Loading...
HomeMy WebLinkAboutLA179152 17982 Evening Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Model: Date:4/28/2020 Job Address:17982 Evening Lane Description Units Rate Sub-Total Basement: Unfinished 1278 sf 16.50$ 21,087.00$ Finished sf 15.00$ -$ Family/Rec Room ea Bedroom/Office ea Bathroom ea Dwelling: Main Floor 1278 sf 100.26$ 128,132.28$ Second Floor 1741 sf 100.26$ 174,552.66$ Garage: Wood Frame 889 sf 39.72$ 35,311.08$ Masonry sf -$ Porches: Screen/Gazebos/Open sf 30.00$ -$ 3 Season sf 40.00$ -$ 4 Season sf 40.00$ -$ Decks sf 15.00$ -$ Miscellaneous Fireplace (Masonry)ea 3,000.00$ -$ l Fireplace (Zero Clearance)1 ea 1,500.00$ 1,500.00$ Residential Valuation:360,583.02$ Rounded Valuation 361,000$ Mastered Reduction Permit (from Rate Sheet)2,622.75$ 2,622.75$ Plan Review 1,704.79$ 655.69$ Surcharge 180.50$ 180.50$ Sub-Total 4,508.04$ 3,458.94$ Connection Fees SAC Unit 2,485.00$ 2,485.00$ Water Unit 4,100.00$ 4,100.00$ Sewer Unit 825.00$ 825.00$ Sub-Total 7,410.00$ 7,410.00$ Site Fees Landscape Escrow 1 ea 1,000.00$ 1,000.00$ 1,000.00$ Misc Escrow 1 ea 1,000.00$ 1,000.00$ 1,000.00$ Tree Escrow ea 1,000.00$ -$ -$ Sub-Total 2,000.00$ 2,000.00$ Inclusive Permits Plumbing 1 ea 90.00$ 90.00$ 90.00$ Sewer Water 1 ea 90.00$ 90.00$ 90.00$ Mechanical 1 ea 90.00$ 90.00$ 90.00$ Sub-Total 270.00$ 270.00$ Permit Fee Total 14,188.04$ 13,138.94$ Residential Building Permit Fees Worksheet(2015 Data) PERMIT FEES Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/28/2020shutchins Secure door closed until deck isconstructed with a separate permit. 444UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. TemperedTemperedwithin 2' of doorVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.22x30 ATTIC ACCESS4444444 TemperedTemperedWithin 10' ofsleeping roomsCOVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.444444444 Builders Associaton of Minnesota version 101014 Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring Location (or future location) of Fan: Other Please Describe Here x 10/15 x x x 20 x 20 x 21 x 49 x x x x x Not applicable, all ducts located in conditioned space x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe:Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code x Passive Low: Other, describe: x Low: Location of fan(s), describe: Cfm's 4" " round duct OR Flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 38,032 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor Stone Cottage Construction Inc. MN License Number Lakeville17982 Evening Lane BC636874 Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 64,787 Heating Gain Cooling Load Attic Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.30 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.22 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL-50 13ACXN042-230 Model Heating System Natrual Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Seer 200CFM Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 31,386Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML193UH070 Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3 Ton50 Stone Cottage HVAC Load Calculations for Wise-solberg 17982 Evening Lane Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Thursday, April 02, 2020 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Stone Cottage Project Date:Thursday, April 02, 2020 Client Name:Wise-solberg Client Address:17982 Evening Lane Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Southwest Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,454 CFM Per Square ft.:0.338 Square ft. of Room Area:4,297 Square ft. Per Ton:1,232 Volume (ft³) of Cond. Space:36,117 Building Loads Total Heating Required Including Ventilation Air:64,787 Btuh 64.787 MBH Total Sensible Gain:31,386 Btuh 83 % Total Latent Gain:6,646 Btuh 17 % Total Cooling Required Including Ventilation Air:38,032 Btuh 3.17 Tons (Based On Sensible + Latent) 3.49 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 3.17 1,356 4,297 31,386 6,646 38,032 64,787 1,254 1,454 1,454 System 1 Yes 3.17 1,356 4,297 31,386 6,646 38,032 64,787 1,254 1,454 1,454 24x10 Ventilation 340 1,352 1,692 4,550 Zone 1 4,297 31,046 5,294 36,340 60,237 1,254 1,454 1,454 24x10 1-Main Level 1,278 12,406 1,903 14,309 21,275 443 581 581 7--6 2-Upper Level 1,741 13,360 2,525 15,885 22,247 463 626 626 7--6 3-Lower Level 1,278 5,280 866 6,146 16,715 348 247 247 3--6 C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 602 16,759 0 15,926 15,926 11N: Door-Metal - Polystyrene Core 63 1,918 0 529 529 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 3826 21,635 0 3,308 3,308 15B0-15sf-10: Wall-Basement, , R-15 board insulation to floor, no interior finish, 10' floor depth 441 1,611 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1741 3,029 0 1,671 1,671 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1098 2,388 0 0 0 Subtotals for structure:47,340 0 21,434 21,434 People:7 1,400 1,610 3,010 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 139, Summer CFM: 72 12,897 1,394 1,002 2,396 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 Total Building Load Totals:64,787 6,646 31,386 38,032 Check Figures Total Building Supply CFM:1,454 CFM Per Square ft.:0.338 Square ft. of Room Area:4,297 Square ft. Per Ton:1,232 Volume (ft³) of Cond. Space:36,117 Building Loads Total Heating Required Including Ventilation Air:64,787 Btuh 64.787 MBH Total Sensible Gain:31,386 Btuh 83 % Total Latent Gain:6,646 Btuh 17 % Total Cooling Required Including Ventilation Air:38,032 Btuh 3.17 Tons (Based On Sensible + Latent) 3.49 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 5 Building Pie Chart Building Loss 64,787 Btuh Floor 4%Roof 5% Wall 36% Glass 26% Door 3% Infiltration 20% Ventilation 7% Building Gain 38,032 Btuh Roof 4% Wall 9% Glass 42% Door 1% People 8% Equipment 25% Infiltration 6% Ventilation 4% C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 6 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 602 16,759 0 15,926 15,926 11N: Door-Metal - Polystyrene Core 63 1,918 0 529 529 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 3826 21,635 0 3,308 3,308 15B0-15sf-10: Wall-Basement, , R-15 board insulation to floor, no interior finish, 10' floor depth 441 1,611 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1741 3,029 0 1,671 1,671 21A-24: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24' wide 1098 2,388 0 0 0 Subtotals for structure:47,340 0 21,434 21,434 People:7 1,400 1,610 3,010 Equipment:2,500 7,000 9,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 139, Summer CFM: 72 12,897 1,394 1,002 2,396 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 System 1 Whole House Load Totals:64,787 6,646 31,386 38,032 Check Figures Supply CFM:1,454 CFM Per Square ft.:0.338 Square ft. of Room Area:4,297 Square ft. Per Ton:1,232 Volume (ft³) of Cond. Space:36,117 System Loads Total Heating Required Including Ventilation Air:64,787 Btuh 64.787 MBH Total Sensible Gain:31,386 Btuh 83 % Total Latent Gain:6,646 Btuh 17 % Total Cooling Required Including Ventilation Air:38,032 Btuh 3.17 Tons (Based On Sensible + Latent) 3.49 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 7 Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,278.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,278.0 sq.ft.Supply Air:581 CFM Ceiling Height:8.0 ft.Supply Air Changes:3.4 AC/hr Volume:10,224.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:7 Actual Winter Vent.:49 CFM Runout Air:83 CFM Percent of Supply.:9 % Runout Duct Size:6 in.Actual Summer Vent.:28 CFM Runout Air Velocity:423 ft./min.Percent of Supply:5 % Runout Air Velocity:423 ft./min.Actual Winter Infil.:50 CFM Actual Loss:0.112 in.wg./100 ft.Actual Summer Infil.:26 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SW-Wall-12F-0sw 49 X 9 356 0.065 5.7 2,013 0.9 0 308 NE-Wall-12F-0sw 49 X 9 300 0.065 5.7 1,696 0.9 0 259 SE-Wall-12F-0sw 41 X 9 315 0.065 5.7 1,781 0.9 0 272 NW-Wall-12F-0sw 41 X 9 320 0.065 5.7 1,810 0.9 0 277 SW-Door-11N 6 X 7 42 0.350 30.5 1,279 8.4 0 353 SE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 SW-Gls-4A-1a-o shgc-0.33 0%S 43 0.320 27.8 1,197 31.0 0 1,332 NE-Gls-4A-1a-o shgc-0.33 0%S 141 0.320 27.8 3,925 24.1 0 3,403 SE-Gls-4A-1a-o shgc-0.33 0%S 33 0.320 27.8 919 31.0 0 1,022 NW-Gls-4A-1a-o shgc-0.33 0%S 49 0.320 27.8 1,364 24.1 0 1,183 Subtotals for Structure:16,623 0 8,585 Infil.: Win.: 50.1, Sum.: 26.1 1,620 2.872 4,652 0.223 503 361 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:1,000 3,000 Room Totals:21,275 1,903 12,406 C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 8 Detailed Room Loads - Room 2 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,741.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,741.0 sq.ft.Supply Air:626 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.4 AC/hr Volume:15,669.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:7 Actual Winter Vent.:52 CFM Runout Air:89 CFM Percent of Supply.:8 % Runout Duct Size:6 in.Actual Summer Vent.:30 CFM Runout Air Velocity:455 ft./min.Percent of Supply:5 % Runout Air Velocity:455 ft./min.Actual Winter Infil.:52 CFM Actual Loss:0.130 in.wg./100 ft.Actual Summer Infil.:27 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SW-Wall-12F-0sw 49 X 9 365 0.065 5.7 2,064 0.9 0 316 NE-Wall-12F-0sw 49 X 9 364 0.065 5.7 2,058 0.9 0 315 SE-Wall-12F-0sw 45 X 9 383 0.065 5.7 2,166 0.9 0 331 NW-Wall-12F-0sw 45 X 9 364 0.065 5.7 2,058 0.9 0 315 SW-Gls-4A-1a-o shgc-0.33 0%S 76 0.320 27.8 2,116 31.0 0 2,354 NE-Gls-4A-1a-o shgc-0.33 0%S 77 0.320 27.8 2,144 24.1 0 1,859 SE-Gls-4A-1a-o shgc-0.33 0%S 22 0.320 27.8 612 31.0 0 681 NW-Gls-4A-1a-o shgc-0.33 0%S 41 0.320 27.8 1,141 24.1 0 990 UP-Ceil-16B-50 1741 X 1 1741 0.020 1.7 3,029 1.0 0 1,671 Subtotals for Structure:17,388 0 8,832 Infil.: Win.: 52.3, Sum.: 27.2 1,692 2.872 4,859 0.223 525 378 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 3,000 Room Totals:22,247 2,525 13,360 C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 9 Detailed Room Loads - Room 3 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,278.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,278.0 sq.ft.Supply Air:247 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.5 AC/hr Volume:10,224.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:3 Actual Winter Vent.:39 CFM Runout Air:82 CFM Percent of Supply.:16 % Runout Duct Size:6 in.Actual Summer Vent.:12 CFM Runout Air Velocity:420 ft./min.Percent of Supply:5 % Runout Air Velocity:420 ft./min.Actual Winter Infil.:36 CFM Actual Loss:0.110 in.wg./100 ft.Actual Summer Infil.:19 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain SW-Wall-15B0-15sf-10 49 X 9 441 0.042 3.7 1,611 0.0 0 0 NE-Wall-12F-0sw 49 X 9 384 0.065 5.7 2,172 0.9 0 332 SE-Wall-12F-0sw 41 X 9 339 0.065 5.7 1,917 0.9 0 293 NW-Wall-12F-0sw 41 X 9 336 0.065 5.7 1,900 0.9 0 290 NE-Gls-4A-1a-o shgc-0.33 0%S 57 0.320 27.8 1,587 24.1 0 1,376 SE-Gls-4A-1a-o shgc-0.33 0%S 30 0.320 27.8 835 31.0 0 929 NW-Gls-4A-1a-o shgc-0.33 0%S 33 0.320 27.8 919 24.2 0 797 Floor-21A-24 1 X 1098 1098 0.025 2.2 2,388 0.0 0 0 Subtotals for Structure:13,329 0 4,017 Infil.: Win.: 36.5, Sum.: 19.0 1,179 2.872 3,386 0.223 366 263 Equipment:500 1,000 Room Totals:16,715 866 5,280 C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Stone Cottage Farmington, MN 55024 Page 10 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Main Level 1,278 21,275 443 7-6 423 12,406 1,903 581 581 2 Upper Level 1,741 22,247 463 7-6 455 13,360 2,525 626 626 3 Lower Level 1,278 16,715 348 3-6 420 5,280 866 247 247 Ventilation 4,550 340 1,352 System 1 total 4,297 64,787 1,254 31,386 6,646 1,454 1,454 System 1 Main Trunk Size:24x10 in. Velocity:873 ft./min Loss per 100 ft.:0.106 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:3.17 83% / 17%31,386 6,646 38,032 Recommended:3.49 75% / 25%31,386 10,462 41,848 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\17982 EVENING LAKEVILLE 04022020.rhv Thursday, April 02, 2020, 10:39 AM NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 04/23/2020 X KP