Loading...
HomeMy WebLinkAboutLA178047 17976 Evening Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: Secure door closed until deck is constructed with a separate permit. Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 03/13/2020dmathews (2)9-1/2 Versa-Lam (2)9-1/2 Versa-Lam (3)11-7/8 Versa-Lam 4' WSP 4' WSP 3.5 UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. (2)7-1/4 Versa-Lam (2)7-1/4 Versa-Lam Verify loads with girder truss specs, may require removal of top plates at bearing due to crushing. Temper (1)11-7/8 Versa-Lam4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP PFH PFH 3' CS-WSP 3' CS-WSP Girder -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). (2)9-1/2 Versa-Lam (2)7-1/4 Versa-Lam 4' WSP 4' WSP8' LIB 8' LIB 4' WSP 8' LIB4' WSP 4' WSP 3' WSP 8' LIB within 10' of be d r o o m FAN required for cantilever.BCI joist blocking23/32" min. plywood/OSBinto each flange.Nail with 8d nailsor rimboard closure.®F05Boise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-Acut, notch or drill flangesDO NOTDN01 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 .59 3.2 6.9 1230 1230 .41 .41 .59 NR 135 3804 571 571 240 375 170 85 000000Builders Associaton of Minnesota version 101014 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17976 Evening Lane Lakeville Name of Residential Contractor MN License Number Brandl Anderson Homes BC604388 THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply x Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometeror other system monitoring device) Location (or future location) of Fan: Attic Other Please Describe Here Below Entire Slab x Foundation Wall R-15 x R-5 where required Perimeter of Slab on Grade x Rim Joist (1st Floor)R-20 x x R10 Rigid Exterior, R10 Int closed cell Rim Joist (2nd Floor+)R-20 x x R10 Rigid Exterior, R10 Int closed cell Wall 19+5 x x R5 Exterior, R19 Batts Ceiling, flat R-49 x Ceiling, vaulted R-49 x Bay Windows or cantilevered areas R-38 x Floors over unconditioned area R-38+5 x x Describe other insulated areas Building envelope air tightness:Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.30 R-value R-8 MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic WaterHeater Cooling System x Not required per mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Lennox Lennox Powered Model ML193UH070 13ACXN024 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS:66,000 Capacity in Gallons:50 Output in Tons:2 Other, describe: Efficiency AFUE orHSPF%93%SEER /EER 13 Location of duct or system: Residential Load Calculation Heating Loss Heating Gain Cooling Load 61219 15436 20,716 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Not required per mech. code Select Type X Passive x Heat Recover Ventilator (HRV) Capacity in cfms:Low: 82 High:192 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms:Low: High: Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms:6 " Flex Total ventilation (intermittent + continuous) rate in cfms: " metal duct 17976 Evening Lane 03/03/2020 X KP