HomeMy WebLinkAboutLA179578 17359 Eagleview Dr Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
MAIN FLOOR6' -5 3/8"MAIN PLATE14' -6 1/2"LOWER FLOOR-3' -2 1/2"T.O. FOUNDATION0' -0"LOWER PLATE4' -10 5/8"FOYER FLOOR0' -11 1/2"GARAGE PLATE9' -0 5/8"MAIN FLOOR PLATE HEIGHT8' - 1 1/8"LOWER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT9' - 0 5/8"1261266:12ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING KWP WINDOWTRIM TYP.12" SQUARECEDAR COLUMN ON 18"CULTURED STONE BASECULTURED STONEW/ CONCRETE CAPUPPER FLOOR10' -7 3/8"UPPER PLATE18' -8 1/2"6:126:126:12VINYL SHAKESIDINGUPPER PLATE HEIGHT8' - 1 1/8"FOYER PLATE HEIGHT8' - 1 1/8"3' - 6"5' - 6"6:12ADDRESS STONE1261266:121266:126:121266:12VINYL SIDING& CORNERS TYP.6:12ALUMINUM SOFFIT& FASCIA TYP.KWP WINDOWTRIM TYP. RAILING PER CODE6:12 PITCH STANDARD ENERGY HEELS18" OVERHANGS & 12" RAKES TYP.6:126:126:126:126:126:126:126:129 VENTS @ HOUSE1 VENT@ GARAGE6:126:126:126:126:121/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012LEFT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATESQUARE FEETPROJECTSHEETUPPER:MAIN:BONUS:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:LOWER:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES17645 JUNIPER PATH, SUITE 200, LAKEVILLE MN 55044 PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:FOUND.:4/28/2020 9:08:41 AMTHE RAINWATER RESIDENCE17359 EAGLEVIEW DRIVELAKEVILLE, MN 55024A-201DDB1304.17.20 VL6341217(998)4.27.20 CB4.15.20 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"18511/8" = 1'-0"A-2013RIGHT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATION1/8" = 1'-0"A-2015ROOF PLANSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONS/ ROOF PLANA-401 FOUNDATION/ DETAILSA-402 LOWER FLOOR/ SCHEDULESA-403 MAIN FLOOR/ SCHEDULESConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode05/12/2020dmathews
41' - 10"22' - 8"19' - 2"STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE26' - 8"25' - 0"9' - 2"32' - 8"NOTE:DIMENSIONS ARE TO OUTSIDEOF CONCRETE, NOT INSULATION:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE2' - 0"17' - 2"21' - 8"1' - 0"51' - 10"4' - 10"4' - 4"5' - 0"27' - 8"21' - 4"30' - 6"11' - 0"10' - 4"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 10 1/2"8' - 3" M.O.0' - 10 1/2"0' - 8"9' - 8"0' - 4"0' - 4"13' - 7 1/4"3' - 10 1/2"4' - 8 1/4"5' - 0 3/4"9' - 0 1/2"18' - 6 3/4"2x4 STUDS @ 16" O.C. ONHALF-HIGH 4" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.9' - 2"13' - 6"29' - 6"11' - 2"6' - 2 3/4"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)0' - 2"3'-6"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1' - 3"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY51' - 8"41' - 10"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.Ø12"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY13' - 8 3/4"7' - 11 1/4"11' - 11 1/4"0' - 0 3/4"11' - 6 1/2"15' - 0 3/4"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)Ø14"Ø14"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS3/4" SUBFLOORFLOOR TRUSSESTO BE MFG. W/1 1/2" CANTILEVER2x8 SILL PLATE, ANCHORBOLTS PER CODE8" POUREDFOUNDATION WALL2x6 EXTERIOR WALLWITH 1/2" PLYWOODSHEATHING2" FOAMINSULATION2x6 EXTERIOR WALLWITH 3/4" BILDRITESHEATHING2" FOAMINSULATION2x4 RIBBON ATTACHED TOTOP & BOTTOM CHORDS USING0.135" x 3.50" BOX NAILS @ 6"O.C. THROUGHOUT & 1 NAILINTO EACH WEB3/4" SUBFLOOR2x8 SILL PLATE, ANCHORBOLTS PER CODE8" POUREDFOUNDATION WALL4x2 GABLE TRUSSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS*SET FOUNDATION WALLS IN2" -OUTSIDE OF FOUNDATIONINSULATION TO ALIGN WITHOUTSIDE OF SHEATHING2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADEVERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORMAIN FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION3/4" BILDRITESHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEARCHITECTURAL ASPHALT SHINGLES W/ 15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONSTEEL FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGELOWER FLOOR PLATE HEIGHT8' - 1 1/8"RIM JOISTR-20 SPRAYFOAM INSULATIONWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*SET FOUNDATION WALLS IN2" -OUTSIDE OF FOUNDATIONINSULATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES18" TOP CHORDBEARING FLOOR TRUSSES,SPACING PER MFG.3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" FOAMBOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 6"POUREDFND. WALLTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATESQUARE FEETPROJECTSHEETUPPER:MAIN:BONUS:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:LOWER:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES17645 JUNIPER PATH, SUITE 200, LAKEVILLE MN 55044 PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:FOUND.:4/28/2020 9:08:41 AMTHE RAINWATER RESIDENCE17359 EAGLEVIEW DRIVELAKEVILLE, MN 55024A-401DDB1304.17.20 VL6341217(998)4.27.20 CB4.15.20 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"18511/4" = 1'-0"A-4011FOUNDATION PLAN1/2" = 1'-0"A-4012BEARING WALL SECTION1/2" = 1'-0"A-4013FLOOR TRUSS DETAILS1/2" = 1'-0"A-4014TYP. WALKOUT SECTION1/2" = 1'-0"A-4015TYP. WALL SECTION1/2" = 1'-0"A-4016TYP. HOUSE/GARAGE WALL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:15" min bell diameter for loadsR-4 on pipe in atticUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UP 7R42' - 0"52' - 0"30' - 6"21' - 6"UNEXCAVATED3SUMPFURNACEFLOORDRAINW. H.9' - 0"33' - 0"0' - 6"52' - 0" (BRACED WALL LINE SPACING)AIR EX.STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE10' - 0"20' - 6"10' - 6"11' - 0"28' - 0"5' - 0"4625' VANITY5' TUB/SHWRMECHANICAL6HALLFAMILYROOMCRAWLSPACE7STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITEDECK ABOVETRT'D 2x8'S@ 16" O.C.2-2x10 TRT'D6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)6' - 0"13' - 8"7' - 4"13' - 2"11' - 10"42' - 0"2' - 0"17' - 0" (BRACED WALL LINE SPACING)23' - 0"1' - 0"22' - 0"0' - 6"5' - 6"5' - 6"0' - 10"9' - 8"4' - 10"4' - 2"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.BEDROOM #4/ OFFICEBATH29' - 0 3/4"5' - 4 1/2"6' - 5"5' - 1 3/4"6' - 0"9' - 0"5' - 0"19' - 0"5' - 2 3/4"9' - 0 1/2"18' - 8 3/4"CO DET.SMOKEDET.SMOKEDET.14' - 0"3' - 7 3/4"4' - 4 1/4"2' - 6" B.W.P.5' - 0" B.W.P.7' - 0" B.W.P.7' - 0" B.W.P.3' - 0" B.W.P.6' - 0" B.W.P.3' - 0" B.W.P.4' - 0" B.W.P.27' - 0" (BRACED WALL LINE SPACING)(METHOD G.B.)6' - 0" B.W.P.(METHOD G.B.)6' - 0" B.W.P.2-2x102-2x102-9 1/2" LVLW/ 2 TRIMMERS2-9 1/2" LVLW/ 2 TRIMMERS2-9 1/2" LVL9' - 4"3' - 0"4' - 8"4CLOSETBAR SINKR & SH24" CANT.ABOVE18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING2x10'S@ 16" O.C.21027' - 0"25' - 0"3' - 0" B.W.P.2x6SILL COCKSILL COCKGAS F.P.EQEQ5' - 0"2' - 0"SET FIREPLACEON FINISHED FLOORWET BAR24" CANT.ABOVETRT'D 2x10'S@ 16" O.C.DECK ABOVE0' - 2 3/4"11' - 6 1/2"0' - 2 3/4"12' - 0"0' - 2 3/4"11' - 9 1/4"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)3-2x10 FLUSHFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATESQUARE FEETPROJECTSHEETUPPER:MAIN:BONUS:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:LOWER:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES17645 JUNIPER PATH, SUITE 200, LAKEVILLE MN 55044 PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:FOUND.:4/28/2020 9:08:43 AMTHE RAINWATER RESIDENCE17359 EAGLEVIEW DRIVELAKEVILLE, MN 55024A-402DDB1304.17.20 VL6341217(998)4.27.20 CB4.15.20 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"18513/8" = 1'-0"A-4022METHOD PFH - PORTAL FRAME WITH HOLD-DOWNSWINDOW SCHEDULETYPE MARK MANUFACTURER UNIT COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 MI 3642 SL 1 3' - 0" 3' - 6" 6' - 10"2 MI 6048 SL 4 5' - 0" 4' - 0" 6' - 10"3 MI 6042 SL 2 5' - 0" 3' - 6" 6' - 10"4 MI 7260 SL 2 6' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR CRAWL SPACE 87 SF 3' - 2 1/2"LOWER FLOOR BEDROOM #4 / OFFICE CARPET 132 SF 8' - 1 1/8"LOWER FLOOR HALL CARPET 40 SF 8' - 1 1/8"LOWER FLOOR FAMILY ROOM CARPET 554 SF 8' - 1 1/8"LOWER FLOOR CLOSET CARPET 40 SF 8' - 1 1/8"LOWER FLOOR MECHANICAL CONCRETE 56 SF 8' - 1 1/8"LOWER FLOOR BATH ROLL VINYL 58 SF 8' - 1 1/8"LOWER FLOOR WET BAR ROLL VINYL 33 SF 8' - 1 1/8"FOYER FLOOR GARAGE657 SF 9' - 9 3/8"FOYER FLOOR FOYER WOOD 67 SF 8' - 1 1/8"FOYER FLOOR STOOP WOOD DECK 53 SF 8' - 1 1/8" .MAIN FLOOR BEDROOM #3 CARPET 146 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #2 CARPET 156 SF 8' - 1 1/8"MAIN FLOOR LIVING ROOM CARPET 168 SF 8' - 1 1/8"MAIN FLOOR HALL CARPET 768 SF 8' - 1 1/8"MAIN FLOOR DECK CEDAR 144 SF 8' - 1 1/8"MAIN FLOOR BATH ROLL VINYL 51 SF 8' - 1 1/8"MAIN FLOOR DINING WOOD 159 SF 8' - 1 1/8"MAIN FLOOR KITCHEN WOOD 159 SF 8' - 1 1/8"MAIN FLOOR PANTRY WOOD 33 SF 8' - 1 1/8"UPPER FLOOR OWNER'S SUITE CARPET 201 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR CLOSET CARPET 114 SF 8' - 1 1/8"UPPER FLOOR CLOSET CARPET 31 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY ROLL VINYL 66 SF 8' - 1 1/8"UPPER FLOOR OWNER'S BATH TILE 82 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZE COUNT COMMENTS1 2/0 x 6/8 12 2/0 x 6/8 PKT 13 2/4 OPG 14 2/4 x 6/8 85 2/4 x 6/8 PKT 26 2/6 x 6/8 67 2/8 x 6/8 28 2/8 x 6/8 FIRE RATED 19 3/0 x 6/8 W/ 12" D.S. SL 110 6/0 x 6/8 SLIDER 211 8' x 7' O.H. GARAGE DOOR 112 16' x 7' O.H. GARAGE DOOR 1(3)2x12 min for span
UP 9RDN 7RDN 2RUP 7RDN 2RDN 7R42' - 0"SINKDW11124HALF WALL84" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TOMATCH FOYER PLATE HEIGHT36" REF30" RANGE52' - 0" (BRACED WALL LINE SPACING)1' - 0"22' - 0"644464BEDROOM #3BEDROOM #2R & SHLINENR & SHR & SH4'-6" VANITY22BATHDININGKITCHENPANTRYLIVINGROOMHALLFOYERGARAGE10' - 0"20' - 6"10' - 6"11' - 0"30' - 6" (BRACED WALL LINE SPACING)21' - 6" (BRACED WALL LINE SPACING)52' - 0"40' - 0"23' - 0" (BRACED WALL LINE SPACING)17' - 0" (BRACED WALL LINE SPACING)RAILINGSTOOP6924' - 0"3' - 0"9' - 0"33' - 0"2' - 3"16' - 0"2' - 3"1' - 0"8' - 0"1' - 0"6' - 0"9' - 10 5/8"11' - 1 3/8"8' - 6"10' - 9 3/4"5' - 8 1/4"21' - 5"8' - 7"10' - 10"11' - 2"SMOKEDET.SMOKEDET.3' - 9 1/2"2' - 6"4' - 10 1/2"16' - 0"8' - 0"4' - 0"26' - 0"3' - 3 1/2"5' - 3 1/2"3' - 11"4' - 10 1/2"8' - 2 1/2"2' - 10"5' - 4 1/2"2' - 7"2x63' - 6"6' - 0"14' - 0"3' - 7 3/4"4' - 4 1/4"5' - 6"5' - 6"6' - 7 3/4"4' - 4 1/4"19' - 0"6' - 8"9' - 0"5' - 0"VAULT LINE3:123:124' - 0"5' - 0"5' - 0"5' - 0"5' - 0"6' - 7 5/8"7' - 0"4' - 4 3/8"2' - 4"4' - 0"4' - 0"2' - 6"TYP.0' - 10"CO DET.SMOKEDET.12" SQUARE COLUMN ON18" CULTURED STONE BASESMOKEDET.11' - 0"13' - 0" (BRACED WALL LINE SPACING)27' - 0" (BRACED WALL LINE SPACING)PFH BRACEDWALL PANEL9' - 0" B.W.P.(METHOD G.B.)6' - 0" B.W.P.FIRE ROCK & INSULATEUNDER STAIRS2' - 6" B.W.P.2' - 6" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.3' - 0" B.W.P.6' - 0" B.W.P.3' - 0" B.W.P.4' - 0" B.W.P.6' - 0" B.W.P.4' - 0" B.W.P.2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10 W/2 TRIMMERSFLOORGIRDER2-2x10FLUSH2-2x12 W/ 2 TRIMMERSFLOOR LINE ABOVE2-2x12HANGER3-18" LVL FLUSH2-2x6VERIFY5 1/4" x5 1/4" PSL2-2x82-2x10 W/2 TRIMMERSFLOORLINEABOVE2-2x10 FLUSH16" SH.27' - 0"25' - 0"3' - 0" B.W.P.2' - 0"MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.1016" SH.1HUTCH BY OWNER7'-2" SOFFIT FINISHED HEIGHT (VERIFY)BEAMS ABOVE TOBE SIZED BY OTHERSVERIFYCARPETCARPETCARPETOSB ON THIS WALL5 'JET TUB/F.G.4' - 0"EQEQ2' - 0"7'-2" SOFFIT FINISHED HEIGHT (VERIFY)DECKRAILING PER CODE12' - 0"12' - 0"544653DRYERWASHER6'-6" VANITYTILEDSHOWER347R & SHOWNER'SSUITEOWNER'SBATHCLOSETCLOSETKINGR & SHHALF WALL4'-6"FOLDINGTABLE1 (BRACED WALL LINE SPACING)10' - 6"20' - 6" (BRACED WALL LINE SPACING) (BRACED WALL LINE SPACING)10' - 0"5' - 11"4' - 7"10' - 3"10' - 3"22' - 6"8' - 0"5' - 6"2' - 6 3/4"6' - 5 1/4"11' - 0"4' - 0"26' - 0"2' - 6 1/2"8' - 5 1/2"4' - 3 1/2"3' - 4 3/4"3' - 5 1/2"3' - 5"1' - 10 1/2"3' - 8 1/2"5' - 0"17' - 4"2x65' - 4 1/4"3' - 3 1/2"R & SHSMOKEDET.CO DET.SMOKEDET.R & SH18' - 6" (BRACED WALL LINE SPACING)2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.(METHOD G.B.)4' - 0" B.W.P.(METHOD G.B.)4' - 0" B.W.P.(METHOD G.B.)4' - 0" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.4' - 0" B.W.P.2-2x102-2x10 W/2 TRIMMERSGIRDER TRUSS13' - 6"9' - 0"22' - 6"MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.LAUNDRY41' - 0" (BRACED WALL LINE SPACING)41' - 0"BRACED WALL LINE SPACING8' - 6"BRACED WALL LINE SPACING10' - 0"2' - 0" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2' - 8" B.W.P.2x6HANGING RACKBOX VAULTTYP.2' - 0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF NORTH HOUSE RESIDENTIAL DESIGN. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHERTHAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF NORTH HOUSE RESIDENTIAL DESIGN.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. NORTH HOUSE RESIDENTIAL DESIGN ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY NORTH HOUSE RESIDENTIAL DESIGN OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATESQUARE FEETPROJECTSHEETUPPER:MAIN:BONUS:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5REV. 6PLATE HEIGHTSUPPER:MAIN:LOWER:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES17645 JUNIPER PATH, SUITE 200, LAKEVILLE MN 55044 PH (651) 344-7151FX (651) 344-7152DISTINCTIVEDESIGNBUILDLLC.COMTOTAL:FOUND.:4/28/2020 9:08:45 AMTHE RAINWATER RESIDENCE17359 EAGLEVIEW DRIVELAKEVILLE, MN 55024A-403DDB1304.17.20 VL6341217(998)4.27.20 CB4.15.20 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"18511/4" = 1'-0"A-4032UPPER FLOOR PLANWINDOW SCHEDULETYPE MARK MANUFACTURER UNIT COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 MI 3642 SL 1 3' - 0" 3' - 6" 6' - 10"2 MI 6048 SL 4 5' - 0" 4' - 0" 6' - 10"3 MI 6042 SL 2 5' - 0" 3' - 6" 6' - 10"4 MI 7260 SL 2 6' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR CRAWL SPACE 87 SF 3' - 2 1/2"LOWER FLOOR BEDROOM #4 / OFFICE CARPET 132 SF 8' - 1 1/8"LOWER FLOOR HALL CARPET 40 SF 8' - 1 1/8"LOWER FLOOR FAMILY ROOM CARPET 554 SF 8' - 1 1/8"LOWER FLOOR CLOSET CARPET 40 SF 8' - 1 1/8"LOWER FLOOR MECHANICAL CONCRETE 56 SF 8' - 1 1/8"LOWER FLOOR BATH ROLL VINYL 58 SF 8' - 1 1/8"LOWER FLOOR WET BAR ROLL VINYL 33 SF 8' - 1 1/8"FOYER FLOOR GARAGE657 SF 9' - 9 3/8"FOYER FLOOR FOYER WOOD 67 SF 8' - 1 1/8"FOYER FLOOR STOOP WOOD DECK 53 SF 8' - 1 1/8" .MAIN FLOOR BEDROOM #3 CARPET 146 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #2 CARPET 156 SF 8' - 1 1/8"MAIN FLOOR LIVING ROOM CARPET 168 SF 8' - 1 1/8"MAIN FLOOR HALL CARPET 768 SF 8' - 1 1/8"MAIN FLOOR DECK CEDAR 144 SF 8' - 1 1/8"MAIN FLOOR BATH ROLL VINYL 51 SF 8' - 1 1/8"MAIN FLOOR DINING WOOD 159 SF 8' - 1 1/8"MAIN FLOOR KITCHEN WOOD 159 SF 8' - 1 1/8"MAIN FLOOR PANTRY WOOD 33 SF 8' - 1 1/8"UPPER FLOOR OWNER'S SUITE CARPET 201 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR CLOSET CARPET 114 SF 8' - 1 1/8"UPPER FLOOR CLOSET CARPET 31 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY ROLL VINYL 66 SF 8' - 1 1/8"UPPER FLOOR OWNER'S BATH TILE 82 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZE COUNT COMMENTS1 2/0 x 6/8 12 2/0 x 6/8 PKT 13 2/4 OPG 14 2/4 x 6/8 85 2/4 x 6/8 PKT 26 2/6 x 6/8 67 2/8 x 6/8 28 2/8 x 6/8 FIRE RATED 19 3/0 x 6/8 W/ 12" D.S. SL 110 6/0 x 6/8 SLIDER 211 8' x 7' O.H. GARAGE DOOR 112 16' x 7' O.H. GARAGE DOOR 1FANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWP AboveBWPs AboveGirder Trusses5-1/2" Paralam5-1/2" Paralam
05/01/2020 X
KP