Loading...
HomeMy WebLinkAboutLA177786 - 5637 Upper 179th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode03/03/2020dmathews 3UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.6PFHCS-PFor PFHCS-PFor PFH -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). Foundation will be pouredwalls and not block. Continuous sheathed portalframe or portal frame withhold-downs required for ceilingheight and limited panel width.Portal frame with hold-downrequired for limited panelwidth and ceiling height. 5637 Upper 179th St. W., Lakeville HVAC Load Calculations for Cedarline Construction LLC Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Monday, February 10, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:5637 Upper 179th St. W., Lakeville Designed By:Jake Ryan Project Date:1/27/2020 Project Comment: Client Name:Cedarline Construction LLC Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces South Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%70 31.52 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:814 CFM Per Square ft.:0.296 Square ft. of Room Area:2,750 Square ft. Per Ton:1,357 Volume (ft³):22,000 Building Loads Total Heating Required Including Ventilation Air:42,661 Btuh 42.661 MBH Total Sensible Gain:18,072 Btuh 74 % Total Latent Gain:6,250 Btuh 26 % Total Cooling Required Including Ventilation Air:24,323 Btuh 2.03 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.03 1,357 2,750 18,072 6,250 24,323 42,661 503 814 503 814 814 System 1 Main Floor No 2.03 1,357 2,750 18,072 6,250 24,323 42,661 503 814 503 814 814 10x15 Ventilation 687 3,480 4,167 5,035 Supply Duct Latent 140 140 Return Duct 9 24 33 58 Humidification 5,253 Zone 1 2,750 17,377 2,606 19,983 32,316 503 814 503 814 814 10x15 1-Basement 1,130 3,442 400 3,842 11,207 174 161 174 161 161 2--5 2-Main Level 1,130 10,462 2,006 12,468 13,178 205 490 205 490 490 4--7 3-Upper Level 490 3,473 200 3,673 7,931 123 163 123 163 163 2--5 F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 591.3 174 161 161 2--5 2-Main Level Built-In 450 750 0.01 0.1 458.5 205 490 490 4--7 3-Upper Level Built-In 450 750 0.01 0.1 596.7 123 163 163 2--5 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 781.5 503 814 814 10x15 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:503 Cooling Flow:814 F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 271.6 7,386 0 4,031 4,031 11J: Door-Metal - Fiberglass Core, U-value 0.6 37.8 1,927 0 544 544 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2338.6 12,921 0 2,023 2,023 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 432 1,982 0 0 0 RJ R-20: Wall-Frame, Custom, RJ R-20 RIM JOIST R20 SPRAY FOAM, U-value 0.05 325.9 1,386 0 282 282 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 1620 2,754 0 2,203 2,203 21A-32: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide, U-value 0.02 1130 1,921 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover, U-value 0.035 490 1,458 0 137 137 Subtotals for structure:31,735 0 9,220 9,220 People:9 1,800 2,070 3,870 Equipment:806 3,334 4,140 Lighting:750 2,558 2,558 Ductwork:638 164 138 302 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 150, Summer CFM: 150 5,035 3,480 687 4,167 Humidification (Winter) 14.32 gal/day :5,253 0 0 0 AED Excursion:0 0 66 66 Total Building Load Totals:42,661 6,250 18,072 24,323 Check Figures Total Building Supply CFM:814 CFM Per Square ft.:0.296 Square ft. of Room Area:2,750 Square ft. Per Ton:1,357 Volume (ft³):22,000 Building Loads Total Heating Required Including Ventilation Air:42,661 Btuh 42.661 MBH Total Sensible Gain:18,072 Btuh 74 % Total Latent Gain:6,250 Btuh 26 % Total Cooling Required Including Ventilation Air:24,323 Btuh 2.03 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces South Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 161 218 255 235 191 244 *259 218 3--5 2 Main Level 490 551 580 560 513 576 *582 546 5--6 3 Upper Level 163 181 185 169 144 177 *191 183 2--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°South 814 18,072 6,250 2.03 45°Southwest 950 20,982 6,250 2.27 90°West 1,020 22,466 6,250 2.39 135°Northwest 963 21,251 6,250 2.29 180°North 848 18,790 6,250 2.09 225°Northeast 997 21,977 6,250 2.35 270°East *1,031 *22,705 6,250 *2.41 315°Southeast 947 20,914 *6,251 2.26 * Indicates highest value of all rotations. 2.0 2.1 2.2 2.3 2.4 South Southwest West Northwest North Northeast East SoutheastCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5637 Upper 179th St. W., Lakeville Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 22,000 23,000 24,000 25,000 26,000 27,000 28,000 29,000 30,000 31,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast F:\ ...\5637 Upper 179th St. W., Lakeville - Heat Calc.rh9 Monday, February 10, 2020, 9:45 AM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 02/25/2020 X KP