Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA172916 7688 184th St W Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 3/8"=1'-0" 1 FRONT ELEVATION A Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:A1FRONT ELEVATIONAPFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154TH3/4"=1'-0" 2 COLUMN DETAILS Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 08/29/2019dmathews 3/16"=1'-0" 1 SIDE ELEVATION 3/16"=1'-0" 2 REAR ELEVATION 3/16"=1'-0" 3 SIDE ELEVATION 4 ROOF PLAN 3/16"=1'-0" Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:A2EXTERIOR ELEVATIONS, ROOF PLANAPFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154THSecure door closed until deck is constructed with a separate permit. 1/4"=1'-0" 1 LOWER LEVEL FLOOR PLAN Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:LOWER LEVEL FLOOR PLANA3APFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154THUFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. APPLY ON (3) #4 HORIZ. BARS 8" C.I.P. CONCRETE WALL VERTICAL BAR OPTIONS: #4 BARS @ 36" O.C. (GR. 60)OR #5 BARS @ 48" O.C. #4 BARS @ END & BEND OF HOOK 5'-0" HOOK OPTIONS: #5 HOOKS @ 24" O.C. OR #6 HOOKS @ 36" O.C. 8" THICK C.I.P. CONCRETE FOOTING WALL SECTION 2 S1 2" TO VERTICALBARS & HOOKS RETAINING WALL TYPE FOUNDATION WALL AT SIDE STAIRWELL WALL ONLY 1'-4" 2'-8" SLOPE GRADE AWAY FROM FOUNDATION 3"8'-4"±6"MIN. SLAB-ON-GRADE 1 2 100% GRANULAR OR GRAVEL BACKFILL w/ 6" CLAY CAP 1'-6"3'-6"12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 48" O.C. MAX. OR EQUIV. FRAME WALL ABOVE - SEE 2/S2 FOR TALL WALL REQUIREMENTS F2 F2 CONCRETE PAD FOOTING SCHEDULE MARK FOOTING SIZE REINFORCEMENT EACH WAY F1 2'-6" x 2'-6" x 0'-8"#5 BARS @ 12" O.C. F2 3'-0" x 3'-0" x 1'-0"#5 BARS @ 12" O.C. LOCATE REINFORCEMENT 3" FROM THE BOTTOM OF FOOTING F1 FOOTING MAY 12" THICK UNREINFORCED Smoke 3/8"=1'-0" 1 MAIN LEVEL FLOOR PLAN Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:MAIN LEVEL FLOOR PLANA4APFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154TH(2)9-1/2 LVL15.CUT PSL POSTS TO FIT. DO NOT BLOCK WITH WOOD PLATE MATERIAL OR CRUSHING MAY OCCUR. AT BOTTOM, PSL TO BEAR DIRECTLY ON CONCRETE. IF UNTREATED, WRAP BOTTOM w/ MEMBRANE. 44 6 10 19'-1012"± STAIR EXTERIOR TALL WOOD WALLS TO BE CONSTRUCTED AS FOLLOWS: ·(2) 2x6 LSL @ 16" O.C. TYPICAL FULL HEIGHT WALL FRAMING (BALLOON FRAMED) - IF DETERMINED TO BE EXPOSURE 'B', FRAMING MAY BE 2x6 LSL @ 12" O.C. ·PROVIDE 2x BLOCKING BETWEEN STUDS AT 10'-0" O.C. MAX. VERTICAL SPACING OVER HEIGHT OF WALL ·SHEATH WALL PER FRAMING NOTE 9 AND PROVIDE TOP OF WALL CONNECTIONS AS SHOWN FOR BRACED WALL PANELS ·TOP PLATES MAY BE 2x6 SPF #2 GRADE ·BOTTOM PLATE TO BE 2x6 SYP #2 GRADE 4 (2)9-1/2 LVL(3)11-7/8 LVL(2)9-1/2 LVL(2)9-1/2 LVL (2)9-1/2 LVL (2)2x8(2)14" LVL3.75 Shearwall 3.1 4 4 14 4 4 4 Shearwall PFH PFH FAN Smoke Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:A5UPPER LEVEL FLOOR PLANAPFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154TH3/8"=1'-0" 1 UPPER LEVEL FLOOR PLAN 4 4 4 4 4Shearwall Shearwall3 3 4 2.5 2.5 444 4 4 19'-1012"± STAIR EXTERIOR TALL WOOD WALLS TO BE CONSTRUCTED AS FOLLOWS: ·(2) 2x6 LSL @ 16" O.C. TYPICAL FULL HEIGHT WALL FRAMING (BALLOON FRAMED) - IF DETERMINED TO BE EXPOSURE 'B', FRAMING MAY BE 2x6 LSL @ 12" O.C. ·PROVIDE 2x BLOCKING BETWEEN STUDS AT 10'-0" O.C. MAX. VERTICAL SPACING OVER HEIGHT OF WALL ·SHEATH WALL PER FRAMING NOTE 9 AND PROVIDE TOP OF WALL CONNECTIONS AS SHOWN FOR BRACED WALL PANELS ·TOP PLATES MAY BE 2x6 SPF #2 GRADE ·BOTTOM PLATE TO BE 2x6 SYP #2 GRADE TEMPER -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). Smoke CO Smoke Smoke Smoke FAN FAN 1/4"=1'-0" 1 BUILDING CROSS SECTION @ FOYER / FRONT PORCH Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:A6BUILDING SECTIONSAPFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154TH1/4"=1'-0" 2 BUILDING CROSS SECTION @ FAMILY ROOM 1/4"=1'-0" 1 BUILDING CROSS SECTION @ GARAGE / STAIRS Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:A7BUILDING SECTIONSAPFG 06-28-2019 AV0124AVONLEA7688 184TH STREET WESTLAKEVILLE, MN 55044EMERSONSCHULTE1154TH 1/4"=1'-0" 4 Drawing No.Revisions / Custom OptionsCommunity:Address:City:Sheet Title:5354 Parkdale Dr. #100St. Louis Park, MN 55416763.586.7200Lot:Block:DateByThese plans are exclusive property of M/I Homes. Alldrawings and specifications are instruments ofservice copyrighted by M/I Homes, Inc. and must bereturned upon request. These plans are forconstruction purposes only. These plans may varyfrom model homes and marketing materials.Contractor to verify suitability of plans with owner.These plans are exclusive property of M/I Homes.Model:Elevation:Client:This drawing is intended to be printed at 22"x34". Drawing is half scale when printed at 11"x17" Date: Drawn By: Job #XXFinal ApprovalDateAddition:GAS FIREPLACEBP 6/18/2019 ------- 1/4"=1'-0" 3 FIREPLACE OPT. 3 - FULL HEIGHT STONE W/ BOX MANTEL 1/4"=1'-0" 2 FIREPLACE OPT. 2 - HALF HEIGHT STONE W/ WRAPPED BOX MANTEL 1/4"=1'-0" 1 FIREPLACE OPT. 1 - MANTEL SURROUND 1/2"=1'-0" 6 CANT. FIREPLACE SECTION 1/4"=1'-0" 7 CANT. FIREPLACE ELEVATIONS 1/2"=1'-0" 5 CUST. MANTEL DETAILSFIREPLACE OPT. 4 W/ COLUMNS & BOX MANTEL STANDARD FIREPLACE DETAILS 1RIM FLASHING DETAILSCALE 3/4" = 1'-0"8"XXFINAL APPROVAL SIGNATURESSCALE 1/2" = 1'-0"5FIREPLACE FRAMINGSCALE 3" = 1'-0"2PARALLEL RIM DETAIL SCALE 1" = 1'-0"3RADON GAS VENT SYSTEM -BASEMENTRADON GAS VENT SYSTEMRADON GAS VENT SYSTEM RADON GAS VENT SYSTEM4TYP. CONSTRUCTION NOTESFINAL REDLINES P.C. CHANGES LAST REVISED FINAL PREP DEC. CHANGES STANDARD CONSTRUCTION DETAILS PAGE941 NE HILLWIND ROAD, SUITE #300, FRIDLEY, MINNESOTA 55432 GENERAL NOTES: THESE ARCHITECTURAL PLANS AND THE CONSTRUCTED PURSUANT TOTHE PLANS ARE THE EXCLUSIVECOPYRIGHTED PROPERTY OF M/I HOMESAND ARE PROTECTED BY UNITED STATES COPYRIGHT LAW. ANYUNAUTHORIZED USE OF THESE PLANS IS STRICTLY PROHIBITED. COPYRIGHT D-1BASEMENT R-4 on pipe in attic FOUNDATION PLAN SHOWN FORLOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1S1REFERENCE PLANProject Number:Date:S11Sheets: ofDescriptionDateRevisionPrint Name:Signed: License Number:Trevor Axner45470Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.2ALL FOUNDATION WALLS ARETO BE PER CODE ORENGINEERED GUIDELINES16" WIDE x 8" DEEP CONCRETESTRIP FOOTING TYP. AT ALLEXTERIOR FOUNDATIONWALLS AND AT ALL INTERIORBEARING WALLS UNLESSNOTEDTHE REQUIREMENTS SHOWNDIRECTLY ABOVE ONLYAPPLY TO THEFULL BASEMENTFOUNDATIONS w/THE MORNING ROOM OPTIONTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLYTO THE OPTIONAL THIRD STALL GARAGE FOUNDATIONCOPYRIGHT HANSON GROUP, LLC 2019M/I Homes5354 Parkdale Drive, #100St. Louis Park, MN 554169.023Emerson ModelElevation AMinnesota ConstructionFebruary 1, 20197-24-19THE REQUIREMENTSSHOWN DIRECTLYABOVE ONLY APPLYTO WALKOUTFOUNDATIONSTHE REQUIREMENTSSHOWN DIRECTLYABOVE ONLY APPLYTO LOOKOUTFOUNDATIONSTHE REQUIREMENTS SHOWNDIRECTLY ABOVE ONLYAPPLY TO THELOOKOUT FOUNDATIONS w/THE MORNING ROOM OPTIONTHE REQUIREMENTS SHOWNDIRECTLY ABOVE ONLYAPPLY TO THEWALKOUT FOUNDATIONS w/THE MORNING ROOM OPTIONPLAN NOTES:1.ALL HEADERS TO BE (2) 2x10 UNLESS NOTED OTHERWISE. SEE FRAMING NOTES 1 TO 3 ON S1 FOR MORE INFO.BEARING FOR HEADERS AND BEAMS ONLY NOTED ON PLAN WHEN EXCEEDING FRAMING NOTE REQUIREMENTS.2.VERIFY FLOOR LAYOUT WITH SUPPLIER.3.REFER TO FRAMING NOTES ON S1 FOR ADDITIONAL INFORMATION.(2)2x10CONCRETE PAD FOOTING SCHEDULEMARKFOOTING SIZEREINFORCEMENT EACH WAYF12'-6" x 2'-6" x 0'-8"#5 BARS @ 12" O.C.F23'-0" x 3'-0" x 1'-0"#5 BARS @ 12" O.C.LOCATE REINFORCEMENT 3" FROM THE BOTTOM OF FOOTINGF1 FOOTING MAY 12" THICK UNREINFORCEDF2CONSTRUCT SIDESTAIR WALL ASSHOWN IN 2/S1(3) #4 HORIZ. BARS8" C.I.P. CONCRETEWALLVERTICAL BAR OPTIONS:#4 BARS @ 36" O.C. (GR. 60)OR #5 BARS @ 48" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 24" O.C. OR#6 HOOKS @ 36" O.C.8" THICK C.I.P.CONCRETE FOOTING WALL SECTION 2S12" TO VERTICALBARS & HOOKS RETAINING WALL TYPEFOUNDATION WALLAT SIDE STAIRWELL WALL ONLY1'-4"2'-8"SLOPE GRADE AWAYFROM FOUNDATION3" 8'-4"±6"MIN.SLAB-ON-GRADE12100% GRANULAROR GRAVELBACKFILLw/ 6" CLAYCAP1'-6"3'-6"12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OREQUIV.FRAME WALL ABOVE -SEE 2/S2 FOR TALLWALL REQUIREMENTSINDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ON EXTERIOR FACE IN ACCORDANCE w/ FRAMING NOTE 9.PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)EXTERIOR BEARING WALLEXTERIOR NON-BEARING WALLROOF TRUSSFASTENED TOPLATES w/ 8dTOENAILS @6" O.C.2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATES w/(3) 8d NAILS EACHINTERIOR BEARING WALLINTERIOR NON-BEARING WALLPROVIDE TRUSSDIRECTLY IN LINEw/ BRACED WALLPANEL FASTENEDTO PLATES w/ 8dTOENAILS @ 6" O.C.THESE SHEETS REPRESENT A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRE RESIDENTIAL STRUCTURE.THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WIND RESISTING ELEMENT THAT IS REQUIRED FOR THE HANSONGROUP'S DESIGN IS SHOWN ON THE STRUCTURAL DRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TO ROOF TRUSSES ABOVE, TOJOISTS/TRUSSES/BLOCKING ABOVE, AND TO JOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOTNECESSARILY REQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.NAIL LADDERTRUSS TO TOPPLATES w/ 8dNAILS @ 6" O.C.NAIL BOTTOMPLATE TOLADDER TRUSSw/ (3) 16d NAILSEVERY 16"NAIL EACH TRUSS TOTOP PLATE w/ (3) 8dTOENAILSNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEENTRUSSES NAILED TOTOP PLATES w/ (3) 8dNAILS EACHNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSSDIRECTLY IN LINEw/ BRACED WALLPANEL FASTENEDTO PLATES w/ 8dTOENAILS @ 6" O.C.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUM SHEATHING BOTH FACES WITH EITHER FASTENER OPTION LISTED INFRAMING NOTE 10, SPACED AT 4" O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.ROOF TRUSSESFASTENED TO PLATESw/ (3) 8d TOENAILS &SIMPSON H2.5 CLIP2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATES w/(3) 8d NAILS EACHNAIL EACH TRUSSTO TOP PLATES w/(3) 8d TOENAILSNAIL BOTTOMPLATE TO RIBBONBRACE / TRUSS w/(3) 16d NAILSEVERY 16"FRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(UPPER LEVEL ROOFTRUSS BEARINGWALLS ONLY)REPRESENTSFIGURER602.10.8.2(3)PROJECT SCOPEDESIGN OF THE WOOD TALL EXTERIOR WALLS, THE MAIN WINDFORCE RESISTING SYSTEM, AND THEBEAMS, HEADERS, AND SUPPORTING MEMBERS INCLUDING FOOTINGS FOR A SINGLE FAMILYRESIDENCE. CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESE DRAWINGS, STANDARDINDUSTRY PRACTICE, AND THE REQUIREMENTS OF THE CODE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED BY M/IHOMES FOR MORE INFORMATION.2.THE HANSON GROUP'S SCOPE IS LIMITED TO THE DESIGN OF THE ITEMS LISTED IN THE PROJECTSCOPE ABOVE. DESIGN OF THE REMAINING HOME INCLUDING ALL MANUFACTURER ENGINEEREDPRODUCTS ARE BY OTHERS.3.IT IS THE RESPONSIBILITY OF THE BUILDER TO PROVIDE ALL FUTURE PLAN OR FIELD CHANGES TOTHE HANSON GROUP FOR REVIEW.4.ADEQUATE SHORING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR.5.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFOREPROCEEDING WITH WORK. NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE.6.MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR.FOUNDATION NOTES1.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIRINSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE.2.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHORWITHIN 12" OF EACH END AS APPLICABLE.3.BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. PROVIDE 48" MATCHINGHOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.4.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT.5.BACKFILL BELOW EXTERIOR STOOP SLABS WITH COMPACTED GRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM).FRAMING NOTES1.ALL HEADERS ARE TO BE MINIMUM (2) 2x10 LUMBER UNLESS NOTED OTHERWISE. (2) 2x10MEMBERS SHOWN MAY BE SUBSTITUTED WITH (2) 1¾" x 7¼" LVL OR (3) 1¾" x 5½" LVL AS REQUIRED.2.ALL DIMENSION LUMBER HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE BEARING STUDAT EACH END AND TWO AT INTERMEDIATE SUPPORTS. ALL 2-PLY LVL AND GIRDER TRUSS BEAMSAND HEADERS ARE TO HAVE A MINIMUM OF TWO BEARING STUDS AT EACH END AND ATINTERMEDIATE SUPPORTS. 3-PLY LVL AND GIRDER TRUSS MEMBERS ARE TO HAVE A MINIMUM OFTHREE BEARING STUDS AT EACH END AND AT INTERMEDIATE SUPPORTS. ADDITIONAL BEARINGSTUDS ARE NOT REQUIRED FOR LVL SUBSTITUTED FOR STANDARD SAWN LUMBER. ALL BEARINGABOVE IS UNLESS NOTED OTHERWISE ON PLANS. TRUSS SUPPLIER IS TO VERIFY GIRDER TRUSSBEARING LENGTH AND SUPPORT REQUIREMENTS. BEARING ENHANCERS ARE BY THE SUPPLIER.3.ALL HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE FULL HEIGHT KING STUD AT EACHEND. EXTERIOR OPENINGS GREATER THAN SIX FEET IN WIDTH ARE TO HAVE A MINIMUM OF TWOFULL HEIGHT KING STUDS AT EACH END, EXCEPT AT TALL WALLS AS NOTED. EXTERIOR OPENINGSGREATER THAN TEN FEET IN WIDTH ARE TO HAVE A MINIMUM OF THREE FULL HEIGHT KING STUDSAT EACH END, EXCEPT AT TALL WALLS AS NOTED. FOR CONTINUOUS BEAM CONDITIONS, SPAN INDETERMINING NUMBER OF KING STUDS IS THE FULL LENGTH OF THE HEADER.4.ALL CONNECTIONS ARE TO BE MADE WITH ADEQUATE SIMPSON, USP OR EQUAL JOIST HANGERS,CLIPS, POST CAPS, AND POST BASES.5.CONNECT MULTIPLE MEMBER LVL'S TOGETHER IN ACCORDANCE WITH MANUFACTURERREQUIREMENTS.6.VERIFY DROPPED VERSUS FLUSH BEAM CONDITIONS WITH HOUSE PLANS.7.ALL OTHER FASTENERS TO BE IN ACCORDANCE CODE TABLE R602.3(1).8.ALL STUD PLIES IN BUILT UP COLUMNS AND AT INTERMEDIATE STUD FRAMING TO BE FASTENEDTO SHEATHING / GYP BOARD AS NOTED BELOW (12" O.C. MAX. AT EXTERIOR AND 16" O.C. MAX. ATINTERIOR).9.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWINGCRITERIA, U.N.O., WHICH MEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTIONR602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C. (GARAGE WALLS MAY BE 2x4 STUDS)B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C ATPANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6"SPACING.10.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWINGCRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS@ 8" O.C. MAX. OR TYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUDPENETRATION)11.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C AT PANELEDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS.12.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIPS OR EQUIVALENT AND(3) 8d TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.13.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHERWITH (8) 16d NAILS IN LAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (2)10d FACE NAILS.14.ALL BEARING POINT OR POST LOADS ARE TO BE BLOCKED SOLID TO THE FOUNDATION.15.CUT PSL POSTS TO FIT. DO NOT BLOCK WITH WOOD PLATE MATERIAL OR CRUSHING MAY OCCUR.AT BOTTOM, PSL TO BEAR DIRECTLY ON CONCRETE. IF UNTREATED, WRAP BOTTOM w/MEMBRANE.16.ENGINEERING SHOWN ASSUMES NO SILL PLATE OVERHANG AT THE TOP OF THE FOUNDATIONWALLS.17.COVERED ENTRY PORCH IS CONSIDERED BY THE HANSON GROUP TO BE A NON-ESSENTIALPRIMARILY OPEN STRUCTURE NOT PART OF THE MAIN WIND FORCE RESISTING SYSTEM. PROVIDECODE REQUIRED UPLIFT CONNECTIONS AT ALL POSTS.18.STEEL COLUMN TOP AND BOTTOM PLATES (R = 30 KIPS) ARE BY THE MANUFACTURER.19.PROVIDE 14" FULL DEPTH STIFFENERS AT THE ENDS OF ALL STEEL BEAMS.20.STEEL BEAMS ARE TO HAVE SOLID 2 x MINIMUM TOP PLATE FASTENED WITH ½" DIAMETER BOLTSSTAGGERED EACH SIDE OF WEB AT 48" ON CENTER MAX. WIDTH TO MATCH BEAM. INCREASEPLATE THICKNESS AS REQUIRED FOR TOP FLANGE HANGERS. BEAM TOP FLANGE / PLATE TO BEBRACED LATERALLY BY FLOOR SYSTEM AT 48" O.C. MAX AND AT ENDS TYP. FOR FLUSH JOISTCONNECTIONS, BLOCK WEB SPACE SOLID w/ LUMBER TIGHT BETWEEN FLANGES AND BOLTTHROUGH WEB w/ 12"Ø BOLTS AT 24" O.C. STAGGERED.MATERIALSCONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS (OR 3,000 PSI WITH AN APPROVED ADMIXTURETHATPROVIDES A WATER AND VAPOR RESISTANCE AT LEAST EQUIVALENT TO 5,000 PSI CONCRETE)CONCRETE WALLS: F'c = 3,500 PSI @ 28 DAYSREINFORCING STEEL: ASTM A615 GRADE 60 (#4 BARS MAY BE GRADE 40)BACKFILL SOIL:SAND (GROUP I) WHERE NOTED: geq = 30 PSF/FT (ACTIVE)ALLOWABLE SOILBEARING PRESSURE: 2,000 PSF (ASSUMED)WALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLSL STUDS:112" WIDTH - 1.3E OR BETTERLSL BEAMS:134" WIDTH - 1.55E OR BETTERPSL: 1.8E OR BETTERSTRUCTURAL STEEL:ANGLES/MISC - ASTM A36 (Fy = 36KSI)PIPES - ASTM A53 Gr. B (Fy = 35 KSI)TUBES - ASTM A500 Gr. B (Fy = 46 KSI)W SECTIONS - ASTM A992 (Fy = 50 KSI)LOADSROOF LIVE LOAD: 35-42 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:90 MPH EXP. CCODES2015 MINNESOTA RESIDENTIAL CODEABBREVIATIONSTYP.=TYPICALSIM.=SIMILARU.N.O.= UNLESS NOTED OTHERWISEO.C.= ON CENTER= CONTINUOUS OVEREXTERIOR NON-BEARING WALLNAIL RIM TOPPLATES w/ 8dTOENAILS @6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL EACH JOISTTO TOP PLATES w/(3) 8d TOENAILSNAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLw/ JOISTSw/ JOISTSDETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.SECTIONS SHOWN DEPICTCONNECTIONS OF BRACED WALLPANELS TO JOISTS/BLOCKING ABOVEAND TO JOISTS/BLOCKING BELOW.THESE PANELS ARE NOTNECESSARILY REQUIRED TO ALIGN,BUT MAY DEPENDING ON PLANLAYOUT.NAIL EACH JOIST TOTOP PLATE w/ (3) 8dTOENAILSNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEENJOISTS NAILED TOTOP PLATES w/ (3) 8dNAILS EACHNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOISTDIRECTLY IN LINEw/ BRACED WALLPANEL FASTENEDTO PLATES w/ 8dTOENAILS @ 6" O.C.BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTION(FLOOR JOISTS)(2) 912" LVL Plan Updates7-24-191F2(2)2x10THE REQUIREMENTS SHOWNDIRECTLY ABOVE ONLYAPPLY TO THEFULL BASEMENTFOUNDATIONS w/THE MORNING ROOM OPTIONF1BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE BRACED WALL LINE (3.5-FT)(3.5-FT) (3-FT) (6-FT)F1F1F1CONTINUEHOLDOWNSAS SHOWNIN 9/S2(6-FT)(4-FT) (3.5-FT)CONTINUEHOLDOWNSAS SHOWNIN 9/S2CONTINUEHOLDOWNSAS SHOWNIN 9/S2CONTINUEHOLDOWNSAS SHOWNIN 9/S2(4.33-FT)(8.33-FT) (7.5-FT)(3.5-FT) (3-FT)CONTINUEHOLDOWNSAS SHOWNIN 9/S2CONTINUEHOLDOWNSAS SHOWNIN 9/S2(6-FT)(6-FT)F1F1(4-FT) (4-FT)(4-FT)(2)2x10(2) 2x10 2x10 JOISTS @ 16" O.C.TYP.- VERIFY ADDITIONALJOISTS BELOW ISLAND /STONE w/ SUPPLIER PROVIDE DOUBLESTUDS AT EACH ENDOF SHEARWALL (MAYUSE BEARING/KINGSTUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENING - SEE PLAN ANDFRAMING NOTESHATCHED AREAINDICATES 716" ORTHICKER PLYWOOD/OSBEXTERIOR SHEATHINGFASTENED TO STUDS w/8d NAILS @ 4" O.C. ATPANEL EDGES & @ 12"O.C. AT INTERIORSUPPORTSTYPICAL 2x6STUDS @ 16" O.C.8'-118"±Project Number:Date:S22Sheets: ofDescriptionDateRevisionPrint Name:Signed: License Number:Trevor Axner45470Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.COPYRIGHT HANSON GROUP, LLC 2019©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.M/I Homes5354 Parkdale Drive, #100St. Louis Park, MN 554162S2FRAMING DETAIL3HOUSE SHEARWALLFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS ALONGTHIS SHEARWALL AS WELL AS ABOVEADJACENT OPENINGS(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT KING STUD - VARIES AT SIM. w/HEADERS FROM BOTH SIDES - SEE PLANAND FRAMING NOTES FOR HEADER ANDBEARING/KING STUDSHATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTS(2) 12" Ø ANCHOR BOLTS (7" MIN. EMBED)OMIT AT SIM. w/ LOOKOUT OR WALKOUTFOUNDATION BELOWTYPICAL 2x6 STUDS @ 16" O.C.PROVIDE DOUBLE STUDSAT END OF SHEARWALL -MAY USE BEARING ANDKING STUDS AS REQ'D9'-118"±SEE PLAN AND FRAMINGNOTES FOR HEADERPOST-INSTALLED HOLDOWN OPTION7S2FRAMING DETAILCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWNNAILED TO DOUBLESTUDS AND BOLTED w/12"Ø x 12" LONG SIMPSONTITEN HD SCREW-INANCHOR INTOCONCRETE12"Ø SIMPSON TITEN HDROD COUPLER w/ 8"EMBED INTO CONCRETE(MAY OMIT & EPOXYTHREADED ROD 8"DIRECTLY INTOCONCRETE)12"Ø THREADEDROD w/ NUT &WASHER ATHOLDOWN ENDSIMPSON HTT5HOLDOWN ANCHORFASTENED TODOUBLE STUDSFLOORSYSTEMCONCRETEFOUNDATIONBELOWPOST-INSTALLED HOLDOWN OPTIONRAISED ABOVE FLOOR8S2FRAMING DETAILFASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"SIMPSON STHD14RJ EMBEDDEDHOLDOWN ANCHOR AT LOCATIONSSHOWN (REFER TO 8/S2 FORALTERNATIVE POST-INSTALLED OPTION)BLOCK THROUGH FLOORSYSTEM AT HOLDOWNLOCATIONS AS REQ'DFASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"GIRDER TRUSSBY SUPPLIERTYP.19'-1012"± STAIR EXTERIOR TALL WOOD WALLS TO BECONSTRUCTED AS FOLLOWS:·(2) 2x6 LSL @ 16" O.C. TYPICAL FULL HEIGHT WALLFRAMING (BALLOON FRAMED) - IF DETERMINED TO BEEXPOSURE 'B', FRAMING MAY BE 2x6 LSL @ 12" O.C.·PROVIDE 2x BLOCKING BETWEEN STUDS AT 10'-0" O.C.MAX. VERTICAL SPACING OVER HEIGHT OF WALL·SHEATH WALL PER FRAMING NOTE 9 AND PROVIDETOP OF WALL CONNECTIONS AS SHOWN FOR BRACEDWALL PANELS·TOP PLATES MAY BE 2x6 SPF #2 GRADE·BOTTOM PLATE TO BE 2x6 SYP #2 GRADEMAIN LEVEL PLAN SHOWN FOR LOCATIONREFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1S2REFERENCE PLANUPPER LEVEL PLAN SHOWN FORLOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)2S2REFERENCE PLANPLAN NOTES:1.ALL HEADERS TO BE (2) 2x10 UNLESS NOTED OTHERWISE. SEE FRAMING NOTES 1 TO 3 ON S1 FOR MORE INFO.BEARING FOR HEADERS AND BEAMS ONLY NOTED ON PLAN WHEN EXCEEDING FRAMING NOTE REQUIREMENTS.2.VERIFY FLOOR & ROOF LAYOUT WITH SUPPLIER. PROVIDE (2) 2x6 BRG STUDS AT EACH END OF ALL GIRDER TRUSSESUNLESS NOTED OTHERWISE. TRUSS SUPPLIER TO VERIFY ADEQUATE BEARING AREA FOR TRUSS MEMBERS.3.(3) 2x10's AND (2) 912" LVL's NOTED MAY BE SUBSTITUTED w/ (2) 914" LVL's MIN.4.REFER TO FRAMING NOTES ON S1 FOR ADDITIONAL INFORMATION.BRACEDWALL LINEBRACED WALL LINELATERALLY BRACETOP OF GABLE ENDWALLS PER TRUSSSUPPLIERBRACEDWALL LINEBRACED WALL LINE(4-FT)THE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLYAPPLY TO THE OPTIONAL THIRD STALL GARAGEROOF TRUSS SPANBY SUPPLIERTYP.(2.5-FT)(2.5-FT)THE REQUIREMENTS SHOWNDIRECTLY ABOVE ONLYAPPLY TO THE MAIN LEVELMORNING ROOM OPTION(2) 14" LVL EXTENDED HEADER (2)2x10 PLAN NOTES:1.ALL HEADERS TO BE (2) 2x10 UNLESS NOTED OTHERWISE. SEE FRAMING NOTES 1 TO 3 ON S1 FOR MORE INFO.BEARING FOR HEADERS AND BEAMS ONLY NOTED ON PLAN WHEN EXCEEDING FRAMING NOTE REQUIREMENTS.2.VERIFY ROOF LAYOUT WITH SUPPLIER. PROVIDE (2) 2x6 BRG STUDS AT EACH END OF ALL GIRDER TRUSSESUNLESS NOTED OTHERWISE. TRUSS SUPPLIER TO VERIFY ADEQUATE BEARING AREA FOR TRUSS MEMBERS.3.(3) 2x10's AND (2) 912" LVL's NOTED MAY BE SUBSTITUTED w/ (2) 914" LVL's MIN.4.REFER TO FRAMING NOTES ON S1 FOR ADDITIONAL INFORMATION.BRACED WALL LINE (3) 2x6 BRGEACH END(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT) (3-FT)(3-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEFLOOR / ROOF TRUSS SPANBY SUPPLIERTYP.(2) 912" LVL(3) 1178" LVLOMIT ONE PLATEAS REQ'D TALL WALL FRAMING- SEE 2/S2(2) 912" LVL 6x6 POST w/ STANDARDPOST CAP AND BASE TYP.(2) 2x8 (2)2x10(2)2x10 (4-FT)(4-FT)(4-FT)(4-FT)(2) 912" LVL(2) 912" LVLCONSTRUCT PORTALFRAME AS SHOWN IN4/S2I-JOIST SPANBY SUPPLIERSTAIRSBY SUPPLIER(3.75-FT)CONSTRUCTSHEAR WALL ASSHOWN IN 3/S2SIM.(3.1-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)CONT. BRGFROM ABOVETYP.CONSTRUCTSHEAR WALL ASSHOWN IN 3/S2(14-FT)9.023Emerson ModelElevation AMinnesota ConstructionFebruary 1, 2019SIMPSON MSTC52STRAPS ACROSSFLOOR SYSTEMFASTENED TODOUBLE STUDSABOVE & BELOWFLOORSIMPSON STHD14HOLDOWN ANCHOREMBEDDED INTOCONCRETE &FASTENED TODOUBLE STUDS(REFER TO 7/S2 FORPOST-INSTALLEDHOLDOWN OPTION)PROVIDE 2x6BLOCKING INFLOOR SYSTEMAS REQ'DHOLDOWN TRANSFER TO LOWER LEVELAT LOOKOUT / WALKOUT OPTIONS9S2FRAMING DETAILCONCRETEFOUNDATIONBELOWREPLACE HOLDOWN w/ SIMPSON MSTC52 STRAPLAPPED ACROSS FLOOR SYSTEM w/ LOOKOUT ORWALKOUT FOUNDATION BELOW - SEE 9/S2 FORCONTINUATION OF STRAPPING TO FOUNDATIONS2FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-112"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF WALL HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 7/S2 FOR ALTERNATIVE OPTIONS)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSCONTINUOUS LVL HEADER - SEE PLAN2'-214"±PROVIDE DOUBLE STUDS AT EACHEND OF SHEARWALL (MAY USEBEARING/KING STUDS AS REQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS - SEE PLAN ANDFRAMING NOTESHATCHED AREA INDICATES 716" OR THICKERPLYWOOD/OSB EXTERIOR SHEATHING FASTENEDTO STUDS w/ 8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSTYPICAL 2x6STUDS @ 16" O.C.PERFORATED SHEARWALL5S2FRAMING DETAILFASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELS- AT VAULT OPTION, TOP OF WALLFRAMING TO MATCH INTERIORVAULT LINENOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.2'-214"±PROVIDE 14" x 4" CONCRETE SCREWS@ 16" O.C. THRU SILL PLATE INTOFOUNDATION AT THIS WALL PORTIONIN ADDITION TO ANCHOR BOLTS (NOTSHOWN FOR CLARITY)SIMPSON STHD14RJ EMBEDDEDHOLDOWN ANCHOR AT LOCATIONSSHOWN (REFER TO 8/S2 FORALTERNATIVE POST-INSTALLED OPTION)BLOCK THROUGH FLOORSYSTEM AT HOLDOWNLOCATIONS AS REQ'DOMIT CONCRETE SCREWS &INSTALL THROUGH SILL PLATE OFFOUNDATION BELOW w/ LOOKOUTOR WALKOUT CONDITIONFASTENBOTTOMPLATE w/ (3)16d NAILSEVERY 16"CONSTRUCTSHEAR WALL ASSHOWN IN 6/S2CONSTRUCTSHEAR WALL ASSHOWN IN 6/S2MIRROREDPERFORATED SHEARWALL6S2FRAMING DETAILNOTEINFO APPLIES SYMMETRICALLY ACROSS DETAILUNLESS NOTED OR SHOWN OTHERWISE.FASTEN FRAMINGABOVE AS SHOWN FORBRACED WALL PANELSFLUSH BEAM - SEE PLANSIMPSON MSTC40 STRAPCENTERED ON FLOORSHEATHINGAT SIM. w/ LOOKOUT OR WALKOUTFOUNDATION BELOW, REPLACEHOLDOWN w/ SIMPSON MSTC52 STRAPLAPPED ACROSS FLOOR SYSTEM -SEE 9/S2 FOR CONTINUATION OFSTRAPPING TO FOUNDATION7-24-19Plan Updates7-24-191(4-FT)(4-FT)BRACEDWALL LINEGIRDER TRUSSBY SUPPLIERTYP.BRACEDWALL LINEBRACEDWALL LINE(2) 912" LVL (4-FT)(4-FT)(6-FT)(4-FT)(10-FT)TALL WALL FRAMING- SEE 2/S2514 x 514 PSL EACH END -SEE FRAMING NOTE 15GIRDER TRUSSBY SUPPLIERTYP.CONTINUE REAR WALL EXTERIORSHEATHING ACROSS FULLMORNING ROOM SIDE OFSHARED WALLS NOTCHED ATLAPPED PLATE LOCATIONS ONLYCONSTRUCTPERFORATEDSHEAR WALL ASSHOWN IN 5/S2BRACEDWALL LINE(3.5-FT)(3.1-FT)(3) 1178" LVLOMIT ONE PLATEAS REQ'D BRACEDWALL LINE(5-FT)(5-FT)(3) 912" LVL TOTAL INPUT OF APPLIANCES1, THOUSANDS OF Btu/hr (kW) REQUIRED FREE AREA OF AIR-SUPPLY OPENING OR DUCT, SQUARE INCHES (sq mm) ACCEPTABLE APPROXIMATE ROUND DUCT EQUIVALENT DIAMETER2, INCH (mm) 25 (8)7 (4,500)3 (75) 50 (15)7 (4,500)3 (75) 75(23)11 (7,000)4 (100) 100 (30)14 (9,000)4 (100) 125 (37)18 (12,000)5 (125) 150 (45)22 (14,000)5 (125) 175 (53)25 (16,000)6 (150) 200 (60)29 (19,000)6 (150) 225 (68)32 (21,000)6 (150) 250 (75)36 (23,000)7 (175) 275 (83)40 (26,000)7 (175) 300 (90)43 (28,000)7 (175) 325 (98)47 (30,000)8 (200) 350 (105)50 (32,000)8 (200) 375 (113)54 (35,000)8 (200) 400 (120)58 (37,000)9 (225) 1. For total inputs falling between listed capacities, use next largest listed input. 2. If flexible duct is used, increase the duct diameter by one inch. * *Flexible duct shall be stretched with minimal sags. TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 Btu/hr BTU Amount for Non-direct vent appliances_____________________ 1 2 3 4 5 6 2 Conditioned space1 (in sq. ft.) Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130-65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113 1. Conditioned space includes the basement and conditioned crawl spaces. 2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2 R403.5.2 Total Ventilation rate. The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and square footage of conditioned space, including the basement and conditioned crawl spaces. For the purposes of Table R403.5.2 and Section R403.5.3, the following applies: a. Equation R403.5.2 Total ventilation rate: Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1)) b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2 Amount Total _________________________ Amount Continuous____________________ TABLE R403.5.2 NUMBER OF BEDROOMS VENTILATION REQUIREMENTS ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD 1. Use the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) clothes dryer b) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) c) 80% of next largest exhaust rating (cfm):not applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm): [2a+2b+2c] 3. Makeup Air Requirement a) Total Exhaust Capacity (from above) b) Estimated House Infiltration (from above) Makeup Air Quality (cfm): [3a - 3b] (if value is negative, no makeup air is needed 4. For Makeup Air Opening Sizing, refer to Table 501.4.2. A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units Choose Which Applies TYPE OF OPENING ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD PASSIVE MAKEUP AIR OPENING DUCT DIAMETERE,F,G OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches) Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening with motorized damper 318-419 196-258 136-179 84-110 9 Passive opening with motorized damper 420-539 259-332 180-230 111-142 10 Passive opening with motorized damper 540-679 333-419 231-290 143-179 11 Powered makeup airH >679 >419 >290 >179 Not applicable A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combution appliace information: Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: Btu/hr (Not fan Assisted) & Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: Btu/hr ( Not fan Assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 Step 3: Determine air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RVFA: ft3 Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3 Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = - = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in 2 = in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. CAOA = IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Known Air Infiltration Rate (KAIR) Method (ft3) Input Rating Standard Method Fan Assisted Non-Fan-Assisted (Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8,625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,763 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 08/01/19 X KP