Loading...
HomeMy WebLinkAboutLA176672 - 18014 Gresford Lane Permit PackCANNOT HOOK TO CITY SEWER/WATER Giles Brothers Excavating RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 1 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS SCALE: 1/8" = 1'-0" FRONT ELEVATION SEE ROOF PLAN FOR ROOF PITCHES ANDOVERHANGS 25 ' - 6 " CONC. PORCH 4" TRIM TYP. 6:12 6'- 0 " T.O. 3048 SH ALUM. SOFFIT& FASCIA 30 YR. ARCH. ASPHALT SHINGLES 2x OVER 6" TRIM 10" TRIM 12 " L P C O L U M N 6'-0" LP PANEL 9'- 1 1 / 8 " T.O. SUBFLR. T.O. PLATE 1'- 8 1 / 4 " T.O. FDN. 9'- 1 1 / 8 " @ GARAGE T.O. PLATE 12 12 12 12 STAT. (BLACKENED) 2x OVER 10" TRIM 1'- 0 " 7'- 1 1 1 / 2 " T.O. 3048 SHSTAT. (BLACKENED) 3:12 6" T R I M LP P A N E L LP P A N E L 12" CANT. 10" TRIM METAL CORNERS TYP. C/L LP SMARTSIDE SHAKE SIDING 2x OVER 6" TRIM LP P A N E L LP P A N E L T.O. FDN. 8'- 8 " @ DORMERT.O. PLATE 10 ' - 4 " FP CHASE24"x60" FALSE METAL CORNERSTYP. 6" T R I M VINYL SIDING PER SPECS LP SIDING PER SPECS STONE CAP STONE TOTAL: 85.92 SQ. FT. (25.5%) TOTAL SQ. FT.: 337.39 MATERIAL CALCULATIONS: FRONT ELEV. LP LAP SIDING TOTAL: 37.05 SQ. FT. (11%) LP SHAKE TOTAL: 89.01 SQ. FT. (26.4%) LP TRIM / PANEL: 125.41 SQ. FT. (37.1%) STONE TOTAL: 217.52 SQ. FT. (8.7%) TOTAL SQ. FT.: 2,493.84 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 919.28 SQ. FT. (36.9%) LP SHAKE TOTAL: 89.01 SQ. FT. (3.5%) LP TRIM / PANEL: 421.08 SQ. FT. (16.9%) VINYL LAP SIDING TOTAL: 846.95 SQ. FT. (34%) Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 01/06/2020dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET SIDE ELEVATION REAR ELEVATION SIDE ELEVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" @ GARAGE 9' - 1 1 / 8 " T.O. FDN. ALUM. SOFFIT & FASCIA A/C UNIT T.O. PLATE 9' - 1 1 / 8 " T.O. SUBFLR. T.O. FDN. 1'- 8 1 / 4 " 10" TRIM 10" TRIM METAL CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 12:12 12 6 12 6 12 3 T.O. PLATE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 8" TRIM 8' - 8 " @ DORMER T.O. PLATE STONEWHERE INDICATED 2'-0" VINYL SIDING PER SPECS@ GABLE LP SIDING PER SPECS LP SIDING PER SPECS@ DORMER T.O. PLATE 9' - 1 1 / 8 " T.O. SUBFLR. T.O. FDN. 1' - 8 1 / 4 " METAL CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT& FASCIA 6:12 LP SIDING PER SPECS 10" TRIM 12" CANT. 12:12 ALUM. SOFFIT & FASCIA STONE ROOF LINE BEYOND 12 6 T.O. PLATE 9' - 1 1 / 8 " T.O. SUBFLR. T.O. FDN. 1' - 8 1 / 4 " 12 6 10" TRIM 10" TRIM 12" CANT.METAL CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. VINYL SIDING PER SPECS FP VENT SADDLE SEE ROOF PLAN FOR PITCHES AND OVERHANGS LP SIDING PER SPECS @ GABLELP SIDING PER SPECS WHERE INDICATED VINYL SIDING PER SPECS SCALE: 1/8" = 1'-0" FOUNDATION PLAN 3 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS F U T . 3 0 6 8 F U T . 2 6 6 8 FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH FUT. 36" V. CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L.SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE2" FOAM TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG.REQUIRED IN THIS AREA -FIRE BLOCK @ PERIMETEROF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TOTERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILLOVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FORGARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6" 2" CONC.CONC. 3 1 / 2 ' ' C O N C . F L O O R TYP. FND @ HOUSE 8" POURED CONC. (9' H.) 20X8 FTGREBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTGREBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. FU T . 2 4 6 8 OPT. 18 " F L R . T R U S S E S 19 . 2 " O . C . S P A C I N G 2-2x10 (DR) 5/0 BI-PASS (9'-0"x11'-10")(25'-62"x12'-6") RADON VENT FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8" 2" TYP. SIDEWALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 5'-0" 4'- 0 " CONC. WDW WELL 3042 CSMT 2-9 1/2" LSL 2" 2" 2" 2" 9'-0" POURED FDN. APPROX. 1,592 NET SQ. FT. FILL FOR SLAB UP 17 R (10" T., 7-3/4" MAX. R.) 40'-0" 15'-0"12'-0" 56 ' - 0 " 6'- 0 " 50 ' - 0 " 56 ' - 0 " 1'- 0 " 28 ' - 0 " 27 ' - 0 " 14 ' - 4 " 13 ' - 8 " 8'-0 1/2"11'-6" 5'- 0 " 7'- 6 " 14 ' - 6 " 2'- 6 " 40'-0" 20'-0"20'-0" 21'-0" 13'-0"7'-0" & HOUSE/PORCH 10 ' - 0 " 10'-6"9'-6" 18 " F L R . T R U S S E S 19 . 2 " O . C . S P A C I N G 3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) FU T . 2 0 6 8 32 x 6 0 FU T . TU B / S H 4'-3" 2x 1 0 T R T D . J O I S T S 16 " O . C . S P A C I N G 3-2x10 TRTD. (FL) SMOKECM / 12 " C A N T . A B V . 2x6 BRG.2x6 BRG. 18 " F L R . T R U S S E S 19 . 2 " O . C . S P A C I N G 10' H. FOUND. WALL @ FRONT OF HOME NOTE: 10' H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 10' H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 11'-1 1/2"3'-2 1/2"9'-9 3/4"15'-10 1/4" 11'-8 3/4"3'-2"1'-3"3'-0"7'-10"13'-0 1/4" 3'- 9 " 3'- 1 0 " 7'-1 1/2" 21 ' - 3 " 11 ' - 6 " 17 ' - 3 " 10'-1 1/2"10'-4" 30"x30" CONC.PAD FTG. 6x6 COL. 3'-8"4'-11" 16" DIA. FROSTFOOTING (60" D.) 6x6 TRTD. COL. 2-2x10 (DR) 2-2x10 (FL) (2) TR 3-9 1/2" LSL (DR) 5'- 5 " 2'-11"2'-9"2'-4" #1 Grade lumber required or #2 (3)2x12 minimum for span UFER GROUND Provide 20' rebar in footing and stub up near electrical service panel for UFER ground. SCALE: 1/8" = 1'-0" MAIN FLOOR PLAN 4 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET P.H . TB TR DW GAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYERWASHER 9' CLG. / LVP WIRE SH. 29 (OPT. UPPERS) 39 (VENT TO OUTSIDE) NOTE: - STD. BASE & CASING TO BE PRINCETON- 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 )FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. 49KITCHEN 9' CLG. / LVP12'-3" x 12'-6" (155 SQ. FT.) 59 BU I L T - I N S 79 3-14" LVL GREAT ROOM 9' CLG. / LVP FLR. 42 " G A S F . P . 12'-8" x 13'-0" (167 SQ. FT.) / LVP 42" W. CONC. SIDEWALK OP T . FIBRGLS. 60x36 SHWR. UNIT 5'-0" 210 6 8 2-9 1/2" LSL 2x 6 FOYER 9' CLG. / LVP 6'-11" x 7'-1" (51 SQ. FT.) PORCH CONCRETE O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O.4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TOHAVE ONE COAT FIRETAPE GARAGE SL O P E C O N C . 6'x8' PATIO DR. 16'x7' O.H.D.R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET 36 " V A N . BATH 2 BEDROOM #2 2 6 6 8 36 4 8 S H @ 8 ' 9' CLG. / CARPET 9' CLG. / VIN. 1/2 WALL w/ WD. CAP MA N U F . T R U S S E S 24 O . C . OP T . B U F F E T C A B S . (12'-0"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. HEADER SPANS:UP TO 4'-11'' = 1 TRIMMER5'-0'' AND BIGGER = 2 TRIMMERSUNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG. 32 x 6 0 FG L S . TU B / S H (134 SQ. FT.) OWNERS BDRM. 9' CLG. / CARPET(12'-6"x13'-0") (164 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' UP 17 R (10" T., 7-3/4" MAX. R.) 2x6 8/0 H. SOFFIT MANUF. TRUSSES 24 O.C. 12" LP COL.* BEADBD. CLG. AT T I C AC C E S S APPROX. 490 SQ. FT. MUDRM. 9' CLG. / LVP BENCH / APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,592 SQ. FT. HOOKS OPT. PORCH 306 8 M T L . 30 8 0 M T L . R& S H 2 - 2 0 6 8 26 6 8 R& S H 24 6 8 2 6 6 8 206 8 R&SH R& S H LINENSH. 9' CLG. / CARPET 9' CLG. 8' S O F F I T 2 8 6 8 8' SOFFIT (5) SH. (5) SH. 9' CLG. / LVP 26 6 8 R& S H R& S H 36 " V A N . LIN.CAB. 3 0 6 8 3068 PKT. FL D G . C ' T O P . (O P E N U N D E R ) 2 - 4072 SH @ 8' 60 " V A N . DINING 9' CLG. / LVP FLR.10'-0" x 9'-0" (90 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8' 12'x10' DECK DECKING PER SPECS OPT. 15'X10' EXP. DECK MA N U F . T R U S S E S 24 O . C . 40'-0" 15'-0"12'-0" 8'-10"11'-6"12'-11"6'-9" 56 ' - 0 " 6'- 0 " 50 ' - 0 " 12 ' - 8 " 5'- 0 1 / 2 " 5'- 5 1 / 2 " 12 ' - 8 3 / 4 " 7" 3'- 1 1 " 5'- 2 1 / 2 " 4'- 4 3 / 4 " 6'- 2 1 / 4 " 6'- 6 1 / 2 " 56 ' - 0 " 1'- 0 " 28 ' - 0 " 27 ' - 0 " 14 ' - 4 " 13 ' - 8 " 3'- 2 " 8'-0 1/2"11'-6" 5'- 0 " 7'- 6 " 14 ' - 6 " 2'- 6 " 40'-0" 20'-0"20'-0" 21'-0" 13'-0"7'-0" 6'-7"6'-5" 10 ' - 0 " 10'-6"9'-6" RADON VENT 2x6 PA 4"8'-1"4"12'-3" 2-7 1 / 4 " L S L ( D R ) 2-2x8 (DR) 4" LP SOFFIT SD SMOKECM / OPT. VAULT 69 19 BU I L T - I N S OP T . OP T . 2 - 2 6 6 8 P K T . 2'- 4 1 / 4 " 1'- 1 0 1 / 2 " 24 2 4 P I C T . @ 8 ' 24 2 4 P I C T . @ 8 ' 2'- 0 1 / 2 " 2'- 0 1 / 2 " or 3 0 6 8 B A R N D R . OPT. EXP.ISLAND INDICATED STONE WHERE 24 4 8 S H @ 8 ' 5'- 0 " WD. STEP 2'-9" 4'-4"3'-9"2'-9"5'-4 3/4"6'-1 1/4" 6'-1 1/4" 4'-8 3/4"12'-11 1/4" 7'-0 3/4" 2'-0" 1'-4" 7'-10"15'-0 1/2" 2'-7 1/2" 2'- 4 " 6'-2 3/4"3'-6"3'-0 1/2"4'-11 1/2"2'-8 3/4" 2'- 0 " 4'- 0 " 5'- 0 " 12" CANT. 9'- 4 " 5'- 2 " 2'- 6 " 36" H. WALL w/ WD. CAP 1'- 3 " 3 1/2" 3'-10"8" 6'- 8 " 7'- 8 " 4'- 0 " 9'- 8 " 3'- 9 " 3'- 1 0 " 3'- 5 " 3'-5" 3'- 0 " 3'-6"3'-6" 2-2 x 1 0 2- 2 x 1 0 2- 2 x 1 0 2- 2 x 1 0 4 1/2"4 1/2" 8'-10 1/2" MA N U F . T R U S S E S 24 O . C . FP CHASEFALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR (2) TR 2-2x10 2-9 1/2" LSL P.H. TR TB 4x4 TRTD. COL. 59 3068 PKT. 3'-5" MICRO/ OVEN OPT. UPGRADED KITCHEN DW GAS COOKTOPHOOD VENT ABV.(VENT TO OUTSIDE) REF. KITCHEN OPT. EXP.ISLAND Temper Hold-downs needed for minimal panel width per code. PFGPFH 8 8 -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 5 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET SCALE: 3/16" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS5" UP SHEATING UNDER INSTALL TOP OF LEDGER3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLDAT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHINDLEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN.RIM BOARD TREATEDJOIST JOISTRIM BD.SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUSUNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TO P O F F D N . RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDEDIMENSIONS. CANTED 1-1/2" R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 10 " HE E L H T . 1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES 1' - 8 1 / 4 " 9' - 1 1 / 8 " T.O. FOUND. T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL. 10 ' - 0 " GARAGE 4" SLOPED CONC. W/ REBAR PERENGINEERS REPORT 10'-0" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 9'- 1 1 / 8 " O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. NOTE: TOP HUNG TRUSSESAT FRONT OF HOME(10'-0" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'- 1 0 " + / - FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATINGAROUND HOUSE FOUND. 20x8 CONC. FTG. 8 1 / 4 " 6" HE E L H T . 6 12 3 12 4" HE E L H T . 9' - 0 " FUT. BDRM. #5 R.I. BATH 8 1 / 4 " 4" 5'-6" 8'- 8 " 6 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET SCALE: 3/16" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z 4" LEDGE HEADER HURRICANE CLIP ATTACHEDTO COLUMN & BEAM 11 7/8" OSB STRINGERW/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4"MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH 2 BEDROOM #2GREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS ALUM. SOFFIT & FASCIA 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES 1'- 8 1 / 4 " 9'- 1 1 / 8 " T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL. 10 ' - 0 " W/ REBAR PER ENGINEERS REPORT 10'-0" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (10'-0" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8' - 1 0 " + / - FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR CONC. STOOP 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATINGAROUND HOUSE FOUND. PORCH 12" SQ.LP COLUMN 20x8 CONC. FTG. 10 " HE E L H T . 6 12 T.O. FOUND. MECH. / STORAGEFUT. FAMILY ROOM 6 12 9'- 0 " KITCHEN 8 1 / 4 " 4x4 TRTD. COL. 2x OVER 10" TRIM 2 5 3 5 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS ORPUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAINTILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH ENDOF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVERADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THELOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANYOBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FANADDITION. SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BELOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS R-4 ON PIPE IN ATTIC 7 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET SCALE: 1/8" = 1'-0" ROOF PLAN1 7 SA D D L E NOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 8" 1'-0"2' - 0 " 12:12 RI D G E RIDGE 1'-0" 1'- 0 " 1'-6" 16 ' - 6 " 6: 1 2 6: 1 2 3: 1 2 6: 1 2 12:12 2' - 0 " 3'- 0 " 8" 6' - 0 " 8 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET MAIN FLR. ELECTRICAL PLAN SCALE: 1/8" = 1'-0" LOWER LEVEL ELECTRICAL PLAN SCALE: 1/8" = 1'-0" DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D. SS TV AB V . F P . NOTE:TECH TUBE TV W.P . RGH.-IN FAN G.F . I . P . S3 S3 OPT. LTS.PENDANT 3 SS C/L 7'-6"3'-2" 4'- 9 1 / 2 " TV DW GAS RANGEMICRO ABV. LNDRY. DRYERWASHER (VENT TO OUTSIDE) REF. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM. SMOKECM / SD AT T I C AC C E S S MUDRM. DINING SD SMOKECM / GDO G.F.I.P. S G.F.I.P. G.F . I . P . G.F . I . P . W.P. S SS S S SS 3 S3 S3 S 4 G.F . I . P . S 3S 3 S S3 S3 S3 S3 S S3 S S S3 DISP S SS3 S TO LIGHT RGH.-IN FANOPT. SS G.F . I . P . G.F.I.P. G.F . I . P . EXCH.AIR FURN F.D. WH MECH. / STORAGE WS FUT. BDRM. #5FUT. FAMILY ROOM R.I. BATH SUMP H20 OPT. RADON VENT SMOKECM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F . I . P . G.F . I . P . 9 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 OF SHEET 2' - 1 1 1 / 4 " 5'-0" BATH 2 ELEV. 9 6 SCALE: 1/4"=1'-0" 7' - 0 " MIRROR SPACE WASH. LNDRY. ELEV. SCALE: 3/8"=1'-0" DRYER SPACE 30 " CROWN MOULDING 9 8 C'TOP RAISED OPT. 2" SUPPORT w/ FRONTLOAD W&D 3' - 5 " 2' - 1 1 1 / 4 " 3'- 0 " 7' - 0 " WALL MOUNT 7'-9" O. BATH ELEV. 9 7 SCALE: 3/8"=1'-0" 3'-0"1'-9"3'-0" MARBLE C'TOP.WHITE CULT. NOTE: OPT. w/ RAISED TOP WALL MOUNT MIRROR MARBLE C'TOP.WHITE CULT. NOTE: 5 OPT. BUILT-INS @ DINING ELEV. 9 SCALE: 3/8"=1'-0" CROWN MOULDING GRANITE TOP w/ OPT. BUILT-INS GL A S S GL A S S GL A S S GL A S S NOTE: PUCK LTS. ATGLASS DOORS 15" D. 1'-9"1'-9"5'-5 1/4" 2'-6"2'-6" 49 " + / - NO HEARTH PER SPECS 12" SURROUND @ FRONT ONLY 42" W.GAS F.P.R.O. 42"x 38 1/4" x 16 1/4" GATHERING RM. F.P. ELEV. 9 1 SCALE: 3/8"=1'-0" MANTLE PER SPECS 3' - 0 " 3'-0" 5'-0" 4 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 67" FIN. 2 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 2'-0" REFRIG. SPACE 2'- 0 " 3'-0" 24" DEEP CROWN MLDG END PANEL 2'-0" 3 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" (SHTRCK. @ SIDES) 60" TV (REF. ONLY) 3'-8 1/2" 2' - 0 " 3'-0"2'-0" 12'-6" D.W. SPACE SINK 1'-6"3'-0" CROWN 4'-6"3'-0" MLDG 2'-0"2'-6" 15" D. MICRO RANGE SPACE (VENT TO OUTSIDE) 1'-6" 1'-9" 3'-0" OPT. BUILT-INS 3'-0" 1'-0"1'-9" 3' - 0 " 12'-3" 1'-0" OPT. BUILT-INS 3'-8 1/4" 2 UPGRADED KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 3'-0"2'-0" 12'-6" D.W. SPACE SINK 1'-0"10" CROWN 2'-4"2'-6" MLDG 3'-0" 3' - 0 " 1'-0" 2'-0" REFRIG. SPACE 2' - 0 " 3'-0" 24" DEEP CROWN MLDG END PANEL 2'-0" 3 9 SCALE: 3/8"=1'-0" 2'-6" 15" D. 1'-6" 1'-9" 3'-0" 1'-0"1'-9" 12'-3" UPGRADED KITCHEN ELEV. COOKTOPOVEN /MICRO 2'-8" (VENT TOOUTSIDE) HOOD VENT BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X LO T 3 , B L O C K 7 , S U M M E R S C R E E K LA K E V I L L E "C H A R L E S T O N " V I L L A H O M E S P E C . MA R K E L L I O T T H O M E S 11-8-19 PERMIT 12-27-19 BW 1-9-2020 REV. #1 SHEETN.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS4 BW MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10 ' - 0 ' ' M A X . H E I G H T ( T O P O F H D R . ) TOP OF FDN.TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING ISREQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER 12 ' - 0 ' ' M A X . H E I G H T ( T O P O F W A L L ) FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICES PO N Y W A L L H T . EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OFSHEATHING ANCHOR BOLTSPER SECTIONR403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITHWOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FORTYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MI N . O V E R L A P 9 1 / 4 ' ' WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOIST MI N . O V E R L A P 9 1 / 4 ' ' ATTACH TO RIM/BAND JOIST W/ 8dCOMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C.W/ 6d NAILS @ 6'' O.C. 4'-0" 8'- 0 ' ' M I N . , S E E P L A N INTERMEDIATE 6'' 3" W/ 6d NAILS @ 3'' O.C.EDGES NAILED LNDRY. DRYERWASHER KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM. AT T I C AC C E S S MUDRM. DINING GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP 3'-2" PANEL 4'- 0 " P A N E L 4'- 0 " P A N E L 4'- 0 " P A N E L 4'- 0 " P A N E L 4'- 0 " P A N E L BR A C E D W A L L LI N E 1 BRACED WALLLINE A BRACED WALLLINE C BR A C E D W A L L LI N E 2 4'- 0 " P A N E L 4'- 0 " P A N E L 4'- 0 " P A N E L 4'- 0 " P A N E L 3'-2" PANEL 3'-5" PANEL 3'-5" PANEL6'-7" PANEL 3'-1" PANEL BRACED WALLLINE B8'-0" GYP. PANEL 8'-0" GYP. PANEL 1'-10" PANEL 1'-10" PANEL NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is reqXired for ³ConstrXction actiYit\ that resXlts in land distXrbance of eqXal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,´ (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. ³Permittees mXst ensXre a trained person Zill inspect the entire constrXction site at least once eYer\ seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hoXrs,´ (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 KP X01/10/2020