HomeMy WebLinkAbout17325 Eastwood Ave Survey(9
2
9
.
0
)
E
A
S
T
W
O
O
D
A
V
E
N
U
E
1
2
.
1
3
25.
3
3
R
:
9
3
0
.
8
1
R
:
9
3
0
.
4
8
O
S
1
2
.
3
0
H
U
B
=
9
2
4
.
3
1
O
S
2
2
.
4
3
H
U
B
=
9
2
3
.
6
5
O
S
2
6
.
4
1
H
U
B
=
9
2
9
.
3
4
F
D
I
P
#
4
7
4
8
1
R
:
9
2
8
.
0
6
S
E
R
V
F
D
I
P
#
4
7
4
8
1
F
D
I
P
#
4
7
4
8
1
F
E
S
1
2
"
9
1
6
.
7
5
F
D
I
P
#
4
7
4
8
1
10
5
1
0
10
10
1
0
5
10
D
R
A
I
N
A
G
E
&
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
6.
4
%
G
A
R
A
G
E
F
B
W
O
P
O
R
C
H
P
R
O
P
O
S
E
D
H
O
U
S
E
(
9
3
2
.
1
7
)
(
9
2
9
.
0
)
(
9
3
0
.
6
)
(
9
1
9
.
5
)
(
9
1
9
.
5
)
(9
2
3
.
5
)
(9
2
3
.
5
)
V
A
C
A
N
T
L
O
T
V
A
C
A
N
T
L
O
T
C
O
N
S
E
R
V
A
T
I
O
N
P
O
S
T
C
O
N
S
E
R
V
A
T
I
O
N
P
O
S
T
N
3
8
°
0
4
'
5
1
"
E
12
5
.
9
9
6
6
.
2
9
S
6
1
°
0
2
'
2
4
"
E
1
3
1
.
6
5
N
4
3
°
4
7
'
2
9
"
E
N
6
5
°
2
7
'
1
6
"
W
4
8
.
1
6
Δ
=
1
1
°
5
1
'
1
5
"
R
=
1
5
5
.
0
0
3
2
.
0
7
5
.
0
0
1
7
.
5
0
2
4
.
0
0
1
2
.
1
7
1
8
.
0
0
3
5
.
6
6
3
4
.
0
0
1
0
.
8
3
2
.
0
0
6
.
5
0
1
2
.
0
0
1
8
.
7
5
2
.
0
0
1
1
.
7
5
A
C
C
O
N
C
.
6
'
x
8
'
9
2
8
.
5
9
2
8
.
6
9
2
9
.
4
9
3
0
.
1
9
3
0
.
2
9
2
7
.
1
9
1
9
.
2
9
2
2
.
5
9
2
2
.
2
9
2
2
.
3
9
2
1
.
9
(9
2
4
.
0
)
(9
2
9
.
8
)
(9
3
1
.
8
)
(9
3
1
.
2
)
9
2
8
.
5
9
2
9
.
6
9
1
9
.
3
9
1
8
.
3
9
2
4
.
6
9
2
3
.
7
9
2
9
.
0
9
2
9
.
0
9
2
9
.
2
9
2
8
.
1
P
O
N
D
1
P
N
W
L
:
9
1
6
.
8
0
1
0
0
Y
R
H
W
L
:
9
1
9
.
5
0
9
2
9
.
4
(9
3
1
.
2
)
(9
2
4
.
0
)
(9
2
2
.
0
)
E
X
P
O
S
E
E
X
T
R
A
F
O
U
N
D
A
T
I
O
N
A
S
N
E
E
D
E
D
2
0
F
T
D
E
C
K
S
E
T
B
A
C
K
L
I
N
E
31
.
9
37
.
6
2
4
.
0
2
0
.
0
M
A
X
I
M
U
M
A
L
L
O
W
E
D
D
R
I
V
E
W
A
Y
W
I
D
T
H
A
T
L
O
T
L
I
N
E
W
I
T
H
O
U
T
P
E
R
M
I
T
SI
D
E
W
A
L
K
O
S
2
9
.
6
3
H
U
B
=
9
2
8
.
7
2
(9
2
7
.
4
)
1
2
.
0
0
913.
9
9
1
3
.
9
9
1
3
.
9
1.
0
'
C
A
N
T
.
1.
0
'
C
A
N
T
.
1.
0
'
C
A
N
T
.
1
.
5
'
C
A
N
T
1
2
.
1
3
DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLE DENOTES EXISTING STORM MANHOLE DENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUT DENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0 DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALL DENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION (000.0)000.0DENOTES EXISTING TREELINE DENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCE LEGENDDENOTES EXISTING F.E.S.LOT AREA : 9,069 SQ. FT.HOUSE AREA : 1,676 SQ. FT.PORCH AREA : 101 SQ. FT.DRIVEWAY AREA : 805 SQ. FT.SIDEWALK AREA : 40 SQ. FT.PATIO AREA : 48 SQ. FT.TOTAL IMPERVIOUS AREA : 2,670 SQ. FT. (29.4%)
C
E
R
T
I
F
I
C
A
T
E
O
F
S
U
R
V
E
Y
Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION = TOP OF FOUNDATION ELEVATION (932.17)(932.50)(924.50)
1
.
N
o
s
p
e
c
i
f
i
c
s
o
i
l
s
i
n
v
e
s
t
i
g
a
t
i
o
n
h
a
s
b
e
e
n
p
e
r
f
o
r
m
e
d
o
n
t
h
i
s
l
o
t
b
y
t
h
e
s
u
r
v
e
y
o
r
.
T
h
e
s
u
i
t
a
b
i
l
i
t
y
o
f
t
h
e
s
o
i
l
s
t
o
s
u
p
p
o
r
t
t
h
e
s
p
e
c
i
f
i
c
h
o
u
s
e
i
s
n
o
t
t
h
e
r
e
s
p
o
n
s
i
b
i
l
i
t
y
o
f
t
h
e
s
u
r
v
e
y
o
r
.
2
.
N
o
t
i
t
l
e
i
n
f
o
r
m
a
t
i
o
n
w
a
s
p
r
o
v
i
d
e
d
f
o
r
t
h
i
s
s
u
r
v
e
y
.
T
h
i
s
s
u
r
v
e
y
d
o
e
s
n
o
t
p
u
r
p
o
r
t
t
o
s
h
o
w
a
l
l
e
a
s
e
m
e
n
t
s
o
f
r
e
c
o
r
d
.
3
.
S
e
e
a
r
c
h
i
t
e
c
t
u
r
a
l
p
l
a
n
s
f
o
r
f
i
n
a
l
b
u
i
l
d
i
n
g
d
i
m
e
n
s
i
o
n
s
.
AREAS:BENCHMARK: TNH AT LOTS 3 AND 4, BLOCK 1. ELEVATION = 1033.91 NOTES 1. 8'-4" POURED FOUNDATION 2. 924.40 MINIMUM LOW FLOOR 3. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 4. SILT FENCE AT GRADING LIMITS.
Z
o
n
i
n
g
=
R
M
-
1
F
Y
-
2
0
'
H
o
u
s
e
,
2
5
'
G
a
r
a
g
e
S
Y
-
7
'
I
n
t
e
r
i
o
r
,
2
0
'
C
o
r
n
e
r
R
Y
-
3
0
'
S
Y
B
u
f
f
e
r
-
5
0
'
R
Y
B
u
f
f
e
r
-
5
0
'
The curb box, drain tile clean
o
u
t
a
n
d
c
a
t
c
h
b
a
s
i
n
(if applicable) must be inspe
c
t
e
d
a
n
d
a
c
c
e
p
t
e
d
before As-built escrow monie
s
w
i
l
l
b
e
r
e
l
e
a
s
e
d
.
All structures must be flush
w
i
t
h
t
h
e
s
o
d
.
T
h
i
s
will be scheduled with the lan
d
s
c
a
p
e
i
n
s
p
e
c
t
i
o
n
.
EROSION
C
O
N
T
R
O
L
MUST BE I
N
S
T
A
L
L
E
D
BEFORE EX
C
A
V
A
T
I
O
N
9
2
1
.
4
9
2
2
.
0
*Maintain 6" b
e
t
w
e
e
n
s
i
d
i
n
g
&
s
o
d
*No structure
s
i
n
e
a
s
e
m
e
n
t
s
ENGINEERING REVIEW
E
D
Date: 09/25/2019 ajordan