Loading...
HomeMy WebLinkAbout19966 Harvest Dr SurveyT W = 1 0 7 1 . 5 ( 1 0 7 2 . 3 ) ( 1 0 7 0 . 1 ) F D I P # 4 2 2 9 9 O S 2 6 . 8 7 H U B = 1 0 6 9 . 9 9 F D I P # 4 7 4 8 1 O S 3 4 . 4 2 H U B = 1 0 6 8 . 6 3 GAR FLOOR 1069.29 O S 4 6 . 0 3 H U B = 1 0 6 4 . 1 6 O S 3 5 . 5 9 H U B = 1 0 6 3 . 0 7 F D I P # 4 2 2 9 9 F D I P S E R V C . O . C.O. R : 1 0 6 8 . 9 4 E X . S O D E X . S O D 1 5 . 0 0 1 5 . 0 6 3 0 . 3 3 4 0 . 2 8 EXIST. SIDEWALK F U T U R E S I D E W A L K H A R V E S T D R I V E 1 0 1 0 1 0 1 0 5 5 5 5 8 . 2 % D R A I N A G E & U T I L I T Y E A S E M E N T E X I S T I N G H O U S E G A R A G E G A R A G E P O R C H P R O P O S E D H O U S E Δ = 1 0 ° 0 7 ' 1 0 " R = 3 8 0 . 0 0 6 7 . 1 2 S00°12'48"E 11.82 S 7 8 ° 2 0 ' 0 5 " W 1 3 8 . 6 7 1 3 0 . 0 0 N 8 9 ° 4 7 ' 1 2 " E 106.12 N00°12'48"W 2 9 . 6 7 8.00 4 . 0 0 11.83 1 6 . 1 7 24.00 2 . 0 0 12.00 3 8 . 1 7 0.16 5 . 6 7 7.50 1 1 . 0 0 16.00 3 . 0 0 15.67 1 0 . 0 0 16.50 11.00 2 . 0 0 9.00 1 1 . 1 7 ( 1 0 7 2 . 6 7 ) ( 1 0 6 4 . 5 ) ( 1 0 7 0 . 8 ) ( 1 0 6 8 . 6 ) ( 1 0 6 3 . 1 ) ( 1 0 6 0 . 6 ) ( 1 0 6 0 . 0 ) ( 1 0 7 1 . 4 ) (1068.1) ( 1 0 6 5 . 0 ) ( 1 0 6 4 . 0 ) 1 0 7 0 . 8 1 0 7 0 . 9 1 0 6 9 . 8 1 0 6 9 . 6 1067.7 1067.9 1 0 6 5 . 0 1059.7 1 0 6 8 . 4 1068.1 1 0 7 0 . 9 1 0 6 0 . 0 1 0 6 0 . 6 ( 1 0 7 0 . 3 ) 1 0 6 9 . 3 1 0 6 6 . 0 1 0 6 4 . 2 1 0 7 0 . 1 1 0 6 3 . 9 1 0 6 4 . 0 1 0 6 4 . 1 1 0 6 4 . 0 1 0 6 3 . 9 1 0 6 4 . 0 1 0 6 7 . 5 1 0 6 8 . 6 1 0 7 0 . 0 V A C A N T L O T ( 1 0 6 4 . 5 ) ( 1 0 6 4 . 5 ) ( 1 0 6 4 . 5 ) ( 1 0 6 4 . 5 ) 1 0 7 0 . 0 ( 1 0 7 2 . 3 ) 1 0 6 7 . 4 ( 1 0 6 7 . 4 ) ( 1 0 6 7 . 7 ) 1 0 6 6 . 5 F B W O B W = 1 0 6 7 . 5 T W = 1 0 7 1 . 5 B W = 1 0 7 0 . 0 S I D E W A L K E X . S O D L O O K O U T 1 0 6 4 . 0 ( 1 0 6 6 . 0 ) E X P O S E F O U N D A T I O N A S S H O W N 2 4 . 0 M A X I M U M W I T H O U T P E R M I T 1 8 . 0 DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLE DENOTES EXISTING STORM MANHOLE DENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUT DENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0 DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALL DENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION (000.0)000.0DENOTES EXISTING TREELINE DENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCE LEGENDDENOTES EXISTING F.E.S.LOT AREA : 12,218 SQ. FT.HOUSE AREA : 2,643 SQ. FT.PORCH AREA : 154 SQ. FT.DRIVEWAY AREA : 905 SQ. FT.SIDEWALK AREA : 97 SQ. FT.TOTAL IMPERVIOUS AREA : 3,799 SQ. FT. (31.1%) C E R T I F I C A T E O F S U R V E Y Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION = TOP OF FOUNDATION ELEVATION LOOKOUTS (1072.67)(1068.17)(1065.00)1. No specific soils investigation has bee n p e r f o r m e d o n t h i s l o t by the surveyor. The suitability of the soil s t o s u p p o r t t h e specific house is not the responsibility of t h e s u r v e y o r . 2.No title information was provided for thi s s u r v e y . T h i s s u r v e y does not purport to show all easements o f r e c o r d . 3. See architectural plans for final buildin g d i m e n s i o n s . AREAS:BENCHMARK: TNH AT LOT 9 BLOCK 3. ELEVATION=1076.24 NOTES 1. 8'-4" POURED FOUNDATION 2. 1064.7 MINIMUM LOW FLOOR 3. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 4. SILT FENCE AT GRADING LIMITS.= TOP OF FOUNDATION ELEVATION HOUSE(1073.00) Z o n i n g = R S - 3 F Y - 3 0 ' S Y - 1 0 ' I n t e r i o r , 2 0 ' C o r n e r R Y - 3 0 ' S Y B u f f e r - 3 0 ' R Y B u f f e r - 5 0 ' ENGINEERING RE V I E W E D Date:___________ _ _ _ _ _ _ _ 05/08/2019 c o r l o w s k y *Draintile connection r e q u i r e d . The curb box, drain tile cleanout, and c a t c h basin(if applicable) must be inspecte d a n d accepted before As-Built escrow mo n i e s w i l l be released. All structures must be fl u s h with the sod. This will be scheduled w i t h t h e landscape inspection.EROSION CONT R O L MUST BE INSTAL L E D BEFORE EXCAVA T I O N *Maintain 6" between bottom of s i d i n g a n d s o d . *No structures in ease m e n t s .