HomeMy WebLinkAboutLA177065 8080 201st St W Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode01/30/2020dmathews
(3)2x12 min for span unlessusing #1 Grade SP and then(3)2x10 ok.SmokeSmokeSmokeCOUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).SmokeSmokeSmokeCOSmokeCOCS-PFCS-PFCS-PF
Stone Cottage
HVAC Load Calculations
for
Berquist
8080 201st St W
Lakeville,mn
Prepared By:
Randy Andrews
Lofgren Heating
5708 Upper 147th Street West
Apple Vallley, MN 55124
Monday, January 13, 2020
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 2
Project Report
General Project Information
Project Title:Stone Cottage
Project Date:Monday, January 13, 2020
Client Name:Berquist
Client Address:8080 201st St W
Client City:Lakeville,mn
Company Name:Lofgren Heating
Company Representative:Randy Andrews
Company Address:5708 Upper 147th Street West
Company City:Apple Vallley, MN 55124
Company E-Mail Address:rrandrews@lofgrenheating-ac.com
Design Data
Reference City:Minneapolis, Minnesota
Building Orientation:Front door faces Northeast
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Elevation Sensible Adj. Factor:1.000
Elevation Total Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -15.33 80%n/a 72 n/a
Summer:88 72 47%50%75 29
Check Figures
Total Building Supply CFM:1,369 CFM Per Square ft.:0.415
Square ft. of Room Area:3,300 Square ft. Per Ton:992
Volume (ft³) of Cond. Space:31,350
Building Loads
Total Heating Required Including Ventilation Air:50,383 Btuh 50.383 MBH
Total Sensible Gain:29,947 Btuh 84 %
Total Latent Gain:5,528 Btuh 16 %
Total Cooling Required Including Ventilation Air:35,475 Btuh 2.96 Tons (Based On Sensible + Latent)
3.33 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 3
Load Preview Report
Scope
Has
AED
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 2.96 1,116 3,300 29,947 5,528 35,475 50,383 846 1,369 1,369
System 1 No 2.96 1,116 3,300 29,947 5,528 35,475 50,383 846 1,369 1,369 24x10
Ventilation 728 1,352 2,080 9,749
Zone 1 3,300 29,219 4,176 33,395 40,634 846 1,369 1,369 24x10
1-Upper Level 1,650 20,630 2,675 23,305 25,664 534 967 967 11--6
2-Lower Level 1,650 8,589 1,501 10,090 14,970 312 402 402 5--6
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 4
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
428 11,916 0 12,766 12,766
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
1726 9,761 0 1,492 1,492
15B0-15sf-10: Wall-Basement, , R-15 board insulation to
floor, no interior finish, 10' floor depth
1188 4,342 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1650 2,871 0 1,584 1,584
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1090 2,371 0 0 0
Subtotals for structure:32,539 0 16,194 16,194
People:9 1,800 2,070 3,870
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 87, Summer CFM: 45 8,095 876 629 1,505
Ventilation: Winter CFM: 140, Summer CFM: 70 9,749 1,352 728 2,080
AED Excursion:0 0 4,326 4,326
Total Building Load Totals:50,383 5,528 29,947 35,475
Check Figures
Total Building Supply CFM:1,369 CFM Per Square ft.:0.415
Square ft. of Room Area:3,300 Square ft. Per Ton:992
Volume (ft³) of Cond. Space:31,350
Building Loads
Total Heating Required Including Ventilation Air:50,383 Btuh 50.383 MBH
Total Sensible Gain:29,947 Btuh 84 %
Total Latent Gain:5,528 Btuh 16 %
Total Cooling Required Including Ventilation Air:35,475 Btuh 2.96 Tons (Based On Sensible + Latent)
3.33 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 5
Building Pie Chart
Building
Loss
50,383
Btuh
Floor 5%
Roof 6%
Wall 28%
Glass 24%
Door 3%
Infiltration 16%
Ventilation 19%
Building
Gain
35,475
Btuh
Roof 4%Wall 4%
Glass 36%
Door 1%People 11%
Equipment 21%
Infiltration 4%
Ventilation 6%
AED Excursion 12%
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 6
System 1 Whole House Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
428 11,916 0 12,766 12,766
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
1726 9,761 0 1,492 1,492
15B0-15sf-10: Wall-Basement, , R-15 board insulation to
floor, no interior finish, 10' floor depth
1188 4,342 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1650 2,871 0 1,584 1,584
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1090 2,371 0 0 0
Subtotals for structure:32,539 0 16,194 16,194
People:9 1,800 2,070 3,870
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 87, Summer CFM: 45 8,095 876 629 1,505
Ventilation: Winter CFM: 140, Summer CFM: 70 9,749 1,352 728 2,080
AED Excursion:0 0 4,326 4,326
System 1 Whole House Load Totals:50,383 5,528 29,947 35,475
Check Figures
Supply CFM:1,369 CFM Per Square ft.:0.415
Square ft. of Room Area:3,300 Square ft. Per Ton:992
Volume (ft³) of Cond. Space:31,350
System Loads
Total Heating Required Including Ventilation Air:50,383 Btuh 50.383 MBH
Total Sensible Gain:29,947 Btuh 84 %
Total Latent Gain:5,528 Btuh 16 %
Total Cooling Required Including Ventilation Air:35,475 Btuh 2.96 Tons (Based On Sensible + Latent)
3.33 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 7
Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,650.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,650.0 sq.ft.Supply Air:967 CFM
Ceiling Height:10.0 ft.Supply Air Changes:3.5 AC/hr
Volume:16,500.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:11 Actual Winter Vent.:88 CFM
Runout Air:88 CFM Percent of Supply.:9 %
Runout Duct Size:6 in.Actual Summer Vent.:49 CFM
Runout Air Velocity:448 ft./min.Percent of Supply:5 %
Runout Air Velocity:448 ft./min.Actual Winter Infil.:67 CFM
Actual Loss:0.125 in.wg./100 ft.Actual Summer Infil.:35 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
SW-Wall-12F-0sw 56 X 9 316 0.065 5.7 1,787 0.9 0 273
NE-Wall-12F-0sw 56 X 9 424 0.065 5.7 2,398 0.9 0 367
NW-Wall-12F-0sw 38 X 9 308 0.065 5.7 1,742 0.9 0 266
SE-Wall-12F-0sw 38 X 9 334 0.065 5.7 1,889 0.9 0 289
NE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
NE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
SW-Gls-4A-1a-o shgc-0.33 0%S 188 0.320 27.8 5,234 31.0 0 5,824
NE-Gls-4A-1a-o shgc-0.33 0%S 38 0.320 27.8 1,058 24.1 0 917
NW-Gls-4A-1a-o shgc-0.33 0%S 34 0.320 27.8 947 24.1 0 821
SE-Gls-4A-1a-o shgc-0.33 0%S 8 0.320 27.8 223 31.0 0 248
UP-Ceil-16B-50 1650 X 1 1650 0.020 1.7 2,871 1.0 0 1,584
Subtotals for Structure:19,427 0 10,941
Infil.: Win.: 67.2, Sum.: 34.9 1,692 3.686 6,237 0.287 675 485
AED Excursion:3,054
People: 200 lat/per, 230 sen/per:5 1,000 1,150
Equipment:1,000 5,000
Room Totals:25,664 2,675 20,630
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 8
Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,650.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,650.0 sq.ft.Supply Air:402 CFM
Ceiling Height:9.0 ft.Supply Air Changes:1.6 AC/hr
Volume:14,850.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:5 Actual Winter Vent.:52 CFM
Runout Air:80 CFM Percent of Supply.:13 %
Runout Duct Size:6 in.Actual Summer Vent.:21 CFM
Runout Air Velocity:410 ft./min.Percent of Supply:5 %
Runout Air Velocity:410 ft./min.Actual Winter Infil.:20 CFM
Actual Loss:0.105 in.wg./100 ft.Actual Summer Infil.:10 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
SW-Wall-12F-0sw 56 X 9 344 0.065 5.7 1,945 0.9 0 297
NE-Wall-15B0-15sf-10 56 X 9 504 0.042 3.7 1,842 0.0 0 0
NW-Wall-15B0-15sf-10 38 X 9 342 0.042 3.7 1,250 0.0 0 0
SE-Wall-15B0-15sf-10 38 X 9 342 0.042 3.7 1,250 0.0 0 0
SW-Gls-4A-1a-o shgc-0.33 0%S 160 0.320 27.8 4,454 31.0 0 4,956
Floor-21A-24 1 X 1090 1090 0.025 2.2 2,371 0.0 0 0
Subtotals for Structure:13,112 0 5,253
Infil.: Win.: 20.0, Sum.: 10.4 504 3.687 1,858 0.286 201 144
AED Excursion:1,272
People: 200 lat/per, 230 sen/per:4 800 920
Equipment:500 1,000
Room Totals:14,970 1,501 8,589
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 9
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Upper Level 1,650 25,664 534 11-6 448 20,630 2,675 967 967
2 Lower Level 1,650 14,970 312 5-6 410 8,589 1,501 402 402
Ventilation 9,749 728 1,352
System 1 total 3,300 50,383 846 29,947 5,528 1,369 1,369
System 1 Main Trunk Size:24x10 in.
Velocity:821 ft./min
Loss per 100 ft.:0.094 in.wg
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:2.96 84% / 16%29,947 5,528 35,475
Recommended:3.33 75% / 25%29,947 9,982 39,930
Actual:1.00 77% / 23%9,240 2,760 12,000
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:QC-F38-E78-G QC-C12
Indoor Model:S12
Brand:Quikcool FE Series Quikcool AS Series
Description:Hi Efficiency Furnace Standard Efficiency Air Condit
Efficiency:78.3 AFUE 12.4 SEER
Sound:8.1 bels
Capacity:38,000 Btuh 12,000 Btuh
Sensible Capacity:n/a 9,240 Btuh
Latent Capacity:n/a 2,760 Btuh
C:\ ...\8080 201ST ST LAKEVILLE 01132020.rhv Monday, January 13, 2020, 11:50 AM
Builders Associaton of Minnesota version 101014
Date Certificate Posted
x Passive (No Fan)
Active (With fan and monometer or
other system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
x
10/15 x x
x
20 x
20 x
21 x
49 x
x
x
x
x Not applicable, all ducts located in conditioned space
x Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
70,000 Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%
93%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
x Passive
Low: Other, describe:
x Low:
Location of fan(s), describe: Cfm's
4" " round duct OR Flex
" metal duct
ML193UH070
Heating Loss
Manufacturer Lennox
Natural Gas
Output in
Tons:
3 Ton50
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
200CFM
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
29,947Residential Load Calculation
SEER
/EER
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
AO Smith
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency 13 Seer
Building envelope air tightness:
Rim Joist (1st Floor)
GPVL-50 13ACXN042-230 Model
Heating System
Natrual Gas
Lennox Fiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door) U:
Duct system air tightness:
Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell0.22
Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not ApplicableAttic
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.30
Appliances
Mech Room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
50,383
Heating Gain Cooling Load
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.
Place your
logo here
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
Stone Cottage Construction Inc.
MN License Number
Lakeville8080 201st St W
BC636874
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
35,475
Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities
in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater
Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least
once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.”
(NPDES Construction Stormwater Permit, MPCA)
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
KP
01/21/2020 X