HomeMy WebLinkAboutLA171490 19841 Jersey Ave Permit Pack19841 Jersey Ave
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:26:28AM00 TitleSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044g l i n i e c k i r e s i d e n c e
LAKE MARION - PARCEL B
LAKEVILLE, MN
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2015
MN Bldg
Code
07/09/2019dmathews
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"Lower Level Window Height7' - 0"Upper Level Window Height7' - 0"Main Level Window Height8' - 0"6' - 0"2' - 5 1/2"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4"8' - 1 1/8"5/4" x 8" TRIM
A
A
A
A
A
BB C
D
D5/4" x 10" FRIEZE BD.5/4" x 10" FRIEZE BD.5/4" x 1
0" F
R
I
E
Z
E B
D
.
5/4" x 8" TRIM5/4" x 8" TRIM 5/4" x 6" FRIEZE BD.5/4" x 6" TRIM
2 1/4" STONE LINTEL
2 1/4"
STONE
CAP
2 1/4"
STONE
CAP
5/4" x 10" TRIM
0
00CUSTOM CORBEL
5/4" x 8" TRIM
24"x48" FX
BEAM PER
MFG SPEC.
@ 17'-3"
FROM T.O.F.
12' - 0"
10:12 SLOPEGarage Storage
1003' - 7 5/8"
T.O.F.
993' - 8 1/2"
4/4" x 12" TRIM
A
B B B
B
B
5/4" x 6" TRIM 5/4" x 6" TRIM5/4" x 10" F R IE Z E B D .SPIRAL
STAIRCASE
LANDING
7 1/4"7 1/4"6"3 3/4"3 1/2"7 1/4"SIDE VIEW:FRONT VIEW:
CUSTOM CORBEL
3 1/2"3 1/2"3 3/4"
2x6 WALL
2x6 TIMBERSTRAND STUDS
Opening To Vary By Door Size
Finish6 1/2"Framing5 1/2"1 1/2"Dr. Opng.2 1/2"Door to Vary by Plan
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:26:52AM01 Front & Rear ElevationsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044TYPICAL EXTERIOR
MATERIALS
SQ FT BREAKDOWN
SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS
ASPHALT SHINGLES W/
NATURAL SHADOW
ARCHITECTURAL GRADE
7" EXPOSURE
HARDIESHAKE STRAIGHT
PER ELEVATION
7" EXPOSURE HARDIELAP
SIDING PER ELEVATION
HARDIEPANEL SMOOTH
PER ELEVATION
STONE VENEER PER
ELEVATION
INSTALL KICK OUT
FLASHING & TWO
MEMBRANE TAR PAPER
BACKING IN ALL STONE
AREAS
5/4" x 6" HARDIE WINDOW &
DOOR WRAPS PER
ELEVATION
5/4" x 6" HARDIE CORNER
BOARDS PER ELEVATION
1X3 ON 1X8 COMPOSITE
FASCIA PER ELEVATION
COMPOSITE VENTED
SOFFITS PER ELEVATION
HOUSE WRAP AND/OR TAR
PAPER IN PROPER FORM
ON ENTIRE EXTERIOR
B
C
D
A
STONE
ATTACHMENT
1. VERIFY COMPLIANCE WITH
INSPECTOR WHEN PAPER IS
COMPLETE IN ONE WINDOW AREA.
2. WEATHER RESISTIVE BARRIERS:
INCLUDE 2 LAYERS OF GRADE D
PAPER WITH WEATHER RESISITVE
BARRIERS OVER WOOD BASED
SHEATHING. 15 OR 15# IS NOT
GRADE D PAPER. LAP VERTICAL
JOINTS IN PAPER AT LEAST 2
INCHES.
3. EXTERIOR OPENINGS FLASHED:
FLASH ALL EXTERIOR OPENINGS.
THE NAILING FLANGE ON WINDOWS
WILL NOT BE ACCEPTED FOR
FLASHING UNLESS THE
MANUFACTURERS INSULATION
INSTRUCTIONS ARE PROVIDED ON
SITE STATING THE FLANGE IS
ACCEPTABLE AS FLASHING.
4. WINDOW FLANGES:
INSTALL PAPER ON BOTTOM AND
SIDES OF WINDOW BEFORE
INSTALLING WINDOW. PAPER
LOCATED ON TOP OF WINDOW
SHALL GO OVER THE WINDOW
FLASHING. INSTALL A SECOND
LAYER OF PAPER OVER SIDE
WINDOW FLANGES.
5. WINDOW OPENINGS:
WATERPROOF WINDOW OPENINGS
WITH CAULK, TAPE, OR LIKE
MATERIAL. ALL OTHER OPENINGS
MUST BE WATERPROOFED WITH
CAULK, TAPE, OR LIKE MATERIAL.
6. PAPER ENTIRE WALL:
BUILDING PAPER MUST BE
INSTALLED ON ALL EXTERIOR
WALLS INCLUDING WITHIN THE
SOFFIT. INSTALL PAPER IN SHINGLE
FASHION TO ENSURE PROPER
WATER DRAINIAGE.
7. FLASHING:
AT ALL WALL/ROOF INTERSECTIONS
WHERE ROOF LINE DOES NOT
EXTEND PAST WALL, KICKOUT
FLASHING IS REQUIRED. ALL OTHER
OPENINGS MUST BE FLASHED TO
ENSURE PROPER
WATERPROOFING.
8. WEEP SCREED:
PROVIDE A CORROSION RESISTANT
WEEP SCREED WITH A MINIMUM
VERTICAL ATTACHMENT FLANGE OF
3-1/2" AT OR BELOW THE
FOUNDATION PLATE. TO ENSURE
TRAPPED WATER HAS PROPER
DRAINAGE TO EXTERIOR, SCREED
SHALL BE A TYPE THAT ALLOWS
FOR DRAINAGE AND MUST BE
PLACED A MINIMUM OF 4" ABOVE
EARTH OR 2" ABOVE CONCRETE.
PLACE WEEP SCREEDS JUST
BELOW PLATE LINE. IF PAPER HAS
BEEN INSTALLED ON FOUNDATION,
EXTEND WEEP SCREED ONTO
FOUNDATION. ALL STONE MUST
NOT EXTEND BELOW, BUT MUST
COVER, ALL LATH AND PAPER.
DAVID CHARLEZ DESIGNS DOES NOT
ACCEPT ANY RESPONSIBILITY FOR
STONE INSTALLATION OR
WATERPROOFING TECHNIQUES.
REFER TO MANUFACTURER AND
INSTALLERS FOR PREFERRED
INSTALLATION METHODS WHICH
WILL DIFFER FROM WHAT IS SHOWN.
1/4" = 1'-0"1 Front Elevation
1/4" = 1'-0"2 Rear Elevation
1 1/2" = 1'-0"4 Detail - Custom Corbel
1" = 1'-0"5 Detail- 2x6 Pocket Door Framing
3-1/2" X 7" LSL
PLANK
3-1/2" X 7" LSL
PLANK
7" X 11-7/8"
CUSTOM 2-3
WEEK LEAD TIME
2PLY 1-3/4" X
7-1/4" LSL AT 16"
O.C.
2PLY 1-3/4" X
7-1/4" LSL AT 16"
O.C.
5/4" x 10" FRIEZE BD.5/4" x 8" TRIM 5/4" x 8" TRIM
A A
B
B
B
B
B
A
5/4" x 8" TRIM
5/4" x 6" TRIM 5/4" x 6" TRIM
4/4" x 12" TRIM
B5/4" x 10" FRIEZE BD.B
STEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
5/4" x 10" FRIEZE BD.5/4" x 6" TRIM
2 1/4"
STONE
CAP
A
A
A A
B
B
B
A
D
D
D
2 1/4" STONE CAP
2 1/4"
STONE
CAP
5/4" x 8" TRIM5/4" x 8" TRIM
5 /4 " x 1 0 " F R IE Z E B D .RAILING FINISHED STONE BASE53"2 1/4" STONE CAP56"COLUMN BASE FRAMING48"COLUMN BASE FRAMING
24"
FINISHED STONE BASE
29"
2 1/4" STONE CAP
32"
COLUMN FINISHED
16"
COLUMN FRAMING
13 1/2"FINISHED40"13 1/2"FRAMING10 1/2"13 1/2"COLUMN CONSTRUCTION:
2X10 TOP/BOTTOM COLLAR
3/4" COMPOSITE WRAP
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL POST
COLUMN BASE:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL
POST
COLUMN FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
53"x29"x72" POURED CONC.
PIER ON
60"x41"x8" CONC. FOOTING
REBAR PER CODE
BEAM PER
MFG SPEC
FLUSH
BEAM PER
MFG SPEC
FLUSH
5
09
FRAMING
24"
FINISHED
29"FRAMING30"FINISHED30"2 1/4"
STONE
CAP
2" STONE
2x6 EXTERIOR WALL
WING WALL FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
29"x30"x66" POURED CONC.
PIER ON
60"x42"x8" CONC. FOOTING
REBAR PER CODE
WING WALL
CONSTRUCTION:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:19AM02 Left & Right ElevationsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"1 Left Elevation
1/4" = 1'-0"2 Right Elevation
1" = 1'-0"3 Detail - Column Plan View
3/4" = 1'-0"4 Detail - Wing Walls
TYPICAL EXTERIOR
MATERIALS
ASPHALT SHINGLES W/
NATURAL SHADOW
ARCHITECTURAL GRADE
7" EXPOSURE
HARDIESHAKE STRAIGHT
PER ELEVATION
7" EXPOSURE HARDIELAP
SIDING PER ELEVATION
HARDIEPANEL SMOOTH
PER ELEVATION
STONE VENEER PER
ELEVATION
INSTALL KICK OUT
FLASHING & TWO
MEMBRANE TAR PAPER
BACKING IN ALL STONE
AREAS
5/4" x 6" HARDIE WINDOW &
DOOR WRAPS PER
ELEVATION
5/4" x 6" HARDIE CORNER
BOARDS PER ELEVATION
1X3 ON 1X8 COMPOSITE
FASCIA PER ELEVATION
COMPOSITE VENTED
SOFFITS PER ELEVATION
HOUSE WRAP AND/OR TAR
PAPER IN PROPER FORM
ON ENTIRE EXTERIOR
B
C
D
A
6' - 10 1/2"7' - 0"9' - 3 1/4"9' - 8 3/4"7' - 6"7' - 6"6' - 0"3' - 11 1/2"3' - 0 1/2"13' - 10 1/2"19' - 0"15' - 0"13' - 0"60' - 10 1/2"6' - 0"7' - 0"3' - 0"3' - 0"8' - 0"
1' - 6"12' - 0"23' - 10"8' - 2"14' - 0"14' - 0"6' - 0"2' - 0"
37' - 4"44' - 2"
33' - 10 1/2"7' - 1 1/2"4' - 0"23' - 0"12' - 0"1' - 6"
2' - 6"4' - 0"6' - 10"
4' - 2"6' - 10"2' - 0"9' - 0"2' - 0"1' - 4 1/2"9' - 3" M.O.1' - 4 1/2"1' - 10 1/2"16' - 3" M.O.4' - 8 1/2"
36' - 6"45' - 0"
81' - 6"22' - 8 1/2"8' - 2"6' - 0"10' - 0"6' - 0"4' - 0"30' - 10 1/2"30' - 0"60' - 10 1/2"2' - 0"11' - 4 3/4"6' - 7"4' - 5 1/2"7' - 0 1/2"13' - 8 1/4"
5' - 5 1/4"5' - 8 1/4"11' - 3 3/4"20' - 8 3/4"13' - 7 3/4"9' - 5 1/2"9' - 5 1/2"5' - 6 1/2"5' - 9"4' - 0 1/4"23' - 5 1/4"3' - 9"1' - 10"4' - 1"5' - 0"5' - 9"3' - 10 1/2"5' - 5 1/2"7' - 8 1/4"13' - 4 3/4"1' - 6"2' - 1"4' - 5 1/2"14' - 8 3/4"3"3"3"3"SIMPSON METAL TIES:END JOISTS TO BEAM - LUC21OZPOST TO FOOTING - ABW66ZPOST TO BEAM - LPC6ZMIDDLE JOISTS - LUS21OZDECK RIM TO HOUSE - 3/8"x5-1/2"COATED LAG BOLTS & WASHERSINTERIOR BEARING WALLS:4X6 TREATED WOOD16"X8" FOOTING (TYPICAL)PORCH FND WALL:8'-4"x8" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODETYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL36"x36"x12"CONC. PAD(TYPICAL)SPIRAL STAIR FOOTING:18" SONO TUBE @ 42"BELOW GRADEBATHTILEFAMILY ROOMCARPETGAME ROOMCARPETDECK COLUMNS:3/4" COMPOSITE WRAP12x12 TRD. POST ON18" SONO TUBE @ 42"BELOW GRADEDIMENSIONS ARE TO EDGE OF CONCRETE AND
EDGE OF FRAMING
FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.
FLOOR SYSTEM DESIGNER VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-2" UNLESS NOTED
SET WINDOW HDRS @ 84" FROM CONCRETE FLOOR
UNLESS NOTED
NOTE:- UNEXCAVATED -- UNEX -GARAGE FND WALL:3'-6"x8" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODEMAIN FND WALL:6'-0"x8" POURED CONC.FOUNDATION ON20"X8" CONCRETE FOOTINGREBAR PER CODEINTERIOR THERMAL WALL:(UNEXPOSED WALLS ONLY)1" AIRSPACE2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.INTERIOR THERMAL WALL:(EXPOSED WALLS ONLY)1" RIGID INSULATION (R-5)2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.EXTERIOR THERMAL WALL:2" RIGID INSULATION SYSTEM (R-10) APPLIED TO EXTERIORPROVIDE FLASHINGWALK OUT WALL:2X6 STUDS @ 16" O.C.3'-6"x10" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODEPROVIDE 3 1/2"x5 1/2"POUR ON TOP OF 10" WALLUNDER 2X6 WALL2x10 JOISTS
@ 16" O.C.36"x36"x12"CONC. PAD(TYPICAL)NOTE:SOLID BLOCK ALL JOIST SPACESFIRE CAULK ALL PENETRATIONS IN SOLID BLOCK18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.MECHANICALROOMCONCRETEOSB WALLSFDWHFURNWSSUMP w/SEALEDCOVERR&SSMOKEDET.30"x80"DOORBEAM PER MFG SPECSD/COGUEST BEDROOMCARPET36"x80"
C.O.30"x80"DOORFAN42" VANITY36"x60"FBRGLSSHOWER21" LIN. CAB.BENCH & HOOKS36" REFRIGCHANGING RMTILESTORAGECONCRETEUNFINISHED36"x80"DOOR36"x80"DOOR2)30"x80"DBL DR30"x80"
DOOR
96"x80" C.O.BEAM PER MFG SPEC DROPPED3' - 0"3' - 0"STAIRSWOOD2X6 BEARING WALL2X6 BEARING WALL2X6 BEARING WALL2" SLAB LEDGE2" SLAB LEDGE
2" SLAB LEDGE2" SLAB LEDGE
2" LEDGE2" LEDGE
2" SLAB LEDGELINE OF DECK ABOVE
2X6 WALL2X6 WALL2X6 WALL2X6 BRG WALL W.O.W.O.W.O.W.O.W.O.W.O.W.O.SOLID BEARING TYPICAL8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"4063065061063071072062072084073084098"8"- UNEX -6' - 2"2' - 0"TUBBEAMS PER MFG SPEC FLUSHBEAMS PER MFG
SPEC FLUSH
BEAMS PER MFG
SPEC FLUSH
BEAMS PER MFG SPEC FLUSHUTILITY SNKSTEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
11' - 0"BEAMS PER MFG SPEC FLUSHOPEN TO
ABOVE
EXPOSED
TREADS &
RISERS
2)TW3056BEAM PER MFG SPEC.2)TW3056BEAM PER MFG SPEC.2)TW30510BEAM PER MFG SPEC.FWG60611LBEAM PER MFG SPEC.FWH31611ARBEAM PER MFG SPEC.36"x80" ST'L DR.BEAM PER MFG SPEC.2" RIGID
INSULATION
LAP SIDING
1/2" SHEATHING
2X8 CANTILEVERED
SILL PLATE
1/2" ANCHOR BOLT
BUILDING PAPER
1 1/2"
FOUNDATION WALL PULLED
INTO HOUSE 1-1/2"
2X8 CANTILEVERED SILL PLATE
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL.
FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL
PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED
CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH
GENERAL CONTRACTOR.
FLOOR TRUSSES PER PLAN
METAL FLASHING
NOTE:
FOUNDATION WALL SIZE
MAY VARY PER PROJECT.
SEE FOUNDATION PLAN 2X6 SOLE PLATE
INSULATION PER CODE
2X6 STUDS @ 16" O.C.
1/2" GYP. BRD.
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT
TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR
SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID
CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL
MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
5 1/2"4 1/2"
10"3 1/2"2" INSULATION2" INSULATION @ 45
DEGREE ANGLE
4" SAND
10" WALKOUT WALL
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL.
FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL
PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED
CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH
GENERAL CONTRACTOR.
NOTE:
LAP SIDING
PER PLAN
BUILDING PAPER
1/2" PLYWOOD
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
METAL FLASHING
1/2" GYP. BRD.
1/2" ANCHOR BOLT
2X6 SILL PLATE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT
TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR
SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID
CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL
MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:30AM03 Lower LevelSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400 SERIES) ARE
CALLED OUT BY WINDOW FRAME SIZE IN
FEET. WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING SIZES &
VERIFY EGRESS COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH ROUGH
OPENINGS. WINDOW & DOOR HEADERS TO
BE 2)2x10 UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
1" = 1'-0"2 Floor Detail - 2x8 Sill Plate
1" = 1'-0"3 Floor Detail - 10" Walkout Wall
2PLY 11-7/8" 2PLY 11-7/8"
3PLY 9-1/2" LVL
2PLY 9-1/2" LVL
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
(2)2x10
#1 SYP (2)2x10#1 SYP(2)2x10#1 SYP
14' - 0"19' - 0"15' - 0"13' - 0"2' - 0"6' - 0"14' - 0"14' - 0"8' - 0"24' - 0"12' - 0"1' - 6"12' - 0"11' - 0"8' - 0"22' - 0"4' - 0"4' - 0"34' - 0"11' - 0"23' - 0"12' - 0"1' - 6"6' - 0"10' - 0"6' - 0"7' - 0"7' - 0"9' - 3 1/4"9' - 8 3/4"7' - 6"7' - 6"6' - 3 1/4"6' - 8 3/4"62' - 0"3' - 0"3' - 0"3' - 0"11' - 0"7' - 0"7' - 0"5' - 5"2' - 7"
44' - 0"37' - 6"MICROU.C. OVEN4' - 7"2' - 11"13' - 1 1/2"13' - 4 1/2"5' - 0"8' - 0"8' - 0"2' - 0"1' - 6"4' - 6"4' - 6"1' - 6"
81' - 6"6' - 0"6' - 0"6' - 6"4' - 6"5' - 2 3/4"2' - 9 1/4"5' - 0"5' - 0"61' - 0"2' - 0"7' - 0"4' - 0"STONE BASE2' - 0"20' - 8 3/4"6' - 6"4' - 9 1/4"
16' - 8 1/4"3' - 6 1/2"2' - 5 1/2"3' - 10 1/2"7' - 5 1/4"9' - 7 3/4"4' - 1 1/2"2' - 1"7' - 0 3/4"6' - 9 1/2"2' - 7"8' - 2 1/2"6' - 5 1/2"4' - 5 1/2"4' - 6"14' - 2 3/4"4' - 7"4' - 5 1/2"4' - 6"2' - 6 1/2"7' - 8 1/4"2' - 0"4' - 5 1/2"2' - 0"8' - 3 3/4"
66"51"57 1/4"11"57 1/4"14 1/2"2' - 1 1/2"7' - 1 1/4"6' - 9 1/2"6' - 9 1/2"3"3"3"3"3"3"3"3"3"3"3"3"RAILINGSTAIRSWOODOPEN TO
BELOWRAILING
EXPOSED
TREADS &
RISERSGARAGE WALLS:INSULATE WALLS5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLSFLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.
FLOOR SYSTEM DESIGNER VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 9'-1 1/8" UNLESS NOTED
SET WINDOW HDRS @ 96" FROM MAIN LEVEL
UNLESS NOTED
NOTE:CONCRETEINSULATE WALLS& CEILINGDECKCOMPOSITEDECKINGTYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILLGARAGECOLUMN CONSTRUCTION:16x16 BOX COLUMN w/6x6 POST w/COMPOSITE WRAP36"x80" FIRE DR20 MIN RATEDBEAM PER MFG SPEC9'-0" x 8'-0" DOOR
BEAM PER MFG SPEC
UPDN16'-0" x 8'-0" DOOR
BEAM PER MFG SPEC
FRONTPORCHCONCRETEPINE T&G CLG.UPR&S HVAC CHASE2)30"x96"DOOR32"x96"
PKT DR
36"x96"
DOORBENCH & HOOKSWSHR w/FLOORDRAINDRYERUPPERSL'DRYTILESNKFANMUD ROOMTILEBATHWOODFAN48" VANITY30"x96"
DOOR
36"x96"C.O.30"x96"DOORSHELVES36" REFRIG
30" RANGE
HOOD VENT
DWSNKfoyerWOOD42"x96" ENTRY DR.BEAM PER MFG SPEC2)30"x96"DOORDESKpantryWOODkitchenWOODISLANDWOODDININGBUFFET CABINET
54"x96"
OP'NG
11'-0"x8'-0" C.O.GREAT ROOMWOODGAS FIREPLACE
PER MFG. SPECS.
BUILT
IN'S
HEARTH
BUILT
IN'S
36"x96"
C.O.OWNER'S SUITECARPETVAULTED CLG.90" VANITY 42" x 90" CUSTOMSHOWERowner's bathTILEBENCH24"
LIN.
CAB.FANFAN30"x96"C.O.36"x96"
DOOR
24"x80"GLS DR36"x96"DOOR36"x96"DOORR&SSMOKEDET.SD/COSD/COLINE OF VAULTED CLG APEXW.I.C.CARPET18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.18" FLOOR TRUSSES @ 19.2" O.C.24" FLOOR TRUSSES @ 19.2" O.C.2X6 BRG WALL2X6 PLBG WALL2X6 PLBG WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALLBEAM PER MFG. SPEC FLUSHBEAM PER
MFG. SPEC
DROPPED
BEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER
MFG. SPEC
FLUSH
FLOOR
TRUSS PER
MFG. SPEC
FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER MFG.
SPEC FLUSH
18" FLOOR TRUSSES
@ 19.2" O.C.2X6 BEARING WALL2x8 JOIST FOR STAIRCASE LANDING16"16"406306506106307107206207208407023024LINE OF CLG HGT CHANGE24' - 0"30840924"
LIN.
CAB.R&S48"x96" OP'NG w/ 2)25"x98" BARN DR.BEAM PER MFG SPEC DROPPED48" BENCH
FURNITURE
PIECE96"42"42"54"48"
ROOF TRUSSES @
24" O.C.ROOF TRUSSES @ 24" O.C.ATTIC ROOF TRUSSES @ 24" O.C.ATTIC STORAGE ACCESSLINE OF ATTIC STORAGE
PKT. OFFICEWOODBEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHUP7 RISERSALLOW FOR HVACALLOW FOR HVACALLOW FOR HVAC6"STONE BASE
3"3"2)TW30510BEAM PER MFG SPEC.3)TWT2827
BEAM PER
MFG SPEC.DHP510510BEAM PER MFG SPEC.2)TW30510BEAM PER MFG SPEC.DHP510510BEAM PER MFG SPEC.TW3046
BEAM PER
MFG SPEC.3)TW3046BEAM PER MFG SPEC.2)TW30510
BEAM PER
MFG SPEC.
DHP410510
BEAM PER
MFG SPEC.FWG9080 OXOBEAM PER MFG SPEC.TW3046
BEAM PER
MFG SPEC.2)TW28510BEAM PER MFG SPEC.2)TW28510BEAM PER MFG SPEC.3)TWT2827BEAM PER MFG SPEC.TWT2827
BEAM PER
MFG SPEC.
3" MIN. ABS OR PVC OR
EQUIVALENT
GAS TIGHT PIPE
SEAL ALL JOINTS
BETWEEN SLAB
AND FOUNDATION WALL
4" PERFORATED DRAIN
TILE W/FILTER FABRIC
8"X16" ROCK TRENCH
SEALED SUMP BASKET
MIN 6 MIL OR 3 MIL CROSS
LAMINATED POLY SHALL BE
LAPPED 12" AND PLACED BELOW
THE SLAB AND ON TOP OF 4"
MIN. SAND GAS
PERMEABLE LAYER
INSTALL LABEL READING
(RADON REDUCTION
SYSTEM) ON THE VENT PIPE
AT EACH FLOOR
AND IN ACCESSIBLE ATTICS
ALL CONTROL JOINTS,
ISOLATION JOINTS
CONSTRUCTION JOINTS
AND ANY OTHER
JOINTS IN CONCRETE
SLABS SHALL BE
SEALED WITH CAULK OR
SEALANT
SEAL ALL FLOOR
OPENINGS
ALL PIPE JOINTS AND
FITTINGS
TO BE GLUED OR TRANSITION
COUPLINGS
PROVIDE SPACE FOR
FUTURE
INSTALLATION OF A FAN
*MIN. 24' DIAMETER
CENTERED ON
THE AXIS OR THE VENT
STACK
*MIN. VERTICAL DISTANCE 36"
INSTALL LIVE OUTLET
IN ATTIC WHERE
FUTURE FAN MAY BE
INSTALLED
R-4 MIN. INSULATION
AROUND PIPE IN
UNCONDITIONED SPACES
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:32AM04 Main LevelSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400 SERIES) ARE
CALLED OUT BY WINDOW FRAME SIZE IN
FEET. WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING SIZES &
VERIFY EGRESS COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH ROUGH
OPENINGS. WINDOW & DOOR HEADERS TO
BE 2)2x10 UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
1/4" = 1'-0"2 Detail -Passive Radon System
ALL HEADERS
ARE 2X BY
OTHERS UNLESS
NOTED
OTHERWISE
3PLY 2X10 OR
2PLY 9-1/2" LVL
3PLY 2X10 OR
2PLY 9-1/2" LVL
2PLY 9-1/2" LVL
2PLY 11-7/8" LVL
2PLY 9-1/2" LVL
3PLY 14" LVL
2PLY 14" LVL
2PLY 14" LVL
2PLY 14" LVL
3PLY 14" LVL
2PLY 14" LVL
2PLY 14" LVL
THIS CANT
HAPPEN DUE TO
STEP DOWN. A
SUPPORT POST
WILL BE NEEDED
AT RAIL HEAD OF
ARROW
2PLY 14" LVL
3PLY 14" LVL
2PLY 9-1/2" LVL
3PLY 20" LVL
2PLY 9-1/2" LVL
3PLY 18" LVL
2PLY 11-7/8" LVL
SEE ELEVATION
1-3/4" X 5-1/2" LSL
AT 12" O.C.
2PLY 9-1/2" LVL
2PLY 9-1/2" LVL
2PLY 9-1/2" LVL
5-1/2" X 7" GLU-
LAM
5-1/2" X 5-1/2"
GLU-LAM
5-1/2" X 5-1/2"
GLU-LAM
Roof Trusses
per roof plan
Roof Trusses
per roof plan
CS-PF
CS-PF
CS-PF CS-PF
CS-PF
CS-PF CS-PF
CS-PF
23' - 0"10' - 5 1/2"9' - 0 1/2"5' - 6"48' - 0"6' - 0"14' - 5 1/2"7' - 0"13' - 6 1/2"19' - 5 1/2"15' - 0"48' - 0"11' - 0"14' - 0"18' - 0"
43' - 0"9' - 8 3/4"9' - 8 3/4"7' - 6"7' - 6"2' - 5 1/2"12' - 0"6' - 0"17' - 0"5' - 2 3/4"5' - 2 3/4"11' - 10"2' - 2"
4' - 3 1/4"5' - 9 1/2"3' - 11 1/4"
4' - 3"5' - 6"15' - 5 3/4"2' - 6 1/2"7' - 8 1/2"6' - 3 3/4"
2' - 5 1/2"5' - 4 1/2"5' - 9 1/2"13' - 10 1/4"5' - 1"4' - 8"5' - 4 1/4"4' - 6"5' - 2 1/4"4' - 10 1/2"3' - 6 1/2"6' - 2"14' - 8 1/4"57 1/4"11"57 1/4"48 1/2"66"51"54"17 1/2"54"2X6 WALLBEDROOM #4CARPETBEDROOM #3CARPETBEDROOM #2CARPETSMOKEDET.SMOKEDET.SMOKEDET.SD/COSD/COSTAIRSWOOD11' CLG.LOFT
WOOD 30"x80"DOOR30"x80"
DOOR
2)24"x80"DOOR30"x80"DOOR28"x80"DOORR&S28"x80"DOORR&S30"x80"DOOROPEN TO BELOWW.I.C.CARPETW.I.C.CARPETBATHTILEJ&J BATHTILE36"x60"FBRGLSSHOWERFAN30"x60"
FBRGLS
TUB/SHWR
59" VANITY42" VANITYROOF TRUSSES ARE CALLED OUT AT 24" O.C.
ROOF SYSTEM DESIGNER VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTED
SET WINDOW HDRS @ 84" FROM UPPER LEVEL
NOTE:2X6 PLMBG WALLRAILINGRAILINGATTICACCESSROOF TRUSSES @ 24" O.C.ROOF TRUSSES @
24" O.C.ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C.3"3"3"3"3"EXPOSED TREADS
& RISERS14 1/2"DN106307206207208407308409OPTIONAL DESKRECTANGLE STEEL TUBE STRINGERS, WOOD WRAPPED28"x80"DOORR&S28"x80"
DOOR
W.I.C.CARPET28"x80"DOOR24"x80"
DOORLINEN
LINE OF CLG HGT CHANGEFANRAILING2)TW3052BEAM PER MFG SPEC.2)TW3052BEAM PER MFG SPEC.TWT2827
BEAM PER
MFG SPEC.
TWT2827
BEAM PER
MFG SPEC.3)TW2852BEAM PER MFG SPEC.2)TWT281112)TW2852BEAM PER MFG SPEC.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:32AM05 Upper LevelSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400 SERIES) ARE
CALLED OUT BY WINDOW FRAME SIZE IN
FEET. WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING SIZES &
VERIFY EGRESS COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH ROUGH
OPENINGS. WINDOW & DOOR HEADERS TO
BE 2)2x10 UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
SEE ELEVATION
1-3/4" X 5-1/2" LSL
AT 16" ON
CENTER
ALL HEADERS
ARE 2X BY
OTHERS UNLESS
NOTED
OTHERWISE
1-3/4" X 5-1/2" LSL
AT 16" ON
CENTER
-Min. 15" clearance to anyobstruction from center of
W.C., 24" in front(typ).
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
SLOPED CLG.
VAULTED CLG. APEX
10"
12"
9' - 8 3/4"9' - 8 3/4"
30"
12"
13' - 6 1/2"3' - 6"8' - 2"9' - 1 1/8"8' - 1 1/8"6' - 0"29 1/2"9' - 1 1/8"13' - 9 7/16"24"
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
GIRDER TRUSS FLUSH
PER MFG. SPEC.
ROOF TRUSSES
PER MFG. SPEC.
FAMILY ROOM
GAME ROOM
GREAT
ROOM
OWNER'S SUITE
BEDROOM #3W.I.C.E.H.7 3/4"First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Roof Peak
1029' - 3"
24"
15' - 0"17' - 0"11' - 0"
14"
12"
7"
12"
24"7 1/4"8' - 7"6 1/8"9' - 2 1/4"BEAM PER MFG SPEC. FLUSH
7' - 5"5' - 6"3' - 6"3' - 6"8' - 4"8' - 2"9' - 1 1/8"8' - 1 1/8"E.H.15 15/16"14"
12"
24"
BEAM FLUSH
PER MFG. SPEC.
ALLOW FOR HVAC
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.3' - 6"BEDROOM #3 BATHW.I.C.
foyer
GREAT
ROOM
GAME ROOM STORAGE
ROOF TRUSSES
PER MFG. SPEC.
12"
First Floor
997' - 8 3/4"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Grade
993' - 2 1/2"
48"
12' - 0"12' - 0"3' - 6"GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
ATTIC ROOF TRUSSES
PER MFG. SPEC.
Garage Storage
1003' - 7 5/8"T.O.F. TO TOP PLATE9' - 1 1/8"E.H.47 3/16"8' - 1 1/8"6' - 0"12' - 0"6' - 0"
3/4" SUBFLOOR
2x10 BOTTOM CHORD ROOF
TRUSSES @ 24" O.C.
GARAGE STORAGEE.H.24 3/8"24"
First Floor
997' - 8 3/4"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Grade
993' - 2 1/2"T.O.F. TO TOP PLATE9' - 1 1/8"E.H.19 3/16"11' - 0"11' - 0"
24"24"
14"
12"3' - 6"ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
24"x48" FX
BEAM PER
MFG SPEC.T.O.F. TO WDW R.O.17' - 3"First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Grade
993' - 2 1/2"T.O.F. TO TOP PLATE11' - 1 1/8"E.H.23 3/16"12' - 0"12' - 0"
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
T.O.F. TO FIRST FLOOR48 1/4"14"
12"
TYPICAL STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
(3) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
TYPICAL STAIRCASE
LANDING CONSTRUCTION:
2-2x8 HEADER
3/4" PLYWOOD
BACKING
2x8 JOISTS @ 16" O.C.
3/4" PLYWOOD
STEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
24"12"3' - 6"11"6 11/16"DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:36AM06 Cross SectionsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"2 Cross Section - Bedroom #3
1/4" = 1'-0"1 Cross Section - Foyer/Great Rm
1/4" = 1'-0"3 Cross Section - Double Stall Garage
1/4" = 1'-0"4 Cross Section - Third Stall Garage
1/4" = 1'-0"5 Cross Section - Garage Staircase
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"
Garage Storage
1003' - 7 5/8"
T.O.F.
993' - 8 1/2"3' - 6"8' - 2"9' - 1 1/8"8' - 1 1/8"E.H.25 11/16"6' - 0"29 1/2"9' - 1 1/8"T.O.F. TO TOP PLATE9' - 1 1/8"T.O.F. TO WDW R.O.90"4' - 0 1/4"7' - 0 7/8"24 1/4"E.H.15 13/16"T.O.F. TO TOP PLATE11' - 1 1/8"20 11/16"
9' - 0"
24"
24"
24"
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.ROOF TRUSSES
PER MFG. SPEC.
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
14"
12"
14"
12"
10"
12"
14"
12"
BATH
MECHANICAL
ROOM
GUEST BEDROOM
GARAGE
MUD
ROOM kitchen
BEDROOM #4W.I.C.
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
ATTIC ROOF TRUSSES
PER MFG. SPEC.
3/4" SUBFLOOR
2x10 BOTTOM CHORD ROOF
TRUSSES @ 24" O.C.
GARAGE STORAGE
BEAM FLUSH
PER MFG. SPEC.
BEAM FLUSH
PER MFG. SPEC.
24"
12' - 0"
ROOF TRUSSES
PER MFG. SPEC.
4' - 0"
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"8' - 2"9' - 1 1/8"E.H.29 9/16"24"
8' - 0"7' - 0"7' - 0"
12"3' - 6"42"6' - 0"29 1/2"3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
DECK
ROOF TRUSSES
PER MFG. SPEC.
DECK COLUMNS:
3/4" COMPOSITE WRAP
12x12 TRD. POST ON
18" SONO TUBE @ 42"
BELOW GRADEMECH.
ROOM
CHANGING
ROOM
GARAGE
L'DRY
DINING
T.O.F. TO TOP PLATE11' - 1 1/8"24 1/4"T.O.F. TO TOP PLATE9' - 1 1/8"24"14"
12"
2x10 JOISTS @ 16" O.C.
4' - 0"
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
24"
24"
24"
17' - 0"17' - 0"
14"
12"
7"
12"
14"
12"8' - 2"9' - 1 1/8"8' - 1 1/8"E.H.15 15/16"8' - 2"9' - 1 1/8"E.H.29 9/16"CLG APEX13' - 9 7/16"8"
12"3' - 6"6' - 0"BEAM FLUSH
PER MFG. SPEC.
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
BEDROOM #2
OWNER'S SUITE
owner's
bath
W.I.C.
FAMILY ROOM STORAGE
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"8' - 1 1/8"9' - 1 1/8"8' - 2"36"11' - 1 1/8"17 RISERS10' - 7 7/8"16 RISERS9' - 8 3/4"3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
STAIRCASE
BEAM FLUSH
PER MFG. SPEC.
BEAM FLUSH
PER MFG.
SPEC.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.
2" x 2" TRIM BD.
2"
2" x 2" TRIM BD.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:38AM07 Cross SectionsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"2 Cross Section - Garage/Kitchen
1/4" = 1'-0"1 Cross Section - Laundry/Dining
1/4" = 1'-0"3 Cross Section - Owner's Suite
1/4" = 1'-0"4 Cross Section - Staircase Box Vault
1" = 1'-0"5 Stool & Apron Trim Detail
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"
38 1/2"
23' - 6 1/2"5' - 2 3/4"5' - 2 3/4"10' - 6 3/4"
18"3' - 6"8' - 2"9' - 1 1/8"E.H.11"8' - 4"23' - 5 1/4"9' - 2 1/4"12' - 7 7/8"E.H.42 1/2"14"
12"14"
12"
6"
12"
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
ROOF TRUSSES
PER MFG. SPEC.
ROOF TRUSSES
PER MFG. SPEC.
MECHANICAL
ROOM
FRONT
PORCH
L'DRYMUD ROOM
STAIRS
FRAME DOWN CLG.
TO COULMN HGT.E.H.41 3/8"11 1/4"BEAM FLUSH
PER MFG.
SPEC.
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"3' - 6"8' - 2"9' - 1 1/8"8' - 1 1/8"12"
24"
24"
24"
28' - 0"15' - 0"17 RISERS10' - 7 7/8"16 RISERS9' - 8 3/4"36"51 1/16"14 5/8"51 1/16"52 5/8"15 1/16"52 5/8"7 1/2"11' - 0"
GAP
14 1/2"25' - 9 1/4"6' - 0"1' - 10 1/8"11' - 10 7/8"12' - 0 1/4"14"
12"
15' - 0 1/2"
11"7 5/16"11"7 1/2"8" BUILD-OUTGAME ROOM
STAIRCASE
GREAT
ROOM
PKT.
OFFICE
BEDROOM #3LOFT
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
BEAM DROPPED
PER MFG. SPEC.
BEAM
FLUSH
PER MFG.
SPEC.
BEAM
FLUSH
PER MFG.
SPEC.
EXPOSED
TREADS &
RISERS
TYPICAL STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
(4) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
TYPICAL STAIRCASE
LANDING CONSTRUCTION:
2-2x8 HEADER
3/4" PLYWOOD
BACKING
2x8 JOISTS @ 16" O.C.
3/4" PLYWOOD
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
RECTANGLE
STEEL TUBE
STRINGER
SUPPORT WOOD
WRAPPED
SUSPENDED STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
RECTANGLE ST'L TUBE STRINGER, WOOD
WRAPPED w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
STAIRCASE LANDING12"24"24"24"24"12"12"
24"30"30"20 3/16"
24"12"24"24"12"12"24"12"18"24"24"24"24"12"12"6"
24"
24"12' - 0"26' - 6"
6"7' - 0"24"24"12"36"5' - 0"16' - 0"
24"30 3/4"7" / 12"14" / 12"10" / 12"10" / 12"14" / 12"6" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"ENGINEERING ROOF TRUSSES PER MFG. SPEC.
MANUFACTURE WILL PROVIDE ALL ENGINEERING
DRAWING AND SPECIFICS
OVERHANG DIMENSIONS ARE TO FACE OF
FRAMING
ICE AND WATER ALL ADJOINING ROOFS
NOTE:RIDGE VENT10:12 SLOPE6:12 SLOPESADDLE14:12 SLOPE 14:12 SLOPE14:12 SLOPE14:12 SLOPE
RIDGE VENTDRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:39AM08 Cross SectionsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"3 Cross Section - Front Porch/Laundry
1/4" = 1'-0"2 Cross Section - Staircase
341 SF
MECHANICAL ROOM
267 SF
UNFINISHED
STORAGE
1365 SF
LOWER LEVEL
858 SF
GARAGE
1997 SF
MAIN LEVEL
144 SF
DECK
80 SF
FRONT
PORCH
1102 SF
UPPER LEVEL
116 SF
STAIRCASE
3' - 6"8' - 2"18 3/4"9' - 1 1/8"18 3/4"E.H.25 11/16"20 11/16"
24"UPPER LEVEL WINDOW HEADER HEIGHT84"MAIN LEVEL WINDOW HEADER HEIGHT96"LOWER LEVEL WINDOW HEADER HEIGHT84"14"
12"
14"
12"ROOF, CEILING & EAVE
CONSTRUCTION:
WALL
CONSTRUCTION:
FOUNDATION WALL &
BASEMENT SLAB
CONSTRUCTION:
MAIN LEVEL
CONSTRUCTION:
UPPER LEVEL
CONSTRUCTION:
ARCHITECTURAL GRADE ASPHALT
SHINGLES
#15FELT & ICE & WATER SHIELD (6'-0")
1/2" OSB SHEATHING w/STEEL CLIPS
TRUSSES @ 24" O.C. (PER MFG. SPEC.)
BAFFLES w/1" AIR SPACE
2X4 LOOKOUTS
2X8 SUB FASCIA w/ 8" COMPOSITE FASCIA
COMPOSITE VENTED SOFFITS
COMPOSITE FRIEZE BOARDS
R-50 BLOWN INSULATION
POLY VAPOR BARRIER
5/8" GYP. BRD. CEILING
3/4" T&G PLYWOOD SUBFLOOR
GLUED & SCREWED
18" FLOOR TRUSSES @ 19.2" O.C.
(FLOOR SYSTEM DESIGNER TO
VERIFY SIZE & SPACING BASED
ON SPANS)
5/8" GYP. BRD. ON CEILING
SPRAY INSULATE RIMS (R-21)
SIDING PER ELEVATION
HOUSE WRAP (WRAP
WINDOWS PER MFG. SPEC.)
1/2" OSB SHEATHING
2X6 STUDS @16" O.C.
DBL. TOP PLATE
R-21 WALL INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYP. BRD.
2X6 SOLE PLATE
ALL DETAILS TO CONFORM W/
ENERGY CODE
3/4" T&G PLYWOOD SUBFLOOR
GLUED & SCREWED
18" FLOOR TRUSSES @ 19.2" O.C.
(FLOOR SYSTEM DESIGNER TO
VERIFY SIZE & SPACING BASED ON
SPANS)
FLASHING UNDER SILLS & STOOPS
TREATED 2X6 SILL PLATE w/
SEALER
1/2" ANCHOR BOLTS @ 6' O.C. & 1'
FROM CORNERS
5/8" GYP. BRD. ON CEILING
SPRAY INSULATE RIMS (R-21)
WATERPROOFING
EXTERIOR THERMAL WALL:
2" RIGID INSULATION (R-10) APPLIED TO
EXTERIOR, PROVIDE FLASHING TO
COVER EXPOSED INSULATION
POURED CONC. WALL PER PLAN
REINFORCE WALLS PER CODE AND
ENGINEER'S SPECIFICATIONS
20" X 8" CONTINUOUS CONC. FOOTING
UNLESS OTHERWISE NOTED
4" CONC. SLAB
VAPOR/MOISTURE BARRIER PER IRC
SECTION 506 EXTENDING UP THE WALL
AND SEALED TO FOUNDATION WALL
4" SAND/AGGREGATE FILL
INTERIOR & EXTERIOR 4"
DIA. PERFORATED DRAIN
TILE PIPED TO SUMP
BASKET
INTERIOR THERMAL WALL:
1" RIGID INSULATION (R-5)
2x4 STUDS @ 16" O.C.
2x4 TRD. PLATE
1/2" GYP BD.8' - 1 1/8"8' - 4"13"42"66"2 1/4"48"9' - 3 1/2"66"FRAMING
30"9' - 2 1/4"FRAMING
13 1/2"
FRAMING
13 1/2"
FRAMING
48"9 1/4"9 1/4"5 1/4"
24"
FRAMING
37 1/2"
FRAMING GAP
10 1/2"7' - 5"16 7/16"22 3/8"FRAMING38 13/16"FINISHED
30"
60.90°
BEAM PER MFG SPEC. FLUSH
ROOF TRUSSES
PER MFG. SPEC.6x6 STRUCTURAL POST14"
12"
COLUMN CONSTRUCTION:
2X10 TOP/BOTTOM COLLAR
3/4" COMPOSITE WRAP
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL POST
COLUMN BASE:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL
POST
COLUMN FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
53"x29"x72" POURED CONC.
PIER ON
60"x41"x8" CONC. FOOTING
REBAR PER CODEWING WALL FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
29"x30"x66" POURED CONC.
PIER ON
60"x42"x8" CONC. FOOTING
REBAR PER CODE
WING WALL
CONSTRUCTION:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.3/12/2019 11:27:41AM09 Square Footage CalculationsSDC - Gliniecki - CONGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044LOWER LEVEL:
SQUARE FOOTAGE
CALCULATIONS
1365 SQ. FT. LOWER LEVEL
341 SQ. FT. MECHANICAL ROOM
267 SQ. FT. UNFINISHED STORAGE
1997 SQ. FT. MAIN LEVEL
858 SQ. FT. GARAGE
144 SQ. FT. DECK
80 SQ. FT. FRONT PORCH
1102 SQ. FT. UPPER LEVEL
166 SQ. FT. STAIRCASE
4464 SQ. FT. FINISHED TOTAL
GENERAL NOTES
1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C.
2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS
OTHERWISE NOTED)
3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING
4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR.
5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD
6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND
50% AT SOFFIT-MIN
7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILER UNLESS OTHERWISE
NOTED. UNDERCUT MIN 1"
8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER.
9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF
A DOORWAY SHALL BE TEMPERED GLASS
10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR
EQUIVALENT
11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR
12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES
13. 1/2" AIR SPACE ON EACH SIDE OF MICRO-LAM BEAM & MIN 3" BEARING ON CONCRETE
14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE
TO PASS THROUGH
15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE
16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE
TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY
17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS
18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER
SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE
19. PROVIDE DRAFT STOPS PER UBC 708.3
20. FIRE BLOCK ALL CHASES AT EACH FLOOR-CEILING ASSEMBLY OR AT 10' MAX
INTERVALS
21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE
22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD
23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS
24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED
MATERIALS
25. BLOCK PATIO DOORS WITHOUT A DECK
26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC
27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES
28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE
ROOMS
29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE
STAIRS
30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN
REQUIRED (IMC703)
31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED
32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE
62-2001 6.1)
33. DRYER VENT TO THE EXTERIOR- INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER
OPENINGS: (IMC504.4, 401.52 AND 604.1)
34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD
OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS.
CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE
VAPOR BARRIER (R307)
35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE.
ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL
36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH
OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A
TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE
REQUIRED AT MIN 4" O.C.
37. 4-MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING.
FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED
38. WIND-WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING
INSULATION DAM @ CEILING CHANGES
39. WEATHER-RESISTIVE BARRIER-i.e. BUILDING WRAP TABLE R703.4
40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO
AT LEAST R-3
41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE
WEATHERED-STRIPPED AND INSULATED.
42. NEW WOOD-BURNING FIREPLACES WILL HAVE TIGHT-FITTING FLUE DAMPERS AND
OUTDOOR COMBUSTION AIR.
43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6'
ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE
FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4",
WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL
DEVICES.
44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED
WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH
SLEEPING AREA OR BEDROOM.
45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi.
46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL
MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES.
EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES
C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR
ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE
LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10".
47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY
ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND
LATERAL LOADS.
48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE
INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL
COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A
MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER-RESISTIVE
BARRIER MUST LAP OVER THE ATTACHMENT FLANGE.
49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS
1" = 10'-0"1 Basement
1" = 10'-0"2 First Floor
1" = 10'-0"3 Second Floor
1/2" = 1'-0"4 Detail - Typical Wall Section
3/8" = 1'-0"5 Detail - Column Section View
FINISHED TOTAL:
UPPER LEVEL:
MAIN LEVEL:
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:14AM00 TitleSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044g l i n i e c k i r e s i d e n c e
LAKE MARION - PARCEL B
LAKEVILLE, MN
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"Lower Level Window Height7' - 0"Upper Level Window Height7' - 0"Main Level Window Height8' - 0"6' - 0"2' - 5 1/2"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4"8' - 1 1/8"5/4" x 8" TRIM
A
A A
A
BB C
D
D5/4" x 10" FRIEZE BD.5/4" x 10" FRIEZE BD.5/4" x 1
0" F
R
I
E
Z
E B
D.
5/4" x 8" TRIM5/4" x 8" TRIM 5/4" x 6" FRIEZE BD.5/4" x 6" TRIM
2 1/4" STONE LINTEL
2 1/4"
STONE
CAP
2 1/4"
STONE
CAP
5/4" x 10" TRIM
4
01CUSTOM CORBEL
5/4" x 8" TRIM
24"x48" FX
BEAM PER
MFG SPEC.
@ 17'-3"
FROM T.O.F.
12' - 0"
10:12 SLOPEGarage Storage
1003' - 7 5/8"
T.O.F.
993' - 8 1/2"
3" BEAD BOARD
4/4" x 12" TRIM
A
B B B
B
B
5/4" x 6" TRIM 5/4" x 6" TRIM5/4" x 10" F R IE Z E B D .DROPPED BEAM PER MFG SPEC
7 1/4"7 1/4"6"3 3/4"3 1/2"7 1/4"SIDE VIEW:FRONT VIEW:
CUSTOM CORBEL
3 1/2"3 1/2"3 3/4"
2x6 WALL
2x6 TIMBERSTRAND STUDS
Opening To Vary By Door Size
Finish6 1/2"Framing5 1/2"1 1/2"Dr. Opng.2 1/2"Door to Vary by Plan
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:32AM01 Front & Rear ElevationsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044TYPICAL EXTERIOR
MATERIALS
SQ FT BREAKDOWN
SEE PAGE A09 FOR SQUARE FOOTAGE CALCULATIONS
ASPHALT SHINGLES W/
NATURAL SHADOW
ARCHITECTURAL GRADE
7" EXPOSURE
HARDIESHAKE STRAIGHT
PER ELEVATION
7" EXPOSURE HARDIELAP
SIDING PER ELEVATION
HARDIEPANEL SMOOTH
PER ELEVATION
STONE VENEER PER
ELEVATION
INSTALL KICK OUT
FLASHING & TWO
MEMBRANE TAR PAPER
BACKING IN ALL STONE
AREAS
5/4" x 6" HARDIE STOOL &
APRON WINDOW & DOOR
TRIM PER ELEVATION
(SEE DETAIL 5/07)
5/4" x 6" HARDIE CORNER
BOARDS PER ELEVATION
1X3 ON 1X8 COMPOSITE
FASCIA PER ELEVATION
COMPOSITE VENTED
SOFFITS PER ELEVATION
HOUSE WRAP AND/OR TAR
PAPER IN PROPER FORM
ON ENTIRE EXTERIOR
B
C
D
A
STONE
ATTACHMENT
1. VERIFY COMPLIANCE WITH
INSPECTOR WHEN PAPER IS
COMPLETE IN ONE WINDOW AREA.
2. WEATHER RESISTIVE BARRIERS:
INCLUDE 2 LAYERS OF GRADE D
PAPER WITH WEATHER RESISITVE
BARRIERS OVER WOOD BASED
SHEATHING. 15 OR 15# IS NOT
GRADE D PAPER. LAP VERTICAL
JOINTS IN PAPER AT LEAST 2
INCHES.
3. EXTERIOR OPENINGS FLASHED:
FLASH ALL EXTERIOR OPENINGS.
THE NAILING FLANGE ON WINDOWS
WILL NOT BE ACCEPTED FOR
FLASHING UNLESS THE
MANUFACTURERS INSULATION
INSTRUCTIONS ARE PROVIDED ON
SITE STATING THE FLANGE IS
ACCEPTABLE AS FLASHING.
4. WINDOW FLANGES:
INSTALL PAPER ON BOTTOM AND
SIDES OF WINDOW BEFORE
INSTALLING WINDOW. PAPER
LOCATED ON TOP OF WINDOW
SHALL GO OVER THE WINDOW
FLASHING. INSTALL A SECOND
LAYER OF PAPER OVER SIDE
WINDOW FLANGES.
5. WINDOW OPENINGS:
WATERPROOF WINDOW OPENINGS
WITH CAULK, TAPE, OR LIKE
MATERIAL. ALL OTHER OPENINGS
MUST BE WATERPROOFED WITH
CAULK, TAPE, OR LIKE MATERIAL.
6. PAPER ENTIRE WALL:
BUILDING PAPER MUST BE
INSTALLED ON ALL EXTERIOR
WALLS INCLUDING WITHIN THE
SOFFIT. INSTALL PAPER IN SHINGLE
FASHION TO ENSURE PROPER
WATER DRAINIAGE.
7. FLASHING:
AT ALL WALL/ROOF INTERSECTIONS
WHERE ROOF LINE DOES NOT
EXTEND PAST WALL, KICKOUT
FLASHING IS REQUIRED. ALL OTHER
OPENINGS MUST BE FLASHED TO
ENSURE PROPER
WATERPROOFING.
8. WEEP SCREED:
PROVIDE A CORROSION RESISTANT
WEEP SCREED WITH A MINIMUM
VERTICAL ATTACHMENT FLANGE OF
3-1/2" AT OR BELOW THE
FOUNDATION PLATE. TO ENSURE
TRAPPED WATER HAS PROPER
DRAINAGE TO EXTERIOR, SCREED
SHALL BE A TYPE THAT ALLOWS
FOR DRAINAGE AND MUST BE
PLACED A MINIMUM OF 4" ABOVE
EARTH OR 2" ABOVE CONCRETE.
PLACE WEEP SCREEDS JUST
BELOW PLATE LINE. IF PAPER HAS
BEEN INSTALLED ON FOUNDATION,
EXTEND WEEP SCREED ONTO
FOUNDATION. ALL STONE MUST
NOT EXTEND BELOW, BUT MUST
COVER, ALL LATH AND PAPER.
DAVID CHARLEZ DESIGNS DOES NOT
ACCEPT ANY RESPONSIBILITY FOR
STONE INSTALLATION OR
WATERPROOFING TECHNIQUES.
REFER TO MANUFACTURER AND
INSTALLERS FOR PREFERRED
INSTALLATION METHODS WHICH
WILL DIFFER FROM WHAT IS SHOWN.
1/4" = 1'-0"1 Front Elevation
1/4" = 1'-0"2 Rear Elevation
1 1/2" = 1'-0"4 Detail - Custom Corbel
1" = 1'-0"5 Detail- 2x6 Pocket Door Framing
5/4" x 10" FRIEZE BD.5/4" x 8" TRIM
A A
B
B
BB
B
A
5/4" x 8" TRIM
5/4" x 6" TRIM 5/4" x 6" TRIM
4/4" x 12" TRIM
B5/4" x 10" FRIEZE BD.B
STEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
DROPPED
BEAM PER
MFG SPEC
5/4" x 10" FRIEZE BD.5/4" x 6" TRIM
2 1/4"
STONE
CAP
A
A
A A
B
B
B
A
D
D
D
2 1/4" STONE CAP
2 1/4"
STONE
CAP
5/4" x 8" TRIM5/4" x 8" TRIM
5 /4 " x 1 0 " F R IE Z E B D .RAILING FINISHED STONE BASE53"2 1/4" STONE CAP56"COLUMN BASE FRAMING48"COLUMN BASE FRAMING
24"
FINISHED STONE BASE
29"
2 1/4" STONE CAP
32"
COLUMN FINISHED
16"
COLUMN FRAMING
13 1/2"FINISHED40"13 1/2"FRAMING10 1/2"13 1/2"COLUMN CONSTRUCTION:
2X10 TOP/BOTTOM COLLAR
3/4" COMPOSITE WRAP
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL POST
COLUMN BASE:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL
POST
COLUMN FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
53"x29"x72" POURED CONC.
PIER ON
60"x41"x8" CONC. FOOTING
REBAR PER CODE
BEAM PER
MFG SPEC
FLUSH
BEAM PER
MFG SPEC
FLUSH
5
09
FRAMING
24"
FINISHED
29"FRAMING30"FINISHED30"2 1/4"
STONE
CAP
2" STONE
2x6 EXTERIOR WALL
WING WALL FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
29"x30"x66" POURED CONC.
PIER ON
60"x42"x8" CONC. FOOTING
REBAR PER CODE
WING WALL
CONSTRUCTION:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:53AM02 Left & Right ElevationsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"1 Left Elevation
1/4" = 1'-0"2 Right Elevation
1" = 1'-0"3 Detail - Column Plan View
3/4" = 1'-0"4 Detail - Wing Walls
TYPICAL EXTERIOR
MATERIALS
B
C
D
A
ASPHALT SHINGLES W/
NATURAL SHADOW
ARCHITECTURAL GRADE
7" EXPOSURE
HARDIESHAKE STRAIGHT
PER ELEVATION
7" EXPOSURE HARDIELAP
SIDING PER ELEVATION
HARDIEPANEL SMOOTH
PER ELEVATION
STONE VENEER PER
ELEVATION
INSTALL KICK OUT
FLASHING & TWO
MEMBRANE TAR PAPER
BACKING IN ALL STONE
AREAS
5/4" x 6" HARDIE STOOL &
APRON WINDOW & DOOR
TRIM PER ELEVATION
(SEE DETAIL 5/07)
5/4" x 6" HARDIE CORNER
BOARDS PER ELEVATION
1X3 ON 1X8 COMPOSITE
FASCIA PER ELEVATION
COMPOSITE VENTED
SOFFITS PER ELEVATION
HOUSE WRAP AND/OR TAR
PAPER IN PROPER FORM
ON ENTIRE EXTERIOR
6' - 10 1/2"7' - 0"9' - 3 1/4"9' - 8 3/4"7' - 6"7' - 6"7' - 11 1/2"3' - 0 1/2"13' - 10 1/2"19' - 0"15' - 0"11' - 0"58' - 10 1/2"2' - 1 9/16"12' - 2 7/16"
1' - 6"12' - 0"23' - 10"8' - 2"14' - 0"14' - 0"6' - 0"2' - 0"
37' - 4"44' - 2"
33' - 10 1/2"7' - 1 1/2"4' - 0"23' - 0"12' - 0"1' - 6"
2' - 6"4' - 0"6' - 10"
4' - 2"6' - 10"2' - 0"9' - 0"2' - 0"1' - 4 1/2"9' - 3" M.O.1' - 4 1/2"1' - 10 1/2"16' - 3" M.O.4' - 8 1/2"
36' - 6"45' - 0"
81' - 6"22' - 8 1/2"8' - 2"6' - 0"10' - 0"6' - 0"4' - 0"30' - 10 1/2"26' - 0"2' - 0"58' - 10 1/2"2' - 0"11' - 4 3/4"6' - 7"4' - 5 1/2"7' - 0 1/2"13' - 8 1/4"
5' - 5 1/4"5' - 8 1/4"11' - 3 3/4"20' - 8 3/4"13' - 7 3/4"9' - 5 1/2"9' - 5 1/2"5' - 6 1/2"5' - 9"4' - 0 1/4"23' - 5 1/4"3' - 9"1' - 10"4' - 1"5' - 0"5' - 9"3' - 10 1/2"4' - 5 1/2"6' - 8 1/4"13' - 4 3/4"1' - 6"2' - 1"4' - 5 1/2"14' - 8 3/4"3"3"3"3"SIMPSON METAL TIES:END JOISTS TO BEAM - LUC21OZPOST TO FOOTING - ABW66ZPOST TO BEAM - LPC6ZMIDDLE JOISTS - LUS21OZDECK RIM TO HOUSE - 3/8"x5-1/2"COATED LAG BOLTS & WASHERSINTERIOR BEARING WALLS:4X6 TREATED WOOD16"X8" FOOTING (TYPICAL)PORCH FND WALL:8'-4"x8" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODETYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL36"x36"x12"CONC. PAD(TYPICAL)BATHTILEFAMILY ROOMCARPETGAME ROOMCARPETDECK COLUMNS:3/4" COMPOSITE WRAP12x12 TRD. POST ON18" SONO TUBE @ 42"BELOW GRADEDIMENSIONS ARE TO EDGE OF CONCRETE AND
EDGE OF FRAMING
FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.
FLOOR SYSTEM DESIGNER VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-2" UNLESS NOTED
SET WINDOW HDRS @ 84" FROM CONCRETE FLOOR
UNLESS NOTED
NOTE:- UNEXCAVATED -- UNEX -GARAGE FND WALL:3'-6"x8" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODEMAIN FND WALL:6'-0"x8" POURED CONC.FOUNDATION ON20"X8" CONCRETE FOOTINGREBAR PER CODEINTERIOR THERMAL WALL:(UNEXPOSED WALLS ONLY)1" AIRSPACE2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.INTERIOR THERMAL WALL:(EXPOSED WALLS ONLY)1" RIGID INSULATION (R-5)2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.EXTERIOR THERMAL WALL:2" RIGID INSULATION SYSTEM (R-10) APPLIED TO EXTERIORPROVIDE FLASHINGWALK OUT WALL:2X6 STUDS @ 16" O.C.3'-6"x10" POURED CONCRETEFOUNDATION ON20"x8" CONCRETE FOOTINGREBAR PER CODEPROVIDE 3 1/2"x5 1/2"POUR ON TOP OF 10" WALLUNDER 2X6 WALL2x12 JOISTS
@ 16" O.C.36"x36"x12"CONC. PAD(TYPICAL)NOTE:SOLID BLOCK ALL JOIST SPACESFIRE CAULK ALL PENETRATIONS IN SOLID BLOCK18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.MECHANICALROOMCONCRETEFDWHFURNWSSUMP w/SEALEDCOVERR&SSMOKEDET.30"x80"DOORBEAM PER MFG SPECSD/COGUEST BEDROOMCARPET36"x80"
C.O.30"x80"DOORFAN42" VANITY36"x48"FBRGLSSHOWER21" LIN. CAB.BENCH & HOOKS36" REFRIGCHANGING RMTILESTORAGECONCRETEUNFINISHED36"x80"DOOR36"x80"DOOR2)30"x80"DBL DR30"x80"
DOOR
96"x80" C.O.BEAM PER MFG SPEC DROPPEDSTAIRSWOOD2X6 BEARING WALL2X6 BEARING WALL2X6 BEARING WALL2" SLAB LEDGE2" SLAB LEDGE
2" SLAB LEDGE2" SLAB LEDGE
2" LEDGE2" LEDGE
2" SLAB LEDGELINE OF DECK ABOVE
2X6 WALL2X6 WALL2X6 WALL2X6 BRG WALL W.O.W.O.W.O.W.O.W.O.W.O.W.O.SOLID BEARING TYPICAL8"8"8"8"8"8"8"
8"8"8"
8"
8"8"8"8"8"8"4063065061063071072062072084073084098"8"- UNEX -3' - 5"4' - 9"11' - 3"2' - 9"
BEAMS PER MFG
SPEC FLUSH
UTILITY SNKSTEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
11' - 0"BEAMS PER MFG SPEC FLUSHOPEN TO
ABOVE
EXPOSED
TREADS &
RISERS
2)TW3056BEAM PER MFG SPEC.2)TW3056BEAM PER MFG SPEC.2)TW30510BEAM PER MFG SPEC.FWG60611LBEAM PER MFG SPEC.FWH31611ARBEAM PER MFG SPEC.42"x80" ST'L DR.BEAM PER MFG SPEC.W.O.
W.O.36"x36"x12"CONC. PAD(TYPICAL)32"x80"PKT DR.2X6 WALLTWT2827
BEAM PER
MFG SPEC.BEAMS PER MFG SPEC DROPPEDCANT ABOVEC A N T
2 4 "
18"27 5/8"
3 2 1 1 /1 6 "120"19 7/16"112 9/16"2" RIGID
INSULATION
LAP SIDING
1/2" SHEATHING
2X8 CANTILEVERED
SILL PLATE
1/2" ANCHOR BOLT
BUILDING PAPER
1 1/2"
FOUNDATION WALL PULLED
INTO HOUSE 1-1/2"
2X8 CANTILEVERED SILL PLATE
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL.
FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL
PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED
CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH
GENERAL CONTRACTOR.
FLOOR TRUSSES PER PLAN
METAL FLASHING
NOTE:
FOUNDATION WALL SIZE
MAY VARY PER PROJECT.
SEE FOUNDATION PLAN 2X6 SOLE PLATE
INSULATION PER CODE
2X6 STUDS @ 16" O.C.
1/2" GYP. BRD.
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT
TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR
SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID
CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL
MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
5 1/2"4 1/2"
10"3 1/2"2" INSULATION2" INSULATION @ 45
DEGREE ANGLE
4" SAND
10" WALKOUT WALL
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL.
FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL
PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED
CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH
GENERAL CONTRACTOR.
NOTE:
LAP SIDING
PER PLAN
BUILDING PAPER
1/2" PLYWOOD
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
METAL FLASHING
1/2" GYP. BRD.
1/2" ANCHOR BOLT
2X6 SILL PLATE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT
TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR
SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID
CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL
MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:54AM03 Lower LevelSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400 SERIES) ARE
CALLED OUT BY WINDOW FRAME SIZE IN
FEET. WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING SIZES &
VERIFY EGRESS COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH ROUGH
OPENINGS. WINDOW & DOOR HEADERS TO
BE 2)2x10 UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
1" = 1'-0"2 Floor Detail - 2x8 Sill Plate
1" = 1'-0"3 Floor Detail - 10" Walkout Wall
14' - 0"19' - 0"15' - 0"11' - 0"2' - 0"6' - 0"14' - 0"14' - 0"8' - 0"24' - 0"12' - 0"1' - 6"12' - 0"11' - 0"8' - 0"22' - 0"4' - 0"2' - 0"34' - 0"11' - 0"23' - 0"12' - 0"1' - 6"6' - 0"10' - 0"6' - 0"7' - 0"7' - 0"9' - 3 1/4"9' - 8 3/4"7' - 6"7' - 6"5' - 3 1/4"5' - 8 3/4"3' - 0"3' - 0"14' - 0"7' - 0"7' - 0"5' - 0"3' - 0"
44' - 0"37' - 6"MICROU.C. OVEN7' - 6"13' - 1 1/2"13' - 4 1/2"5' - 0"8' - 0"8' - 0"2' - 0"1' - 6"4' - 6"4' - 6"1' - 6"
81' - 6"6' - 0"6' - 0"6' - 6"4' - 6"5' - 2 3/4"2' - 9 1/4"5' - 0"5' - 0"59' - 0"2' - 0"7' - 0"4' - 0"STONE BASE2' - 0"20' - 8 3/4"6' - 6"4' - 9 1/4"
14' - 8 1/4"3' - 0"2' - 6 1/2"2' - 5 1/2"3' - 11 1/2"7' - 4 1/4"5' - 11 1/2"3' - 8 1/4"4' - 1 1/2"2' - 1"7' - 0 3/4"6' - 9 1/2"2' - 7"8' - 2 1/2"6' - 5 1/2"4' - 5 1/2"4' - 0"1' - 9 1/4"10' - 11 1/2"4' - 7"4' - 5 1/2"4' - 0"3' - 0 1/2"7' - 8 1/4"2' - 0"4' - 6 1/2"1' - 11"8' - 3 3/4"
66"51"57 1/4"11"57 1/4"14 1/2"2' - 1 1/2"7' - 1 1/4"6' - 9 1/2"6' - 9 1/2"3"3"3"3"3"3"3"3"3"3"3"3"RAILINGSTAIRSWOODOPEN TO
BELOWRAILING
EXPOSED
TREADS &
RISERSGARAGE WALLS:INSULATE WALLS5/8" TYPE X GP. BD. ON ALL INTERIOR GARAGE WALLSFLOOR TRUSSES ARE CALLED
OUT AT 19.2" O.C.
FLOOR SYSTEM DESIGNER
VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 9'-1 1/8"
UNLESS NOTED
SET WINDOW HDRS @ 96" FROM
MAIN LEVEL UNLESS NOTED
NOTE:CONCRETEINSULATE WALLS& CEILINGDECKCOMPOSITEDECKINGTYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILLGARAGECOLUMN CONSTRUCTION:16x16 BOX COLUMN w/6x6 POST w/COMPOSITE WRAP36"x80" FIRE DR20 MIN RATEDBEAM PER MFG SPEC9'-0" x 8'-0" DOOR
BEAM PER MFG SPEC
UPDN16'-0" x 8'-0" DOOR
BEAM PER MFG SPEC
FRONTPORCHCONCRETEPINE T&G CLG.UPR&S HVAC CHASE2)30"x80"DOOR36"x80"
PKT DR
36"x80"PKT DRBENCH & HOOKSWSHR w/FLOORDRAINDRYERUPPERSL'DRYTILESNKFANMUD ROOMTILEBATHWOODFAN42" VANITY36"x80"
PKT DR.36"x96"C.O.36"x80"DOORSHELVES36" REFRIG
30" RANGE
HOOD VENT
DWSNKfoyerWOOD42"x96" ENTRY DR.BEAM PER MFG SPEC2)30"x80"DOORDESKpantryWOODkitchenWOODISLANDWOODDININGBUFFET CABINET 54"x96"
OP'NG
11'-0"x8'-0" C.O.GREAT ROOMWOOD4"x6"COFFEREDCLG. w/ CROWNGAS FIREPLACE
PER MFG. SPECS.
BUILT
IN'S
HEARTH
BUILT
IN'S
36"x96"
C.O.OWNER'S SUITECARPETVAULTED CLG.90" VANITY 42" x 90" CUSTOMSHOWERowner's bathTILEBENCH24"
LIN.
CAB.FANFAN36"x80"DOOR36"x80"
DOOR
36"x80"GLS DR36"x80"DOOR36"x80"PKT DRR&SSMOKEDET.SD/COSD/COLINE OF VAULTED CLG APEXW.I.C.CARPET14" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR TRUSSES
@ 19.2" O.C.
18" FLOOR
TRUSSES @
19.2" O.C.
24" FLOOR TRUSSES
@ 19.2" O.C.2X6 BRG WALL2X6 PLBG WALL2X6 PLBG WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALLBEAM PER MFG. SPEC FLUSHBEAM PER
MFG. SPEC
DROPPED
BEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER
MFG. SPEC
FLUSH
FLOOR
TRUSS PER
MFG. SPEC
FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHBEAM PER MFG.
SPEC FLUSH
18" FLOOR TRUSSES
@ 19.2" O.C.2X6 BEARING WALL2x8 JOIST FOR STAIRCASE LANDING16"16"406306506106307107206207208407023024LINE OF CLG HGT CHANGE4' - 0"3' - 8"4' - 0"12' - 4"30840924"
LIN.
CAB.R&S48"x80" OP'NG w/ 2)25"x84" BARN DR.BEAM PER MFG SPEC DROPPED48" BENCH
FURNITURE
PIECE96"42"42"54"48"
ROOF TRUSSES @
24" O.C.ROOF TRUSSES @ 24" O.C.ATTIC ROOF TRUSSES @ 24" O.C.ATTIC STORAGE ACCESSLINE OF ATTIC STORAGE
PKT. OFFICEWOODBEAM PER MFG. SPEC FLUSHBEAM PER MFG. SPEC FLUSHUP8 RISERSALLOW FOR HVACALLOW FOR HVACALLOW FOR HVACSTONE BASE
3"3"2)TW30510BEAM PER MFG SPEC.3)TWT2827
BEAM PER
MFG SPEC.DHP510510BEAM PER MFG SPEC.2)TW30510BEAM PER MFG SPEC.DHP510510BEAM PER MFG SPEC.TW3046
BEAM PER
MFG SPEC.2)TW3046BEAM PER MFG SPEC.2)TW30510
BEAM PER
MFG SPEC.
DHP410510
BEAM PER
MFG SPEC.FWG9080 OXOBEAM PER MFG SPEC.TW3046
BEAM PER
MFG SPEC.2)TW28510BEAM PER MFG SPEC.2)TW28510BEAM PER MFG SPEC.3)TWT2827BEAM PER MFG SPEC.TWT2827
BEAM PER
MFG SPEC.& PULL-DOWN STAIRCASENOTE:LIGHT GRAY WALLS TO INDICATE GREAT ROOM WALLS TO BE FRAMED TO 9' - 5 1/8" FROM M.L. TO 14" TRUSSES ABOVE TO ALLOW FOR FLUSH COFFERED CLG.6"57 13/16"6"57 13/16"6"57 13/16"6"6"70 1/2"6"74"6"71"6"GRAY REGION AT B.I.'s TO INDICATE FRAMED DOWN FOFIT TO 9'-1 1/8"18" FLOOR TRUSSES
@ 19.2" O.C.CEILING UPSET CENTER ON KITCHEN ISLANDSHIPLAP CLG.3"3"4-5) 12" DEPTH SHELVESDHP3046BEAM PER MFG SPEC.42"
42"2x6 WALLR.I. ELECTRICAL PANEL FOR ELECTRIC CAR
(LOCATION DETERMINED BY HOME OWNER)STAIRCASE LANDING TO MATCH MAIN LEVEL27 5/8"18"19 7/16"112 9/16"10' - 0"3' - 5 5/8"14' - 4"
RAILINGS PER CODE
(OUTSIDE)
3" MIN. ABS OR PVC OR
EQUIVALENT
GAS TIGHT PIPE
SEAL ALL JOINTS
BETWEEN SLAB
AND FOUNDATION WALL
4" PERFORATED DRAIN
TILE W/FILTER FABRIC
8"X16" ROCK TRENCH
SEALED SUMP BASKET
MIN 6 MIL OR 3 MIL CROSS
LAMINATED POLY SHALL BE
LAPPED 12" AND PLACED BELOW
THE SLAB AND ON TOP OF 4"
MIN. SAND GAS
PERMEABLE LAYER
INSTALL LABEL READING
(RADON REDUCTION
SYSTEM) ON THE VENT PIPE
AT EACH FLOOR
AND IN ACCESSIBLE ATTICS
ALL CONTROL JOINTS,
ISOLATION JOINTS
CONSTRUCTION JOINTS
AND ANY OTHER
JOINTS IN CONCRETE
SLABS SHALL BE
SEALED WITH CAULK OR
SEALANT
SEAL ALL FLOOR
OPENINGS
ALL PIPE JOINTS AND
FITTINGS
TO BE GLUED OR TRANSITION
COUPLINGS
PROVIDE SPACE FOR
FUTURE
INSTALLATION OF A FAN
*MIN. 24' DIAMETER
CENTERED ON
THE AXIS OR THE VENT
STACK
*MIN. VERTICAL DISTANCE 36"
INSTALL LIVE OUTLET
IN ATTIC WHERE
FUTURE FAN MAY BE
INSTALLED
R-4 MIN. INSULATION
AROUND PIPE IN
UNCONDITIONED SPACES
2X6 SILL PLATE
1/2" ANCHOR BOLT6"2"6"2" RIGID
INSULATION
5/8" TYPE X
GYP. BRD.
FLOOR TRUSSES PER PLAN
2X6 SOLE PLATE
3-1/2" POURED
CONCRETE SLAB
NOTE:
FOUNDATION WALL SIZE
MAY VARY PER PROJECT.
SEE FOUNDATION PLAN
garage common wall
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL.
FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL
PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED
CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH
GENERAL CONTRACTOR.
NOTE:3 1/2"1/2" GYP. BRD.
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT
TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR
SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID
CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL
MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:55AM04 Main LevelSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400
SERIES) ARE CALLED OUT BY
WINDOW FRAME SIZE IN FEET.
WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING
SIZES & VERIFY EGRESS
COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH
ROUGH OPENINGS. WINDOW &
DOOR HEADERS TO BE 2)2x10
UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
1/4" = 1'-0"2 Detail -Passive Radon System
1" = 1'-0"3 Floor Detail - Garage Comon Wall
23' - 0"10' - 5 1/2"9' - 0 1/2"5' - 6"48' - 0"6' - 0"14' - 5 1/2"7' - 0"15' - 6 1/2"13' - 6 1/2"19' - 5 1/2"15' - 0"48' - 0"11' - 0"14' - 0"18' - 0"
43' - 0"9' - 8 3/4"9' - 8 3/4"7' - 6"7' - 6"2' - 5 1/2"12' - 0"6' - 0"17' - 0"5' - 2 3/4"5' - 2 3/4"11' - 10"2' - 2"
4' - 3 1/4"5' - 9 1/2"3' - 11 1/4"
4' - 3"5' - 6"15' - 5 3/4"2' - 6 1/2"7' - 9 1/2"6' - 2 3/4"
2' - 5 1/2"5' - 4 1/2"5' - 9 1/2"13' - 10 1/4"5' - 1"4' - 5 1/4"5' - 7"4' - 6"5' - 1 1/4"4' - 8 3/4"3' - 6 1/2"6' - 4 3/4"14' - 8 1/4"57 1/4"11"57 1/4"48 1/2"66"51"54"17 1/2"54"2X6 WALLBEDROOM #4CARPETBEDROOM #3CARPETBEDROOM #2CARPETSMOKEDET.SMOKEDET.SMOKEDET.SD/COSD/COSTAIRSWOOD11' CLG.LOFT
WOOD 30"x80"DOOR30"x80"
DOOR
2)24"x80"DOOR30"x80"DOOR28"x80"DOORR&S28"x80"DOORR&S30"x80"DOOROPEN TO
BELOW W.I.C.CARPETW.I.C.CARPETBATHTILEJ&J BATHTILE36"x60"FBRGLSSHOWERFAN30"x60"
FBRGLS
TUB/SHWR
72" VANITY42" VANITYROOF TRUSSES ARE CALLED OUT AT 24" O.C.
ROOF SYSTEM DESIGNER VERIFY SPACING AND
ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTED
SET WINDOW HDRS @ 84" FROM UPPER LEVEL
NOTE:2X6 PLMBG WALLRAILINGRAILINGATTICACCESSROOF TRUSSES @ 24" O.C.ROOF TRUSSES @
24" O.C.
ROOF TRUSSES @
24" O.C.ROOF TRUSSES @ 24" O.C.3"3"3"3"3"EXPOSED TREADS
& RISERS
14 1/2"DN106307206207208407308409OPTIONAL DESKRECTANGLE STEEL TUBE STRINGERS, WOOD WRAPPED28"x80"DOORR&S28"x80"
DOOR
W.I.C.CARPET28"x80"DOOR28"x80"PKT DRLINENLINE OF CLG HGT CHANGEFANRAILING2)TW3052BEAM PER MFG SPEC.2)TW3052BEAM PER MFG SPEC.TWT2827
BEAM PER
MFG SPEC.
TWT2827
BEAM PER
MFG SPEC.3)TW2852BEAM PER MFG SPEC.2)TWT281112)TW2852BEAM PER MFG SPEC.NOTE:GRAY REGION TO INDICATE 14" FLOOR TRUSSEDS BELOW FOR GREAT ROOM COFFERED CEILING2X6 WALLDRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:55AM05 Upper LevelSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044NOTE:
ANDERSEN WINDOWS (400 SERIES) ARE
CALLED OUT BY WINDOW FRAME SIZE IN
FEET. WINDOW MANUFACTURER TO
SPECIFY CLOSEST MATCHING SIZES &
VERIFY EGRESS COMPLIANCE AND PROVIDE
WINDOW SCHEDULE WITH ROUGH
OPENINGS. WINDOW & DOOR HEADERS TO
BE 2)2x10 UNLESS NOTED (PER MFG.
SPECS.)
ATTENTION:
BEAM SIZES & ALL STRUCTURAL
CONSIDERATIONS SPECIFIED ON THIS SET
OF PLANS MUST BE REVIEWED BY THE
FLOOR SYSTEM DESIGNER OR BY A
STRUCTURAL ENGINEER AND CONFIRMED
TO BE STRUCTURALLY SOUND. BASED ON
THAT REVIEW IF THERE ARE ANY CHANGES
OR ADDED BEAM SIZES, LOCATION , ETC.
THESE CHANGES MUST BE BROUGHT TO
THE GENERAL CONTRACTORS ATTENTION:
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
SLOPED CLG.
VAULTED CLG. APEX
10"
12"
9' - 8 3/4"9' - 8 3/4"
30"
12"
13' - 6 1/2"3' - 6"8' - 2"6' - 0"29 1/2"9' - 1 1/8"13' - 9 7/16"24"
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
14" FLOOR TRUSSES @ 19.2" O.C.
GIRDER TRUSS FLUSH
PER MFG. SPEC.
ROOF TRUSSES
PER MFG. SPEC.
FAMILY ROOM
GAME ROOM
GREAT
ROOM
OWNER'S SUITE
BEDROOM #3W.I.C.E.H.7 3/4"Great Room Clg. Hgt.9' - 5 1/8"4"4"8' - 1 1/8"First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Roof Peak
1029' - 3"
24"
15' - 0"17' - 0"11' - 0"
14"
12"
7"
12"
24"7 1/4"8' - 7"6 1/8"9' - 2 1/4"BEAM PER MFG SPEC. FLUSH
7' - 5"5' - 6"3' - 6"3' - 6"8' - 4"8' - 2"9' - 5 1/8"8' - 1 1/8"E.H.15 15/16"14"
12"
24"
BEAM FLUSH
PER MFG. SPEC.
ALLOW FOR HVAC
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
14" FLOOR TRUSSES @ 19.2" O.C.3' - 6"BEDROOM #3 BATHW.I.C.
foyer
GREAT
ROOM
GAME ROOM STORAGE
ROOF TRUSSES
PER MFG. SPEC.
12"
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
First Floor
997' - 8 3/4"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Grade
993' - 2 1/2"
48"
12' - 0"12' - 0"3' - 6"GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
ATTIC ROOF TRUSSES
PER MFG. SPEC.
Garage Storage
1003' - 7 5/8"T.O.F. TO TOP PLATE9' - 1 1/8"E.H.47 3/16"8' - 1 1/8"6' - 0"12' - 0"6' - 0"
3/4" SUBFLOOR
2x10 BOTTOM CHORD ROOF
TRUSSES @ 24" O.C.
GARAGE STORAGEE.H.24 3/8"24"
14"
12"
First Floor
997' - 8 3/4"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Grade
993' - 2 1/2"T.O.F. TO TOP PLATE9' - 1 1/8"E.H.19 3/16"11' - 0"11' - 0"
24"24"
14"
12"3' - 6"ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
24"x48" FX
BEAM PER
MFG SPEC.T.O.F. TO WDW R.O.17' - 3"First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Grade
993' - 2 1/2"T.O.F. TO TOP PLATE11' - 1 1/8"E.H.23 3/16"12' - 0"12' - 0"
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED
TOWARDS OVERHEAD DOOR
SAND BED GRANULAR FILL
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
GARAGE
T.O.F. TO FIRST FLOOR48 1/4"14"
12"
TYPICAL STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
(3) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
TYPICAL STAIRCASE
LANDING CONSTRUCTION:
2-2x8 HEADER
3/4" PLYWOOD
BACKING
2x8 JOISTS @ 16" O.C.
3/4" PLYWOOD
STEPPED FOUNDATION
VERIFY LOCATION WITH
SURVEYING ENGINEER
24"12"3' - 6"DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:56AM06 Cross SectionsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"2 Cross Section - Bedroom #3
1/4" = 1'-0"1 Cross Section - Foyer/Great Rm
1/4" = 1'-0"3 Cross Section - Double Stall Garage
1/4" = 1'-0"4 Cross Section - Third Stall Garage
1/4" = 1'-0"5 Cross Section - Garage Staircase
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"
Garage Storage
1003' - 7 5/8"
T.O.F.
993' - 8 1/2"3' - 6"8' - 2"9' - 1 1/8"8' - 1 1/8"E.H.25 11/16"6' - 0"29 1/2"9' - 1 1/8"T.O.F. TO TOP PLATE9' - 1 1/8"T.O.F. TO WDW R.O.90"4' - 0 1/4"7' - 0 7/8"24 1/4"E.H.15 13/16"T.O.F. TO TOP PLATE11' - 1 1/8"20 11/16"
9' - 0"
24"
24"
24"
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.ROOF TRUSSES
PER MFG. SPEC.
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
14"
12"
14"
12"
10"
12"
14"
12"
BATH
MECHANICAL
ROOM
GUEST BEDROOM
GARAGE
MUD
ROOM kitchen
BEDROOM #4W.I.C.
GARAGE WALLS:
INSULATE WALLS
5/8" TYPE X GP. BD.
ON ALL INTERIOR
GARAGE WALLS
ATTIC ROOF TRUSSES
PER MFG. SPEC.
3/4" SUBFLOOR
2x10 BOTTOM CHORD ROOF
TRUSSES @ 24" O.C.
GARAGE STORAGE
BEAM FLUSH
PER MFG. SPEC.
BEAM FLUSH
PER MFG. SPEC.
24"
12' - 0"
ROOF TRUSSES
PER MFG. SPEC.
4' - 0"8' - 1 1/8"24"10' - 3"5' - 0"5' - 9"6"KITCHEN ISLAND UPSET
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"8' - 2"9' - 1 1/8"E.H.29 9/16"24"
8' - 0"7' - 0"7' - 0"
12"3' - 6"42"6' - 0"29 1/2"3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
DECK
ROOF TRUSSES
PER MFG. SPEC.
DECK COLUMNS:
3/4" COMPOSITE WRAP
12x12 TRD. POST ON
18" SONO TUBE @ 42"
BELOW GRADE
MECH.
ROOM
CHANGING
ROOM
GARAGE
L'DRY
DINING
T.O.F. TO TOP PLATE11' - 1 1/8"24 1/4"T.O.F. TO TOP PLATE9' - 1 1/8"24"14"
12"
2x12 JOISTS @ 16" O.C.
4' - 0"
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
24"
24"
24"
17' - 0"17' - 0"
14"
12"
7"
12"
14"
12"8' - 2"9' - 1 1/8"8' - 1 1/8"E.H.15 15/16"8' - 2"9' - 1 1/8"E.H.29 9/16"CLG APEX13' - 9 7/16"8"
12"3' - 6"6' - 0"BEAM FLUSH
PER MFG. SPEC.
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
BEDROOM #2
OWNER'S SUITE
owner's
bath
W.I.C.
FAMILY ROOM STORAGE
First Floor
997' - 8 3/4"
Second Floor1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"8' - 1 1/8"9' - 1 1/8"8' - 2"36"11' - 1 1/8"17 RISERS10' - 7 7/8"16 RISERS9' - 8 3/4"3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
STAIRCASE
BEAM FLUSH
PER MFG. SPEC.
BEAM FLUSH
PER MFG.
SPEC.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.5/4" x 6" TRIM BD.
2" x 2" TRIM BD.
2"
2" x 2" TRIM BD.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:44:57AM07 Cross SectionsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"2 Cross Section - Garage/Kitchen
1/4" = 1'-0"1 Cross Section - Laundry/Dining
1/4" = 1'-0"3 Cross Section - Owner's Suite
1/4" = 1'-0"4 Cross Section - Staircase Box Vault
1" = 1'-0"5 Stool & Apron Trim Detail
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"
38 1/2"
23' - 6 1/2"5' - 2 3/4"5' - 2 3/4"10' - 6 3/4"
18"3' - 6"8' - 2"9' - 1 1/8"E.H.11"8' - 4"23' - 5 1/4"9' - 2 1/4"12' - 7 7/8"E.H.42 1/2"14"
12"14"
12"
6"
12"
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
ROOF TRUSSES
PER MFG. SPEC.
ROOF TRUSSES
PER MFG. SPEC.
MECHANICAL
ROOM
FRONT
PORCH
L'DRYMUD ROOM
STAIRS
FRAME DOWN CLG.
TO COULMN HGT.E.H.41 3/8"11 1/4"BEAM FLUSH
PER MFG.
SPEC.
First Floor
997' - 8 3/4"
Second Floor
1008' - 4 5/8"
Roof
1016' - 5 3/4"
Basement
988' - 0"
T.O. Footing
987' - 8 1/2"
Top of Foundation
993' - 8 1/2"
First Floor Clg.
1006' - 9 7/8"
Basement Clg.
996' - 2"
Roof Peak
1029' - 3"3' - 6"8' - 2"9' - 5 1/8"8' - 1 1/8"12"
24"
24"
24"
28' - 0"15' - 0"17 RISERS10' - 7 7/8"16 RISERS9' - 8 3/4"36"51 1/16"14 5/8"51 1/16"52 5/8"15 1/16"52 5/8"7 1/2"11' - 0"
GAP
14 1/2"25' - 9 1/4"6' - 0"1' - 10 1/8"11' - 10 7/8"12' - 0 1/4"14"
12"
15' - 0 1/2"
11"7 5/16"11"7 1/2"8" BUILD-OUTGAME ROOM
STAIRCASE
GREAT
ROOM
PKT.
OFFICE
BEDROOM #3LOFT
ROOF TRUSSES
PER MFG. SPEC.
GRADE MUST BE
MINIMUM OF 6"
BELOW TOP OF
FOUNDATION WALL
B.O. FOOTING @ MIN.
42" BELOW GRADE
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB OVER
POLY/VAPOR BARRIER OVER
SAND BED GRANULAR FILL
3/4" SUBFLOOR
18" FLOOR TRUSSES @ 19.2" O.C.
BEAM DROPPED
PER MFG. SPEC.
BEAM
FLUSH
PER MFG.
SPEC.
BEAM
FLUSH
PER MFG.
SPEC.
EXPOSED
TREADS &
RISERS
TYPICAL STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
(4) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
TYPICAL STAIRCASE
LANDING CONSTRUCTION:
2-2x8 HEADER
3/4" PLYWOOD
BACKING
2x8 JOISTS @ 16" O.C.
3/4" PLYWOOD
3/4" SUBFLOOR
14" FLOOR TRUSSES @ 19.2" O.C.
RECTANGLE
STEEL TUBE
STRINGER
SUPPORT WOOD
WRAPPED
SUSPENDED STAIRCASE CONSTRUCTION:
6'-10" MINIMUM HEADROOM
RECTANGLE ST'L TUBE STRINGER, WOOD
WRAPPED w/1-1/8" x 11-1/4"
PARTICLE BOARD TREADS
PROVIDE 34"-36" HGT HANDRAILS
& GUARDS RAILS PER CODE
STAIRCASE LANDING
3/4" SUBFLOOR
18" FLOOR TRUSSES @
19.2" O.C.9' - 1 1/8"4"12"24"24"24"24"12"12"
24"30"30"20 3/16"
24"12"24"24"12"12"24"
12"18"24"24"24"24"12"12"6"
24"
24"12' - 0"26' - 6"
6"
7' - 0"
24"24"12"36"5' - 0"16' - 0"
24"38 1/2"10" / 12"10" / 12"6" / 12"14" / 12"14" / 12"14" / 12"14" / 12"14" / 12"ENGINEERING ROOF TRUSSES PER MFG. SPEC.
MANUFACTURE WILL PROVIDE ALL ENGINEERING
DRAWING AND SPECIFICS
OVERHANG DIMENSIONS ARE TO FACE OF
FRAMING
ICE AND WATER ALL ADJOINING ROOFS
NOTE:RIDGE VENT10:12 SLOPE6:12 SLOPE
SADDLE14:12 SLOPE 14:12 SLOPE14:12 SLOPE14:12 SLOPE
RIDGE VENT
14" / 12"
14" / 12"
14" / 12"
14" / 12"
14" / 12"
7" / 12"
14" / 12"DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:45:00AM08 Cross SectionsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044 1/4" = 1'-0"3 Cross Section - Front Porch/Laundry
1/4" = 1'-0"2 Cross Section - Staircase
4 Great Room Ceiling
331 SF
MECHANICAL ROOM
267 SF
UNFINISHED
STORAGE
1347 SF
LOWER LEVEL
858 SF
GARAGE
1969 SF
MAIN LEVEL
177 SF
DECK
80 SF
FRONT
PORCH
1102 SF
UPPER LEVEL
116 SF
STAIRCASE
3' - 6"8' - 2"18 3/4"9' - 1 1/8"18 3/4"E.H.25 11/16"20 11/16"
24"UPPER LEVEL WINDOW HEADER HEIGHT84"MAIN LEVEL WINDOW HEADER HEIGHT96"LOWER LEVEL WINDOW HEADER HEIGHT84"14"
12"
14"
12"ROOF, CEILING & EAVE
CONSTRUCTION:
WALL
CONSTRUCTION:
FOUNDATION WALL &
BASEMENT SLAB
CONSTRUCTION:
MAIN LEVEL
CONSTRUCTION:
UPPER LEVEL
CONSTRUCTION:
ARCHITECTURAL GRADE ASPHALT
SHINGLES
#15FELT & ICE & WATER SHIELD (6'-0")
1/2" OSB SHEATHING w/STEEL CLIPS
TRUSSES @ 24" O.C. (PER MFG. SPEC.)
BAFFLES w/1" AIR SPACE
2X4 LOOKOUTS
2X8 SUB FASCIA w/ 8" COMPOSITE FASCIA
COMPOSITE VENTED SOFFITS
COMPOSITE FRIEZE BOARDS
R-50 BLOWN INSULATION
POLY VAPOR BARRIER
5/8" GYP. BRD. CEILING
3/4" T&G PLYWOOD SUBFLOOR
GLUED & SCREWED
18" FLOOR TRUSSES @ 19.2" O.C.
(FLOOR SYSTEM DESIGNER TO
VERIFY SIZE & SPACING BASED
ON SPANS)
5/8" GYP. BRD. ON CEILING
SPRAY INSULATE RIMS (R-21)
SIDING PER ELEVATION
HOUSE WRAP (WRAP
WINDOWS PER MFG. SPEC.)
1/2" OSB SHEATHING
2X6 STUDS @16" O.C.
DBL. TOP PLATE
R-21 WALL INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYP. BRD.
2X6 SOLE PLATE
ALL DETAILS TO CONFORM W/
ENERGY CODE
3/4" T&G PLYWOOD SUBFLOOR
GLUED & SCREWED
18" FLOOR TRUSSES @ 19.2" O.C.
(FLOOR SYSTEM DESIGNER TO
VERIFY SIZE & SPACING BASED ON
SPANS)
FLASHING UNDER SILLS & STOOPS
TREATED 2X6 SILL PLATE w/
SEALER
1/2" ANCHOR BOLTS @ 6' O.C. & 1'
FROM CORNERS
5/8" GYP. BRD. ON CEILING
SPRAY INSULATE RIMS (R-21)
WATERPROOFING
EXTERIOR THERMAL WALL:
2" RIGID INSULATION (R-10) APPLIED TO
EXTERIOR, PROVIDE FLASHING TO
COVER EXPOSED INSULATION
POURED CONC. WALL PER PLAN
REINFORCE WALLS PER CODE AND
ENGINEER'S SPECIFICATIONS
20" X 8" CONTINUOUS CONC. FOOTING
UNLESS OTHERWISE NOTED
4" CONC. SLAB
VAPOR/MOISTURE BARRIER PER IRC
SECTION 506 EXTENDING UP THE WALL
AND SEALED TO FOUNDATION WALL
4" SAND/AGGREGATE FILL
INTERIOR & EXTERIOR 4"
DIA. PERFORATED DRAIN
TILE PIPED TO SUMP
BASKET
INTERIOR THERMAL WALL:
1" RIGID INSULATION (R-5)
2x4 STUDS @ 16" O.C.
2x4 TRD. PLATE
1/2" GYP BD.8' - 1 1/8"8' - 4"13"42"66"2 1/4"48"9' - 3 1/2"66"FRAMING
30"9' - 2 1/4"FRAMING
13 1/2"
FRAMING
13 1/2"
FRAMING
48"9 1/4"9 1/4"5 1/4"
24"
FRAMING
37 1/2"
FRAMING GAP
10 1/2"7' - 5"16 7/16"22 3/8"FRAMING38 13/16"FINISHED
30"
60.90°
BEAM PER MFG SPEC. FLUSH
ROOF TRUSSES
PER MFG. SPEC.6x6 STRUCTURAL POST14"
12"
COLUMN CONSTRUCTION:
2X10 TOP/BOTTOM COLLAR
3/4" COMPOSITE WRAP
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL POST
COLUMN BASE:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
6X6 TRD. STRUCTURAL
POST
COLUMN FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
53"x29"x72" POURED CONC.
PIER ON
60"x41"x8" CONC. FOOTING
REBAR PER CODEWING WALL FOUNDATION:
(SEE FOUNDATION PLAN FOR
FULL DETAILS)
29"x30"x66" POURED CONC.
PIER ON
60"x42"x8" CONC. FOOTING
REBAR PER CODE
WING WALL
CONSTRUCTION:
2-1/4" STONE CAP
CULTURED STONE
GROUT JOINTS
1/2" TRD. PLYWOOD
2X4 FRAMED BOX
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended
that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2019. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.5/8/2019 9:45:01AM09 Square Footage CalculationsSDC - Gliniecki - CD -REV5- SMGliniecki ResidenceSD Custom Homes750 Main StreetSuite #223Mendota Heights, MN 551182.20.2019SMLake Marion Parcel B199th StreetLakeville, MN 55044LOWER LEVEL:
SQUARE FOOTAGE
CALCULATIONS
1347 SQ. FT. LOWER LEVEL
331 SQ. FT. MECHANICAL ROOM
267 SQ. FT. UNFINISHED STORAGE
1969 SQ. FT. MAIN LEVEL
858 SQ. FT. GARAGE
177 SQ. FT. DECK
80 SQ. FT. FRONT PORCH
1102 SQ. FT. UPPER LEVEL
116 SQ. FT. STAIRCASE
4418 SQ. FT. FINISHED TOTAL
(DOES NOT INCLUDE UPPER LEVEL
STAIRCASE)
GENERAL NOTES
1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C.
2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS
OTHERWISE NOTED)
3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING
4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR.
5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD
6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND
50% AT SOFFIT-MIN
7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILER UNLESS OTHERWISE
NOTED. UNDERCUT MIN 1"
8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER.
9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF
A DOORWAY SHALL BE TEMPERED GLASS
10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR
EQUIVALENT
11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR
12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES
13. 1/2" AIR SPACE ON EACH SIDE OF MICRO-LAM BEAM & MIN 3" BEARING ON CONCRETE
14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE
TO PASS THROUGH
15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE
16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE
TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY
17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS
18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER
SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE
19. PROVIDE DRAFT STOPS PER UBC 708.3
20. FIRE BLOCK ALL CHASES AT EACH FLOOR-CEILING ASSEMBLY OR AT 10' MAX
INTERVALS
21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE
22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD
23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS
24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED
MATERIALS
25. BLOCK PATIO DOORS WITHOUT A DECK
26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC
27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES
28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE
ROOMS
29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE
STAIRS
30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN
REQUIRED (IMC703)
31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED
32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE
62-2001 6.1)
33. DRYER VENT TO THE EXTERIOR- INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER
OPENINGS: (IMC504.4, 401.52 AND 604.1)
34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD
OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS.
CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE
VAPOR BARRIER (R307)
35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE.
ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL
36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH
OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A
TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE
REQUIRED AT MIN 4" O.C.
37. 4-MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING.
FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED
38. WIND-WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING
INSULATION DAM @ CEILING CHANGES
39. WEATHER-RESISTIVE BARRIER-i.e. BUILDING WRAP TABLE R703.4
40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO
AT LEAST R-3
41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE
WEATHERED-STRIPPED AND INSULATED.
42. NEW WOOD-BURNING FIREPLACES WILL HAVE TIGHT-FITTING FLUE DAMPERS AND
OUTDOOR COMBUSTION AIR.
43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6'
ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE
FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4",
WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL
DEVICES.
44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED
WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH
SLEEPING AREA OR BEDROOM.
45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi.
46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL
MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES.
EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES
C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR
ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE
LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10".
47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY
ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND
LATERAL LOADS.
48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE
INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL
COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A
MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER-RESISTIVE
BARRIER MUST LAP OVER THE ATTACHMENT FLANGE.
49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS
1" = 10'-0"1 Basement
1" = 10'-0"2 First Floor
1" = 10'-0"3 Second Floor
1/2" = 1'-0"4 Detail - Typical Wall Section
3/8" = 1'-0"5 Detail - Column Section View
FINISHED TOTAL:
UPPER LEVEL:
MAIN LEVEL:
ALL BEAMS BYOTHERSH2H1H1H1H1H1H1H1H1H1K1K1L2L1L1L1L1L1M2M1M1M1M1M2W2W1W1W1W1W1T2T1T1T1T1T1T1N3Q1J1J1J1N6N5N4N4N2N1S3S2S1S1S1S1S1R1K2S4U1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z1Z3Z2Z2Z2Z2Z2X1P2P1P1P1P1P1P1P1P1P1P1P1P4P3P3P3P3P3P11P10P10P10P10P10P10P9P8P7P6P5P523-00-008-00-00 6-00-00 10-00-00 6-00-00 4-00-00 4-00-0061-00-0014-00-0019-00-0015-00-00 13-00-0061-00-001-06-0012-00-0023-00-0011-00-0034-00-0081-06-001-06-0012-00-0024-00-008-00-00 14-00-00 14-00-00 6-00-002-00-0081-06-00G3G1G1G1G1G1G2A2A1A1A1A1A1A1E3E2E1E4B2B3B1B1B1D7D6D6C1C2C2C2C2D5D4D3D2D1V1V1V1V1V1V2V3V4V5V6Customer: Dakota County LumberJob Number: 308382-AHome Owner: SD / GLINECKI RESJob Name: RoofSite Address: 199 TH ST Sales Rep: John HummelCity, ST, ZIP: LAKEVILLE MN Designer: <<UN ASSIGNED>>2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/16/2019Version: 8.3.0.234
FLUSH BMBY OTHERSF9F11F12F8F10F9F1F1F1F1F1F1F1F1F2F2F2F2F2F2F3F3F3F3F3F3F4F5F5F5F5F5F5F5F5F5F6F6F6F6F6F7F7F723-00-0010-06-0023-06-00 4-00-0061-00-0014-00-0019-00-0015-00-00 13-00-0061-00-0011-00-0034-00-0045-00-001-00-008-00-00 14-00-00 14-00-00 6-00-002-00-0045-00-0020-08-1211-00-0810-071-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-03Customer: Dakota County LumberJob Number: 308382-BHome Owner: SD / GLINECKI RESJob Name: FloorSite Address: 199 TH ST Sales Rep: John HummelCity, ST, ZIP: LAKEVILLE MN Designer: <<UN ASSIGNED>>2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/16/2019Version: 8.3.0.234
ALL BEAMS BYOTHERSFF9FF2FF7FF1FF1FF1FF1FF1FF1FF1FF1FF3FF3FF3FF3FF3FF3FF4FF4FF4FF4FF5FF5FF6FF8FF8FF8FF8FF8FF8FF8FF8FF8FF5FF5FF5FF5FF5FF5FF5FF5FF5FF6FF6FF6FF6FF6FF6FF6FF6FF6FF5FF323-00-008-00-00 6-00-00 10-00-00 6-00-00 4-00-00 4-00-0061-00-0014-00-0019-00-0015-00-00 13-00-0061-00-001-06-0012-00-0023-00-0011-00-0034-00-0081-06-001-06-0012-00-0024-00-008-00-00 14-00-00 14-00-00 6-00-002-00-0081-06-00Customer: Dakota County LumberJob Number: 308382-BHome Owner: SD / GLINECKI RESJob Name: FloorSite Address: 199 TH ST Sales Rep: John HummelCity, ST, ZIP: LAKEVILLE MN Designer: <<UN ASSIGNED>>2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/16/2019Version: 8.3.0.234
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Apr-14 12:08:12
Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1
G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Load Short Form Apr 14, 2019Date:Entire House By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:
Lake Marion Parcial B,199th St, Lakeville, mn
Design Information
InfiltrationClgHtg
SimplifiedMethod88-15Outside db (°F)
AverageConstruction quality7572Inside db (°F)
0Fireplaces1387Design TD (°F)
M-Daily range
5030Inside humidity (%)
2834Moisture difference (gr/lb)
HEATING EQUIPMENT COOLING EQUIPMENT
Make Lennox Make Lennox
Trade LENNOX Trade LENNOX
Model ML193UH110XP60C-*Cond XC16-060-230-05
AHRI ref 4792833 Coil C33-62C+EL195UH110XE60C*+TDR+TXV
AHRI ref 6564076
Efficiency 93 AFUE Efficiency 12.2 EER, 15.5 SEER
Heating input Btuh110000 Sensible cooling Btuh40250
Heating output Btuh104000 Latent cooling Btuh17250
Temperature rise °F51 Total cooling Btuh57500
Actual air flow cfm1917 Actual air flow cfm1917
Air flow factor cfm/Btuh0.024 Air flow factor cfm/Btuh0.047
Static pressure in H2O0 Static pressure in H2O0
Space thermostat Load sensible heat ratio 0.87
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft²)(Btuh)(Btuh)(cfm)(cfm)
below Grade 980 8209 1976 199 93
walk out 1023 17801 7955 432 375
main floor 1998 33168 21675 805 1022
upper level 1217 19836 9035 481 426
Entire House 5218 79014 40640 1917 1917
Other equip loads 4986 2445
Equip. @ 0.93 RSM 39983
Latent cooling 6660
TOTALS 5218 84000 46643 1917 1917
Bold/italic values have been manually overridden
2019-Apr-14 12:08:12
Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Building Analysis Apr 14, 2019Date:Entire House By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US 1387Design TD (°F)ft837Elevation:5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Heating
Walls
Glazing
OtherCeilingsFloors
Infiltration
Ventilation
% of loadBtuhBtuh/ft²Component
24.7207454.3Walls 28.62400529.5Glazing 1.7142533.9Doors 4.638351.9Ceilings 6.050122.52.5Floors 28.6239924.9Infiltration 00Ducts00Piping00Humidification5.94986Ventilation0Adjustments100.084000Total
Cooling
Walls
Glazing
OtherCeilings
Infiltration
Internal GainsVentilation
% of loadBtuhBtuh/ft²Component
7.331550.6Walls 66.92880635.4Glazing 1.04109.8Doors 5.021381.1Ceilings 000Floors4.218130.4Infiltration 00Ducts5.72445Ventilation10.04320Internal gains 00Blower0Adjustments100.043085Total
Latent Cooling Load = 6660 BtuhOverall U-value = 0.065 Btuh/ft²-°F
Data entries checked.
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Component Constructions Apr 14, 2019Date:Entire House By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15
ins, 10" thk
490.1117973.9515.00.042455n
470.1117283.9515.00.042438e
30.111283.9515.00.04233s
003743.5615.00.042105w
990.1040283.9115.00.0421030all
IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins,
5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
6050.8033114.3520.00.050761n
7660.8041914.3520.00.050964e
8730.8047744.3520.00.0501098s
8120.8044404.3520.00.0501021w
30550.80167174.3520.00.0503843all
Partitions
(none)
Windows4A5-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap,
1/8" thk; 6.67 ft head ht
8011.927540.900.4707n
121634.9142340.900.47035w
125834.9147240.900.47036w
255332.9317040.900.47078all
IECC 2012 Minimum: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr
innr, 1/2" gap, 1/4" thk; NFRC rated (SHGC=0.32); 6.67 ft head ht
33510.192127.800.32033n
49923.858527.800.32021e
563333.9462027.800.320166e
199219.0292327.800.320105s
387033.9317427.800.320114w
941033.9771727.800.320277w
2173930.41994027.800.320716all
10D-v: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2"
gap, 1/4" thk; 6.67 ft head ht
53125.389542.600.49021w
Doors11D0: Door, wd sc type 2059.7571333.900.39021e
2059.7571333.900.39021s
4109.75142533.900.39042all
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 2G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Ceilings16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 1/2"
gypsum board int fnsh
21381.0738351.9144.00.0222004
Floors
21A-32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet flr fnsh 017061.7400.020980 0
22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10
edge ins, carpet flr fnsh
00330530.910.00.355107
22D-5cpm: Bg floor, heavy dry or light damp soil, full ext ins cov, on
grade depth, r-3 edge ins, r-10 ins, carpet flr fnsh
00238.55.00.4420
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 3G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Component Constructions Apr 14, 2019Date:below Grade By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
15B-15sfc-8: Bg wall, heavy dry or light damp soil, concrete wall, r-15
ins, 10" thk
490.1117973.9515.00.042455n
470.1117283.9515.00.042438e
30.111283.9515.00.04233s
003743.5615.00.042105w
990.1040283.9115.00.0421030all
Partitions
(none)
Windows
4A5-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap,
1/8" thk; 6.67 ft head ht
121634.9142340.900.47035w
Doors(none)
Ceilings16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 1/2"
gypsum board int fnsh
31.0751.9144.00.0223
Floors
21A-32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet flr fnsh 017061.7400.020980 0
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 4G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Component Constructions Apr 14, 2019Date:walk out By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins,
5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
1390.807614.3520.00.050175e
3190.8017474.3520.00.050402s
2680.8014684.3520.00.050338w
7270.8039764.3520.00.050914all
Partitions(none)
Windows
4A5-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap,
1/8" thk; 6.67 ft head ht
125834.9147240.900.47036w
4A5-2ovd: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2"
gap, 1/4" thk; NFRC rated (SHGC=0.32); 6.67 ft head ht
142633.9116927.800.32042w
122233.9100227.800.32036w
264833.9217227.800.32078all
10D-v: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2"
gap, 1/4" thk; 6.67 ft head ht
53125.389542.600.49021w
Doors11D0: Door, wd sc type 2059.7571333.900.39021s
Ceilings
16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 1/2"
gypsum board int fnsh
41.0761.9144.00.0223
Floors
22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10
edge ins, carpet flr fnsh
00330530.910.00.355107
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 5G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Component Constructions Apr 14, 2019Date:main floor By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins,
5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
3360.8018394.3520.00.050423n
3880.8021234.3520.00.050488e
2880.8015754.3520.00.050362s
2900.8015894.3520.00.050365w
13020.8071264.3520.00.0501638all
Partitions
(none)
Windows
4A5-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap,
1/8" thk; 6.67 ft head ht
8011.927540.900.4707n
IECC 2012 Minimum: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr
innr, 1/2" gap, 1/4" thk; NFRC rated (SHGC=0.32); 6.67 ft head ht
25810.170827.800.32025n
49923.858527.800.32021e
280133.9229727.800.32083e
176419.0258927.800.32093s
244433.9200427.800.32072w
594733.9487827.800.320175w
1371329.21306127.800.320469all
Doors
11D0: Door, wd sc type 2059.7571333.900.39021e
Ceilings
16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 1/2"
gypsum board int fnsh
8331.0714941.9144.00.022781
Floors(none)
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 6G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Component Constructions Apr 14, 2019Date:upper level By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F)
SimplifiedMethod)M(19-Daily range (°F)
AverageConstruction quality72-Wet bulb (°F)
0Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
IECC2012 frame zone 6: Frm wall, vnl ext, 1/2" wood shth, r-20 cav ins,
5/8" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
2690.8014724.3520.00.050338n
2390.8013074.3520.00.050301e
2660.8014534.3520.00.050334s
2530.8013834.3520.00.050318w
10260.8056154.3520.00.0501291all
Partitions
(none)
Windows
IECC 2012 Minimum: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr
innr, 1/2" gap, 1/4" thk; NFRC rated (SHGC=0.32); 6.67 ft head ht
7810.121327.800.3208n
283333.9232327.800.32083e
22819.033427.800.32012s
224033.9183727.800.32066w
537831.8470827.800.320169all
Doors(none)
Ceilings
16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 1/2"
gypsum board int fnsh
12991.0723301.9144.00.0221217
Floors
22D-5cpm: Bg floor, heavy dry or light damp soil, full ext ins cov, on
grade depth, r-3 edge ins, r-10 ins, carpet flr fnsh
00238.55.00.4420
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Apr-14 12:08:12Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Project Summary Apr 14, 2019Date:Entire House By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:Lake Marion Parcial B,199th St, Lakeville, mn
Notes:
Design Information
Minneapolis/St. Paul, MN, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F-15 Outside db °F88Inside db °F72 Inside db °F75Design TD °F87 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb28
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh79014 Structure Btuh40640DuctsBtuh0DuctsBtuh0Central vent (SER=70% 179 cfm)Btuh4986 Central vent (SER=0% 179 cfm)2445 BtuhHeat recovery Heat recoveryHumidificationBtuh0Blower Btuh0PipingBtuh0Equipment load Btuh84000 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh39983
Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh3295DuctsBtuh0Central vent (179 cfm)Btuh3365CoolingHeatingHeat recovery52185218Area (ft²)Equipment latent load Btuh66604190641906Volume (ft³)Air changes/hour 0.190.37 Equipment Total Load (Sen+Lat)Btuh46643Equiv. AVF (cfm)133258 Req. total capacity at 0.70 SHR ton4.8
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make LennoxTradeLENNOXTradeLENNOXModelML193UH110XP60C-*Cond XC16-060-230-05AHRI ref 4792833 Coil C33-62C+EL195UH110XE60C*+TDR+TXVAHRI ref 6564076Efficiency93 AFUE Efficiency 12.2 EER, 15.5 SEERHeating input Btuh110000 Sensible cooling Btuh40250Heating output Btuh104000 Latent cooling Btuh17250Temperature rise °F51 Total cooling Btuh57500Actual air flow cfm1917 Actual air flow cfm1917Air flow factor cfm/Btuh0.024 Air flow factor cfm/Btuh0.047Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.87
Bold/italic values have been manually overridden
2019-Apr-14 12:08:13
Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1
G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:AED Assessment Apr 14, 2019Date:Entire House By:
Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
Project Information
Gliniecki Residence, Binder HeatingFor:
Lake Marion Parcial B,199th St, Lakeville, mn
Design Conditions
Location:CoolingHeatingIndoor:
7572Indoor temperature (°F)Minneapolis/St. Paul, MN, US
1387Design TD (°F)ft837Elevation:
5030Relative humidity (%)°N45Latitude:Outdoor:28.534.0Moisture difference (gr/lb)CoolingHeating
Infiltration:88-15Dry bulb (°F))M(19-Daily range (°F)
72-Wet bulb (°F)7.515.0Wind speed (mph)
Test for Adequate Exposure Diversity
Hourly Glazing Load
Hourly Average AED limitGlazing load (Btuh)Hour of Day
0
5,000
10,000
15,000
20,000
25,000
30,000
35,000
8 9 10 11 12 13 14 15 16 17 18 19 20
Maximum hourly glazing load exceeds average by 47.7%.
House does not have adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 3983 Btuh (PFG - 1.3*AFG)
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Apr-14 12:08:13Right-Suite® Universal 2018 18.0.10 RSU16575 Page 1G:\binder heating\gliniecki residence.rup Calc = MJ8 Front Door faces: SW
Job:Right-J® Worksheet Apr 14, 2019Date:Entire House By:Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
1 Room name Entire House below Grade
2 Exposed wall 609.5 ft 106.5 ft3Room height 9.5 ft 10.0 heat/coolft
4 Room dimensions ft980.3x1.0
5 Room area 5218.3 ft²980.3 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 15B-15sfc-815B-15sfc-8 0.0590.059 nn 3.953.95 0.110.11 455 455 1797 49 455 455 1797 49.WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 nn 4.354.35 0.800.80 801 761 3311 605 0 0 0 0.GG 4A5-2ov4A5-2ov 0.4700.470 nn 40.8940.89 11.8611.86 7 0 275 80 0 0 0 0
.GG IECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 nn 27.8427.84 10.1310.13 33 0 921 335 0 0 0 0
11 WW 15B-15sfc-815B-15sfc-8 0.0590.059 ee 3.953.95 0.110.11 438 438 1728 47 438 438 1728 47
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ee 4.354.35 0.800.80 1172 964 4191 766 0 0 0 0
GG 10D-v10D-v 0.3200.320 ee 27.8427.84 23.7623.76 21 0 585 499 0 0 0 0GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ee 27.8427.84 33.9533.95 166 0 4620 5633 0 0 0 0
DD 11D011D0 0.3900.390 ee 33.9333.93 9.759.75 21 21 713 205 0 0 0 0WW15B-15sfc-815B-15sfc-8 0.0590.059 ss 3.953.95 0.110.11 33 33 128 3 33 33 128 3
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ss 4.354.35 0.800.80 1224 1098 4774 873 0 0 0 0GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ss 27.8427.84 18.9718.97 105 0 2923 1992 0 0 0 0DD11D011D00.3900.390 ss 33.9333.93 9.759.75 21 21 713 205 0 0 0 0
WW 15B-15sfc-815B-15sfc-8 0.0590.059 ww 3.563.56 0.000.00 140 105 374 0 140 105 374 0GG4A5-2ov4A5-2ov 0.4700.470 ww 40.8940.89 34.9334.93 35 0 1423 1216 35 0 1423 1216
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ww 4.354.35 0.800.80 1469 1021 4440 812 0 0 0 0
GG 10D-v10D-v 0.4900.490 ww 42.6342.63 25.2925.29 21 0 895 531 0 0 0 0
GG 4A5-2ov4A5-2ov 0.4700.470 ww 40.8940.89 34.9334.93 36 0 1472 1258 0 0 0 0
GG 4A5-2ovd4A5-2ovd 0.3200.320 ww 27.8427.84 33.9533.95 114 0 3174 3870 0 0 0 0GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ww 27.8427.84 33.9533.95 277 0 7717 9410 0 0 0 0CC16B-44ad16B-44ad 0.0220.022 --1.911.91 1.071.07 2004 2004 3835 2138 3 3 5 3
FF 21A-32c21A-32c 0.0200.020 --1.741.74 0.000.00 980 980 1706 0 980 980 1706 0FF22B-10cpm22B-10cpm 0.3550.355 --30.8830.88 0.000.00 1023 107 3305 0 0 0 0 0
FF 22D-5cpm22D-5cpm 0.4420.442 --38.4538.45 0.000.00 0 0 2 0 0 0 0 0
6 c) AED excursion 3983 579
Envelope loss/gain 55023 34508 7162 1897
12 a)Infiltration 23992 1813 1048 79
b)Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 4 920 0 0
Appliances/other 3400 0
Subtotal (lines 6 to 13)79014 40640 8209 1976
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal790144064082091976
15 Duct loads 0%0%0 0 -0%0%0 0
Total room load 79014 40640 8209 1976
Air required (cfm)Air required (cfm)1917 1917 199 93
Job:Right-J® Worksheet Apr 14, 2019Date:Entire House By:Anthony Ledo
St. Paul, Mn 55105 Phone: 763-229-4252
1 Room name walk out main floor
2 Exposed wall 107.0 ft 213.5 ft3Room height 10.0 heat/coolft 10.0 heat/coolft
4 Room dimensions ft1023.2x1.0 ft1997.5x1.0
5 Room area 1023.2 ft²1997.5 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 15B-15sfc-815B-15sfc-8 0.0590.059 nn 3.953.95 0.110.11 0 0 0 0 0 0 0 0.WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 nn 4.354.35 0.800.80 0 0 0 0 455 423 1839 336.GG 4A5-2ov4A5-2ov 0.4700.470 nn 40.8940.89 11.8611.86 0 0 0 0 7 0 275 80
.GG IECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 nn 27.8427.84 10.1310.13 0 0 0 0 25 0 708 258
11 WW 15B-15sfc-815B-15sfc-8 0.0590.059 ee 3.953.95 0.110.11 0 0 0 0 0 0 0 0
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ee 4.354.35 0.800.80 175 175 761 139 613 488 2123 388
GG 10D-v10D-v 0.3200.320 ee 27.8427.84 23.7623.76 0 0 0 0 21 0 585 499GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ee 27.8427.84 33.9533.95 0 0 0 0 83 0 2297 2801
DD 11D011D0 0.3900.390 ee 33.9333.93 9.759.75 0 0 0 0 21 21 713 205WW15B-15sfc-815B-15sfc-8 0.0590.059 ss 3.953.95 0.110.11 0 0 0 0 0 0 0 0
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ss 4.354.35 0.800.80 423 402 1747 319 455 362 1575 288GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ss 27.8427.84 18.9718.97 0 0 0 0 93 0 2589 1764DD11D011D00.3900.390 ss 33.9333.93 9.759.75 21 21 713 205 0 0 0 0
WW 15B-15sfc-815B-15sfc-8 0.0590.059 ww 3.563.56 0.000.00 0 0 0 0 0 0 0 0GG4A5-2ov4A5-2ov 0.4700.470 ww 40.8940.89 34.9334.93 0 0 0 0 0 0 0 0
WW IECC2012 frame zone 0.050IECC2012 frame zone 0.050 ww 4.354.35 0.800.80 473 338 1468 268 613 365 1589 290
GG 10D-v10D-v 0.4900.490 ww 42.6342.63 25.2925.29 21 0 895 531 0 0 0 0
GG 4A5-2ov4A5-2ov 0.4700.470 ww 40.8940.89 34.9334.93 36 0 1472 1258 0 0 0 0
GG 4A5-2ovd4A5-2ovd 0.3200.320 ww 27.8427.84 33.9533.95 42 0 1169 1426 72 0 2004 2444GGIECC 2012 Minimum 0.320IECC 2012 Minimum 0.320 ww 27.8427.84 33.9533.95 36 0 1002 1222 175 0 4878 5947CC16B-44ad16B-44ad 0.0220.022 --1.911.91 1.071.07 3 3 6 4 781 781 1494 833
FF 21A-32c21A-32c 0.0200.020 --1.741.74 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --30.8830.88 0.000.00 1023 107 3305 0 0 0 0 0
FF 22D-5cpm22D-5cpm 0.4420.442 --38.4538.45 0.000.00 0 0 0 0 0 0 0 0
Job #:
Performed for:
Gliniecki Residence
Lake Marion Parcial B,199th St
Lakeville, mn
Anthony Ledo
St. Paul, Mn 55105
Phone: 763-229-4252
Scale: 1 : 102
Page 1
Right-Suite® Universal 2018
18.0.10 RSU16575
2019-Apr-14 12:09:30
... heating\gliniecki residence.rup
N
Level 1
upper level
160 cfm
160 cfm
160 cfm
Job #:
Performed for:
Gliniecki Residence
Lake Marion Parcial B,199th St
Lakeville, mn
Anthony Ledo
St. Paul, Mn 55105
Phone: 763-229-4252
Scale: 1 : 102
Page 2
Ri ght-Suite® Universal 2018
18.0.10 RSU16575
2019-Apr-14 12:09:30
... heating\gliniecki residence.rup
N
Main floor
main floor
170 cfm170 cfm
170 cfm
170 cfm170 cfm170 cfm
Job #:
Performed for:
Gliniecki Residence
Lake Marion Parcial B,199th St
Lakeville, mn
Anthony Ledo
St. Paul, Mn 55105
Phone: 763-229-4252
Scale: 1 : 102
Page 3
Ri ght-Suite® Universal 2018
18.0.10 RSU16575
2019-Apr-14 12:09:30
... heating\gliniecki residence.rup
N
lower level
below Grade
walk out
100 cfm
144 cfm
1917 cfm
144 cfm144 cfm
100 cfm
Date Certificate Posted
X Passive (No Fan)Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
100,000 Capacity
in Gallons:
Other, describe:
AFUE or
HSPF%
95
Cfm's
" round duct OR
" metal duct
Not required per mech. code
X Passive
X Low: Other, describe:
Low:
Location of fan(s), describe: 150 Cfm's
6" " round duct OR
" metal duct
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
46643
Below Entire Slab Rigid, Extruded PolystyrenePer R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
MN License Number
LAKEVILLEGLINIECKI, 199TH LAKEVILLE
MECH ROOM
82Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
84123
Heating Gain Cooling Load
Ceiling, flat
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not Applicable Appliances Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell
Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness:
Building envelope air tightness:
Rim Joist (1st Floor)
4TTR3060 Model
Heating System
Natural Gas
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency
13
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Residential Load Calculation
SEER
/EER
192
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
TRANE
TUH1C100A960
Heating Loss
Manufacturer TRANE
Output
in Tons:
5
Builders Associaton of Minnesota version 101014