HomeMy WebLinkAboutLA178969 - 16035 Estate Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"128GARAGE PLATE HEIGHT10' - 9 3/8"VINYL BOARD & BATTEN TYP.SEE COLUMN DETAILSHEET A-501ALUMINUM SOFFIT& FASCIA TYP.4:127:12128VINYL LAP SIDING VINYL CORNER TRIM TYP.4 BD. 6" PLANKSSTYLE SHUTTERS 6" BUMPED OUT LOUVERW/ CORBELS3' - 6"CULTURED STONEW/ CONCRETE CAPADDRESS STONE 6" SMARTSIDE FRIEZE BOARD @ FRONT TYP.6" SMARTSIDE STORY BOARD TYP. @ FRONT4" SMARTSIDE WINDOW & DOOR TRIM ALL SIDES THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:30 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-201OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-202 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SECTIONS - ROOF PLANA-502 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/22/2020shutchins
24" RETURNS TYP.8:128:121241277:12ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.7:126:121286:121271271268:128:1224" RETURNS TYP.7:127:1218" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 4:12 & 7:12W/ 6:12 & 8:12 TO MATCH 8:128:128:127:128:124:126:127:127:127 ROOF VENTS REQUIRED 2 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 1 ROOF VENT REQUIRED THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:31 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-202OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit.
20' - 6"10' - 0"0' - 2"18' - 6"30' - 6"49' - 0"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4"0' - 4"*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY45' - 0"2' - 0"1' - 0"5' - 10"19' - 4"6' - 10"38' - 2"17' - 6"24' - 6"42' - 0"7' - 0"2' - 0"21' - 6"23' - 6"23' - 6"47' - 0"24' - 4"22' - 8"15' - 10"6' - 10"17' - 7 1/4"3' - 10 3/4"3' - 10 3/4"12' - 9 1/4"3' - 9 1/2"8' - 1 1/2"30' - 1"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.5' - 3 1/4"16' - 2 3/4"7' - 3 1/4"15' - 4 3/4"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATIONSTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE49' - 0":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.47' - 0"LEAVE A 12" GAP IN THEFOOTING FOR PLUMBING 42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY12' - 9 1/4"11' - 8 3/4"2' - 3 1/4"22' - 0 3/4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:32 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-401OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/4" = 1'-0"A-4011FOUNDATION PLANPFHPFHPFH
UP 16RUNEXCAVATEDFURNACESUMPW. H.15' - 10"6' - 10"20' - 6"10' - 0"18' - 6"30' - 6"49' - 0"38' - 2"6' - 10"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"1' - 0"5' - 10"BEDROOM #523' - 6"23' - 6"21' - 6"2' - 0"SET ON 3X SILL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 19' - 4"22' - 8"2' - 7 1/4"15' - 0"373' x 4' F.G.SHWR W/SURROUND24' VANITY4F. D.MECHANICALBATHUNEXCAVATEDFAMILY ROOM49' - 5"3' - 7"29' - 0"CO DET.SMOKEDET.SMOKEDET.2' - 0"45' - 0"42' - 0"INSULATE BETWEEN WALL & SLAB47' - 0"24' - 4"R & SH. @ 68"17' - 0"10' - 6"6' - 0"11' - 10"6' - 8"21' - 6"16' - 8"62-2x102-9 1/2" LSLFLUSH2-9 1/2" LSL4' - 6"5' - 10"9' - 0"17' - 10"3' - 8"3' - 8"13' - 0"4' - 0"7' - 4"8' - 0"ANCHOR BOLTS ON EACH SIDE OF BEARING POINT ANCHOR BOLTS ON EACH SIDE OF BEARING POINT 7' - 3"1' - 11"7' - 6"21' - 6"4' - 0" B.W.P.4' - 0" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.3-2x6*ALL DIMENSIONS ARE TO OUTSIDE OF THE CONCRETE/ SHEATHING 12" CANT. ABOVE24' - 6"17' - 6"7' - 0"42' - 0"1349' - 0"92' - 8" B.W.P.2-2x102-2x1018" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING47' - 0"2x6AIR EX.STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE3-9 1/2" LVL 2-9 1/2" LSL 4-2x64-2x65x5 PSL5x5 PSLLOADED TO FUTURE DECK1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:32 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-402OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 53944CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES
UP 17RDN 16RDN 3RDN 3R17' - 6"12' - 0"12' - 6"OFFICESINKDW818' - 6"30' - 6"20' - 6"10' - 0"49' - 0"2' - 3"16' - 0"2' - 3"0' - 6"8' - 0"1' - 6"11' - 1"7' - 5"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE11516' - 0"7' - 0"23' - 0"42' - 0"7' - 0"6' - 0"8' - 11"4' - 1"10GARAGE23' - 0"KNEE WALL W/ 14" SPINDLES @ 6' -10" H.H.ABOVE LANDINGR-38 MIN. INSULATIONIN FLOOR ABOVESEE COLUMN DETAILSHEET A-50148' - 0"2' - 0"21' - 6"3' - 0"38' - 0"7' - 0"4' - 6"5' - 10"0' - 10"7' - 10"48' - 0"24" CANT. ABOVE 9' - 9"7' - 9"6' - 0"6' - 0"4' - 9"7' - 9"6' - 0"3' - 6"5' - 0"4' - 0"2' - 4"222MUD ROOMCLOSETPOWDERKITCHENDINING0' - 4 1/2" TYP.GAS F.P.EQEQ611' - 0"12' - 0"21' - 6"16' - 6"5' - 6"0' - 6"1' - 0"PORCHPANTRY0' - 10"10' - 3"24' - 0"1' - 0"23' - 6"23' - 6"GREAT ROOMFOYER12' - 10"3' - 8"3' - 8"17' - 10"999842' - 0"19' - 0"5' - 0"GIRDER TRUSS FLOOR GIRDER OR3-11 7/8" LVL FLUSH2-11 7/8" LSL 2-2x12 2-7 1/4" LSL DROPPED 2-9 1/2" LSL 2-9 1/2" LSL2-2x10 2-9 1/2" LSL CONT. W/2 TRIMMERS EA. SIDE2-9 1/2" LSL2-2x105' - 11 1/4"4' - 2"7' - 2"0' - 10"5' - 2"6' - 0"4' - 10"13' - 2"5x5 PSL5x5 PSL3-2x6 11' - 2"5' - 0"2' - 10"3' - 10"2' - 2"19' - 0"(5) 16" SH.4' - 0" B.W.P.2' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.B.W.P.2' - 10"4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.1' - 6" B.W.P.B.W.P.2' - 3"B.W.P.2' - 3"4' - 0" B.W.P.B.W.P.3' - 10"B.W.P.2' - 6"4' - 0" B.W.P.4' - 0" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2x6GIRDER TRUSS102-14" LVL FLUSH36" GAS COOKTOP 12" FLUSH SANCK BARR & SH. @ 68"PORTAL FRAME W/ HOLD-DOWNS PORTAL FRAME W/ HOLD-DOWNS 2-2x10 FLUSH5' - 0"6' - 2"312' - 8"3' - 10"5' - 6"2-9 1/2" LSLR & SH. @ 68"10"x10" GYP. BD SOFFIT3-2X6KNEE WALL W/14" SPINDLES 9B.W.P.2' - 8"OVEN /MICRO20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING36" REFMFG. ROOF TRUSSES24" O.C.MFG. ROOF TRUSSES24" O.C.MFG. ROOF TRUSSES24" O.C.49' - 0"2'-3" VANITYMFG. ROOF TRUSSES24" O.C.HHUS5.50/102 TRIMMERS LUS28-24-2x64-2x65x5 PSL5x5 PSL2-2x103-2X6CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:33 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-403OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 53944BWP above5x7 PSLThru top plateseach endPFHPFHPFHContinuous tofoundation(TYP)Smoke
DN 17RLOFT42' - 0"8' - 4 1/8"9' - 1 7/8"8' - 10"9' - 2"6' - 6"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.ATTICACCESS12' - 0"7' - 0"23' - 0"436' VANITY6'-3" VANITY2'-6" LINEN23.5:12BEDROOM #4BEDROOM #3CLOSETCLOSETBATHOWNER'SBATHOWNER'SSUITE2240' - 0"2' - 0"39' - 6"0' - 6"2' - 0"42' - 0"KNEE WALL W/14" SPINDLES 17' - 10"3' - 8"3' - 8"14' - 10"4' - 6"5' - 10"31' - 8"12173212323.5:122-2x102-2x102-9 1/2" LSL2-2x102-2x102-2x102-2x102-2x1017' - 6"24' - 6"12' - 0"8' - 9"18' - 9"6' - 0"6' - 0"3' - 5"3' - 7"2' - 6"20' - 6"4' - 3"9' - 6"7' - 9"18' - 6"KNEE WALL W/14" SPINDLES 13' - 2"3' - 0 1/4"5' - 2 3/4"3' - 4"9' - 9"5' - 0"6' - 5"3' - 3 1/4"3' - 1"1' - 8"3' - 3"0' - 11 3/4"4' - 1"2' - 7"12' - 2"15' - 4"4' - 3"2' - 3"3' - 5"3' - 3"3' - 4"10' - 2"12' - 3"3' - 9"2' - 6"11' - 5"5' - 11"6' - 2"3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.SMOKEDET.DRYERWASHER410' - 2"3' - 5"2' - 0"11' - 1"5' - 0"34R & SH. @ 68"25' TUB/SHWR(5) 16" SH.3' - 2"3' - 5"3'x5' TUBSOAKING 23' LINENR & SH. @ 68"R & SH. @ 68"R & SH. @ 68"FAN/LIGHTSMOKEDET.BEDROOM #23' - 0" B.W.P.2x652-2x10 W/ 2 TRIMMERS EA. SIDEVAULT LINE 3-2x6GIRDER TRUSSOWNER'SCLOSET1TILE SHOWER3' - 1"4' - 11 1/2"42' - 0"GIRDER TRUSSLAUNDRYHALLMFG. ROOF TRUSSES24" O.C.MFG. ROOF TRUSSES24" O.C.MFG. ROOF TRUSSES24" O.C.11112-2x102-2x1014CLOSET13' - 6"3-2x65x5 PSL5x5 PSL42' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:33 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-404OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/4" = 1'-0"A-4041UPPER FLOOR PLANWithin 10' of bedroomsTemperedTemperedThru Top plates each end & continuous to foundation each end
1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT 8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:34 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-501OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/2" = 1'-0"A-5012TYP. COLUMN3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5013TYP. WALL SECTION1/2" = 1'-0"A-5014GARAGE CEILINGWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 4 6048 SL 5' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 1 3636 SL 3' - 0" 3' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 4860 PIC 4' - 0" 5' - 0" 12' - 10"5 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 6' - 10"6 WINDSOR NEXT DIMENSION 1 4836 PIC 4' - 0" 3' - 0" 1' - 8 1/4"7 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 2" 2' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 21-42-2160 SL 7' - 0" 5' - 0" 6' - 10"9 WINDSOR NEXT DIMENSION 3 P4260/AR24 T 4' - 0" 7' - 0" 8' - 0"10 WINDSOR NEXT DIMENSION 1 4842 SL 4' - 0" 3' - 6" 6' - 10"11 WINDSOR NEXT DIMENSION 2 2424 AWN FIXED 2' - 0" 2' - 0" 6' - 10"12 WINDSOR NEXT DIMENSION 1 3648 CSMT E 3' - 0" 4' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0"6' - 10"14 WINDSOR NEXT DIMENSION 1 3618 PIC 3' - 0" 1' - 6" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISHCEILINGHEIGHT COMMENTSLOWER FLOOR BEDROOM #5 CARPET 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 8' - 2" .LOWER FLOOR MECHANICAL CONCRETE 8' - 2" MECHANICALS MAY VERYLOWER FLOOR BATH VINYL 8' - 2" .MAIN FLOOR PANTRY . 9' - 1 1/8"MAIN FLOOR OFFICE CARPET 9' - 1 1/8" .MAIN FLOOR GREAT ROOM CARPET 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 9' - 1 1/8" .MAIN FLOOR DINING WOOD 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 9' - 1 1/8" .UPPER FLOOR CLOSET 8' - 1 1/8"UPPER FLOOR LOFT CARPET 8' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 8' - 1 1/8" VAULTEDUPPER FLOOR BEDROOM #2 CARPET 8' - 1 1/8" .UPPER FLOOR OWNER'S CLOSET CARPET 8' - 1 1/8" .UPPER FLOOR HALL CARPET 8' - 1 1/8"UPPER FLOOR BATH VINYL 8' - 1 1/8" .UPPER FLOOR OWNER'S BATH VINYL 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 8' - 1 1/8"DOOR SCHEDULETYP MARK DOOR SIZE COUNT COMMENTS1 2/4 OPG. 12 2/4 x 6/8 113 2/6 x 6/8 54 2/8 x 6/8 55 2/8 x 6/8 FIRE RATED 16 3/0 x 6/8 17 5/0 x 6/8 18 5/0 x 6/8 FULL VIEW 19 6/0 x 6/8 SLIDER 210 8' x 7' O.H. GARAGE DOOR 111 16' x 7' O.H. GARAGE DOOR 1
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESVERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:4/9/2020 11:15:35 AMTHE WARFA RESIDENCEL5, B3 - DODD CROSSING16035 ESTATE LANELAKEVILLE, MN 55044A-502OTT1083.24.20 CB165812899974.9.20 CB2.25.20 CB8'-1 1/8"9'-1 1/8"8'-4"THE MADISON 539441/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. LOOKOUT SECTION1/2" = 1'-0"A-5023TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5024TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5025BEARING WALL SECTION3/8" = 1'-0"A-5026METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS
04/14/2020XKP