Loading...
HomeMy WebLinkAboutSURVEYSRECEIVED By Lucas Ritchie at 2:31 pm, Aug 15, 2022 CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: LA189728 Legal Description: Lot 6 Block 3 Subdivision: SUMMERLYN 9TH ADDITION Address: 19269 Huntington Avenue We -F hereby certify that on 3rd day of August , 2022 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: �i9P .ter .1 Hawkinson 9 Si nature: / c �( Date: August 5, 2022 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 11x17 1 /\ Ill X 1045 9 1042 8 / (1041.9) ,,-oaa4 ---> X 1043 9 0 1043 4 1042.2 1040 4 / N 172787 51 E:518796.21 1041 9 a) 0 0 c X 10 x 1041 1 1038 8 / / N 172677 61 E:518794.4: // 1038.0 - X 10409 op 1 M I X 1041 2 to 0 1043.2 X 1043 2 6 X 10431 1043 1 85.6 x 1046 2 N89°49'09"W Sodded X 1047.1 1048.3 170.00 Existing House 1057.0 % 1055 1 tob X 1052. Yob@! 19/9, 1053 3 1051.2 O 1045.6 x `i U5 i k lo5o x 1050.0 0 1043.8 1/l.'. 7 1049.1 �:. 1043.0 1044.5 - . 1 0 1048.7 1049 0 -d 1048.2 x 1043.6 X 1043 7 X 1043 7 1044.0, 1044.1 x 03 N. 1043 9 O I \\ ‘-'54 039.6 \ X 1040.4 1/ I 0 Construction Notes: 1. Install rock construction entrance 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1 0% 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional, Wall installed if the grade exceeds 3 1. Wall will not be installed if the grade is 3:1 or less. General Notes: 1. Grading plan by Pioneer last dated 10-24-19 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans 4. No specific soils investigation has been performed on this lot by the surveyor The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. .4 -7 1040.3 X 1041.7 1041 0 11 X 1041 9 N89°49'09"W Graded • Denotes iron pipe Denotes service • Denotes television box ▪ Denotes electric box Q Denotes telephone box X 000 00 Denotes existing elevation ( 000 00 ) Denotes proposed elevation Denotes drainage flow direction • Denotes spike Denotes proposed retaining wall 1048.1 x r 1044 51 1048 3 1043.9 104411 1 10441044.8 ;)11 1 1044.5 46.1 1048.E 1049.W 1048 8 24.5 1o48.6 \ 1049.0 1042 11 E...■ X 1042.4 designed and built by others. c0 1048.8 1049 1 1049.2 gf 1049 2 2.0 N, 1048 8, T 0 0 1049.1 10488 10486 78 20 -5049.1 1044 Existing House 170.00 REVISED Lowest floor elevation per grading plan : 941.2 House elevations Lowest Footing Elevation Top 0f Foundation Elev Garage Lip Elev. © Door T.O.F. Elevation (Proposed) / As -built : (1041.5) / 1041.5 : (1049.5) / 1049.5 : (1049.2) / 1049.2 © Lookout:(1044.7) / 1044.7 `o a 1049.0 2.0 m 58 to 8E co t0 10477 1048.9 10 1048. X Q) N N 1 1046.9 \ o--- 30.5 ----- • 1048.8 1049.0 1p48 7 X 1048.6 �48., 1047 9 / _=ac_x_104 0 X 1043 3 1044 4 tob /"\1043 5 N•172702.18 E•518964.94 1045.3 I30 104/3.4 II 1049 0 ; 1048.5 1047.8 , 0449 O I uri : 104E 3 ( 1041.3 I Z3 104 .1 O a- 10 1045.1 1045.5 X 1044.0 .: 104219 x 1044.6 -u 1042 5 1042.2 10-4 11 v V v u11.7)42 6 i 0421.2- N OIX 1042 2 1041.7 30 8/3/22 GRADING AS -BUILT Lot area = 14450 SF House area = 2386 SF Porch area = 227 SF Sidewalk area = 64 SF Driveway area = 993 SF Total Impervious Area = 3670 SF Impervious Coverage = 25.4% We hereby certify to Lennar Corporation that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 02/11/21. BY Signed: //PiArleer Eggineering, P.A. Peter J. HaLI ( ibn, (rrotegonal Land surveyor Minnesota License No 42299 email-phawkinson@pioneereng.com 0' Y v Y v v Y v 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Lot 7, Block 3 Elevation =1040 86 Revisions 1 ) 02-16-21 House Stake 2 ) 05-06-21 Re -stake house 3 )05-21-21 Foundation As -built 4 ) 06-03-22 Grading As -built U 3 A to rn r� 00 at -0 o c to o w N • 22 at U C) 1r