Loading...
HomeMy WebLinkAboutLA171906 17398 Eastwood Ave Permit packRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 08/07/2019dmathews UFER Ground -Min. 15" clearance to anyobstruction from center of W.C., 24" in front(typ). R-4 on pipe in attic Builders Associaton of Minnesota version 101014 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17398 Eastwood Lakeville Name of Residential Contractor MN License NumberDistinctive Design Build THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here Below Entire Slab X Foundation Wall R-15 X Interior R5 + R10 Exterior Perimeter of Slab on Grade X Rim Joist (1st Floor)R-20 X Interior Rim Joist (2nd Floor+)X Wall R-20 X Ceiling, flat R-49 X Ceiling, vaulted R-49 X Bay Windows or cantilevered areas R-30 X Floors over unconditioned area R-30 X Describe other insulated areas Building envelope air tightness:Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.32 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.32 8 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic WaterHeater Cooling System Not required per mech. code Fuel Type Nat Gas Nat Gas Elect X Passive Manufacturer Bryant AOSmith Bryant Powered Model 912SC30040S17 GPVL-50 BA13NA024 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS:40,000 Capacity in Gallons:50 Output in Tons:2 ton Other, describe: Efficiency AFUE or HSPF%92%0.7 SEER /EER 13 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 4" Flexible duct to mech room 35,276 18,027 22,954 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfms:Low: High:Other, describe: X Energy Recover Ventilator (ERV) Capacity in cfms:Low: 50%=63 cfm High:100%=126 CFM Location of duct or system: Balanced Ventilation capacity in cfms:126 cfm @ 100% SETTING Mech Room Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms:63 CFM 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms:125 CFM " metal duct 07/27/19 X KP