Loading...
HomeMy WebLinkAboutLA178192 -5577 Upper 179th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"128GARAGE PLATE HEIGHT10' - 9 3/8"VINYL BOARD& BATTEN TYP.CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.3' - 6"SEE COLUMN DETAILSHEET A-50110" SMARTSIDE TRIM7:126" SMARTSIDE FRIEZE BOARD VINYL SIDING & CORNERS TYP.4" SMARTSIDE TRIM@ WINDOWS & DOORS FRONT TYP.7:1212812" ARCH12" ARCH3' - 0"VINYL SHAKES TYP.6" BUMPED OUT LOUVER W/ CORBELS 6" SMARTSIDE STORYBOARD127ADDRESS STONE THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:15 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-201OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN1/4" = 1'-0"A-2011FRONT ELEVATIONConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode03/23/2020dmathews 1278:128:127:128:1224" RETURN TYP.7:12ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.1281271287:128:128:121278:127:1224" RETURN TYP.8:128:128:128:128:128:127:127:12STANDARD ENERGY HEELS @ 8:1218" OVERHANGS & 12" RAKES TYP.7 ROOF VENTS REQUIRED STANDARD ENERGY HEELS @ 7:12 W/ 8:12 TO MATCH2 ROOF VENTS REQUIRED 7:122 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 7:127:121 ROOF VENT REQUIRED 1 ROOF VENT REQUIRED THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:17 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-202OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 7' - 10"0' - 2"20' - 6"12' - 0"1' - 4 1/2"9' - 3" M.O.1' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"*ALL DIMENSIONS ARETO EXTERIOR OFCONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.17' - 6"32' - 6"0' - 2"18' - 4"21' - 8"10' - 0"10' - 4"12' - 0"2' - 0"22' - 6"21' - 6"6' - 0"15' - 0"14' - 0"14' - 0"10' - 0"5' - 10"30' - 2"6' - 0"15' - 10"36' - 2"52' - 0"0' - 4"24' - 6"27' - 6"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYANCHOR BOLTS TO EACH SIDE OF BEARING POINTANCHOR BOLTS TO EACH SIDE OF BEARING POINTANCHOR BOLTS TO EACH SIDE OF BEARING POINT42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY52' - 0"15' - 2 3/4"4' - 2 3/4"4' - 2 3/4"6' - 5 3/4"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.11' - 9 1/4"11' - 10 3/4"8' - 1 1/4"10' - 2 3/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.2' - 2 3/4"19' - 11 3/4"17' - 9 1/2"STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE22' - 4"7' - 0"43' - 0"50' - 0"7' - 2"4' - 0 1/2"3' - 0"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY50' - 0"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:17 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-401OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN1/4" = 1'-0"A-4011FOUNDATION PLAN UP 16RUNEXCAVATEDMECHANICAL/STORAGE7' - 10"20' - 6"12' - 0"0' - 2"17' - 6"32' - 6"6' - 0"30' - 2"5' - 10"10' - 0"10' - 8 1/2"19' - 5 1/2"6' - 8 1/2"4' - 0"4' - 0"15' - 5 1/2"UNEXCAVATED14' - 0"14' - 0"15' - 0"52' - 0"52' - 0"SET ON3X SILL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7' - 6"7' - 6"7' - 0"7' - 0"7' - 0"7' - 0"0' - 4"*ALL DIMENSIONS ARE TOEXTERIOR OF CONCRETE ORSHEATHING, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB43' - 0" ( BRACED WALL LINE SPACING)7' - 0"0' - 4"4' - 0"6' - 7 1/4"2' - 2 3/4"49BEDROOM #5FAMILYROOMSUMPFLOOR GIRDER2146' - 0"2' - 0"9' - 7 3/4"4' - 1 1/4"6' - 7"3148" F.G. SHWR5'-6" VANITYBATH2x62x6FURNACEAIR EX.5' - 0"5' - 10"29' - 2"FULL BLACK RAIL W/ FULL HEIGHT SPINDLES 36' - 2"15' - 10"1110' - 4"12' - 0"2' - 0"22' - 6"21' - 6"6' - 0"24' - 6"27' - 6"18' - 4"21' - 8"CO DET.SMOKEDET.2-14" LVL FLUSH2-2x103-11 7/8" LSL W/3 TRIMMERS 4-2X64-2X65x5 PSL2-2x10 FLUSHANCHOR BOLTS TO EACH SIDE OF BEARING POINTANCHOR BOLTS TO EACH SIDE OF BEARING POINTANCHOR BOLTS TO EACH SIDE OF BEARING POINTANCHOR BOLTS TO EACH SIDE OF BEARING POINT2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"1' - 4 1/2"9' - 3" M.O.1' - 4 1/2"SMOKEDET.W. H.2-2x10F. D.112-2x104' - 2"6' - 8"7' - 6"2' - 6"8' - 4"3' - 0"22' - 4"50' - 0"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING10' - 0"40' - 0"28' - 4"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.2' - 8"24" CANT. ABOVE2-9 1/2" LSL W/ 2 TRIMMERS 2-2x10FLOOR GIRDER50' - 0"33' - 0" BRACED WALL LINE SPACINGB.W.P.8' - 0"18.5' OF WALLBRACINGREQUIREDB.W.P.8' - 0"18.5' OF WALLBRACINGREQUIREDTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:18 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-402OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN1/4" = 1'-0"A-4021LOWER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.FAN DN 3RDN 3RDN 16RUP 17R15' - 6"14' - 6"6' - 0"10' - 0"45' - 0"7' - 0"SINKDWPORCH2' - 0"17' - 6"20' - 6"12' - 0"2' - 3"16' - 0"2' - 3"1' - 6"9' - 0"1' - 6"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILING IF FLOOR ABOVEGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISE1416' - 0"30' - 0"6' - 0"17' - 0"14' - 0"14' - 0"GARAGE22' - 0"5BENCH W/DRAWERS4' - 0"3' - 6"8' - 8"5' - 0"24' - 6"27' - 6"52' - 0"FOYERDINING8' - 0"RAILING 15' - 5 1/2"4' - 0"4' - 0"6' - 6 1/2"5' - 0"5' - 0"1' - 8"28' - 4"SEE COLUMN DETAILSHEET A-501ATTICACCESS12722' - 6"2' - 0"19' - 6"32' - 6"5' - 0"1' - 0"5' - 0"9' - 0"4' - 0"6' - 9"4' - 0"7' - 3"2'-9" VANITY22' - 9"MECH CHASE112' - 7"9' - 5"DBL. FRAMED WALLFOR REFG. RECESS39"x73"5' - 5"1' - 4"3' - 7 1/4"11' - 7 3/4"4' - 10"0' - 7"6' - 1"1PANTRYCLOSET116OFFICE9' - 0"4' - 0"36" GASCOOKTOPW/ WOOD HOOD ABOVEWHITE CABINETS 12" FLUSH S.B.GAS LINE FOR FUTURE FIREPLACE 2' - 10"7' - 2"6' - 0"6' - 0"3' - 0"3' - 0"9' - 0"8' - 0"7' - 0"7' - 0"10' - 0"4' - 0"10' - 6 1/2"3' - 11 1/2"2' - 6"10' - 6"2' - 6"3' - 0"3' - 0"10881361' - 0"8' - 0"8' - 6"FLOORGIRDER810' - 0"12' - 0"6' - 0"28' - 0"KITCHENPOWDERR & SH.2-2x6 TRIMMERS2-2x6 TRIMMERS3-11 7/8" LSLFLUSH5x5 PSLGIRDER TRUSSGIRDER TRUSS4-2x6123-2x62-9 1/2" LSL DROPPED2-2x102-2x102-2x102-2x102-2x102-2x102-2x102-2x102-2x10 FLUSH2-2x10FLUSH2-11 7/8" LSLFLUSHB.W.P.3' - 0"B.W.P.8' - 0"B.W.P.2' - 8"B.W.P.10' - 0"B.W.P.4' - 0"B.W.P.6' - 0"PORTAL FRAME W/ HOLD-DOWNS PORTAL FRAME W/ HOLD-DOWNS B.W.P.6' - 0"B.W.P.7' - 0"METHOD G.B.6' - 0"R-38 INSULATION INFLOOR ABOVE SMOKEDET.2-2x103-2x65x5 PSL2-2x106'-10" ABOVE LANDING7RECYCLE2' - 6"8' - 4"MUD ROOM18' - 0"2-14" LVL FLUSHB.W.P.2' - 8"B.W.P.4' - 0"1099B.W.P.2' - 8"52' - 0"3' - 0"FULL BLACK RAIL W/ FULL HEIGHT SPINDLES TYP. OVEN /MICRO9' - 0 1/4"36" REF20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.52' - 0"GAS LINE1313TYP.0' - 4 1/2"GREAT ROOMMFG. ROOF TRUSSES@ 24" O.C.FUTURE GASHEATER1R & SH.R & SH.11LUS28-24-2x64-2x62-18" LVL FLUSH2-11 7/8" LSL 2-11 7/8" LSL 2-9 1/2" LSL W/ 2 TRIMMERS2-2x102-2x10 CONTINUOUS20' - 0" BRACED WALL LINE SPACING28' - 0" BRACED WALL LINE SPACING17' - 6" BRACED WALL LINE SPACING28' - 6" BRACED WALL LINE SPACING46' - 0" BRACED WALL LINE SPACINGB.W.P.7' - 0"B.W.P.3' - 0"B.W.P.3' - 0"METHOD G.B.6' - 0"52' - 0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:19 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-403OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESTemper if glasswithin 36" landing. DN 17R15' - 0"14' - 0"9' - 0"L.T.2' - 0"1' - 0"33' - 0"6' - 0"5' - 0"5' - 0"0' - 10"27' - 2"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.36' - 0"6' - 0"3332TILESHOWERSMOKEDET.7' VANITY3CLOSETOWNER'SBATHOWNER'SSUITE10BEDROOM #44102' LINEN5' VANITYBEDROOM #2BATHHALLBEDROOM #31' - 6"2' - 6"7' - 9"17' - 0"LAUNDRY2' - 8"12' - 9 1/2"312' - 6"4' - 0"4' - 0"15' - 5 1/2"3142' - 0"54" TALL WALLW/ 30" GLASSPANEL @ TOP533311438' - 0" ( BRACED WALL LINE SPACING)9' - 11"5' - 5 1/4"2' - 11 3/4"1' - 9"6' - 10"3' - 0"8' - 1"42' - 0"18' - 0"10' - 6"9' - 6"5' TUB/SHWR22' - 0"DBL. 2x4WALLSHELFBASE CABINET8' - 7"5' - 1"3' - 3"2' - 9"108' - 0"7' - 0"7' - 0"7' - 0"16' - 6 1/2"19' - 5 1/2"9' - 0"9' - 0"3' - 6"7' - 0"3' - 3"3' - 0"3' - 3"115' - 10 1/4"7' - 7 3/4"9' - 6"848' - 8 1/2"3' - 9 1/2"13' - 9"2' - 5"0' - 8"7' - 5 3/4"4' - 2 1/4"9' - 6"TYP.2' - 0"2-2x102-2x102-2x102-2x102-2x102-2x102-2x102-2x103-2x102-2x6 EA. SIDE2x6B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 0"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"B.W.P.2' - 8"ATTICACCESSFRAME FALSE WALL ON TRUSSES BELOW10'-10" ABOVE LANDINGCORNER SEAT2x638' - 0"FULL BLACK RAIL W/ FULL HEIGHT SPINDLES 2'x1' NICHEEQEQWASHERDRYERMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.12" BOX VAULT SHAMPOO SHELF37' - 0" ( BRACED WALL LINE SPACING)THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:20 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-404OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN1/4" = 1'-0"A-4041UPPER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Temper if glasswithin 60" of floor.FANFANFAN FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x4 TYP.1x3 CORNERS2x4 @ TOPSOFFITFRONTSIDETOP VIEW15" BOXED SMARTSIDE COLUMN4x4 POSTFRAMING1' - 3"1' - 3"1' - 3"1' - 6"2x2 3' - 0"1' - 3"18" SQUARE FRAMED BASE W/ CULTURED STONE ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:21 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-501OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN3/8" = 1'-0"A-5011METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5012TYP. COLUMNWINDOW SHECDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 2 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 36-42-3660 SH-PIC-SH 9' - 6" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 3 2418 AWN 2' - 0" 1' - 6" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN 2' - 0" 2' - 0" 6' - 10"5 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 2" 2' - 0" 5' - 8 7/8"6 WINDSOR NEXT DIMENSION 1 3048 SH 2' - 6" 4' - 0" 6' - 10"7 WINDSOR NEXT DIMENSION 1 3618 AWN FIXED 3' - 0" 1' - 6"6' - 10"8 WINDSOR NEXT DIMENSION 3 3660 SH 3' - 0" 5' - 0"9 WINDSOR NEXT DIMENSION 2 3672 SH 3' - 0" 6' - 0" 8' - 0"10 WINDSOR NEXT DIMENSION 2 3672-2W SH 6' - 0" 6' - 0" 8' - 0"11 WINDSOR NEXT DIMENSION 1 4836 PIC TEMP. 4' - 0" 3' - 0" 11' - 5"12 WINDSOR NEXT DIMENSION 1 4848 PIC 4' - 0" 4' - 0" 11' - 10"13 WINDSOR NEXT DIMENSION 3 P4260/AR24 T 3' - 6" 7' - 0" 8' - 0"14 WINDSOR NEXT DIMENSION 2 6048 SL 5' - 0" 4' - 0" 6' - 10"1/2" = 1'-0"A-5014GARAGE CEILINGROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA CEILING HEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 190 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 557 SF 8' - 2" .LOWER FLOOR MECHANICAL/ STORAGE UNFINISHED 160 SF 8' - 2" UNFINISHEDLOWER FLOOR BATH VINYL 56 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 99 SF 9' - 1 1/8" .MAIN FLOOR PORCH CONCRETE 105 SF 9' - 1 1/8" .MAIN FLOOR GARAGE UNFINISHED 716 SF 10' - 9 3/8"MAIN FLOOR PANTRY VINYL 16 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 24 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 57 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 75 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 183 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR POWDER WOOD 34 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 265 SF 9' - 1 1/8"UPPER FLOOR CLOSET CARPET 44 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 231 SF 8' - 1 1/8" 12" BOX VAULTUPPER FLOOR BEDROOM #4 CARPET 202 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 177 SF 8' - 1 1/8" .UPPER FLOOR HALL CARPET 104 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 184 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S BATH TILE 106 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 79 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 57 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE COUNT COMMENTS1 2/4 x 6/8 62 2/4 x 6/8 PKT 33 2/6 x 6/8 74 2/8 x 6/8 25 2/8 x 6/8 FIRE RATED 16 3/0 x 6/8 FULL VIEW 17 3/0 x 6/8 OPG. 18 3/0 x 6/8 W/ 12" D.S. SL'S 19 4/0 x 6/8 110 5/0 x 6/8 311 6/0 x 6/8 SLIDER 212 9' x 8' O.H. GARAGE DOOR 114 16' x 8' O.H. GARAGE DOOR 1 WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESVERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 10REV. 5TOTAL:3/10/2020 10:06:22 AMTHE BLOHM RESIDENCEL17, B4 - KNOB HILL5577 UPPER 179th STREET WESTLAKEVILLE, 55044A-502OTT096139911758788'-1 1/8"9'-1 1/8"8'-4"3.4.20 CB3.10.20 VL2.13.20 CB3452THE REAGAN3/8" = 1'-0"A-5021TYP. WALL SECTION1/2" = 1'-0"A-5022TYP. WALKOUT SECTION3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:1/2" = 1'-0"A-5023TYP. LOOKOUT SECTION1/2" = 1'-0"A-5024TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5025TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION Upper Level Member Name Results Current Solution Comments Owners Bathroom Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom # 2 Side Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Stair Landing Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Main Level Member Name Results Current Solution Comments Great Room Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Patio Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Flush Beam Passed 2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL Mudroom Office Flush Beam Passed 3 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Office Back WIndow Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Garage 9' OHD Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Garage 16' OHD Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Mudroom Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Foyer Front Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Front Porch Dropped Beam Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL (V) Stairs Flush Beam Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Foyer Stairs (H) Flush Beam Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Great Room Flush Beam Passed 2 piece(s) 1 3/4" x 18" 2.0E Microllam® LVL Stairs (H) Great Room Flush Beam Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Lower Level Member Name Results Current Solution Comments Stairs Flush Beam Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Family Room Window Passed 3 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Family Room Flush Beam Passed 2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL Squash Blocks Required Family Rom Patio Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom # 5 Window Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Mechanical Room Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 5577 Upper 179th St, Lakeville, MN JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 1 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1307 @ 0 1913 (1.50")Passed (68%)--1.0 D + 1.0 S (All Spans) Shear (lbs)266 @ 10 3/4"2872 Passed (9%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)735 @ 1' 1 1/2"3946 Passed (19%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.002 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"480 827 1307 None 2 - Trimmer - SPF 1.50"1.50"1.50"480 827 1307 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 -- 1 - Uniform (PSF)0 to 2' 3"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Owners Bathroom Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 2 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1888 @ 0 1913 (1.50")Passed (99%)--1.0 D + 1.0 S (All Spans) Shear (lbs)847 @ 10 3/4"2872 Passed (30%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1534 @ 1' 7 1/2"3946 Passed (39%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.007 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.011 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 3" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"694 1194 1888 None 2 - Trimmer - SPF 1.50"1.50"1.50"694 1194 1888 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 3"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom # 2 Side Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 3 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3788 @ 1 1/2"5738 (3.00")Passed (66%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2598 @ 1' 1/4"4308 Passed (60%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)5691 @ 3' 3"5919 Passed (96%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.061 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.096 @ 3' 3"0.313 Passed (L/779)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.98"1399 2389 3788 None 2 - Trimmer - SPF 3.00"3.00"1.98"1399 2389 3788 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.6 -- 1 - Uniform (PSF)0 to 6' 6"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Stair Landing Window 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 4 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1835 @ 11' 6"1913 (1.50")Passed (96%)--1.0 D + 1.0 L (Alt Spans) Shear (lbs)2531 @ 8' 7 3/4"2498 Passed (101%)1.00 1.0 D + 1.0 L (Adj Spans) Moment (Ft-lbs)1856 @ 9' 5 3/4"3431 Passed (54%)1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in)0.009 @ 9' 7 1/2"0.127 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in)0.016 @ 9' 7 13/16"0.191 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"588 579/-63 178 1345/- 63 None 2 - Trimmer - SPF 4.50"4.50"2.44"1599 1474 548 3621 None 3 - Trimmer - SPF 4.50"4.50"3.48"1888 2553 353 4794 None 4 - Trimmer - SPF 1.50"1.50"1.50"863 972/-63 244 2079/- 63 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 6"N/A 7.0 ---- 1 - Uniform (PSF)0 to 8' 9"8'15.0 40.0 -Floor - Upper 2 - Uniform (PSF)8' 9" to 11' 6"12'15.0 40.0 -Floor - Upper 3 - Uniform (PSF)0 to 11' 6"1'80.0 --Wall - Upper 4 - Point (lb)4' 3"N/A 459 -289 Bedroom # 4 WIndow 5 - Point (lb)9' 3"N/A 459 -289 Bedroom # 4 WIndow 6 - Uniform (PSF)0 to 4' 3"3'20.0 -35.0 Snow - Main 7 - Uniform (PSF)9' 3" to 11' 6"3'20.0 -35.0 Snow - Main 8 - Uniform (PSF)0 to 4' 3"1'100.0 --Wall - Gable 9 - Uniform (PSF)9' 3" to 11' 6"1'100.0 --Wall - Gable 10 - Point (lb)8' 9"N/A 434 920 - Linked from: Great Room FLR Girder, Support 2 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Great Room Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 5 / 25 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 6 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2278 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1400 @ 1' 1/4"2498 Passed (56%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3171 @ 4' 9"3431 Passed (92%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.071 @ 4' 9"0.308 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.181 @ 4' 9"0.463 Passed (L/612)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 7' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"1457 570 525 2552 None 2 - Trimmer - SPF 3.00"3.00"1.79"1457 570 525 2552 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 9' 6"N/A 7.0 ---- 1 - Uniform (PSF)0 to 9' 6"3'15.0 40.0 -Floor - Upper 2 - Uniform (PSF)0 to 9' 6"1'80.0 --Wall - Upper 3 - Point (lb)9"N/A 710 -446 Owners Suite Window 4 - Point (lb)8' 9"N/A 710 -446 Owners Suite Window 5 - Uniform (PSF)0 to 9"3'20.0 -35.0 Snow - Main 6 - Uniform (PSF)8' 9" to 9' 6"3'20.0 -35.0 Snow - Main 7 - Uniform (PSF)0 to 9"1'100.0 --Wall - Gable 8 - Uniform (PSF)8' 9" to 9' 6"1'100.0 --Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Dining Room Patio Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 7 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5618 @ 4"8181 (5.50")Passed (69%)--1.0 D + 1.0 L (All Spans) Shear (lbs)4254 @ 1' 7 1/2"9310 Passed (46%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)17493 @ 6' 11 7/8"24258 Passed (72%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.279 @ 6' 11 15/16"0.333 Passed (L/573)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.391 @ 6' 11 15/16"0.667 Passed (L/409)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 5.50"5.50"3.78"1605 4013 5618 Blocking 2 - Stud wall - SPF 5.50"5.50"3.70"1573 3927 5500 Blocking Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 14'N/A 14.3 -- 1 - Uniform (PSF)0 to 2' 6" (Front)15'15.0 40.0 Floor - Upper 2 - Uniform (PSF)2' 6" to 14' (Front)14'15.0 40.0 Floor - Upper Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Dining Room Flush Beam 2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 8 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)18578 @ 10' 2 3/4"25988 (5.50")Passed (71%)--1.0 D + 1.0 S (All Spans) Shear (lbs)8084 @ 11' 5 3/8"14817 Passed (55%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)-20047 @ 10' 2 3/4"27519 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.195 @ 16' 5 1/4"0.286 Passed (L/704)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.314 @ 16' 6 1/4"0.572 Passed (L/438)--1.0 D + 1.0 S (Alt Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 14' 11" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 11" o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"2.45"2133 188/-35 3323 5644/- 35 Blocking 2 - Column - PSL 5.50"5.50"3.93"7738 536 10840 19114 None 3 - Stud wall - SPF 5.50"5.50"3.12"2807 211/-20 4151 7169/- 20 Blocking Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 22'N/A 19.5 ---- 1 - Uniform (PSF)0 to 22' (Front)1'15.0 40.0 -Floor - Upper 2 - Uniform (PSF)0 to 22' (Front)1'80.0 --Wall - Upper 3 - Uniform (PSF)0 to 10' (Front)1'20.0 -35.0 Snow - Mono"s 4 - Uniform (PSF)10' to 22' (Front)2' 6"20.0 -35.0 Snow - Mono"s 5 - Point (lb)5' 3" (Front)N/A 480 -827 Linked from: Owners Bathroom Window, Support 1 6 - Point (lb)7' 3" (Front)N/A 480 -827 Linked from: Owners Bathroom Window, Support 2 7 - Uniform (PSF)0 to 5' 3" (Front)21'20.0 -35.0 Snow - Main 8 - Uniform (PSF)7' 3" to 22' (Front)21'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Office Flush Beam 3 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 9 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)5950 @ 1 1/2"7613 (3.00")Passed (78%)--1.0 D + 1.0 S (All Spans) [1] Shear (lbs)5408 @ 1' 1/2"7902 Passed (68%)1.15 1.0 D + 1.0 S (All Spans) [1] Moment (Ft-lbs)11331 @ 2' 3"11985 Passed (95%)1.15 1.0 D + 1.0 S (All Spans) [1] Live Load Defl. (in)0.114 @ 3' 13/16"0.208 Passed (L/656)--1.0 D + 1.0 S (All Spans) [1] Total Load Defl. (in)0.209 @ 3' 7/8"0.313 Passed (L/358)--1.0 D + 1.0 S (All Spans) [1] System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.34"2869 970 3081 6920 None 2 - Trimmer - SPF 3.00"3.00"1.50"1597 231 1753 3581 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.4 ---- 1 - Uniform (PSF)0 to 2' 3"11'15.0 40.0 -Floor - Upper 2 - Point (lb)2' 3"N/A 2807 211/-20 4151 Linked from: Mudroom Office Flush Beam, Support 3 3 - Uniform (PSF)0 to 2' 3"1'80.0 --Wall - Upper 4 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Main 5 - Uniform (PSF)0 to 6' 6"1'100.0 --Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Office Back WIndow 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 10 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3616 @ 1 1/2"7613 (3.00")Passed (48%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2697 @ 1' 2 7/8"9878 Passed (27%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)8368 @ 4' 10 1/2"18346 Passed (46%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.131 @ 4' 10 1/2"0.317 Passed (L/870)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.209 @ 4' 10 1/2"0.475 Passed (L/544)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 9' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 9" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1355 2261 3616 None 2 - Trimmer - SPF 3.00"3.00"1.50"1355 2261 3616 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 9' 9"N/A 13.0 -- 1 - Uniform (PSF)0 to 9' 9"13' 3"20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Garage 9' OHD 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 11 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 9" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None 2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 -- 1 - Uniform (PSF)0 to 16' 9"3'20.0 35.0 Snow - Main 2 - Uniform (PSF)0 to 16' 9"1'100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Garage 16' OHD 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 12 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1813 @ 0 1913 (1.50")Passed (95%)--1.0 D + 1.0 L (All Spans) Shear (lbs)759 @ 10 3/4"2498 Passed (30%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1397 @ 1' 6 1/2"3431 Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.009 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"502 1310 1812 None 2 - Trimmer - SPF 1.50"1.50"1.50"502 1310 1812 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 1"21' 3"15.0 40.0 Floor - Upper Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 13 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1259 @ 1 1/2"3825 (3.00")Passed (33%)--1.0 D + 1.0 L (All Spans) Shear (lbs)830 @ 1' 1/4"2498 Passed (33%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1734 @ 3'3431 Passed (51%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.027 @ 3'0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.037 @ 3'0.287 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"359 900 1259 None 2 - Trimmer - SPF 3.00"3.00"1.50"359 900 1259 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 6'N/A 7.0 -- 1 - Uniform (PSF)0 to 6'7' 6"15.0 40.0 Floor - Upper Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Foyer Front Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 14 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4795 @ 9'8181 (5.50")Passed (59%)--1.0 D + 0.75 L + 0.75 S (Adj Spans) Shear (lbs)1996 @ 10' 1/4"6872 Passed (29%)1.00 1.0 D + 1.0 L (Adj Spans) Moment (Ft-lbs)-4186 @ 9'10422 Passed (40%)1.00 1.0 D + 1.0 L (Adj Spans) Live Load Defl. (in)0.053 @ 13' 7 5/8"0.287 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.125 @ 13' 9 1/4"0.431 Passed (L/827)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 17' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 17' 9" o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"1.51"1357 643 549 2549 None 2 - Stud wall - SPF 5.50"5.50"3.22"2979 1456 965 5400 Blocking 3 - Trimmer - SPF 3.00"3.00"1.50"1180 545/-62 475 2200/- 62 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 17' 9"N/A 10.4 ---- 1 - Uniform (PSF)0 to 17' 9" (Front)3' 6"15.0 40.0 -Floor 2 - Uniform (PSF)0 to 17' 9" (Front)1'80.0 --Wall - Upper 3 - Point (lb)5' (Front)N/A 710 -446 Bedroom # 3 Window 4 - Point (lb)13' (Front)N/A 710 -446 Bedroom # 3 Window 5 - Uniform (PSF)0 to 5' (Front)3'20.0 -35.0 Snow - Main 6 - Uniform (PSF)13' to 17' 9" (Front)3'20.0 -35.0 Snow - Main 7 - Uniform (PSF)0 to 5' (Front)1'100.0 --Wall - Gable 8 - Uniform (PSF)13' to 17' 9" (Front)1'100.0 --Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Front Porch Dropped Beam 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 15 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)442 @ 3 1/2"1913 (1.50")Passed (23%)--1.0 D + 1.0 L (All Spans) Shear (lbs)267 @ 1' 3/4"2498 Passed (11%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)431 @ 2' 2 7/8"3431 Passed (13%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.003 @ 2' 2 7/8"0.097 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.004 @ 2' 2 7/8"0.195 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 3" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Hanger on 9 1/4" LSL beam 3.50"Hanger¹1.50"148 358 506 See note ¹ 2 - Stud wall - SPF 5.50"5.50"1.50"153 365 518 Blocking Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS28-2 2.00"N/A 6-10d 3-10d Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)3 1/2" to 4' 6 1/4"N/A 7.0 -- 1 - Uniform (PSF)0 to 4' 6 1/4" (Front)1'15.0 40.0 Floor - Upper 2 - Uniform (PSF)0 to 4' 6 1/4" (Front)3'15.0 40.0 Floor Stairs Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, (V) Stairs Flush Beam 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 16 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4088 @ 9' 8"8181 (5.50")Passed (50%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2875 @ 8' 6 5/8"8590 Passed (33%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)8657 @ 5' 1 7/16"15953 Passed (54%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.148 @ 5' 5/8"0.233 Passed (L/755)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.208 @ 5' 5/8"0.467 Passed (L/539)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 10' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 10' o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 5.50"5.50"1.92"834 2025 2859 Blocking 2 - Stud wall - SPF 5.50"5.50"2.75"1165 2923 4088 Blocking Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 10'N/A 13.0 -- 1 - Uniform (PSF)0 to 3' (Front)3' 3"15.0 40.0 Floor - Upper 2 - Uniform (PSF)3' to 10' (Front)15'15.0 40.0 Floor - Upper 3 - Point (lb)3' (Front)N/A 148 358 Linked from: (V) Stairs Flush Beam, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Foyer Stairs (H) Flush Beam 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 17 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)10256 @ 4"13956 (5.50")Passed (73%)--1.0 D + 1.0 S (All Spans) Shear (lbs)7665 @ 1' 11 1/2"13766 Passed (56%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)36397 @ 7' 9"44566 Passed (82%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.285 @ 7' 9"0.371 Passed (L/624)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.490 @ 7' 9"0.742 Passed (L/363)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 15' 6" o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"4.04"4289 310 5968 10567 Blocking 2 - Column - SPF 5.50"5.50"4.04"4289 310 5968 10567 Blocking Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 15' 6"N/A 18.4 ---- 1 - Uniform (PSF)0 to 15' 6" (Front)1'15.0 40.0 -Floor - Upper 2 - Uniform (PSF)0 to 15' 6" (Front)1'80.0 --Wall - Upper 3 - Uniform (PSF)0 to 15' 6" (Front)1'20.0 -35.0 Snow - Mono"s 4 - Uniform (PSF)0 to 15' 6" (Front)21'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Great Room Flush Beam 2 piece(s) 1 3/4" x 18" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 18 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)894 @ 1 1/2"3825 (3.00")Passed (23%)--1.0 D + 1.0 L (All Spans) Shear (lbs)438 @ 1' 1/4"2498 Passed (18%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)786 @ 2'3431 Passed (23%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.005 @ 2'0.094 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.007 @ 2'0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 3.00"3.00"1.50"254 640 894 Blocking 2 - Stud wall - SPF 3.00"3.00"1.50"254 640 894 Blocking Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4'N/A 7.0 -- 1 - Uniform (PSF)0 to 4' (Front)8'15.0 40.0 Floor - Upper Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Stairs (H) Great Room Flush Beam 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 19 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1937 @ 1 1/2"3825 (3.00")Passed (51%)--1.0 D + 1.0 L (All Spans) Shear (lbs)587 @ 1' 1/4"2498 Passed (23%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1090 @ 2' 4"3431 Passed (32%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.010 @ 2' 4"0.110 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.014 @ 2' 4"0.221 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 8" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 8" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 3.00"3.00"1.52"550 1387 1937 Blocking 2 - Stud wall - SPF 3.00"3.00"1.50"296 747 1043 Blocking Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 8"N/A 7.0 -- 1 - Uniform (PSF)0 to 4' 8" (Front)8'15.0 40.0 Floor - Upper 2 - Point (lb)0 (Front)N/A 254 640 Linked from: Stairs (H) Great Room Flush Beam, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Stairs Flush Beam 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 20 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)8164 @ 9' 10 1/2"11419 (3.00")Passed (71%)--1.0 D + 1.0 L (All Spans) Shear (lbs)7346 @ 8' 9 1/8"12884 Passed (57%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)20847 @ 6' 2 3/16"23930 Passed (87%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.213 @ 5' 5/8"0.325 Passed (L/551)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.367 @ 5' 7/16"0.488 Passed (L/318)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 7' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 10' o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.86"3147 3928 537 7612 None 2 - Trimmer - SPF 3.00"3.00"2.14"3308 4856 364 8528 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 10'N/A 19.5 ---- 1 - Uniform (PSF)0 to 3'1'15.0 40.0 -Floor - Main 2 - Uniform (PSF)3' to 8' 6"8'15.0 40.0 -Floor - Main 3 - Uniform (PSF)8' 6" to 10'10'15.0 40.0 -Floor - Main 4 - Point (lb)3'N/A 480 1280 -Cant Girder 5 - Point (lb)8' 6"N/A 463 997 - Linked from: Lower Level Great Room FLR Girder, Support 2 6 - Uniform (PSF)0 to 10'1'90.0 --Wall - Main 7 - Point (lb)2' 6"N/A 1599 1474 548 Linked from: Great Room Window, Support 2 8 - Point (lb)6' 6"N/A 1888 2553 353 Linked from: Great Room Window, Support 3 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Room Window 3 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 21 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5480 @ 13' 8"8181 (5.50")Passed (67%)--1.0 D + 1.0 L (All Spans) Shear (lbs)4206 @ 12' 4 1/2"9310 Passed (45%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)17364 @ 7' 1/8"24258 Passed (72%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.277 @ 7'0.333 Passed (L/578)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.388 @ 7'0.667 Passed (L/413)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 2" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' o/c based on loads applied, unless detailed otherwise. • Squash Blocks are assumed to carry all loads applied directly above them, bypassing the member being designed. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 5.50"5.50"3.60"3140 7840 10980 Blocking, Squash Blocks 2 - Stud wall - SPF 5.50"5.50"3.68"3140 7840 10980 Blocking, Squash Blocks Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 14'N/A 14.3 -- 1 - Uniform (PSF)0 to 2' 6" (Front)13'15.0 40.0 Floor - Upper 2 - Uniform (PSF)2' 6" to 14' (Front)14'15.0 40.0 Floor - Upper 3 - Point (lb)0 (Front)N/A 1605 4013 Linked from: Dining Room Flush Beam, Support 1 4 - Point (lb)14' (Front)N/A 1573 3927 Linked from: Dining Room Flush Beam, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Room Flush Beam 2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 22 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1989 @ 1 1/2"3825 (3.00")Passed (52%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1364 @ 1' 1/4"2498 Passed (55%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2988 @ 3' 3"3431 Passed (87%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.050 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.076 @ 3' 3"0.313 Passed (L/989)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.56"689 1300 1989 None 2 - Trimmer - SPF 3.00"3.00"1.56"689 1300 1989 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 -- 1 - Uniform (PSF)0 to 6' 6"3'15.0 40.0 Floor - Main 2 - Uniform (PSF)0 to 6' 6"1'90.0 -Wall - Main 3 - Uniform (PSF)0 to 6' 6"7'10.0 40.0 Floor - Deck Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Rom Patio Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 23 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)6354 @ 1 1/2"7613 (3.00")Passed (83%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)4886 @ 1' 1/2"7902 Passed (62%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)11151 @ 2' 8"11985 Passed (93%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.090 @ 2' 8"0.175 Passed (L/701)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.172 @ 2' 8"0.262 Passed (L/365)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 7" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.50"3041 2613 1805 7459 None 2 - Trimmer - SPF 3.00"3.00"1.97"2368 1950 1556 5874 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 10.4 ---- 1 - Uniform (PSF)0 to 5' 6"11'15.0 40.0 -Floor - Main 2 - Uniform (PSF)0 to 5' 6"1'90.0 --Wall - Main 3 - Point (lb)2' 8"N/A 2869 970 3081 Linked from: Office Back WIndow, Support 1 4 - Uniform (PSF)0 to 2' 8"11'15.0 40.0 -Floor - Upper 5 - Uniform (PSF)0 to 2' 8"1'80.0 --Wall - Upper 6 - Uniform (PSF)0 to 2' 8"3'20.0 -35.0 Snow - Main 7 - Uniform (PSF)0 to 2' 8"1'100.0 --Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Bedroom # 5 Window 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 24 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1601 @ 0 1913 (1.50")Passed (84%)--1.0 D + 1.0 L (All Spans) Shear (lbs)671 @ 10 3/4"2498 Passed (27%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1234 @ 1' 6 1/2"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.008 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"444 1156 1600 None 2 - Trimmer - SPF 1.50"1.50"1.50"444 1156 1600 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 1"18' 9"15.0 40.0 Floor - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by North House, Plan Date; 2/13/2020 Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Mechanical Room Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 3/3/2020 8:00:46 PM UTCAlex Schoenbauer, EWP Specialist Lyman Lumber (952) 470-4803 alex_schoenbauer@lymanlumber.com ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 File Name: 5577 Upper 179th St, Lakeville, MN Topaz - Reagan Blohm Residence 5577 Upper 179th St, Lakeville, MN 3/2/2020 Job # 24011 Page 25 / 25 03/10/2020XKP