Loading...
HomeMy WebLinkAboutLA173771 8378 200th St W Permit Pack2nd RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: MAIN FLOOR1' -8 1/4"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"8:12VINYLSHAKESALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDE TRIMTYP. @ FRONTCULTURED STONEW/ CONCRETE CAPADDRESSSTONE12824" SQUARE CULTUREDSTONE BASE W/TAPERED CEDAR COLUMN3' - 6"1' - 6"4' - 0"124(2)8x8x36" CORBELFRONT470 SQ. FT. TOTAL94 SQ. FT. STONE20% COVERAGEGARAGE PLATE HEIGHT10' - 9 3/8"VINYL LAPSIDINGDORMER PLATE16' -7 3/8"4:12DORMER PLATE HEIGHT5' - 10"51248:121284:121288:12VINYL SIDING& CORNERS TYP.8:12ALUMINUM SOFFIT& FASCIA TYP.1282x10LEDGER1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012RIGHT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:05 AMTHE BILLINGER RESIDENCEA-201DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'25721/8" = 1'-0"A-2013LEFT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATIONSHEET INDEXSHEET NAME SHEET NUMBERELEVATIONS A-201FOUNDATION A-401LOWER FLOOR A-402MAIN FLOOR A-403SECTIONS A-501WINDOW SCHEDULE/ ROOF A-502Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode09/20/2019dmathews 5' - 2"45' - 8"12' - 0"6' - 10"5' - 4"1' - 4 1/2"9' - 3" M.O.0' - 10 1/2"1' - 10 1/2"16' - 3" M.O.1' - 10 1/2"*DIMENSIONS ARE TO EXTERIOROF CONCRETE, NOT INSULATION18' - 10"31' - 6"19' - 4"11' - 6"20' - 0"8' - 6"10' - 10"25' - 8"8' - 0"12' - 0"18' - 10"5' - 0"0' - 4"0' - 4"0' - 4"24' - 6"2' - 0"22' - 6"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2'-10"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.50' - 10"6' - 6"2' - 0"2' - 0"4' - 10"1' - 0"1' - 0"STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE0' - 2"50' - 10"30' - 2"29' - 6"54' - 0"35' - 2"29' - 10"54' - 0"23' - 8"6' - 2"13' - 4"2' - 7 1/4"4' - 5 1/2"9' - 9 1/4"10' - 10 3/4"16' - 10 1/4"17' - 11"3' - 2 1/4"14' - 0 1/2"16' - 8 1/2":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:05 AMTHE BILLINGER RESIDENCEA-401DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'25721/4" = 1'-0"A-4011FOUNDATION PLAN UP 16R5' - 0"46' - 0"UNEXCAVATEDUNEXCAVATEDBEDROOM #3FINISHED.BEDROOM #4FINISHED.SUMPFURNACEFLOORDRAINW. H.MECHANICAL /STORAGEBATHFINISHED.FAMILYROOMFINISHED.12' - 0"6' - 8"5' - 4"30' - 0"18" FLOOR TRUSSESPER MFG. SPACING*SET FOUNDATION WALLS IN2" -OUTSIDE OF FOUNDATIONINSULATION TO ALIGN WITHOUTSIDE OF SHEATHING18' - 8"35' - 4"54' - 0"31' - 6"19' - 6"11' - 6"20' - 0"8' - 6"11' - 0"25' - 8"8' - 4"18' - 8"5' - 0"0' - 6"0' - 6"54' - 0"24' - 6"29' - 6"2' - 0"22' - 6"30' - 4"INSULATE BETWEENWALL & SLAB51' - 0"18" FLOOR TRUSSESPER MFG. SPACINGR & SHSMOKEDET.46' - 6"2' - 0"2' - 0"4' - 8"1' - 0"1' - 0"2'-6" VANITY24" CANT. ABOVE30" CANT.ABOVE2/8 x 6/8AIR EX.2/8 x 6/8THEATERROOMFINISHED.2/6 x 6/8LINEN5/0 x 6/8 BFSMOKEDET.SMOKEDET.CO DET.46/0 x 6/8SLIDERSTORAGE6' - 4"23' - 8"2/4 x 6/8LAUNDRYTUB7' - 0 1/8"15' - 5 7/8"9' - 11 3/4"7' - 6 1/4"6' - 0"STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE0' - 6"0' - 6"30' - 4"15' - 10"12' - 6"17' - 8"10' - 2"4' - 0"16' - 2"11' - 8"5' - 4 1/2"11' - 5 3/4"17' - 5 3/4"11' - 8"2' - 6"2' - 6"11' - 10 1/4"17' - 5 3/4"18' - 4"2' - 4"2' - 4"7' - 4"51' - 0"FLOOR GIRDER2-2x10 FLUSHRAILING4' - 2"2-9 1/2" LVL W/2 TRIMMERS2-9 1/2" LVL W/2 TRIMMERS2-9 1/2" LVL W/2 TRIMMERS42-9 1/2" LVL W/2 TRIMMERS5' F.G. TUB/SHWR6' - 0" B.W.P.6' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.2/6 x 6/816' - 10"13' - 4"1/6 x 6/82/6 x 6/8HALLFINISHED.5/0 x 6/8 BFR & SH2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2x61/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:05 AMTHE BILLINGER RESIDENCEA-402DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'2572CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESFANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. DN 3RDN 3RDN 16R31' - 6"19' - 6"5' - 0"46' - 0"51' - 0"11' - 6"20' - 0"7' - 6"12' - 0"56' - 0"56' - 0"37' - 0"19' - 0"13' - 0"6' - 0"5' - 0"32' - 0"51' - 0"QUEEN3/0 x 6/8 W/12" D.S. SLBEDROOM #2OWNER'SSUITETRAY VAULT.BATHVINYL.BATHR & SHHALLKING30" RANGE36" REFSINKKITCHENWOOD FLR..DININGWOOD FLR..LIVING ROOMCARPET.6/0 x 6/8SLIDER1' - 6"9' - 0"1' - 0"2' - 0"16' - 0"2' - 0"9' x 7' O.H.GARAGEDOOR16' x 7' O.H.GARAGEDOOR4' - 0"2/8 x 6/8 FIRERATED5' - 0"23' - 6"2' - 6"8' - 0"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR2x4 EXTERIOR WALLSATTICACCESSCO DET.SMOKEDET.SMOKEDET.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2-2x1024" SQUARE CULTUREDSTONE BASE W/TAPERED CEDAR COLUMN24' - 6"31' - 6"22' - 6"2' - 0"2/6 x 6/8SMOKEDET.4CLOSET4' - 0"3' - 0"4' - 0"7' - 0"9' - 1"11' - 0"32-2x12 W/ 2 TRIMMERS3' VANITYWASHERDRYER2/4 x 6/8 PKTPANTRY16" SH.9' - 9"22' - 3"5' F.G. TUB/SHWRR & SH2/4 x 6/82/4 x 6/82/4 x 6/82/4 x 6/8R & SH2/6 x 6/82/4 x 6/8MUD /LAUNDRYVINYL FLR..FOYERWOOD FLR..2/6 x 6/8GARAGESTOOPCONCRETE.TYP.2' - 0"RAILINGR & SH42" BASE& UPPER2/8 x 6/8 PKTBENCH2x62/4 OPG.TILESHOWER2/4 x 6/8LINEN2' LINEN6' VANITY2/4 x 6/8R & SHCLOSET7' - 0 1/8"22' - 11 1/8"10' - 0 3/4"6' - 0"1' - 0"GIRDER TRUSS21' - 4"2' - 2"25' - 8 7/8"6' - 3 1/8"32' - 0"17' - 4"11' - 0"17' - 8"18' - 2"4' - 0"9' - 10"11' - 8 3/4"2' - 8 1/2"2' - 9"9' - 2"19' - 7 3/4"2x68' - 0"7' - 0"3' - 1"2' - 5"0' - 10 3/4"3' - 10"20' - 9 1/4"8' - 10"6' - 2"4' - 0"0' - 10"8' - 4"3' - 10"2' - 4"6' - 0"1' - 8"4' - 0"SMOKEDET.2-9 1/2" LVL2-9 1/2" LVL2-2x102-9 1/2" LVL2-2x102-2x12DW47' - 0" BRACED WALL LINE SPACING33' - 0" BRACED WALL LINE SPACING21' - 0" BRACED WALL LINE SPACING54' - 0" BRACED WALL LINE SPACING27' - 6" BRACED WALL LINE SPACING19' - 6" BRACED WALL LINE SPACING4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.PFH BRACED WALL PANELS3' - 0" B.W.P.6' - 0"6' - 0"3' - 0" B.W.P.3' - 0" B.W.P.PFH BRACED WALL PANEL3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.GAS F.P.5' - 0"1422' - 0"8' - 8 1/8"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:06 AMTHE BILLINGER RESIDENCEA-403DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'2572CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*SET FOUNDATION WALLS IN2" -OUTSIDE OF FOUNDATIONINSULATION TO ALIGN WITHOUTSIDE OF SHEATHING2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS3/4" SUBFLOORFLOOR TRUSSESTO BE MFG. W/1 1/2" CANTILEVER2x8 SILL PLATE, ANCHORBOLTS PER CODEPOUREDFOUNDATION WALL2x6 EXTERIOR WALLWITH 1/2" OSBSHEATHING2" FOAMINSULATION2x6 EXTERIOR WALLWITH 1/2" OSBSHEATHING2" FOAMINSULATION2x4 RIBBON ATTACHED TOTOP & BOTTOM CHORDS USING0.135" x 3.50" BOX NAILS @ 6"O.C. THROUGHOUT & 1 NAILINTO EACH WEB3/4" SUBFLOOR2x8 SILL PLATE, ANCHORBOLTS PER CODEPOUREDFOUNDATION WALL4x2 GABLE TRUSSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x8 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*SET FOUNDATION WALLS IN2" -OUTSIDE OF FOUNDATIONINSULATION TO ALIGN WITHOUTSIDE OF SHEATHING6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATIONANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESFLOOR SYSTEM,VERIFY W/ PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" FOAMBOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 6"POUREDFOUNDATIONWALLANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ ROLL SILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONFLASHING AS REQ'D10" POUREDFND. WALLSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 8"0' - 2"CONCRETE STOOPTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:06 AMTHE BILLINGER RESIDENCEA-501DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'25723/8" = 1'-0"A-5012TYP. WALL SECTION1/2" = 1'-0"A-5013BEARING WALL SECTION1/2" = 1'-0"A-5014FLOOR TRUSS DETAILS1/2" = 1'-0"A-5015TYP. LOOKOUT SECTION1/2" = 1'-0"A-5016TYP. WALKOUT SECTION1/2" = 1'-0"A-5011TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5017TYP. HOUSE/STOOP WALL FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL4:12 & 8:12 ROOF PITCH TYP. W/STANDARD ENERGY HEELS18" OVERHANGS & 12" RAKES TYP.3' - 6"4:1210' - 0"13' - 0"4:128' - 0"2' - 0"SET HEELS TOMATCH HOUSE/GARAGE FASCIA2' - 0"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:GARAGE:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES401 OAK STREET - SUITE AFARMINGTON, MN 55024PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:8/8/2019 9:35:06 AMTHE BILLINGER RESIDENCEA-502DDB12215251047(721)8.6.19 CB9'-1 1/8"8'-4'25723/8" = 1'-0"A-5021METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/8" = 1'-0"A-5022ROOF PLANWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL UNIT COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 THERMO-TECH CLASSIC SERIES TS 4842 1 4' - 0 1/4" 3' - 6 1/4" 6' - 10"2 THERMO-TECH CLASSIC SERIES 6024 FIXED 1 4' - 11 1/2" 1' - 11 1/2" 8' - 0"3 THERMO-TECH CLASSIC SERIES TDH 3660-2 1 5' - 11 3/4" 5' - 0 1/4" 6' - 10"4 THERMO-TECH CLASSIC SERIES TDH 4060-2 E 5 6' - 7 3/4" 5' - 0 1/4" 6' - 10"5 THERMO-TECH CLASSIC SERIES TA-3624 -2 FIXED 1 5' - 11 3/4" 2' - 0 1/4" 4' - 10"3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:R-4 on pipe in attic 09/16/19 X KP