Loading...
HomeMy WebLinkAboutLA175610 - 5697 Upper 197th St Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: MA I N F L O O R 93 0 . 7 UP P E R P L A T E 94 9 . 4 T. O . F O U N D A T I O N 92 9 T.O. FOUNDATION 929 MA I N P L A T E 93 9 . 8 MAIN PLATE 939.8 UP P E R F L O O R 94 1 . 3 M A I N F L O O R P L A T E H E I G H T 9 ' - 1 1 / 8 " U P P E R F L O O R P L A T E H E I G H T 8 ' - 1 1 / 8 " GARAGE PLATE HEIGHT 10' - 9 3/8" AL U M I N U M S O F F I T & F A S C I A T Y P . 6" S M A R T S I D E FR I E Z E B O A R D T Y P . VI N Y L B O A R D & B A T T E N T Y P . VINYL LAP SIDING W/ VINYL CORNERS ALL SIDES 4: 1 2 CU L T U R E D S T O N E W / CO N C R E T E C A P 3' - 6" 4" S M A R T S I D E T R I M @ W I N D O W S & D O O R S TY P . - FR O N T O N L Y AD D R E S S S T O N E 7: 1 2 12 8 T. O . G A R A G E FO U N D A T I O N 92 8 T.O. GARAGE FOUNDATION 928 7: 1 2 SE E C O L U M N DE T A I L S H E E T 7 6 4 ' - 0 " 6" SMARTSIDE STORYBOARD TYP. 12 8 RA I L I N G P E R C O D E 1/ 4 " = 1 ' - 0 " A- 2 0 1 1 FR O N T E L E V A T I O N T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:11 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-201 OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 SHEET INDEX SH E E T N A M E S H E E T N U M B E R EL E V A T I O N A - 2 0 1 EL E V A T I O N S A - 2 0 2 FO U N D A T I O N P L A N A - 4 0 1 LO W E R F L O O R A - 4 0 2 MA I N F L O O R A - 4 0 3 UP P E R F L O O R A - 4 0 4 RO O F / W I N D O W A - 5 0 1 DE T A I L S A - 5 0 2 Concept Approval ONLY Subject to Field Inspection In s p e c t o r Date2015MN Bldg Code 11/13/2019 sh u t c h i n s 8: 1 2 8: 1 2 12 7 24 " R E T U R N S TY P I C A L 7:12 12 7 AL U M I N U M S O F F I T & F A S C I A T Y P . VI N Y L S I D I N G & C O R N E R S 7: 1 2 12 8 12 7 12 7 8: 1 2 12 4 7: 1 2 4: 1 2 24 " R E T U R N S TY P I C A L 3 ' - 6 " 12 7 8: 1 2 T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:12 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-202OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 1/ 8 " = 1 ' - 0 " A- 2 0 2 1 RI G H T E L E V A T I O N 1/ 8 " = 1 ' - 0 " A- 2 0 2 2 RE A R E L E V A T I O N 1/ 8 " = 1 ' - 0 " A- 2 0 2 3 LE F T E L E V A T I O N Se c u r e d o o r c l o s e d u n t i l d e c k i s co n s t r u c t e d w i t h a s e p a r a t e p e r m i t . 48' - 0" 1 ' - 1 0 " 1 9 ' - 1 0 " 20 ' - 2 " 11 ' - 0 " 18 ' - 1 0 " 31 ' - 2 " 50 ' - 0 " 2 8 ' - 2 " 1 9 ' - 1 0 " 1' - 8 1 / 2 " 8' - 3 " M . O . 1' - 0 1 / 2 " 1' - 1 1 1 / 2 " 16 ' - 3 " M . O . 1' - 1 1 1 / 2 " 2' - 0" 20' - 6" 1 4 ' - 0 " 5 ' - 1 0 " 3'-6" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L W / 2" x 8 " I N T E R I O R L E D G E O N 16 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 8' -4" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 8'-4" ( H ) x 1 0 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L W / 4" x 2 0 " E X T E R I O R L E D G E O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 50 ' - 0 " 10 ' - 0 " 40 ' - 0 " :W A L K O U T W A L L : 2x 6 S T U D S @ 1 6 " O . C . O N 3'-6" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L W/ 2 " x 4 " I N T . L E D G E O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 19 ' - 8 " 20 ' - 4 " *A L L D I M E N S I O N S A R E T O OU T S I D E O F C O N C R E T E S T E P F O O T I N G & F O U N D A T I O N W A L L P E R G R A D E , V E R I F Y O N S I T E S T E P F O O T I N G & F O U N D A T I O N W A L L P E R G R A D E , V E R I F Y O N S I T E 4 8 ' - 0 " 7' - 0 " 8' - 0 " 4' - 0 3 / 4 " 3' - 1 1 1 / 4 " 3' - 1 0 3 / 4 " 13 ' - 1 1 / 4 " 8' -4" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . :L O O K O U T W A L L : 2x 6 S T U D S @ 1 6 " O . C . O N 3' -6" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 20 " x 8 " C O N C R E T E F T G . RE B A R P E R C O D E :L O O K O U T W A L L : 2x 6 S T U D S @ 1 6 " O . C . O N 3' -6" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 20 " x 8 " C O N C R E T E F T G . RE B A R P E R C O D E 25' - 6" 22' - 6" 40 ' - 0 " 8'-4" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 7' -4" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L O N 16 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 0 ' - 4 " 2 6 ' - 4 " 1 6 ' - 6 " 1 1 ' - 8 " 1 4 ' - 8 " 0 ' - 8 1 / 2 " 6 ' - 1 1 1 / 4 " 4 ' - 0 1 / 4 " 2x 6 S T U D S @ 1 6 " O . C . O N HA L F -HI G H 6 " B L O C K O N 16 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 42 " x 4 2 " x 1 2 " C O N C R E T E F T G . W/ ( 4 ) # 5 R E B A R E A C H W A Y TO O F G A R A G E F O U N D A T I O N T O DR O P 1 2 " F R O M T H E T O P O F HO U S E F O U N D A T I O N T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:13 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-401 OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 1/ 4 " = 1 ' - 0 " A- 4 0 1 1 FO U N D A T I O N P L A N UP 1 6 R UN E X C A V A T E D FU R N A C E SU M P W. H . F. D . 4' V A N I T Y FA M I L Y R O O M CA R P E T . BE D R O O M # 5 CA R P E T . BA T H VI N Y L . 25' - 6" 22' - 6" 1 ' - 1 0 " 1 9 ' - 1 0 " 20 ' - 2 " 11 ' - 0 " 18 ' - 1 0 " 31 ' - 2 " 2 8 ' - 2 " 1 9 ' - 1 0 " 1 5 ' - 1 0 " 5 ' - 1 0 " 4 ' - 8 " CO D E T . SM O K E DE T . 1 8 " F L O O R T R U S S E S P E R M F G . S P A C I N G 19 ' - 3 1 / 2 " 3' - 8 1 / 2 " 3' - 8 1 / 2 " 13 ' - 3 1 / 2 " 2' - 0" 20' - 6" 2/ 4 x 6 / 8 48 " F . G . S H W R CL O S E T CA R P E T . 2/ 6 x 6 / 8 2/ 6 x 6 / 8 1 8 " F L O O R T R U S S E S P E R M F G . S P A C I N G 1 4 ' - 0 " 5 ' - 1 0 " 1 1 ' - 8 " 1 6 ' - 6 " UN E X C A V A T E D 50 ' - 0 " 10 ' - 0 " 40 ' - 0 " R & S H . 2x 6 7' - 7 " 1' - 1 1 " 3' - 8 " 26 ' - 1 0 " 6' - 9 " 11 ' - 0 " 12 ' - 9 " 9' - 6 " 3 - 9 1 / 2 " L V L W/ 2 T R I M M E R S SM O K E DE T . *3 -1/ 2 " C O N C . F L O O R *M E C H A N I C A L S M A Y V A R Y 19 ' - 8 " 20 ' - 4 " 4' - 0 " B . W . P . 4' - 0 " B . W . P . 6/ 0 x 6 / 8 SL I D E R 4' - 0 " B . W . P . *A L L D I M E N S I O N S A R E T O OU T S I D E O F C O N C R E T E / S H E A T H I N G S T E P F O O T I N G & F O U N D A T I O N W A L L P E R G R A D E , V E R I F Y O N S I T E S T E P F O O T I N G & F O U N D A T I O N W A L L P E R G R A D E , V E R I F Y O N S I T E 2 -9 1 / 2 " L S L W/ 2 T R I M M E R S 2 -2x 1 0 2 -2x 1 0 2 -2x 1 0 2 -9 1 / 2 " L S L @ 6 5 " 24 " C A N T I L E V E R AB O V E 48' - 0" 4 8 ' - 0 " 50 ' - 0 " 40 ' - 0 " 4 ' - 3 1 / 4 " 1 1 ' - 3 3 / 4 " 1 0 ' - 9 " 0 ' - 4 " 2 -2x 1 0 W / 2 T R I M M E R S 2 6 ' - 4 " 1 4 ' - 8 " 1 1 ' - 8 " 2x 6 S T U D S @ 1 6 " O . C . O N HA L F -HI G H 6 " B L O C K O N 16 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . 1 7 4' - 3 1 / 2 " 7' - 1 1 " 7' - 1 " 1 ' - 0 " 2 ' - 6 " 2/ 8 x 6 / 8 ME C H A N I C A L / ST O R A G E UN F I N I S H E D . 2/ 4 x 6 / 8 AI R E X . 3 - 9 1 / 2 " L S L W/ 2 T R I M M E R S 2" F O A M I N S U L A T I O N BE T W E E N W A L L & S L A B 15 ' -6" O F BR A C E D W A L L RE Q U I R E D 15 ' -6" O F BR A C E D W A L L RE Q U I R E D W. S . 3 -11 7 / 8 " L S L FL U S H 4 -2x 6 4 -2x 6 FU T U R E B A R A R E A TO O F G A R A G E F O U N D A T I O N T O DR O P 1 2 " F R O M T H E T O P O F HO U S E F O U N D A T I O N F L O O R G I R D E R 1/ 4 " = 1 ' - 0 " A- 4 0 2 1 LO W E R F L O O R P L A N T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:14 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-402OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 CS -WS P M E T H O D B R A C E D W A L L P A N E L S - 8d N A I L S 6 " O N E D G E S & 1 2 " I N F I E L D , ST A C K B E T W E E N L E V E L S W H E N P O S S I B L E . US E ( 3 ) 1 6 d N A I L S N E X T T O E A C H ST U D T O S E C U R E W A L L D O W N T O D E C K AT B R A C E D W A L L P A N E L S . EX P O S U R E C A T E G O R Y B AS S U M E D BR A C E D W A L L N O T E S 2 UP 1 7 R DN 1 6 R DN 5 R DN 5 R 48' - 0" 2 8 ' - 0 " 2 0 ' - 0 " 50 ' - 0 " 3/ 0 x 6 / 8 W / 12 " D . S . SL ' S KI T C H E N WO O D . DI N I N G RO O M WO O D . GR E A T R O O M CA R P E T . FO Y E R WO O D . OF F I C E CA R P E T . MU D RO O M VI N Y L .DW 30 " R A N G E GA R A G E PO R C H CO N C R E T E . 12 " TR A N S O M / 6/ 0 x 6 / 8 SL I D E R 5 ' - 1 1 " 5 ' - 0 " 1 7 ' - 1 " 6 ' - 0 " 1 4 ' - 0 " 18 ' - 1 0 " 31 ' - 2 " 20 ' - 2 " 11 ' - 0 " 9' - 6 " 12 ' - 9 " 11 ' - 0 " 6' - 9 " 2 ' - 0 " 6 ' - 0 " 1 4 ' - 0 " 50 ' - 0 " 2' - 1 " 16 ' - 0 " 2' - 1 " 1' - 2 " 8' - 0 " 1' - 1 0 " 0 ' - 1 0 " 5 ' - 2 " 1' - 0 " 11 ' - 0 " 7' - 4 " SM O K E DE T . 4" C O N C R E T E S L A B , S L O P E TO W A R D S D O O R S 5/ 8 " T Y P E X G Y P . B D . A L L C O M M O N WA L L S & C E I L I N G GA R A G E P L A T E H E I G H T T O MA T C H M A I N F L O O R P L A T E 16 ' x 8 ' O . H . GA R A G E DO O R 8' x 8 ' O . H . GA R A G E DO O R 2 -11 7 / 8 " L S L 4' - 2 " 4' - 0 " 12 " C A N T . AB O V E 3' - 1 0 " 9' - 0 " 6' - 6 " SE E C O L U M N DE T A I L S H E E T 7 4 ' - 4 " 5 ' - 1 0 " 0 ' - 1 0 " 1 5 ' - 0 " 1 8 " F L O O R T R U S S E S P E R M F G . S P A C I N G 1 8 " F L O O R T R U S S E S P E R M F G . S P A C I N G MF G . R O O F T R U S S E S @ 2 4 " O . C . M F G . R O O F T R U S S E S @ 2 4 " O . C . 3 -2x 1 0 W / 2 T R I M M E R S 2 -9 1 / 2 " L S L W / 3 T R I M M E R S 2 -2x 1 0 D R O P P R D TY P . 0' - 4 1 / 2 " CL O S E T VI N Y L . 25' - 6" 22' - 6" 2/ 8 x 6 / 8 FI R E R A T E D 2/ 4 x 6 / 8 2' - 0" 20' - 6" 2 -2x 1 2 10 ' - 0 " 40 ' - 0 " S N A C K B A R 19 ' - 4 " 20 ' - 8 " PO R T A L F R A M E W / H O L D D O W N 3' - 0 " B . W . P . 4' - 0 " B . W . P . 3 ' - 0 " B . W . P . 4 ' - 0 " B . W . P . 3' - 0" B.W.P. 3' - 0" B.W.P. 3 ' - 0 " B . W . P . 3 ' - 0 " B . W . P . SI N K FI R E P L A C E S E T O N F L O O R - TI L E S U R R O U N D PO W D E R VI N Y L . 36 " R E F 2/ 0 x 6 / 8 PA N T R Y WO O D . 2/ 4 x 6 / 8 PE D . S I N K GA S F . P . 3/ 0 x 6 / 8 OP G . 2 -2X 1 0 2 -2X 1 0 C O N T . W / 2 T R I M M E R S 2 - 2 X 1 0 2 -11 7 / 8 " LS L F L U S H W / 3 T R I M M E R S 2 -2X 1 0 W / 2 T R I M M E R S PO R T A L F R A M E W / H O L D D O W N 2 -2X 1 0 2 - 2 X 1 0 2 - 2 X 1 0 3' - 0 " B . W . P . 3' - 0 " B . W . P . 3' - 0 " B . W . P . 4 ' - 0 " B . W . P . 3' - 0 " B . W . P . 3' - 0 " B . W . P . 4 ' - 0 " B . W . P . 2 -2X 1 0 4 8 ' - 0 " 7 ' - 5 " 1 8 ' - 7 " 3 ' - 2 3 / 4 " 5 ' - 6 " 3 ' - 2 " 2' - 0 " 3 ' - 9 " 2 ' - 0 " 3 ' - 4 " 4 ' - 2 1 / 4 " 1 2 ' - 8 3 / 4 " 12 ' - 2 " 19 ' - 8 " 3' - 8 " 4' - 6 " 1 1 ' - 6 " 1 6 ' - 6 " 19 ' - 3 1 / 2 " 3' - 8 1 / 2 " 3' - 8 1 / 2 " 13 ' - 3 1 / 2 " 2 -2X 1 0 2 -9 1 / 2 " L S L FL U S H 24 " C A N T I L E V E R A B O V E 2 6 ' - 0 " 9' - 7 1 / 2 " 11 ' - 0 1 / 2 " 40 ' - 0 " KN E E W A L L W / 14 " ( H ) S P I N D L E S 2 -2X 1 0 2 -11 7 / 8 " LS L F L U S H 2 -11 7 / 8 " LS L F L U S H W/ 3 T R I M M E R S 5/ 0 x 6 / 8 OP G . 9" H E A T D U C T 2 ' - 0 " 2' - 0 " 4 ' - 0 " 3 ' - 9 " 6 ' - 6 " 2 ' - 1 0 " 3 ' - 1 " 2 ' - 1 0 " E Q E Q 11 11 11 10 9 9 2 4 AT T I C AC C E S S 3' - 0 " B . W . P . 5 ' - 0 " B . W . P . B . W . P . 4 ' - 0 " 3' - 0 " B . W . P . W/ G A R A G E O P E N E R 6 6 2 -2X 1 0 2 -2X 1 0 8 ' - 0 " H . H . 8 ' - 0 " H . H . R & S H . TO O F G A R A G E F O U N D A T I O N T O DR O P 1 2 " F R O M T H E T O P O F HO U S E F O U N D A T I O N 0 ' - 6 " RA I L I N G PE R C O D E 3 ' - 6 " 3' - 6 " 3' - 4 " RA I L I N G PE R C O D E HH U S 4 8 HH U S 4 8 1 1 ' - 4 " 1 4 ' - 8 " 1/ 4 " = 1 ' - 0 " A- 4 0 3 1 MA I N F L O O R P L A N T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:14 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-403OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 CS -WS P M E T H O D B R A C E D W A L L P A N E L S - 8d N A I L S 6 " O N E D G E S & 1 2 " I N F I E L D , ST A C K B E T W E E N L E V E L S W H E N P O S S I B L E . US E ( 3 ) 1 6 d N A I L S N E X T T O E A C H ST U D T O S E C U R E W A L L D O W N T O D E C K AT B R A C E D W A L L P A N E L S . EX P O S U R E C A T E G O R Y B AS S U M E D BR A C E D W A L L N O T E S DN 1 7 R BE D R O O M # 4 CA R P E T . LA U N D R Y VI N Y L . BE D R O O M # 3 CA R P E T . OW N E R ' S SU I T E CA R P E T VA U L T E D HA L L CA R P E T . 1/ 2 W A L L W / WO O D C A P SM O K E DE T . SM O K E DE T . EN SU I T E VI N Y L . 6' V A N I T Y CL O S E T CA R P E T . R & S H . KN E E W A L L W / 14 " ( H ) S P I N D L E S 2/ 6 x 6 / 8 SM O K E DE T . 2/ 8 x 6 / 8 2/ 6 x 6 / 8 R & S H . 2/ 6 x 6 / 8 BE D R O O M # 2 CA R P E T . GI R D E R T R U S S CO D E T . SM O K E DE T . M F G . R O O F T R U S S E S @ 2 4 " O . C . MF G . R O O F T R U S S E S @ 2 4 " O . C . AT T I C AC C E S S 2' L I N E N 2/ 6 x 6 / 8 2/ 6 x 6 / 8 PK T 4: 1 2 4: 1 2 GI R D E R TR U S S 13 ' - 0 " 27 ' - 0 " 3 ' - 0 " 2 8 ' - 0 " 2 9 ' - 0 " 2 ' - 0 " 26 ' - 6 " 13 ' - 6 " R & S H . 2/ 4 x 6 / 8 2/ 4 x 6 / 8 6' - 4 " 14 ' - 6 " 5' - 8 " 6' - 9 " 6' - 9 " 2 / 6 x 6 / 8 CL O S E T CA R P E T . BA T H VI N Y L . 2x 6 3' V A N I T Y R & S H . 2/ 4 x 6 / 8 2/ 4 x 6 / 8 6' - 6 " 6' - 6 " 2' - 6 " 7' - 6 " 17 ' - 0 " V A U L T L I N E M F G . R O O F T R U S S E S @ 2 4 " O . C . MF G . R O O F T R U S S E S @ 2 4 " O . C . 2 -2x 1 0 W / 2 T R I M M E R S 2 -2x 1 0 2 -2x 1 0 2 -2x 1 0 2 -2x 1 0 2' - 3 " B . W . P . 2' - 3 " B . W . P . 2' - 3 " B . W . P . 2' - 3 " B . W . P . 2 ' - 3 " B . W . P . 2 ' - 3 " B . W . P . 2 ' - 3 " B . W . P . 2' - 3 " B . W . P . 3' - 0 " B . W . P . 2' - 3 " B . W . P . 2 ' - 3 " B . W . P . 2 ' - 3 " B . W . P . 2 ' - 3 " B . W . P . 40 ' - 0 " 6 ' - 1 " 2 1 ' - 1 1 " 3 1 ' - 0 " 3 1 ' - 0 " 40 ' - 0 " 8 ' - 0 " 5 ' - 5 " 4 ' - 3 " 1 ' - 8 " 4 ' - 8 " 5 ' - 0 " 8 ' - 6 " 5 ' - 0 " 1 4 ' - 6 " 9' - 2 " 3' - 6 " 2' - 6 " 11 ' - 8 1 / 4 " 3' - 4 " 3' - 1 " 6' - 8 3 / 4 " 19 ' - 3 1 / 2 " 3' - 8 1 / 2 " 3' - 8 1 / 2 " 13 ' - 3 1 / 2 " 4 ' - 4 " 5 ' - 0 " 0 ' - 1 0 " 1 5 ' - 1 0 " @ 6 5 " @ 6 5 " @ 6 5 " @ 6 5 " 2 -2x 1 0 2 -2x 1 0 W / 2 T R I M M E R S 5 4 4 31 1 8 5' T U B / S H W R SM O K E DE T . DB L F R A M E FO R P L U M B I N G WA L L 3' - 0 " B . W . P . 1 ' - 4 7 / 8 " 1 ' - 3 1 / 8 " 2 ' - 6 1 / 4 " 48 " F . G . SH O W E R W/ T I L E W A L L S & B Y P A S S D O O R 3' x 5 ' T U B W / TI L E D E C K 3' - 5 3 / 4 " 6' - 7 3 / 4 " ST A C K W / D T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:15 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-404OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 1/ 4 " = 1 ' - 0 " A- 4 0 4 1 UP P E R F L O O R P L A N CS -WS P M E T H O D B R A C E D W A L L P A N E L S - 8d N A I L S 6 " O N E D G E S & 1 2 " I N F I E L D , ST A C K B E T W E E N L E V E L S W H E N P O S S I B L E . US E ( 3 ) 1 6 d N A I L S N E X T T O E A C H ST U D T O S E C U R E W A L L D O W N T O D E C K AT B R A C E D W A L L P A N E L S . EX P O S U R E C A T E G O R Y B AS S U M E D BR A C E D W A L L N O T E S 4: 1 2 ST A N D A R D E N E R G Y H E E L S @ 4: 1 2 & 7 : 1 2 P I T C H T Y P . 8: 1 2 8: 1 2 8: 1 2 8: 1 2 7: 1 2 7: 1 2 4: 1 2 7: 1 2 7: 1 2 HE E L S @ 8 : 1 2 P I T C H T O M A T C H 18 " O V E R H A N G S & 1 2 " R A K E S T Y P . 6 R O O F V E N T S @ H O U S E 4 R O O F V E N T S @ G A R A G E 7: 1 2 WATCH DOG WATER PROOF COATINGFROM FOOTING TO SILL SEALER 6 M I L P O L Y V . B . , O V E R L A P ED G E S M I N . 1 2 " & T A P E . SE A L A L L O P E N I N G S 4" M I N . L A Y E R 3/ 4 " R I V E R R O C K 3 1 / 2 " C O N C R E T E S L A B ANCHOR BOLT PER CODE TRT'D 2x8 SILL PLATE W/ CLOSED CELL ROLL SILL SEALER GRADE GRANULAR FILL 4" DRAIN TILE W/ SILT SOCK 1" F O A M B O A R D ( R -5) I N S U L A T I O N W/ A C O U S T I C A L S E A L A N T @ T O P & B O T T O M E D G E S , B E T W E E N I N S U L . & S L A B & A T A L L V E R T I C A L E D G E S PO L Y U R E T H A N E C A U L K OR E L A S T O M E R I C SE A L A N T @ A L L J O I N T S MIN. 0' - 6" VE R I F Y F L O O R S Y S T E M WI T H F L O O R P L A N S 3/ 4 " T & G SU B F L O O R L O W E R P L A T E H E I G H T 8 ' - 2 " M A I N F L O O R P L A T E H E I G H T 9 ' - 1 1 / 8 " 6 M I L . V . B . 1/ 2 " G Y P . B D . VE R I F Y F L O O R S Y S T E M WI T H F L O O R P L A N S U P P E R F L O O R P L A T E H E I G H T 8 ' - 1 1 / 8 " 6 M I L . V . B . 1/ 2 " G Y P . B D . 3/ 4 " T & G SU B F L O O R 6 M I L . V . B . 2x6 STUDS @ 16" O.C. W/ R -21 F.G. INSULATION 2x6 STUDS @ 16" O.C. W/ R -21 F.G. INSULATION 8'-4"(H) x 8"(W) POURED CONCRETE FOUND. WALL ON 20" x 8" CONCRETE FTG'S. REBAR PER CODE. 1/2" OSB SHEATHING TYVEK (OR EQUAL) ROLL HOUSE WRAP SIDING, VERIFY W/ ELEVATIONS 5/ 8 " G Y P . B D . 5/ 8 " G Y P . B D . VENTED ALUMINUM SOFFIT PANELS ICE & WATER GUARD FROM EAVE TO 2'-0" MIN. OVER STRUCTURE VENT CHUTES & WIND WASH @ EACH TRUSS SPACE ASPHALT SHINGLES W/ 15# ROLL FELT UNDER 1/2" OSB ROOF SHEATHING MF G . R O O F TR U S S E S @ 2 4 " O . C . AT T I C V E N T I N G AS P E R C O D E R -49 M I N . B L O W N AT T I C I N S U L A T I O N ALUMINUM FASCIA W/ 2x6 SUB FASCIA ALUMINUM DRIP EDGE RIM JOIST RIM JOIST R -20 M I N . S P R A Y FO A M I N S U L A T I O N , CO V E R F O U N D A T I O N W A L L GMX THERMAL DRAINAGE BOARD (R -10) INSULATION DRYVIT INSULATION PROTECTION FROM SIDING TO 6" BELOW GRADE 5000 PSI CONCRETE @ ALL FOOTINGS *O U T S I D E O F F O U N D A T I O N TO A L I G N W I T H O U T S I D E O F SHEATING R -20 M I N . S P R A Y FO A M I N S U L A T I O N 1' - 5 " 0' - 9 1 / 2 " 2x 4 @ B O T T O M 1x 3 T Y P . 2x 2 2x 4 @ T O P SM O O T H L P SM A R T S I D E T Y P . SO F F I T 1 ' - 9 1 / 2 " 1' - 0 " FR O N T SI D E TO P V I E W 1' - 5 " 0 ' - 9 1 / 2 " FR A M I N G 4x 4 P O S T T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:16 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-501 OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 1/ 8 " = 1 ' - 0 " A- 5 0 1 1 RO O F P L A N 3" M I N . A B S O R P V C G A S T I G H T PI P E F R O M S U B S L A B T O MI N . 1 2 " A B O V E R O O F , M U S T BE R U N T H R U C O N D I T I O N E D S P A C E . PI P E C A N B E C O N N E C T E D T O SU M P S Y S T E M O R H A V E "T " F I T T I N G ( M I N . 1 0 ' -0" E A . W A Y ) IN G R A V E L U N D E R S L A B . EN D O F P I P E M U S T B E M I N . 1 0 ' -0" AW A Y F R O M A N Y W I N D O W O R OT H E R O P E N I N G T H A T I S L E S S TH A N 2 ' -0" B E L O W E N D O F P I P E . EN D O F P I P E M U S T A L S O B E MI N . 1 0 ' -0" A W A Y F R O M A N Y WI N D O W O R O T H E R O P E N I N G I N AD J O I N I N G O R A D J A C E N T BU I L D I N G S . SU F F I C I E N T S P A C E M U S T B E LE F T A R O U N D P I P E I N A T T I C S P A C E TO A D D F A N . S P A C E M U S T B E MI N . ∅24 " C E N T E R E D O N A X I S O F PI P E W / M I N . 3 ' -0" V E R T I C A L S P A C E . A S I N G L E P I P E C A N B E U S E D I F A L L SO I L G A S E S I N D W E L L I N G C A N FL O W F R E E L Y B E T W E E N A L L L E V E L S OF F O U N D A T I O N . T H I S I N C L U D E S IN T E R I O R F O O T I N G S & O T H E R BA R R I E R S I F A I R F L O W H A S BE E N E S T A B L I S H E D . LA B E L T H E V E N T P I P E A T L E A S T ON C E P E R F L O O R A N D I N AC C E S S I B L E A T T I C S W I T H "R A D O N R E D U C T I O N S Y S T E M " . ON E E L E C T R I C A L R E C E P T A C L E I S RE Q U I R E D I N T H E A T T I C N E A R TH E V E N T P I P E F O R O P T . F A N . :PA S S I V E R A D O N S Y S T E M : 3/ 8 " = 1 ' - 0 " A- 5 0 1 2 TY P . W A L L S E C T I O N WI N D O W S C H E D U L E TY P E M A R K M A N U F A C T U R E R M O D E L C O U N T U N I T R O U G H W I D T H R O U G H H E I G H T H E A D H E I G H T 1 W I N D S O R N E X T D I M E N S I O N 3 6 0 4 8 S L 5 ' - 0 " 4 ' - 0 " 6 ' - 1 0 " 2 W I N D S O R N E X T D I M E N S I O N 1 7 2 6 0 S L 6 ' - 0 " 5 ' - 0 " 6 ' - 1 0 " 3 W I N D S O R N E X T D I M E N S I O N 1 6 0 6 0 S L 5 ' - 0 " 5 ' - 0 " 6 ' - 1 0 " 4 W I N D S O R N E X T D I M E N S I O N 3 2 4 2 4 A W N 2 ' - 0 " 2 ' - 0 " 6 ' - 1 0" 5 W I N D S O R N E X T D I M E N S I O N 1 2 4 2 4 - 2 F I X E D 4 ' - 0 " 2 ' - 0 " 6 ' - 1 0 " 6 W I N D S O R N E X T D I M E N S I O N 3 2 4 2 4 A W N F I X E D 2 ' - 0 " 2 ' - 0 " 7 W I N D S O R N E X T D I M E N S I O N 1 2 4 - 4 8 - 2 4 4 8 S L 8 ' - 0 " 4 ' - 0 " 6 ' - 1 0 " 8 W I N D S O R N E X T D I M E N S I O N 1 2 4 - 4 8 - 2 4 6 0 S L 8 ' - 0 " 5 ' - 0 " 6 ' - 1 0 " 9 W I N D S O R N E X T D I M E N S I O N 2 3 6 1 8 P I C 3 ' - 0 " 1 ' - 6 " 8 ' - 0 " 10 W I N D S O R N E X T D I M E N S I O N 1 4 2 4 2 S L 3 ' - 6 " 3 ' - 6 " 6 ' - 1 0" 11 W I N D S O R N E X T D I M E N S I O N 3 P 4 2 6 0 / A R 2 4 T 4 ' - 0 " 7 ' - 0 " 8 ' - 0 " 1/ 2 " = 1 ' - 0 " A- 5 0 1 3 TY P . C O L U M N 6 M I L P O L Y V . B . , O V E R L A P ED G E S M I N . 1 2 " & T A P E . SE A L A L L O P E N I N G S 4" M I N . L A Y E R 3/ 4 " R I V E R R O C K 3 1 / 2 " C O N C R E T E S L A B AN C H O R B O L T PE R C O D E TY P I C A L 2 x 6 EX T E R I O R W A L L TR T ' D 2 x 6 S I L L P L A T E W/ R O L L S I L L S E A L E R GR A D E GR A N U L A R F I L L :W A L K O U T W A L L : 2x 6 S T U D S @ 1 6 " O . C . O N 3'-6" ( H ) x 8 " ( W ) P O U R E D CO N C R E T E F O U N D . W A L L W/ 2 " x 4 " I N T . L E D G E O N 20 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . PO L Y U R E T H A N E C A U L K OR E L A S T O M E R I C SE A L A N T @ A L L J O I N T S M I N . 0 ' - 6 " 50 0 0 P S I C O N C R E T E @ A L L F O O T I N G S 2" F O A M B O A R D (R -10 ) I N S U L A T I O N 4" D R A I N T I L E W/ S I L T S O C K WA T E R P R O O F C O A T I N G FR O M F O O T I N G T O SI L L S E A L E R AN C H O R B O L T PE R C O D E TR T ' D 2 x 6 S I L L P L A T E W/ R O L L S I L L S E A L E R 1" F O A M B O A R D ( R -5) I N S U L A T I O N W/ A C O U S T I C A L S E A L A N T @ T O P & B O T T O M E D G E S , B E T W E E N I N S U L . & S L A B & A T A L L V E R T I C A L E D G E S VE R I F Y F L O O R S Y S T E M WI T H F L O O R P L A N S 3/ 4 " T & G SU B F L O O R 6 M I L . V . B . 1/ 2 " G Y P . B D . 2x 6 S T U D S @ 1 6 " O . C . W/ R -20 F . G . I N S U L A T I O N 1/ 2 " O S B SH E A T H I N G RI M J O I S T R -20 M I N . S P R A Y FO A M I N S U L A T I O N GM X T H E R M A L D R A I N A G E B O A R D (R -10 ) I N S U L A T I O N 5/ 8 " G Y P . B D . , T A P E & M U D A L L S E A M S SL O P E D C O N C R E T E ST O O P , F L A S H A S R E Q ' D AT H O U S E W A L L PO U R E D FN D . W A L L WA T C H D O G W A T E R P R O O F CO A T I N G F R O M F O O T I N G T O SI L L S E A L E R SI D I N G , V E R I F Y W/ E L E V A T I O N S TY V E K ( O R E Q U A L ) RO L L H O U S E W R A P 0' - 2 " FR O M S H E A T H I N G T O OU T S I D E O F F O U N D A T I O N AN C H O R B O L T PE R C O D E TR T ' D 2 x 6 S I L L P L A T E W/ R O L L S I L L S E A L E R 1" F O A M B O A R D ( R -5) I N S U L A T I O N W/ A C O U S T I C A L S E A L A N T @ T O P & B O T T O M E D G E S , B E T W E E N I N S U L . & S L A B & A T A L L V E R T I C A L E D G E S 3/ 4 " T & G SU B F L O O R 6 M I L . V . B . 1/ 2 " G Y P . B D . 2x 6 S T U D S @ 1 6 " O . C . W/ R -20 F . G . I N S U L A T I O N 5/ 8 " T Y P E ' X ' G Y P B O A R D , TA P E & M U D A L L S E A M S RI M J O I S T R -20 M I N . S P R A Y FO A M I N S U L A T I O N GM X T H E R M A L D R A I N A G E B O A R D (R -10 ) I N S U L A T I O N 5/ 8 " G Y P . B D . , T A P E & M U D A L L S E A M S SL O P E D C O N C R E T E SL A B , F L A S H A S R E Q ' D AT H O U S E W A L L 0' - 4 " PO U R E D FN D . W A L L WA T C H D O G W A T E R P R O O F CO A T I N G F R O M F O O T I N G T O SI L L S E A L E R VE R I F Y F L O O R S Y S T E M WI T H F L O O R P L A N S 1 ' - 8 " FASTEN TOP PLATE TO HEADER W/ (2) ROWS OF 16d SINKER NAILS @ 3" O.C. TYP. MIN. 3/8" WOOD STRUCTURAL PANEL SHEATHING SECTION TE N S I O N S T R A P P E R TA B L E R 6 0 2 . 1 0 . 6 . 4 (O N O P P O S I T E S I D E OF S H E A T H I N G ) IF N E E D E D , P A N E L SP L I C E E D G E S S H A L L OC C U R O V E R A N D B E NA I L E D T O C O M M O N BL O C K I N G W I T H I N MI D D L E 2 4 " O F W A L L MI D -HE I G H T . O N E RO W O F 3 " O . C . NA I L I N G I S R E Q U I R E D IN E A C H P A N E L E D G E . TY P I C A L P O R T A L FR A M E C O N S T R U C T I O N . MI N . D O U B L E 2 x 4 P O S T (K I N G A N D J A C K S T U D ) . NU M B E R O F J A C K S T U D S PE R T A B L E S R 5 0 2 . 5 ( 1 ) & ( 2 ) . MI N . 1 0 0 0 L B H O L D -DO W N DE V I C E ( E M B E D D E D I N T O CO N C R E T E & N A I L E D IN T O F R A M I N G ) FR O N T E L E V A T I O N MI N . F O O T I N G S I Z E U N D E R O P E N I N G I S 12 " X 1 2 " . A T U R N E D D O W N S L A B S H A L L BE P E R M I T T E D A T D O O R O P E N I N G S . MI N . ( 1 ) 5 / 8 " D I A . A N C H O R B O L D IN S T A L L E D P E R R 4 0 3 . 1 . 6 W / 2" X 2 " X 3 / 1 6 " P L A T E W A S H E R . MI N . R E I N F O R C I N G O F F O U N D A T I O N , ON E # 4 B A R T O P & B O T T O M O F FO O T I N G . L A P B A R S 1 5 " M I N I M U M . MI N . ( 2 ) 4 2 0 0 L B S T R A P -TY P E H O L D - DO W N S ( E M B E D D E D I N T O C O N C R E T E AN D N A I L E D I N T O F R A M I N G ) MI N . L E N G T H O F P A N E L PE R T A B L E R 6 0 2 . 1 0 . 5 MI N . D O U B L E 2 x 4 F R A M I N G C O V E R E D WI T H M I N . 3 / 8 " T H I C K W O O D S T R U C T U R A L PA N E L S H E A T H I N G W / 8 d C O M M O N O R GA L V A N I Z E D B O X N A I L S A T 3 " O . C . I N AL L F R A M I N G ( S T U D S , B L O C K I N G A N D S I L L S ) T Y P . HE A D E R T O J A C K S T U D S T R A P P E R TA B L E R 6 0 2 . 1 0 . 6 . 4 O N B O T H S I D E S O F OP E N I N G O P P O S I T E S I D E O F S H E A T H I N G FA S T E N S H E A T H I N G T O H E A D E R W I T H 8d C O M M O N O R G A L V A N I Z E D B O X NA I L S I N 3 " G R I D P A T T E R N A S S H O W N MI N . 3 " X 1 1 1 / 4 " N E T H E A D E R , ST E E L H E A D E R P R O H I B I T E D 9 ' - 1 1 1 / 4 " M A X . H E I G H T H E I G H T P O N Y W A L L 1 2 ' - 0 " M A X T O T A L W A L L H E I G H T EX T E N T O F H E A D E R W I T H S I N G L E P O R T A L FR A M E ( O N E B R A C E D W A L L P A N E L ) 2' - 0 " T O 1 8 ' - 0 " F I N I S H E D W I D T H O F OP E N I N G F O R S I N G L E O R D O U B L E P O R T A L 2x 6 S T U D S @ 1 6 " O . C . O N HA L F -HI G H 6 " B L O C K O N 16 " x 8 " C O N C R E T E F T G ' S . RE B A R P E R C O D E . TR T ' D S I L L P L A T E PO L Y U R E T H A N E C A U L K OR E L A S T O M E R I C SE A L A N T @ A L L J O I N T S SL E E V E E V E R Y 10 ' -0" M I N . 6 M I L P O L Y V . B . , O V E R L A P ED G E S M I N . 1 2 " & T A P E . SE A L A L L O P E N I N G S 4" M I N . L A Y E R 3/ 4 " R I V E R R O C K 3 1 / 2 " C O N C R E T E S L A B AN C H O R B O L T PE R C O D E 50 0 0 P S I C O N C R E T E @ A L L F O O T I N G S WATER PROOF COATING FROM FOOTING TO INSIDE OF WALL 6 M I L P O L Y V . B . , O V E R L A P ED G E S M I N . 1 2 " & T A P E . SE A L A L L O P E N I N G S 4" M I N . L A Y E R 3/ 4 " R I V E R R O C K 3 1 / 2 " C O N C R E T E S L A B ANCHOR BOLT PER CODE TYPICAL 2x6 EXTERIOR WALL TRT'D 2x6 SILL PLATE W/ ROLL SILL SEALER GRADE MIN. 0' - 6" GRANULAR FILL 4" DRAIN TILE W/ SILT SOCK :LOOKOUT WALL: 2x6 STUDS @ 16" O.C. ON 3'-6"(H) x 8"(W) POURED CONCRETE FOUND. WALL ON 20" x 8" CONCRETE FTG. REBAR PER CODE PO L Y U R E T H A N E C A U L K OR E L A S T O M E R I C SE A L A N T @ A L L J O I N T S 1" F O A M B O A R D ( R -5) I N S U L A T I O N W/ A C O U S T I C A L S E A L A N T @ T O P & B O T T O M E D G E S , B E T W E E N I N S U L . & S L A B & A T A L L V E R T I C A L E D G E S IN S U L A T I O N & S E A L A N T T O BE C O N T . O V E R W A L L 2" FOAMBOARD (R -10) INSULATION DRYVIT INSULATION PROTECTION FROM SIDING TO 6" BELOW GRADE 50 0 0 P S I C O N C R E T E @ A L L F O O T I N G S *O U T S I D E O F F O U N D A T I O N T O A L I G N W I T H OU T S I D E O F S H E A T H I N G T H E I D E A S , D E S I G N S , D R A W I N G S A N D S P E C I F I C A T I O N S R E P R E S E N T E D H E R E I N A R E A N D S H A L L R E M A I N T H E E X C L U S I V E C O P Y R I G H T P R O P E R T Y O F O N E T E N T E N H O M E S . N O P A R T T H E R E O F S H A L L B E U S E D , C O P I E D , O R D I S C L O S E D I N C O N N E C T I O N W I T H A N Y W O R K O R P R O J E C T O T H E R T H A N T H E S P E C I F I E D P R O J E C T F O R W H I C H T H E Y H A V E B E E N P R E P A R E D W I T H O U T T H E W R I T T E N C O N S E N T O F O N E T E N T E N H O M E S . T H E P L A N S F U R N I S H E D H E R E I N W E R E P R E P A R E D U P O N R E Q U E S T B Y D R A F T S P E R S O N S W H O A R E N O T R E G I S T E R E D A R C H I T E C T S O R E N G I N E E R S . O N E T E N T E N H O M E S A S S U M E S N O R E S P O N S I B I L I T Y F O R S T R U C T U R A L O R D I M E N S I O N A L E R R O R S O R O M I S S I O N S . T H E C O N T R A C T O R A N D / O R O W N E R M U S T V E R I F Y A N D C H E C K A L L N O T E S D E T A I L S , E L E V A T I O N S , S E C T I O N S A N D F L O O R P L A N S A N D N O T I F Y O N E T E N T E N H O M E S O F A N Y E R R O R S O R O M I S S I O N S P R I O R T O T H E S T A R T O F C O N S T R U C T I O N . N O W A R R A N T I E S A R E E X P R E S S E D O R I M P L I E D I N C L U D I N G C O M P L I A N C E O F T H I S P L A N W I T H A P P L I C A B L E B U I L D I N G C O D E R E Q U I R E M E N T S . T H E S E L E C T I O N A N D A P P L I C A T I O N O F C O R R E C T S T R U C T U R A L M A T E R I A L S I S T H E R E S P O N S I B I L I T Y O F T H E B U I L D E R , T H E O W N E R O R T H E U S E R O F T H E S E P L A N S . DATE SQUARE FEET PROJECT SHEET UPPER: MAIN: GARAGE: LOWER: RELEASED REV. 1 REV. 2 REV. 3 REV. 4 REV. 5 PLATE HEIGHTS UPPER: MAIN: POUR: P.O. BOX 391 5411 LAKERS LANE, SUITE 204 NISSWA, MN 56468 PH (612) 327-7582 NORTHHOUSE-RD.COM BRAINERD LAKES TWIN CITIES 3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337 PH (952)-953-4000 ONETENTENHOMES.COM UN S P E C I F I E D H E A D E R S T O B E 2 -2x 1 0 W / 2 T R I M M E R S 10 " M I N . S T A I R T R E A D D E P T H & 7 3 / 4 " M A X S T A I R R I S E R H E I G H T AL L A N G L E S A R E 4 5 D E G R E E S U N L E S S N O T E D O T H E R W I S E AL L E X T E R I O R D I M E N S I O N S A R E T O O U T S I D E O F S H E A T H I N G , CONCRETE OR FOUNDATION INSULATION TOTAL: 10/18/2019 12:35:17 PM THE BOWE & THIEL RESIDENCE L10, B3 - KNOB HILL 5697 UPPER 179th STREET LAKEVILLE, MN 55044 A-502OTT0669.26.19 CB 1106 1089 785 (668) 10.9.19 CB 10.15.19 CB 10.18.19 CB 9.5.19 CB 8'-1 1/8" 9'-1 1/8" 8'-4" PAYTON XL 2980 1/ 2 " = 1 ' - 0 " A- 5 0 2 1 TY P . W A L K O U T S E C T I O N 1/ 2 " = 1 ' - 0 " A- 5 0 2 2 TY P . H O U S E / S T O O P W A L L 1/ 2 " = 1 ' - 0 " A- 5 0 2 3 TY P . H O U S E / G A R A G E W A L L 3/ 8 " = 1 ' - 0 " A- 5 0 2 4 ME T H O D P F H - P O R T A L F R A M E W I T H H O L D - D O W N S 1/ 2 " = 1 ' - 0 " A- 5 0 2 5 BE A R I N G W A L L S E C T I O N 1/ 2 " = 1 ' - 0 " A- 5 0 2 6 TY P . L O O K O U T S E C T I O N 01: Upper Level Member Name Results Current Solution Comments Owner's Suite Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #2 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #3 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bed #4 WIC Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Stairway Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Owner's Bath Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 02: Main Level Member Name Results Current Solution Comments Kitchen Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Patio Door Passed 3 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Window Rear Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Office Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Drop Beam over Front Porch (H)Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Beam over Foyer (H)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Flush Beam over Foyer (V)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Foyer Entry Door Passed 2 Piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Flush Beam over Foyer/Dining Room (H)Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Beam over Pantry Passed 2 Piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 16' Garage Door Opening Passed 2 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 8' Garage Door Opening Passed 2 Piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 Bath Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Garage Mudroom Service Door Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Side Windows (2)Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Mudroom Opening Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 03: Lower Level Member Name Results Current Solution Comments Bath Door Passed 2 Piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Beam over Hallway/Mech Room Passed 2 Piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bedroom #5 Window Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Family Room Patio Door Passed 2 Piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Family Room Window Passed 3 Piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL WIC Door Passed 2 Piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bar FLR Beam Passed 3 Piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 5697 Upper 179th St W, Lakeville, MN.4te JOB SUMMARY REPORT Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 1 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None 2 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1156 @ 1 1/2"3825 (3.00")Passed (30%)--1.0 D + 1.0 S (All Spans) Shear (lbs)878 @ 1' 1/4"2872 Passed (31%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2314 @ 4' 3"3946 Passed (59%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.040 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.102 @ 4' 3"0.412 Passed (L/967)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Owner's Suite WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 7.0 1 - Uniform (PSF)0 to 8' 6"3'20.0 35.0 Snow - Main 2 - Uniform (PSF)0 to 8' 6"1'100.0 -Wall - Gable Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 2 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bedroom #2 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 3 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bedroom #3 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 4 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"345 591 936 None 2 - Trimmer - SPF 1.50"1.50"1.50"345 591 936 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)936 @ 0 1913 (1.50")Passed (49%)--1.0 D + 1.0 S (All Spans) Shear (lbs)191 @ 10 3/4"2872 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)527 @ 1' 1 1/2"3946 Passed (13%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.001 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Bed #4 WIC WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"15'20.0 35.0 Snow - Main Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 5 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None 2 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1768 @ 0 1913 (1.50")Passed (92%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1023 @ 10 3/4"2872 Passed (36%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1879 @ 2' 1 1/2"3946 Passed (48%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.022 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Stairway WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 7.0 1 - Uniform (PSF)0 to 4' 3"15'20.0 35.0 Snow - Main Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 6 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None 2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans) Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Upper Level, Owner's Bath WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main 2 - Uniform (PSF)0 to 2' 3"1'100.0 -Wall - Gable Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 7 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None 2 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1143 @ 0 1913 (1.50")Passed (60%)--1.0 D + 1.0 L (All Spans) Shear (lbs)597 @ 10 3/4"2498 Passed (24%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1071 @ 1' 10 1/2"3431 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 10 1/2"0.125 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.010 @ 1' 10 1/2"0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Kitchen WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 9"N/A 7.0 1 - Uniform (PSF)0 to 3' 9"9' 6"15.0 40.0 Floor - Upper Level 2 - Uniform (PLF)0 to 3' 9"N/A 80.0 -Wall - Upper Level Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 8 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1022 1040 581 2643 None 2 - Trimmer - SPF 3.00"3.00"2.09"1791 1040 1913 4744 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4006 @ 6' 4 1/2"5738 (3.00")Passed (70%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)2837 @ 5' 5 3/4"4308 Passed (66%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)5231 @ 4' 6"5919 Passed (88%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.045 @ 3' 4 15/16"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.081 @ 3' 4 15/16"0.313 Passed (L/921)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Dining Room Patio DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.6 1 - Uniform (PLF)0 to 6' 6"N/A 80.0 --Wall - Upper Level 2 - Uniform (PSF)4' 6" to 6' 6"15'20.0 -35.0 Snow - Main 3 - Uniform (PSF)0 to 6' 6"8'15.0 40.0 -Floor - Upper Level 4 - Point (lb)4' 6"N/A 844 -1444 Linked from: Bedroom #2 Window, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 9 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.05"1109 626/-67 1385 3120/-67 None 2 - Trimmer - SPF 4.50"4.50"3.16"1725 1566 1504 4795 None 3 - Trimmer - SPF 4.50"4.50"4.58"2534 1566 2835 6935 None 4 - Trimmer - SPF 1.50"1.50"1.50"726 584/-67 785 2095/-67 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5835 @ 7' 9 3/4"5738 (4.50")Passed (102%)--1.0 D + 0.75 L + 0.75 S (Adj Spans) Shear (lbs)2276 @ 4' 10 3/4"2872 Passed (79%)1.15 1.0 D + 1.0 S (Alt Spans) Moment (Ft-lbs)-2265 @ 7' 9 3/4"3946 Passed (57%)1.15 1.0 D + 0.75 L + 0.75 S (Adj Spans) Live Load Defl. (in)0.008 @ 5' 9 15/16"0.129 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.012 @ 5' 9 11/16"0.194 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 8" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 8" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Great Room Window RearMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 7 1/2"N/A 7.0 1 - Uniform (PSF)0 to 11' 7 1/2"8' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 11' 7 1/2"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)5' 3" to 11' 7 1/2"15'20.0 -35.0 Snow - Main 4 - Point (lb)0 N/A 844 -1444 Linked from: Bedroom #3 Window, Support 1 5 - Point (lb)5' 3"N/A 844 -1444 Linked from: Bedroom #3 Window, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 10 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.97"1346 878 683 2907 None 2 - Trimmer - SPF 3.00"3.00"1.97"1346 878 683 2907 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2516 @ 1 1/2"3825 (3.00")Passed (66%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1304 @ 1' 1/4"2498 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2714 @ 3' 3"3431 Passed (79%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.037 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.074 @ 3' 3"0.313 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Office WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 1 - Uniform (PSF)0 to 6' 6"6' 9"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 6' 6"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 6"3'20.0 -35.0 Snow - Main 5 - Uniform (PSF)6' to 6' 6"3'20.0 -35.0 Snow - Main 6 - Uniform (PSF)0 to 6"1'100.0 --Wall - Gable 7 - Uniform (PSF)6' to 6' 6"1'100.0 --Wall - Gable 8 - Point (lb)6"N/A 459 -289 Bedroom# 4 Window Support 1 9 - Point (lb)6'N/A 459 -289 Bedroom# 4 Window Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 11 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"1.50"479 785 1264 Blocking 2 - Stud wall - SPF 5.50"5.50"2.07"1011 1633 2644 Blocking 3 - Column - SPF 3.00"3.00"1.50"170 367 537 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2644 @ 12'7013 (5.50")Passed (38%)--1.0 D + 1.0 S (Adj Spans) Shear (lbs)1252 @ 11'2872 Passed (44%)1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-lbs)-2612 @ 12'3946 Passed (66%)1.15 1.0 D + 1.0 S (Adj Spans) Live Load Defl. (in)0.097 @ 6' 1/2"0.367 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.152 @ 6' 3/16"0.550 Passed (L/866)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD Member Pitch: 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 17' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' 8" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Drop Beam over Front Porch (H)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 19' 1"N/A 7.0 1 - Uniform (PSF)0 to 19' 1" (Front)4'20.0 35.0 Snow - Porch Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 12 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. •At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger •¹ See Connector grid below for additional information and/or requirements. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1600 581 1885 4066 See note ¹ 2 - Stud wall - LSL 5.50"5.50"1.57"1609 589 1887 4085 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3186 @ 3 1/2"4725 (1.50")Passed (67%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2156 @ 1' 3 3/8"9878 Passed (22%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)4572 @ 3' 9"18346 Passed (25%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.028 @ 3' 3"0.147 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.053 @ 3' 2 15/16"0.294 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 3" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer (H)MEMBER REPORT PASSED Connector: Simpson Strong-Tie Connectors Support Model Seat Length Top Nails Face Nails Member Nails Accessories 1 - Face Mount Hanger HHUS48 3.00"N/A 22-10d 8-10d None Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)3 1/2" to 6' 6"N/A 13.0 1 - Uniform (PSF)0 to 6' 6" (Front)4' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 6' 6" (Front)N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6" (Front)1'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 1' 9" (Front)15'20.0 -35.0 Snow - Main 5 - Uniform (PSF)3' 9" to 6' 6" (Front)15'20.0 -35.0 Snow - Main 6 - Point (lb)1' 9" (Front)N/A 345 -591 Linked from: Bed #4 WIC Window, Support 1 7 - Point (lb)3' 9" (Front)N/A 345 -591 Linked from: Bed #4 WIC Window, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 13 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. •At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger •¹ See Connector grid below for additional information and/or requirements. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"3.85"4148 912 5632 10692 Blocking 2 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"851 560 904 2315 See note ¹ All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)9780 @ 1' 2 3/4"13956 (5.50")Passed (70%)--1.0 D + 1.0 S (All Spans) Shear (lbs)8236 @ 2' 5 3/8"9878 Passed (83%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)14065 @ 3' 1 3/4"18346 Passed (77%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.189 @ 5' 11 5/8"0.274 Passed (L/696)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.336 @ 6' 3/16"0.549 Passed (L/392)--1.0 D + 1.0 S (Alt Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Overhang deflection criteria: LL (2L/480) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 7" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 12' 3" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer (V)MEMBER REPORT PASSED Connector: Simpson Strong-Tie Connectors Support Model Seat Length Top Nails Face Nails Member Nails Accessories 2 - Face Mount Hanger HHUS48 3.00"N/A 22-10d 8-10d None Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 2 1/2"N/A 13.0 1 - Uniform (PSF)0 to 3' (Front)1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)3' to 12' 6" (Front)2'15.0 40.0 -Floor - Upper Level 3 - Uniform (PSF)0 to 3' (Front)1'20.0 -35.0 Snow - Porch 4 - Uniform (PLF)0 to 3' 1 3/4" (Front)N/A 80.0 --Wall - Upper Level 5 - Uniform (PSF)0 to 3' (Front)8' 6"20.0 -35.0 Snow - Main 6 - Point (lb)2' 10 1/4" (Front)N/A 2080 -3640 Girder 7 - Point (lb)3' 1 3/4" (Front)N/A 1609 589 1887 Linked from: Flush Beam over Foyer (H), Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 14 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 4.50"4.50"4.21"4493 912 6179 11584 None 2 - Trimmer - SPF 3.00"3.00"1.50"331 -525 856 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)10672 @ 3"11419 (4.50")Passed (93%)--1.0 D + 1.0 S (All Spans) Shear (lbs)559 @ 1' 2"7902 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1179 @ 3' 1 1/2"11985 Passed (10%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 3' 1 1/2"0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.023 @ 3' 1 1/2"0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 2" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 2" o/c unless detailed otherwise. Main Level, Foyer Entry DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 1 1/2"N/A 10.4 1 - Uniform (PSF)0 to 6' 1 1/2"5'20.0 -35.0 Snow - Porch 2 - Point (lb)2"N/A 4148 912 5632 Linked from: Flush Beam over Foyer (V), Support 1 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 15 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"2.16"1977 3508 828 6313 Blocking 2 - Column - SPF 5.50"5.50"1.57"1180 2802 76 4058 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5484 @ 4"13956 (5.50")Passed (39%)--1.0 D + 1.0 L (All Spans) Shear (lbs)4079 @ 1' 5 3/8"8590 Passed (47%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)11037 @ 5' 6"15953 Passed (69%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.242 @ 5' 8 3/8"0.271 Passed (L/538)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.349 @ 5' 8 1/8"0.542 Passed (L/372)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 9' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 6" o/c unless detailed otherwise. Main Level, Flush Beam over Foyer/Dining Room (H)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 6"N/A 13.0 1 - Uniform (PSF)7' 6" to 11' 6" (Front)8' 3"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)1' 3" to 7' 6" (Front)13'15.0 40.0 -Floor - Upper Level 3 - Uniform (PSF)0 to 1' 3" (Front)14'15.0 40.0 -Floor - Upper Level 4 - Uniform (PSF)7' 6" to 11' 6" (Front)3'15.0 40.0 -Floor - Stairs 5 - Point (lb)1' 3" (Front)N/A 851 560 904 Linked from: Flush Beam over Foyer (V), Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 16 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Column - SPF 3.00"3.00"1.50"822 2080 2902 Blocking 2 - Column - SPF 3.00"3.00"1.50"822 2080 2902 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2902 @ 1 1/2"7613 (3.00")Passed (38%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2146 @ 1' 1/2"6872 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)5446 @ 4'10422 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.126 @ 4'0.194 Passed (L/736)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.176 @ 4'0.387 Passed (L/528)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' o/c unless detailed otherwise. Main Level, Beam over PantryMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 8'N/A 10.4 1 - Uniform (PSF)0 to 8' (Front)13'15.0 40.0 Floor - Upper Level Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 17 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None 2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 10" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 9" o/c unless detailed otherwise. Main Level, 16' Garage Door OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 1 - Uniform (PSF)0 to 16' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PLF)0 to 16' 9"N/A 100.0 -Wall - Gable Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 18 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None 2 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1197 @ 1 1/2"3825 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)872 @ 1' 2 1/4"3493 Passed (25%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2470 @ 4' 4 1/2"5306 Passed (47%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.025 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.064 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, 8' Garage Door OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Snow Loads Location (Side)Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 1 - Uniform (PSF)0 to 8' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PLF)0 to 8' 9"N/A 100.0 -Wall - Gable Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 19 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"448 45 198 691 None 2 - Trimmer - SPF 1.50"1.50"1.50"315 45 130 490 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)646 @ 0 1913 (1.50")Passed (34%)--1.0 D + 1.0 S (All Spans) Shear (lbs)116 @ 1' 4 1/4"2872 Passed (4%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)269 @ 1' 7/16"3946 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.001 @ 1' 1"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Bath WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 1 - Uniform (PSF)0 to 2' 3"1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 2' 3"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 2' 3"1'100.0 --Wall - Gable 4 - Uniform (PSF)3" to 2' 3"3'20.0 -35.0 Snow - Main 5 - Point (lb)3"N/A 188 -118 Linked from: Owner's Bath Window, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 20 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"581 370 540 1491 None 2 - Trimmer - SPF 1.50"1.50"1.50"581 370 540 1491 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1263 @ 0 1913 (1.50")Passed (66%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)529 @ 10 3/4"2872 Passed (18%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)974 @ 1' 6 1/2"3946 Passed (25%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.006 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 1" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Garage Mudroom Service DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 1 - Uniform (PSF)0 to 3' 1"6'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 3' 1"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 1"9'20.0 -35.0 Snow - Main 4 - Uniform (PSF)0 to 3' 1"1'20.0 -35.0 Snow - Garage Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 21 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"426 65 171 662 None 2 - Trimmer - SPF 1.50"1.50"1.50"426 65 171 662 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)603 @ 0 1913 (1.50")Passed (32%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)270 @ 10 3/4"2872 Passed (9%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)490 @ 1' 7 1/2"3946 Passed (12%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.001 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.003 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 3" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 3" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Great Room Side Windows (2)MEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 7.0 1 - Uniform (PSF)0 to 3' 3"1'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 3' 3"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 3"3'20.0 -35.0 Snow - Main 4 - Uniform (PSF)0 to 3' 3"1'100.0 --Wall - Gable Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 22 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None 2 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1501 @ 0 1913 (1.50")Passed (78%)--1.0 D + 1.0 L (All Spans) Shear (lbs)694 @ 10 3/4"2498 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1251 @ 1' 8"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.007 @ 1' 8"0.111 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.009 @ 1' 8"0.167 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 4" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 4" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Main Level, Mudroom OpeningMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 4"N/A 7.0 1 - Uniform (PSF)0 to 3' 4"16' 3"15.0 40.0 Floor - Upper Level Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 23 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"813 2041 2854 None 2 - Trimmer - SPF 1.50"1.50"1.50"387 992 1379 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2854 @ 0 3806 (1.50")Passed (75%)--1.0 D + 1.0 L (All Spans) Shear (lbs)551 @ 1' 10"6872 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1053 @ 1' 2 11/16"10422 Passed (10%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 3 13/16"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.008 @ 1' 3 13/16"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c unless detailed otherwise. Lower Level, Bath DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 10.4 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level 2 - Uniform (PLF)0 to 3"N/A 90.0 -Wall - Main Level 3 - Uniform (PSF)0 to 3"16' 3"15.0 40.0 Floor - Upper Level 4 - Point (lb)3"N/A 418 1083 Linked from: Mudroom Opening, Support 1 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 24 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 5.50"5.50"4.46"3761 7545 558 11864 None 2 - Trimmer - SPF 3.00"3.00"1.50"557 1429 -1986 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)11306 @ 4"13956 (5.50")Passed (81%)--1.0 D + 1.0 L (All Spans) Shear (lbs)973 @ 1' 3"6872 Passed (14%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1787 @ 2' 3"10422 Passed (17%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.015 @ 2' 3"0.128 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.020 @ 2' 3"0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 4" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 4" o/c unless detailed otherwise. Lower Level, Beam over Hallway/Mech RoomMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3 1/2"N/A 10.4 1 - Uniform (PSF)0 to 4' 3 1/2" (Front)17' 6"15.0 40.0 -Floor - Main Level 2 - Point (lb)0 (Front)N/A 3147 5970 558 Linked from: Bar FLR Beam, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 25 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.46"1223 1918 3141 None 2 - Trimmer - SPF 3.00"3.00"2.41"1161 1918 3079 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3141 @ 1 1/2"3825 (3.00")Passed (82%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1999 @ 4' 5 3/4"2498 Passed (80%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2972 @ 2' 8 7/8"3431 Passed (87%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.034 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.057 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Lower Level, Bedroom #5 WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 1 - Uniform (PSF)0 to 5' 6"7' 6"15.0 40.0 Floor - Main Level 2 - Uniform (PSF)0 to 5' 6"1'90.0 -Wall - Main Level 3 - Uniform (PSF)0 to 1'9' 6"15.0 40.0 Floor - Upper Level 4 - Uniform (PSF)0 to 1'1'80.0 -Wall - Upper Level 5 - Uniform (PSF)4' 6" to 5' 6"9' 6"15.0 40.0 Floor - Upper Level 6 - Uniform (PSF)4' 6" to 5' 6"0 80.0 -Wall - Upper Level 7 - Point (lb)1'N/A 430 713 Linked from: Kitchen Window, Support 1 8 - Point (lb)4' 6"N/A 430 713 Linked from: Kitchen Window, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 26 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.95"1966 2990 581 5537 None 2 - Trimmer - SPF 3.00"3.00"2.53"2735 2990 1913 7638 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)6412 @ 6' 4 1/2"7613 (3.00")Passed (84%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1966 @ 1' 1/2"6872 Passed (29%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4348 @ 3' 3"10422 Passed (42%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.066 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.098 @ 3' 3"0.313 Passed (L/763)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c unless detailed otherwise. Lower Level, Family Room Patio DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.4 1 - Uniform (PSF)0 to 6' 6"8'15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 6' 6"1'90.0 --Wall - Main Level 3 - Uniform (PSF)0 to 6' 6"7'10.0 40.0 -Floor - Deck 4 - Point (lb)0 N/A 1022 1040 581 Linked from: Dining Room Patio Door, Support 1 5 - Point (lb)6' 6"N/A 1791 1040 1913 Linked from: Dining Room Patio Door, Support 2 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 27 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.73"2928 3011 1860 7799 None 2 - Trimmer - SPF 3.00"3.00"1.95"3304 3011 2479 8794 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)7421 @ 8' 4 1/2"11419 (3.00")Passed (65%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)6914 @ 7' 5 1/2"10898 Passed (63%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)15274 @ 5' 2 15/16"20312 Passed (75%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.164 @ 4' 3 11/16"0.275 Passed (L/602)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.296 @ 4' 3 11/16"0.412 Passed (L/335)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c unless detailed otherwise. Lower Level, Family Room WindowMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 14.5 1 - Uniform (PSF)0 to 8' 6"8' 6"15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 8' 6"1'90.0 --Wall - Main Level 3 - Point (lb)2' 4"N/A 1725 1566 1504 Linked from: Great Room Window Rear, Support 2 4 - Point (lb)6' 2"N/A 2534 1566 2835 Linked from: Great Room Window Rear, Support 3 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 28 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"469 894 1363 None 2 - Trimmer - SPF 1.50"1.50"1.50"469 894 1363 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1362 @ 0 1913 (1.50")Passed (71%)--1.0 D + 1.0 L (All Spans) Shear (lbs)475 @ 10 3/4"2498 Passed (19%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)937 @ 1' 4 1/2"3431 Passed (27%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.005 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c unless detailed otherwise. •Applicable calculations are based on NDS. Lower Level, WIC DoorMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Loads Location (Side)Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 7.0 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level 2 - Uniform (PLF)0 to 2' 9"N/A 90.0 -Wall - Main Level Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 29 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 3 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"4.11"2997 6183 270 9450 Blocking 2 - Stud wall - SPF 5.50"5.50"4.09"3147 5970 558 9675 Blocking All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)9180 @ 4"12272 (5.50")Passed (75%)--1.0 D + 1.0 L (All Spans) Shear (lbs)7844 @ 7' 1/8"12884 Passed (61%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)19919 @ 4' 11 13/16"23930 Passed (83%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.155 @ 4' 3 3/4"0.195 Passed (L/603)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.234 @ 4' 3 7/8"0.390 Passed (L/400)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c unless detailed otherwise. Lower Level, Bar FLR BeamMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 10/9/2019. Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 5 1/2"N/A 19.5 1 - Uniform (PSF)0 to 8' 5 1/2" (Front)14'15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 8' 5 1/2" (Front)1'90.0 --Wall - Main Level 3 - Uniform (PSF)0 to 5' 7" (Front)17' 6"15.0 40.0 -Floor - Upper Level 4 - Point (lb)5' 7" (Front)N/A 1977 3508 828 Linked from: Flush Beam over Foyer/Dining Room (H), Support 1 Forte v5.5, Design Engine: V7.3.2.4 10/17/2019 9:22:08 AM Page 30 of 30 5697 Upper 179th St W, Lakeville, MN.4te Forte Software Operator Alex Schoenbauer, EWP Specialist Lyman Lumber Company (952) 470-4803 alex_schoenbauer@lymanlumber.com Job Notes Topaz - Payton XL Bowe & Thiel Residence 5697 Upper 179th St W, Lakeville, MN 10/17/2019; #23809 1 1 / 0 4 / 1 9 X K P