Loading...
HomeMy WebLinkAboutLA174125 17940 Evening Lane Permit PackCANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 10/01/2019dmathews Secure door closed until deck is constructed with a separate permit. 4' WSP4' WSP4' WSP UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. 4' WSP 4' WSP 4' WSP 3' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP PFHPFH 4' WSP2.25' WSP 4' CS-WSP 4' CS-WSP 2.75' CS-WSP 4' CS-WSP 2.33' CS-WSP 3' WSP 8' LIB 8' LIB 8' LIB 4' WSP 4' WSP 2.75' WSP 8' LIB 8' LIB -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). BASEMENT BEAMS F.T. B9 (2 -ply) H1 (2 -ply)H1 (2 -ply) PSPSPSPSPS PSPSPSPS PSPS PS PSPSPSPS PS PS PSPSPSPS PS BASEMENT BEAMS LVL/LSL Label Description Width Depth Qty Plies Pcs Length H1 LP-LSL 1.55E 1.75 9.5 2 2 4 6-0-0 B9 LP-LVL 2900Fb-2.0E 1.75 11.875 1 2 2 20-0-0 Legend PS Point Load Support Load from Above 2x6 PLATE Wall Opening LP-LSL 1.55E 1.75 X 9.5 (Dropped) LP-LVL 2900Fb-2.0E 1.75 X 11.875 (Dropped) 1.75 X 18 BASEMENT BEAMS This drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise. Important Notes Review Manufacturers' installation guide for additional structural details where necessary. Do Not cut or notch top or bottom floanges of joists to provide clearance for plumbing fixtures. Offset and/or install additional joists to provide clearance. All dimensional stock "Dropped headers" by others All Steel beams, angles and columns by others , Version 18.80.245 Powered by iStructThis layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 9.5 KIPS 9.5 KIPS DN NOTE: ALIGN JOISTS TO ALLOW FOR PLUMBING AND MECHANICAL INSTALLATION START JOIST RUN UPPER FLOOR: 11-7/8" LP20-PLUS 19.2" O.C. I-JOIST BLOCKING 7 J3 @ 19.2"6 J1 @ 19.2" 9 J4 @ 19.2"13 J2 @ 19.2" B3 (2 -ply) B7 (3 -ply) B6 (2 -ply) H5 (2 -ply) H3 (2 -ply) H2 (2 -ply) H1 (2 -ply) H10 (3 -ply) H9 (3 -ply) H4 (3 -ply) R1 R1 R1 R1 R1 9 x H3 (IUS2.56/11.88 (Min)) 7 X H3H1 11 x H3 (IUS2.56/11.88 (Min)) UPPER FLOOR I Joist Label Description Width Depth Qty Plies Pcs Length J4 LPI 20Plus 2.5 11.875 9 34-0-0 J3 LPI 20Plus 2.5 11.875 7 20-0-0 J2 LPI 20Plus 2.5 11.875 13 16-0-0 J1 LPI 20Plus 2.5 11.875 7 14-0-0 Blocking Label Description Width Depth Qty Plies Pcs Length BLK1 LPI 20 Plus 2.5 11.875 LinFt Varies 10-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 11.875 1.125 11.875 10 12 LVL/LSL Label Description Width Depth Qty Plies Pcs Length B3 LP-LSL 1.55E 1.75 7.25 1 2 2 22-0-0 H3 LP-LSL 1.55E 1.75 9.5 1 2 2 10-0-0 H2 LP-LSL 1.55E 1.75 9.5 1 2 2 8-0-0 H1 LP-LSL 1.55E 1.75 9.5 1 2 2 6-0-0 B6 LP-LSL 1.55E 1.75 11.875 1 2 2 20-0-0 B5 LP-LSL 1.55E 1.75 11.875 1 2 2 16-0-0 B4 LP-LSL 1.55E 1.75 11.875 1 8-0-0 B7 LP-LVL 2900Fb-2.0E 1.75 14 1 3 3 14-0-0 H4 LP-LVL 2900Fb-2.0E 1.75 16 1 3 3 18-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H1 1 HU11 (Min)22 16d 6 10dx1 1/2 H2 1 HHGU5.50- SDS 44 SDS 1/4x2 1/2 28 SDS 1/4x2 1/2 H3 27 IUS2.56/11.88 (Min) 10 10d Lumber Label Description Width Depth Qty Plies Pcs Length H10 S-P-F #2 1.5 9.25 1 3 3 11-0-0 H9 S-P-F #2 1.5 9.25 1 3 3 7-0-0 H5 S-P-F #2 1.5 9.25 4 2 8 4-0-0 Legend PS Point Load Support Load from Above 2x6 PLATE Wall Opening LP APA Rated OSB 1.125 X 11.875 LPI 20Plus 11.875 LP-LSL 1.55E 1.75 X 7.25 LP-LSL 1.55E 1.75 X 9.5 (Dropped) LP-LSL 1.55E 1.75 X 11.875 LP-LVL 2900Fb-2.0E 1.75 X 14 LP-LVL 2900Fb-2.0E 1.75 X 16 (Dropped) S-P-F #2 1.5 X 9.25 (Dropped) 1.75 X 11.875 UPPER FLOOR Design Method ASD Building CodeIBC/IRC 2015 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/240 This drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise. Important Notes Review Manufacturers' installation guide for additional structural details where necessary. Do Not cut or notch top or bottom floanges of joists to provide clearance for plumbing fixtures. Offset and/or install additional joists to provide clearance. All dimensional stock "Dropped headers" by others All Steel beams, angles and columns by others , Version 18.80.245 Powered by iStructThis layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them UPPER FLOOR HEADERS G.T. H6 (2 -ply) H5 (2 -ply) H3 (2 -ply) H9 (3 -ply) H8 (3 -ply) 2ND FLOOR HEADERS LVL/LSL Label Description Width Depth Qty Plies Pcs Length H3 LP-LSL 1.55E 1.75 9.5 1 2 2 10-0-0 Lumber Label Description Width Depth Qty Plies Pcs Length H9 S-P-F #2 1.5 9.25 1 3 3 7-0-0 H6 S-P-F #2 1.5 9.25 1 2 2 7-0-0 H8 S-P-F #2 1.5 9.25 1 3 3 6-0-0 H5 S-P-F #2 1.5 9.25 1 2 2 4-0-0 Legend PS Point Load Support Load from Above 2x6 PLATE Wall Opening LP-LSL 1.55E 1.75 X 9.5 (Dropped) S-P-F #2 1.5 X 9.25 (Dropped) 1.75 X 11.875 2ND FLOOR HEADERS This drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise. Important Notes Review Manufacturers' installation guide for additional structural details where necessary. Do Not cut or notch top or bottom floanges of joists to provide clearance for plumbing fixtures. Offset and/or install additional joists to provide clearance. All dimensional stock "Dropped headers" by others All Steel beams, angles and columns by others , Version 18.80.245 Powered by iStructThis layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them Date Certificate Post x Passive (No Fan ) Active (With fan and monometer or other system monitoring device ) Location (or future location) of Fan: Other Please Describe Here x R-15 x x R-20 x x R-20 x x 19+5 x x R-49 x R-49 x R-38 x R-38+5 x x Not applicable, all ducts located in conditioned space X x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: AFUE or HSPF%95% Cfm's " round duct OR " metal duct Not required per mech. code X Passive x Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " Flex " metal duct City Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Natural Gas Domestic Water Heater Heating System Rating or Size Appliances R10 Rigid Exterior, R10 Int closed cell R10 Rigid Exterior, R10 Int closed cell Wall Ceiling, vaulted Ceiling, flat Lennox Heating or Cooling Ducts Outside Conditioned Spaces Electric Rim Joist (2nd Floor+) Bay Windows or cantilevered areas Perimeter of Slab on Grade Foundation Wall Below Entire Slab Fiberglass, BattsBrandl Anderson Homes BC604388 Mailing Address of the Dwelling or Dwelling Unit Name of Residential Contractor 17940 Evening Lane MN License Number Lakeville Foam Open CellType: Check All That Apply Foam, Closed CellTHERMAL ENVELOPE RADON CONTROL SYSTEM Total R-Value of all Types of Insulation Insulation Location Rim Joist (1st Floor) R-5 where required Floors over unconditioned area Describe other insulated areas Attic Fiberglass, BlownNon or Not ApplicableRigid, IsocynurateRigid, Extruded PolystyreneMineral FiberboardR5 Exterior, R19 Batts Cooling System Make-up Air Select a Type R-value R-80.30 MECHANICAL SYSTEMS Duct system air tightness: Windows & Doors 0.30 Average U-Factor (excludes skylights and one door ) U: Building envelope air tightness: 50 13ACXN018 Heating Gain 11117 Output in Tons:1.5 Location of duct or system:13 Cooling Load 14,856 SEER /EER Manufacturer Model Residential Load Calculation Natural Gas Fuel Type Solar Heat Gain Coefficient (SHGC): Lennox ML195UH045XP Heating Loss 38745 Efficiency Location of duct or system: Balanced Ventilation capacity in cfms: Total ventilation (intermittent + continuous) rate in cfms: MECHANICAL VENTILATION SYSTEM Combustion Air Select a Type High: Capacity continuous ventilation rate in cfms: High: 19282Heat Recover Ventilator (HRV) Capacity in cfms: Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Energy Recover Ventilator (ERV) Capacity in cfms: 000000Builders Associaton of Minnesota version 101014 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 1936 1936 .64 .64 .36 .36 4.8 2.5 375 375 NR 3154 473 473 240 160 80 09/19/19 X KP 9/4/19 1 Mathews, David From:Matt Olson <molson@brandlanderson.com> Sent:Wednesday, September 4, 2019 12:56 PM To:Lori McDonough; Amanda Wheeler Subject:FW: Brandl/Anderson Lot Permit Transfers Attachments:MPCA_L1B1_Knob Hill.pdf; MPCA_L4B1_Knob Hill.pdf; MPCA_L3B1_Knob Hill.pdf; MPCA_L7B2_Knob Hill.pdf Follow Up Flag:Follow up Flag Status:Flagged The attached MPCA permits are signed. Thanks, Matt From: Amy Skillestad <amy@kjwalk.com> Sent: Wednesday, September 4, 2019 12:15 PM To: MN_MPCA_CSW <csw.pca@state.mn.us> Cc: Matt Olson <molson@brandlanderson.com> Subject: Brandl/Anderson Lot Permit Transfers Lot 1 Block 1 Knob Hill Lot 3 Block 1 Knob Hill Lot 4 Block 1 Knob Hill Lot 7 Block 2 Knob Hill