Loading...
HomeMy WebLinkAbout8742 188th Street West SurveyDenotes set spikeDenotes set iron monumentDenotes found iron monumentDenotes found scribed "x"Denotes set hubDenotes proposed drainageDenotes top of curbDenotes existing elevationDenotes proposed elevationJames R. Hill, Inc. 2500 WEST C.R. 42, SUITE 120, BURNSVILLE, MN 55337 PHONE: 952.890.6044 www.jrhinc.com PLANNERS / ENGINEERS / SURVEYORS CERTIFICATE OF SURVEY FORDRAWN BYDATEREVISIONSSHP4/09/2019CAD FILEPRO-ECT NO.SHEET 1 OF 1390342.dwg390342Lot 4, Block 3, CHOKECHERRY HILL 4TH ADDITION, Dakota County, Minnesota 1.Bearings are based on the recorded plat.2.Building dimensions shown are for horizontal and vertical placement ofstructure only. See architectural plans for building and foundationdimensions.3.No specific soils investigation has been completed on this lot by JamesR. Hill, Inc. the suitability of soils to support the specific house proposedis not the responsibility of James R. Hill, Inc. or the surveyor.4.No specific title search for existence or non-existence of recorded orun-recorded easements has been conducted by the surveyor as a partof this survey. Only easements per the recorded plat are shown.5.Proposed grades shown were taken from the grading &/ordevelopment plan prepared by PIONEER engineering.6.Grading plan date/revision date: July 26, 20167.Plan No. 5486-B 'ADAMS'NOTESProposedGarage Floor @ Front= 1088.8Garage Top of Foundation= 1089.2House Top of Foundation= 1089.2Lowest Floor= 1081.2Lot 4, Block 3, CHOKECHERRY HILL 4TH ADDITION, Dakota County, MinnesotaPROPERTY DESCRIPTION8742 188th Street West, Lakeville, MinnesotaPROPERTY ADDRESSI hereby certify that this survey, plan or report was prepared by me or undermy direct supervision and that I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota. That this survey does not purport to show allimprovements, easements or encroachments, to the property except asshown thereon.Signed this 9th day of April, 2019Marcus F. Hampton, MN L.S. No. 47481SURVEYOR'S CERTIFICATEFLOOR ELEVATIONSTop nut of hydrant located at Lots 5 and 6, Block 3 = 1089.94BENCHMARKLot= 11,700 sq. ft.House/Garage= 1,936 sq. ft.Porch= 127 sq. ft.Driveway= 889 sq. ft.Sidewalk= 43 sq. ft.Patio= 18 sq. ft.Total Impervious= 3,013 sq. ft. or 25.75% of lotHARD COVER CALCULATIONSZoning = RS-3FY - 30'SY - 10' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'ENGINEERING REVIEWEDDate:__________________05/08/2019corlowsky*Draintile connection required.The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.