 4' W S P 4' W S P 4' W S P 4' W S P 4' W S P 4' WSP 4' WSP PFH PFH 4' W S P 4' W S P 4' W S P 4' W S P 4' W S P Verify loads with girder truss specs, may require removal of top plates at bearing due to crushing. (2)9-1/2 Versa-Lam (2)7-1/4 Versa-Lam (2)7-1/4 Versa-Lam 5. 1 7 ' L I B 5. 1 7 ' L I B 5. 1 7 ' L I B 5. 1 7 ' L I B 5.17' LIB 5.17' LIB 5.17' LIB 2. 2 5 ' W S P 8' L I B 5. 1 7 ' L I B 2. 2 5 ' W S P 4' WSP 4' WSP 8' LIB 8' LIB -Min. 15" clearance to any obstruction from center ofW.C., 24" in front(typ). Jo i s t h a n g e r Ve r s a - L a m o r B o i s e G L U L A M b e a m : Fa c e M o u n t Be a m w i d t h s h a l l e x c e e d sp e c i f i e d h a n g e r n a i l l e n g t h ® ™ F2 7 - C Products Pl o t I D N e t Q t y P r o d u c t Length Plies J1 7 1 1 - 7 / 8 " B C I ® 4 5 0 0 s - 1 . 8 1 8 ' 0 " 1 J2 1 5 1 1 - 7 / 8 " B C I ® 4 5 0 0 s - 1 . 8 1 6 ' 0 " 1 B1 4 1 - 3 / 4 " x 7 - 1 / 4 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 6 ' 0 " 2 B2 4 1 - 3 / 4 " x 9 - 1 / 2 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 8 ' 0 " 2 B3 2 1 - 3 / 4 " x 1 1 - 7 / 8 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 2 0 ' 0 " 2 B4 4 1 - 3 / 4 " x 1 1 - 7 / 8 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 1 6 ' 0 " 2 B5 3 1 - 3 / 4 " x 1 4 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 1 6 ' 0 " 3 B6 1 G i r d e r T r u s s b y o t h e r s 3 2 ' 0 " 1 B7 1 B e a m b y o t h e r s 1 2 ' 0 " 1 B8 1 B e a m b y o t h e r s 1 0 ' 0 " 1 B9 1 B e a m b y o t h e r s 6 ' 0 " 1 B1 0 1 B e a m b y o t h e r s 4 ' 0 " 1 Ca 1 6 1 - 1 / 8 " x 1 1 - 7 / 8 " B C R I M B O A R D O S B 1 2 ' 0 " 1 Pt 1 2 P o s t b y o t h e r s 8 ' 0 " 1 Co n n e c t o r S u m m a r y Pl o t I D Q t y M a n u f P r o d u c t H1 2 S i m p s o n H U C Q 4 1 2 - S D S 2 . 5 H2 2 2 S i m p s o n M I U 1 . 8 1 / 1 1 FO Y E R F L O O R BY O T H E R S ST A I R W A Y ST A I R W A Y FL O O R T R U S S E S BY O T H E R S CA N T F L O O R CA N T F L O O R RO O F T R U S S E S BY O T H E R S RO O F T R U S S E S BY O T H E R S LV L A D D E D U N D E R WI N D O W T R I M M E R LO A D S A B O V E Pt 1 Pt 1 B5 B1 B2 B2 B1 B 1 0 B6 B3 B7 B 9 B8 B 4 B 4 C a 1 C a 1 Ca 1 Ca 1 C a 1 H 1 H 1 H2 H2 H2 J1 J2 4 ' 0 " 3 2 ' 0 " 3 8 ' 0 " 2 1 ' 6 " 1 6 ' 6 " 3 8 ' 0 " 13 ' 1 0 " 1 0 ' 0 " 1 0 ' 2 " 20 ' 0 " 54 ' 0 " 29 ' 6 " 15 ' 0 " 9 ' 6 " 54 ' 0 " 2 ' 0 " 15 ' 0 " 2 ' 0 " Sheet:1 of 2By: Anthony EstevezDate: 4-12-19Scale: 1/4" = 1'-0"BC FRAMERBoise Building Material Distribution Lakeville, MN (952) 469-5900SALES PRESENTATION DRAWING No structural or dimensional check has been made of this design drawings of the building, therefore purchaser is to check and approve all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTS TO BE VERIFIED IN THE FIELD.Revisions:BY:17827 ESSEX LANE "JASPER SPEC"BRANDL ANDERSON BUILDERS FIRSTSOURCE FLOOR FRAMING Bo i s e I - J o i s t c a n b e o f f s e t u p t o 3 " t o a v o i d v e r t i c a l p l u m b i n g . Jo i s t 3" m a x C L Jo i s t 3" m a x C L OJ - A cu t , n o t c h o r d r i l l f l a n g e s DO N O T DN 0 1 Products Pl o t I D N e t Q t y P r o d u c t Length Plies B1 2 1 - 3 / 4 " x 7 - 1 / 4 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 8 ' 0 " 2 B2 2 1 - 3 / 4 " x 7 - 1 / 4 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 6 ' 0 " 2 B3 2 1 - 3 / 4 " x 9 - 1 / 2 " V E R S A - L A M ® 2 . 0 3 1 0 0 S P 8 ' 0 " 2 B4 2 G i r d e r T r u s s b y o t h e r s 1 6 ' 0 " 1 B5 2 B e a m b y o t h e r s 6 ' 0 " 1 B6 4 B e a m b y o t h e r s 4 ' 0 " 1 ST A I R W A Y ST A I R W A Y FO Y E R RO O F T R U S S E S BY O T H E R S RO O F T R U S S E S BY O T H E R S RO O F T R U S S E S BY O T H E R S RO O F T R U S S E S BY O T H E R S B4 B 6 B 5 B2 B1 B 6 B 6 B3 B6 B4 B5 13 ' 1 0 " 3 2 ' 0 " 3 8 ' 0 " 15 ' 0 " 3 8 ' 0 " 4 ' 0 " 29 ' 6 " 54 ' 0 " 10 ' 2 " 10 ' 0 " 54 ' 0 " 3 4 ' 0 " 6 ' 0 " 15 ' 0 " 9 ' 6 " 20 ' 0 " 2 ' 0 " Sheet:2 of 2By: Anthony EstevezDate: 4-12-19Scale: 1/4" = 1'-0"BC FRAMERBoise Building Material Distribution Lakeville, MN (952) 469-5900SALES PRESENTATION DRAWING No structural or dimensional check has been made of this design drawings of the building, therefore purchaser is to check and approve all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTS TO BE VERIFIED IN THE FIELD.Revisions:BY:17827 ESSEX LANE "JASPER SPEC"BRANDL ANDERSON BUILDERS FIRSTSOURCE ROOF FRAMING 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 704 704 .23 .23 .77 .77 10.3 3.6 240 375 375 NR 3056 458 458 145 73 Date Certificate Post x Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here x R-15 x x R-20 x x R-20 x x 19+5 x x R-49 x R-49 x R-38 x R-38+5 x x X Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:44,000 Capacity in Gallons:Other, describe: AFUE or HSPF%95% Cfm's " round duct OR " metal duct Not required per mech. code X Passive x Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " Flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 15,170 R10 Rigid Exterior, R10 Int closed cell R10 Rigid Exterior, R10 Int closed cell Below Entire Slab Rig i d , E x t r u d e d P o l y s t y r e n e Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor Brandl Anderson Homes MN License Number Lakeville17827 Essex Lane BC604388 82Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 40548 Heating Gain Cooling Load Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances THERMAL ENVELOPE R5 Exterior, R19 Batts Fo a m O p e n C e l l Wall Rig i d , I s o c y n u r a t e Perimeter of Slab on Grade RADON CONTROL SYSTEM R-5 where required No n o r N o t A p p l i c a b l e Cooling System To t a l R - V a l u e o f a l l T y p e s o f In s u l a t i o n Type: Check All That Apply Mi n e r a l F i b e r b o a r d Insulation Location Fo a m , C l o s e d C e l l 0.30 Describe other insulated areas Fi b e r g l a s s , B l o w n Fi b e r g l a s s , B a t t s Foundation Wall R-value R-8 Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) 13ACXN018 Model Heating System Natural Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 11494Residential Load Calculation SEER/EER 192 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML195UH045 Heating Loss Manufacturer Lennox Natural Gas Output in Tons:1.550 Builders Associaton of Minnesota version 101014 04/23/19 X KP