Loading...
HomeMy WebLinkAboutLA163424 PlansEquipment 5239 Edina Industrial Blvd Edina, MN 55439 (612) 888-9599 DOC TITLE: ELEVATION DIAGRAM AUTHOR: COLTON KOCH DATE: 8/1/2018 REVISION: 1 South Elevation West Elevation East Elevation DC Power Optimizers: 27 - SolarEdge P320 DC Power Optimizers 1 - SolarEdge SE7600H-US Single Phase Inverter Panels: 27 - Hanwha Q-Cell PEAK DUO-G5 320W 28' 7' 7' PanelsPanels Panels Panel height above roof surface: 5" 8 12 30' Truss beneath array 30'15'7.5' 7.5' Project: Jason M Halterman Phone: 651-269-7512 Size: 8.64 KW DC/ 7.6 KW AC Location: 16680 Farrago Trail, Farmington, MN 55024 Building Service: 120/240V, 1Ø, 200A Utility: Dakota Electric Account: 200004884789 Incentive: Energy Wise Premise: 96611 Meter: L081204657 Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 08/08/2018gabbott NAME Jason Halterman LOCATION Farmington, MN, 55024 MODULE Q. Cells :Q.PEAK DUO-G5 320 (32mm) DIMENSIONS 66.34" x 39.37" x 1.26" (1,685 x 1,000 x 32mm) DATE 2018-08-01 TOTAL MODULES 27 TOTAL WATTS 8,640 ATTACHMENT PTS 54 Load Assumptions WIND EXPOSURE B WIND SPEED 100 mph GROUND SNOW LOAD 50 psf ATTACHMENT SPACING 4.0 ft Building Details ROOF SLOPE 33 deg BUILDING HEIGHT 25 ft RISK CATEGORY I XR100 SPAN DETAILS (Portrait) Roof Zone Max Span Max Cantilever 1 5' 4"2' 2" 2 5' 4"2' 2" 3 5' 4"2' 2" MAXIMUM REACTION FORCES (Portrait) Roof Zone Down Uplift Lateral 1 230.00 -92.00 133.00 2 230.00 -107.00 133.00 3 230.00 -107.00 133.00 System Weight TOTAL WEIGHT 1301 lbs WEIGHT/ATTACHMENT 24.1 lbs DISTRIBUTED WEIGHT 2.6 psf RACKING WEIGHT 188.4 lbs Project Details Engineering Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 1 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 08/08/2018gabbott Array Details Array Cols Rows Orientation Row Length Cantilever Violations Provided Rails Attachments Clamps Splices A 8 1 PORTRAIT 26' 7.6"1' 4"None 56'[4 x 14']14 18 2 A 3 2 PORTRAIT 10' 0.9"1'None 56'[4 x 14']12 16 0 11' 1" 26' 8" Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 2 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Array Cols Rows Orientation Row Length Cantilever Violations Provided Rails Attachments Clamps Splices B 2 1 PORTRAIT 6' 9.1"1' 5"None 28'[2 x 14']4 6 0 B 4 1 PORTRAIT 13' 4.6"8"None 28'[2 x 14']8 10 0 B 2 1 PORTRAIT 6' 9.1"1' 5"None 28'[2 x 14']4 6 0 B 1 1 PORTRAIT 3' 5.4"9"None 28'[2 x 14']4 4 0 B 4 1 PORTRAIT 13' 4.6"8"None 28'[2 x 14']8 10 0 16' 7" 13' 5" Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 3 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Note: The images displayed in this report are meant to represent one portion of the array. The use of a break line indicates that the array may continue on beyond that point. Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 4 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Splice Detail XR100 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSALFASTENINGOBJECT End Clamp, Plan STOPPERSLEEVE UNIVERSALFASTENINGOBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULEFRAME RAIL UNIVERSALFASTENINGOBJECT STOPPERSLEEVE1” Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 5 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 6 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544 Bill of Materials GROUP PART DESCRIPTION TOTAL QTY RAILS & SPLICES XR-100-168A XR100, Rail 168" (14 Feet) Clear 18 XR-100-SPLC-BD Kit, XR100 Bonded Splice 2 CLAMPS & GROUNDING UFO-CL-001 Kit, 4pcs, Universal Module Clamp 18 UFO-STP-32MM Kit, 4pcs, Stopper Sleeve, 32MM, Clear 8 GD-LUG-003 Kit, 2pcs, Grounding Lug, Low Profile 4 ATTACHMENTS FM-LFT-003 Kit, 4pcs, Slotted L-Foot, Mill 14 FM-SQ-BHW-V2 Kit, 4pcs, Square-Bolt Bonding Attachment Hardware 14 Last updated by colton koch on 2018-08-01 13:52:31 -0700 Page 7 of 7 Jason Halterman PITCHED ROOF 1495 ZEPHYR AVE, HAYWARD, CA 94544