HomeMy WebLinkAboutLA176332 - 18007 Gresford Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
S S 5'-8"
4'
-
5
1
/
2
"
2
'
-
1
1
1
/
2
"
6
'
3
4
'
40'10'-10" 5'-10" 23'-4"
6'
-
6
"
54
'
25
'
-
5
1
/
2
"
28
'
-
6
1
/
2
"
12
'
-
2
"
54
'
48
'
-
4
"
Or
f
i
e
l
d
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
35
0
7
W
5
0
t
h
S
T
Mi
n
n
e
a
p
o
l
i
s
,
M
N
5
5
4
1
0
SHEET:
SCALE:
1/4"=1'0"
Fo
u
n
d
a
t
i
o
n
P
l
a
n
DATE:
**
*
*
(
2
)
2
x
1
0
H
D
R
U
N
O
*
*
*
*
*
He
a
d
e
r
s
p
a
n
s
u
p
t
o
3
'
1
1
"
=
1
t
r
i
m
m
e
r
s
,
4
'
0
"
a
n
d
b
i
g
g
e
r
=
2
t
r
i
m
m
e
r
s
U
N
O
PR
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
:
SH
E
E
T
T
I
T
L
E
:
Sk
e
t
c
h
#
6
Sl
a
b
o
n
G
r
a
d
e
o
p
t
i
o
n
A-
1
12/16/2019
D
W
W0
2
W0
2
W
0
2
W0
3
W0
3
W
0
3
W0
4
W0
4
W
0
4
W0
1
W0
1
W
0
1
SD
SD
CO
/
S
D
CO
/
S
D
5
'
-
9
"
24'
6
'
3
4
'
3
4
'
8
'
-
7
7
/
8
"
1
9
'
-
4
1
/
8
"
6
'
6'
-
6
"
54
'
25
'
-
5
1
/
2
"
7'
3'
-
9
"
5'
-
3
1
/
2
"
12
'
-
6
"
40'
11
'
-
6
"
54
'
34
'
-
8
1
/
4
"
2'
-
4
1
/
2
"
11
'
-
1
1
1
/
4
"
19
'
8'
7'
-
8
1
/
4
"
4'
-
5
3
/
4
"
5'
-
1
0
"
1'
4'
2
'
-
1
1
1
/
2
"
4'
1
6
'
9
'
-
8
"
3'
-
9
"
8
'
-
4
"
6
'
-
1
1
"
3
'
-
6
"
4'
4'
3
'
-
6
"
25
'
-
5
1
/
2
"
4'
5
'
!
"
(
2
)
1
1
7
/
8
"
L
V
L
#
$
%
&
%
'
(
(
'
(
(
(
)
P
o
r
t
a
l
f
r
a
m
e
t
h
i
s
w
a
l
l
)
*
+
+
,- (3)2x10
)
+
.
(
2
)
9
1
/
2
"
L
V
L
(
2
)
9
1
/
2
"
L
V
L
/
*
+
(
2
)
2
x
1
0
(
2
)
2
x
1
0
WI
N
D
O
W
S
C
H
E
D
U
L
E
NU
M
B
E
R
L
A
B
E
L
Q
T
Y
F
L
O
O
R
S
I
Z
E
W
I
D
T
H
H
E
I
G
H
T
D
E
S
C
R
I
P
T
I
O
N
W0
1
6
2
5
0
M
U
1
1
6
2
5
0
7
4
"
6
0
"
M
U
L
L
E
D
U
N
I
T
W0
2
2
8
3
0
S
C
1
1
2
8
3
0
S
C
3
2
"
3
6
"
S
N
G
L
C
A
S
E
M
E
N
T
-
H
R
W0
3
5
0
5
0
M
U
1
1
5
0
5
0
6
0
"
6
0
"
M
U
L
L
E
D
U
N
I
T
W0
4
9
4
5
0
M
U
1
1
9
4
5
0
1
1
2
"
6
0
"
M
U
L
L
E
D
U
N
I
T
W0
6
4
0
2
0
F
X
1
2
4
0
2
0
F
X
4
8
"
2
4
"
F
I
X
E
D
G
L
A
S
S
Or
f
i
e
l
d
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
35
0
7
W
5
0
t
h
S
T
Mi
n
n
e
a
p
o
l
i
s
,
M
N
5
5
4
1
0
SHEET:
SCALE:
1/4"=1'0"
Ma
i
n
F
l
o
o
r
P
l
a
n
DATE:
PR
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
:
SH
E
E
T
T
I
T
L
E
:
Sk
e
t
c
h
#
6
Sl
a
b
o
n
G
r
a
d
e
o
p
t
i
o
n
A-
2
**
*
*
(
2
)
2
x
1
0
H
D
R
U
N
O
*
*
*
*
*
He
a
d
e
r
s
p
a
n
s
u
p
t
o
3
'
1
1
"
=
1
t
r
i
m
m
e
r
s
,
4
'
0
"
a
n
d
b
i
g
g
e
r
=
2
t
r
i
m
m
e
r
s
U
N
O
12/16/2019
Or
f
i
e
l
d
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
35
0
7
W
5
0
t
h
S
T
Mi
n
n
e
a
p
o
l
i
s
,
M
N
5
5
4
1
0
SHEET:
SCALE:
DATE:
El
e
v
a
t
i
o
n
s
1/4"=1'0"
PR
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
:
SH
E
E
T
T
I
T
L
E
:
Sk
e
t
c
h
#
6
Sl
a
b
o
n
G
r
a
d
e
o
p
t
i
o
n
A-
3
Wi
n
d
o
w
m
a
x
i
m
u
m
U
f
a
c
t
o
r
:
.
3
2
Wi
n
d
o
w
f
a
l
l
p
r
o
t
e
c
t
i
o
n
i
s
r
e
q
u
i
e
d
w
h
e
r
e
t
h
e
l
o
w
e
s
t
pa
r
t
o
f
t
h
e
o
p
e
n
i
n
g
i
s
lo
c
a
t
e
d
m
o
r
e
t
h
a
n
7
2
"
a
b
o
v
e
f
i
n
i
s
h
e
d
f
l
o
o
r
.
O
p
e
r
a
b
l
e
s
e
c
t
i
o
n
s
o
f
wi
n
d
o
w
s
s
h
a
l
l
n
o
t
p
e
r
m
i
t
o
p
e
n
i
n
g
s
t
h
a
t
a
l
l
o
w
p
a
s
s
a
g
e
o
f
a
4
"
d
i
a
m
e
t
e
r
sp
h
e
r
e
w
h
e
r
e
s
u
c
h
o
p
e
n
i
n
g
s
a
r
e
l
o
c
a
t
e
d
w
i
t
h
i
n
g
3
6
"
of
t
h
e
f
i
n
i
s
h
e
d
f
l
o
o
r
.
9
i
n
1
2
6
i
n
1
2
9 i n 1 2
12/16/2019
-
*
0
/
(
1
-+
&
.
'
2
3
-
4
5
0
1
/
0 -
.
'
(
(
2
-
(
'
0
(
(
6
$
1
-
&
7
8
/
-
+
1
(
9
(
)
$
7
*
"
$
:
*
1
(
;
*
$
0
+
-
-
#
"
2
<
=
:
(
7
!
"
2
/
(
$
2
-
7
6
#
/
6
(
(
7
7
$
(
7
(
9
(
(
*
=
5
(
"
>
(
(
*
?
0
,
9
(
9
'
$
%
-
=
/
(
$
2
-
'
(
(
,
%
+
-
Or
f
i
e
l
d
D
r
a
f
t
i
n
g
S
e
r
v
i
c
e
s
35
0
7
W
5
0
t
h
S
T
Mi
n
n
e
a
p
o
l
i
s
,
M
N
5
5
4
1
0
SHEET:
SCALE:
Cr
o
s
s
S
e
c
t
i
o
n
1/4"=1'0"
DATE:
PR
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
:
SH
E
E
T
T
I
T
L
E
:
Sk
e
t
c
h
#
6
Sl
a
b
o
n
G
r
a
d
e
o
p
t
i
o
n
A-
4
-
12/16/2019
Sketch #6 ODS
HVAC Load Calculations
for
Prepared By:
Duane
Leading Edge Heating & Air
807 Harvest Cir SW
Lonsdale, MN 55046
763-333-5772
Wednesday, December 4, 2019
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ferguson [ Plymouth MN ]Sketch #6 ODS
Plymouth, MN 55441 Page 2
Project Report
General Project Information
Project Title:Sketch #6 ODS
Project Date:Wednesday, December 4, 2019
Company Name:Leading Edge Heating & Air
Company Representative:Duane
Company Address:807 Harvest Cir SW
Company City:Lonsdale, MN 55046
Company Phone:763-333-5772
Design Data
Reference City:Minneapolis/St. Paul AP, Minnesota
Building Orientation:Front door faces East
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-20 -20 n/a 30%70 31.64
Summer:88 71 44%50%75 24
Check Figures
Total Building Supply CFM:643 CFM Per Square ft.:0.505
Square ft. of Room Area:1,275 Square ft. Per Ton:858
Volume (ft³):11,688
Building Loads
Total Heating Required Including Ventilation Air:51,908 Btuh 51.908 MBH
Total Sensible Gain:14,432 Btuh 81 %
Total Latent Gain:3,400 Btuh 19 %
Total Cooling Required Including Ventilation Air:17,833 Btuh 1.49 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\SKETCH #6 ODS - 135064.rh9 Wednesday, December 4, 2019, 1:15 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ferguson [ Plymouth MN ]Sketch #6 ODS
Plymouth, MN 55441 Page 3
System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms)
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
1D-cw-o: Glazing-Double pane, operable window, clear,
wood frame, U-value 0.32, SHGC 0.56
248 7,143 0 8,293 8,293
11J: Door-Metal - Fiberglass Core, U-value 0.6 42 2,268 0 605 605
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
1231.7 7,206 0 1,065 1,065
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
1275 2,295 0 1,224 1,224
22A-pm: Floor-Slab on grade, No edge insulation, no
insulation below floor, any floor cover, passive, heavy
dry or light wet soil, U-value 1.18
166 17,629 0 0 0
Subtotals for structure:36,541 0 11,187 11,187
People:4 800 920 1,720
Equipment:0 0 0
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 85, Summer CFM: 68 8,177 1,049 938 1,987
System 1, Zone 1 Load Totals:44,718 1,849 13,045 14,894
Check Figures
Supply CFM:643 CFM Per Square ft.:0.505
Square ft. of Room Area:1,275 Square ft. Per Ton:1,027
Volume (ft³):11,688
Zone Loads
Total Heating Required:44,718 Btuh 44.718 MBH
Total Sensible Gain:13,045 Btuh 88 %
Total Latent Gain:1,849 Btuh 12 %
Total Cooling Required:14,894 Btuh 1.24 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\SKETCH #6 ODS - 135064.rh9 Wednesday, December 4, 2019, 1:15 PM