Loading...
HomeMy WebLinkAboutLA177992 5662 Upper 179th St Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 03/03/2020 X KP Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 03/12/2020shutchins 3 5-1/4" x 5-1/4" VERSA-LAM 444 (1)11-7/8 LSL3 5.5" of bearing required (1)11-7/8 LSL(3) 14" VERSA-LAM (2)2x12 22x30 ATTIC ACCESS PFH PFH WSP WSPWSP44 4 WSP 8 WSP WSP 12 3334 WSPWSPWSPWSP WSP 12 (2) 9-1/2" VERSA-LAM WSP WSPWSP4 8 LIB LIB 8 8 LIB LIB 8 8 LIB WSP Smoke required for cantilever.BCI joist blocking23/32" min. plywood/OSBinto each flange.Nail with 8d nailsor rimboard closure.®F05Boise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-Acut, notch or drill flangesDO NOTDN01 000000Builders Associaton of Minnesota version 101014 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 5662 Upper 179th St W Lakeville Name of Residential Contractor MN License Number Brandl Anderson Homes BC604388 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply x Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Attic Other Please Describe Here Below Entire Slab x Foundation Wall R-15 x R-5 where required Perimeter of Slab on Grade x Rim Joist (1st Floor)R-20 x x R10 Rigid Exterior, R10 Int closed cell Rim Joist (2nd Floor+)R-20 x x R10 Rigid Exterior, R10 Int closed cell Wall 19+5 x x R5 Exterior, R19 Batts Ceiling, flat R-49 x Ceiling, vaulted R-49 x Bay Windows or cantilevered areas R-38 x Floors over unconditioned area R-38+5 x x Describe other insulated areas Building envelope air tightness:Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.30 X R-value R-8 MECHANICAL SYSTEMS Make-up Air Select a Type 000000Builders Associaton of Minnesota version 101014 Appliances Heating System Domestic Water Heater Cooling System x Not required per mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Lennox Lennox Powered Model ML193UH045 13ACXN018 Interlocked with exhaust device.Describe: Rating or Size Input in BTUS:44,000 Capacity in Gallons:50 Output in Tons:1.5 Other, describe: Efficiency AFUE or HSPF%93%SEER /EER 13 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 41529 12442 17,076 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Not required per mech. code Select Type X Passive x Heat Recover Ventilator (HRV) Capacity in cfms:Low: 82 High:192 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms:Low: High: Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms:6 " Flex Total ventilation (intermittent + continuous) rate in cfms: " metal duct 000000Builders Associaton of Minnesota version 101014 000000Builders Associaton of Minnesota version 101014 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 1936 1936 .64 .64 .36 .36 4.8 2.5 NR 3154 473 473 135 135 160 80