LA169073 8094 201st St W Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 05/20/2019dmathews Secure door closed until deck is constructed with a separate permit. 4' WSP 4' WSP 4' WSP 4' WSP UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. (1)11-7/8 Versa-Lam (1)11-7/8 Versa-LamVerify loads with girder truss specs, may require removal of top plates at bearing due to crushing. Remove top plates at bearing 4' WSP 3' WSP 5.17' LIB 5.17' LIB 5.17' LIB 4' WSP4' WSP4' WSP4' WSP4' WSP4' WSP4' WSP4' WSP4' WSP3.25' CS-WSP 3.25' CS-WSP PFH PFH 4' WSP8' LIB2.25' WSP 2.25' WSP 4' WSP 4' WSP 8' LIB8' LIB4' WSP8' LIB2.25' WSP -Min. 15" clearance to anyobstruction from center of W.C., 24" in front(typ). ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B3 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B4 3 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 3B5 1 Girder Truss by others 24' 0" 1B6 1 Beam by others 6' 0" 1UNEXCAVATEDFLOOR TRUSSESBY OTHERSCANTILEVEREDFLOORSTAIRWAYCONNECTIONBY OTHERSPORCH FRAMINGBY OTHERS"BEAMS BY OTHERS"IS TO BE A 2 PLY 2X10SUPPLIED BY OTHERS.B2B4B1B3B5B65' 0" 19' 0" 39' 0" 20' 0" 17' 0" 39' 0" 18' 0"20' 0"10' 0"48' 0"48' 0"29' 4"17' 0" 2' 0"15' 0" 50' 0"2' 0" Sheet:1 of 3By: Anthony EstevezDate: 4-26-19Scale: 1/4" = 1'-0"BC FRAMERBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:8094 201ST ST WSCHNAIBLE RESIDENCE"LAUREN MODEL"BRANDL ANDERSONBUILDERS FIRSTSOURCEMAIN FLOOR FRAMING required for cantilever.BCI joist blocking23/32" min. plywood/OSBinto each flange.Nail with 8d nailsor rimboard closure.®F05Boise GluLam beamsVersa-Lam or®Joist hanger™ F19START FRAMING HERE19.2" OCConnector SummaryPlotID Qty Manuf ProductH1 1 Simpson HGU5.50(H1=11)H2 1 Simpson HHUS410H3 1 Simpson HU11H4 1 Simpson HU46H5 26 Simpson IUS2.37/11.88H6 1 Simpson HGU5.50X(H1=11)H7 1 Simpson THGQH7.25-SDSProductsPlotID Net Qty ProductLength PliesJ1 8 11-7/8" BCI® 6000s-1.8 36' 0" 1J2 3 11-7/8" BCI® 6000s-1.8 34' 0" 1J3 5 11-7/8" BCI® 6000s-1.8 20' 0" 1J4 3 11-7/8" BCI® 6000s-1.8 18' 0" 1J5 16 11-7/8" BCI® 6000s-1.8 16' 0" 1B1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2B2 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B3 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B4 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 12' 0" 2B5 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B6 3 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 3B7 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 24' 0" 1B8 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 2B9 6 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 3B10 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 18' 0" 2B11 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 16' 0" 1B12 4 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 10' 0" 2B13 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 8' 0" 2B14 1 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 6' 0" 1B15 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 6' 0" 2B16 4 1-3/4" x 20" VERSA-LAM® 2.0 3100 SP 20' 0" 4B17 1 Girder Truss by others 24' 0" 1B18 4 Beam by others 4' 0" 1Ca1 8 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0" 1Bk1 1 11-7/8" BCI® 6000s-1.8 11' 0" 1Pt1 2 Post by others 8' 0" 1STAIRWAY"BEAMS BY OTHERS"IS TO BE A 2 PLY 2X10SUPPLIED BY OTHERS."H6" HANGER ATTHIS LOCATIONREQUIRES "RIGHTSIDE" FLANGE TOBE CONCEALED.Pt1Pt1B11B12B7B8B12B17B18B16B9B15B14B13B6B2B3B1B4B5B18B10B9B18B18Ca1Ca1Ca1Ca1Ca1Ca1Ca1J4J5J5J4J3J5J2J1Bk1H5H5H5H5H5H2H4H7H3H1H648' 0"39' 0" 17' 0" 5' 0" 15' 0" 39' 0" 22' 0" 2' 0"50' 0"48' 0"30' 0"18' 0"19' 0" Sheet:2 of 3By: Anthony EstevezDate: 4-26-19Scale: 1/4" = 1'-0"BC FRAMERBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:8094 201ST ST WSCHNAIBLE RESIDENCE"LAUREN MODEL"BRANDL ANDERSONBUILDERS FIRSTSOURCEUPPER FLOOR FRAMINGBoise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-Acut, notch or drill flangesDO NOTDN01 ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 10' 0" 2B3 2 Girder Truss by others 14' 0" 1B4 2 Beam by others 8' 0" 1B5 1 Beam by others 6' 0" 1B6 4 Beam by others 4' 0" 1STAIRWAYROOF TRUSSESBY OTHERS"BEAMS BY OTHERS"IS TO BE A 2 PLY 2X10SUPPLIED BY OTHERS.B3B3B4B6B4B2B6B1B5B6B636' 0" 36' 0" 12' 6" 11' 6" 14' 0"38' 0"38' 0"Sheet:3 of 3By: Anthony EstevezDate: 4-26-19Scale: 1/4" = 1'-0"BC FRAMERBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:8094 201ST ST WSCHNAIBLE RESIDENCE"LAUREN MODEL"BRANDL ANDERSONBUILDERS FIRSTSOURCEUPPER FLOOR HEADERS Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly LicensedProfessional Engineer under the laws of the State of Minnesota. License Number:1-1-19 46665Date: 5%12'1(&4#9+0)5 THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2019. (170+10)7+&' &4#9+0)+0&': SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE DETAIL S15 COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 150 9.001 January 1, 2019 S0 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 SCOPE, INDEX, & CERTIFICATION 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 &4#9+0)75')7+&'.+0'5#0&.+/+6#6+105 THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. .+/+6#6+105 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 5647%674'5%105647%6'&1(911&(.114911&411(#0&911&9#..510.;0124'%#5614 5647%674#.%10%4'6'$'#4+0)10(170+109#..5+52'4/+66'& 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. %1.&9'#6*'4)7+&'.+0'5 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. /#6'4+#.5 CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM '37+8#.'064'$#46#$.' FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 151 9.001 January 1, 2019 S1 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 DRAWING LIMITATIONS & MATERIALS 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 )'0'4#.016'5 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 152 9.001 January 1, 2019 S2 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 GENERAL NOTES 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MIN&'6#+.$3" MIN TYPCONCRETE STRIP FOOTING 11B &'6#+.# 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLY'.'8#6+10 STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 153 9.001 January 1, 2019 S3 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 STEP FOOTING DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHOR BOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 154 9.001 January 1, 2019 S4 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 WALKOUT WALL DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 155 9.001 January 1, 2019 S5 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 LOOKOUT/KNEE WALL DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4x4'-0" HOOKS @ 24" O.C. BENT OR DRILLED AND EPOXY GROUTED 3'-0"1'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT) COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 156 9.001 January 1, 2019 S6 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 UNBALANCED FOUNDATION DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING 2'4%1&'14$;$7+.&+0) &'5+)0'4, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN AT LEFT 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE %.'#4*'+)*61(Ä14.'55 (2)#4xCONT. HORIZONTAL BARS %.'#4*'+)*61(Ä14/14' (3)#4xCONT. HORIZONTAL BARS )'0'4#.564+2(116+0)5+<')7+&' ONE-STORY STRUCTURE 16" WIDE x 8" THICK 20" WIDE x 8" THICK TWO-STORY STRUCTURE 20" WIDE x 8" THICK 26" WIDE x 8" THICK 2000 PSF SOIL 1500 PSF NOTE: TABLE ABOVE IS A GENERAL FOOTING SIZE GUIDE THAT SHOULD BE VERIFIED BY HOME DESIGNER AND IS BASED ON 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 157 9.001 January 1, 2019 S7 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 BASEMENT WALL DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 )4#&'8'46+%#.$#452#%+0)(14(7..*'+)*69#..5Y(E25+ALTERNATIVE TO CODE TABLE R404.1.2'37+8#.'068'46+%#.4'$#457$56+676+106#$.'$#%-(+..6;2'CLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40) COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 158 9.001 January 1, 2019 S8 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 VERTICAL REINFORCING TABLE 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112"CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 159 9.001 January 1, 2019 S9 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 BRICK LEDGE DETAILS 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MIN64755,1+56%100'%6+10(14(7..*'+)*69#..5 $#%-(+..6;2'CLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 8'-0" 9'-0" 10'-0" 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS MECHANICAL CLIPS : SIMPSON A35/USP MPA1 14USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS MECHANICAL CLIPS : SIMPSON FWANZ* 14 USP LJQ** 14 (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1510 9.001 January 1, 2019 S10 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 FLOOR BEARING CONNECTIONS 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 #0%*14$1.6#0&010Ä$'#4+0)9#..$.1%-+0)52#%+0)(14(7..*'+)*69#..5 ALTERNATIVE TO CODE TABLE R404.1.(1) $#%-(+..6;2' CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" #.6'40#6+8'#0%*1452#%+0)(14(7..*'+)*69#..5 ALTERNATIVE TO CODE TABLE R404.1.(1) $#%-(+..6;2'CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 8'-0" 9'-0" 10'-0" 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1511 9.001 January 1, 2019 S11 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 ANCHOR SPACING TABLES 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1512 9.001 January 1, 2019 S12 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 NON BEARING JOIST BLOCKING DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1513 9.001 January 1, 2019 S13 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 NON-BEARING TRUSS BLOCKING DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 10'-0" MAX3'-8" MAX2'-6" MIN OPENING1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1514 9.001 January 1, 2019 S14 %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 WINDOW WELL DETAIL 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRADE L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2019© City: ofSheet: Drawing Date: Project Number: 1515 9.001 January 1, 2019 S15 2TQLGEV %NKGPV RevDate5+6'#&&4'55 State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 6GN 612-708-3572YYYJCPUQPITQWROPEQO %+2%10%4'6'(170+10 )7+&'.+0'&4#9+0)5 STEPPING DOWN WALL WITH GRADE &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device ) X 15 X X 20 X X 20 X X 19 + 5 X X 49 X 49 X 38 X 38 + 5 X X X Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: Heat Loss:47,198 Cfm's " round duct OR " metal duct Not required per mech. code x Passive x Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6" " round duct OR Flex " metal duct Total ventilation (intermittent + continuous) rate in cfms: Capacity continuous ventilation rate in cfms: Continuous exhausting fan(s) rated capacity in cfms: Location of duct or system:18,571 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Location of duct or system: Select a Type Energy Recover Ventilator (ERV) Capacity in cfms: Heat Recover Ventilator (HRV) Capacity in cfms: 23,118 High: High: 192 Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. R-10 Exterior & R-5 where required Interior Gas Domestic Water Heater 82 Wall Ceiling, flat Describe other insulated areas 0.30 Rheem Manufacturer Fuel Type Rating or Size Structure's Calculated Average U-Factor (excludes skylights and one door ) U: Solar Heat Gain Coefficient (SHGC):0.30 Efficiency Calculated cooling load: SEER: Heat Gain: R-10 Exterior Rigid & R-10 Interior Closed Cell Other Please Describe Here R-5 Exterior Rigid & R-19 Batts R-10 Exterior Rigid & R-10 Interior Closed Cell 50 Model ML195UH070XP36B 43VP50E2 95% Lennox Gas Select a Type 13 AFUE or HSPF% R-5 Exterior Rigid & R-38 in Cavities Output in Tons: R-value R-8 in garage area Cooling System 2.5 13ACXN030-230 Electric Lennox Bonus room over garage Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Mailing Address of the Dwelling or Dwelling Unit 8094 201st St. W Rim Joist (1st Floor+)Rigid, Extruded PolystyreneRigid, Isocynurate Below Entire Slab Fiberglass, BlownFiberglass, BattsNon or Not ApplicableFoam, Closed CellFoam Open CellMineral Fiberboard Name of Residential Contractor MN License Number Brandl Anderson Homes City Lakeville BC604388 Bay Windows or cantilevered areas Ceiling, vaulted Total R-Value of all Types of InsulationCreated by BAM version 052009 40,000 X X 40,000 1408 40,000 3000 3000 1408 3000 .47 .47 .53 40,000 40,000 13.33 13.33 .53 7.1 3.01 240 375 375 NR 3618 543 543 170 85 05/10/19 X KP