Loading...
HomeMy WebLinkAboutLA178450 - 20598 Greenwood Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 03/23/2020 X KP COVER SHEET2015 MN Residential Code2015 MN Plumbing Code 2015 MN Fire Code2014 National Electrical Code2015 MN Energy Code2015 MN Fuel Gas Code2015 MN Mechanical Code 20598 Greenwood Ave Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 04/02/2020shutchins NOTES - SCHEDULES AND LEGENDS GENERAL NOTES FOUNDATION - BASEMENTBASEMENT FOUNDATION PLAN 1ST FLOOR PLAN1ST FLOOR PLAN 2ND FLOOR PLAN2ND FLOOR PLAN BUILDING SECTION BUILDING SECTION FRONT ELEVATION LEFT ELEVATION RIGHT ELEVATION REAR ELEVATION ROOF PLANROOF PLAN BASEMENT UTILITY PLANBASEMENT FOUNDATION PLAN 1ST FLOOR UTILITY PLAN1ST FLOOR PLAN 2ND FLOOR UTILITY PLAN2ND FLOOR PLAN STRUCTURAL PLAN - FOUNDATION BASEMENT (MN CODE)Bearing wall above STRUCTURAL PLAN - 1ST FLOOR (MN CODE) STRUCTURAL PLAN - 2ND FLOOR (MN CODE)Tempered Tempered 5-1/4" hold down at door AD 2.0 E SCALE: 1-1/2" = 1'-0" - VINYL SIDING - DAYLIGHT/WALKOUT FOUNDATION INSULATION DETAIL A SCALE: 1-1/2" = 1'-0"SIDING AND TRIM PER ELEVATION TYPICAL 1 STORY WALL SECTION w/ BASEMENT C SCALE: 1-1/2" = 1'-0" - ENG. SIDING - DAYLIGHT/WALKOUT FOUNDATION INSULATION DETAIL D SCALE: 1-1/2" = 1'-0" - VINYL SIDING - IN-GRADE BASEMENT FOUNDATION INSULATION DETAIL B SCALE: 1-1/2" = 1'-0" - ENG. SIDING - IN-GRADE BASEMENT FOUNDATION INSULATION DETAIL START TOP FRAMING HERE11 7/8" 4500 BCI @ 16" O.C.Connector SummaryPlotID Qty Manuf Product FlangeH1 6 Simpson IUS 1.81/11.88 NoneProductsPlotID Net Qty Product Length PliesJ1 8 11-7/8" BCI® 4500s-1.8 46' 0" 1J2 5 11-7/8" BCI® 4500s-1.8 42' 0" 1J3 3 11-7/8" BCI® 4500s-1.8 24' 0" 1J4 2 11-7/8" BCI® 4500s-1.8 20' 0" 1J5 1 11-7/8" BCI® 4500s-1.8 14' 0" 1J6 4 11-7/8" BCI® 4500s-1.8 8' 0" 1J7 4 11-7/8" BCI® 4500s-1.8 6' 0" 1J8 3 11-7/8" BCI® 4500s-1.8 4' 0" 1J9 11 11-7/8" BCI® 6000s-1.8 20' 0" 1BBO1 1 Beam by others 38' 0" 1BBO2 1 Beam by others 18' 0" 1BBO3 1 Beam by others 12' 0" 1R1 16 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0" 1K1 1 11-7/8" BCI® 4500s-1.8 72' 0" 1P1 6 Post by others 8' 0" 1STAIRWAYENDJOISTENDJOISTADD'L 4500 JOIST UNDER WALLADD'L JOIST UNDER ISLAND6000 SERIES4500 SERIES6000 SERIES4500 SERIESNOTE: OPTIONBED 6 / BATH 6PLUMBING DROPNOTE:Joist On Centers Can BeField Adjusted Up To 3"As Needed For Floor FramingUNEXCAVATEDDROP BEAMBY OTHERSDROP BEAMBY OTHERSDROP BEAMBY OTHERSSUNROOMOPTION4' EXTENSIONOPTIONKITCHEN ISLAND600# OFFSET BEARINGWALL CONDITION ABOVE3 CAROPTIONADDITIONAL JOISTS(2 PLY 11-7/8" BCI 4500s)REQUIRED WITHSTONE WALL ATMODERN FIRE PLACE.P1P1P1P1P1P1BBO2BBO1BBO3R1R1R1R1R1R1R1R1R1R1R1R1K1J3J3J3J4J1J1J8J4J8J7J7J5J8H1H1H1H1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1K1(6) J916" O.C.(5) J216" O.C.(6) J116" O.C.(5) J916" O.C.(2) J719.2" O.C.K1K1(4) J619.2" O.C.H138' 0"46' 0" 22' 11"6' 3 1/2" 11' 8"50' 0" 20' 0 1/2"8' 3 1/2"11' 9"3' 4 1/2"4' 0" 8' 0" 7' 5"11' 8"1' 4"1' 7 3/16"2' 6"SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:File: CONTINENTALBy: MLB / AESheet: 1 of 6REFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSFLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480BC FRAMEROTHER ELEVATIONSHR2H, PR1A, PR2G, NC2G, EC2G,CR2G, HR3S-10, CR2J, NC2JARE SIMILAR, SEE HOUSE PLANS.Scale: 1/4" = 1' - 0"Date: 10-08-15DWG: MAIN FLOORA PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900cut, notch or drill flangesDO NOTDN01Backer BlocksHeaderSingle joist as trimmer allowableif structurally adequateF17-BSee Boise literature forNail Boise Rimboardnail into each flange.to BCI joist with 8dBoise Rimboardvertical load capacity.®F07(stacked over wall below)Load bearing wall aboveSee Boise literature forvertical load capacity.BCI Joist Blocking®F06vertical load capacity.See Boise literature forF07-ABoise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-A START FRAMING HERE11 7/8" 4500 BCI @ 19.2" O.C.ProductsPlotID Net Qty Product Length PliesJ1 7 14" BCI® 4500s-1.8 28' 0" 1J2 4 14" BCI® 4500s-1.8 26' 0" 1J3 3 14" BCI® 4500s-1.8 24' 0" 1J4 14 14" BCI® 4500s-1.8 20' 0" 1J5 3 14" BCI® 4500s-1.8 16' 0" 1J6 2 14" BCI® 4500s-1.8 14' 0" 1J7 2 14" BCI® 4500s-1.8 12' 0" 1J8 6 14" BCI® 4500s-1.8 10' 0" 1J9 3 14" BCI® 4500s-1.8 8' 0" 1J10 1 14" BCI® 4500s-1.8 6' 0" 1J11 2 14" BCI® 4500s-1.8 4' 0" 1J12 6 14" BCI® 6000s-1.8 20' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 26' 0" 1B2 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0" 1B3-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0" 2B4-4 4 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0" 4B5-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 12' 0" 2B6 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 6' 0" 1BBO1 1 Beam by others 22' 0" 1BB02 1 Beam by others 10' 0" 1R1 14 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1K1 1 14" BCI® 4500s-1.8 40' 0" 1Connector SummaryPlotID Qty Manuf Product FlangeH1 45 Simpson IUS 1.81/14 NoneH2 3 Simpson IUS 2.37/14 NoneH3 1 Simpson HGUS7.25/10 NoneH4 1 Simpson HU 414 None(2) FLUSH LVL(4) FLUSH LVL(1) FLUSH LVLEND JOISTEND JOISTEND JOISTENDJOIST4500 SERIES @ 19.2" O.C.UNDER OWNERS BED6000 SERIES @ 19.2" O.C.UNDER OWNERS BATH6000 SERIES4500 SERIESSTAIRWAYOPEN TOBELOWROOFFRAMINGPORCH SIZE WILLVARY DEPENDINGON ELEVATIONNOTE: OPTIONMASTER BATH(S)PLUMBING DROPSVERIFY: ALLMECHANICALCHASE OPENINGREQUIREMENTSB5-2B4-4B1BB02B3-2B2BBO1B6R1R1R1R1R1R1R1R1R1R1R1R1R1K1J6J9J9J7J10J7J11J6J9J11H4H3H1H1H1H1H11X1X1X1X(7) J119.2" O.C.(6) J819.2" O.C.(4) J219.2" O.C.(10) J419.2" O.C.(4) J419.2" O.C.(3) J519.2" O.C.(3) J319.2" O.C.(6) J1219.2" O.C.K1K1K1K1H1H1H1H1H2H1H1H1H126' 8 1/2"11' 3 1/2"10' 0" 36' 0" 42' 0" 20' 0 1/2"6' 3 1/2" 11' 8"1' 6 3/16"1' 7 3/16"2' 0" 2' 0" SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:File: CONTINENTALBy: MLB / AEFLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480Sheet: 2 of 6BC FRAMERScale: 1/4" = 1' - 0"A PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900DWG: SECOND FLOORDate: 10-08-15Backer BlocksHeaderSingle joist as trimmer allowableif structurally adequateF17-Bcut, notch or drill flangesDO NOTDN01See Boise literature forNail Boise Rimboardnail into each flange.to BCI joist with 8dBoise Rimboardvertical load capacity.®F07(stacked over wall below)Load bearing wall aboveSee Boise literature forvertical load capacity.BCI Joist Blocking®F06vertical load capacity.See Boise literature forF07-ABoise I-Joist can be offset up to 3" to avoid vertical plumbing.Joist3" maxCLJoist3" maxCLOJ-AREFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSOTHER ELEVATIONSHR2H AND HR3S-10ARE SIMILAR, SEE HOUSE PLANS. Deduct Products from Base ElevationPlotID Net Qty Product Length PliesJ24 14" BCI® 4500s-1.8 26' 0"1Add Products for Elevation PR1APlotID Net Qty Product Length PliesJ1 4 14" BCI® 4500s-1.8 28' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1Add Products for Elevation PR1APlotID Qty Manuf Product FlangeH1 4 Simpson IUS 1.81/14 NoneEND JOISEND JONOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)(1) FLUSH LVLEXISTING JOISTUNCHANGEDPORCH SIZE WILLVARY DEPENDINGON ELEVATIONEXISTING JOISTUNCHANGEDB1(4) J119.2" O.C.H14' 0" 18' 0"20' 0"46' 0" Add Products for Elevation PR2GPlotID Qty Manuf Product FlangeH1 5 Simpson IUS 1.81/14 NoneDeduct Products from Base ElevationPlotID Net Qty Product Length PliesJ17 14" BCI® 4500s-1.8 28' 0"1J24 14" BCI® 4500s-1.8 26' 0"1Add Products for Elevation PR2GPlotID Net Qty Product Length PliesJ1 11 14" BCI® 4500s-1.8 30' 0" 1J2 1 14" BCI® 4500s-1.8 8' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1K1 1 14" BCI® 4500s-1.8 12' 0" 1NOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)END JOISEND JO(1) FLUSH LVLDROPPED 2X10'SAND POSTSBY OTHERSEXISTING JOISTUNCHANGEDBBOBBOB1K1J2(11) J119.2" O.C.K1H16' 0" 48' 0" 18' 0"20' 0"Add Products for Elevation NC2GPlotID Net Qty Product Length PliesJ1 5 14" BCI® 4500s-1.8 28' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1Add Products for Elevation NC2GPlotID Qty Manuf Product FlangeH1 4 Simpson IUS 1.81/14 NoneDeduct Products from Base ElevationPlotID Net Qty Product Length PliesJ11 14" BCI® 4500s-1.8 28' 0"1J24 14" BCI® 4500s-1.8 26' 0"1EXISTING JOISTUNCHANGEDNOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)(1) FLUSH LVLDROPPED 2X10'SAND POSTSBY OTHERSPORCH SIZE WILLVARY DEPENDINGON ELEVATIONEXISTING JOISTUNCHANGEDB1BBOH1(5) J119.2" O.C.1' 0"5' 0" 46' 0" 10' 11 1/2"7' 0"20' 0 1/2"Add Products for Elevation EC2GPlotID Qty Manuf Product FlangeH1 4 Simpson IUS 1.81/14 NoneDeduct Products from Base ElevationPlotID Net Qty Product Length PliesJ11 14" BCI® 4500s-1.8 28' 0"1J24 14" BCI® 4500s-1.8 26' 0"1Add Products for Elevation EC2GPlotID Net Qty Product Length PliesJ1 5 14" BCI® 4500s-1.8 28' 0" 1B1-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1DROPPED 2X10'SAND POSTSBY OTHERSEXISTING JOISTUNCHANGEDNOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)(2) FLUSH LVLEXISTING JOISTUNCHANGEDPORCH SIZE WILLVARY DEPENDINGON ELEVATIONBBOB1-2(5) J119.2" O.C.H11' 0"5' 0" 46' 0" 7' 0"20' 0 1/2"10' 11 1/2"Sheet: 3 of 6DWG: OPTIONSFile: CONTINENTALBy: MLB / AEDate: 10-08-15Scale: 1/4" = 1' - 0"BC FRAMERA PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:FLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480REFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSElevation PR1A Upper FloorElevation PR2G Upper FloorElevation EC2G Upper FloorElevation NC2G Upper Floor Add Products for Elevation CR2GPlotID Qty Manuf Product FlangeH1 4 Simpson IUS 1.81/14 NoneAdd Products for Elevation CR2GPlotID Net Qty Product Length PliesJ1 4 14" BCI® 4500s-1.8 28' 0" 1B1-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1Deduct Products from Base ElevationPlotID Net Qty Product Length PliesJ24 14" BCI® 4500s-1.8 26' 0"1EXISTING JOISTUNCHANGEDEND JOISTENDJOISTEND JOISTEND JOISTNOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)EXISTING JOISTUNCHANGEDPORCH SIZE WILLVARY DEPENDINGON ELEVATION(2) FLUSH LVLB1-2(4) J119.2" O.C.H120' 0"18' 0"46' 0" 4' 0" Add Connectors for Elev. CR2JPlotID Qty Manuf ProductH1 1 Simpson HUCQ 1.81/11-SDS1.75H2 5 Simpson IUS 1.81/14Add Products for Elev. CR2JPlotID Net Qty Product Length PliesJ1 4 14" BCI® 4500s-1.8 28' 0" 1J2 1 14" BCI® 4500s-1.8 16' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 2800 DF 16' 0" 1B2-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 10' 0" 2Deduct Products from Base ElevationPlotID Net Qty Product Length PliesJ2 4 14" BCI® 4500s-1.8 26' 0" 1J6 1 14" BCI® 4500s-1.8 14' 0" 1END JOISTENDJOISTNOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)END JOISTEND JOIST(2) FLUSH LVLEXISTING JOISTUNCHANGEDPORCH SIZE WILLVARY DEPENDINGON ELEVATIONEXISTING JOISTUNCHANGEDB1B2-2J2H1H2(4) J119.2" O.C.46' 0" 20' 6"4' 0" 17' 6"Add Products for Elev. NC2JPlotID Net Qty Product Length PliesJ1 7 14" BCI® 4500s-1.8 30' 0" 1J2 1 14" BCI® 4500s-1.8 18' 0" 1B1 1 1-3/4" x 14" VERSA-LAM® 2.0 2800 DF 18' 0" 1B2-2 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 10' 0" 2Add Connectors for Elev. NC2JPlotID Qty Manuf ProductH1 1 Simpson HUCQ 1.81/11-SDS1.75H2 6 Simpson IUS 1.81/14Deduct Products from Base ElevationPlotID Net Qty Product Length PliesJ1 2 14" BCI® 4500s-1.8 28' 0" 1J2 4 14" BCI® 4500s-1.8 26' 0" 1J6 1 14" BCI® 4500s-1.8 14' 0" 1EXISTING JOISTUNCHANGEDNOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)END JOISTENDROPPED 2X10'SAND POSTSBY OTHERS(2) FLUSH LVLEXISTING JOISTUNCHANGEDEND JOISTPORCH SIZE WILLVARY DEPENDINGON ELEVATIONRELOCATERIM & BLOCKINGFROM BASEBBOB2-2B1J2H1(7) J119.2" O.C.H26' 0" 11' 8"17' 6"2' 0" 46' 0" 8' 10"Add Products for 3 Car Garage OptionPlotID Net Qty Product Length PliesB1 1 Beam by others 20' 0" 1NOTE: STEEL OR LVLDROPPED BEAM(BY OTHERS)EXISTING JOISTUNCHANGEDEXISTING JOUNCHANGEND JOISTENDJOISTEND JOISTEND JOISTPORCH SIZE WILLVARY DEPENDINGON ELEVATIONDROP BEAMBY OTHERSNO BASEMATERIALCHANGESCONNECTIONBY OTHERSB15' 1"10' 0"20' 0" 2' 0" Sheet: 4 of 6DWG: OPTIONSFile: CONTINENTALBy: MLB / AEDate: 10-08-15Scale: 1/4" = 1' - 0"BC FRAMERA PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:FLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480REFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSElevation CR2G Upper FloorElevation CR2J Upper FloorElevation NC2J Upper Floor3 CAR GARAGE START OPTION JOIST11 7/8" 4500 BCI @ 19.2" O.C.Add Products for Sunroom OptionPlotID Net Qty Product Length PliesJ1 7 11-7/8" BCI® 4500s-1.8 12' 0" 1BBO1 1 Beam by others 12' 0" 1R1 2 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0" 1K1 1 11-7/8" BCI® 4500s-1.8 24' 0" 1EXISTING JOISTUNCHANGEDSTAIRWAYADD'L JOIST UNDER ISLAND6000 SERIES4500 SERIES6000 SERIES4500 SERIESADD'L 4500 JOIST UNDER WALLDROP BEAMBY OTHERSADDITIONAL JOISTS(2 PLY 11-7/8" BCI 4500s)REQUIRED WITHSTONE WALL ATMODERN FIRE PLACE.BBO1R1R1(7) J119.2" O.C.K1K1K1K1K110' 0" 12' 0"26' 0"56' 0" Add Products for 4' Gathering Extension OptionPlotID Net Qty Product Length PliesJ1 9 11-7/8" BCI® 4500s-1.8 6' 0" 1BBO2 1 Beam by others 16' 0" 1R1 1 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0" 1K1 1 11-7/8" BCI® 4500s-1.8 20' 0" 1EXISTING JOISTUNCHANGEDADD'L JOIST UNDER ISLANDADD'L JOIST UNDER ISLANDSTAIRWAY6000 SERIES4500 SERIESADD'L 4500 JOIST UNDER WALL6000 SERIES4500 SERIESDROP BEAMBY OTHERSADDITIONAL JOISTS(2 PLY 11-7/8" BCI 4500s)REQUIRED WITHSTONE WALL ATMODERN FIRE PLACE.BBO2R1R1(9) J119.2" O.C.K1K1K111' 2"15' 6 1/2"11' 3 1/2"4' 0" 1' 6 1/8"1' 7 3/16"1' 7 3/16"Add Products for 4' Gathering Extension OptionPlotID Net Qty Product Length PliesB1-3 3 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 16' 0" 3Add Products for 4' Extension OptionPlotID Qty Manuf Product FlangeH1 1 Simpson HHGU7.25X-SDS NoneH2 9 Simpson IUS 1.81/14 NoneDeduct Products from Base ElevationPlotID Net Qty Product Length PliesR11 1-1/8" x 14" BC RIM BOARD OSB 12' 0"1(4) FLUSH LVL(2) FLUSH LVLEXISTING JOISTUNCHANGED(3) LVL FLUSH BOTTOMOPEN TOBELOW6000 SERIES4500 SERIESB1-3H1H2 H2 H2 H2 H2 H2 H2 H2 H24' 0" 11' 2"15' 6 1/2"11' 3 1/2"Sheet: 5 of 6DWG: OPTIONSFile: CONTINENTALBy: MLB / AEDate: 10-08-15Scale: 1/4" = 1' - 0"BC FRAMERA PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:FLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480REFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSSunroom Main FloorUnused4 Ft Extension Main Floor4 Ft Extension Upper FloorALL OPTIONS AT REARAPPLY TO ALL ELEVATIONSSEE HOUSE PLANSALL OPTIONS AT REARAPPLY TO ALL ELEVATIONSSEE HOUSE PLANS START OPTION JOIST11 7/8" 4500 BCI @ 19.2" O.C.Add Products for Gathering Extension & SunroomPlotID Net Qty Product Length PliesJ1 7 11-7/8" BCI® 4500s-1.8 12' 0" 1J2 9 11-7/8" BCI® 4500s-1.8 6' 0" 1BBO3 1 Beam by others 28' 0" 1R1 2 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0" 1K1 1 11-7/8" BCI® 4500s-1.8 40' 0" 1P1 1 Post by others 8' 0" 1EXISTING JOISTUNCHANGEDADD'L JOIST UNDER ISLANDSTAIRWAYDROP BEAMBY OTHERS4500 SERIESADD'L 4500 JOIST UNDER WALL6000 SERIES4500 SERIES6000 SERIESADDITIONAL JOISTS(2 PLY 11-7/8" BCI 4500s)REQUIRED WITHSTONE WALL ATMODERN FIRE PLACE.P1BBO3R1R1R1(7) J119.2" O.C.(9) J219.2" O.C.K1K1K1K1K1K111' 2"14' 10"12' 0"4' 0" 6' 0" Add Products for Gathering Extension & SunroomPlotID Net Qty Product Length PliesB1-3 3 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 16' 0" 3Add Products for 4' Extension & SunroomPlotID Qty Manuf Product FlangeH1 1 Simpson HHGU7.25X-SDS NoneH2 9 Simpson IUS 1.81/14 NoneDeduct Products from Base ElevationPlotID Net Qty Product Length PliesR11 1-1/8" x 14" BC RIM BOARD OSB 12' 0"1STAIRWAYOPEN TOBELOW6000 SERIES4500 SERIESEXISTING JOISTUNCHANGED(4) FLUSH LVL(2) FLUSH LVL(3) LVL FLUSH BOTTOMB1-3H2 H2 H2 H2 H2 H2 H2 H2 H2H111' 2"4' 0" 14' 10"6' 0" 12' 0"Add Products for Owners Retreat OptionPlotID Net Qty Product Length PliesJ1 7 14" BCI® 4500s-1.8 20' 0" 1R1 2 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1Deduct Products from Base ElevationPlotID Net Qty Product Length PliesJ86 14" BCI® 4500s-1.8 10' 0"1B21 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0"1B4-44 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 20' 0"4B5-22 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 12' 0"2Deduct Connectors from BasePlotID Qty Manuf Product FlangeH112 Simpson IUS 1.81/14NoneH31 Simpson HGUS7.25/10NoneH41 Simpson HU 414NoneAdd Connectors for OptionPlotID Qty Manuf Product FlangeH1 7 Simpson IUS 1.81/14 NoneSTAIRWAYEXISTING JOISTUNCHANGED4500 SERIES6000 SERIES4500 SERIES @ 19.2" O.C.UNDER OWNERS BED6000 SERIES @ 19.2" O.C.UNDER OWNERS BATHR1R1H1H1H1H1H1H1H1(7) J119.2" O.C.Sheet: 6 of 6DWG: OPTIONSFile: CONTINENTALBy: MLB / AEDate: 10-08-15Scale: 1/4" = 1' - 0"BC FRAMERA PULTE HOMES MODELby:Boise CascadeLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.6-12-18AERevisions:BY:FLOOR LOADS USED IN DESIGN:LIVE LOAD: 40 PSFDEAD LOAD: 10/20 PSFFLOOR LOAD ACCOUNTSFOR TILE LOADSDESIGN = L/480REFER TO STRUCTURALDOCUMENTS FOR MORE DETAILSALL OPTIONS AT REARAPPLY TO ALL ELEVATIONSSEE HOUSE PLANSALL OPTIONS AT REARAPPLY TO ALL ELEVATIONSSEE HOUSE PLANSSunroom & 4' Extension Main FloorSunroom & 4' Extension Upper FloorOwners Retreat Upper FloorUnused 6"D(see table below)D(see table below)Minimum spacing = 2x greatest dimension of largest hole (knockouts exempt)Do not cut holes larger than 11/2" round in cantilevers.A 11/2" round hole may be cut anywhere in the web. Provide at least 3" of clearance from other holes.6"6"6"6"No holes (except knockouts) allowed in bearing zones2x_ ledger.Roof Span2'-6"2'-0"BCI® Joist blockingWood Structural Panel ClosureDrywall Ceiling or Wood Structural Panel SoffitBack Span Maximum1/3 Back Span Not to exceed 4'-0"Wood backer blockSee page 6 of Western Specifier Guide31/2" min. bearing Back Span Maximum 1/3 Back Span not to exceed 4'-0" BCI® Joist blocking 2x8 minimum Minimum 11/2 Times Cantilever Length Section View 2x Closure See Note 31/3 Depth1/3 Depth1/3 Depth1/3 Span1/3 SpanEnd BearingIntermediate Bearing18'14'Hangers not shown for clarity DO NOT bevel cut VERSA-LAM® beyond inside face of wall without approval from Boise Cascade EWP Engineering or BC CALC® software analysis.Engineered Wood Products