HomeMy WebLinkAboutLA178047 17976 Evening Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
Secure door closed until deck is
constructed with a separate permit.
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2015
MN Bldg
Code
03/13/2020dmathews
(2)9-1/2 Versa-Lam (2)9-1/2 Versa-Lam
(3)11-7/8 Versa-Lam
4' WSP
4' WSP
3.5
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
(2)7-1/4 Versa-Lam
(2)7-1/4 Versa-Lam
Verify loads with girder
truss specs, may require
removal of top plates at
bearing due to crushing.
Temper
(1)11-7/8 Versa-Lam4' WSP 4' WSP
4' WSP 4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
4' WSP
PFH PFH
3'
CS-WSP 3'
CS-WSP
Girder
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
(2)9-1/2 Versa-Lam
(2)7-1/4 Versa-Lam
4' WSP
4' WSP8' LIB
8' LIB
4' WSP
8' LIB4' WSP
4' WSP
3' WSP
8' LIB
within 10' of be
d
r
o
o
m
FAN
required for cantilever.BCI joist blocking23/32" min. plywood/OSBinto each flange.Nail with 8d nailsor rimboard closure.®F05Boise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-Acut, notch or drill flangesDO NOTDN01
40,000
X
X
40,000
40,000
3000
3000
3000
40,000
40,000 13.33
13.33 .59
3.2
6.9
1230
1230 .41
.41 .59
NR
135
3804
571
571
240
375
170
85
000000Builders Associaton of Minnesota version 101014
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Date Certificate Posted
Mailing Address of the Dwelling or Dwelling Unit City
17976 Evening Lane Lakeville
Name of Residential Contractor MN License Number
Brandl Anderson Homes BC604388
THERMAL ENVELOPE RADON CONTROL SYSTEM
Insulation Location
Total R-Value of all Types ofInsulationType: Check All That Apply x Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometeror other system monitoring device)
Location (or future location) of Fan:
Attic
Other Please Describe Here
Below Entire Slab x
Foundation Wall R-15 x R-5 where required
Perimeter of Slab on Grade x
Rim Joist (1st Floor)R-20 x x R10 Rigid Exterior, R10 Int closed cell
Rim Joist (2nd Floor+)R-20 x x R10 Rigid Exterior, R10 Int closed cell
Wall 19+5 x x R5 Exterior, R19 Batts
Ceiling, flat R-49 x
Ceiling, vaulted R-49 x
Bay Windows or cantilevered areas R-38 x
Floors over unconditioned area R-38+5 x x
Describe other insulated areas
Building envelope air tightness:Duct system air tightness:
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 X Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.30 R-value R-8
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic WaterHeater Cooling System x Not required per mech. code
Fuel Type Natural Gas Natural Gas Electric Passive
Manufacturer Lennox Lennox Powered
Model ML193UH070 13ACXN024 Interlocked with exhaust device.
Describe:
Rating or Size
Input in
BTUS:66,000 Capacity
in Gallons:50 Output
in Tons:2 Other, describe:
Efficiency AFUE orHSPF%93%SEER
/EER 13 Location of duct or system:
Residential Load Calculation Heating Loss Heating Gain Cooling Load
61219 15436 20,716 Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace):
Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
x Heat Recover Ventilator (HRV) Capacity in cfms:Low: 82 High:192 Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms:Low: High: Location of duct or system:
Balanced Ventilation capacity in cfms:
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms:6 " Flex
Total ventilation (intermittent + continuous) rate in cfms: " metal duct
17976 Evening Lane
03/03/2020 X
KP