HomeMy WebLinkAboutItem 3City of Lakeville
Community & Economic Development
Memorandum
To: Mayor and City Council
Justin Miller, City Administrator
From: Daryl Morey, Planning Director
Date: November 22, 2019
Subject: November 25, 2019 City Council Work Session
CMU District Discussion
Background:
On July 13th the City Council, Planning Commission, and City staff went on a bus tour of transit
oriented development areas in three Twin Cities suburbs (Eden Prairie, Maple Grove, and St.
Louis Park). The Planning Commission and City Council shared their impressions from the bus
tour at work sessions held on September 5th and 23rd, respectively.
Planning Consultant Daniel Licht of TPC has prepared an outline of three proposed zoning
districts to implement the CMU land uses designated in the approved 2040 Comprehensive
Plan. These districts are described in his November 14th memo. The Planning Commission
discussed the CMU related districts at their November 21st work session.
Action Requested:
Provide feedback on the proposed CMU related district uses and performance standards,
which will be included in the next Zoning Ordinance update.
Attachment:
• November 21st Planning Commission draft work session minutes
• November 14th TPC memo and exhibits
CITY OF LAKEVILLE
PLANNING COMMISSION WORK SESSION MINUTES
November 21, 2019
Alternate Chair Brooks Lillehei called the work session to order at 6:40 p.m.
Members Present: Karl Drotning, Jenna Majorowicz, Jason Swenson, and Jeff Witte
Members Absent: Chair Pat Kaluza, Vice Chair Scott Einck, Jason Kelvie, and Ex-
Officio Mike Lamm
Staff Present: Planning Director Daryl Morey, Associate Planners Kris Jenson and
Frank Dempsey, and Daniel Licht, TPC
Others Present: Allison Krueger, Mark Hrubes, and Brian Bross – Joy Court
neighborhood; Jim Kellison, Kelco Services; and Amanda Johnson, Summit
Management (owner of Connelly Manufactured Home Park)
Corridor Mixed Use (CMU) District Discussion
Mr. Licht reviewed and summarized the proposed M-1 District.
Mr. Kellison stated that he represents an apartment developer that has a purchase
agreement for the undeveloped property located south of Fleet Farm. He stated the
creation of the M-1 District is a positive step. He expressed concern about the 2.0 stall
per dwelling unit parking requirement as the project they would like to build is not likely
to have any three bedroom units, and would have a mix of studio, one bedroom, and
two bedroom units. They would prefer to have the parking requirement tied to the
number of bedrooms and not have to construct a large parking lot with unused spaces.
He agrees with the one covered parking space requirement but would like to ability to
provide proof of parking to meet the requirements.
Commissioner Drotning noted that a few years ago the City reduced the parking
requirements for multiple-family units slightly. Mr. Licht reviewed the previous
requirements compared to what is currently in the ordinance. Mr. Licht added that the
proposed districts would include opportunity to reduce required parking based on a
use-specific parking study.
Allison Krueger, 17296 Joy Court, expressed concern about possible six story buildings
and the setbacks to property lines adjacent to single family neighborhoods.
Director Morey explained the criteria for approval of a conditional use permit (CUP) for
taller structures, including compatibility with adjacent uses. He noted that the 30 foot
setback proposed for the M-1 District adjacent to R Districts matches the current
Planning Commission Work Session Minutes – November 21, 2019 Page 2
setback requirement in the RH districts. He also noted that a landscape buffer would be
required on the apartment site adjacent to the existing single family homes.
Mr. Licht discussed the CUP process and the ability for the City to either limit the height
or add requirements based on the conditions of the site and the criteria for consideration
of a conditional use permit. Mr. Licht noted that the area around the Kenrick Avenue
Park and Ride is primarily one and two story commercial structures with abutting single
family residential uses to the east and a six story structure would not be compatible with
the area; a six story structure is more likely to be compatible near the I-35/CSAH 70
interchange.
Commissioners discussed the appropriateness of six story buildings adjacent to single
family homes within the M-1 District. Commissioner Lillehei suggested allowing four
stories, consistent with the Interstate Storage building on the west side of I-35.
Commissioner Witte stated that he preferred allowing six story buildings to provide
flexibility. Mr. Licht suggested that a condition be added that sites within the M-1 District
proposed for a height greater than 4 stories would be prohibited from abutting an RS
(single family) zoning district. The consensus of the Planning Commission was to allow
4 story residential buildings in the M-1 and M-2 Districts, up to 6 stories within the M-1
District by CUP except when abutting an RS District.
Mr. Kellison asked how a three story building over a mostly underground parking garage
would be defined. Mr. Licht explained how the ordinance measures building height,
based on average grade and average roof pitch. Director Morey noted that staff would
need to look further at the typical height of a story, given the market trend toward
apartment buildings with higher ceilings and pitched roofs. Ms. Johnson noted that in
their apartment projects, the typical ceiling height is now nine to 10 feet, so she
supports staff examining the allowed building height.
Mark Hrubes, 17281 Joy Court, expressed concern about the removal of the natural
barrier of mature trees that can exist on a property when the Zoning Ordinance allows
new trees at a height of only eight feet.
Brian Bross, 17289 Joy Court, expressed concern about the setback of apartment
buildings to single family areas as well as the greenspace/play area requirements for
recreation of the apartment residents as there is a lack of public parks in their
neighborhood.
Mr. Kellison noted that the 2040 Land Use Map indicates that the Corridor Mixed Use
district would have a density range of 26 to 45 dwelling units per acre but that the
proposed M-1 district shows a maximum density of 22 dwelling units per acre. He added
that the majority of units within a typical building they construct are studio and one
bedroom units, whereas 20 years ago the majority were two and three bedroom units.
Ms. Johnson concurred with Mr. Kellison’s statement about increasing the allowed
density as family size continues to shrink and the demand is for smaller units.
Commissioner Witte stated that additional density should be allowed for apartment
Planning Commission Work Session Minutes – November 21, 2019 Page 3
projects near transit. Mr. Licht said that increasing density from 22 dwelling units per
acre to 26 dwelling units per acre would potentially add 30 dwelling units to the Fleet
Farm site. Commissioner Swenson noted that the ability to develop 26 dwelling units
per acre is contingent upon meeting all of the other applicable performance standards in
the zoning district. The consensus of the Planning Commission was to increase the
allowed density within the M-1 District to 26 dwelling units per acre.
Mr. Licht reviewed the proposed M-2 and RM-3 districts, to which the Planning
Commission was generally supportive and offered no proposed changes at this time.
Planning Director Morey stated that the next steps in the process would be for City staff
to present the proposed district information to the City Council at a work session on
November 25, 2019. Following the comments by the City Council, City staff would work
to draft formal ordinance language for consideration at a future work session. City staff
is also reviewing the Zoning Ordinance comprehensively to identify any additional
issues to be reviewed as part of the Phase 2 update of the City’s development
regulations after adoption of the 2040 Comprehensive Plan.
The work session adjourned at 8:00 p.m.
Respectfully submitted,
Daryl Morey, Planning Director
3601 Thurston Avenue
Anoka, MN 55303
763.231.5840
TPC@PlanningCo.com
1
MEMORANDUM
TO: Daryl Morey
FROM: D. Daniel Licht, AICP
DATE: 14 November 2019
RE: Lakeville – Zoning Ordinance; Corridor Mixed Use development standards
TPC FILE: 135.01
BACKGROUND
The 2040 Lakeville Comprehensive Plan has been approved by the Metropolitan Council and
adopted by the City Council. City staff has initiated work on implementation of the plan with
updates to the Zoning Ordinance. A major focus of the implementation effort will be
formulation of allowed uses and development standards for the newly created Corridor Mixed
Use (CMU) land use category. This process has involved the following steps to date:
Bus tour of regional community examples on 23 July 2019
Planning Commission work session on 5 September 2019
City Council work session on 23 September 2019
The Planning Commission and City Council work sessions held in September 2019 were for the
purpose of City officials to discuss impressions from the bus tour and provide direction to City
staff as to preferences in the formulation of development regulations for CMU land uses. City
staff has used this information together with the policies of the 2040 Comprehensive Plan and a
2016 multiple family zoning study to prepare an outline of the zoning districts necessary to
implement the CMU land uses.
Exhibits:
Planning Commission work session minutes of 5 September 2019
City Council work session minutes of 23 September 2019
2040 Land Use Plan
Summary of bus tour communities
Outline of Proposed CMU Districts
2
ANALYSIS
The primary use of the CMU land use category will be within the Cedar Avenue Bus Rapid
Transit Corridor (Red Line) to provide for future development of high density residential, mixed
use, and commercial land uses in support of planned transit services. The Cedar Avenue
corridor includes not only designation of future CMU land uses, but also low-to-medium,
medium, and medium-to-high residential land uses within ½ mile of Cedar Avenue.
CMU land uses have also been designated on the land use plan as individual locations within
the I-35 corridor based on recommendations of the Economic Development Commission,
Planning Commission and City Council to identify opportunities for high density residential land
uses within or adjacent to existing and planned commercial uses in proximity to existing and
planned transit facilities within the future Orange Line Bus Rapid Transit extension.
City staff has outlined three proposed zoning districts to implement the CMU land uses as
designated by the 2040 Comprehensive Plan:
M-1 District. The M-1, Mixed Use I-35 Corridor District is to be designated for sites
adjacent to the I-35 corridor for CMU land uses. The proposed district mirrors the
allowed uses and development standards of the C-3, General Commercial District to
emphasize the intended character of the development consistent with surrounding land
uses guided and zoned for commercial land uses. The M-1 District makes allowance for
multiple family dwellings (stand-alone or mixed use buildings) as a conditional use. The
development standards for multiple family dwellings within the proposed M-1 District
are based on those implemented for the recent multiple family residential development
Lee Lake Commercial located at I-35 and CSAH 46 that reflected the recommendations
of the Economic Development Commission and Planning Commission from the 2016
multiple family housing study.
o Development of multiple family dwellings would be subject to approval of a
conditional use permit. The conditional use permit process allows the Planning
Commission and City Council the ability to review a proposed use at a specific
location with regards to compatibility with surrounding land uses, adequate
access, and adequate utility infrastructure.
o Residential density would be limited to a base 18 dwelling units per acre except
that locations within ½ mile of planned transit facilities would be allowed to
develop at 22 dwelling units per acre. Senior housing would be allowed to
develop at a density of 43 dwelling units per acre.
o Setbacks are proposed to be the same as required in the C-3 District including a
30 foot buffer setback from residential zoning districts. The 30 foot buffer yard
will additionally be required to be landscaped in accordance with the provisions
3
established for residential subdivisions abutting major collector and arterial
streets.
o Building height is limited to 3 stories or 35 feet. An increase to 6 stories or 65
feet as allowed within the C-3 District by approval of a conditional use permit is
also proposed to be included within the M-1 District.
o Exterior finish materials for both commercial and residential structures (or mixed
use buildings) will be required to meet the same requirements as commercial
structures within the C-3 District to maintain consistency with the character of
existing and planned surrounding uses.
o Off-street parking requirements for commercial uses will be as provided for by
the Zoning Ordinance. Multiple family dwellings will be required to provide 2.5
off-street parking stalls per dwelling unit unless the number of bedrooms per
dwelling unit is 2.0 or less, which would only be required to provide 2.0 stalls per
dwelling unit. A reduction in the number of off-street parking stalls would be
allowed by conditional use permit based on a site-specific traffic study that
considers proximity to transit facilities. A minimum of 1 off-street parking stall is
to be required within an enclosed space either in the form of a garage beneath
the building or a ramp structure attached to the building.
o The M-1 District includes an exception for affordable housing units from the
enclosed off-street parking requirements. The proposed performance standards
already include density bonuses that may make affordable housing units more
feasible. Also, because the M-1 District is being applied to locations previously
planned for commercial use, the standards for landscaping and open space are
already minimized compared to that required within a residential district
allowing multiple family uses.
M-2 District. The M-2, Mixed Use Cedar Corridor District is to be designated for sites
adjacent to the Cedar Avenue corridor for CMU land uses.
o Timing of development of the CMU land uses within the corridor is intended by
the City to be dependent upon future regional commitments to provide for
transit infrastructure and services. The purpose statement of the M-2 District
indicates that parcels zoned M-2 District will not be removed from the RAO,
Rural Agriculture Overlay District until such time as these transportation
commitments are secured. The Planning Commission should discuss this issue as
the timing of the 195th Street station may not occur until 2040 or later. The
question is, therefore, would the City allow development at the intensity
provided for by the M-2 District without the availability (or commitment to)
transit service within the Cedar Avenue corridor? On the bus tour, Arbor Lakes
in Maple Grove was visited that includes a range of higher density residential
4
uses with regional retail and office uses in an area served only by a transit park
and ride facility, but accessible to regional principal arterial roadways.
o Proposed uses include multiple family residential dwellings as a permitted use.
Commercial land uses are similar to the non-automotive oriented uses allowed
in the C-3 District excluding drive through facilities for convenience food uses,
motor fuel facilities, and car washes. Data centers, religious facilities, and
theaters are also not included in the proposed M-2 District.
o There is to be no minimum lot requirements for commercial land uses.
o Residential density is to be allowed to be up to 26 dwelling units per acre similar
to the development character of Avonlea Village Green and Edison at SBF.
o Setbacks are required to be 30 feet from major collector and arterial streets and
10 feet from local streets, side yards, or rear yards to encourage a building
forward streetscape and maximize the development of individual lots.
o Building height is to be limited to 4 stories or 48 feet, which is the height of the
market rate apartment buildings seen in the Arbor Lakes area of Maple Grove.
o Exterior finish materials for both commercial and residential structures (or mixed
use buildings) will be required to meet the same requirements as commercial
structures within the C-3 District to maintain consistency with the character of
existing and planned surrounding uses and to maximize sustainability in
consideration of allowed density.
o Off-street parking requirements for commercial uses will be as provided for by
the Zoning Ordinance. Multiple family dwellings will be required to provide 2.0
off-street parking stalls per with a minimum of 1 off-street parking stall to be
provided within an enclosed space either in the form of a garage beneath the
building or a ramp structure attached to the building. Surface parking will be
required to be located within a side or rear yard. Reductions in required parking
may be considered by conditional use permit that would be dependent on a
parking demand study for a specific development.
o The proposed M-2 District includes a 160 square foot/dwelling unit open space
requirement for residential uses. The required open space is intended to be
common areas in the form of yards, interior courtyards, or rooftop spaces. The
open space requirement is to be considered further as part of a future update of
the Parks, Trails, and Open Space Plan to evaluate the need for public open
space within the Cedar Avenue corridor based on the land uses now planned
that were not designated when the document was last updated in 2015.
5
o The proposed M-2 District would include local street standards specific to this
district (and the RM-3 District outlined below) reflecting the requirements
established for the Spirit of Brandtjen Farm and Avonlea developments.
o The streetscape within the M-2 District is to include 6 foot concrete sidewalks on
both sides of local streets, boulevard trees, and pedestrian scale street lighting
to promote a pedestrian oriented environment.
o The M-2 District includes exceptions for affordable housing units from the
requirements for exterior finish materials, enclosed parking, landscaping, and
open space consistent with similar provisions within the City’s existing medium
density and high density residential zoning districts.
RM-3 District. City staff has also drafted an outline for a proposed RM-3, Medium
Density Residential District intended to allow for development of detached townhome,
twin-home, row townhome, and back-to-back townhomes within the Cedar Avenue
corridor that are designated for Medium-to-High Density Residential Uses on the 2040
Land Use Plan that is distinguished from the RM-2 District as follows:
o The minimum lot are per unit requirement is reduced from 5,000 square feet per
dwelling unit to 3,800 square feet per dwelling unit to allow for development at
up the maximum density described by the 2040 Comprehensive Plan for the
Medium-to-High Density Residential land use category.
o Exterior material requirements are to be the same within the RM-3 District as
required within the RST-2 District with brick/stone required on all elevations
together with use of at least 2 other materials (with the allowance of split faced
concrete block, cement fiberboard and engineered wood to meet the brick,
stone, stucco requirement on the side and rear elevations).
o Setbacks to major collector and arterial streets are to be reduced from 50 feet to
30 feet. Setbacks to local streets are to be reduced to 10 feet (with 25 feet to a
garage face). The proposed setbacks are consistent with the development
standards established for Spirit of Brandtjen Farm and Avonlea and will increase
the area available for development.
o The proposed RM-3 District would include local street standards reflecting the
requirements established for the Spirit of Brandtjen Farm and Avonlea
developments.
o The streetscape within the RM-3 District is to include 5 foot concrete sidewalks
on both sides of local streets, boulevard trees, and pedestrian scale street
lighting to promote a pedestrian oriented environment.
6
Areas within the Cedar Corridor designated on the 2040 Land Use Plan guided for Low-
to-Medium and Medium Density Residential land uses will continue to be zoned RST-2
and RM-1 District, respectively. Development of Low-to-Medium and Medium Density
Residential land uses within these zoning existing standards will provide for a desirable
transition from the more intensive transit oriented use nodes guided for CMU or
Medium-to-High Density residential uses adjacent to Cedar Avenue and lower density
areas that exist or are planned in Lakeville to the west (and Farmington to the east).
CONCLUSION
A Planning Commission work session is to be held on 21 November 2019 to be followed by a
City Council work session on 25 November 2019 to discuss the proposed outline for zoning
districts as a basis for development regulations specific to CMU land uses.
c. Justin Miller, City Administrator
David Olson, Community and Economic Development Director
M-1, Mixed Use I-35 Corridor M-2, Mixed Use Cedar Corridor RM-3, Medium Density Residential District
Purpose The purpose of the M-1 District is to provide for development of
commercial areas with opportunity for incorporating multiple family
dwellings within areas guided by the Comprehensive Plan for Corridor
Mixed Uses adjacent to the I-35 corridor.
The purpose of the M-2 District is to provide for development of commercial
and high density residential uses that enhance and contribute to the City’s
identity within the Cedar Avenue corridor guided by the Comprehensive Plan
for Corridor Mixed Uses that will utilize and support planned future transit
services. These areas are not to develop with urban uses until such time as
commitments are made to construction of transit infrastructure and a timetable
for transit services are established.
The purpose of the RM-3 district is to establish a medium density
residential neighborhood within the Cedar Corridor planning district
established by the Comprehensive Plan and I-35 corridor meeting the
following objectives: A. Creation of a cohesive medium-to-high density
neighborhood that provides attractive living environments and
contributes to the city’s identity; B. Provide attractive and durable
medium density housing options as a means of addressing the city’s life
cycle housing needs; Preservation of natural landforms, open spaces,
greenways for scenic enjoyment and recreational use through the
regulation of medium density residential land use; Allows for the
subdivision of two-family and townhome base lots to permit individual
private ownership of a single dwelling within such a structure at densities
that benefit from and support future transit services.
Permitted
Uses
Banks, offices
Commercial recreation, indoor
Funeral homes and mortuaries
Government buildings, City of Lakeville
Hotels
Instructional classes
Pawnshops
Private clubs or lodges
Public garages and parking lots
Restaurants, general
Retail businesses
Service businesses, on and off site
Data centers
Fitness centers and health clubs
Brew on premises/brewpub
Banks, Offices
Commercial recreation, indoor
Government buildings, City of Lakeville
Hotels
Instructional classes
Multiple family dwellings (stand-alone or mixed use bldgs.)
Private clubs or lodges
Public garages and parking lots, City of Lakeville
Residential facilities serving 16 or fewer persons
Restaurants, general
Retail businesses
Service businesses, on and off site
Fitness centers and health clubs
Brew on premises/brewpub
More than 1 principal building on a base lot
Parks and trails, City of Lakeville
Public garages and parking lots, City of Lakeville
Residential facilities serving 16 or fewer persons
Townhomes, detached
Townhomes with no more than 6du in a row or 12du back-to-back
Two family dwellings
Conditional
Uses
Auto repair, minor and major
Bottled gas sales
Commercial recreation, outdoor
Community preschool, latchkey, adult ed./daycare
Convenience restaurants
Essential services
Government buildings, transit facilities other than City
Manufactured home parks
Motor fuel sales/commercial car washes
Multiple family dwellings (stand-alone or mixed use bldgs.)
Multiple principal buildings
Nursing homes
Personal wireless service antennas
Principal bldg. height up to 6 stories
Religious institutions/ Theaters, indoor
Residential facilities serving 16 or fewer persons
Veterinary clinics/commercial kennels/pet shops
Microdistilleries/small breweries
Commercial recreation, outdoor
Community preschool, latchkey, adult ed.
Convenience restaurants w/out drive through
Daycare facilities
Essential services
Government buildings, transit facilities other than City
Manufactured home parks
Multiple principal buildings
Nursing homes
Personal wireless service antennas
Residential facilities serving 16 or fewer persons
Veterinary clinics/commercial
Commercial kennels
Microdistilleries with tasting rooms
Small breweries with tap rooms
Daycare facilities
Essential services
Government buildings, transit facilities other than City
Public/quasi-public recreation facilities
Public/private elementary, middle, and senior high schools
Religious institutions
Manufactured home parks
Parks and trails other than City of Lakeville
Personal wireless service antennas
Social services accessory to a religious facility
Residential
Density
1 du/2,500sf.
1 du/2,000sf. within ½ mile of planned transit facilities
1 du/1,000sf. (senior housing)
1 du/1,675sf.
1 du/1,000sf. (senior housing)
1 du/3,800sf.
M-1, Mixed Use I-35 Corridor M-2, Mixed Use Cedar Corridor RM-3, Medium Density Residential District
Lot
Requirements
Minimum lot area: 20,000sf.
Minimum lot width: 100ft.
None None
Setbacks Right-of-way 30ft. Right-of-way 10ft. or 30ft. abutting major collector or arterial street Right-of-way 10ft. or 30ft. abutting major collector or arterial street
Side 10ft. or 30ft. abutting a R District Side 10ft. Side: 10ft./14ft. between bldgs.
Rear 10ft. or 30ft. abutting a R District Rear 10ft. Rear: 10ft./14ft. between bldgs.
Garage face 25ft.
Building
Height
3 stories or 35ft. or up to 6 stories and 65ft. by CUP 4 stories or 48ft. 3 stories or 35ft.
Exterior
Finish
Min. 3 Grade A materials
Min. 65% Grade A materials
Not more than 35% Grade B or C materials
Not more than 10% Grade D materials
Min. 3 Grade A materials
Min. 65% Grade A materials
Not more than 35% Grade B or C materials
Not more than 10% Grade D materials
Min 25% brick/stone for all elevations
Not more than 75% of any elevation other material
Not more than 60% of all elevations other material
Off-Street
Parking
Commercial uses as required by Sec. 11-19-13
Multiple Family:
2.5 stalls/du when bedrooms > 2.0/du
2.0 stalls/du when bedrooms < 2.0/du.
Reduction in stalls by CUP based on site specific parking study
based on proximity to transit.
Min. 1 stall enclosed below or attached to structure
Commercial uses as required by Sec. 11-19-13
Multiple Family:
2.0 stalls/du.
Min. 1 stall enclosed below or attached to structure
Reduction in stalls by CUP based on site specific parking study based on
proximity to transit.
Parking shall be located in side/rear yards
Joint parking arrangements encouraged
2.0 stalls/du.
Must be within attached garage having area of 420sf.
0.25 stall guest parking required on-street/private drive/parking area
Residential
Open Space
Park dedication requirements
A residential buffer yard shall be required in yards abutting residential
districts.
160sf./du. (common lawns, courtyards, patios, rooftop spaces) in addition to
park dedication requirements
Park dedication requirements
Streets All streets: 10-4-3.P of Subdivision Ordinance Major collector and arterial streets: 10-4-3.P of Subdivision Ordinance
Local commercial street: 80ft. ROW/44ft. section w/ on-street parking
Local residential street:
60ft. ROW/32ft. section w/ on-street parking one side
52ft. ROW/28ft. section w/ on-street parking one side
Private drive: 20ft. posted as fire lane
Major collector and arterial streets: 10-4-3.P of Subdivision Ordinance
Local residential street:
60ft. ROW/32ft. section w/ on-street parking one side
52ft. ROW/28ft. section w/ on-street parking one side
Private drives: 24ft. section limited to 6du/1 structure per side
Sidewalks 6ft. concrete both sides of streets 6ft. concrete both sides of streets 5ft. concrete both sides of streets
Trails 10ft. asphalt trails designated on Parks, Trails, and Open Space Plan 10ft. asphalt trails designated on Parks, Trails, and Open Space Plan 10ft. asphalt trails designated on Parks, Trails, and Open Space Plan
Streetscape Landscaping within yards abutting ROW
Standard street lighting
Landscaping within yards abutting ROW.
Shade trees required within boulevards along local streets
Standard street lighting along major collector/arterial streets
Pedestrian scale street lighting along local streets
Landscaping within yards abutting ROW
Shade trees required within boulevards along local streets
Standard street lighting along major collector/arterial streets
Pedestrian scale street lighting along local streets
Transitional
Housing
None None None
Affordable
Housing
Exempt from requirements for:
Exterior finish
Enclosed parking
Minimum landscaping
Open space
Exempt from requirements for:
Exterior finish
Enclosed parking
Minimum landscaping
Open space
Exempt from requirements for:
Exterior finish
Enclosed parking
Minimum landscaping
Open space
CITYOFLAKEVILLE
PLANNING COMMISSION WORKSESSION MINUTES
September 5, 2019
Chair Kaluza called the work session toorder at 6:40 p.m.
MembersPresent: Chair Pat Kaluza, Karl Drotning, Brooks Lillehei, Jenna
Majorowicz, Jason Swenson, and Jeff Witte
Members Absent: Scott Einck and Ex-Officio Mike Lamm
StaffPresent: Planning Director Daryl Morey and Daniel Licht, TPC
OthersPresent: City Councilmember Joshua Lee
Corridor MixedUse (CMU) BusTourDiscussion
Mr. Licht outlined his August 19, 2019 memorandum summarizing the July 23, 2019
CMU bus tour that included staff, the Planning Commission, and the City Council. The
bus tour included stops atTown Center in Eden Prairie, the Gravel Mining Area/Arbor
Lakes in MapleGrove, and Park Commons inSt. Louis Park. The Planning
Commission made the following comments:
Liked the centrally located City park, which included recreational activities for all
seasons, in MapleGrove’sGravel Mining Area/Arbor Lakes development.
Town Center in Eden Prairie seemed somewhat disconnected, more car centric,
and less pedestrian friendly. Additional pedestrian connections between uses is
needed.
The Park Commons area in St. Louis Park was too high density and the buildings
were too tall for Lakeville’svision; however, the community park facilities
including the pool, ice arena, and adjacent park were nice features.
Noted that major cooperate office projects providing significant employment
opportunities anchored each ofthe three cities visited on the bus tour.
Commercial development along the Cedar Avenue corridor is likely to be less
regional in nature as the area is not adjacent to interstate freeways like in Eden
Prairie and MapleGrove.
All three cities on the bus tour have transit facilities already in place. Concern
was raised over adding additional traffic in the Cedar Avenue corridor with
increased residential density and land use intensity without additional transit
facilities.
The Planning Commission liked the variation in residential dwelling types within
the Gravel Mining Area/Arbor Lakes area ofMapleGrove.
Pedestrian, bike and vehicle connections will be important for Lakeville’s CMU
District. The ability to live, work and play inthe same area is also important.
PlanningCommissionWorkSessionMinutes – September5, 2019 Page2
The CMU districts need to be connected to the larger Lakeville community in
terms of site design and architectural character.
A public open space requirement should be considered for incorporation into the
CMU District with the next update to the Parks, Trails, and Open Space Plan
and/or provision made to include minimum usable open space requirements with
each development.
CMU land uses developed outside of the Cedar Avenue corridor require a
separate set of development standards that will address consistency with
adjacent existing and planned residential and commercial development.
The Planning Commission would like to be provided with the City’sCouncil’scommentsrdontheCMUbustouraftertheSeptember23worksession.
The work session adjourned at 7:25 p.m.
Respectfully submitted,
Daryl Morey, Planning Director
CITY OF LAKEVILLE
CITY COUNCIL WORK SESSION MINUTES
September 23, 2019
1.Mayor Anderson called the meeting to order at 6:00 p.m. in the Marion Conference Room.
Members present: Mayor Anderson, Council Members Hellier, Lee, Volk, and
Wheeler
Members absent: None
Staff present: Justin Miller, City Administrator; Allyn Kuennen, Assistant City Administrator;
Paul Oehme, Public Works Director; Neil Normandin, Public Works & Facilities Coordinator;
Mac Cafferty, Environmental Resources Manager; Daryl Morey, Planning Director; Jerilyn
Erickson, Finance Director; Tamara Wallace, Deputy Clerk
2. Citizen Comments
There were no citizen comments regarding non-agenda items.
3. Environmental Initiative Update:
Staff, alongside Steve McComas with Blue Water Science, provided an overview of the
environmental improvement efforts throughout the City. The presentation included updates on
various 2019 projects, water efficiency initiatives, Dakota County’s organic drop-off site,
inspection and maintenance activities, education/ volunteer efforts, status of the Green Step
Cities initiative, solar gardens, and a look ahead at some proposed 2020 projects. Mr. McComas
also reviewed the status of lakes within the City and provided some long-term management
efforts to continue to improve lake health.
4. CMU Tour Recap
Dan Licht, with The Planning Company, gave an update on a recent bus tour the City Council,
Planning Commission, and City staff attended. The tour included stops in Eden Prairie, Maple
Grove, and St. Louis Park, with the purpose of examining development standards to see how the
City would implement the Corridor Mixed Use districts as outlined in the 2040 Comprehensive
Plan. The next step would be to formulate an outline of these zoning districts to look at
guidelines that can be used for development applications next year.
The Council reviewed the feedback and expressed the desire to still maintain a distinction
between the allowable standards on Cedar Avenue versus I-35, and the need to differentiate
within the zoning ordinance how close to transportation the land use district would be. The
Council was comfortable with the recommendations and direction of the Planning Commission.
City Lakeville Burnsville Eden Prairie Maple Grove St. Louis Park
Area Existing HDR Heart of the City Town Center Arbor Lakes/
Gravel Mining Area
Park Commons
Zoning RH-1 RH-2 PUD HOC-1 District
Design Guidelines
Town Center District
Design Guidelines
PUD
Design Guidelines
MIX
R-C District
Allowed Uses Two family
Row townhouse
Back-to-back townhouse
Multiple Family
Senior housing
Park
Two family
Row townhouse
Back-to-back townhouse
Multiple Family
Senior housing
Park
Two family
Row townhouse
Back-to-back townhouse
Multiple Family
Retail
Service
Office
Self-storage
Single family
Row townhouse
Back-to-back townhouse
Multiple Family
Senior housing
Mixed use
Neighborhood commercial
Office
Sit down restaurant
Counter serve restaurant
Service
Hotel
Motor fuel
Civic
Park
Transit facilities
Row townhouse
Back-to-back townhouse
Multiple Family
Senior housing
Mixed use
Neighborhood commercial
Regional commercial
Office
Sit down restaurant
Counter serve restaurant
Service
Hotel
Civic
Park
Transit facilities
Single family
Detached townhouse
Row townhouse
Back-to-back townhouse
Multiple Family
Senior housing
Mixed use
Neighborhood commercial
Regional commercial
Office
Sit down restaurant
Counter serve restaurant
Convenience food
Accessory motor fuel
Service
Hotel
Civic
Park
Transit facilities
Multiple Family
Senior housing
Mixed use
Neighborhood commercial
Regional commercial
Office
Sit down restaurant
Counter serve restaurant
Convenience food
Accessory motor fuel
Service
Hotel
Civic
Park
Density TH: 8.7du/ac.
MF: 17du/ac.
Senior: 29du/ac.
TH: 8.7du/ac.
MF: 17du/ac.
Senior: 29du/ac.
26du/ac. 20-60du/ac. HDR: 40-75du/ac.
Mixed use: 40-75du/ac.
TOD: 40-70du/ac.
Low: 3-5du/ac
Medium: 7-9du/ac
High: 24-33du/ac or higher
HDR: 30-75du/ac.
Mix: 20-75du/ac.
TOD: 50-125du/ac.
Max. Building
Height
3 stories 4 stories 4 stories Not limited Not limited Not limited 6 stories
Setbacks Front 50ft. major roadways
30ft. local streets
50ft. major roadways
30ft. local streets
30ft. Build-to ROW
0ft. min.
20ft. max
0ft. 0ft.
Side 30ft. 30ft. 30ft. 0ft. 20ft. 0ft. 0ft.
Rear 30ft. 30ft. 30ft. 5ft. 20ft. 0ft. 0ft.
Landscape/usable
open space
-- -- -- 10% of lot area 5% of lot area 12% of lot area
Parking Ratio 2.5 stalls/du. 2.5 stalls/du 2.0 stalls/du. 1.5 stalls/du 1.0 stalls/du. min
1.0 stall/bedroom max
Min. 1 stall underground
2.0 stalls/du
Min. 1 stall/du underground
1 stall/bedroom
80% of parking within
structures (MIX District)