Loading...
HomeMy WebLinkAboutLA179518 PlansMust be #1 SP per engineers design of notching joists to sit on house foundation. 18" minimum bell, use B footing. Verify spacing requirement for specific composite decking if used. Products like Azek or Ultra Deck have maximum stringer spacing of 9" o.c. Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 05/20/2020dmathews Date: May 19, 2020 To: Bischel Building 100 8th St. Farmington, MN 55024 Attn: Mike Bischel From: Eric Bunkers Project: Residence 21285 Inspiration Ct. Lakeville, MN 55044 Proj. No: 20086 Subject: Proposed Deck Joist Notch Dear Mike: As requested, we designed new structural members for the above referenced project. We have designed the new members using a floor dead load of 15 psf and a floor live load of 40 psf in accordance with the Minnesota State Building Code. Our work only includes designing the new members as shown at the above reference project and is based on drawings provided by you and from our conversations. Attached are 2 structural sheets with annotated framing notes showing the new members and connections. All framing shall be shored and temporarily braced as required by the contractor and all minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber shall be minimum #2 SPF with treated lumber to be #1 S. Pine. Our calculations assume all lumber is of good quality and does not have large splits and checks and shall be visually inspected by the contractor at the time of construction. All fasteners in contact with treated lumber shall be G185 hot dipped galvanized or equal. The existing framing is assumed to be in good condition and performing adequately. The existing footings have been assumed to be typical spread footings on good soils that are assumed to be performing adequately. The contractor shall also verify the condition of structural members and foundations affected by the remodeling. New finish cracks in existing walls and ceilings are likely and common in remodel construction. When installed as indicated above, the new framing members shown on the attached sheets shall support the loads as required in accordance with the Minnesota State Building Code. If you have any questions or concerns, please feel free to contact us. Sincerely, Bunkers and Associates, LLC Eric M. Bunkers, P.E. MN Reg. Num. 26490 I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Eric M. Bunkers Date: May 19, 2020 Reg. No. 26490