HomeMy WebLinkAboutLA176160 - 17317 Eastwood Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Secure door closed until deck is
constructed with a separate permit.
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2015
MN Bldg
Code
12/11/2019dmathews
5
Smoke
-Min. 15" clearance to any
obstruction from center ofW.C., 24" in front(typ).
CO
5
PFHPFH
PFH PFH
5
5
Builders Associaton of Minnesota version 101014
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Certificate Posted
12/9/2019
Mailing Address of the Dwelling or Dwelling Unit City
17317 Eastwood Ave Lakeville
Name of Residential Contractor MN License Number
Silver Tree Plumbing and Heating MB005441
THERMAL ENVELOPE RADON CONTROL SYSTEM
Insulation Location
To
t
a
l
R-
V
a
l
u
e
of
al
l
Ty
p
e
s
of
In
s
u
l
a
t
i
o
n
Type: Check All That Apply X Passive (No Fan)
No
n
or
No
t
Ap
p
l
i
c
a
b
l
e
Fi
b
e
r
g
l
a
s
s
,
Bl
o
w
n
Fi
b
e
r
g
l
a
s
s
,
Ba
t
t
s
Fo
a
m
,
Clo
s
e
d
Ce
l
l
Fo
a
m
Op
e
n
Ce
l
l
Min
e
r
a
l
Fi
b
e
r
b
o
a
r
d
Rig
i
d
,
Ex
t
r
u
d
e
d
Po
l
y
s
t
y
r
e
n
e
Rig
i
d
,
Is
o
c
y
n
u
r
a
t
e
Active (With fan and monometer or other
system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
Below Entire Slab X
Foundation Wall R-10 X Interior R10 Exterior
Perimeter of Slab on Grade X
Rim Joist (1st Floor)R-20 X Interior
Rim Joist (2nd Floor+)X
Wall R-20 X
Ceiling, flat R-49 X
Ceiling, vaulted R-49 X
Bay Windows or cantilevered areas R-30 X
Floors over unconditioned area R-30 X
Describe other insulated areas
Building envelope air tightness:Duct system air tightness:
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.32 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.32 R8 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water
Heater Cooling System X Not required per mech. code
Fuel Type Nat Gas Nat Gas Electric Passive
Manufacturer Bryant Rheem Bryant Powered
Model 912SD36060E14 43VP50E2 BA13030 Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:60,000 Capacity in
Gallons:50 Output in
Tons:2.5 Ton Other, describe:
Efficiency
AFUE or
HSPF%
92%0.72 SEER
/EER 13 Location of duct or system:
Residential Load Calculation
Heating Loss Heating Gain Cooling Load
44,076 24,004 26,243 Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms:Low: High:Other, describe:
X Energy Recover Ventilator (ERV) Capacity in cfms:Low: 40%= 70 cfm High:80%= 141 CFM Location of duct or system:
Balanced Ventilation capacity in cfms:80% = 141 CFM Mech Room
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms:70 CFM 6 " round duct OR
Total ventilation (intermittent + continuous) rate in cfms:141 CFM " metal duct
Site address Date 11/15/2019
Contractor Silver Tree Plumbing & Heating, LLC By Jake Ryan
Section A
Square feet (Conditioned area inc. 2810 TOTAL VENTILATION 131
basement – finished or unfinished)CONTINUOUS VENTILATION 66
Number of bedrooms 4
# of BEDROOMS 1 2 3 4 5 6
Total/ Total/ Total/ Total/ Total/ Total/
continuous continuous continuous continuous continuous continuous
1000-1500 60/40 75/40 90/45 105/53 120/60 135/68
1501-2000 70/40 85/43 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110/55 125/63 140/70 155/78
2501-3000 90/45 105/53 120/60 135/68 150/75 165/83
3001-3500 100/50 115/58 130/65 145/73 160/80 175/88
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 165/83 180/90 195/98
4501-5000 130/65 145/73 160/80 175/88 190/95 205/103
5001-5500 140/70 155/78 170/85 185/93 200/100 215/108
5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113
Equation R403.5.2 2015 Mn Energy Code
(0.02 x conditioned space) + (15 X (# of bedrooms + 1))= TOTAL VENTILATION RATE
Sq Ft 2810 0.02 56.2
Bedrooms 4 15 60
Plus 1 bedroom 15
TOTAL VENT 131.20 CFM
Section B
Low cfm: High cfm:
70 141
Section D
Control set at 40% 70 CFM
80%/HIGH 141 CFM
☒Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery Ventilator) – cfm of unit in low must not exceed continuous ventilation rating by more than
100%.
Ventilation Controls
(Describe operation and control of the continuous ventilation)
(BALANCED)
Table R403.5.2 2015 Minnesota Energy Code
Total and Continuous Ventilation Rates (in cfm)
Conditioned space
(in sq. ft.)
2015 Mechanical & Energy Code – Ventilation, Makeup, and Combustion Air Calculations
Ventilation Method
17317 Eastwood Ave, Lakeville
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code)
Page 1 of 5
Builders Associaton of Minnesota version 101014
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Certificate Posted
12/9/2019
Mailing Address of the Dwelling or Dwelling Unit City
17317 Eastwood Ave Lakeville
Name of Residential Contractor MN License Number
Silver Tree Plumbing and Heating MB005441
THERMAL ENVELOPE RADON CONTROL SYSTEM
Insulation Location
To
t
a
l
R-
V
a
l
u
e
of
al
l
Ty
p
e
s
of
In
s
u
l
a
t
i
o
n
Type: Check All That Apply X Passive (No Fan)
No
n
or
No
t
Ap
p
l
i
c
a
b
l
e
Fi
b
e
r
g
l
a
s
s
,
Bl
o
w
n
Fi
b
e
r
g
l
a
s
s
,
Ba
t
t
s
Fo
a
m
,
Clo
s
e
d
Ce
l
l
Fo
a
m
Op
e
n
Ce
l
l
Min
e
r
a
l
Fi
b
e
r
b
o
a
r
d
Rig
i
d
,
Ex
t
r
u
d
e
d
Po
l
y
s
t
y
r
e
n
e
Rig
i
d
,
Is
o
c
y
n
u
r
a
t
e
Active (With fan and monometer or other
system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
Below Entire Slab X
Foundation Wall R-10 X Interior R10 Exterior
Perimeter of Slab on Grade X
Rim Joist (1st Floor)R-20 X Interior
Rim Joist (2nd Floor+)X
Wall R-20 X
Ceiling, flat R-49 X
Ceiling, vaulted R-49 X
Bay Windows or cantilevered areas R-30 X
Floors over unconditioned area R-30 X
Describe other insulated areas
Building envelope air tightness:Duct system air tightness:
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.32 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.32 R8 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water
Heater Cooling System X Not required per mech. code
Fuel Type Nat Gas Nat Gas Electric Passive
Manufacturer Bryant Rheem Bryant Powered
Model 912SD36060E14 43VP50E2 BA13030 Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:60,000 Capacity in
Gallons:50 Output in
Tons:2.5 Ton Other, describe:
Efficiency
AFUE or
HSPF%
92%0.72 SEER
/EER 13 Location of duct or system:
Residential Load Calculation
Heating Loss Heating Gain Cooling Load
44,076 24,004 26,243 Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms:Low: High:Other, describe:
X Energy Recover Ventilator (ERV) Capacity in cfms:Low: 40%= 70 cfm High:80%= 141 CFM Location of duct or system:
Balanced Ventilation capacity in cfms:80% = 141 CFM Mech Room
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms:70 CFM 6 " round duct OR
Total ventilation (intermittent + continuous) rate in cfms:141 CFM " metal duct
12/05/19 X