Loading...
HomeMy WebLinkAboutLA178946 8728 188th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6:126:124:124:126:128:128:124:12 SADDLEAAAABBBBCCCCEEEEDDDD8:128:1228' RIDGE VENT12' RIDGE VENT14' RIDGE VENT 10' RIDGE VENT8:12ROOF PLAN1/8"=1'-0"3 1/2" TRIMAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM5" TRIMTYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN5/4" x 3" - WOODGRAINOVER5/4" x 10" - WOODGRAINWOODGRAIN PANEL5/4" x 3" - WOODGRAIN5/4" x 10" - WOODGRAIN10" SQUARE COLUMN9 1/2"9 1/2"6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM(SIDES)4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)2"=1'-0"1/4"=1'-0"3 1/2" TRIM 5" TRIM1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72725470-A-3.2JORDANDRAWN: 10-2-2015-AWPERMIT/CONSTRUCT:4-8-20-LLKALPANA RESIDENCECUST:JORDAN 'A' FRONTAMERICAN CLASSICF128STEEL PANEL OVERHEAD DOORICE & WATERALUMINUM FLASHINGBEHIND STOOPFFFD1'-0"1'-0"6"9 7/16"HEEL9 7/16"HEEL1'-0"9 7/16"HEEL1'-0"9 7/16"HEEL FADDRESS NUMBERD1286:12 PITCH6:12 PITCH4:12 SADDLE1x4:12 PITCH4:12 PITCH6 1/4"6-1/4" FROM TOP OF THRESHOLDTO TOP OF JOISTDXXXXXRAIN DIVERTER5'-0"REFAVINYL LAP SIDINGPRODUCTCBD5/4X6 CEMENT BD. TRIMREFMATERIAL LEGENDECEMENT BD. SIDINGPRODUCTGFHCEMENT BD. SHAKES5/4X8 CEMENT BD TRIMNOT USEDNOT USEDC.B. BOARD-N-BATTENPC#657: 8-13-2019-LLLOT 5, BLK 3, CHOKECHERRY HILL 4TH8728 188TH STREET WPERMIT/CONSTRUCTIONPLANSOPTIONAL STONELEFT ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTH42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTHREAR ELEVATION1/8"=1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE2x CEDARAF1'-5"1'-0"F1'-0"7 7/16" 7 7/16"1266:12 PITCH1'-0"ASPHALT SHINGLESFLASH OVER ALL EXT OPGS1'-0"AA1'-0"7 7/16"8:12 PITCHA1x CEDAR8:12 PITCH12640% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.28:12 PITCH1'-0"VINYL SIDINGSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/21/2020dmathews MFD FLOOR TRUSSESINSTALL PER MFRS SPECS7'-7"5'-4"5'-3 1/2"5'-6 1/2"UP16R7'-4"A/C12'-11"50'-0"11'-6"49'-0"7'-0"24'-0"18'-0"25'-0"50'-0"19'-0"19'-6"11'-6"1'-7 1/2"1'-7 1/2"1'-4 1/4"1'-10 3/4"35'-0" 12'-6" 10'-0"4'-0" 49'-0" 3'-6"10'-0" 5'-0"18'-0"12'-0"10'-0"5'-9"13'-2"16'-3" M.O.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.16'-3"8'-3" M.O.8'-3"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADEMIN. 3'-6" BELOW GRADE6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLTYP. WINDOW HEAD HEIGHT AT 7'-0" U.N.O.NOTE:8'-4" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRBASEMENT PLAN1/4"=1'-0"BEDROOM226 SQ. FT.W.I.C.FAMILY RM791 SQ. FT.UNFIN. STORAGE3/4B52 SQ. FT.TPH36"16"x8" CONC. FTG.6" CURB, 2" LEDGEPOURED CONC. WALL8" THICK, 8'-4" HIGH2'-0"19'-6"11'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH2-82-62-4HDR2-4DROPPED BEAMCONC. PAD FTG.30x30x12CONC. PAD FTG.30x30x12CONC. PAD FTG.30x30x12ANCHORS AT 6'-0" O.C.BLOCK AT MIDPOINT14x8 CONC FTG6" HALF-HIGH CURBTREATED BOTTOM PLATE2x6 STUDS AT 16" O.C.2x6 BRNG WALL2x6 BRNG WALL2x6 BRNG WALLUNEXCAVATEDSUMP16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C2X6'-0"OF MAIN LEVEL SUBFLOORFRAME WALL TO UNDERSIDEACHVWHF.D.BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMBRACINGFOUND.SYSTEM4'-0" MAX FBBRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMBRACINGFOUND.SYSTEMMAX 4'-0"BRACINGFOUNDATIONSYSTEMMAX.COCKSILL2'-0"13'-2"17'-6 1/2"5'-9"4'-11 1/2"DROPPED BEAM (cont)RADONVENT PIPE30x30x12CONC. PAD FTG.B.P.NOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONS36x36x12 CONC. PAD FTG.#5 BARS EACH WAY @ 12" O.C.3" FROM BOTTOMPOINT LOAD FROM ABOVE42x42x12 CONC. PAD FTG.#5 BARS EACH WAY @ 12" O.C.3" FROM BOTTOMPOINT LOAD FROM ABOVE34x48 FBGLSHOWERSURROUND16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH4'-0" 4'-6"CANT. JOISTSTREATED 2x8's 16" ON CENTER16" CONC. PIER FTG6x6 TREATED POSTMIN. 3'-6" BELOW GRADETYPICAL:PORCH ABOVE(2) 2x10 DROPPED BEAMCANT. JOISTS8"4'-9"6'-6"POURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE6'-3 1/2"8"12'-0 1/2"CANT.BEAM5'-4"8" 24" TOWEL BAR JORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LL1302 SQ. FT.NOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM1/2"=1'-0"PORCH SKIRT DETAIL1/2"=1'-0"FRONT PORCH LEDGER SECTION6 1/4"7 1/4"6 3/4"FLASHING ABOVEDOORTHRESHOLDGRADETOP OF SUBFLOORTO TOP OF JOIST4-1/2" FROM1 1/2"AND BELOW 2x8 &2x10 TRTD LEDGERSTRTD 2X8 JOISTS16" O.C.(8) 10d COMMON NAILSTRTD. 2X10 RIPPED(TOP OF FOUND TOBOTTOM OF DECK JOIST)5/4" DECKINGRIM BOARD1-1/8" OSB18" FLOOR TRUSSES(4) PER DECK, RATED AT 750 # EACHSPACED EVENLY, MAX. 24" FROM END OF LEDGERLATERAL LOAD CONNECTION:USP LTS19-TZ w/ LBP12-TZ WASHER1x10 CEDAR SKIRTAT DROPPED BEAM1x10 CEDAR SKIRTAT DECK RIM JOISTBLOCKING AS REQ.FOR SKIRT SUPPORTDROPPED BEAMUSP LTS19-TZ BRACINGAND WOOD BLOCKINGSEE PAGE 5 FOR DETAILS30x30x12CONC. PAD FTG.34x34x14CONC. PAD FTG.WINDOW & DOOR SCHEDULE-WALKOUTCALL-OUTU-FACTORROUGH OPENING6068 SGD0.3172 1/8" X 80"LOCATIONSHGCFAMILY ROOM0.323050 SH0.3136 1/4" X 60 1/4"#11BEDROOM0.310.3110.31FAMILY ROOM2W 3050 SH72 1/8" X 60 1/4"2'-6 1/2"2'-10 1/2"3 1/2x5 1/2 VERSA COLUMNFOUNDATION INSULATIONFRONT FOUNDATION WALL:-17 SQ FT/64 LIN FT= 1.28 RATIOR-10REAR FOUNDATION WALL:-25 SQ FT/50 LIN FT= 0.5 RATIORIGHT SIDE FOUND. WALL:-13-53-68 SQ FT/25 LIN FT= 0.52 RATIOLEFT SIDE FOUND. WALL:- 18-57-74 SQ FT/35 LIN FT= 0.72 RATIO-FOUNDATION INSULATIONRATINGS ARE BASED ONLESS THAN 2.6 AIR CHANGESPER HOUR DURING THE AIRLEAKAGE TESTR-10R-10R-10REQUIREMENTS5-1/4x5-1/4 VERSA COLUMN1/2"=1'-0"FRONT PORCH LEDGER DETAIL18" FLOOR TRUSSES 3/4" 1st FLOOR WALLSSUBFLOOR 9'-1 1/8" BASEMENT WALLS 3/4" SUBFLOOR6 1/4"7-1/4"2x8 PORCHLEDGER2x6 EXTERIOR WALL. 2""MIN...5 1/4" 2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE16" O.C. UNDER 10'-0" SPAN12" O.C. OVER 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.FLOOR TRUSSESBLOCKING, LAID FLAT(2) TRTD 2x12(8) 16D NAILS ON INSIDEBLOCKING, LAID FLATTRTD (2) 2x12(8) 16D NAILS PER SIDE(8) 30D NAILS ON OUTSIDELAG SCREWS1/2" DIAMETERINSTALLED STAGGERED IN 2 ROWSLAG SCREWS W/ WASHER TO BEUSP LTS19-TZ STRAPS TO BE ATTACHED TO DECK JOISTOR 2X12 BLOCKING AND ANCHORED INTO FLOOR TRUSS.(4) STRAPS PER DECK/PORCH, RATED AT 750# EACH,TO BE SPACED EVENLY. MAX 24" FROM END OF DECK LEDGERMINIMUM 3" PENETRATION THRU OSB RIM & FLOOR TRUSS(3) 2x10 DROPPED BEAMCOCKSILL6'-8"1'-0"16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALL18x8 CONC. FTG.8" THICK, 4'-4" HIGH12'-0" LOOKOUT WALL 12'-0" LOOKOUT WALL2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALL18x8 CONC. FTG.8" THICK, 4'-4" HIGH18"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHHD-FLRCPT.CPT.CPT.2W 3050 SH3050 SH2x6 WALKOUT WALL2x6 STUDS AT 16" O.C. 8" POURED CONC. WALLTREATED BOTTOM PLATE6" CURB, 2" LEDGE18x8 CONC. FTG.MIN. 3'-6" BELOW GRADE6'-11"16'-4"14'-2"12'-7"6-0 SGD36x72CONC. PAD8728 188TH STREET WPLAN OPTIONSWALKOUT BASEMENTPLANSCONSTRUCTIONWSTHRU FOOTINGGROUNDING RODInterior BWP Above(2)7-1/4 Versa-Lam(2)9-1/2 Versa-Lam(3)11-7/8 Versa-Lam555UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. WOOD RAILING35'-0" 12'-6"36'-6"5'-0"18'-0" 49'-0"6'-4"7'-0"24'-0"11'-8"25'-0"50'-0"19'-0"19'-6"11'-6"19'-6"13'-2"6'-4"6'-6"6'-8"9'-9"9'-9"5'-5 3/4"6'-0 1/4"REF.END PANEL 10'-8"2'-6"3'-6"1'-11"18'-6"18'-0"5'-2"8'-4"6'-0"19'-6"11'-0"2'-0" 12'-0" 10'-0" 4'-8" 5'-4"4'-8" 49'-0"4'-6"3'-10"1'-7 3/4"3'-10 3/4"4'-8 1/2"2-42-816x7 OVERHEAD DOOR8x7 OVERHEAD DOORFLOOR LINE ABOVE DROPPED BEAM 12'-0 1/2"6'-3 1/2"8"2'-11"3'-5"18'-0"4'-6"5'-9"4'-0"4'-0"14'-2"2-03-02W 3060 SH3040 SH14" TRANSOM3060 SH3060 SH3060 SH2W 3060 SHFAMILYROOMGARAGESLOPE TO DOORS4" CONC FLOOR715 SQ. FT.TYPICAL 2x6 GARAGE WALLSOWNERSENTRYHD-FLRBOOT BENCHFOYERHD-FLRPANTRYHD-FLR2-812" DROPPED SOFFITSTEPS14" MFD I-JOISTSINSTALL PER MFRS SPECSCANT.BEAMDROPPED BEAM8"WOOD PORCH16" WIDE DROPPED SOFFIT(SEE SECTION)DROPPED BEAMDN16RTPH 24" TOWEL BAR9'-8"3'-10"2-4BEDRM #6CPT.3/4BHD-FLR36"4-07'-2"4'-6"2x6 BRNG WALL2x6 BRNG WALL2x6 BRNG WALLFLUSH BEAMDROPPED BEAM6'-11 1/2"1ST FLOOR PLAN1/4"=1'-0"1423 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 8'-0" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C3XRADONVENT PIPEON ALL WALLS & CEILINGGYP. BOARDNOTE: TYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN22x30ATTICACCESS 10" FROM HOUSEDROP PLATES6'-4"3-4 x 8-0 OPG.2'-6 1/2" 3'-6"114 SQ. FT.8'-7"50'-0"3'-1"1 1/2"CPT.UP15RUP1RVERSA-LAM COLUMN5-1/4" x 5-1/4"LAM COLUMN5-1/4" x 7" VERSA-6-1/2" BEARING REQ'D2X8 WALL34x48 FBGLSHOWERSURROUND10'-2"7'-10"DROPPED BEAM5'-4"2x6 BRNG WALL3'-9 1/2"DROPPED BEAM10" FROM HOUSEDROP PLATES2'-0"JORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LLDINETTEHD-FLR2-62-4HDR3'-1 1/2"3'-1 1/2"7'-0"5 1/2"INSIDE FRAMINGINSIDE FRAMING OUTSIDE FRAMING2'-0"2) 2-6 DOOR10'-0"4'-0" SUBFLOOR TO 43 1/2" FROM TOP OF SET KITCHEN WINDOW RGH.OPG. OF WINDOW6"WOOD STEPS5'-6"14" MFD I-JOISTS INSTALL PER MFRS SPECS 14" MFD I-JOISTS INSTALL PER MFRS SPECS 20 AMP.MICRO HOODCIRCUITGASOVENKIT.HD-FLRDW24x60BASE7'-0"8'-0 1/2"3'-5" TOP34 1/2" A.F.F.2x4 WALLS FRAMED4'-4" 5'-0" CABTS. 5'-9 1/4"5'-9 1/4" SINK 5'-4" TOP 5'-10" 5'-1" WALLMFD TRUSSES AT 24" O.C.11'-0"6'-11"4'-1"2'-6"6068 SGD W/6068 SGD W/ TRANS0.3136 1/4" X 48"0.310.3172 1/8" X 94"0.32WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DOOR0.3138.25" X 83.25"FOYER0.2312W 3060 SHDINING ROOM1BEDROOM #62W 3060 SH1DINETTEFAMILY ROOM3060 SH1KITCHEN3040 SH130.3172 1/8" X 72"0.310.3172 1/8" X 72"0.310.3136 1/4" X 72"0.31FRAME SOFFIT AT 7'-6 1/8" FROM TOP SBFLR TO BTM FRAMING 8728 188TH STREET WPLANSCONSTRUCTIONPLAN OPTIONSSTUDY LIGHT PACKAGEDINETTE LIGHT PACKAGEPENDANT LIGHT PACKAGEFAMILY ROOM LIGHT PACKAGESIGNATURE KITCHENSTAIR RAILINGSTUDYSTUDYGAS FIREPLACE COOKTOPHD-FLRHD-FLRGAS FPRGH OPG42"x40 1/8"VENT HOOD TO OUTSIDEIRRIGATIONSYSTEMw/ COAT RACKTILED KITCHENBACKSPLASH5365556666PFHPFH6(2)11-7/8 Versa-Lam(2)9-1/2 Versa-Lam(2)14" Versa-Lam(2)24" Versa-Lam (2)14" Versa-Lam(2)7-1/4 Versa-Lam(2)7-1/4 Versa-Lam 11'-6"7'-0"5'-0"11'-6" 6'-4"11'-2" 35'-0"6'-0" 41'-0"50'-0"13'-6"15'-2"50'-0"13'-6"5'-6"8'-2"10'-9 1/2"19'-0"12'-0 1/2"18'-11 1/2"25'-0"16'-0"41'-0"3'-0"13'-0" 2'-6" 5'-6" 4'-6"8'-6 1/2"3'-4 1/4"5'-9 1/2"5'-6"8'-0"6'-6"7'-0"2'-7"2'-11"6'-0 1/4"6'-0 1/4"7'-9 1/2"3'-0"7'-0"6'-6"7'-8"7'-6"2ND FLOOR PLAN1/4"=1'-0"1580 SQ. FT.LIVING AREANOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-10 1/2" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR2-62-611'-6 3/4"3'-4"2'-2"LINEN2W 3050 SH2W 3050 SH3050 SH2W 3050 SH2040 SHTEMP GL2'-3"8'-11"DN16R2-62-02-6BEDRM #2CPT.BEDRM #3CPT.BEDRM #4CPT.W.I.C.CPT.GIRDER TRUSSW/ WOOD CAP42" HIGH HALF WALLThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C4XJORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LL3040 SHTEMP GLGAMEROOMCPT.3050 SH36'-6"10'-0"3'-8 3/4"42x60FBGL TUBPROVIDEACCESS24" TOWEL BAR72"14'-2"7'-2"7'-1"7'-1"2-48'-4 1/4"2W 3050 SH2-42-4OWNERSBEDRMCPT.W.I.C.CPT.OWNERSBATHHD-FLR2-8WASHDRY6" SPLASH135013502-47'-6"4'-0"3'-6"2-4W.I.C.CPT.W.I.C.CPT.W.I.C.CPT.2-4INSIDE FRAMING2-42x6 WALLRADONVENT PIPE2-47'-6"3'-8"3'-6"2x6 WALLTPH 18'-0"TEMP5-0 FBGLTUB/SHWR22x30ATTICACCESSCENTER OF SHWR HEAD OPG 84" ABOVE SUBFLOOR OWNERS BATH W/1/2"=1'-0"SHOWER BASEFIBERGLASS BASE18"DETAIL 'A'34X60 FIBERGLASSCL16" @ 34" SHWR4'-0"CLSHOWERCONTROLTO CENTER OF SHOWER VALVE SEATS & TOE LEDGES 10-3/4"36"VALVE17-3/16" @ 36" SHWRMFD TRUSSES AT 24" O.C. MFD TRUSSES AT 24" O.C.MFD TRUSSES AT 24" O.C.W/ 36" GLASS PANEL2x4 WALL, 48" HIGHW/ CT SURROUND34x60 FBGL BASE3'-8"TOELEDGEWINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#2W 3050 SH1W.I.C.1BEDRM #4GAME ROOM12W 3050 SH2W 3050 SHOWNERS BR13040 SHOWNERS BATH12W 3050 SH1BEDRM #31BEDRM #2OWNERS BATH3050 SH3050 SH0.310.3172 1/8" X 60 1/4"0.310.3172 1/8" X 60 1/4"0.310.3172 1/8" X 60 1/4"0.310.3172 1/8" X 60 1/4"0.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 48"0.312040 SH0.3124" X 48"0.31124" TOWEL BARLINEN18"BATH #2HD-FLRTPH60"LAUNDHD-FLRSHWRSHELVESNOTES:ALL TOE LEDGES AND SEATSARE 18" OFF THE SUBFLOORBATOE LEDGES ARE MODEL BT-17BY BETTER BENCH SYSTEMSHEIGHT OF SHOWER SHELVES TO BEDEPENDENT ON TILE SELECTIONSMIXER VALVE IS ALWAYSCENTERED BELOW SHOWER HEADCDTHIS DETAIL REFLECTS MODEL #'s,HEIGHTS & LOCATIONS ONLY, ANDDOES REFLECT QUANTITIES PURCHASEDREFER TO DEC SELECTIONS FORSTD & OPTIONAL INCLUDED FEATURES1/3 OFFSET, PARALLELTO VANITYLAUNDRY SHELF8728 188TH STREET WPLANSCONSTRUCTIONPLAN OPTIONSOWNERS BATH TILED SHOWER SURROUNDBATH #2 DOUBLE BOWL VANITY-(2)7-1/4 Versa-Lam(2)7-1/4 Versa-Lam-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).5533 SD/CMDSWPSSSGFISSSDSSThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C5XJORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LLELECTRICAL PLANSEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLESGFI15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEFINISHED BASEMENTWPSUMPA/C1/4"=1'-0"BEDROOMW.I.C.FAMILY RMUNFINISHEDSTORAGE / MECH.3/4BUNEXCAVATEDACHVWHPORCH ABOVEF.D.FANLSCSMART HOMESYSTEM RECEPTACLESLOW VOLTAGESYSTEM RECEPTACLELLLLLLLLLDWS8728 188TH STREET WPLAN OPTIONSWALKOUT BASEMENTPLANSCONSTRUCTION ELECTRICAL PLAN1/4"=1'-0"BEDRM #2SS S SSDSSS S SWPSSSS SSSS WPGFITSSELECTRICAL PLAN1/4"=1'-0"SOWNERSBEDRMROUGH-INCEILING FANS S GFIGFI SSSS FANS SSS1ST FLOOR2ND FLOORSPRINKLERSYSTEMRECEPTACLEUSBCSD/CMDSDSDBEDRM #3BEDRM #4W.I.C.W.I.C.OWNERSBATHW.I.C.W.I.C.W.I.C.SD/CMDS S SDGARAGEOWNERSENTRYFOYERPANTRYKIT.WOOD PORCHThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6XSSSCDINETTECL4'-0"4'-7 1/2"DISP.SSSPEND.PEND.7'-6 1/2"3'-0"7'-7 1/2"LSSFANFANSDSSGFI BEDRM #63/4BFANLSD/CMDSLFAMILYROOMJORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LLGAME ROOMLLLLBATH #2GFISGFISLLLLLLLLLLSTUDYS CHIMESHCPSSSSS2nd SMARTHOME RECEPT.DDDDDDDDLLLLLLLLLLLLLLLLIGHT FIXTURE SCHEDULEDOME LIGHTLED DISC LIGHTRECESSED FIXTLRPEND.PENDANT LIGHTSWALL FIXTURESCEILING LIGHTDLLLLLVENT HOOD TO OUTSIDE TECHTUBEIRRIGATIONSYSTEMCD8728 188TH STREET WPLANSCONSTRUCTIONPLAN OPTIONSSTUDY LIGHT PACKAGEDINETTE LIGHT PACKAGEPENDANT LIGHT PACKAGEFAMILY ROOM LIGHT PACKAGESIGNATURE KITCHENSTAIR RAILINGSTUDYGAS FIREPLACE OWNERS BATH TILED SHWR SURROUNDBATH #2 DOUBLE BOWL VANITY 7XJORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LLThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C1/4"=1'-0"CROSS SECTION C-C9'-1 1/8" 10'-3 7/8"CONC WALL9'-8 3/4" 8'-2"8'-1 1/8"3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORSLOPE TO DOORSW.I.C.GARAGE24'-0"1/4"=1'-0"CROSS SECTION A-A25'-0"OWNERSENTRY4" CONC. FLOORBEDRMOWNERSBEDROOM #69'-1 1/8" 10'-3 7/8"CONC WALL9'-8 3/4" 8'-2"8'-1 1/8"3/4" 250 SUBFLOOR3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORSTUDYPANTRYKITCHENW.I.C.BATH #2BEDRM #3BEDRM #2DROP PLATES 10"AT 2-CAR PORTION OF GARAGE10" 9'-1 1/8" 10'-3 7/8"CONC WALL9'-8 3/4" 8'-2"8'-1 1/8"3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR14" MFD I-JOISTSSLOPE TO DOORSW.I.C.GARAGE22'-0"23'-0"1/4"=1'-0"CROSS SECTION B-B5'-0"41'-0"BEDRM #44" CONC. FLOORROOMGAMEROOMFAMILY18'-0"35'-0"1/4"=1'-0"LONGITUDINAL SECTION D-D8'-2 7/16"20'-0"4127'-4 7/16"18" MFD FLOOR TRUSSES1'-0"1245 7/16"18'-0"4'-0"MFD TRUSS1'-0"1267 7/16"6'-0"35'-0"14" MFD I-JOISTS18" MFD FLOOR TRUSSESMFD TRUSS1'-0"1267 7/16"1'-0"1267 7/16"16" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE1'-4"41'-5"6 3/16"DROPPED BEAM5'-4"6'-0"6 1/4"18" MFD FLOOR TRUSSES14" MFD I-JOISTSDROPPED BEAM12MFD TRUSS1'-0"1267 7/16"MFD TRUSS1'-0"1267 7/16"2x8 JOISTS5/4" DECKING(2) 2x8DROPPED BEAMPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADESET ON 10" THICKPOURED CONC. WALLCONC. SIDEWALKTOP OF THRESHOLDTO TOP OF JOIST6-1/4" FROM8"5'-4"CANT.JOISTS9'-1 1/8" 10'-3 7/8"CONC WALL9'-8 3/4" 8'-2"8'-1 1/8"3/4" 250 SUBFLOOR3/4" 350 SUBFLOOR8'-4" POURED3 1/2" CONC. FLOORKITCHENOWNERSBATHOWNERSENTRYW.I.C.BATH #2W.I.C.HAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM4) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATAFLAT FRAME FORLIGHTING FIXTURE1'-0"18" MFD FLOOR TRUSSES14" MFD I-JOISTS6'-8"MIN HEADROOM 6'-8"MIN HEADROOM 14" DROPPED BEAMRIPPED RIM BOARD9'-11 3/8" 10"BEDROOMROOMFAMILYROOMFAMILY These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C8XJORDAN-5470-A3.2PC#637: 8-15-2019-CFPC#666: 9-25-2019-CFPERMIT/CONSTRUCT: 4-8-20-LLATTIC VENTILATIONHOUSE: 1633 SQ. FT.391.92 NET FREE VENT NEEDED AT RIDGE50' (LIN. FT. RIDGE VENT) X 18 SQ. IN. (PER LIN. FT) = 900 PROVIDEDFULLY VENTED SOFFITSVENT 1/300th OF ROOF AREA50% TO 80% NEAR RIDGEREMAINDER IN SOFFITPER IRC SECTION R806391.92 NET FREE VENT NEEDED AT SOFFITGARAGE: 506 SQ. FT.121.44 NET FREE VENT NEEDED AT RIDGE14' (LIN. FT. RIDGE VENT) X 18 SQ. IN. (PER LIN. FT) = 252 PROVIDEDFULLY VENTED SOFFITS121.44 NET FREE VENT NEEDED AT SOFFIT9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-2"8'-1 1/8"3/4" SUBFLOOR3/4" SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR18" MFD FLOOR TRUSSES14" MFD I-JOISTSGARAGE4" CONC. FLOOR1/4"=1'-0"LONGITUDINAL SECTION E-E30'-6"BEDRM #31'-0"81211'-6 1/2"18'-11 1/2"19'-6"FOYERSTUDYBEDRM #4DROP PLATES 10"AT 2-CAR PORTION OF GARAGE10"9 7/16"HEEL W.I.C.9'-11 3/8"3/4" RIGID INSUL.MIN. R-30 BATT. INSUL.GARAGE SLAB LEDGE DETAIL1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"THE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.5/8" GYP. BD.DROPPED BEAM SEE LP OR2-PLY 24" VERSALAM BEAM10"14" MFD I-JOISTS2'-0"1'-2"(BOISE-EWP ONLY)BOISE PLANS FOR SIZETYPICAL WALL SECTION1/2"=1'-0"9'-1 1/8"TRUSSES PER PLAN3/4" SUBFLOORVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESAIR CH U T ES APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806EXT. SPRAY-ON WATERPROOFINGWATCH DOG + ENERGY SYSTEMTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINUOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ SILL SEALERMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.JOISTS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTED1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEFINISHED GRADEWILL VARYJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALL(SEE OSWELL ENGINEERING)R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=203.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTRUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTERALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTURE(IF REQUIRED PER FOUNDATIONEXTEND OVER SILL PLATER-5 RIGID INSULATION(AT RIGHT AND LEFT SIDEOF HOME ONLY)SEALED AND TAPED AT TOPCALCULATIONS, R402.2.8.A)R-5 RIGID INSULATION(AT SIDE LOOKOUT FOUNDATION ONLY,NOT AT REAR LOOKOUT WALLS)R-5 RIGID INSULATION-ON INSIDETAPE & SEAL AT TOPFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEDRAINTILE AT WALKOUT WALLS(HILLCREST ONLY)W/ R-10 DRAINAGE BOARDROLL-ON WATERPROOFINGWALL EDGE, ACROSS THE TOP, ANDEXTEND FROM TOP INTERIOR6" DOWN THE EXTERIOR WALL FACELIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLE14" TO TOP OF STONE VENEER 1"=1'-0"WALL DETAILLOOKOUT FINISH2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/2"=1'-0"FLOOR DETAILDENSE PACK FIBERGLASS3/4" SUBFLOOR6" ROUND DUCTWORKMANUFACTURED I-JOISTSR-8 INSULATION WRAPNETR-30 SPRAY FOAM INSUL.4.34" AROUND DUCTWORK(R-6.9 PER INCH)BLOWN-IN INSULATION1" CLOSED-CELLSPRAY FOAM5/8" GYP. BD. FOUNDATION DETAILAT FOOTING STEP LOCATIONS1F1DescriptionDateRevisionProject Number:Date:F11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20200.0011-1-202020 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2F1WALL SECTIONLOOKOUT WALL CONDITION3F1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4F1WALL SECTIONFULL HEIGHT WALL CONDITION5F1REBAR TABLE6F1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2020©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4x4'-0" HOOKS @ 24" O.C. BENT ORDRILLED AND EPOXY GROUTED3'-0"1'-0 " NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT) CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETE STRIPFOOTING PER CODE OR BY BUILDINGDESIGNER, AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN AT LEFT8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/F1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/F2FLOOR TO SILLCONNECTION SEE 1/F2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSGENERAL STRIP FOOTING SIZE GUIDEONE-STORYSTRUCTURE16" WIDE x 8" THICK20" WIDE x 8" THICKTWO-STORYSTRUCTURE20" WIDE x 8" THICK26" WIDE x 8" THICK2000 PSFSOIL1500 PSFNOTE: TABLE ABOVE IS A GENERAL FOOTING SIZE GUIDE THAT SHOULD BE VERIFIED BY HOMEDESIGNER AND IS BASED ON 25'-0" FLOOR SPANS & 50'-0" ROOF SPANSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERS#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2020.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2020©DescriptionDateRevisionJanuary 1, 2020Project Number:Date:0.001F22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1F2BRICK LEDGE INFO5F2WALL SECTIONAT WINDOW WELL LOCATIONS6F2STOOP INFO7F2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2F2BLOCKING DETAILFLOOR JOIST CONDITION3F2BLOCKING DETAILFLOOR TRUSS CONDITION4F2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/F1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/F1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/F1 OR 3/F1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/F1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/F2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/F1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED,12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/A10'-0" MAX TO T.O.S. 1'-8" MAX FLASHING & WOODPROTECTION BYOTHERSFLOOR FRAMING ORBLOCKINGFLOORCONNECTIONSEE 1/F2 &2/F2C.I.P. CONCRETEWALL SEEADJACENTPLANS FORTHICKNESS &MAXIMUM WALLLENGTHSSEE FULLHEIGHT WALLSECTION 5/F1FORREINFORCINGSTOOPSLAB BYOTHERS13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL3'-0" FULL HEIGHT BASEMENTMIN FULL HEIGHT FULL HEIGHT EXAMPLE CORNEROR STRAIGHT WALLOPTIONS -TYPSTOOP AREA8" MIN C.I.P. CONCRETEWALL SEE FULL HEIGHTWALL SECTION 5/F1NOTES:1.ADD RETURN WALLS OR BUTTRESSES IN STOOP AREA AS SHOWN IF OVERALL STOOP CENTER TO CENTERWIDTH EXCEEDS DIMENSIONS SHOWN.2.STOOP WALLS REQUIRE MINIMUM 16" WIDE x 8" DEEP CONCRETE STRIP FOOTING.EXAMPLE '1'EXAMPLE '2'EXAMPLE '3'SLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.TYP * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERBACKFILL BELOWEXTERIOR STOOP SLABSWITH COMPACTEDGRANULAR MATERIALTO FROST DEPTH(4'-0" MINIMUM)NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-8" MAX 2'-6" MIN OPENING 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/F1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/F1LOOKOUTWALLSEE 3/F1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.A SECTION AD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 12' 0" 2B3 3 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 3B4 2 Beam by others 6' 0" 1B5 1 Beam by others 4' 0" 1Pt1 1 3-1/2" x 5-1/2" VERSA-LAM® 1.8 2750 SP 8' 0" 1Pt2 1 5-1/4" x 5-1/4" VERSA-LAM® 1.8 2750 SP 8' 0" 1OPTIONAL EGRESSWINDOW HEADER(2) 1-3/4"X7-1/4"X6'VERSA LAM LVLSTAIRWAYUNEXCAVATEDFLOOR TRUSSESBY OTHERSPORCH FRAMINGBY OTHERSPt2Pt1B1B3B2B5B4B44' 0" 10' 0" 35' 0" 49' 0" 24' 0" 25' 0" 19' 0"11' 6"19' 6"50' 0"4' 6"12' 0" 11' 0"19' 6"2' 0" ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 2 Beam by others 6' 0" 1B2B1B250' 0"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 1 Beam by others 8' 0" 1B3 1 Beam by others 4' 0" 1B2B1B350' 0"Sheet: 1 of 3DWG: Basement BeamsFile: Plan #5470-A3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-1-18AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5470-A3-GLD.R. HORTONMAIN FLOOR FRAMINGDESIGN = L/480BASE MODELMAIN FLOOR FRAMINGWALKOUT OPTIONLOOKOUT OPTIONDETAIL N/A ProductsPlotID Net Qty ProductLength PliesJ1 11 14" BCI® 4500s-1.8 36' 0" 1J2 10 14" BCI® 4500s-1.8 26' 0" 1J3 10 14" BCI® 4500s-1.8 18' 0" 1J4 11 14" BCI® 4500s-1.8 12' 0" 1J5 2 14" BCI® 4500s-1.8 8' 0" 1B1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2B2 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B3 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B4 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 2B5 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 12' 0" 2B6 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 10' 0" 2B7 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 6' 0" 1B8 2 1-3/4" x 24" VERSA-LAM® 2.0 3100 SP 18' 0" 2B9 3 Beam by others 8' 0" 1B10 1 Beam by others 6' 0" 1B11 7 Beam by others 4' 0" 1Ca1 16 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1Bk1 1 14" BCI® 4500s-1.8 11' 0" 1Pt1 1 5-1/4" x 5-1/4" VERSA-LAM® 1.8 2750 SP 10' 0" 1Pt2 1 5-1/4" x 7" VERSA-LAM® 1.8 2750 SP 12' 0" 1Pt3 2 Post by others 8' 0" 1Connector SummaryPlotID Qty Manuf ProductH1 1 Simpson HU11H2 1 Simpson HUCQ412-SDS2.5H3 17 Simpson IUS1.81/14STAIRWAYPORCHGARAGESTART FRAMING HEREJOISTS @ 19.2" OCSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSTART FRAMING HEREFOR JOISTS OVERGARAGE @ 19.2" OCSINGLETRIMMERSOPTIONAL 6 FTWIDE WINDOW"BEAM BY OTHERS"Pt1Pt2Pt3Pt3B4B3B9B11B11B2B11B11B11B2B11B11B9B9B7B6B7B10B5B8B1Ca1Ca1Ca1Ca1Ca1Ca1Ca1J1J3J5J2H2H2Ca1Ca1J4Bk1H3H1H24' 0" 10' 0" 35' 0" 49' 0" 24' 0" 25' 0" 19' 0"11' 6"19' 6"50' 0"1' 0" ProductsPlotID Net Qty Product Length PliesB1 1 Beam by others 4' 0" 1EXISTINGPANTRYHEADERSINGLETRIMMERSB135' 0" 49' 0" Sheet: 2 of 3DWG: Upper Floor FramingFile: Plan #5470-A3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-7-19AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5470-A3-GLD.R. HORTONUPPER FLOOR FRAMINGDESIGN = L/480BASE MODELUPPER FLOOR FRAMINGDETAIL N/AOPTIONAL PANTRY ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B2 1 Girder Truss by others 12' 0" 1B3 2 Beam by others 8' 0" 1B4 4 Beam by others 4' 0" 1PORCH ROOFGARAGE ROOFSTAIRWAYSINGLETRIMMERSSINGLETRIMMERSB1B4B3B4B4B3B1B4B26' 0" 35' 0" 41' 0" 16' 0" 25' 0" 19' 0"12' 0"19' 0"50' 0"Sheet: 3 of 3DWG: Upper Floor HeadersFile: Plan #5470-A3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.Revisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5470-A3-GLD.R. HORTONUPPER FLOOR HEADERSDESIGN = L/360BASE MODELUPPER FLOOR HEADERSDETAIL N/A 2#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#06*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;619#.-176(170&#6+1056*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;61.11-176(170&#6+105/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0722'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#0%12;4+)*6*#0510)4172..%‹&GUETKRVKQP&CVG4GXKUKQP(GDTWCT[2TQLGEV0WODGT&CVG55JGGVUQH2TKPV0COG5KIPGF.KEGPUG0WODGT4[CP/CEMÄÄ&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC&4*QTVQP-GPDTKFIG%QWTV.CMGXKNNG/0Ä#Ä)./QFGN/KPPGUQVC%QPUVTWEVKQP-KNOGT.CPG05WKVG2N[OQWVJ/06GNÄÄYYYJCPUQPITQWROPEQOZ$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;+06'4+14$'#4+0)9#..+06'4+14010Ä$'#4+0)9#..2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'³/#+09+0&(14%'4'5+56+0)5;56'/´(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)4172ž5&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&#4&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;1760#+.'#%*64755616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. 5+/2510#(4#/+0)#0).''#%*'0&  ŒZ0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 (.11464755'5 &'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..411(64755(#56'0'&612.#6'5YF61'0#+.5"1%0#+.4+/6122.#6'5YF61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+..#&&'464755616122.#6'5YF0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y  F0#+.5'8'4;411(64755'5(#56'0'&612.#6'5Y  F61'0#+.5 5+/2510*%.+2Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+.'#%*64755616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+$$10$4#%'64755Y  F0#+.5'8'4;(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4 Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; ':6'4+14$'#4+0)9#..4'24'5'065(+)74'4  +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'&#61%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'&#55*190+06*'&'6#+.5*''65 /+0.'0)6* /+0.'0)6* +0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19 /+0.'0)6* 5%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14&#0%'9+6*6*+5&1%7/'0656#0&#4&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä5($#Z567&552#%'&"1%$/+09#..5*'#6*+0)(+$'4$1#4&5*'#6*+0)Y)#.8#0+<'&411(0#+.514F0#+.514)#7)'56#2.'5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'57221465016'&15$':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#Z567&552#%'&"1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF0#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)%#/+0+/7/Ä+0%*911&5647%674#.2#0'.%140'44'67405*#..$'2418+&'&#6$16*'0&51(#%106+07175.;Ä5*'#6*'&$4#%'&9#...+0'+0#%%14&#0%'9+6*(+)74'4+0.+'71(6*'%140'44'6740#6+'Ä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Ä%'06'4ž%#.+(140+#%140'45ž1464#&+6+10#.%140'45#4'#%%'26#$.'2418+&'&(7..*'+)*65#90$.1%-+0)567&+5&+4'%6.;$'*+0&(.#62146+101(567&5(#56'0'&61)'6*'4+0#5+/+.#4(#5*+10/#6'4+#.59#..567&5 ž14.'55 52(567&)4#&'14$'66'49#..567&5 18'4ž 52(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'52.#055*190.+)*6+0$#%-)4170&#4'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)4172ž5&'5+)0.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*':2$%1&'/+00'516#4'5+&'06+#.%1&'%105647%62146#.(4#/'#55*190+0515$ Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 $4#%'&9#...+0' Ä(6 Ä(6 Ä(6 $4#%'&9#...+0'žÄžÄ01661':%''&žÄ(#56'06122.#6'61*'#&'4Y  4195F5+0-'40#+.5"1%  Z$'#4+0)567&   Z(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0žÄ(41/%'06'41(9#..*'+)*6#54'3ž& Z51.+&$.1%-+0)4'37+4'&#65*'#6*+0),1+06  Z$'#4+0)567&5/+0 8'4+(;Y5722.+'4 5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+105 (170&#6+109#..$'.19.'0)6*1(%106+07175*'#&'4Œ#0%*14$1.6 /+0'/$'& YZZ2.#6'9#5*'40#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y  4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1% 5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55 (#56'0-+0)567&61*'#&'4Y  4195F5+0-'40#+.5"1%žÄ5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.%106+07175.8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3ž& 2418+&'Z+0(+..9#..#$18'*'#&'4#54'3ž&.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&#4&0#+.+0)2418+&'(#56'0+0)1(#$18'(4#/+0)'37#.616*#6&'6#+.'&(14$4#%'&9#..2#0'.52156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.Œ5+/25106+6'0*&41&%172.'4Y'/$'&+061%10%4'6'Œ6*4'#&'&41&Y076 9#5*'4#6*1.&190'0&5+/2510*66*1.&190#0%*140#+.'&61&17$.'567&5(.1145;56'/%10%4'6'(170&#6+10$'.19#.6'40#6'*1.&190#.6'40#6'4#+5'&*1.&190%10%4'6'(170&#6+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*1900#+.'&61&17$.'567&5YŒZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*14+061%10%4'6' DRH 5470 North HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing & Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Tuesday, October 17, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 5470 North Plymouth, MN 55447 Page 2 Project Report General Project Information Project Title:DRH 5470 North Designed By:Michael Hoium Project Date:Tuesday, October 17, 2017 Client Name:DR Horton Client City:Lakeville, MN Company Name:Sabre Plumbing & Heating Company Representative:Michael Hoium Company Address:15535 Medina Road Company City:Plymouth, MN 55447 Company Phone:763-473-2267 Company Fax:763-473-8565 Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -12.38 n/a 30%72 29.40 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:1,123 CFM Per Square ft.:0.254 Square ft. of Room Area:4,426 Square ft. Per Ton:1,690 Volume (ft³):36,831 Building Loads Total Heating Required Including Ventilation Air:60,344 Btuh 60.344 MBH Total Sensible Gain:24,996 Btuh 80 % Total Latent Gain:6,439 Btuh 20 % Total Cooling Required Including Ventilation Air:31,435 Btuh 2.62 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Tuesday, October 17, 2017, 10:11 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 5470 North Plymouth, MN 55447 Page 3 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.62 1,690 4,426 24,996 6,439 31,435 60,344 716 1,123 1,123 System 1 2.62 1,690 4,426 24,996 6,439 31,435 60,344 716 1,123 1,123 12x16 Ventilation 999 4,177 5,175 6,685 Supply Duct Latent 137 137 Return Duct 27 24 52 184 Humidification 6,854 Zone 1 4,426 23,970 2,101 26,071 46,621 716 1,123 1,123 12x16 1-Basement 1,423 3,671 0 3,671 14,215 218 172 172 2--5 2-Main Floor 1,423 12,900 2,101 15,001 16,542 254 604 604 6--6 3-Second Floor 1,580 7,399 0 7,399 15,865 244 347 347 4--5 Tuesday, October 17, 2017, 10:11 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 5470 North Plymouth, MN 55447 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 SHGC, Window and Patio Door, u-value 0.31, SHGC 0.29 434 11,709 0 7,117 7,117 11J: Door-Metal - Fiberglass Core 37.8 1,972 0 544 544 DRH- R15 8ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-15 board insulation to footing, no interior finish, 8' floor depth 400 2,054 0 202 202 DRH- R15 4ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-15 board insulation to footing, no interior finish, 4' floor depth 96 492 0 48 48 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 3046.2 17,225 0 2,633 2,633 DRH- R10 8ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-10 board insulation to footing, no interior finish, 8' floor depth 400 2,053 0 203 203 RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 Closed Cell Spray Foam 534 2,322 0 654 654 R49 16B-49: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles 1580 3,162 0 1,744 1,744 21A-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 1423 3,343 0 0 0 P-32 R-32: Floor-Over open crawl space or garage, Custom, R-30 Blanket insulation, 3/4" Foamboard R- 2, any cover 222 579 0 53 53 Subtotals for structure:44,911 0 13,198 13,198 People:6 1,200 1,380 2,580 Equipment:901 3,638 4,539 Lighting:1250 4,263 4,263 Ductwork:1,894 161 392 553 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 180, Summer CFM: 180 6,685 4,177 999 5,175 Humidification (Winter) 18.69 gal/day :6,854 0 0 0 AED Excursion:0 0 1,127 1,127 Total Building Load Totals:60,344 6,439 24,996 31,435 Check Figures Total Building Supply CFM:1,123 CFM Per Square ft.:0.254 Square ft. of Room Area:4,426 Square ft. Per Ton:1,690 Volume (ft³):36,831 Building Loads Total Heating Required Including Ventilation Air:60,344 Btuh 60.344 MBH Total Sensible Gain:24,996 Btuh 80 % Total Latent Gain:6,439 Btuh 20 % Total Cooling Required Including Ventilation Air:31,435 Btuh 2.62 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Tuesday, October 17, 2017, 10:11 AM Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future Location) of Fan: X R-10/R15 X X R-20 X R-20 X R-21 X R-49 X R-49 X R-30 X R-32 X X Not applicable, all ducts located in conditioned space R-8 MECHANICAL SYSTEMS X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:80000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Cfm's Capacity continuous ventilation rate in cfms:4 " round duct OR Location of duct or system: Select Type furnace room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace Combustion Air Select a Type Balanced Ventilation Capacity in CFMS: High: High: Mechanical Ventilation System 98 60%=110 100%=200 NAT GAS R-410A Cooling System Rating or Size SEER or EER 50 Output in Tons:3 Efficiency RESIDENTIAL LOAD CALC 13 Locations of Fans, describe: HEAT LOSS 60,344 HEAT GAIN 24,996 COOLING LOAD 31,435Mineral FiberboardRigid, Extruded PolystyreneRigid, Isocynurate Appliances Model R-value0.30 PROG5042NRH67PV BA13NA036 Rheem Make-up Air Select a Type Building Envelope air Tightness:Duct system air tightness: Ceiling, flat Manufacturer Interior Bryant Domestic Water Heater Heating System NAT GAS Bryant 912SB48080S17 Average U-Factor (excludes skylights and one door) U: 0.31 Heating or Cooling Ducts Outside Conditioned Spaces Bonus room over garage Describe other insulated areas Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Location of duct or system: Ceiling, vaulted Bay Windows or cantilevered areas Rim Joist (1st Floor+) Wall Per R401.3 Building Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor DRHorton MN License Number BC605657 Mailing Address of the Dwelling or Dwelling Unit 8728 188th Street W Choke Cherry Hill 4th Plan ID 5470 North Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Community RADON SYSTEM Interior THERMAL ENVELOPE Either/OR, See Plans For Location Other Please Describe Here Below Entire Slab Total R-Value of all Types of InsulationType: Check All That Apply Non or Not ApplicableFiberglass, BlownFiberglass, Batts Insulation Location Foam, Closed CellFoam Open Cell Total ventilation (intermittent + continuous) rate in cfms: " metal duct195 04/14/2020 X KP