HomeMy WebLinkAboutItem 6
3601 Thurston Avenue
Anoka, MN 55303
763.231.5840
TPC@PlanningCo.com
1
MEMORANDUM
TO: Daryl Morey
FROM: D. Daniel Licht, AICP
DATE: 23 January 2020
RE: Lakeville – Pinnacle Reserve at Avonlea
TPC FILE: 135.01
BACKGROUND
DR Horton has submitted applications for the following within Pinnacle Reserve at Avonlea:
PUD Development Stage Plan and preliminary and final plat for development of an
amenity park and community building on Outlot I, Pinnacle Reserve at Avonlea.
Amendment of the Avonlea PUD District to approve plans for the HOA maintained single
family homes to be constructed within Pinnacle Reserve at Avonlea.
The subject site is zoned PUD, Planned Unit Development District in accordance with the PUD
Development Stage Plan and Ordinance approved by the City Council on 6 April 2015. A public
hearing to consider the applications has been noticed for the Planning Commission meeting on
6 February 2020.
Exhibits:
A. Site Location Map
B. Project Narrative
C. Amenity Park Site and Landscape Layout Exhibit
D. Amenity Park Grading Exhibit
E. Amenity Park building front elevation
F. Amenity Park building floor plan
G. Preliminary/Final Plat
H. Pinnacle Reserve Overall Preliminary Landscape Plan
I. Freedom Homes color renderings (12 pages)
J. Freedom Homes elevation plans (15 pages)
2
ANALYSIS
Amenity Park and Community Building. The PUD Development Stage Plan for Pinnacle
Reserve at Avonlea PUD designated Outlot I, Pinnacle Reserve at Avonlea for development of
an HOA recreation amenity:
Lot Requirements. There is no minimum lot area or lot width applicable to the subject
site established by the Avonlea PUD District.
Setbacks. The table below summarizes the setbacks required by the Avonlea PUD
District and Zoning Ordinance for the community building and pickleball courts within
the subject site:
183rd St. Hamby Way. East South
Required 20ft. 20ft 14ft. 25ft.
Building 25ft. 85ft. 10ft. 85ft.
Courts 52ft. 20ft. 106ft. 25ft.
The Zoning Ordinance requires community buildings to provide a side yard setback
double that required by the underlying zoning but not more than 30 feet, which for the
proposed building is 14 feet applicable to the east lot line. The proposed community
building is setback only 10 feet from the east lot line. The site plan must be revised to
shift the proposed building 4 feet to the west. The community building and pickleball
court comply with all other setback requirements.
Building Design. The proposed community building is a single story structure with
pitched roof and gables consistent with the character of the planned houses to be built
upon the HOA maintained single family lots. The developer indicates that the building
will have exterior finish materials consisting of brick accents, cement fiber horizontal lap
siding, and asphalt shingles. The developer has provided a color illustration of the
proposed exterior that only shows the front (north) elevation but must identify the
exterior materials to be used on the other 3 elevations and verify compliance with the
requirements of Section 6.D of the Avonlea PUD District requiring a minimum 25
percent brick or stone on the front elevation.
Landscaping. The subject site is at a comparable elevation to the single family lot to the
east and approximately 5 feet below the rear elevation of the building pad on the single
family lot to the south. The developer has submitted a landscape plan that provides for
a staggered row of evergreen trees along the east and south property lines to screen the
community building and pickleball courts from the abutting single family lots. There are
also 3 evergreen trees to the north of the pickleball courts and 4 shade trees in the
yards along 183rd Street and Hamby Way. The proposed landscaping is consistent with
the overall landscape plan approved for Pinnacle Reserve at Avonlea with the PUD
Development Stage Master Plan.
3
We recommend either an evergreen hedge or 6 foot privacy fence be added along the
east lot line from the front line of the community building to the proposed evergreen
trees to provide a more complete buffer. The location for mechanical equipment is not
shown and must be screened from view by a fence enclosure or landscaping. The type
and sizes of all proposed plantings are not specified and must be identified to verify
compliance with the requirements of Section 11-21-9.C of the Zoning Ordinance.
Off-Street Parking. Section 11-19-13 of the Zoning Ordinance requires community
center buildings to provide 10 parking stalls plus one parking stall for each 300 square
feet of principal building area greater than 2,000 square feet. The proposed building is
712 square feet in area requiring 10 off-street parking stalls. However, the site plan
does not include off-street parking facilities.
The amenity park is to be owned and accessible by the HOA for the 84 surrounding HOA
maintained lots within Pinnacle Reserve at Avonlea. Most of these lots are within 500
feet of the amenity park, with the farthest lot within a still walkable 1,300 feet. There is
also 266 feet of street frontage abutting the subject site available for on-street parking
for 10 vehicles. Based on these circumstances, exception from the off-street parking
requirement of the Zoning Ordinance is acceptable under the PUD Development Stage
Plan for the amenity park.
Exterior Lighting. The submitted plans do not identify exterior lighting fixtures either on
the community building or pickleball court. The developer must provide an exterior
lighting plan indicating the location, type, and height of all exterior light fixtures and a
photometric plan illustrating the intensity of the proposed exterior lighting in
compliance with Section 11-16-17 of the Zoning Ordinance.
Trash. No trash storage facilities are identified on the site plan or floor plan of the
community building. The developer must indicate if trash and recycling containers are
to be stored within the building or within an exterior enclosure that complies with the
requirements of Section 11-18-11 of the Zoning Ordinance. If an exterior enclosure is
planned, then plans for the enclosure constructed of materials consistent with that of
the principal building must be submitted prior to City Council consideration of the
applications.
Grading Plan. The developer has submitted a grading plan for development of the
subject site. All grading, drainage, and utility issues are subject to review and approval
of the City Engineer.
Utility Plan. A plan for connection of the community building to sanitary sewer and
water utilities is not shown on the submitted plans. Connection of the community
building to sanitary sewer and water utilities is subject to review and approval of the
City Building Official with application for a building permit.
4
Park Dedication. Section 10-8-4 of the Subdivision Ordinance addresses park dedication
requirements applicable to final plats. The preliminary plat approval for Pinnacle
Reserve at Avonlea provides for a combination of dedication of land and payment of
cash fees for each single family lot. The proposed private open space is included in the
calculation of land dedicated for park purposes for the preliminary plat. Section 10-4-
8.G of the Subdivision Ordinance allows the City to credit private recreational facilities
for park dedication purposes, so no cash fee will be required as part of the proposed
final plat.
Performance Agreement. There are no public improvements associated with the final
plat requiring a development agreement under Section 10-5-1 of the Subdivision
Ordinance. Section 11-93-23.E of the Zoning Ordinance requires the developer to enter
into a site improvement performance agreement (SIPA) with the City. The agreement
will provide for completion of the improvements identified on the submitted plans and
posting of financial securities. The SIPA will be drafted by the City Attorney and is
subject to approval of the City Council.
Exterior Material Requirements. The single family dwellings to be constructed on the HOA
maintained lots are subject to the exterior finish requirements of the Avonlea PUD District
unless otherwise approved by the Planning Commission and City Council in accordance with
Section 6 of the Avonlea PUD District. The RST-2 District and Avonlea PUD District require use
of brick or stone exterior finish materials for a minimum of 25 percent of the front elevation.
Cement fiberboard or engineered wood siding having varied color and texture is required to be
used for the remainder of the exterior finish material on the front elevation and the entire side
and rear elevations.
House Plan % Brick/Stone Material on Front Elevation
Base Optional
Bristol A-Front 10.0% 16.9%
B-Front 9.8% 15.8%
C-Front 12.0% 17.3%
Clifton A-Front 9.0% 25.1%
B-Front 10.0% 15.6%
C-Front 11.3% 16.0%
Dover A-Front 20.1% --
B-Front 20.3% --
C-Front 17.3% --
Morgan A-Front 24.7% Not specified
B-Front 17.6% Not specified
C-Front 19.5% Not specified
Lewis A-Front 16.3% --
B-Front 20.0% --
C-Front 18.3% --
5
The developer is proposing 5 house plans each with 3 front elevation choices for the HOA
maintained lots. None of the proposed front elevations use a minimum of 25 percent brick.
The Bristol and Clifton house plans have an optional front elevation that increases the area of
brick or stone, but only 1 of these 6 front elevations meet the minimum 25 percent
requirement. The Morgan house plan has an optional second story but the area of the second
story visible from the front elevation (that would increase the area of the front elevation) is not
included in the calculation of brick or stone materials (decreasing the percentage of brick or
stone material).
The developer is requesting approval of the proposed elevations with less than 25 percent brick
or stone used on the front elevation for the proposed houses on the HOA maintained lots. The
basis of this request is that each of the front elevation plans incorporate 2 or more roof gables
to add variation to the structure and incorporation of varied materials. The brick or stone
exterior finish material used for each front elevation on the proposed plans is a horizontal
wainscoting that rises to the base of the front window or mid-point of the front window on the
optional Bristol and Clifton house plans in a manner appropriate for the design of the building.
Combined with use of cement fiber or engineered wood on all sides of the building, the exterior
finish of the proposed single family dwelling plans maintains the aesthetic and quality intended
within the Avonlea PUD District.
City staff suggests that the area of brick or stone used for the front elevation could include the
entire area of the elevation surrounding the front window section and/or garage face. Making
available to buyers the option to increase brick or stone in this manner would further add
variation to the streetscape and either comply with or come closer to complying with the
minimum 25 percent requirement. The Planning Commission may consider adding a condition
of approval stipulating the developer provide an option for additional brick on the front façade
to include the area surrounding either/both the front window or the garage face.
CONCLUSION
Our office recommends approval of the PUD Development Stage Plan and preliminary and final
plat for Pinnacle Reserve at Avonlea 2nd Addition and the amendment to the Avonlea PUD
subject to the following conditions outlined below:
1. The site plan shall be revised such that the community building is setback 14 feet from
the east lot line.
2. The exterior materials to be used on all elevations of the community building shall be
submitted and shall comply with the requirements of Section 6.D of the Avonlea PUD
District.
3. The landscape plan shall be revised to add an evergreen hedge or 6 foot privacy fence
along the east lot line from the front line of the community building to the proposed
evergreen trees.
6
4. The location and screening of ground mounted mechanical equipment for the
community building shall be specified and is subject to approval of the Zoning
Administrator.
5. The type and sizes of all proposed plantings shown on the landscape plan shall be
identified to verify compliance with the requirements of Section 11-21-9.C of the Zoning
Ordinance.
6. The developer shall provide an exterior lighting plan indicating the location, type, and
height of all exterior light fixtures and a photometric plan illustrating the intensity of the
proposed exterior lighting in compliance with Section 11-16-17 of the Zoning Ordinance.
7. Any exterior storage of trash or recycling containers shall be within an enclosure that
complies with the requirements of Section 11-18-11 of the Zoning Ordinance
constructed of materials consistent with that of the principal building.
8. All grading, drainage and erosion control issues are subject to review and approval of
the City Engineer.
9. All utility issues are subject to review and approval of the Building Official at the time
application for a building permit.
10. The developer shall execute a site improvement performance agreement with the City
as drafted by City Attorney and subject to approval of the City Council.
11. The developer shall make available an option to include brick/stone on the entire front
façade surrounding either/both the front window and garage face.
c. Justin Miller, City Administrator
Alex Jordan, Assistant City Engineer
John Hennen, Parks and Recreation Director
Andrea McDowell-Poehler, City Attorney
±
185TH ST HAMBURGAVEOutlot I
City of Lakeville
Pinnacle Reserve at Avonlea
Outlot I
Site Location Map
183RD STH
AMELDR186TH ST
EXHIBIT A
EXHIBIT B
Phone (952) 937-5150 12701 Whitewater Drive, Suite #300
Fax (952) 937-5822 Minnetonka, MN 55343
Toll Free (888) 937-5150
EXHIBIT C
Phone (952) 937-5150 12701 Whitewater Drive, Suite #300
Fax (952) 937-5822 Minnetonka, MN 55343
Toll Free (888) 937-5150
EXHIBIT D
EXHIBIT E
EXHIBIT F
EXHIBIT G
EXHIBIT H
EXHIBIT I
EXHIBIT J
From:Casey Wollschlager
To:Morey, Daryl
Cc:Joann Wollschlager; Mark Pasvogel
Subject:Pinnacle Reserve 2nd Addition
Date:Tuesday, January 28, 2020 9:24:12 AM
Attachments:image001.jpg
Daryl,
I wanted to share an opinion about the suggested change to allow for less stone on the Detached
Townhomes on the DR Horton buildings in Pinnacle Reserve/Avonlea. The project that we
developed right next door(Summers Creek) has a requirement of 25% brick on every detached
townhome. Allowing ANY other project to have less than that is completely unfair. As I have
discussed with you in the past, the cost impact of the brick and more expensive siding (LP/Hardy) on
all sides of the homes is adding an additional $12,000-$20,000 per home for no reason. Keeping the
playing field even for EVERY business owner and future resident is requirement for the city. Allowing
one builder or development to have a significant cost advantage by not requiring the same building
materials is a problem for the economics of local builders and developers. Avonlea has already
received their PUD benefits years ago by getting increased density and smaller than normal lot sizes.
Giving additional benefits now is again unfair. Unless the city wants to change the
requirement(Ordinances) for all developments and builders across the whole community to create
more affordability, then all developments/builders should share the same rules.
Please share this email in the public comments section of the Planning Commission and City Council.
Thank You,
Casey Wollschlager
COO Summergate Companies
SUMMER-GATE.COM
952-898-3461