Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA178600 - 19176 Impala Ave Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received _______ _______ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov 19176 Impala Avenue Lakeville MN 55044 SF Residence w/Finished Basement Washburn N/A $ 363,474 4/3/20 9/1/20 2 5 Summerlyn-8th Addition ■ ■ Deb.Bosley@Lennar.com Lennar Homes 001413 952-249-3000 16305 36th Avenue North Plymouth MN 55446 Elander Mechanical Inc. 59244 952-445-4692 612-363-4276 591 Citation Drive Shakopee MN 55379 Elander Mechanical Inc. 952-445-4692 612-363-4276 591 Citation Drive Shakopee MN 55379 MB 3546 DLR Construction 651-248-8396 Deb Bosley 3/20/20 ✘ ✘ ✘ RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400 952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/07/2020dmathews UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.4.53.5 ····················5INFO APPLIES SYMMETRICALLY ACROSS DETAIL.FASTEN BOTTOM PLATE w/(3) 16d NAILS EVERY 16"LSL/LVL FLUSHBEAM BYSUPPLIER8’−0" SINGLE SHEET TYP.USP PAU66 POST BASE w/58"Ø x 8" USP WEDGE BOLTSCREW−IN ANCHOR6x6 POSTCROSS HATCH AREAS INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDES OF POSTS & 34"OR THICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO INTERIOR SIDES OF POSTS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED)716" OR THICKER PLYWOOD OROSB SHEATHING APPLIED TOEXTERIOR SIDES OF POSTSFLUSH BEAMPROVIDE LAYER/S OFPLYWOOD/OSB TO FLUSHOUT BEAM w/ POSTCENTER 6x6 POSTw/ STANDARDPOST BASE & CAP34" OR THICKER PLYWOOD OROSB SHEATHING APPLIED TOINTERIOR SIDES OF POSTS(INSTALL PRIOR TO JOISTS)NAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED& TO PLATES / BLOCKING @ 3" O.C.)USP LSTA24 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN TOP PLATE TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD &(1) 2x6 FULL HEIGHT STUDEACH END OF HEADERLOCATE PANEL JOINT WITHIN 2’−0"FROM CENTER OF WALL HEIGHT ASREQ’D (2x SOLID BLOCKINGREQUIRED AT SHEATHING JOINT)(2) 2x6 BEARINGSTUDS MIN.LENGTH OF CONTINUOUS HEADERFASTEN KING STUD TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.CENTER BEARINGSTUDS BY SUPPLIERFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSLARGER HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILING PATTERN1’−0"±1’−0"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN. 3" WIDTH & MIN. 912" DEPTH REQ’D)FOUNDATION WALL BELOW1’−0"±1’−0"±S4FRAMING DETAILPORCH END WALL w/ LOOKOUTOR WALKOUT FOUNDATION(OPTION−1)3INFO APPLIES SYMMETRICALLY ACROSS DETAIL.FASTEN BOTTOM PLATE w/(3) 16d NAILS EVERY 16"LSL/LVL FLUSHBEAM BYSUPPLIERUSP MSTC28 STRAPCONNECTION BETWEENSTUDS & FLUSH BEAMNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED& TO PLATES / BLOCKING @ 3" O.C.)USP LSTA24 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN TOP PLATE TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD &(1) 2x6 FULL HEIGHT STUDEACH END OF HEADERLOCATE PANEL JOINT WITHIN 2’−0"FROM CENTER OF WALL HEIGHT ASREQ’D (2x SOLID BLOCKINGREQUIRED AT SHEATHING JOINT)(2) 2x6 BEARINGSTUDS MIN.LENGTH OF CONTINUOUS HEADERFASTEN KING STUD TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.CENTER BEARINGSTUDS BY SUPPLIERFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSLARGER HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILING PATTERN1’−0"±1’−0"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN. 3" WIDTH & MIN. 912" DEPTH REQ’D)FOUNDATION WALL BELOW113’−0"±58" Ø THRU BOLTSOR 10" LONG LAGSCREWS ATLOCATIONS SHOWN(MAY SUPSTITUTE(2) 38" x 8" GRK RSSFOR EACH 58"BOLT/LAG SCREW)116x6 POSTS TYP. 6x6 DIAGONALMEMBERSUSP PAU66 POST BASE w/58"Ø x 8" USP WEDGE BOLTSCREW−IN ANCHORUSP LFTA6 TWIST STRAPCONNECTION BETWEENFLUSH BEAM & POSTPAIR OF USP PB66−6TZ POSTPOST CAPS AT ALL POSTSS4FRAMING DETAILPORCH END WALL w/ LOOKOUTOR WALKOUT FOUNDATION(OPTION−2)4INFO APPLIES SYMMETRICALLY ACROSS DETAIL.USP MSTC28 STRAPCONNECTION BETWEENSTUDS & FLUSH BEAM5PFHPFH556663.253.25TemperVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing. ····················33-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). PAGE DESCRIPTION:PAGE NO.: PLAN NO. FIREPLACEFIREPLACESFIREPLACES REVISIONS ······Floor to be blockedand sealed forcontinuous vaporbarrier requirement.Secure door closed until deck isconstructed with a separate permit.Temper Weyerhaeuserprepared theseplans for the specificationof Trus Joistproductsbased on project information provided to us. This service issolelyintendedfor product application assurance; and, is not intendedtocircumventthe need for a design professional as determined by thebuilding codes.The designer of record and/or builder/framer isresponsible to assure thesedrawings are compatible with the overall project.Copyright 2009 Weyerhaeuser NR Company. All rights reserved.Anyunauthorized copying of reproductionwill constitute an infringement of copyright.LENNAR - MN4014 WASHBURNALL ELEVATIONSR12-152106 4014 B Sheet 1 of 3 Structural Framer's Pocket Guide. Access with your Smart Phone. http://woodbywy.com/document/tj-9001/ Have a damaged joist or beam? File an electronic damage report for prompt service from your regionaltechnical office. Scan the QR Code with your smartphone or go to: www.damagereport.w oodbywy.com Specification Teamservice.request@weyerhaeuser.com(888)453-8358 . . . . . . . .www.woodbywy.comDrawn By:ALAN GOriginal Date:8/13/12Rev.ByDateJLH9-20-18CommentsAdjusted garage expansion option.Architectural Drawings Prepared By:LENNAR - MNStructural Drawings Prepared By:N/A12/16/13N/ADrive nails at an angle to minimize splitting of plate One 10d (3") box nail each side of member at bearing, 112" minimum from end See framing plan (if applicable) or iLevel® Framer's Pocket Guide for minimum end and intermediate bearing lengths. TJI® JOIST NAILING REQUIREMENTS at BEARING 13 4" minimum bearing at end support; 312" minimum at intermediate support TJI® Joist to Bearing Plate Shear transfer: Connections equivalent to floor panel nailing schedule One 8d (212") box nail each side. Drive nails at an angle at least 112" from end. Squash Blocks to TJI® Joist (Load bearing wall above) One 10d (3") box nail into each flange 10'-0"11'-6"1'-0"1'-0"1'-0"1'-0"9'-0"9'-0"6'-0"3'-0"1'-0"1'-0"1'-0"360 1'-0" 12'-0" 17" 13" 15'-6" 15'-6" SQUARE OR RECTANGULAR HOLE SIZE Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support 16'-0" 15'-6" 21'-0" 20'-6" 18'-0" 17" 17'-0" DO NOT cut, notch or drill holes in headers except as indicated in illustrations and tables. For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be located at the center of the joist span provided no other holes occur in the joist. Distances are based on the maximum uniform loads shown in current Trus Joist® product guides. For other load conditions or hole configurations contact your Weyerhaeuserrepresentative. 15"8"10"6"4"12"17"15"12"10"8"6"4" 16'-0" 15'-6" Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole. Knockouts are located in web at approximately 12" on-center; they do not affect hole placement. 1'-0" 1'-0" 1'-0" 1'-0" Rectangular holes based on measurement of longest side. 18" 20"1'-0"560 560 360 360 1'-0" 1'-0" 1'-0" 1'-0"1'-6" 1'-0" 2'-0" 3'-0" 3'-0" 6'-0" 6'-0" 12'-0"5'-6" 16'-6" 11'-0" 15'-0" 10'-0" 6'-0" 9'-0" 6'-0" 3'-0" 1'-6" 4'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16'-6" 18'-0" 16'-6" 14'-0"8'-6" 7'-0" 9'-0" 11'-6"16'-6" 12'-6" 14'-6" 19'-6"17'-6' 19'-0" 20'-0" 19'-6" 10'-0" 17" 11'-0" 13" 10'-6" ROUND HOLE SIZE Table B - Intermediate or Cantilever Support 10'-6" 9'-6" 15'-0" 13'-6" 4'-0"8'-0"2'-6"230 3'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 4'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16" 14" 230 560 360 1'-0" 1'-0" 1'-0" 230 560 210 360 1'-0" 1'-0" 1'-0" 1'-0" 1178"1'-0"230 360 110 210 560 2'-0" 1'-0" 1'-6" 360 210 110 3'-0" 1'-0" 1'-0" 9'-0"5'-0"1'-0"2'-6" 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" 3'-0" 1'-0" 1'-0" 1'-6" 2'-0" 1'-0" 5'-6" 5'-6" 3'-0" 11'-0" 10'-0" 4'-0" 7'-0" 6'-6" 6'-6" 10'-0" 13'-6" 12'-6" 5'-6" 9'-6" 3'-0" 8'-6" 5'-6" 2'-6"5'-0" 4'-0" 1'-0" 4'-6" 7'-0" 2'-0" 8'-0" 5'-6" 2'-0" 1'-6" 4'-6" 4'-0" 9'-0" 9'-6" 11'-0" 4'-6" 12'-0" 8'-0" 9'-0" 8'-0" 6" 3" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-6" 2'-6" DEPTH 912" TJI® 210 110 2" 2'-0" 1'-6" 18" 20" 1'-0"360 560 560 360 1'-0" 1'-0" 1'-0" 560 1'-0" 4" 4" 3'-6" 3'-0" 612" 7'-6" 7'-6" 878"11" 1'-0"2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 8"10" 1'-0" 10'-0"5'-0" 11'-0"5'-0" 1'-0" 2'-0" 7'-0" 7'-0" 3'-0" 12" 6'-6" 15" 7'-6"3'-0"2'-6"4'-6" 4'-6" 2'-0" 1'-6" 3'-6" 2'-6" 1'-0" 1'-0" 1'-0" 3'-0" 1'-0" 1'-0" 2'-0" 4'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 12'-6"6'-0"2'-0"10'-0" 10'-6" 13'-6" 12'-0" 10'-6" 14'-6" 13'-0" 1'-0" 3'-6" 2'-0" 5'-0" 9'-0" 7'-6" 1'-0" 5'-0" 4'-0" 2'-6"6'-0" 4'-6" 10'-0" 9'-0" 13'-0" 16'-0" 14'-6" 13'-0" 12'-6" 15'-0" 14'-0" 9'-6" 12'-0" 11'-0" 10'-0" 10'-0" 8'-0"3'-6" 5'-0" 1'-0" 6'-0" 9'-6" 5'-0" 10'-6" 5'-6" 3'-0" 2'-6" 8'-0" 7'-6" 6'-6" 12'-0"9'-0" 9'-0" 1'-0" 6" 1'-6" 1'-0" 1'-0" 3" 1'-0" 3'-0" 2'-6" 2'-0" 1'-6" 2" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 4" 4'-0" 3'-6" 4"612" 7'-0" 6'-6" 11"878" 10'-0" 12'-0" 11'-6" 11'-0"10'-0"5'-0" 6'-6" 4'-0" 2'-6" 11'-0" 9'-6" 8'-0" 1'-0" 8" 1'-6" 10" 13'-6" 14'-6" 14'-6" 14'-0" 12'-6' 11'-0" 15"12" 13" 11'-0" 10'-6" SQUARE OR RECTANGULAR HOLE SIZE 13" 6'-0" 6'-6" ROUND HOLE SIZE Minimum distance from edge of hole to inside face of nearest end support 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 2'-0" 1'-6" 1'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0"1'-0"560 16" 14" 1'-0"360 210 230 560 1'-0" 1'-0" 1'-0" 210 230 110 1'-0" 1'-0" 1'-0" 1178" 912" 110 230 360 210 1'-0" 1'-0" 1'-0" 1'-0" 110 230 360 210 1'-0" 1'-0" 1'-6" 1'-0" 8'-0"1'-6"3'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0"1'-0" 1'-0" 8'-0"5'-6" 1'-6" 2'-0" 6'-0" 3'-6" 4'-0" 9'-0" 3'-0" 3'-6" 2'-6" 6'-0" 6'-6" 5'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 2'-6" 2'-0" 1'-6" 2'-0" 2'-6" 3'-0" 2'-0" 4'-0" 3'-6" 2'-6" 3'-0" 5'-0" 6'-0" 7'-0" 5'-6" Table A - End Support 3"DEPTH TJI® 2"4"878"11" 1'-6" 2'-0" 1'-0" 2'-6" 2'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 5'-0"3'-6"8'-0" 2'-6"1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 3'-6" 1'-0" 1'-0" 1'-0" 2'-0" 2'-0" 1'-6" 9'-6"8'-0" 9'-0" 8'-0" 10'-0" 7'-0" 6'-6" 9'-0" 9'-0" 8'-6" 8'-0" 7'-0" 6'-0" 6'-6" 1'-6" 2'-6" 2'-0" 2'-0" 2'-6" 4'-0" 3'-0" 3'-0" 3'-6" 3'-0" 2'-6" 2'-6"3'-6" 5'-0" 4'-6" 4'-0" 7'-6" 7'-0" 6'-6" 6'-0" 3"2"4"11"878" Also see detail B2 612" 5'-0" 5'-0" 5'-6" 6'-0" 2'-6" 3'-0" 4'-6" 2'-6" 1'-0" 1'-6" 1'-0" 2'-6" 1'-0" 1'-0" 2'-6" 5'-0" 1'-0" 1'-0" 612" 4'-6" 5'-0" 5'-0" 5'-6" 5'-0" 5'-6" 6'-6" 4'-6" 3'-6" 4'-0" 4'-0" 6'-6" 3'-0" 2'-6" 5'-6" 7'-0" 5'-0" 4'-0" 3'-0" 3'-6" 5'-0" 2'-6" 1'-6" 2'-0" 1'-0" 3'-0" 1'-0" 1'-0" 3'-0" 5'-6" 1'-0" 1'-0" 5'-6" 5'-6" 6'-6" 4'-6" 4'-0" 4'-6" 5'-0" 7'-0" 3'-6" 3'-6" 6'-6" 7'-6" 6'-0" 5'-0" 5"5"7"7" 1'-0" 1'-0" 1'-0" 5" 4'-0" 4'-6" 2'-6" 3'-0" 6'-6" 5'-6" 1'-0" 5'-6" 3'-6" 3'-6" 3'-6" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 5'-0" 7" 4'-0" 3'-0" 2'-0" 3'-6" 4'-0" 3'-6" 1'-0" 6'-6" 6'-0" 5'-6" 7'-6" 2'-6" 8'-6" 5'-0" 7"5" 5'-6" 6'-6" 3'-6" 2'-6" 5'-6" 4'-0" 4'-0" 2'-0" 7'-0" 5'-6" 5'-0" 7'-0" 2'-6" 8'-0" 7'-6" 4'-6" 4'-0" 6'-0" 8'-0" 11'-0" 6'-0" 9'-6" 8'-6" 10'-0" 11'-0" 5'-6" 7'-6" 8'-6" 10'-0" 6'-0" 7'-0" 7'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 7" 1'-0" 1'-0" 1'-0" 1'-0" 5"7" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 4'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 7"5" 1'-0" 1'-0" 3'-6" 1'-6"6'-6" 4'-0" 6'-0" 8'-6" 7" 1.3E TimberStrand® LSL allowed hole zone dd Microllam® LVL andParallam® PSL allowed hole zone middle 13 span 1.3E TimberStrand®LSL hole zone Microllam® LVL and Parallam®PSL hole zone 2 x diameter of the largest hole (minimum) d 13 depth 1" 2" 134" MAXIMUM ROUND HOLE SIZE HEADER DEPTH 438" 714" to 20" 512" See illustration for Allowed Hole Zone Other Trus Joist® Trus Joist® Headers and Beams 1.55E TimberStrand®LSL Headers and Beams ALLOWABLE HOLES - Headers and Beams 13 depth 2 x diameter of the largest hole (minimum) 2 x diameter of the largest hole (minimum)Allowed hole zone 8"8" See illustration for allowed hole zone 1114"-11 78" 14" to 16" 914"-912" HEADER DEPTH MAXIMUM ROUND HOLE SIZE 358" 458" 3" No holes in headers or beams in plank orientation. Round holes only General Notes General Notes No holes in headers or beams in plank orientation. Allowed hole zone suitable for uniformly loaded headers and beams only. Round holes only No holes in cantilevers. BEAM ATTACHMENT at BEARING This sheet is intended as a supplement to the Trus Joist® Framer's Pocket Guide, which should be referenced for additional information. THINK SAFETY-READ INSTALLATION INFORMATION BEFORE PROCEEDING Allowable Load 400 475 Allowable load determined in accordance with AC 124. Corrosion-resistant fasteners required for wet-service applications. 114" TimberStrand® LSL rim board EXTERIOR DECK ATTACHMENT Structural exterior sheathing See fastener table below. Maintain 2" distance (minimum) from edge of ledger to fastener. 8" diameter maximum hole for 1178" - 16" deep blocking panels; 6" diameter maximum for TJI® blocking panels 912" deep or shorter than 12" long. Do not cut flanges. GENERAL TRUS JOIST PRODUCT ASSEMBLY DETAILS E1 E1W Web stiffeners required each side at E1W Backer block: Install tight to top flange (tight to bottom flange with face mount hangers). Attach with ten 10d (3") box nails, clinched when possible. H2 Backer block both sides of web with single TJI® joist Filler block: Attach with ten 10d (3") box nails, clinched. Use ten 16d (312") box nails from each side with 312" TJI® joist flange widths. Use fifteen nails withTJI® joist depths greater than 16". 12" lag bolt LA 38" lag bolt Fastener Flashing Treated 2x_ ledger 400 N.A. 118" Trus Joist® rim board Web stiffener each side. See sizes below. W Tight fit WEB STIFFENER ATTACHMENT Gap: 18" minimum 234" maximum Three 8d (212") box nails, clinched (Three 16d (312") box nails at 312"TJI® joist flange widths 112" 112" Load bearing or shear wall above (must stack over wall below) TJI® blocking panel Web stiffeners required each side at B1W and B2W B2 B1 B1W B2W 116" 2x4 minimum squash blocks Use 2x4 minimum squash blocks to transfer load around TJI® joistCS Load from above 2x4 minimum squash blocks 116" With top flange hangers, backer block required only for downward loads exceeding 250 lbs or for uplift conditions. NOTE: STUCTURAL DOCUMENTS FOR THIS PROJECT PER THE DESIGN PROFESSIONAL OF RECORD SHALL SUPERCEDE ALL ASSEMBLIES SHOWN IN THIS SECTION, ALSO REFER TO TRUS JOIST® PLACEMENT PLANS (AND MATERIAL SCHEDULES) FOR REQUIRED MATERIAL. Coordinate load requirements with the design professional of record. Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI ® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI ® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut Lines Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, and Trus Joist® are registered trademarks of Weyerhaeuser NR. ©2009 Weyerhaeuser NR Company. All rights reserved. TimberStrand®LSL, TrusJoist® rim board, or (Microllam® LVL with EOR approval) see placement plan. TimberStrand®LSL, TrusJoist® rim board, or (Microllam®LVL with EOR approval) TimberStrand®LSL, TrusJoist® rim board, or (Microllam®LVL with EOR approval) TimberStrand®LSL, TrusJoist® rim board, or (Microllam®LVL with EOR approval) see placement plan. B4 End of joist at centerline of support. Blocking panels required. Load bearing or shear wall above (must stack over wall below when present) Plate nail - 16d (0.135" x 312") at 16" on-center* Floor panel nail - 8d (0.131" x 212") at 6" on-center* A3W W Toe nail - 10d (0.131" x 3") at 6" on-center* When sheathing thickness exceeds 78", trim sheathing tongue at rim board Web Stiffeners required each side at A3._W A3 A3.2A3.1 A3.3 A3.1 WA3.2 WA3.3 TimberStrand®LSL, Trus Joist® rim board, or (Microllam® LVL with EOR approval) see placement plan. For rim board thicker than 1 34" - Attach TJI® Joist to rim board with one 10d (0.128"x3") nail. Top nail from TJI® joist into rim board. - Connect corner with four 10d (0.128"x3") nails. Toe nail from side of parallel closure into rim board. *Conventional construction code minimum for use with A3 only. See the Trus Joist TJI® Specifier's Guide, #TJ-4000, and the Trus Joist® Rim Board Specifier's Guide, #TJ-8000, for A3.1-A3.3 installation specifications and applications. Double top plate Stud Kingstud Header plate stops at inside face of trimmers Header - per plan (bears directly on trimmers) Trimmers - per plan Header cripple Typical Header Detail Window/ Door Opening Only header openings and roof loads which affect Trus Joist product sizes have been denoted on this layout. In addition to any CS detail callouts shown, solid blocking and/or squash blocks are required to provide vertical load transfer from all concentrated load locations to foundation below. See pocket framer guide for appropriate detail(s). ASSUMED BEARING LENGTH FOR BEAMS At parallel walls assume 1-1/2" end bearing, at perpendicular walls assume full wall width end bearing UNO. ALLOWABLE JOIST SHIFTS Individual joists can be shifted up to 3" maximum from their on-center spacing to avoid hanger interference/plumbing drops/post. (DO NOT EXCEED 24" O.C. MAXIMUM SPACING) CANTILEVERS/TRUSSES Design assumes all trusses at floor cantilevers are connected to the wall and NOT to the Trus Joist rimboard. If trusses need to connect to the Trus Joist rimboard, contact Weyerhaeuser for a connection detail prior to installation. JOIST & BEAM HANGER FACE NAILING REQUIREMENTS* FOR 3 & 4 PLY SUPPORTING MEMBERS For IUS or THF Hangers - Use 10d (0.148") x 3" nails. For MIU, HU, HHUS, HGUS or HD, THD, THDH Hangers - Use 16d (0.162") x 3-1/2" nails. *For hangers that have joist fasteners/connections, fill all holes with the manufacturer's recommended fasteners. **FLOOR & ROOF DESIGN PARAMETERS** Face mount hanger Top flange hanger Verify column capacity and beam bearing length. See current iLevel® literature. L5L1 BEARING AT COLUMN Column See current Trus Joist® literature for framing connectors L6 Additional nailing or bolting may be required with side-loaded multiple-member beams. Refer to current product literature. CONNECTION OF MULTIPLE PIECES OF TOP-LOADED BEAMS (1) Minimum of 3 rows 10d (3" x 0.128") nails at 12" o.c. Minimum of 4 rows 10d (3" x 0.128") nails at 12" o.c. for 14" and deeper beams If using 12d (314") or larger nails, the number of nailing rows may be reduced by one. (1) Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams. 312" Width Pieces: Minimum of 2 rows 12" bolts at 24" o.c. staggered 134" Width Pieces: L2 L3 Protect untreated wood from direct contact with concreteL4 BEARING AT WALL BEARING FOR DOOR OR WINDOW HEADER Strap per code if top plate is not continuous over header BEAM TO BEAM CONNECTION BEARING AT CONCRETE WALL TimberStrand®LSL, Trus Joist® rim board, (Microllam® LVL with EOR approval), or TJI® blocking for lateral support BEAM DETAILS 2' TJI® JOIST 2" 2x6 (min.) solid sawn or 4 12" wide Timberstrand® LSL rim board, full length in bay and tight to each joist flange. Connect to plate with 8d (0.113" x 2 38") nails at 6" on-center. 2416 span rated sheathing (716" Min.). Attach with 8d (0.113" x 2 38") nails at 6" on-center along panel edges and in field. Use pressure treated plywood for ground level cantilevers.E1 ALT WARNING Joists are unstable until braced laterally, Safety bracing required during installation. Lateral load transfer for this detail is 180 PLF (pounds per lineal foot). Additional connections may be required to transfer lateral loads from wall above. 16' max deck2' 11 7/8" - 16" TJI® 2" 6" 16' max deck2' 9 1/2" TJI®6" 2x_ Furring 2416 span rated sheathing (716" Min.). Attach with 8d (0.113" x 2 38") nails at 6" on-center along panel edges and in field. Use pressure treated plywood for ground level cantilevers. Inverted hanger (see hanger list on Trus Joist structural layout) Treated ledger 1 18" x 11 7/8" Trus Joist® rim board Inverted hanger (see hanger list on iLevel structural layout) Treated ledger E1 ALT LA 2416 span rated sheathing (716" Min.). Attach with 8d (0.113" x 2 38") nails at 6" on-center along panel edges and in field. Use pressure treated plywood for ground level cantilevers. E1 ALT LA 9.5 2x6 (min.) solid sawn or 4 12" wide Timberstrand® LSL rim board, full length in bay and tight to each joist flange. Connect to plate with 8d (0.113" x 2 38") nails at 6" on-center. Timberstrand ® LSL rim board to match TJI® depth 2x6 (min.) solid sawn or 4 12" wide Timberstrand® LSL rim board, full length in bay and tight to each joist flange. Connect to plate with 8d (0.113" x 2 38") nails at 6" on-center. WARNING Joists are unstable until braced laterally, Safety bracing required during installation. Lateral load transfer for this detail is 180 PLF (pounds per lineal foot). Additional connections may be required to transfer lateral loads from wall above. WARNING Joists are unstable until braced laterally, Safety bracing required during installation. Lateral load transfer for this detail is 180 PLF (pounds per lineal foot). Additional connections may be required to transfer lateral loads from wall above. Attach reinforcement to TJI® joist with 8d (212") common nails at 6" on- center. When reinforcing both sides, stagger nails. E3E2 2 '-0" m a x im umFace grain horizontal 4'-0" length of 34" reinforcement on one side at E2, both sides at E3 ALT ALT Timberstrand ® LSL rim board to match TJI® depth 2x6 (min.) solid sawn or 4 12" wide Timberstrand® LSL rim board, full length in bay and tight to each joist flange. Connect to plate with 8d (0.113" x 2 38") nails at 6" on-center. 2416 span rated sheathing (716" Min.). Attach with 8d (0.113" x 2 38") nails at 6" on-center along panel edges and in field. Use pressure treated plywood for ground level cantilevers. WARNING Joists are unstable until braced laterally, Safety bracing required during installation.Lateral load transfer for this detail is 180 PLF (pounds per lineal foot). Additional connections may be required to transfer lateral loads from wall above. Timberstrand ® LSL rim board to match TJI® depth UNLESS NOTED OTHERWISE FLOOR LIVE LOAD DEFLECTION CRITERIA: L/480 FLOOR LIVE LOAD: 40 PSF FLOOR DEAD LOAD: 10 PSF SNOW LIVE LOAD: 35 PSF ROOF DEAD LOAD: 20 PSF (TRUSSED ROOFS) ROOF DEAD LOAD: 15 PSF* (TJI/RAFTER) *Dead Loads are adjusted for slope correction TJI® blocking panel A1 PB1 1 3 jo ist s pan 8 ' m a x. Apply subfloor adhesive to all contact surfaces Option #3: Option #1: Option #2: TJI® Joist blocking with end blocks installed at 13 joist-span locations using two 8d (0.113" x 212") nails or 2 12" screws, typical 2x_ strapping installed at 13joist-span locations using two 2 12" screws per joist, typical Directly applied ceiling When specified on the layout, one of the above bracing options is required Additional Notes 1.5E TimberStrand®LSL Prescriptive Chart 13 depth 2 x diameter of the largest hole (minimum) 8" See illustration for allowed hole zone 1114"-11 78" 14"-16" 914"-912" 358" 458" 3" Round holes only General Notes No holes within 8" of joist ends. Maximum Round Hole SizeJoist Depth Allowed hole zone 1.5 E TimberStrand® LSL 8" Round holes larger than 3-5/8" up to 7-1/4" max. in 1.5" x 11-7/8" 1.5E TimberStrand LSL joist only Edge of large holes need to be at least 4 times the diameter of the largest hole (for a 7-1/4" hole, the closest distance allowed to the next hole is 29", even if the next hole is a small 12" diameter hole). The hole must be centered within the joist vertically. No square or rectangular holes No more than (2) holes between 3-5/8" and 7-1/4" diameter allowed per span. See chart below for minimum distance from inside face of bearing to edge of hole for holes larger than 3-5/8" but not greater than 7.25" Minimum distance from edge of hole to inside face of bearing (end or intermediate) 4"5"6.5"7.25" 2'-0"2'-0"3'-0"3'-6" the area of a 7-1/4" circumscribed hole A smaller hole can be drilled within centered in the depth of the joist circumscribed 7-1/4" hole smaller hole drilled withincircumscribed area of 7-1/4" hole assuming the circumscribed hole is a minimum of 3'-6" from face of bearing 1-1/2" x 11-7/8" 1.5E TimberStrand LSL floor joist Sales Presentation Drawing:No structural or dimensional check has been performed on this drawing. Lyman Companieswould only be responsible for the individual member design, based on the assumed or knownvertical loads. The Builder or General Contractor is responsible for the structure(s) overalldesign, and it is strongly recommended that all drawings and calculations be reviewed by theengineer of record for this particular project.PDF created with pdfFactory Pro trial version www.pdffactory.com ADD - EGRESS HEADER PlotID Length Product Plies Net Qty TSHd4-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 ADD - WALKOUT HEADERS PlotID Length Product Plies Net Qty TSHd1-2 14' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd4-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 4 ADD - LOOKOUT HEADERS - ABC PlotID Length Product Plies Net Qty TSHd2-2 12' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd4-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 Start Joist Layout Here. ADD - LOOKOUT HEADERS W/ CORNER FP OPTION PlotID Length Product Plies Net Qty TSHd3-3 12' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 3 3 TSHd4-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 Framing Connector Summary PlotID Qty Manuf Product Backer Blks Web Stiff H1 16 Simpson LUS210 No No Products PlotID Length Product Plies Net Qty FBk1 1' 5 11/16"11 7/8" TJI® 210 1 1 TS1 44' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 3 TS2 30' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 4 TS3 28' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 12 TS4 16' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 12 TS5 12' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 5 TS6 8' 0"1 1/2" x 11 7/8" 1.5E TimberStrand® LSL 1 4 TS8-3 14' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 3 3 TS7 14' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS9-3 10' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 3 3 TS11-2 8' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 6 TS10 8' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS12 4' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 2 STRm1 16' 0"1 1/8" x 11 7/8" TJ® Rim Board 1 12 Accessories PlotID Length Product Plies Net Qty 23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF 1 50 ALL ELEVATIONS SOIL PRESSURE BLOCKING PlotID Length Product Plies Net Qty Soil Pressure Blkg 116' 0"11-7/8" TJI® 210 1 1 ADD - FULL FOUNDATION PlotID Length Product Plies Net Qty Not Shown 44' 0"1-1/2" x 11-7/8" 1.5E Timberstrand LSL 1 1 B1 B2 B2 A3 A3 A3 A3 A3 A3 A3 A3 CSCS CS CS CS CS CS CS B2 CS B5 B5 TS8-3 TS9-3 TS11-2 TS11-2 TS11-2TS7TS12TS12TS10TSHd4-2 TSHd1-2 TSHd4-2TSHd4-2 TSHd2-2 BBOHd1-2 TSHd4-2 TS6TS5STRm1STRm1STRm1STRm1STRm1STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 FBk1 4.5" w/ Corner Fireplace Option TSHd3-3 BBOHd1-2 TSHd4-2 3" 3" 1' 3 13/16"1' 9 3/4" 1' 3 15/16" TS3 19.2" O.C. TS4 19.2" O.C. TS4 19.2" O.C.TS4 19.2" O.C. TS6 19.2" O.C. TS5 19.2" O.C. TS2 19.2" O.C. H1 H1 H1 H1 TS1 19.2" O.C. 3"3"3"3" 3"3" 3"3" 3.5" 4.5" WALKOUT OPTION LOOKOUT OPTION ELEVATION A,B,C LOOKOUT OPTION w/ CORNER FP OPTION EGRESSOPTION Full Foundation: 1-1/2" LSL 1.5E flush with canted sill plate. LSL attached to Rim held to inside lining up with concrete foundation. (1-1/2" LSL not shown on layout.) All joist blocking including soil pressure joist blocking can be either 210 or 360 series TJI or 1-1/2" Timberstrand LSL 1.5E material. NO MATERIAL CHANGE FOR FIREPLACE OPTIONS. 2" brg on expanded garage option 2-5/8" brg 2-5/8" brg 5" brg on expanded garage option 5-1/4" wide column 7" wide column on garage expansion option ADD - LOOKOUT HEADERS - DE PlotID Length Product Plies Net Qty TSHd3-3 12' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 3 3 TSHd4-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd3-3 BBOHd1-2 TSHd4-2 3"3" LOOKOUT OPTION ELEVATION D,E Weyerhaeuserprepared theseplans for the specificationof Trus Joistproductsbased on project information provided to us. This service issolelyintendedfor product application assurance; and, is not intendedtocircumventthe need for a design professional as determined by thebuilding codes.The designer of record and/or builder/framer isresponsible to assure thesedrawings are compatible with the overall project.Copyright 2009 Weyerhaeuser NR Company. All rights reserved.Anyunauthorized copying of reproductionwill constitute an infringement of copyright.Architectural Drawings Prepared By:LENNAR - MNStructural Drawings Prepared By:N/A12/16/13N/ALENNAR - MN4014 WASHBURNALL ELEVATIONSRev.ByDateJLH9-20-18CommentsAdjusted garage expansion option.Drawn By:ALAN GOriginal Date:8/13/12FirstFloor Framing Plan Scale: 1/4" = 1'-0" R12-152106 4014 B Sheet 2 of 3 Structural Framer's Pocket Guide. Access with your Smart Phone. http://woodbywy.com/document/tj-9001/ Have a damaged joist or beam?File an electronic damage report forprompt service from your regionaltechnical office. Scan the QR Codewith your smartphone or go to: www.damagereport.w Specification Teamservice.request@weyerhaeuser.com(888)453-8358 . . . . . . . .www.woodbywy.comLack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY BRACING INCLUDES: Blocking, Hangers, Rim Board, Sheathing, Rim Joist, Strut Lines Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. Properly install all blocking, hangers, rim boards, and rim joists at TJI® joist end supports. 2. Establish a permanent deck (sheathing), fastened to the first 4 feet of joists at the end of the bay or braced end wall. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area and to each joist. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within ½" from true alignment. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: BlockingHangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. ©2013 Weyerhaeuser NR Company. All rights reserved. THINK SAFETY - READ INSTALLATION INFORMATION BEFORE PROCEEDING A COMPLETE JAVELIN® LAYOUT INCLUDES THEWEYERHAEUSER FRAMER'S POCKET GUIDE. Only header openings and roof loads which affect Weyerhaeuser product sizes have been denoted on this layout. In addition to any 'CS' detail callouts shown, solid blocking and/or squash blocks are required to provide vertical load transfer from all concentrated load locations to foundation below. See Pocket Framer's Guide for appropriate detail(s). 3" adjustment allowedfor joist spaced 19.2" o.c. or less to accommodate plumbing drops. DO NOT CUT JOIST FLANGES. Thislayout is intended for the use of Trus Joist® engineered wood products only. The substitution of other engineered wood products with thislayout isNOT PERMITTED. Please identify the TJI® , TimberStrand® LSL , Microllam® LVL , and Parallam® PSL stamps on the product to ensure that thislayout is valid for the products actually installed.Sales Presentation Drawing:No structural or dimensional check has been performed on this drawing. Lyman Companieswould only be responsible for the individual member design, based on the assumed or knownvertical loads. The Builder or General Contractor is responsible for the structure(s) overalldesign, and it is strongly recommended that all drawings and calculations be reviewed by theengineer of record for this particular project.PDF created with pdfFactory Pro trial version www.pdffactory.com Start Joist Layout Here. ADD - W/ CORNER FP OPTION PlotID Length Product Plies Net Qty TSHd2-2 10' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 REMOVE - W/ CORNER FP OPTION PlotID Length Product Plies Net Qty TSHd1-2 14' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 Framing Connector Summary PlotID Qty Manuf Product Backer Blks Web Stiff H1 13 Simpson HU2.1/9 No Yes H2 1 Simpson HUC412 No No H3 2 Simpson IUS1.81/11.88 No No H4 15 Simpson IUS2.06/11.88 No No Products PlotID Length Product Plies Net Qty F44'44' 0"11 7/8" TJI® 210 1 13 F30'30' 0"11 7/8" TJI® 210 1 3 F24'24' 0"11 7/8" TJI® 210 1 3 F20'20' 0"11 7/8" TJI® 210 1 3 F18'18' 0"11 7/8" TJI® 210 1 8 F16'16' 0"11 7/8" TJI® 210 1 8 FBk1 4' 3 1/4"11 7/8" TJI® 210 1 1 M1-3 22' 0"1 3/4" x 11 7/8" 2.0E Microllam® LVL 3 3 M2-2 14' 0"1 3/4" x 11 7/8" 2.0E Microllam® LVL 2 2 TS1-2 18' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 TS2-2 14' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 TS3 12' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS4 8' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS5 6' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS7-2 4' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 TS6 4' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 1 TS8-3 8' 0"1 3/4" x 7 1/4" 1.55E TimberStrand® LSL 3 3 TS9 20' 0"3 1/2" x 7 1/4" 1.3E TimberStrand® LSL 1 1 STRm1 16' 0"1 1/8" x 11 7/8" TJ® Rim Board 1 10 Wall Framing PlotID Length Product Plies Net Qty TSHd1-2 14' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd2-2 10' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd4-2 8' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 4 TSHd5-2 6' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 Accessories PlotID Length Product Plies Net Qty 9 1/8"3/4" x 2 5/16" Web Stiffeners 1 26 23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF 1 63 B1 B4 A3 A3 A3 A3 E1 CS CSTSHd1-2 TSHd4-2 TSHd5-2 TSHd4-2 TS7-2 TS2-2 M2-2 TS3TS4 TSHd2-2 M1-3 BBO8 TS8-3 TS9STRm1 STRm1STRm1STRm1 STRm1 STRm1 STRm1 STRm1STRm1 FBk1FBk1TS6 TS54' 0" TS1-2CS H2H3 TSHd2-2 1' 6 3/16" 1' 5 3/16" 1' 10 3/16" 1' 5 1/4" 1' 9 1/8"1' 5 7/16" 2' 0 1/4" 1' 3 7/8" 1' 11 5/16" 1' 3 1/16"1' 3 15/16" 1' 2 9/16" 4 5/8" 1' 6 3/16" 1' 11 9/16" 1' 2 7/8"H3F18' 19.2" O.C. F30' 19.2" O.C. F16' 19.2" O.C. F20' 19.2" O.C. F24' 19.2" O.C. F44' 19.2" O.C. H4 H4 H4 H4 H1 2 x 10 MIN. BOTTOM CHORD REQUIRED 3"3" ALT. 3" ROOF TRUSSES ASSUMED TO BE SUPPORTED BY WALL AND NOT NAILED INTO TJ® RIMBOARD. PLEASE VERIFY PRIOR TO CONSTRUCTION AS ADDITIONAL MATERIALS MAY BE REQUIRED NO MATERIAL CHANGE FOR SERENITY BATH OPTION. Can Light Garage Headerdesigned toL/600 TL for Brick Load Deflection. CORNER FIREPLACE OPTION Free Standing Tub Option - shift this joist 8-1/2" away from stairs. Standard Bath Serenity Bath OPT 3"3" Roof - Elevation B PlotID Length Product Plies Net Qty TSHd1-2 14' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 TSHd1-2 BBOHd4-2BBOHd3-2 BBOHd2-2 BBO64BBO11 BBOHd4-2 Interior bearing wall required when 4'-0" expanded garage option is selected. REMOVE - ELEVATION B GARAGE EXPANSION PlotID Qty Manuf Product Backer Blks Web Stiff H2 1 Simpson HUC412 No No REMOVE - ELEVATION B GARAGE EXPANSION PlotID Length Product Plies Net Qty F44'44' 0"11 7/8" TJI® 210 1 2 M2-2 14' 0"1 3/4" x 11 7/8" 2.0E Microllam® LVL 2 2 TS1-2 18' 0"1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 TSHd2-2 10' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 2 2 9 1/8"3/4" x 2 5/16" Web Stiffeners 1 4 ADD - ELEVATION B GARAGE EXPANSION PlotID Length Product Plies Net Qty F28'28' 0"11 7/8" TJI® 210 1 2 F18'18' 0"11 7/8" TJI® 210 1 2 FBk1 11' 5 1/8"11 7/8" TJI® 210 1 1 M3-3 14' 0"1 3/4" x 11 7/8" 2.0E Microllam® LVL 3 3 TSHd3-3 10' 0"1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 3 3 STRm1 16' 0"1 1/8" x 11 7/8" TJ® Rim Board 1 2 9 1/8"3/4" x 2 5/16" Web Stiffeners 1 4 CS B1 A3 M3-3 TS3M1-3 BBO57 STRm1STRm1STRm1F18'F18'F28'F28'FBk1 TSHd3-3Girder1' 11 9/16" 1' 2 7/8" 1' 8 1/4" 1' 6 3/16" 2' 0 1/4" 1' 3 3/16" 1' 7 1/2" 1' 10 3/16" H3 19.2" O.C. F24' 19.2" O.C. F44' 19.2" O.C. F44' 19.2" O.C. F44' 19.2" O.C. H1 2 x 10 MIN. BOTTOM CHORD REQUIRED 6" ELEVATION B - GARAGEEXPANSION OPTION Attach Rim to Bottom Chord of Girderwith (3) rows of 16d nails @ 6" o/c Serenity Bath OPT Garage Headerdesigned toL/600TL for Stone Load Deflection. Standard Bath from stairs. 6"Weyerhaeuserprepared theseplans for the specificationof Trus Joistproductsbased on project information provided to us. This service issolelyintendedfor product application assurance; and, is not intendedtocircumventthe need for a design professional as determined by thebuilding codes.The designer of record and/or builder/framer isresponsible to assure thesedrawings are compatible with the overall project.Copyright 2009 Weyerhaeuser NR Company. All rights reserved.Anyunauthorized copying of reproductionwill constitute an infringement of copyright.Architectural Drawings Prepared By:LENNAR - MNStructural Drawings Prepared By:N/A12/16/13N/ALENNAR - MN4014 WASHBURNELEVATION BRev.ByDateJLH4-22-19CommentsAdd brg note to rear corner fp wdw.Drawn By:ALAN GOriginal Date:8/13/12SecondFloor Framing Plan Scale: 1/4" = 1'-0" R12-152106 4014 B Sheet 3 of 3 Structural Framer's Pocket Guide. Access with your Smart Phone. http://woodbywy.com/document/tj-9001/ Have a damaged joist or beam?File an electronic damage report forprompt service from your regionaltechnical office. Scan the QR Codewith your smartphone or go to: www.damagereport.w Specification Teamservice.request@weyerhaeuser.com(888)453-8358 . . . . . . . .www.woodbywy.comRoof HeaderPlan Scale: 3/16" = 1'-0" Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY BRACING INCLUDES: Blocking, Hangers, Rim Board, Sheathing, Rim Joist, Strut Lines Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. Properly install all blocking, hangers, rim boards, and rim joists at TJI® joist end supports. 2. Establish a permanent deck (sheathing), fastened to the first 4 feet of joists at the end of the bay or braced end wall. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area and to each joist. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within ½" from true alignment. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: BlockingHangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. ©2013 Weyerhaeuser NR Company. All rights reserved. THINK SAFETY - READ INSTALLATION INFORMATION BEFORE PROCEEDING A COMPLETE JAVELIN® LAYOUT INCLUDES THEWEYERHAEUSER FRAMER'S POCKET GUIDE. Only header openings and roof loads which affect Weyerhaeuser product sizes have been denoted on this layout. In addition to any 'CS' detail callouts shown, solid blocking and/or squash blocks are required to provide vertical load transfer from all concentrated load locations to foundation below. See Pocket Framer's Guide for appropriate detail(s). 3" adjustment allowedfor joist spaced 19.2" o.c. or less to accommodate plumbing drops. DO NOT CUT JOIST FLANGES. Thislayout is intended for the use of Trus Joist® engineered wood products only. The substitution of other engineered wood products with thislayout isNOT PERMITTED. Please identify the TJI® , TimberStrand® LSL , Microllam® LVL , and Parallam® PSL stamps on the product to ensure that thislayout is valid for the products actually installed.Sales Presentation Drawing:No structural or dimensional check has been performed on this drawing. Lyman Companieswould only be responsible for the individual member design, based on the assumed or knownvertical loads. The Builder or General Contractor is responsible for the structure(s) overalldesign, and it is strongly recommended that all drawings and calculations be reviewed by theengineer of record for this particular project.PDF created with pdfFactory Pro trial version www.pdffactory.com FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20200.0011-1-202020 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2020©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4x4'-0" HOOKS @ 24" O.C. BENT ORDRILLED AND EPOXY GROUTED3'-0"1'-0 " NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT) CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETE STRIPFOOTING PER CODE OR BY BUILDINGDESIGNER, AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN AT LEFT8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/S1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/S2FLOOR TO SILLCONNECTION SEE 1/S2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSGENERAL STRIP FOOTING SIZE GUIDEONE-STORYSTRUCTURE16" WIDE x 8" THICK20" WIDE x 8" THICKTWO-STORYSTRUCTURE20" WIDE x 8" THICK26" WIDE x 8" THICK2000 PSFSOIL1500 PSFNOTE: TABLE ABOVE IS A GENERAL FOOTING SIZE GUIDE THAT SHOULD BE VERIFIED BY HOMEDESIGNER AND IS BASED ON 25'-0" FLOOR SPANS & 50'-0" ROOF SPANSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERS#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)Lennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 55446UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2020. COPYRIGHT HANSON GROUP LLC 2020©DescriptionDateRevisionJanuary 1, 2020Project Number:Date:0.001S22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED,12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/A10'-0" MAX TO T.O.S. 1'-8" MAX FLASHING & WOODPROTECTION BYOTHERSFLOOR FRAMING ORBLOCKINGFLOORCONNECTIONSEE 1/S2 &2/S2C.I.P. CONCRETEWALL SEEADJACENTPLANS FORTHICKNESS &MAXIMUM WALLLENGTHSSEE FULLHEIGHT WALLSECTION 5/S1FORREINFORCINGSTOOPSLAB BYOTHERS13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL3'-0" FULL HEIGHT BASEMENTMIN FULL HEIGHT FULL HEIGHT EXAMPLE CORNEROR STRAIGHT WALLOPTIONS -TYPSTOOP AREA8" MIN C.I.P. CONCRETEWALL SEE FULL HEIGHTWALL SECTION 5/S1NOTES:1.ADD RETURN WALLS OR BUTTRESSES IN STOOP AREA AS SHOWN IF OVERALL STOOP CENTER TO CENTERWIDTH EXCEEDS DIMENSIONS SHOWN.2.STOOP WALLS REQUIRE MINIMUM 16" WIDE x 8" DEEP CONCRETE STRIP FOOTING.EXAMPLE '1'EXAMPLE '2'EXAMPLE '3'SLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.TYP * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERBACKFILL BELOWEXTERIOR STOOP SLABSWITH COMPACTEDGRANULAR MATERIALTO FROST DEPTH(4'-0" MINIMUM)NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-8" MAX 2'-6" MIN OPENING 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE 3/S1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.Lennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 55446A SECTION A DateRevisionMarch 9, 2015Project Number:Date:5.085S31Sheets: of2Print Name:Signed: License Number:Nick Hanson2-13-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comLennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 55446Washburn/EH05 Model"B" ElevationMinnesota ConstructionPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.- INDICATES HOLDOWN LOCATIONLOWER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1S3REFERENCE PLANMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)2S3REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)3S3REFERENCE PLANHOUSE PLAN FRONT ELEVATION SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)4S3REFERENCE ELEVATIONTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONSCORNER FIREPLACE OPTIONCONSTRUCT PORTALFRAME AS SHOWN IN 1/S4BRACED WALL LINEBRACEDWALL LINE(4-FT)(4-FT)BRACED WALL LINEBRACEDWALL LINE(4-FT)(4-FT) (4-FT) (4-FT)(4-FT)(4-FT)(4-FT)(3-FT)(4-FT)(3-FT)BRACEDWALL LINE(4-FT)BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACED WALL LINE (4-FT)(4-FT)(4-FT)(4-FT) (4-FT)(4-FT) (5-FT)(5-FT)(4-FT)(4-FT)(4-FT)(3.25-FT)(3.25-FT)(6-FT)(6-FT)(6-FT)CONSTRUCT PORTALFRAME AS SHOWN IN 1/S4(4-FT)BRACEDWALL LINEBRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)(3.5-FT)(4-FT)(4.5-FT)(4-FT)BRACEDWALL LINE(4-FT)(4-FT)BRACED WALL LINE (4-FT)COPYRIGHT HANSON GROUP, LLC 2020©2x4 BLOCKING BETWEEN ROOFTRUSSES NAILED TO TOPPLATES w/ (3) 8d NAILS EACHNAIL EACH JOIST TOTOP PLATE w/ (3) 8dTOENAILSNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"INTERIOR BEARING WALLINTERIOR NON-BEARING WALLPROVIDE FULL DEPTHBLOCKING BETWEENJOISTS NAILED TOTOP PLATES w/ (3) 8dNAILS EACHNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE ROOFTRUSS DIRECTLY INLINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 8dTOENAILS @ 6" O.C.PROVIDE JOISTDIRECTLY IN LINEw/ BRACED WALLPANEL FASTENEDTO PLATES w/ 8dTOENAILS @ 6" O.C.THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE “MAIN WINDFORCE RESISTING SYSTEM” FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.NAIL EACH TRUSS TO TOPPLATE w/ (3) 8d TOENAILSNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEENTRUSSES NAILED TOTOP PLATES w/ (3) 8dNAILS EACHNAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSSDIRECTLY IN LINEw/ BRACED WALLPANEL FASTENEDTO PLATES w/ 8dTOENAILS @ 6" O.C.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)USP MPA1FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSUSP MPA1FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSUSP MPA1FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSUSP MP4FFRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSUSP MP4FFRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLROOF TRUSSFASTENED TOPLATES w/ 8dTOENAILS @6" O.C.NAIL RIM TOPPLATES w/ 8dTOENAILS @6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/ 8dNAILS @ 6" O.C.NAIL BOTTOMPLATE TOLADDER TRUSSw/ (3) 16d NAILSEVERY 16"ROOF TRUSSESFASTENED TO PLATESw/ (3) 8d TOENAILS &USP RT7 CLIP2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATES w/(3) 8d NAILS EACHNAIL EACH JOISTTO TOP PLATES w/(3) 8d TOENAILSNAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL EACH TRUSSTO TOP PLATES w/(3) 8d TOENAILSNAIL BOTTOMPLATE TO RIBBONBRACE / TRUSS w/(3) 16d NAILSEVERY 16"FRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESSCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE.CONSTRUCTION IS TO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MOREINFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C AT PANEL EDGES AND 12" O.C. ATINTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIPS OR EQUIVALENT AND (3) 8d TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.C AT PANEL EDGES AND 12" O.C. ATINTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (8) 16d NAILS INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (2) 10d FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.ACCEPTABLE AT CORNER STRAP LOCATIONS TO HAVE TWO FULL HEIGHT STUDS ORIENTED IN EITHER DIRECTIONFASTENED TOGETHER w/ 8d x 3" LONG NAILS @ 3" ON-CENTER. 'CALIFORNIA CORNERS' OR TRADITIONAL CORNERSARE ACCEPTABLE PROVIDED FULL HEIGHT SAWN BLOCKING STUD IS DIRECTLY BEHIND FLAT PORTION OF STUDSFASTENED TOGETHER IN A SIMILAR FASHION.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:90 MPH EXP. BCODE2015 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTExterior Sheathing2-13-201Description COPYRIGHT HANSON GROUP, LLC 2020©DateRevisionMarch 9, 2015Project Number:Date:5.085S42Sheets: of2Print Name:Signed: License Number:Nick Hanson2-13-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comLennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 55446Washburn/EH05 Model"B" ElevationMinnesota ConstructionS4FRAMING DETAILGARAGE FRONT PORTAL FRAME1NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAILUNLESS NOTED OTHERWISE.16'-2"±2'-5"±LENGTH OF CONTINUOUS HEADER2'-11"±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUDLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF WALL HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)FOUNDATION WALL BELOWNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.USP STAD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 3/S4 FOR ALTERNATIVE OPTIONS)58" Ø ANCHOR BOLT (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)USP MSTC40 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DLARGE HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS ON S3CONTINUOUS HEADER TO SUPPORTVERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)BRACED WALL PANELFASTEN BOTTOM PLATE TOJOIST/BLOCKING w/ (3) 16dNAILS EVERY 16" O.C.CANTILEVERED FLOORJOIST BY SUPPLIERFRAMEWALL / BRACEDWALL PANEL BELOWBLOCKING BETWEEN JOISTS AS FOLLOWS:·FLAT 2x4 TOP & BOTTOM OR JOISTMATERIAL OR SAWN BLOCKING·34" PLYWOOD SHEET NAILED TO 2x4's w/(8) 8d NAILS TOP & BOTTOM·CIRCULAR HOLE UP TO 8"Ø MAY BE CUTINTO CENTER OF PLYWOODNAIL FLOOR SHEATHING TOBLOCKING w/ 8d NAILS @ 6" O.C.FASTEN BOTTOM 2x4 w/ (3) 16dNAILS EVERY 16" O.C. SECTION 2S4AT BRACED WALL PANELS ABOVECANTILEVERED FLOOR FRAMING(REFER TO PLAN FOR APPLICABLELOCATIONS)ALTERNATEHOLDOWN AALTERNATEHOLDOWN BFLOORSYSTEMALTERNATE RAISEDHOLDOWN AFLOORSYSTEMALTERNATE RAISEDHOLDOWN BPOST-INSTALLED HOLDOWN OPTIONS3S4FRAMING DETAILUSP HTT45 HOLDOWNANCHOR AT LOCATIONSSHOWN NAILED TO DOUBLESTUDS & 12"Ø x 12" LONGSIMPSON TITEN HD SCREW-INANCHOR INTO CONCRETEUSP MSTCM40 STRAP ATLOCATIONS SHOWN NAILEDTO DOUBLE STUDS & 14" x214" CONCRETE SCREWS(TAPCON, TITEN, OR EQUIV.)INTO FOUNDATIONCONCRETEFOUNDATIONBELOW12"Ø THREADEDROD w/ NUT &WASHER ATHOLDOWN END12"Ø SIMPSONTITEN HD RODCOUPLER w/ 8"EMBED INTOCONCRETECONCRETEFOUNDATIONBELOWUSP HTT45 HOLDOWNANCHOR AT LOCATIONSSHOWN NAILED TODOUBLE STUDSUSP MSTCM60 STRAP ATLOCATIONS SHOWN NAILEDTO DOUBLE STUDS & 14" x214" CONCRETE SCREWS(TAPCON, TITEN, OR EQUIV.)INTO FOUNDATIONALTERNATE B HOLDOWNS ARE TO HAVECORROSION PROTECTION BY OTHERSIF USED IN AN EXTERIOR APPLICATIONEXPOSED TO THE ELEMENTS.NOT TO EXCEED 12'-0"(2)58" Ø ANCHOR BOLTS (7" MIN. EMBED) w/2" x 2" x 316" PLATE WASHERSExterior Sheathing2-13-201Description S4FRAMING DETAILPORCH END WALL2INFO APPLIES SYMMETRICALLY ACROSS DETAIL.COPYRIGHT HANSON GROUP, LLC 2018©PARTIAL MAIN LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1S4REFERENCE PLANDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM OF THE FOUR SEASON PORCH FOR ASINGLE−FAMILY RESIDENCE. CONSTRUCTION IS TO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRYPRACTICE, AND THE CODE.1. THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MOREINFORMATION.2. REFER TO SHEETS S3−S4 FOR REMAINING MAIN WINDFORCE RESISTING SYSTEM REQUIREMENTS.WALL STUDS (10’ OR LESS): SPF STUD GRADE OR BETTERWALL STUDS (OVER 10’): SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER: SPF NO.2 GRADE OR BETTERTREATED LUMBER: SYP NO.2 GRADE OR BETTERLSL: 134" WIDTH − 1.55E OR BETTEROR 112" WIDTH − 1.7E OR BETTERLVL: 134" WIDTH − 1.9E OR BETTERROOF SNOW LOAD: 35−42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD: 90 MPH EXP. B2015 MINNESOTA RESIDENTIAL CODESIDE WALLS MAY BESTANDARD FRAMINGFASTEN BOTTOM PLATE w/(3) 16d NAILS EVERY 16"LSL/LVL FLUSHBEAM BYSUPPLIER8’−0" SINGLE SHEET TYP.USP PAU66 POST BASE w/58"Ø x 8" USP WEDGE BOLTSCREW−IN ANCHOR6x6 POSTCROSS HATCH AREAS INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDES OF POSTS & 34"OR THICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO INTERIOR SIDES OF POSTS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED)716" OR THICKER PLYWOOD OROSB SHEATHING APPLIED TOEXTERIOR SIDES OF POSTSFLUSH BEAMPROVIDE LAYER/S OFPLYWOOD/OSB TO FLUSHOUT BEAM w/ POSTCENTER 6x6 POSTw/ STANDARDPOST BASE & CAP34" OR THICKER PLYWOOD OROSB SHEATHING APPLIED TOINTERIOR SIDES OF POSTS(INSTALL PRIOR TO JOISTS)NAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED& TO PLATES / BLOCKING @ 3" O.C.)USP LSTA24 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN TOP PLATE TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD &(1) 2x6 FULL HEIGHT STUDEACH END OF HEADERLOCATE PANEL JOINT WITHIN 2’−0"FROM CENTER OF WALL HEIGHT ASREQ’D (2x SOLID BLOCKINGREQUIRED AT SHEATHING JOINT)(2) 2x6 BEARINGSTUDS MIN.LENGTH OF CONTINUOUS HEADERFASTEN KING STUD TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.CENTER BEARINGSTUDS BY SUPPLIERFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSLARGER HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILING PATTERN1’−0"±1’−0"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN. 3" WIDTH & MIN. 912" DEPTH REQ’D)FOUNDATION WALL BELOW1’−0"±1’−0"±S4FRAMING DETAILPORCH END WALL w/ LOOKOUTOR WALKOUT FOUNDATION(OPTION−1)3INFO APPLIES SYMMETRICALLY ACROSS DETAIL.FASTEN BOTTOM PLATE w/(3) 16d NAILS EVERY 16"LSL/LVL FLUSHBEAM BYSUPPLIERUSP MSTC28 STRAPCONNECTION BETWEENSTUDS & FLUSH BEAMNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED& TO PLATES / BLOCKING @ 3" O.C.)USP LSTA24 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN TOP PLATE TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD &(1) 2x6 FULL HEIGHT STUDEACH END OF HEADERLOCATE PANEL JOINT WITHIN 2’−0"FROM CENTER OF WALL HEIGHT ASREQ’D (2x SOLID BLOCKINGREQUIRED AT SHEATHING JOINT)(2) 2x6 BEARINGSTUDS MIN.LENGTH OF CONTINUOUS HEADERFASTEN KING STUD TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.CENTER BEARINGSTUDS BY SUPPLIERFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSLARGER HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILING PATTERN1’−0"±1’−0"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN. 3" WIDTH & MIN. 912" DEPTH REQ’D)FOUNDATION WALL BELOW113’−0"±58" Ø THRU BOLTSOR 10" LONG LAGSCREWS ATLOCATIONS SHOWN(MAY SUPSTITUTE(2) 38" x 8" GRK RSSFOR EACH 58"BOLT/LAG SCREW)116x6 POSTS TYP. 6x6 DIAGONALMEMBERSUSP PAU66 POST BASE w/58"Ø x 8" USP WEDGE BOLTSCREW−IN ANCHORUSP LFTA6 TWIST STRAPCONNECTION BETWEENFLUSH BEAM & POSTPAIR OF USP PB66−6TZ POSTPOST CAPS AT ALL POSTSS4FRAMING DETAILPORCH END WALL w/ LOOKOUTOR WALKOUT FOUNDATION(OPTION−2)4INFO APPLIES SYMMETRICALLY ACROSS DETAIL.CONSTRUCT END WALL AS SHOWN IN 2/S4(CONSTRUCT AS SHOWN IN 3/S4 OR 4/S4FOR LOOKOUT OR WALKOUT LOTS)(4−FT)(5−FT)DescriptionDateRevisionJuly 24, 2018Project Number:Date:5.085S51Sheets: of1Print Name:Signed: License Number:Nick Hanson7−24−18 46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612−708−3572www.hansongroupmn.comLennar Corporation16305 36th Ave N. Suite 600Plymouth, MN 554464014 ModelAll ElevationsMinnesota ConstructionPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP’S DESIGN.BRACEDWALL LINEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34 MP34A35MPA1H2.5RT7HTT5 HTT45LSTASTRAPSAMELTP4 MP4FMSTCSTRAPSAMESTHD14/RJ STAD14/RJTITEN HDWEDGEBOLTLPC6ZPB66−6TZABU66 PAU66HARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTUSP MSTC28 STRAPCONNECTION BETWEENSTUDS & FLUSH BEAMFASTEN BOTTOM PLATE w/(3) 16d NAILS EVERY 16"LSL/LVL FLUSHBEAM BY SUPPLIERUSP MSTC28 STRAPCONNECTION BETWEENSTUDS & FLUSH BEAMNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED& TO PLATES / BLOCKING @ 3" O.C.)USP LSTA24 STRAP ON INSIDE FACE OFWALL (PROVIDE SPACER TO FLUSH OUTHEADER TO WALL STUD THICKNESS)FASTEN TOP PLATE TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD &(1) 2x6 FULL HEIGHT STUDEACH END OF HEADERLOCATE PANEL JOINT WITHIN 2’−0"FROM CENTER OF WALL HEIGHT ASREQ’D (2x SOLID BLOCKINGREQUIRED AT SHEATHING JOINT)(2) 2x6 BEARINGSTUDS MIN.LENGTH OF CONTINUOUS HEADERFASTEN KING STUD TOHEADER w/ (2) ROWS 16dSINKER NAILS @ 3" O.C.CENTER BEARINGSTUDS BY SUPPLIERFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELSLARGER HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDSw/ STANDARD 6"/12" NAILING PATTERN1’−0"±1’−0"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN. 3" WIDTH & MIN. 912" DEPTH REQ’D)FOUNDATION WALL BELOW6x6 POSTS TYP.USP PAU66 POST BASE w/58"Ø x 8" USP WEDGE BOLTSCREW−IN ANCHORPAIR OF USP PB66−6TZ POSTPOST CAPS AT ALL POSTS Smoke CO Smoke -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 40,000 X X 40,000 1360 40,000 3000 3000 1360 3000 .45 .45 .55 40,000 40,000 13.33 13.33 .62 7.3 3.1 4796 719 240 375 375 719 NR 190 95 Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here X R-15 X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: AFUE or HSPF%93% Cfm's " round duct OR " metal duct Not required per mech. code X Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " round duct OR " metal duct New Construction Energy Code Compliance Certificate Heating System MECHANICAL SYSTEMS R-value Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Cooling System Make-up Air Select a Type Perimeter of Slab on Grade InteriorRigid, IsocynurateMineral FiberboardRigid, Extruded Polystyrene Describe other insulated areas Foam, Closed CellTotal R-Value of all Types of InsulationCity 3/20/2020 Mailing Address of the Dwelling or Dwelling Unit Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. 50 GPVL-50 Location of duct or system: Rating or Size Efficiency Lennox Elect 13SEER /EER Output in Tons:3 13ACXN-036 Below Entire Slab Rim Joist (2nd Floor+) Rim Joist (1st Floor) Interior Combustion Air Select a Type Balanced Ventilation capacity in cfms: High: High: Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Total ventilation (intermittent + continuous) rate in cfms: Capacity continuous ventilation rate in cfms: Location of duct or system: 57,936 27,347Residential Load Calculation Heating Loss 82 32,619 Building envelope air tightness: AOSmith Windows & Doors MECHANICAL VENTILATION SYSTEM Cooling Load 0.31 192 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Heating Gain 19176 Impala Avenue Interior R5 + R10 Exterior Lakeville Type: Check All That Apply Insulation Location Foundation Wall Model Appliances Lennox Manufacturer Fuel Type Nat Gas ML195UH070XE36 0.29 Solar Heat Gain Coefficient (SHGC): Nat Gas Domestic Water Heater Ceiling, flat Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Average U-Factor (excludes skylights and one door) U: Wall Fiberglass, Batts Name of Residential Contractor MN License Number RADON CONTROL SYSTEMTHERMAL ENVELOPE Foam Open CellNon or Not ApplicableFiberglass, BlownBC001413Lennar Homes 000000Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 03/26/2020 X KP