Loading...
HomeMy WebLinkAboutLA173946 - 17862 Essex Lane Permit Pack2 1 Pheasant Run 4th RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 09/26/2019dmathews Secure door closed until deck is constructed with a separate permit. G.T. (2)9-1/2" LSL 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP PFH PFH 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 8' LIB8' LIB8' LIB UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. 5.17' LIB 5.17' LIB 5.17' LIB 5.17' LIB 4' WSP 4' WSP 8' LIB 8' LIB 8' LIB 5.17' LIB 5.17' LIB 5.17' LIB5.17' LIB5.17' LIB -Min. 15" clearance to anyobstruction from center of W.C., 24" in front(typ). Smoke LOWER LEVEL G.T. BBO B7 (2 -ply) H6 (2 -ply) H8 (2 -ply) H8 (2 -ply) H7 (3 -ply) H3 (2 -ply) H2 (2 -ply)H1 (2 -ply) H1 (2 -ply) PSPS PS PSPSPSPS PS PS BASEMENT BEAMS LVL/LSL Label Description Width Depth Qty Plies Pcs Length H3 LP-LSL 1.55E 1.75 9.5 1 2 2 18-0-0 H2 LP-LSL 1.55E 1.75 9.5 1 2 2 8-0-0 H1 LP-LSL 1.55E 1.75 9.5 2 2 4 6-0-0 Lumber Label Description Width Depth Qty Plies Pcs Length B7 S-P-F #2 1.5 9.25 1 2 2 10-0-0 H6 S-P-F #2 1.5 9.25 1 2 2 7-0-0 B6 S-P-F #2 1.5 9.25 2 2 4 6-0-0 H4 S-P-F #2 1.5 9.25 1 2 2 4-0-0 H8 S-P-F #2 1.5 9.25 2 2 4 3-0-0 H7 S-P-F #2 1.5 11.25 1 3 3 10-0-0 Legend PS Point Load Support 2x6 PLATE Wall Opening LP-LSL 1.55E 1.75 X 9.5 (Dropped) S-P-F #2 1.5 X 9.25 (Dropped) S-P-F #2 1.5 X 9.25 S-P-F #2 1.5 X 11.25 (Dropped) 1.75 X 18 BASEMENT BEAMS This drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise. Important Notes Review Manufacturers' installation guide for additional structural details where necessary. Do Not cut or notch top or bottom floanges of joists to provide clearance for plumbing fixtures. Offset and/or install additional joists to provide clearance. All dimensional stock "Dropped headers" by others All Steel beams, angles and columns by others , Version 18.80.245 Powered by iStructThis layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them NOTE: USE WEBSTIFFENERS WALL SUPPORTED BY F.T. BELOW G.T. G.T. G.T. I-JOIST BLOCKINGDN MAIN FLOOR: 11-7/8" LP 20PLUS 19.2" O.C. NOTE: ALIGN JOISTS TO ALLOW FOR PLUMBING AND MECHANICAL INSTALLATION 10 J1 @ 19.2"2 X J3 6 J2 @ 19.2" H6 (2 -ply) H5 (2 -ply) H4 (2 -ply)H2 (2 -ply) H1 (2 -ply) R1R1 R1 18 x H1 (MIU2.56/11 (Max)) MAIN FLOOR I Joist Label Description Width Depth Qty Plies Pcs Length J3 LPI 20Plus 2.5 11.875 2 20-0-0 J2 LPI 20Plus 2.5 11.875 6 18-0-0 J1 LPI 20Plus 2.5 11.875 10 16-0-0 Blocking Label Description Width Depth Qty Plies Pcs Length BLK1 LPI 20 Plus 2.5 11.875 LinFt Varies 13-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 11.875 1.125 11.875 6 12 LVL/LSL Label Description Width Depth Qty Plies Pcs Length H2 LP-LSL 1.55E 1.75 9.5 1 2 2 8-0-0 H1 LP-LSL 1.55E 1.75 9.5 1 2 2 6-0-0 B5 LP-LSL 1.55E 1.75 11.875 2 6-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H1 18 MIU2.56/11 (Max) 20 16d 6 10dx1 1/2 Lumber Label Description Width Depth Qty Plies Pcs Length H6 S-P-F #2 1.5 9.25 1 2 2 7-0-0 H5 S-P-F #2 1.5 9.25 2 2 4 6-0-0 H4 S-P-F #2 1.5 9.25 3 2 6 4-0-0 Legend PS Point Load Support 2x6 PLATE Wall Opening LP APA Rated OSB 1.125 X 11.875 LPI 20Plus 11.875 LP-LSL 1.55E 1.75 X 9.5 (Dropped) LP-LSL 1.55E 1.75 X 11.875 S-P-F #2 1.5 X 9.25 (Dropped) 1.75 X 11.875 MAIN FLOOR Design Method ASD Building CodeIBC/IRC 2015 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/240 This drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise. Important Notes Review Manufacturers' installation guide for additional structural details where necessary. Do Not cut or notch top or bottom floanges of joists to provide clearance for plumbing fixtures. Offset and/or install additional joists to provide clearance. All dimensional stock "Dropped headers" by others All Steel beams, angles and columns by others , Version 18.80.245 Powered by iStructThis layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them Date Certificate Post x Passive (No Fan ) Active (With fan and monometer or other system monitoring device ) Location (or future location) of Fan: Other Please Describe Here x R-15 x x R-20 x x R-20 x x 19+5 x x R-49 x R-49 x R-38 x R-38+5 x x X Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:44,000 Capacity in Gallons:Other, describe: AFUE or HSPF%95% Cfm's " round duct OR " metal duct Not required per mech. code X Passive x Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " Flex " metal duct City Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Natural Gas Domestic Water Heater Heating System Rating or Size Appliances R10 Rigid Exterior, R10 Int closed cell R10 Rigid Exterior, R10 Int closed cell Wall Ceiling, vaulted Ceiling, flat Lennox Heating or Cooling Ducts Outside Conditioned Spaces Electric Rim Joist (2nd Floor+) Bay Windows or cantilevered areas Perimeter of Slab on Grade Foundation Wall Below Entire Slab Fi b e r g l a s s , B a t t s Brandl Anderson Homes BC604388 Mailing Address of the Dwelling or Dwelling Unit Name of Residential Contractor 17862 Essex Lane MN License Number Lakeville Fo a m O p e n C e l l Type: Check All That Apply Fo a m , C l o s e d C e l l THERMAL ENVELOPE RADON CONTROL SYSTEM To t a l R - V a l u e o f a l l T y p e s o f In s u l a t i o n Insulation Location Rim Joist (1st Floor) R-5 where required Floors over unconditioned area Describe other insulated areas Attic Fi b e r g l a s s , B l o w n No n o r N o t A p p l i c a b l e Rig i d , I s o c y n u r a t e Rig i d , E x t r u d e d P o l y s t y r e n e Min e r a l F i b e r b o a r d R5 Exterior, R19 Batts Cooling System Make-up Air Select a Type R-value R-80.30 MECHANICAL SYSTEMS Duct system air tightness: Windows & Doors 0.30 Average U-Factor (excludes skylights and one door ) U: Building envelope air tightness: 50 13ACXN018 Heating Gain 11869 Output in Tons:1.5 Location of duct or system:13 Cooling Load 15,605 SEER /EER Manufacturer Model Residential Load Calculation Natural Gas Fuel Type Solar Heat Gain Coefficient (SHGC): Lennox ML195UH045 Heating Loss 36618 Efficiency Location of duct or system: Balanced Ventilation capacity in cfms: Total ventilation (intermittent + continuous) rate in cfms: MECHANICAL VENTILATION SYSTEM Combustion Air Select a Type High: Capacity continuous ventilation rate in cfms: High: 15066Heat Recover Ventilator (HRV) Capacity in cfms: Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Energy Recover Ventilator (ERV) Capacity in cfms: 000000Builders Associaton of Minnesota version 101014 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 704 704 .23 .23 .77 .77 10.3 3.6 NR 2938 441 441 135 135 135 68 09/17/19 X KP