HomeMy WebLinkAboutLA176159 16415 Klamath Tr Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode10/25/2019dmathews
3.53.534" CS-PF34" CS-PFUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
COVerify loads withgirder truss specs,may requireremoval of topplates at bearingdue to crushing.24" CS-PF24" CS-PF24" CS-PF24" CS-PF24" CS-PF24" CS-PF8821" CS-PF21" CS-PF21" CS-PF21" CS-PF24" CS-PF24" CS-PF24" CS-PF24" CS-PF-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
BRACED WALLS
16415 KLAMATH TRAIL
FIG. R602.10.1.3 LAKEVILLE, MN
WIND BRACING 9/11/2019
115 MPH
DETACHED
MAX. SPA. = 60 FEET
REQUIRED BRACING LENGTH TABLE R602.10.3(1)
ADJUSTMENT FACTORS TABLE R602.10.3(2)
EXPOSURE
1 STORY
CONDITION B
ADJ FACTOR 1.00
ROOF EAVE TO RIDGE HT
HT = 14'
ADJ FACTOR 1.30
WALL HEIGHT ADJUSTMENT
HT. 1ST = 10'
ADJ FACTOR = 1.00
NUMBER OF BRACED WALL LINES
2 1.00
3 1.30
4 1.45
B. W.
LINE
SPA. MIN.
LENGTH
EXPOSURE EAVE TO
RIDGE HT.
WALL HT. NO. OF
BWL
TOTAL
ADJ.
MIN.
REQ'D
PROVIDED
GA 30.0 5.5 1.00 1.30 1.00 1.00 1.30 7.2 24.0
B 14.0 2.6 1.00 1.30 1.00 1.45 1.89 4.9 24.0
C 20.0 3.5 1.00 1.30 1.00 1.45 1.89 6.6 20.0
GC 30.0 5.5 1.00 1.30 1.00 1.00 1.30 7.2 12.0
D 20.0 3.5 1.00 1.30 1.00 1.45 1.89 6.6 20.0
E 10.0 2.0 1.00 1.30 1.00 1.45 1.89 3.8 8.0
BF LINE D X 1.15 =7.6 12.0
BG LINE E X 1.15 =4.3 20.0
1 56.0 9.9 1.00 1.30 1.00 1.30 1.69 16.7 20.0
2 56.0 9.9 1.00 1.30 1.00 1.30 1.69 16.7 20.0
G3 44.0 7.8 1.00 1.30 1.00 1.00 1.30 10.1 12.0
4 28.0 5.1 1.00 1.30 1.00 1.30 1.69 8.6 12.0
G5 44.0 7.8 1.00 1.30 1.00 1.00 1.30 10.1 12.0
ADJUSTMENT FACTORS
Hebert Homes
HVAC Load Calculations
for
Strohbehn
16415 Klamath Trail
Lakeville,mn
Prepared By:
Randy Andrews
Lofgren Heating
5708 Upper 147th Street West
Apple Vallley, MN 55124
Tuesday, August 27, 2019
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 2
Project Report
General Project Information
Project Title:Hebert Homes
Project Date:Tuesday, August 27, 2019
Client Name:Strohbehn
Client Address:16415 Klamath Trail
Client City:Lakeville,mn
Company Name:Lofgren Heating
Company Representative:Randy Andrews
Company Address:5708 Upper 147th Street West
Company City:Apple Vallley, MN 55124
Company E-Mail Address:rrandrews@lofgrenheating-ac.com
Design Data
Reference City:Minneapolis, Minnesota
Building Orientation:Front door faces Southeast
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Elevation Sensible Adj. Factor:1.000
Elevation Total Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -15.33 80%n/a 72 n/a
Summer:88 72 47%50%75 29
Check Figures
Total Building Supply CFM:1,427 CFM Per Square ft.:0.252
Square ft. of Room Area:5,672 Square ft. Per Ton:1,658
Volume (ft³) of Cond. Space:51,048
Building Loads
Total Heating Required Including Ventilation Air:63,495 Btuh 63.495 MBH
Total Sensible Gain:30,790 Btuh 84 %
Total Latent Gain:5,660 Btuh 16 %
Total Cooling Required Including Ventilation Air:36,450 Btuh 3.04 Tons (Based On Sensible + Latent)
3.42 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 3
Load Preview Report
Scope
Has
AED
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 3.04 1,867 5,672 30,790 5,660 36,450 63,495 1,227 1,427 1,427
System 1 No 3.04 1,867 5,672 30,790 5,660 36,450 63,495 1,227 1,427 1,427 24x10
Ventilation 340 1,352 1,692 4,550
Zone 1 5,672 30,451 4,308 34,759 58,945 1,227 1,427 1,427 24x10
1-Upper Level 2,836 23,383 3,068 26,451 37,274 776 1,095 1,095 13--6
2-Lower Level 2,836 7,068 1,240 8,308 21,671 451 331 331 4--6
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 4
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
540 15,033 0 14,306 14,306
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
2550 14,421 0 2,205 2,205
15B0-15sf-10: Wall-Basement, , R-15 board insulation to
floor, no interior finish, 10' floor depth
1620 5,920 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
2836 4,935 0 2,723 2,723
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1996 4,341 0 0 0
Subtotals for structure:45,928 0 19,586 19,586
People:7 1,400 1,610 3,010
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 140, Summer CFM: 73 13,017 1,408 1,011 2,419
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
AED Excursion:0 0 2,244 2,244
Total Building Load Totals:63,495 5,660 30,790 36,450
Check Figures
Total Building Supply CFM:1,427 CFM Per Square ft.:0.252
Square ft. of Room Area:5,672 Square ft. Per Ton:1,658
Volume (ft³) of Cond. Space:51,048
Building Loads
Total Heating Required Including Ventilation Air:63,495 Btuh 63.495 MBH
Total Sensible Gain:30,790 Btuh 84 %
Total Latent Gain:5,660 Btuh 16 %
Total Cooling Required Including Ventilation Air:36,450 Btuh 3.04 Tons (Based On Sensible + Latent)
3.42 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 5
Building Pie Chart
Building
Loss
63,495
Btuh
Floor 7%
Roof 8%
Wall 32%
Glass 24%
Door 2%
Infiltration 21%
Ventilation 7%
Building
Gain
36,450
Btuh
Roof 7%
Wall 6%
Glass 39%
Door 1%People 8%
Equipment 21%
Infiltration 7%
Ventilation 5%
AED Excursion 6%
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 6
System 1 Whole House Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
540 15,033 0 14,306 14,306
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
2550 14,421 0 2,205 2,205
15B0-15sf-10: Wall-Basement, , R-15 board insulation to
floor, no interior finish, 10' floor depth
1620 5,920 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
2836 4,935 0 2,723 2,723
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1996 4,341 0 0 0
Subtotals for structure:45,928 0 19,586 19,586
People:7 1,400 1,610 3,010
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 140, Summer CFM: 73 13,017 1,408 1,011 2,419
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
AED Excursion:0 0 2,244 2,244
System 1 Whole House Load Totals:63,495 5,660 30,790 36,450
Check Figures
Supply CFM:1,427 CFM Per Square ft.:0.252
Square ft. of Room Area:5,672 Square ft. Per Ton:1,658
Volume (ft³) of Cond. Space:51,048
System Loads
Total Heating Required Including Ventilation Air:63,495 Btuh 63.495 MBH
Total Sensible Gain:30,790 Btuh 84 %
Total Latent Gain:5,660 Btuh 16 %
Total Cooling Required Including Ventilation Air:36,450 Btuh 3.04 Tons (Based On Sensible + Latent)
3.42 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 7
Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:2,836.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:2,836.0 sq.ft.Supply Air:1,095 CFM
Ceiling Height:9.0 ft.Supply Air Changes:2.6 AC/hr
Volume:25,524.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:13 Actual Winter Vent.:89 CFM
Runout Air:84 CFM Percent of Supply.:8 %
Runout Duct Size:6 in.Actual Summer Vent.:54 CFM
Runout Air Velocity:429 ft./min.Percent of Supply:5 %
Runout Air Velocity:429 ft./min.Actual Winter Infil.:106 CFM
Actual Loss:0.115 in.wg./100 ft.Actual Summer Infil.:55 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
SW-Wall-12F-0sw 48 X 9 345 0.065 5.7 1,951 0.9 0 298
NE-Wall-12F-0sw 48 X 9 407 0.065 5.7 2,302 0.9 0 352
NW-Wall-12F-0sw 84 X 9 607 0.065 5.7 3,433 0.9 0 525
SE-Wall-12F-0sw 84 X 9 615 0.065 5.7 3,478 0.9 0 532
SE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
SE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
SW-Gls-4A-1a-o shgc-0.33 0%S 87 0.320 27.8 2,422 31.0 0 2,695
NE-Gls-4A-1a-o shgc-0.33 0%S 25 0.320 27.8 696 24.1 0 603
NW-Gls-4A-1a-o shgc-0.33 0%S 149 0.320 27.8 4,148 24.1 0 3,596
SE-Gls-4A-1a-o shgc-0.33 0%S 99 0.320 27.8 2,756 31.0 0 3,067
UP-Ceil-16B-50 2836 X 1 2836 0.020 1.7 4,935 1.0 0 2,723
Subtotals for Structure:27,399 0 14,743
Infil.: Win.: 106.4, Sum.: 55.3 2,376 4.156 9,875 0.323 1,068 767
AED Excursion:1,723
People: 200 lat/per, 230 sen/per:5 1,000 1,150
Equipment:1,000 5,000
Room Totals:37,274 3,068 23,383
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 8
Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:2,836.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:2,836.0 sq.ft.Supply Air:331 CFM
Ceiling Height:9.0 ft.Supply Air Changes:0.8 AC/hr
Volume:25,524.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:4 Actual Winter Vent.:51 CFM
Runout Air:83 CFM Percent of Supply.:16 %
Runout Duct Size:6 in.Actual Summer Vent.:16 CFM
Runout Air Velocity:422 ft./min.Percent of Supply:5 %
Runout Air Velocity:422 ft./min.Actual Winter Infil.:34 CFM
Actual Loss:0.111 in.wg./100 ft.Actual Summer Infil.:18 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
NW-Wall-12F-0sw 84 X 9 576 0.065 5.7 3,257 0.9 0 498
SE-Wall-15B0-15sf-10 84 X 9 756 0.042 3.7 2,762 0.0 0 0
SW-Wall-15B0-15sf-10 48 X 9 432 0.042 3.7 1,579 0.0 0 0
NE-Wall-15B0-15sf-10 48 X 9 432 0.042 3.7 1,579 0.0 0 0
NW-Gls-4A-1a-o shgc-0.33 0%S 180 0.320 27.8 5,011 24.1 0 4,345
Floor-21A-24 1 X 1996 1996 0.025 2.2 4,341 0.0 0 0
Subtotals for Structure:18,529 0 4,843
Infil.: Win.: 33.8, Sum.: 17.6 756 4.156 3,142 0.323 340 244
AED Excursion:521
People: 200 lat/per, 230 sen/per:2 400 460
Equipment:500 1,000
Room Totals:21,671 1,240 7,068
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 9
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Upper Level 2,836 37,274 776 13-6 429 23,383 3,068 1,095 1,095
2 Lower Level 2,836 21,671 451 4-6 422 7,068 1,240 331 331
Ventilation 4,550 340 1,352
System 1 total 5,672 63,495 1,227 30,790 5,660 1,427 1,427
System 1 Main Trunk Size:24x10 in.
Velocity:856 ft./min
Loss per 100 ft.:0.102 in.wg
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:3.04 84% / 16%30,790 5,660 36,450
Recommended:3.42 75% / 25%30,790 10,263 41,054
Actual:1.00 77% / 23%9,240 2,760 12,000
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:QC-F38-E78-G QC-C12
Indoor Model:S12
Brand:Quikcool FE Series Quikcool AS Series
Description:Hi Efficiency Furnace Standard Efficiency Air Condit
Efficiency:78.3 AFUE 12.4 SEER
Sound:8.1 bels
Capacity:38,000 Btuh 12,000 Btuh
Sensible Capacity:n/a 9,240 Btuh
Latent Capacity:n/a 2,760 Btuh
C:\ ...\16415 KLAMATH RAMBLER LAKEVILLE 08272019.rhv Tuesday, August 27, 2019, 10:15 AM
Passive (No Fan)
Active (With fan and monitoring
device )
Location (or future location) of Fan:
Other Please Describe Here
Not applicable, all ducts located in conditioned space
Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
Passive
Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
" round duct OR
" metal duct
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
New Construction Energy Code Compliance Certificate
Name of Residential Contractor MN License Number
City Mailing Address of the Dwelling or Dwelling Unit
Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
Combustion Air Select a Type
Location of duct or system:
Rim Joist (2nd Floor+)
Building envelope air tightness:
Below Entire Slab
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Total R-Value of all Types of InsulationType: Check All That Apply
Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas
Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall
Output
in Tons:
Appliances Cooling System
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Make-up Air Select a Type
Domestic Water
Heater
Model
Heating System
Rim Joist (1st Floor)
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness:
Rating or Size
Efficiency
Heating Gain Cooling Load
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Residential Load
Calculation
SEER
/EER
Capacity continuous ventilation rate in cfms:
Heating Loss
Manufacturer
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Date Cert. Posted
R-value
MECHANICAL SYSTEMS
Builders Associaton of Minnesota version 101014
x
x
4"
225
113
225