Loading...
HomeMy WebLinkAboutLA172572 18892 Houston Way Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014CAAAABBBBCCCCDDDDEEEE6:126:128:124:126:128:128:1232' RIDGE VENT10' RIDGE VENT 9' RIDGE VENTROOF PLAN1/8"=1'-0"D128STEEL PANEL OVERHEAD DOORADDRESS NUMBER6:12 PITCH6:12 PITCHF1'-0"1'-4"10 1/8" HEEL8"8"4:12 PITCHFREDWOOD 'C' FRONTD2x6 CAP2x6 BASE8x8 REALWOOD COLUMN4x4 REALWOODANGLED BRACKET1'-9"1'-9"45°DETAIL1/4"=1'-0"PORCH COLUMNICE & WATERALUMINUM FLASHINGBEHIND STOOP5 3/4"5-3/4" FROM TOP OF THRESHOLDHARDBOARD TRIMHARD BOARD SIDINGHARD BOARD SIDING2-SIDED OUTSIDE CORNER2-3/4" .96"3-1/2"SHEATHINGHDBD TRIM 1-SIDED OUTSIDE CORNER3-1/2"HARD BOARD SIDINGVINYL SIDING"J" CHANNELHARDBOARD TRIMAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM5" TRIM5" TRIM1 1/2"3 1/2" TRIM 3 1/2" TRIMXXXXX8" TRIMF1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72725475-C-3.0REDWOODDRAWN: 11-19-2015-AWPERMIT/CONSTRUCT:7-29-19-MKSPEC HOMECUST:HEARTLAND COTTAGERAIN DIVERTERGHGREFAVINYL LAP SIDINGPRODUCTCBD5/4X6 CEMENT BD. TRIMREFMATERIAL LEGENDECEMENT BD. SIDINGPRODUCTGFHCEMENT BD. SHAKES5/4X8 CEMENT BD TRIMNOT USEDNOT USEDC.B. BOARD-N-BATTENE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTH42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BELEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"7 7/16" HEEL 1'-4"126A6:12 PITCH1'-0"1'-0"ASPHALT SHINGLESFLASH OVER ALL EXT OPGS1x CEDARA7 7/16"HEEL1'-4"1261'-7"1'-0"8:12 PITCH5 3/4" HEEL 124MAINTAIN 6" MIN SEPARATION WOOD to EARTH126F1'-7 7/16"HEEL 1263'-4"1247 7/16"HEEL 8:12 PITCH1'-7"5 3/4"HEEL124 40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.2FPLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/16/2019shutchins 18'-0"8'-4"3'-6"6'-2"3'-8"6'-4"8'-0"ACHVWHFUTURE BEDRM220 SQ. FT.43'-0" 17'-6"13'-4"12'-2"1'-10 1/2"22'-0"18'-0" 16'-11"7'-1" 24'-0" 4'-7 1/2"12'-3 1/2"10'-4"1'-2 1/2"8'-3"10 1/2"16'-3" M.O.8'-3" M.O.UNEXCAVATED6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLMIN. 3'-6" BELOW GRADE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADEA/CSILLCOCK10'-5"5'-0"4'-3"UNFINISHEDMECH.SUMPANCHORS AT 6'-0" O.C.BLOCK AT MIDPOINT14x8 CONC FTG6" HALF-HIGH CURBTREATED BOTTOM PLATE2x6 STUDS AT 16" O.C.2x6 BRNG WALL16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH13'-4"DROPPED BEAM2-62-82-42-624" TOWEL BARW.I.C.2-4FUTUREFAMILY RM694 SQ. FT.UNFINISHEDSTORAGE161 SQ. FT.127 SQ. FT.CONC PAD FTG30x30x12CONC PAD FTG30x30x122x4 BRNG WALLThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C2.0XREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MKRADONVENT PIPETYP. WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.NOTE:8'-4" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRBASEMENT PLAN1/4"=1'-0"2x6 BRNG WALLCONC PAD FTG30x30x127'-6"2'-11"BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMF.B.S.FOUND.BRACINGFOUND.SYSTEM4'-0" MAX 4'-0"MAX.UP 16R DROPPED BEAM5'-0"3'-0"2-6HDRSYSTEMSYSTEMBRACINGFOUNDATIONBRACINGFOUNDATIONNOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONSF.D.42'-0" 1'-0"UNFINISHED2'-0" MFD FLOOR TRUSSES INSTALL PER MFRS SPECS MFD FLOOR TRUSSES INSTALL PER MFRS SPECSNOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOMNOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM1260 SQ. FT.POURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH50'-0"16'-3"5'-0"9'-8"10'-0"20'-0"1'-10 1/2"30'-4"6'-0" 48'-0"19'-8"8"8'-8"8"6x6 TREATED POST16" CONC. PIER FTG.MIN. 3'-6" BELOW GRADECANT. JOISTS(3) 2x8 DROPPED BEAM5'-9"3"CANT.BEAMCANT.BEAM9'-8"(3) 2x8 DROPPED BEAM4'-9" 3"CANT. JOISTSTREATED 2x8's 16" ON CENTERPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE9'-0"6"4'-2"8"CONC PAD FTG36x36x121/2"=1'-0"FRONT PORCH LEDGER SECTION5 3/47 1/4"7 1/4"FLASHING ABOVEDOORTHRESHOLDGRADETOP OF SUBFLOORTO TOP OF JOIST5 3/4" FROM1 1/2"AND BELOW TREATED2x8 LEDGERSTRTD 2x8 JOISTS16" O.C.(8) 10d COMMON NAILSTREATED 2x8(TOP OF FOUND TOBOTTOM OF DECK JOIST)5/4" DECKINGRIM BOARD1-1/8" OSB18" FLOOR TRUSSES(4) PER DECK, RATED AT 750 # EACHSPACED EVENLY, MAX. 24" FROM END OF LEDGERLATERAL LOAD CONNECTION:USP LTS19-TZ w/ LBP12-TZ WASHERR/I3/4B56 SQ. FT.36"TPH 34x48 FBGLSHOWERSURROUNDBRACINGFOUNDATIONSYSTEMWINDOW & DOOR SCHEDULE-LOOKOUTCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#5036 SLIDER0.2960" X 42"BEDROOM0.3215036 SLIDER0.2960" X 42"FAMILY RM.0.3221/2"=1'-0"FRONT PORCH LEDGER DETAIL18" FLOOR TRUSSES 3/4" 1st FLOOR WALLSSUBFLOOR 9'-1 1/8" BASEMENT WALLS 3/4" SUBFLOOR6 1/4"7-1/4"2x8 PORCHLEDGER2x6 EXTERIOR WALL. 2""MIN...5 1/4" 2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE16" O.C. UNDER 10'-0" SPAN12" O.C. OVER 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.FLOOR TRUSSESBLOCKING, LAID FLAT(2) TRTD 2x12(8) 16D NAILS ON INSIDEBLOCKING, LAID FLATTRTD (2) 2x12(8) 16D NAILS PER SIDE(8) 30D NAILS ON OUTSIDELAG SCREWS1/2" DIAMETERINSTALLED STAGGERED IN 2 ROWSLAG SCREWS W/ WASHER TO BEUSP LTS19-TZ STRAPS TO BE ATTACHED TO DECK JOISTOR 2X12 BLOCKING AND ANCHORED INTO FLOOR TRUSS.(4) STRAPS PER DECK/PORCH, RATED AT 750# EACH,TO BE SPACED EVENLY. MAX 24" FROM END OF DECK LEDGERMINIMUM 3" PENETRATION THRU OSB RIM & FLOOR TRUSS48x48x12 CONC. PAD FTG.(5)#5 BARS EACH WAY, SPACEDEVENLY, 3" FROM BOTTOM OF FTG.POINT LOAD FROM ABOVE5'-9"CONC PAD FTG30x30x12AT CLAY OR SILTYSOIL CONDITIONS14'-9"14'-1"10'-2"50'-0"11'-0"5036 SLIDER2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 3'-6" HIGH5036 SLIDER5036 SLIDERCOCKSILL16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHPLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYPLAN OPTIONSLOOKOUT BASEMENT1/2"=1'-0"PORCH SKIRT DETAIL1x10 CEDAR SKIRTAT DROPPED BEAM1x10 CEDAR SKIRTAT DECK RIM JOISTBLOCKING AS REQ.FOR SKIRT SUPPORTDROPPED BEAMFOUNDATION INSULATIONFRONT FOUNDATION WALL:-28 SQ FT/74 LIN FT= 0.38 RATIOR-10REAR FOUNDATION WALL:-25 SQ FT/50 LIN FT= 0.50 RATIOLEFT SIDE FOUND. WALL:-49 SQ FT/18 LIN FT= 2.72 RATIORIGHT SIDE FOUND. WALL:-60 SQ FT/43 LIN FT= 1.39 RATIO-FOUNDATION INSULATIONRATINGS ARE BASED ONLESS THAN 2.6 AIR CHANGESPER HOUR DURING THE AIRLEAKAGE TESTR-10R-10R-15REQUIREMENTS(2) 7-1/4" VERSA-LAM(2) 7-1/4" VERSA-LAM(2) 9-1/2" VERSA-LAM555 2x4 WALLS 5'-7" 5'-6" CABTS. 5'-10" TOP 2x4 WALLS 5'-7" 5'-6" CABTS. 5'-10" TOP 1'-8"8'-4"6'-2"6'-3"11'-0"19'-4"5 1/2"50'-0"41'-4"5 1/2"8'-2 1/2"10'-2"14'-9"11'-0"5'-5"3'-10 1/4"4'-4 1/4"16'-0"43'-0" 17'-6"13'-4" 6'-10 3/4"6'-5 1/4" 12'-10"11'-2" 24'-0"4"12'-6"5'-8"5'-8"6'-2"4'-3"DN 16R 12'-2"DROPPED BEAM24'-0"6'-0"8'-6"42'-0"18'-0"3'-6"2'-10 1/4"2'-9"4 3/4"8'-0" HIGH SROCABINETS3'-6"9"x12" DROPPEDSOFFIT50'-0"10'-0"20'-0"10'-4"4'-10"4'-10"10'-0"10'-0"5'-0"5'-4"5'-1"2'-3"2'-8"7'-4"UP 16RTYPICAL PORCH COLUMN:4'-9"9'-8"9'-6"3"DROPPED BEAM2W 3060 SH3050 SH3040 SHGIRDER TRUSSThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C3.0X16x7 OVERHEAD DOOR8x7 OVERHEAD DOOR10" TREAD CUT2-82-4SINKDWCPT.HD-FLR2-82-03-0 W/TRANSOM16" WIDE DROPPED SOFFIT(SEE SECTION)22x30ATTICACCESSGARAGESLOPE TO DOORS4" CONC FLOORON ALL WALLS & CEILINGGYPSUM BOARDNOTE: 708 SQ. FT.TYPICAL 2x6 GARAGE WALLS1/2BHD-FLRTPH24" TOWEL BARFAMILYROOMCPT.KIT.HD-FLRFOYERHD-FLROWNERSENTRYHD-FLRCOVEREDWOOD PORCHSTUDYCPT.1ST FLOOR PLAN1/4"=1'-0"1382 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 8'-0" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR14" MFD I-JOISTS INSTALL PER MFRS SPECS 14" MFD I-JOISTS INSTALL PER MFRS SPECS 6'-0" 2'-6"108 SQ. FT.4'-0 7/8"4'-5 1/8"2020 FX14" MFD I-JOISTS INSTALL PER MFRS SPECS 4'-0"4'-6"2-0RADONVENT PIPEISLAND W/FLUSH TOPSAME HEIGHT ASBASE CABINETSFRAME WALL @1'-0"2x6 WALL 12'-1 1/2"INSIDE FRAMING24"BASE24"BASE7'-10 1/4"INSIDE FRAMING22'-0"2'-0" 1'-0"2) 2-6N.C.DROPPED BEAM7'-6"7'-11"4'-3"10'-5"5'-0"5'-0" 3" 5'-9"3"MFD BEAMFLUSH AT SUBFLOORDROP GARAGE TOP PLATES10" FROM HOUSE TOP PLATESDROP GARAGE TOP PLATES10" FROM HOUSE TOP PLATES ISLAND W/FLUSH TOPSAME HEIGHT ASBASE CABINETSFRAME WALL @SET AT 8'-0" HIGH9'-8"4'-10"3"8x8 MFD COLUMN W/2x6 CAP & BASE ANDCOMMANDCENTERHD-FLRDININGDINETTEHD-FLRWOOD STEPS2'-6"8'-6"8'-6" 11"4'-8"6'-10"4'-8"5" INSIDE FRAMINGINSIDE FRAMING 14" TRANSOM6068 SGD W/VERSALAM COLUMS UPTO BOTTOM OF GIRDERTRUSS (NO TOP PLATES)EXTEND 5-1/4X5-1/4MFD TRUSSES AT 24" O.C.10" BEAMPOCKET3W 3060 SH0.3172 1/8" X 72"0.31WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DOOR W/ TRANS0.3138.25" X 95.25"FOYER0.2311COMMAND3040 SH2W 3060 SHSTUDY13050 SHDINING13040 SHKITCHEN16068 SGD W/ TRANS.DINETTE12020FXOWNERS ENTRY10.3136 1/4" X 60 1/4"0.310.3136 1/4" X 48"0.310.3136 1/4" X 48"0.3124" X 24"0.310.320.3172 1/8" X 94"0.323040 SHREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MKFROM TOP OF SUBFLOOR TOSET KITCHEN WINDOWS 43 1/2"RGH.OPG. OF WINDOW1FAMILY ROOM0.310.323W 3060 SH108" X 72"4'-2"43 1/2" FROM TOP OF SUBFLOOR TOSET COMMAND CENTER WINDOWSRGH.OPG. OF WINDOWWINDOW AT 7'-0"SET DINING RMABOVE SUBFLRWINDOW AT 7'-0"SET ENTRYABOVE SUBFLRFLEX ROOM10.310.30OPT 3W 2020 FX72" X 24"WOOD RAILINGREF.2'-3"MICRO HOOD20 AMP.CIRCUITCOOKTOP2'-3"OVENWICHD-FLRPANTRYHD-FLR1'-11 3/4"2-0HD-FLRMICRO HOODVENTTO OUTSIDETILE BACKSPLASHPED.PLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYPLAN OPTIONSCOMMAND CENTER CABINETSGAS FIREPLACESIGNATURE KITCHENRAILING AT STAIRSTILE BACKSPLASH @ KITCHENWALK-IN PANTRYGAS FPR.O. 42"x 40-1/8"2'-0"GASFRAME SOFFIT @8'-1" FROM TOP SUBFLOORTO BOTTOM OF FRAMING556666664773.53.5PFHPFH(2) 9-1/2" VERSA-LAM(2) 11 7/8" VERSA-LAM(1) 14" VERSA-LAM(2) 7-1/4" VERSA-LAM(2) 11 7/8" VERSA-LAM(1) 14" VERSA-LAM(2) 7-1/4" VERSA-LAM(3) 24" VERSA-LAM(2) 11 7/8" VERSA-LAM(2) 9-1/2" VERSA-LAM 50'-0"12'-8"6'-6"12'-0"5'-6"13'-4"10'-6"2'-2"9'-10"2'-2"2'-2"11'-2"43'-0" 11'-2"2'-6"15'-4"14'-0" 7'-7 1/8"7'-8 7/8"50'-0"9'-8"10'-0"20'-0"10'-4"4'-10"4'-0"10'-0"10'-0"18'-0"11'-4"6'-8"6'-0"43'-0"2'-4"18'-0"4'-4"9'-0"3'-8"5'-6"5'-2"3'-0"3'-9"15'-5"8"9'-8"3'-8"2'-4"4'-4" 4'-8"2-42-65-02-62-42-42-42-62-82-610'-0"3050 SH3050 SHA.P. 2x6 WALL 5-0 FBGLTUB/SHWRWASHDRY2040 SH2W 3050 SHW/ WOOD CAP 3050 SH4'-11"5'-1"3040 SHTEMP. GL.3W 3050 SHTPH24" TOWEL BAR2x6 WALL22x30ATTICACCESSThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C4.0XBEDRM #2CPT.BEDRM #3CPT.BEDRM #4CPT.OWNERSBEDRMCPT.ROOMCPT.GAMEW.I.C.CPT.W.I.C.CPT.LAU.HD-FLRLIN.CPT.DN 16R2ND FLOOR PLAN1/4"=1'-0"1702 SQ. FT.LIVING AREANOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRRADONVENT PIPE3050 SH42" HIGH HALF WALL 2'-8"REDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MK8" 1'-0"17'-0"1'-0"7'-2"5'-0"3'-9"OWNERSBATHHD-FLR42x60PROVIDEFBGL TUBACCESS66"2-43'-3"2-42-4TPH24" TOWEL BARMFD TRUSSES AT 24" O.C. 2x6 WALL GIRDER TRUSSNICHENOTES:ALL TOE LEDGES AND SEATSARE 18" OFF THE SUBFLOORBTILE REDI NICHE MODEL#1620D-B1R.O. 14-1/2" (w) X 18-1/2" (h)ATOE LEDGES ARE MODEL BT-17BY BETTER BENCH SYSTEMSDSEE FLOOR PLAN FOR LOCATIONOF THE SHOWER NICHES.MIXER VALVE IS ALWAYSCENTERED BELOW SHOWER HEADNICHE THAT IS OFFSET IN SHOWERIS 3'-9" OFF SUBFLOORCW.I.C.CPT.3'-8"48" HIGH, 2X4HALF WALLMFD TRUSSES AT 24" O.C.MFD TRUSSES AT 24" O.C.10"9'-8"3'-9" ABOVE SUBFLOOR SHAMPOONICHEPRE-MFR'DR.O. = 14 1/2"R.O.= 18 1/2" CENTER OF SHWR HEAD OPG 84" ABOVE SUBFLOOR OWNERS BATH W/1/2"=1'-0"SHOWER BASEFIBERGLASS BASE18"DETAIL 'A'36X60 FIBERGLASSCL16" @ 34" SHWR4'-0"CLSHOWERCONTROLTO CENTER OF SHOWER VALVE TO BOTTOM OF NICHE SEATS & TOE LEDGES 10-3/4"36"VALVE17-3/16" @ 36" SHWRWINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3040 SH1OWNERS BATHGAME ROOM12W 3050 SH3050 SHBEDRM #213050 SHBEDRM #313050 SHBEDRM #412040 SHLAUNDRY13050 SH1OWNERS CLOS.3W 3050 SH1OWNERS BDRM0.3136 1/4" X 48"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.31108" X 60 1/4"0.310.3124" X 48"0.310.310.3172 1/8" X 60 1/4"3'-4"3'-8"w/ WOOD CAP72"5'-8" INSIDE FRAMING BATH #2HD-FLRTOELEDGEW/ CT SURROUND34x60 FBGL BASESEE SHWRDETAIL 'A'WIRE SHELFPLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYPLAN OPTIONS2ND SINK AT BATH #2C.T. SURROUND AT O. BATH SHOWER(2) 9-1/2" VERSA-LAM3355444444444 ACHVWHFUTURE BEDRMUNEXCAVATEDUNFINISHEDMECH.SUMPFUTUREFAMILY RMUNFINISHEDSTORAGEThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C5.0XREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MKNOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONSF.D.SDS SEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLEGFIWP15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLELOW VOLTAGESYSTEM RECEPTACLEELECTRICAL PLAN1/4"=1'-0"UNFINISHED BASEMENTA/CR/I3/4BW.I.C.RADONVENT PIPESMART HOMESYSTEM RECEPTACLEWATER SOFTRECEPTACLEPLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYPLAN OPTIONSLOOKOUT ELEVATIONLIGHT FIXTURE SCHEDULEDOME LIGHTLED DISC LIGHTRECESSED FIXTLRPEND.PENDANT LIGHTSWALL FIXTURESCEILING LIGHTD These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6.0XGARAGE1/2BCOMMANDCENTERFAMILYROOMDININGFOYERDINETTEOWNERSENTRYCOVEREDPORCHSTUDYELECTRICAL PLAN1/4"=1'-0"RADONVENT PIPEWICREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MKSSS SS SSSSSS GFISSFANSUSBGFIPHSSDISP.SWPSTSD LLLLCSSPRINKLERSYSTEMRECEPTACLE WP1ST FLOORBEDRM #2BEDRM #3BEDRM #4OWNERSBEDRMROOMGAMEW.I.C.W.I.C.LAU.LIN.BATH #21/4"=1'-0"RADONVENT PIPEOWNERSBATHROUGH-INCEILING FANSSSDSS SDSDSD/CMDSGFIFANGFIS S S S SDCS S SS LLLLLLS GFI GFISFANW.I.C.SLELECTRICAL PLAN2ND FLOORLLS SFANSLSSS CHIMESHCPSSSMART HOMERECEPTACLELLLLLDDDDDDDLLLLLLLLLTECH TUBECENTEREDABOVE F.P.PANTRYSLKIT.PEND.PEND.PEND.PEND.LLLLLLSC/D C/D PLANSPERMIT / CONST.LOT 10, BLK 3, CHOKECHERRY HILL 4TH ADD.18892 HOUSTON WAYPLAN OPTIONSCOMMAND CENTER CABINETSMAIN LEVEL FAMILY ROOM LIGHT PACKAGESIGNATURE KITCHENGAS FIREPLACEC.T. SURROUND @ OWNER'S SHOWERKITCHEN PENDANT LIGHTSDINETTE LIGHT PACKAGETILE BACKSPLASH @ KITCHEN2ND SINK AT BATH #2WALK-IN PANTRYSTAIR RAIL LIGHT FIXTURE SCHEDULEDOME LIGHTLED DISC LIGHTRECESSED FIXTLRPEND.PENDANT LIGHTSWALL FIXTURESCEILING LIGHTDMVENT HOODTO OUTSIDE These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C7.0XREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MKMFD TRUSS9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-1 1/8"8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR4" CONC. FLOORGARAGE24'-0"18'-0"1/4"=1'-0"CROSS SECTION B-B6'-0"18'-0"MFD TRUSSDINETTELIN.W.I.C.W.I.C.OWNERSBEDRMMFD BEAMMFD TRUSS1'-4"6127 7/16"HEEL 3'-4"1'-7 9/16" HEEL 9'-1 1/8"10'-3 7/8"CONC WALL9'-8 3/4"8'-2"8'-1 1/8"3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR4" CONC. FLOORBEDRM #4LAU.GARAGE22'-0"18'-0"1/4"=1'-0"CROSS SECTION A-A1/2BCOMMANDCENTEROWNERSENTRYEXTEND BOTTOM CHORD 5-1/2"FOR "LET-IN" BEARING36'-0"14" MFD I-JOISTSMFD TRUSS612MFD TRUSS1'-4"6127 7/16"HEEL3/4" SUBFLOOR3/4" SUBFLOOR14" MFD I-JOISTS1'-4"7 9/16" HEEL6 12FLUSH AT SUBFLOOR10"1'-4"7 7/16" HEEL 9'-11 3/8" 9'-11 3/8" 10"DROP 18" MFD FLOOR TRUSSES18" MFD FLOOR TRUSSESMFD TRUSS9'-1 1/8" 10'-3 7/8"9'-8 3/4" 8'-2"8'-1 1/8"CONC WALL3/4" 250 SUBFLOOR3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORGIRDER TRUSS 2x6 BRNG WALL 2x6 BRNG WALL LIVINGROOMDININGFAMILYROOM1/4"=1'-0"CROSS SECTION D-DROOMGAMEBEDRM #2W.I.C.36'-0"7'-0"9'-1 1/8" 10'-3 7/8"9'-8 3/4" 8'-2"8'-1 1/8"1/4"=1'-0"CROSS SECTION C-CCONC WALL3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORDROPPED BEAMOWNERSBATHBATHKITCHENFOYERCOVEREDSTOOP36'-0"6'-0"13" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE1'-1"1'-4"6127 7/16" HEEL 14" MFD I-JOISTSMFD TRUSS1'-4"6127 7/16" HEEL GIRDER TRUSS COVEREDSTOOP14" MFD I-JOISTS6'-8"MIN HEADROOM HAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATADROPPED BEAMFLAT FRAME FORLIGHTING FIXTURE1'-0"2x8 JOISTS(3) 2x8DROPPED BEAM5'-0"3"4'-9"CANT.JOISTSPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADESET ON 10" THICKPOURED CONC. WALLCONC. SIDEWALK18" MFD FLOOR TRUSSES18" MFD FLOOR TRUSSES6'-8"MIN HEADROOM 12'-0"6'-0"2x8 JOISTS(3) 2x8DROPPED BEAM3"5'-9"CANT.JOISTSPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADESET ON 10" THICKPOURED CONC. WALLCONC. SIDEWALK1'-7"5'-9"1245 3/4" HEELDROPPED BEAM13" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE1'-1"1'-7"4'-9"1245 3/4" HEEL These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C8.0XREDWOOD-5475-C-3.1PC#651: 5-1-2019-LLPERMIT/CONSTRUCT:7-29-19-MK1/2"=1'-0"BEAM DETAIL3 PLY 24" BEAMFLUSH AT TOP W/SUBFLOOR &NOT SHOWN FOR CLARITY)2X6 EXTERIOR WALLSTANDARD HEIGHT8'-1 1/8"14" I-JOISTS3/4" SUBFLOOR(FLUSH ON TOPW/ LVL BEAM)25"5"SOLID VERTICALBLOCKING IN GIRDERTRUSS (26" HIGH)2X6 EXTERIOR WALLFRAME OVER 'HUMP'IN GIRDER TRUSSGARAGE SLAB LEDGE DETAIL1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"THE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.5/8" GYP. BD.TYPICAL WALL SECTION1/2"=1'-0"9'-1 1/8"TRUSSES PER PLAN3/4" SUBFLOORVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C H U T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806EXT. SPRAY-ON WATERPROOFINGWATCH DOG + ENERGY SYSTEMTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINUOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ SILL SEALERMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.JOISTS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTED1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEFINISHED GRADEWILL VARYJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALL(SEE OSWELL ENGINEERING)R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=203.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTRUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTERALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTURE(IF REQUIRED PER FOUNDATIONEXTEND OVER SILL PLATER-5 RIGID INSULATION(AT RIGHT AND LEFT SIDEOF HOME ONLY)SEALED AND TAPED AT TOPCALCULATIONS, R402.2.8.A)R-5 RIGID INSULATION(AT SIDE LOOKOUT FOUNDATION ONLY,NOT AT REAR LOOKOUT WALLS)R-5 RIGID INSULATION-ON INSIDETAPE & SEAL AT TOPFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEDRAINTILE AT WALKOUT WALLS(HILLCREST ONLY)W/ R-10 DRAINAGE BOARDROLL-ON WATERPROOFINGWALL EDGE, ACROSS THE TOP, ANDEXTEND FROM TOP INTERIOR6" DOWN THE EXTERIOR WALL FACEGIRDER TRUSS (WEBSGIRDER TRUSSTHGQH5.5 / HGU550HANGER OR EQUIV.9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-2"8'-1 1/8"CONC WALL3/4" 250 SUBFLOOR3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR14" MFD I-JOISTSGARAGE4" CONC. FLOOR1/4"=1'-0"LONGITUDINAL SECTION E-E30'-4"ROOMGAME20'-0"10'-4"DININGBEDRMOWNERSGIRDER TRUSSVERIFY HEIGHT9'-11 3/8"10"18" MFD FLOOR TRUSSESLIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12"4"4" DIA. HOLE14"TO TOP OFSTONE VENEER 1"=1'-0"WALL DETAILLOOKOUT FINISH2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/2"=1'-0"FLOOR DETAILDENSE PACK FIBERGLASS3/4" SUBFLOOR6" ROUND DUCTWORKMANUFACTURED I-JOISTSR-8 INSULATION WRAPNETR-30 SPRAY FOAM INSUL.4.34" AROUND DUCTWORK(R-6.9 PER INCH)BLOWN-IN INSULATION1" CLOSED-CELLSPRAY FOAM5/8" GYP. BD. SSCOPE OF WORK:INDEX:S1 - Scope, Index, and CertificationS2 - General NotesS3 - Standard Bearing Wall DetailS4 - Standard Non-Bearing Wall Joist Blocking DetailS5 - Bottom Chord Bearing Truss Non-Bearing Wall DetailS6 - Top Chord Bearing Truss Non-Bearing Wall DetailMATERIALS:Concrete: Minimum 28 day compressive strength (F'c) of 3000 psi for wallsMinimum 28 day compressive strength (F'c) of 5000 psi for footingsMasonry:Minimum 28 day prism strength (F'm) of 1500 psiBackfill Soil:Sand - 30 psf/ft effective lateral pressureSandy Clay - 45 psf/ft effective lateral pressureClay - 60 psf/ft effective lateral pressureSITE ADDRESS:Street:City:State: MN Zip:Craig Oswell, PE (MN #42341)Oswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support GuideDescription: Scope of Work, Index, and CertificationProject # 18.099Client Name: Builder's Association of Minnesota (BAM)34The drawings are to only be used by the Builder's Association of Minnesota (BAM) and its members. Refer to BAM's website for the most current version of these drawings. These drawings are to be provided to the building inspection department as part of the permit package.I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the state of Minnesota.Page S1 of S6Fax: 612-886-2966www.oswellec.com2019 BAM Top of Foundation Wall Support Guide1/1/20191901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Footings may be 3000 psi if an approved admixture is used to achieve a water and vapor resistance equivalent to 5000 psiThese drawings are an illustrative representation of an alternative option to the top of wall support information contained in the 2012 International Residential Code (IRC) section 404.1, as adopted by the 2015 Minnesota State Building Code. These drawings apply to the construction of top of full height cast-in-place concrete, insulated concrete form, and masonry basement foundation walls for typical residential cases. These drawings are not to scale and all conditions are to be verified by the contractor. Means and methods of construction for shoring, water-proofing, insulation, flashing, and all other non-structural requirements are to be by others in accordance with the Code and standard industry practice. These drawings are valid through December 31, 2019.GGENERAL NOTES:1.2.3.4.Use of multiple sill plates is not allowed unless specifically noted.5.6.7.8.9.10.11.* = see note 11 above for alternate anchor optionsOOswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support GuideDescription: General NotesProject # 18.099Client Name: Builder's Association of Minnesota (BAM)34Anchor bolts may be substituted with 1/2" diameter threaded rod epoxy grouted at same spacing with 7" embed.Alternate anchors may be Simpson MAB, Simpson MASA, USP ST, USP FA3, Simpson FWAZ, or 1/2" diameter expansion anchors with 6" minimum embedment, or an equivalent manufactured anchor.1/1/2019Sill plates may need to be larger than the minimum to meet Energy Code or other requirements. The exact size of the sill plate is the responsibilty of the contractor.Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of adequate shoring by others is required until the final floor and slab systems are in place.Sill plate sections require at least two anchors with one within 4" to 12" of each end and at all corners and intersections. Walls less than 24" in length require only one anchor. This packet applies to full height walls less than ten feet in clear height supporting unbalanced fill only. This packet does not apply to lookout and frost style walls. The details in this packet are not limited by wall length or plan dimensions. This packet applies to traditional floor joists, I-joists, and trusses. All floor members are to bear at least 3.5" on the sill plate unless noted otherwise. Sill plates may over overhang the face of the wall provided the overhang is not loaded vertically and all anchor bolt/connection tolerances are met.All premanufactured connectors and anchors are to be installed in accordance with their manufacturer's recommendations.FFax: 612-886-2966wwww.oswellec.comPage S2 of S6PPhone: 612-720-463911901 E Hennepin Ave, #201MMinneapolis, MN 5541372"72"72"24"48"40"72"36"48"16"72"72"72"72"72"72"72"TTOP OF WALL ANCHOR SPACING TABLEBBACKFILL HEIGHT ABOVE SLABANCHOR BOLTALTERNATE ANCHOR*ANCHOR BOLTALTERNATE ANCHOR*ANCHOR BOLTSSANDSSANDY CLAY8'-6"16"32"32"9'-6"64"24"40"16"24"8"72"72"72"64"72"72"32"64"24"72"40"56"24"110'-0"CLAYALTERNATE ANCHOR*SOIL TYPE72"7'-6"5'-6" or less8'-6"6'-6" or less7'-6"6'-6"48"16"7'-6" or less72"72"Slope grade 6" minimum downward away from foundations within first 10 feet or provide Code compliant swale.Anchor bolts 1/2" or larger in diameter do not require corrosion protection per IRC section R317.3.1, exception 1.72"CLEAR HEIGHT (Top of Slab to Top of Wall)8'-0" or less9'-0"64"16"72"32"8"72"32"56"Alternative to MN Code Table R404.1(1)48" 6" MinTTYPICAL TOP OF FOUNDATION WALL DETAILNNotes:1.2. USP LJQ must be sized appropriately for the actual floor member width.3.Floor members must be at least 3" wide when two Simpson A35/USP MPA1's are used.4. Connection C may be installed at every other floor member if the number of anchors is doubled.5. As an alternative, connection C may be installed at every fourth floor member.6. As an alternative, connection C may be installed at every third floor member.7. As an alternative, connection C may be installed at every other floor member.Oswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support Guide##Description: Typical Bearing Wall DetailProject # 18.099Client Name: Builder's Association of Minnesota (BAM)34Page S3 of S61901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.com8'-0" or lessCC19.2"24"A (note 5) A (note 7)A (note 6)A (note 7)BC16"1/1/20199'-0"10'-0"16" A (note 7)CCA (note 7)BBBDCCCLEAR HEIGHT (Top of Slab to Top of Wall)CCDDD24"DCWood floor joist, I-joist, or trusses & wall framing by othersFLOOR MEMBER TO SILL PLATE CONNECTION TABLEAlternate to MN Code Table R404.1(1)CLASS (weakest to strongest)DESCRIPTION2x6 minimum sill plate w/ 1/2" diameter anchor bolts w/ 7" minimum embed & 2" wide x 1/8" thick square or round countersunk flush washers or alternative anchor (see table on S2 for spacing) (Anchor bolt clearance between edge of both wall and sill plate is to be 2.5")CLAYBACKFILL TYPEFLOOR MEMBER SPACINGSANDSANDY CLAYSee table below for connection of each floor member to sill plateFoundation wall per Code by others (clear height is measured from top of basement slab to top of foundation wall)CONNECTION TYPEDSimpson FWANZ, Simpson U2.1/4, Simpson U2.37/4, USP LJQ, or (2) USP MPA1/Simpson A35 (see notes 1 to 3)Simpson FWANZ requires 1.125" minimum OSB rim and must be located within 5" the floor member. For trusses, it must be in contact with the member or 2x4 minimum continuous bottom bracing must be provided.ABC(3)0.131" diameter x 3" long toe/top nails(3)0.148" diameter x 3" long toe/top nailsUSP LJC or USP MPA1/Simpson A35 (see note 4)DD19.2"24"16"19.2"JJOIST BLOCKING DETAILBlocking spacing to match anchor bolt spacing (see S2)NOTES:1.2.3.Toe nail blocking members in place as required for stabilty.4.5.6.All nails are to be spaced in members such that splitting does not occur.7.Foundation wall is to be per Code by others.Oswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support GuideDescription:Standard Non-Bearing Wall Joist Blocking Detail (NOT TO SCALE)Project # 18.099Client Name: Builder's Association of Minnesota (BAM)341/1/2019Bays containing blocking do not need to be directly next to the wall or each other provided 2x4 spacer blocking is installed between them as shown. Toe nail spacers in place as required.Full height blocking may contain 4" diameter maximum holes if required for electrical/plumbing. Provide at least 3" edge clearance for all holes.Page S4 of S61901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comBlocking shown may be replaced with pre-manufactured blocking provided it can resist at least 1500 pounds of lateral compression.Nail the floor sheathing to the blocking w/ at least (12) 0.131" diameter x 3" long nails evenly spacedWall framing, joists, & structural rim by othersFloor sheathing is to be 3/4" minimum thick OSB/plywood installed in a staggered pattern. Nail to floor members with 0.131" diameter x 3" long nails at 6" o.c. at all panel edges/perimeter and 12" o.c. at all intermediate supports or an approved equivalent.Use Class D connection from S3 for blocking to sillSee note 4 for spacers as required at mechanical onlyInstall full height 2x or I-joist blocking as required to achieve the nailing noted (minimum of two spaces), spaces used do not need to be next to each other if spaces between are blocked per note 42x6 minimum sill plate w/ 1/2" diameter anchor bolts w/ 7" minimum embed & 2" wide x 1/8" thick square or round countersunk flush washers or alternative anchor (see table on S2 for spacing) (Anchor bolt clearance between edge of both wall and sill plate is to be 2.5"), NOTE: Sill plate may have to be increased to 2x8 to fit Class D connectorsBBOTTOM CHORD BEARING TRUSS BLOCKING DETAILBlocking spacing to match anchor bolt spacing (see S2)NOTES:1.2.3.Toe nail blocking members in place as required for stabilty.4.5.6.All nails are to be spaced in members such that splitting does not occur.7.Foundation wall is to be per Code by others.8.Do not cut rim truss bottom chord for any reason.Oswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support GuideDescription:Non-Bearing Wall Bottom Chord Bearing Truss Blocking Detail (NOT TO SCALE)Project # 18.099Client Name: Builder's Association of Minnesota (BAM)341901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-46391/1/2019Fax: 612-886-2966www.oswellec.comPage S5 of S6Bays containing blocking do not need to be directly next to the wall or each other provided 2x4 spacer blocking is installed between them as shown. Toe nail spacers in place as required.OSB/plywood blocking may contain 4" diameter maximum holes if required for electrical/plumbing. Provide at least 3" edge clearance for all holes.Nail the floor sheathing to the blocking w/ at least (12) 0.131" diameter x 3" long nails evenly spacedWall framing, trusses, & structural rim by others2x6 minimum sill plate w/ 1/2" diameter anchor bolts w/ 7" minimum embed & 2" wide x 1/8" thick square or round countersunk flush washers or alternative anchor (see table on S2 for spacing) (Anchor bolt clearance between edge of both wall and sill plate is to be 2.5"), NOTE: Sill plate may have to be increased to 2x8 to fit Class D connectorsFloor sheathing is to be 3/4" minimum thick OSB/plywood installed in a staggered pattern. Nail to floor members with 0.131" diameter x 3" long nails at 6" o.c. at all panel edges/perimeter and 12" o.c. at all intermediate supports or an approved equivalent.See note 4 for spacers as required at mechanical onlyInstall 2x4 minimum flat blocking between trusses as required to achieve the nailing noted (minimum of two spaces), spaces used do not need to be next to each other if spaces between are blocked per note 4Install 3/4" minimum thick OSB/plywood to one side of 2x4 blocking w/ (6)0.131" diameter x 3" long nails top & bottom OR 1/2" minimum thick OSB/plywood to each side w/ (4)0.131" diameter x 3" long nails top & bottomUse Class D connection from S3 for blocking to sillNail rim truss bottom chord to sill plate w/ 0.148" diameter x 3" long nails @ 6" o.c.Blocking shown may be replaced with pre-manufactured blocking provided it can resist at least 1500 pounds of lateral compression.TTOP CHORD BEARING TRUSS BLOCKING DETAILBlocking spacing to match anchor bolt spacing (see S2)NOTES:1.2.Toe nail blocking members in place as required for stabilty.3.All nails are to be spaced in members such that splitting does not occur.4.Foundation wall is to be per Code by others.Oswell Engineering and Consulting, L.L.C.Project Name: 2019 BAM Top of Foundation Support GuideDescription:Non-Bearing Wall Top Chord Bearing Truss Blocking Detail (NOT TO SCALE)Project # 18.099Client Name: Builder's Association of Minnesota (BAM)341/1/2019Nail the floor sheathing to the blocking w/ at least (12) 0.131" diameter x 3" long nails evenly spacedWall framing, trusses, & structural rim by othersPage S6 of S6Install 2x4 minimum flat blocking between trusses as required to achieve the nailing noted (minimum of second space)2x6 minimum sill plate w/ 1/2" diameter anchor bolts w/ 7" minimum embed & 2" wide x 1/8" thick square or round countersunk flush washers or alternative anchor (see table on S2 for spacing) (Anchor bolt clearance between edge of both wall and sill plate is to be 2.5")Floor sheathing is to be 3/4" minimum thick OSB/plywood installed in a staggered pattern. Nail to floor members with 0.131" diameter x 3" long nails at 6" o.c. at all panel edges/perimeter and 12" o.c. at all intermediate supports or an approved equivalent.1901 E Hennepin Ave, #201Minneapolis, MN 55413Additional sill plates as required by others to match truss top chord depthInstall treated double 2x blocking ripped to fit height of sill plates in first bayPhone: 612-720-4639Fax: 612-886-2966www.oswellec.com SSCOPE OF WORK:INDEX:S1 - Scope, Index, and CertificationS2 - General NotesS3 - Step Footing DetailS4 - Frost Wall DetailS5 - Lookout Wall DetailS6 - Full Height Wall DetailMATERIALS:Reinforcing Steel:: Grade 40 (40 ksi) for #4 and smaller bars Grade 60 (60 ksi) for #5 bars and largerRebar Substitution Notes:1.Two #4's bundled may be used to substitute (1)#6 and vice versa provided they are of the same grade steel.2.For vertical bars on S6, #5's may be used in lieu of #6's at two-thirds of the noted spacing.Concrete: Mix design is to be prepared by the concrete supplier to meet the project's requirementsMinimum 28 day compressive strength of 3000 psi for wallsMinimum 28 day compressive strength of 5000 psi for footingsBackfill Soil:Sand - 30 psf/ft effective lateral pressureSandy Clay (SC) - 45 psf/ft effective lateral pressureClay - 60 psf/ft effective lateral pressureSITE ADDRESS:Street:City:State: MN Zip:Craig Oswell, PE (MN #42341)Oswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription: Scope of Work, Index, and CertificationProject # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 55372342019 Standardized Concrete Foundation Drawings1/1/2019The drawings are to only be used by the contractor noted below or his authorized sub-contractors/clients. These drawings are to be provided to the building inspection department as part of the permit package.These drawings apply to the construction of cast-in-place concrete foundation walls for typical residential cases. These drawings are not to scale and all conditions are to be verified by the contractor. Means and methods of construction for shoring, water-proofing, insulation, flashing, control and construction joints, and all other non-structural requirements are to be by others in accordance with the Code and standard industry practice. These drawings are valid until the end of 2019.1901 E Hennepin Ave, #201Footings may be 3000 psi if an approved admixture is used to achieve a water and vapor resistance equivalent to 5000 psiI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the state of Minnesota.Page S1 of S6Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comGGENERAL NOTES:1. Wall thicknesses noted are nominal unless specifically stated otherwise. 2. Maximum wall to footing centerline offset is 2". A minimum of 2" of footing is to extend on each side of the wall.3. Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60.4. Bend horizontal bars or provide matching hooks around all wall corners and intersections.5. Horizontal bars may be placed anywhere within the wall thickness provided 2" minimum cover is provided.6. Allowable bar placement tolerance is 1/2". Tying is not required if tolerances are met and maintained.7.8.9. Anchor bolts 1/2" or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1.10.Anchor bolts may be substituted with 1/2" diameter threaded rod epoxy grouted at same spacing with 7" embed.11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings.12. Slope grade 6" minimum downward away from foundations within first 10 feet or provide Code adequate swale.13.14.CCOLD WEATHER GUIDELINES:1.2.Concrete is to be delivered to the site in a timely manner. 3.Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised.4. Do not add additional water. Using water-reducing admixtures is recommended when required.5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground, snow, or ice.6. Preheating of rebar is not required, however it is to be free of frost, snow, and ice.7.OOswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription: General NotesProject # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 5537234Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels may be bent down for safety and covering then bent back before wall placement.The following information is general guidelines for the placement of concrete in cold weather conditions. It is the contractor's responsibility to ensure proper means and methods are followed and that the final in place product is adequate.11901 E Hennepin Ave, #201MMinneapolis, MN 55413Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures below 10 degrees F and for the whole wall when below zero degrees F.The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions expected. Use of extra cement, early-strength concrete, and accelerators are recommended at temperatures below 20 degrees F.Sill plate sections require at least two anchors with one within 4" to 12" of each end and at all corners and intersections. Walls less than 24" in length require only one anchor. Sill plates may overhang the face of the wall provided the overhang is not loaded vertically and all anchor bolt/connection tolerances are met.Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of adequate shoring is required when the final floor and slab systems are not in place and fully anchored.Maximum inside window well dimension is 72". Well walls are to be at least 8" thick placed monolithically with house walls with horizontal bars extended into them and around corners. Provide two additional vertical bars and one additional anchor bolt each side of opening. Opening header by others.1/1/2019FFax: 612-886-2966wwww.oswellec.comPage S2 of S6PPhone: 612-720-4639HHIGH FOOTINGLOW FOOTINGFOOTING STEP DETAILOswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription:Step Footing Detail (NOT TO SCALE)Project # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 5537234Adjacent steps are to be placed no closer to either side of the beam section than twice the height of the largest step6'-0" maximum stepOptional control joint each end of beam section by others24" min(2) bundled #4 horizontal bars top & bottom w/ 3" min clearance extended at least 24" minimum beyond each end of beam section (bar length = step height + 4')High footing should be placed at 1-to-1 (45 degree) line, if high footing is closer to step than this line, place beam section rebar as if it was at this line as shown1/1/2019(beam section)www.oswellec.comPage S3 of S6Phone: 612-720-4639Fax: 612-886-29661901 E Hennepin Ave, #201Minneapolis, MN 55413Maximum applied actual load = 4000 plf uniform or 12,000 pound concentrated6" minimum thick cast-in-place concrete foundation wallWall framing by othersWWALKOUT/ SLAB-ON-GRADE FROST WALL DETAILNote: Maximum unbalanced fill height is 36" for 8" thick wall & 48" for 10" wallOOswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription:Frost Wall Detail (NOT TO SCALE)Project # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 5537234Grade to be at least 6" below top of wallSill plate by others w/ 1/2" diameter anchor bolts w/ 7" minimum embed & standard washers @ 72" o.c. max or equivalent metal strap anchors (Anchor bolt clearance between edge of both wall and sill plate is to be 2")6" minimum thick cast-in-place concrete wallPage S4 of S6(1)#4 continuous horizontal bar w/in 18" of top of wall1901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.com#4 x 2'-0" long dowels @ 72" o.c. max w/ 5" minimum embedUnreinforced concrete strip footing per Code by others, provide frost protection per Code as required1/1/2019Optional slab ledge, maximum stem height is 12" w/ width to match sill plateWall framing by others66" wall spacing:8"+ wall spacing:LOOKOUT WALL DETAILOswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription:Lookout Wall Detail (NOT TO SCALE)Project # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 5537234Grade to be at least 6" below top of wallSill plate by others w/ 1/2" diameter anchor bolts w/ 7" minimum embed & standard washers @ 72" o.c. max or equivalent metal strap anchors (Anchor bolt clearance between edge of both wall and sill plate is to be 2")Page S5 of S6(1)#4 continuous horizontal bar w/in 18" of top of wall1901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comFooting elevation may vary below slab, provide frost protection per Code8" thick x 18" wide minimum unreinforced concrete strip footing (16" wide minimum for maximum unbalanced grade of 2'-6" or less), larger footing width may be required for specific soil bearing conditions to be determined per Code by others6" minimum thick cast-in-place concrete wall#4 x 2'-0" long centered dowels w/ 5" minimum embed wet set or epoxy grouted in place32" o.c. max for sand & 24" o.c. max for SC & clay 48" o.c. max for sand, 42" o.c. max for SC, & 36" o.c. max for clay 1/1/20193'-2" maxWood floor & wall framing by othersGrade to be at least 6" below top of wallBBASEMENT WALL DETAILTTable Notes:(1) = (2) = Allowed alternate anchors are:Oswell Engineering and Consulting, L.L.C.Project Name: 2019 Standardized Concrete Foundation DrawingsDescription: Full Height Wall Detail (NOT TO SCALE)Project # 18.100Client Name: Ostertag Cement, Inc.Client Address: 14198 Commerce Ave NE #300, Prior Lake, MN 5537234Page S6 of S6Continuous #4 horizontal bars, provide at least (2) @ 8'-0" clear, (3) @ 9'-0" clear, & (4) @ 10'-0" clear, At contractor's option: The lowest wall horizontal bar may be omitted if (2)#4 continuous horizontal bars are placed in the footing11901 E Hennepin Ave, #201MMinneapolis, MN 55413PPhone: 612-720-4639FFax: 612-886-2966wwww.oswellec.comUnreinforced if concrete is 5000 psi or if clear height is 4" lessUnreinforced if concrete is 4000 psi or if clear height is 4" lessCast-in-place concrete foundation wall w/ #6 or equivalent vertical bars placed 1.5" from inside face, see table below for spacing2x6 minimum sill plate w/ 1/2" diameter anchor bolts w/ 7" minimum embed & 2" wide x 1/8" thick square or round countersunk washers or alternative anchor (Anchor bolt clearance between edge of both wall and sill plate is to be 2.5") (see table below for spacing) Exterior top of wall may have a brick ledge provided the stem wall formed is at least 6" thick & no more than 16" high Connection of floor members to sill plate to be per Code by others1/1/2019Clear Height88' or LessBBoltsAAlternateNANA36"(1)NANACClay99'WWall Thickness88"110"112"#4 x 2'-0" long dowels @ 72" o.c. max w/ 5" minimum embedSSandSSCCClaySSandSSCUnreinforced concrete strip footing per Code by others, elevation below slab may vary as requiredMAB/ST, MASA/FA3, FWAZ, or 1/2" diameter expansion bolts w/ 6" min embed (install in accordance with the manufacturer's recommendations)110'CClear Height and Soil TypeSSandSSCCClayVVertical Rebar SpacingNANANANA36"36"(1)NA24"36"NA36"36"(1)NA36"(2)NANANANANA72"48"72"24"48"18"36"(1)NANA72"36"60"24"36"12"48"18"SSill Anchor Spacing36"12"24"8" ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B3 2 Beam by others 6' 0" 1OPTIONAL EGRESSWINDOW HEADER(2) 1-3/4"X7-1/4"X6'VERSA LAM LVLUNEXCAVATEDSTAIRWAYFLOOR TRUSSESBY OTHERSPORCH FRAMINGBY OTHERSB2B1B3B1B35' 0" 43' 0" 48' 0" 2' 0" 22' 0" 18' 0" 9' 8"20' 0"10' 4"50' 0"30' 4"24' 0" 10' 0"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 2 Beam by others 6' 0" 1B2B1B250' 0"18' 0" ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 1 Beam by others 8' 0" 1B2B1B150' 0"18' 0" Sheet: 1 of 3DWG: Basement BeamsFile: Plan #5475-C-GLBy: Anthony EstevezDate: 6-30-16Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-1-18AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5475-C-GLD.R. HORTONBASEMENT BEAMSDESIGN = L/360BASE MODELBASEMENT BEAMSWALKOUT OPTIONLOOKOUT OPTIONDETAIL N/A Connector SummaryPlotID Qty Manuf ProductH1 19 USP THF17140ProductsPlotID Net Qty ProductLength PliesJ1 5 14" BCI® 4500s-1.8 44' 0" 1J2 4 14" BCI® 4500s-1.8 42' 0" 1J3 12 14" BCI® 4500s-1.8 36' 0" 1J4 10 14" BCI® 4500s-1.8 18' 0" 1J5 3 14" BCI® 4500s-1.8 14' 0" 1J6 1 14" BCI® 4500s-1.8 8' 0" 1B1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2B2 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B3 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B4 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B5 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 2B6 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 14' 0" 2B7 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 10' 0" 2B8 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1B9 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 6' 0" 1B10 3 1-3/4" x 24" VERSA-LAM® 2.0 3100 SP 22' 0" 3B11 1 Girder Truss by others 24' 0" 1B12 1 Beam by others 8' 0" 1B13 6 Beam by others 4' 0" 1Ca1 14 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1Pt1 1 5-1/4" x 5-1/4" VERSA-LAM® 1.7 2650 SP 12' 0" 1Pt2 1 5-1/4" x 5-1/4" VERSA-LAM® 1.7 2650 SP 10' 0" 1Pt3 3 Post by others 8' 0" 1SINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSTART FRAMING HEREJOISTS @ 19.2" OCSTAIRWAYBEAM HANGERBY TRUSS SUPPLIEROPTIONAL 6 FTWIDE WINDOW3 PLY 9-1/2" LVLPt3Pt3Pt3Pt2Pt1B2B9B6B8B9B11B10B1B12B13B5B3B13B13B13B4B13B7B13Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1J6H1J1J2J5J4J3J4H1H1H110' 4"9' 8"18' 0" 22' 0" 5' 0" 20' 0"50' 0"2' 0" 43' 0" 48' 0" 10' 0"1' 4"ProductsPlotID Net Qty Product Length PliesB1 1 Beam by others 6' 0" 1SINGLETRIMMERSSTAIRWAYB148' 0" 43' 0" Sheet: 2 of 3DWG: Upper Floor FramingFile: Plan #5475-C-GLBy: Anthony EstevezDate: 6-30-16Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.2-2-19AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5475-C-GLD.R. HORTONUPPER FLOOR FRAMINGDESIGN = L/480BASE MODELUPPER FLOOR FRAMINGDETAIL N/ASEE-THRU F.P. OPTION ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B2 1 Girder Truss by others 20' 0" 1B3 1 Beam by others 8' 0" 1B4 6 Beam by others 4' 0" 1STAIRWAYSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSB2B4B4B1B4B4B4B4B343' 0" 1' 0"6' 0" 18' 0" 18' 0" 9' 8"10' 0"20' 0"10' 4"50' 0"Sheet: 3 of 3DWG: Upper Floor HeadersFile: Plan #5475-C-GLBy: Anthony EstevezDate: 6-30-16Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5475-C-GLD.R. HORTONUPPER FLOOR HEADERSDESIGN = L/360BASE MODELUPPER FLOOR HEADERSDETAIL N/A %12;4+)*6*#0510)4172..%‹&GUETKRVKQP&CVG4GXKUKQP(GDTWCT[2TQLGEV0WODGT&CVG55JGGVUQH2TKPV0COG5KIPGF.KEGPUG0WODGT0KEM*CPUQP&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC&4*QTVQP-GPDTKFIG%QWTV.CMGXKNNG/0Ä%Ä)./QFGN/KPPGUQVC%QPUVTWEVKQP-KNOGT.CPG05WKVG2N[OQWVJ/06GNÄÄYYYJCPUQPITQWROPEQO2.#055*190.+)*6+0$#%-)4170&#4'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)4172ž5&'5+)0Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;+06'4+14$'#4+0)9#..+06'4+14010Ä$'#4+0)9#..2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'³/#+09+0&(14%'4'5+56+0)5;56'/´(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)4172ž5&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&#4&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;1760#+.'#%*64755616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. 5+/2510#(4#/+0)#0).''#%*'0&  ŒZ0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 (.11464755'5 &'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..411(64755(#56'0'&612.#6'5YF61'0#+.5"1%0#+.4+/6122.#6'5YF61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+..#&&'464755616122.#6'5YF0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y  F0#+.5'8'4;411(64755'5(#56'0'&612.#6'5Y  F61'0#+.5 5+/2510*%.+2Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+.'#%*64755616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+$$10$4#%'64755Y  F0#+.5'8'4;(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4 Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; ':6'4+14$'#4+0)9#..4'24'5'065(+)74'4  +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'&#61%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'&#55*190+06*'&'6#+.5*''65 /+0.'0)6* /+0.'0)6* +0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19 /+0.'0)6* Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'52#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#06*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;619#.-176(170&#6+1056*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;61.11-176(170&#6+105/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0722'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0%105647%62146#.(4#/'#55*190+0515$2156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.Œ5+/25106+6'0*&41&%172.'4Y'/$'&+061%10%4'6'Œ6*4'#&'&41&Y076 9#5*'4#6*1.&190'0&5+/2510*66*1.&190#0%*140#+.'&61&17$.'567&5(.1145;56'/%10%4'6'(170&#6+10$'.19#.6'40#6'*1.&190#.6'40#6'4#+5'&*1.&190%10%4'6'(170&#6+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*1900#+.'&61&17$.'567&5YŒZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*14+061%10%4'6' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'&9#...+0'$4#%'&9#...+0'$4#%'& 9#...+0' $4#%'& 9#...+0' Ä(6 Ä(6 Ä(6 $4#%'&9#...+0' Ä(6 Ä(6 Ä(6 $4#%'&9#...+0'ÄÄ5%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14&#0%'9+6*6*+5&1%7/'0656#0&#4&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä5($#0&%5Ä5($#Z567&552#%'&"1%$/+09#..5*'#6*+0)(+$'4$1#4&5*'#6*+0)Y)#.8#0+<'&411(0#+.514F0#+.514)#7)'56#2.'5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'57221465016'&15$':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#0&%5Ä952#Z567&552#%'&"1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF0#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)%#/+0+/7/Ä+0%*911&5647%674#.2#0'.%140'44'67405*#..$'2418+&'&#6$16*'0&51(#%106+07175.;Ä5*'#6*'&$4#%'&9#...+0'+0#%%14&#0%'9+6*(+)74'4+0.+'71(6*'%140'44'6740#6+'Ä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Ä%'06'4ž%#.+(140+#%140'45ž1464#&+6+10#.%140'45#4'#%%'26#$.'2418+&'&(7..*'+)*65#90$.1%-+0)567&+5&+4'%6.;$'*+0&(.#62146+101(567&5(#56'0'&61)'6*'4+0#5+/+.#4(#5*+10/#6'4+#.59#..567&5 ž14.'55 52(567&)4#&'14$'66'49#..567&5 18'4ž 52(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*':2$%1&'/+00'516#4'5+&'06+#.%1&'*#4&9#4'#.6'40#6'6#$.'5+/2510241&7%6752241&7%6#/2#/2#*46*66*66.56#564#25#/'.62/2(/56%564#25#/'56*&4,56#&4,6+6'0*&9'&)'$1.6*#4&9#4'+05#/'419/#;$'75'&+06'4%*#0)'#$.;+06*+5&1%7/'06.C[QWV%JCPIGÄÄ5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.žÄžÄ01661':%''&žÄ(#56'06122.#6'61*'#&'4Y  4195F5+0-'40#+.5"1%  Z$'#4+0)567&   Z(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0žÄ(41/%'06'41(9#..*'+)*6#54'3ž& Z51.+&$.1%-+0)4'37+4'&#65*'#6*+0),1+06  Z$'#4+0)567&5/+0 8'4+(;Y5722.+'4 5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+105 (170&#6+109#..$'.19.'0)6*1(%106+07175*'#&'4Œ#0%*14$1.6 /+0'/$'& YZZ2.#6'9#5*'40#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y  4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1% 5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55 (#56'0-+0)567&61*'#&'4Y  4195F5+0-'40#+.5"1%žÄ%106+07175.5..8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3ž& 2418+&'Z+0(+..9#..#$18'*'#&'4#54'3ž&.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&#4&0#+.+0)2418+&'(#56'0+0)1(#$18'(4#/+0)'37#.616*#6&'6#+.'&(14$4#%'&9#..2#0'.5$4#%'&9#...+0' Ä(6 Ä(6 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future Location) of Fan: X R-10/R15 X X R-20 X R-20 X R-21 X R-49 X R-49 X R-30 X R-32 X X Not applicable, all ducts located in conditioned space R-8 MECHANICAL SYSTEMS X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:80000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Cfm's Capacity continuous ventilation rate in cfms:5 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Location of duct or system: Select Type furnace room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace Combustion Air Select a Type Balanced Ventilation Capcity in CFMS: High: High: Mechanical Ventilation System 90 40%=124 70%=217 NAT GAS R-410A Cooling System Rating or Size SEER or EER 50 Output in Tons:3 Efficiency RESIDENTIAL LOAD CALC 13 Locations of Fans, describe: HEAT LOSS 62303 HEAT GAIN 23689 COOLING LOAD 30228Mineral FiberboardRigid, Extruded PolystyreneRigid, Isocynurate Appliances Model R-value0.30 PROG5042NRH67PV BA13NA036 Rheem Make-up Air Select a Type Building Envelope air Tightness:Duct system air tightness: Ceiling, flat Manufacturer 180 Interior Bryant Domestic Water Heater Heating System NAT GAS Bryant 912SC48080S17 Average U-Factor (excludes skylights and one door) U: 0.31 Heating or Cooling Ducts Outside Conditioned Spaces Bonus room over garage Describe other insulated areas Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Location of duct or system: Ceiling, vaulted Bay Windows or cantilevered areas Rim Joist (1st Floor+) Wall Per R401.3 Building Certificate. A building certificate shall be posted on or in the electrical distribution panel.9/26/17 New Construction Energy Code Compliance Certificate Name of Residential Contractor DRHorton MN License Number BC605657 Mailing Address of the Dwelling or Dwelling Unit 18892 Houston Way ChokeCherry Hill 4th Plan ID 5475 South Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Community RADON SYSTEM Interior THERMAL ENVELOPE Either/OR, See Plans For Location Other Please Describe Here Below Entire Slab Total R-Value of all Types of InsulationType: Check All That Apply Non or Not ApplicableFiberglass, BlownFiberglass, Batts Insulation Location Foam, Closed CellFoam Open Cell 5475 HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing & Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Tuesday, September 26, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5475 Plymouth, MN 55447 Page 2 Project Report General Project Information Project Title:5475 Designed By:Michael Hoium Project Date:Tuesday, September 26, 2017 Client Name:DR Horton Client City:Lakeville, MN Company Name:Sabre Plumbing & Heating Company Representative:Michael Hoium Company Address:15535 Medina Road Company City:Plymouth, MN 55447 Company Phone:763-473-2267 Company Fax:763-473-8565 Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces South Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -12.38 n/a 30%72 29.40 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:1,059 CFM Per Square ft.:0.237 Square ft. of Room Area:4,466 Square ft. Per Ton:1,773 Volume (ft³):32,167 Building Loads Total Heating Required Including Ventilation Air:62,303 Btuh 62.303 MBH Total Sensible Gain:23,689 Btuh 78 % Total Latent Gain:6,538 Btuh 22 % Total Cooling Required Including Ventilation Air:30,228 Btuh 2.52 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Tuesday, September 26, 2017, 11:57 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5475 Plymouth, MN 55447 Page 3 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.52 1,773 4,466 23,689 6,538 30,228 62,303 736 1,059 1,059 System 1 2.52 1,773 4,466 23,689 6,538 30,228 62,303 736 1,059 1,059 12x16 Ventilation 999 4,177 5,175 6,685 Supply Duct Latent 181 181 Return Duct 90 80 170 598 Humidification 6,477 Zone 1 4,466 22,601 2,101 24,702 48,544 736 1,059 1,059 12x16 1-Basement 1,382 2,694 0 2,694 14,463 219 126 126 2--5 2-Main Floor 1,382 11,547 2,101 13,648 17,104 259 541 541 5--6 3-Second Floor 1,702 8,360 0 8,360 16,977 258 392 392 4--6 Tuesday, September 26, 2017, 11:57 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5475 Plymouth, MN 55447 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 SHGC, Window and Patio Door, u-value 0.31, SHGC 0.29 431 11,630 0 6,190 6,190 11J: Door-Metal - Fiberglass Core 37.8 1,972 0 544 544 15A-15sffc-8: Wall-Basement, concrete block wall, R-15 foam board to floor, no framing, no interior finish, filled core, 8' floor depth 558 1,762 0 32 32 15A-15sffc-4: Wall-Basement, concrete block wall, R-15 foam board to floor, no framing, no interior finish, filled core, 4' floor depth 96 326 0 0 0 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 3263.2 18,454 0 2,822 2,822 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 foam board to floor, no framing, no interior finish, filled core, 8' floor depth 450 1,786 0 40 40 RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 Closed Cell Spray Foam 558 2,428 0 684 684 R49 16B-49: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles 1702 3,406 0 1,879 1,879 21A-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 1382 3,246 0 0 0 P-32 R-32: Floor-Over open crawl space or garage, Custom, R-30 Blanket insulation, 3/4" Foamboard R- 2, any cover 360 940 0 86 86 Subtotals for structure:45,950 0 12,277 12,277 People:6 1,200 1,380 2,580 Equipment:901 4,116 5,017 Lighting:1250 4,263 4,263 Ductwork:3,191 261 655 916 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 180, Summer CFM: 180 6,685 4,177 999 5,175 Humidification (Winter) 17.66 gal/day :6,477 0 0 0 Total Building Load Totals:62,303 6,538 23,689 30,228 Check Figures Total Building Supply CFM:1,059 CFM Per Square ft.:0.237 Square ft. of Room Area:4,466 Square ft. Per Ton:1,773 Volume (ft³):32,167 Building Loads Total Heating Required Including Ventilation Air:62,303 Btuh 62.303 MBH Total Sensible Gain:23,689 Btuh 78 % Total Latent Gain:6,538 Btuh 22 % Total Cooling Required Including Ventilation Air:30,228 Btuh 2.52 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Tuesday, September 26, 2017, 11:57 AM 08/21/19 X KP