HomeMy WebLinkAbout18330 Greenstone Way SurveyHOUSE ELEVATION DATA HOUSE TYPE = TWO STORY LOT TYPE = LOOKOUT BASEMENT WALL HEIGHT = 8.3 PROPOSED GARAGE FLOOR EL.= 1005.2 PROPOSED TOP OF BLOCK EL.= 1005.5 PROPOSED LOWEST FLOOR EL.= 997.5 GRADING QUANTITIES (CY) COMMON FILL -195 COMMON CUT 243 FOOTINGS/TRENCHES 60 HARD SURFACES 26 TOTAL FILL -195 TOTAL CUT 329 TOTAL (+/-) 134 HOUSE ELEVATION DATA HOUSE TYPE = TWO STORY LOT TYPE = LOOKOUT BASEMENT WALL HEIGHT = 8.3 PROPOSED GARAGE FLOOR EL.= 1005.2 PROPOSED TOP OF BLOCK EL.= 1005.5 PROPOSED LOWEST FLOOR EL.= 997.5 GRADING QUANTITIES (CY) COMMON FILL -195 COMMON CUT 243 FOOTINGS/TRENCHES 60 HARD SURFACES 26 TOTAL FILL -195 TOTAL CUT 329 TOTAL (+/-) 134 *Maintain 6" between bottom of siding and sod.*No structures in easements. The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with the landscape inspection. *Draintile connection required. EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION ENGINEERING REVIEWED Date:__________________03/05/2020 aoxborough Planning DepartmentApprovedDate:__________________03/16/2020 mwaite